Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23.056
Filter
1.
Circ Cardiovasc Imaging ; 17(5): e016267, 2024 May.
Article in English | MEDLINE | ID: mdl-38771899

ABSTRACT

BACKGROUND: Aortic valve calcification (AVC) indexation to the aortic annulus (AA) area measured by Doppler echocardiography (AVCdEcho) provides powerful prognostic information in patients with aortic stenosis (AS). However, the indexation by AA measured by multidetector computed tomography (AVCdCT) has never been evaluated. The aim of this study was to compare AVC, AVCdCT, and AVCdEcho with regard to hemodynamic correlations and clinical outcomes in patients with AS. METHODS: Data from 889 patients, mainly White, with calcific AS who underwent Doppler echocardiography and multidetector computed tomography within the same episode of care were retrospectively analyzed. AA was measured both by Doppler echocardiography and multidetector computed tomography. AVCdCT severity thresholds were established using receiver operating characteristic curve analyses in men and women separately. The primary end point was the occurrence of all-cause mortality. RESULTS: Correlations between gradient/velocity and AVCd were stronger (both P≤0.005) using AVCdCT (r=0.68, P<0.001 and r=0.66, P<0.001) than AVC (r=0.61, P<0.001 and r=0.60, P<0.001) or AVCdEcho (r=0.61, P<0.001 and r=0.59, P<0.001). AVCdCT thresholds for the identification of severe AS were 334 Agatston units (AU)/cm2 for women and 467 AU/cm2 for men. On a median follow-up of 6.62 (6.19-9.69) years, AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict all-cause mortality in multivariate analyses (hazard ratio [HR], 1.59 [95% CI, 1.26-2.00]; P<0.001 versus HR, 1.53 [95% CI, 1.11-1.65]; P=0.003 versus HR, 1.27 [95% CI, 1.11-1.46]; P<0.001; all likelihood test P≤0.004). AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict survival under medical treatment in multivariate analyses (HR, 1.80 [95% CI, 1.27-1.58]; P<0.001 compared with HR, 1.55 [95% CI, 1.13-2.10]; P=0.007; HR, 1.28 [95% CI, 1.03-1.57]; P=0.01; all likelihood test P<0.03). AVCdCT ratio predicts mortality in all subgroups of patients with AS. CONCLUSIONS: AVCdCT appears to be equivalent or superior to AVC and AVCdEcho to assess AS severity and predict all-cause mortality. Thus, it should be used to evaluate AS severity in patients with nonconclusive echocardiographic evaluations with or without low-flow status. AVCdCT thresholds of 300 AU/cm2 for women and 500 AU/cm2 for men seem to be appropriate to identify severe AS. Further studies are needed to validate these thresholds, especially in diverse populations.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Calcinosis , Echocardiography, Doppler , Multidetector Computed Tomography , Predictive Value of Tests , Severity of Illness Index , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Male , Female , Multidetector Computed Tomography/methods , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Retrospective Studies , Aged , Calcinosis/diagnostic imaging , Calcinosis/physiopathology , Calcinosis/mortality , Echocardiography, Doppler/methods , Aged, 80 and over , Prognosis , ROC Curve , Hemodynamics , Middle Aged , Risk Factors
2.
Echocardiography ; 41(5): e15835, 2024 May.
Article in English | MEDLINE | ID: mdl-38784978

ABSTRACT

PURPOSE: There is currently limited information on the utility of transthoracic echocardiography (TTE)-derived Doppler parameters for assessing bioprosthetic tricuspid valve (BTV) dysfunction. Our study aimed to establish the precision and appropriate reference ranges for routinely collected transthoracic Doppler parameters in the assessment of BTV dysfunction. METHODS: We retrospectively evaluated 100 BTV patients who underwent TTE. Based on redo surgical confirmation or more than 2 repeat TTE or transesophageal echocardiography (TEE) examinations, patients were allocated to normal (n = 61), regurgitant (n = 24), or stenotic (n = 15) BTV group. Univariate and multivariate binary logistic regression were performed to identify TTE Doppler parameters that detected BTV dysfunction. RESULTS: The VTI ratio (VTITV/VTILVOT) was the most accurate Doppler parameter for detecting BTV dysfunction, with a ratio of >2.8 showing 84.6% sensitivity and 90.2% specificity. VTI ratio > 3.2, mean gradient (MGTV) > 6.2 mmHg and pressure half-time > 218 ms detected significant BTV stenosis, with sensitivities of 100%, 93.3% and 93.3% and specificities of 82.4%, 75.3% and 87.1%, respectively. After multivariate analysis, the VTI ratio > 2.8 (OR = 9.00, 95% CI = 2.13-41.61, p = .003) and MGTV > 5.1 mmHg (OR = 6.50, 95% CI = 1.69-27.78, p = .008) were the independent associations of BTV dysfunction. With these cutoff values, 75.0%-92.2% of normal and 62.5%-96.0% of dysfunctional BTV were identified. CONCLUSIONS: Doppler parameters from TTE can accurately identify BTV dysfunction, particularly with VTI ratio > 2.8 and MGTV > 5.1 mmHg, to assess the need for additional testing with TEE.


Subject(s)
Bioprosthesis , Echocardiography, Doppler , Heart Valve Prosthesis , Sensitivity and Specificity , Tricuspid Valve , Humans , Female , Male , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Middle Aged , Echocardiography, Doppler/methods , Retrospective Studies , Reproducibility of Results , Aged , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/diagnostic imaging
3.
Echocardiography ; 41(5): e15821, 2024 May.
Article in English | MEDLINE | ID: mdl-38706373

ABSTRACT

INTRODUCTION: Doppler-derived pulmonary pulse transit time (pPTT) is an auspicious hemodynamic marker in chronic pulmonary diseases. The aim is to compare four distinct pPTT measurements and its relation to right cardiac and pulmonary function. METHODS: Prospectively, 25 chronic obstructive pulmonary disease (COPD) patients (four patients excluded) and 32 healthy subjects underwent repeated distinct pPTT measurements, standard echocardiography, and pulmonary function testing on the same day. pPTT was defined as the interval from the R or Q-wave in the electrocardiogram to the corresponding pulse wave Doppler peak late systolic (S) 2 or diastolic (D) pulmonary vein flow velocity (pPTT R-S, Q-S, R-D, Q-D). Reproducibility was assessed using Bland-Altman analysis, coefficient of variation (COV), intraclass correlation coefficient (ICC), and power calculations. Associations with right ventricular RV tissue and pulse wave Doppler velocities (RV E', RV S', RV A', RV E, RV A, RV E/E', RV E/A), TAPSE, right ventricular fractional area change, left ventricular systolic and diastolic function (LV ejection fraction, E, A, E/A, E/E', septal E', lateral E'), LA diameters, as well as forced expiratory volume in 1 s, forced vital capacity (FVC) predicted (%), and in liters were analyzed. RESULTS: There was no significant difference and no bias between pPTT measures (p range: .1-.9). COV was in COPD 1.2%-2.3%, in healthy subjects 1.0%-3.1%. ICC ranged from .92 (COPD) to .96 (healthy subjects). In COPD significant correlations were found for pPTT R-S, Q-S and R-D with RV E`, (all > ρ: .49, < p = .0364), pPTT R-S, Q-S with RV E/E` (both > ρ: .49, < p = .0291), pPTT Q-S with RV S´ (ρ: .58, p = .0134), RV A (ρ: .59, p = .0339) and heart rate > ρ: -.39, < p = .0297). pPTT R-S, R-D showed significant correlations with FVC predicted (%) (ρ: .48 p = .0224) and FVC (l) (ρ:.47 p = .0347). CONCLUSIONS: All pPTT measures exhibited high reproducibility. In COPD patients pPTT measures correlate with diastolic right ventricular function. Defining Q as starting point seems clinically advantageous considering electromechanical desynchrony in patients with conduction disorders.


Subject(s)
Echocardiography, Doppler , Pulmonary Disease, Chronic Obstructive , Pulse Wave Analysis , Humans , Pulmonary Disease, Chronic Obstructive/physiopathology , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Male , Female , Reproducibility of Results , Pulse Wave Analysis/methods , Prospective Studies , Echocardiography, Doppler/methods , Aged , Middle Aged , Respiratory Function Tests/methods , Blood Flow Velocity/physiology
4.
Open Heart ; 11(1)2024 May 23.
Article in English | MEDLINE | ID: mdl-38782543

ABSTRACT

BACKGROUND: The relationship between speckle tracking assessed global longitudinal strain (GLS) and Doppler-based echocardiography with basic physiological markers of cardiac function derived from pressure-volume loops is poorly elucidated. OBJECTIVE: We aimed to describe the association between LS and Doppler-based echocardiography and direct measurements of central haemodynamic parameters from conductance catheter-based pressure-volume loops in an animal model with increasing left ventricular (LV) dysfunction. METHODS: 12 Danish landrace female pigs (75-80 kg) were used. All instrumentations were performed percutaneously, including the conductance catheter in the LV. Progressive LV dysfunction was induced by embolisation through the left main coronary artery with microspheres every 3 min until a >50% reduction in cardiac output (CO) or mixed venous saturation (SvO2), compared with baseline, or SvO2 <30%. Echocardiography was performed at baseline and 90 s after each injection. RESULTS: With progressive LV dysfunction, mean CO decreased from 5.6±0.9 L/min to 2.1±0.9 L/min, and mean SvO2 deteriorated from 61.1±7.9% to 35.3±6.1%. Mean LS and LV outflow tract velocity time integral (LVOT VTI) declined from -13.8±3.0% to -6.1±2.0% and 16.9±2.6 cm to 7.8±1.8 cm, respectively. LS and LVOT VTI showed the strongest correlation to stroke work in unadjusted linear regression (r2=0.53 and r2=0.49, respectively). LS correlated significantly with stroke volume, end-systolic elastance, systolic blood pressure, ventriculo-arterial coupling and arterial elastance. CONCLUSION: In an animal model of acute progressive LV dysfunction, echocardiographic and conductance catheter-based measurements changed significantly. LS and LVOT VTI displayed the earliest and the largest alterations with increased myocardial damage and both correlated strongest with stroke work.


Subject(s)
Disease Models, Animal , Shock, Cardiogenic , Ventricular Dysfunction, Left , Ventricular Function, Left , Animals , Female , Ventricular Function, Left/physiology , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/diagnostic imaging , Shock, Cardiogenic/physiopathology , Shock, Cardiogenic/etiology , Echocardiography, Doppler/methods , Swine , Predictive Value of Tests
5.
PLoS One ; 19(5): e0302793, 2024.
Article in English | MEDLINE | ID: mdl-38739601

ABSTRACT

BACKGROUND: In cardiology, cardiac output (CO) is an important parameter for assessing cardiac function. While invasive thermodilution procedures are the gold standard for CO assessment, transthoracic Doppler echocardiography (TTE) has become the established method for routine CO assessment in daily clinical practice. However, a demand persists for non-invasive approaches, including oscillometric pulse wave analysis (PWA), to enhance the accuracy of CO estimation, reduce complications associated with invasive procedures, and facilitate its application in non-intensive care settings. Here, we aimed to compare the TTE and oscillometric PWA algorithm Antares for a non-invasive estimation of CO. METHODS: Non-invasive CO data obtained by two-dimensional TTE were compared with those from an oscillometric blood pressure device (custo med GmbH, Ottobrunn, Germany) using the integrated algorithm Antares (Redwave Medical GmbH, Jena, Germany). In total, 59 patients undergoing elective cardiac catheterization for clinical reasons (71±10 years old, 76% males) were included. Agreement between both CO measures were assessed by Bland-Altman analysis, Student's t-test, and Pearson correlations. RESULTS: The mean difference in CO was 0.04 ± 1.03 l/min (95% confidence interval for the mean difference: -0.23 to 0.30 l/min) for the overall group, with lower and upper limits of agreement at -1.98 and 2.05 l/min, respectively. There was no statistically significant difference in means between both CO measures (P = 0.785). Statistically significant correlations between TTE and Antares CO were observed in the entire cohort (r = 0.705, P<0.001) as well as in female (r = 0.802, P<0.001) and male patients (r = 0.669, P<0.001). CONCLUSIONS: The oscillometric PWA algorithm Antares and established TTE for a non-invasive estimation of CO are highly correlated in male and female patients, with no statistically significant difference between both approaches. Future validation studies of the Antares CO are necessary before a clinical application can be considered.


Subject(s)
Algorithms , Cardiac Output , Echocardiography, Doppler , Pulse Wave Analysis , Humans , Male , Female , Cardiac Output/physiology , Aged , Pulse Wave Analysis/methods , Echocardiography, Doppler/methods , Middle Aged , Aged, 80 and over , Oscillometry/methods
6.
Arq Bras Cardiol ; 121(3): e20230131, 2024.
Article in Portuguese, English | MEDLINE | ID: mdl-38695464

ABSTRACT

BACKGROUND: Cardiovascular complications are the leading cause of mortality in pediatric patients with chronic kidney disease (CKD). Echocardiographic assessment of diastolic function in CKD has been limited to spectral and tissue Doppler imaging, known to be less reliable techniques in pediatrics. Two-dimensional Speckle tracking echocardiography (2DST) derived left atrial (LA) strain has recently been confirmed as a robust measure of diastolic function. OBJECTIVES: To investigate LA strain role in diastolic assessment of children at different stages of CKD. METHODS: From February 2019 to July 2022, 55 CKD patients without cardiovascular symptoms and 55 controls were evaluated by standard and 2DST echocardiograms. The level of significance was set at 5% (p<0.05). RESULTS: Patients and controls had similar age [9.78 (0.89 - 17.54) vs. 10.72 (1.03 -18,44) years; p = 0.41] and gender (36M:19F vs. 34M:21F; p=0.84). There were 25 non-dialysis patients and 30 dialysis patients. Left ventricular ejection fraction was ≥ 55% in all of them. Comparing CKD and controls, LA reservoir strain was lower (48.22±10.62% vs. 58.52±10.70%) and LA stiffness index was higher [0.14 (0.08-0.48)%-1 vs. 0.11 (0.06-0.23) %-1]; p<0.0001. LV hypertrophy was associated with lower LA reservoir strain (42.05±8.74% vs. 52.99±9.52%), higher LA stiffness [0.23(0.11 - 0.48)%-1 vs. 0.13 (0.08-0.23) %-1 and filling indexes (2.39±0.63 cm/s x %-1 vs. 1.74±0.47 cm/s x %-1; p<0.0001. Uncontrolled hypertension was associated with lower LA reservoir strain (41.9±10.6% vs. 50.6±9.7; p=0.005). CONCLUSIONS: LA strain proved to be a feasible tool in the assessment of pediatric CKD patients and was associated with known cardiovascular risk factors.


FUNDAMENTO: As complicações cardiovasculares são a principal causa de morte em pacientes pediátricos com doença renal crônica (DRC). A avaliação ecocardiográfica da função diastólica na DRC tem se limitado à avaliação espectral por Doppler espectral e por Doppler tecidual, técnicas sabidamente menos confiáveis na pediatria. O strain do átrio esquerdo (AE) pela técnica do speckle tracking bidimensional (2DST) foi recentemente confirmada como uma medida robusta da função diastólica. OBJETIVOS: Investigar o papel do strain do AE na avaliação da função diastólica de crianças em diferentes estágios da DRC. MÉTODOS: De fevereiro de 2019 a julho de 2022, 55 pacientes com DRC sem sintomas cardiovasculares e 55 controles foram avaliados por ecocardiografia convencional e por ecocardiografia com 2DST. O nível de significância adotado foi de 5% (p < 0,05). RESULTADOS: Pacientes e controles tinham idade similares [9,78 (0,89 ­ 17,54) vs. 10,72 (1,03 ­18,44) anos; p = 0,41] e sexo (36M:19F vs. 34M:21F; p = 0,84) similares. Havia 25 pacientes não dialíticos e 30 pacientes dialíticos. A fração de ejeção do ventrículo esquerdo foi ≥ 55% em todos. Em comparação aos controles, os pacientes com DRC apresentaram strain de reservatório mais baixo (48,22±10,62% vs. 58,52±10,70%) e índice de rigidez do AE mais alto [0,14 (0,08­0,48)%-1 vs. 0,11 (0,06­0,23) %-1]; p<0,0001. A hipertrofia ventricular esquerda associou-se com um strain de reservatório mais baixo (42,05±8,74% vs. 52,99±9,52%), e valores mais altos de índice de rigidez [0,23 (0,11 ­ 0,48)%-1 vs. 0,13 (0,08­0,23) %-1 e de índice de enchimento do AE (2,39±0,63 cm/s x %-1 vs. 1,74±0,47 cm/s x %-1; p<0,0001). Hipertensão não controlada associou-se com strain de reservatório do AE mais baixo (41,9±10,6% vs. 50,6±9,7; p=0,005). CONCLUSÃO: O strain do AE mostrou-se uma ferramenta útil na avaliação de pacientes pediátricos com DRC e associado com fatores de risco cardiovasculares conhecidos.


Subject(s)
Diastole , Echocardiography , Renal Insufficiency, Chronic , Humans , Female , Male , Child , Renal Insufficiency, Chronic/physiopathology , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/diagnostic imaging , Adolescent , Diastole/physiology , Child, Preschool , Case-Control Studies , Echocardiography/methods , Infant , Stroke Volume/physiology , Echocardiography, Doppler/methods , Ventricular Function, Left/physiology , Heart Atria/physiopathology , Heart Atria/diagnostic imaging , Reference Values
7.
Sci Rep ; 14(1): 12115, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38802474

ABSTRACT

Previous investigations have highlighted notable variations in cardiovascular risk indicators associated with various professional categories. However, only a few studies have examined structural and functional cardiac parameters using echocardiography within distinct occupational groups. Hence, this study endeavored to assess cardiac structural and functional parameters in three additional occupations: firefighters (FFs), police officers (POs), and office workers (OWs). This prospective study encompassed 197 male participants (97 FFs, 54 POs, and 46 OWs) from Germany. All participants underwent 2D and Doppler echocardiography in resting conditions; standard parasternal and apical axis views were employed to evaluate structural (diastolic and systolic) and functional (systolic and diastolic function, and strain) cardiac parameters. All three occupational groups exhibited a tendency towards septal hypertrophy. Notably, OWs exhibited the largest diastolic interventricular septum diameter (IVSd), at 1.33 ± 0.25 cm. IVSd significantly varied between POs and OWs (p = 0.000) and between POs and FFs (p = 0.025). Additionally, during diastole a substantially larger left ventricular posterior wall diameter (LVPWd) was observed in OWs compared to FFs (p = 0.001) and POs (p = 0.013). The left ventricular diastolic cavity diameter (LVIDd) and the left ventricular systolic cavity diameter (LVIDs) were significantly higher in POs than they were in FFs (LVIDd: p = 0.001; LVIDs: p = 0.009), and the LVIDd was notably higher in FFs (p = 0.015) and POs compared to OWs (p = 0.000). FFs exhibited significantly better diastolic function, indicated by higher diastolic peak velocity ratios (MV E/A ratio) and E/E' ratios, compared to POs (E/A ratio: p = 0.025; E/E' ratio: p = 0.014). No significant difference in diastolic performance was found between OWs and FFs. Significantly higher E'(lateral) values were noted in POs compared to FFs (p = 0.003) and OWs (p = 0.004). Ejection fraction did not significantly differ among FFs, POs, and OWs (p > 0.6). The left ventricular mass (LV Mass) was notably higher in POs than it was in FFs (p = 0.039) and OWs (p = 0.033). Strain parameter differences were notably improved in two- (p = 0.006) and four-chamber (p = 0.018) views for FFs compared to POs. Concentric remodeling was the predominant change observed in all three occupational groups. Significant differences in the presence of various forms of hypertrophy were observed in FFs, POs, and OWs (exact Fisher test p-values: FFs vs. OWs = 0.021, POs vs. OWs = 0.002). OWs demonstrated notably higher rates of concentric remodeling than FFs did (71.77% vs. 47.9%). This study underscores disparities in both functional and structural parameters in diverse occupational groups. Larger prospective studies are warranted to investigate and delineate differences in structural and functional cardiac parameters across occupational groups, and to discern their associated effects and risks on the cardiovascular health of these distinct professional cohorts.


Subject(s)
Echocardiography , Humans , Male , Cross-Sectional Studies , Adult , Middle Aged , Prospective Studies , Echocardiography, Doppler , Firefighters , Heart Ventricles/diagnostic imaging , Germany , Occupations , Diastole/physiology , Police , Heart/physiology , Workplace , Ventricular Function, Left/physiology , Working Conditions
8.
Ultrasonics ; 140: 107307, 2024 May.
Article in English | MEDLINE | ID: mdl-38579486

ABSTRACT

BACKGROUND AND OBJECTIVE: With the development of advanced clutter-filtering techniques by singular value decomposition (SVD) and leveraging favorable acquisition settings such as open-chest imaging by a linear high-frequency probe and plane waves, several studies have shown the feasibility of cardiac flow measurements during the entire cardiac cycle, ranging from coronary flow to myocardial perfusion. When applying these techniques in a routine clinical setting, using transthoracic ultrasound imaging, new challenges emerge. Firstly, a smaller aperture is needed that can fit between ribs. Consequently, diverging waves are employed instead of plane waves to achieve an adequate field of view. Secondly, to ensure imaging at a larger depth, the maximum pulse repetition frequency has to be reduced. Lastly, in comparison to the open-chest scenario, tissue motion induced by the heartbeat is significantly stronger. The latter complicates substantially the distinction between clutter and blood signals. METHODS: This study investigates a strategy to overcome these challenges by diverging wave imaging with an optimal number of tilt angles, in combination with dedicated clutter-filtering techniques. In particular, a novel, adaptive, higher-order SVD (HOSVD) clutter filter, which utilizes spatial, temporal, and angular information of the received ultrasound signals, is proposed to enhance clutter and blood separation. RESULTS: When non-negligible tissue motion is present, using fewer tilt angles not only reduces the decorrelation between the received waveforms but also allows for collecting more temporal samples at a given ensemble duration, contributing to improved Doppler performance. The addition of a third angular dimension enables the application of HOSVD, providing greater flexibility in selecting blood separation thresholds from a 3-D tensor. This differs from the conventional threshold selection method in a 2-D spatiotemporal space using SVD. Exhaustive threshold search has shown a significant improvement in Contrast and Contrast-to-Noise ratio for Power Doppler images filtered with HOSVD compared to the SVD-based clutter filter. CONCLUSION: With the improved settings, the obtained Power Doppler images show the feasibility of measuring coronary flow under the influence of non-negligible tissue motion in both in vitro and ex vivo.


Subject(s)
Coronary Circulation , Coronary Circulation/physiology , Phantoms, Imaging , Animals , Humans , Algorithms , Echocardiography, Doppler/methods , Image Processing, Computer-Assisted/methods , Blood Flow Velocity/physiology , Swine
9.
Med. intensiva (Madr., Ed. impr.) ; 48(4): 220-230, abr. 2024. ilus
Article in English | IBECS | ID: ibc-231957

ABSTRACT

Echocardiography enables the intensivist to assess the patient with circulatory failure. It allows the clinician to identify rapidly the type and the cause of shock in order to develop an effective management strategy. Important characteristics in the setting of shock are that it is non-invasive and can be rapidly applied. Early and repeated echocardiography is a valuable tool for the management of shock in the intensive care unit. Competency in basic critical care echocardiography is now regarded as a mandatory part of critical care training with clear guidelines available. The majority of pathologies found in shocked patients are readily identified using basic level 2D and M-mode echocardiography. The four core types of shock (cardiogenic, hypovolemic, obstructive, and septic) can readily be identified by echocardiography. Echocardiography can differentiate the different pathologies that may be the cause of each type of shock. More importantly, as a result of more complex and elderly patients, the shock may be multifactorial, such as a combination of cardiogenic and septic shock, which emphasises on the added value of transthoracic echocardiography (TTE) in such population of patients. In this review we aimed to provide to clinicians a bedside strategy of the use of TTE parameters to manage patients with shock. In the first part of this overview, we detailed the different TTE parameters and how to use them to identify the type of shock. And in the second part, we focused on the use of these parameters to evaluate the effect of treatments, in different types of shock. (AU)


La ecocardiografía permite al intensivista valorar al paciente con fallo circulatorio agudo. Esta técnica ayuda a identificar, rápidamente y de una manera no invasiva, el tipo y la causa del shock para instaurar una estrategia terapéutica. La realización de exámenes ecocardiográficos precoces y repetidos es una valiosa herramienta para el manejo del shock en la unidad de cuidados intensivos. La mayoría de patologías responsables del shock pueden ser identificadas con un nivel básico de ecocardiografía en 2D y modo M. En la actualidad, las competencias en ecocardiografía básica se consideran mandatorias en la formación de los profesionales de Medicina Intensiva. Los cuatro tipos básicos de shock (cardiogénico, hipovolémico, obstructivo y séptico) pueden ser adecuadamente identificados con la ecocardiografía. Además, la ecografía puede diferenciar las diferentes patologías que pueden ser la causa de cada uno de los tipos de shock. Es importante señalar que, dada la complejidad y la edad avanzada de muchos pacientes críticos, el shock puede ser multifactorial (p.ej.: combinación de shock séptico y cardiogénico), lo que enfatiza el valor añadido de la ecocardiografía transtorácica (ETT) en esta población de pacientes. En esta revisión, queremos proporcionar a los clínicos una estrategia, a pie de cama, del uso de los parámetros obtenidos con la ETT para manejo de los pacientes en shock. En la primera parte de este artículo, se detallan los diferentes parámetros ecocardiográficos y cómo pueden utilizarse para identificar los tipos de shock. En la segunda parte, se expone el uso de estos parámetros para evaluar el efecto de los tratamientos en los diferentes tipos de shock. (AU)


Subject(s)
Humans , Echocardiography/history , Echocardiography/instrumentation , Echocardiography/methods , Echocardiography/trends , Echocardiography, Doppler/instrumentation , Echocardiography, Doppler/methods , Echocardiography, Doppler/trends
11.
BMC Pregnancy Childbirth ; 24(1): 264, 2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38605306

ABSTRACT

BACKGROUND: Maternal diabetes adversely affects fetal cardiovascular system development. Previous studies have reported that the fetuses of mothers with diabetes exhibit both structural and functional changes; nevertheless, prior studies have not examined the association between glucose control and fetal cardiac morphology and performance. Thus, the objective was to determine the association between fetal cardiac morphology and function and maternal glucose control in type 1 diabetes and to compare the differences in measured cardiac parameters between the fetuses of mothers with diabetes and healthy controls. METHODS: In this prospective, longitudinal case-control study - including 62 pregnant women with type 1 diabetes mellitus and 30 healthy pregnant women - fetal cardiac assessment using B-mode, M-mode, and spectral pulsed-wave Doppler was performed in the second and third trimesters. In women with T1DM, glycated hemoglobin and data obtained from glucose sensors - including the percentage of time in, below, and above the range (TIR, TBR, and TAR, respectively), and coefficient of variation (CV) - were analyzed across three time periods: the last menstrual period to 13 (V1), 14-22 (V2), and 23-32 weeks (V3) of gestation. Fetal cardiac indices were compared between groups, and the correlation between glucose control and fetal cardiac indices was assessed. RESULTS: At 28-32 weeks, the fetuses of women with T1DM exhibited increased left ventricular end-diastolic length, relative interventricular septum thickness, right ventricular cardiac output, and pulmonary valve peak systolic velocity compared with healthy controls. At 18-22 weeks, pulmonary and aortic valve diameters, left and right ventricular stroke volumes, and left cardiac output inversely correlated with the CV and glycated hemoglobin levels at V1 and V2. Furthermore, at 28-32 weeks, pulmonary and aortic valve diameters, left ventricular stroke volume, cardiac output, and right/left atrioventricular valve ratio inversely correlated with the TBR at V1, V2, and V3. Moreover, diastolic functional parameters correlated with the TAR and glycated hemoglobin levels, particularly after the first trimester. CONCLUSION: In women with T1DM, maternal hyperglycemia during pregnancy correlates with fetal diastolic function, whereas glucose variability and hypoglycemia inversely correlate with fetal left ventricular systolic function in the second and third trimesters.


Subject(s)
Diabetes Mellitus, Type 1 , Diabetes, Gestational , Nijmegen Breakage Syndrome , Pregnancy , Humans , Female , Diabetes Mellitus, Type 1/complications , Echocardiography, Doppler , Blood Glucose , Glycated Hemoglobin , Prospective Studies , Case-Control Studies , Longitudinal Studies , Fetal Heart/diagnostic imaging , Hemodynamics , Ultrasonography, Prenatal
12.
PLoS One ; 19(3): e0292694, 2024.
Article in English | MEDLINE | ID: mdl-38466681

ABSTRACT

BACKGROUND: Transthoracic Echocardiography is the first-line, non-invasive, and accessible imaging modality to evaluate heart disease anatomy, physiology, and hemodynamics. We aim to describe the trans-thoracic echocardiography pattern of pediatric heart diseases and reasons for referral in children referred to Bahir Dar University Tibebe-Ghion Hospital and Adinas General Hospital. METHOD: A descriptive cross-sectional study of the archived Transthoracic, Two Dimensional, and Doppler Echocardiography assessments of children from birth to fifteen years of age performed between June 2019 to May 2023 was done. Data were collected retrospectively from February 01, 2023 -May 31, 2023. Categorical variables like gender, referral reasons for echocardiography, and patterns of pediatric heart lesions were analyzed in the form of proportions and presented in tables and figures. Discrete variables including age were summarized as means (SD) and medians(IQR). RESULTS: Out of 3,647 Children enrolled; 1,917 (52.6%) were males and 1,730 (47.4%) were females. The median (IQR) age of children enrolled was 24 months (5 to 96). Cardiac murmur (33%) was the most common reason for echocardiography followed by, Respiratory Distress (18%), Syndromic Child (15%), easy fatigability/ Diaphoresis (14.3%), congestive heart failure (14%), and rheumatic fever (13.2%). Congenital heart defect (CHD) accounts for 70% of all heart diseases, followed by rheumatic heart disease (21%). Isolated ventricular septal defect(VSD) was the most common CHD (21%) followed by isolated Patent ductus arteriosus (15%), isolated atrial septal defect (10%), Isolated atrioventricular septal defect (6%) and isolated pulmonary stenosis (5%). Cyanotic CHD accounts for 11.5% of all heart diseases. Tetralogy of Fallot (30%), d-TGA (20%), and double outlet right ventricle (19%) were the most common cyanotic CHDs. CONCLUSIONS: In our study, congenital heart lesions are the most common diagnosis and cardiac murmurs are the most common presenting reasons for echocardiography evaluation.


Subject(s)
Heart Defects, Congenital , Heart Septal Defects, Ventricular , Male , Female , Child , Humans , Child, Preschool , Retrospective Studies , Cross-Sectional Studies , Developing Countries , Ethiopia/epidemiology , Hospitals, General , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/epidemiology , Echocardiography, Doppler , Echocardiography/methods , Hospitals, University , Heart Murmurs
13.
Eur J Gastroenterol Hepatol ; 36(6): 775-783, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38526935

ABSTRACT

Left ventricular diastolic dysfunction (LVDD) is the predominant cardiac abnormality in cirrhosis. We investigated the association of LVDD with systemic inflammation and its impact on renal function, occurrence of hepatorenal syndrome (HRS) and survival in patients with cirrhosis and ascites. We prospectively enrolled 215 patients with cirrhosis and ascites. We evaluated the diagnosis and grading of LVDD by Doppler echocardiography, inflammatory markers, systemic hemodynamics, vasoactive factors, radioisotope-assessed renal function and blood flow, HRS development and liver-related mortality. LVDD was diagnosed in 142 (66%) patients [grade 2/3: n  = 61 (43%)]. Serum lipopolysaccharide-binding protein (LBP), plasma renin activity (PRA) and glomerular filtration rate (GFR) were independently associated with the presence of grade 2/3 LVDD and the severity of diastolic dysfunction. Serum tumor necrosis factor-α, cardiac output and plasma noradrenaline were also independently associated with the presence of grade 2/3 LVDD. The diastolic function marker E / e ' was strongly correlated with serum LBP ( r  = 0.731; P  < 0.001), PRA ( r  = 0.714; P  < 0.001) and GFR ( r  = -0.609; P  < 0.001) among patients with LVDD. The 5-year risk of HRS development and death was significantly higher in patients with grade 2/3 LVDD compared to those with grade 1 (35.5 vs. 14.4%; P  = 0.01 and 53.3 vs. 28.2%; P  = 0.03, respectively). The occurrence and severity of LVDD in patients with cirrhosis and ascites is closely related to inflammatory activity. Advanced LVDD is associated with baseline circulatory and renal dysfunction, favoring HRS development, and increased mortality.


Subject(s)
Acute-Phase Proteins , Ascites , Biomarkers , Glomerular Filtration Rate , Hepatorenal Syndrome , Liver Cirrhosis , Membrane Glycoproteins , Ventricular Dysfunction, Left , Humans , Female , Male , Liver Cirrhosis/complications , Liver Cirrhosis/mortality , Liver Cirrhosis/physiopathology , Middle Aged , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left/mortality , Hepatorenal Syndrome/mortality , Hepatorenal Syndrome/physiopathology , Hepatorenal Syndrome/etiology , Ascites/etiology , Ascites/physiopathology , Ascites/mortality , Prospective Studies , Aged , Biomarkers/blood , Severity of Illness Index , Echocardiography, Doppler , Risk Factors , Adult , Prognosis , Inflammation/blood , Kidney/physiopathology , Inflammation Mediators/blood , Carrier Proteins/blood , Diastole , Renin/blood
16.
J Am Coll Cardiol ; 83(12): 1109-1119, 2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38508842

ABSTRACT

BACKGROUND: Conflicting prognostic results have been reported in patients with discordant high-gradient aortic stenosis ([DHG-AS] the combination of a mean pressure gradient ≥40 mm Hg and an aortic valve area [AVA] >1 cm2). Moreover, existing studies only included selected patients without concomitant aortic regurgitation. OBJECTIVES: The authors assessed the prevalence and survival of patients presenting with DHG-AS in an unselected group of consecutive patients presenting to the echocardiography laboratory of a tertiary referral center. METHODS: A total of 3,547 adult patients with AVA ≤1.5 cm2 and peak aortic jet velocity ≥2.5 m/s or mean gradient ≥25 mm Hg who presented between 2005 and 2015 were included. Baseline clinical and echocardiographic data, and, when available, aortic valve calcium (AVC) score were collected in an institutional database, with subsequent retrospective analysis. The primary endpoint was all-cause mortality during follow-up. RESULTS: DHG-AS was observed in 163 patients (11.6% of patients with a high gradient). After adjustment for potential confounders, overall mortality rate of patients with DHG-AS was similar to that of patients with concordant severe aortic stenosis (HR: 0.98 [95% CI: 0.66-1.44]; P = 0.91), and patients with discordant low-gradient aortic stenosis (HR: 0.85 [95% CI: 0.58-1.26]; P = 0.42), and higher than concordant moderate aortic stenosis (HR: 0.54 [95% CI: 0.36-0.81]; P = 0.003). After adjustment for aortic velocities, aortic regurgitation had no significant impact on survival. AVC was higher than in patients with concordant moderate aortic stenosis and discordant low-gradient aortic stenosis, and not significantly different from that of concordant severe aortic stenosis. CONCLUSIONS: DHG-AS is not uncommon. Whereas AVA >1.0 cm2 is often seen as moderate aortic stenosis, a high-pressure gradient conveys a poor prognosis, whatever the AVA and the severity of concomitant aortic regurgitation.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Humans , Retrospective Studies , Prevalence , Echocardiography, Doppler , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/epidemiology , Aortic Valve/diagnostic imaging , Severity of Illness Index , Stroke Volume
17.
Comput Biol Med ; 171: 108192, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38417384

ABSTRACT

Doppler echocardiography is a widely utilised non-invasive imaging modality for assessing the functionality of heart valves, including the mitral valve. Manual assessments of Doppler traces by clinicians introduce variability, prompting the need for automated solutions. This study introduces an innovative deep learning model for automated detection of peak velocity measurements from mitral inflow Doppler images, independent from Electrocardiogram information. A dataset of Doppler images annotated by multiple expert cardiologists was established, serving as a robust benchmark. The model leverages heatmap regression networks, achieving 96% detection accuracy. The model discrepancy with the expert consensus falls comfortably within the range of inter- and intra-observer variability in measuring Doppler peak velocities. The dataset and models are open-source, fostering further research and clinical application.


Subject(s)
Deep Learning , Blood Flow Velocity , Echocardiography, Doppler/methods , Mitral Valve/diagnostic imaging , Ultrasonography, Doppler
18.
Echocardiography ; 41(2): e15756, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38400581

ABSTRACT

BACKGROUND: Elevated filling pressure is a hallmark of heart failure (HF) and portends poor prognosis. Accurate diagnosis is challenging, given that patients with normal filling pressure at rest develop disproportionate elevation with sudden preload increase. We aimed to test the accuracy of the ratio between mitral inflow velocity (E) and left ventricular stroke volume (SV) to identify patients with elevated filling pressure with passive leg lifting (PLL) and compare this with other echocardiographic surrogates of filling pressure. METHODS: Doppler echocardiography and right heart catheterization (RHC) were simultaneously performed in 37 patients (11 males, mean age 67 ± 12 years) with exertional dyspnea. Twenty-six healthy controls (14 males, mean age 60 ± 12 years) were added as reference. SV, cardiac output (CO), tricuspid regurgitation peak gradient (TRG), mitral E-wave (E) and early myocardial velocity (e') were obtained at rest and with PLL. E/SV, E/CO and E/e' were calculated and correlated with invasive pulmonary capillary wedge pressures (PCWP) with PLL. RESULTS: During PLL, E/SV (AUC = 0.94) displayed stronger diagnostic ability to identify PCWP >15 mmHg than E/e' (AUC = 0.81), mitral E/A ratio (0.76) and resting invasive PCWP (0.84). An E/SV cutoff of >1.0 showed 88% sensitivity and 75% specificity to identify elevated PCWP. Further, 10 patients (27%) were reassigned during PLL from normal to postcapillary pulmonary hypertension (postCPH), and 6 patients (16%) switched diagnosis from precapillary PH (preCPH) to postCPH. CONCLUSION: The novel E/SV ratio identifies patients with elevated PCWP with PLL and displays stronger diagnostic performance than routinely utilized echocardiographic measures such as E/e' in addition to resting, catheterization derived PCWP.


Subject(s)
Cardiac Catheterization , Leg , Male , Humans , Middle Aged , Aged , Stroke Volume , Cross-Sectional Studies , Pulmonary Wedge Pressure , Echocardiography, Doppler , Ventricular Function, Left
20.
J Am Soc Echocardiogr ; 37(2): 119-170, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38309834

ABSTRACT

Echocardiography is a fundamental component of pediatric cardiology, and appropriate indications have been established for its use in the setting of suspected, congenital, or acquired heart disease in children. Since the publication of guidelines for pediatric transthoracic echocardiography in 2006 and 2010, advances in knowledge and technology have expanded the scope of practice beyond the use of traditional modalities such as two-dimensional, M-mode, and Doppler echocardiography to evaluate the cardiac segmental structures and their function. Adjunct modalities such as contrast, three-dimensional, and speckle-tracking echocardiography are now used routinely at many pediatric centers. Guidelines and recommendations for the use of traditional and newer adjunct modalities in children are described in detail in this document. In addition, suggested protocols related to standard operations, infection control, sedation, and quality assurance and improvement are included to provide an organizational structure for centers performing pediatric transthoracic echocardiograms.


Subject(s)
Cardiology , Heart Diseases , Child , Humans , United States , Echocardiography/methods , Echocardiography, Doppler/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...