Results 1 - 20 de 7.195
Filter
1.
Catheter Cardiovasc Interv ; 103(7): 1148-1151, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38639161

ABSTRACT

The transcatheter edge-to-edge mitral valve repair (TEER) has been recommended as a reliable treatment option for selected patients with severe degenerative and functional mitral regurgitation (MR). Although MR patients with rheumatic etiology were excluded from two significant trials (EVEREST II and COAPT) that established a role for the TEER in degenerative and functional MR. However, it has been reported that the TEER procedure could be safely and effectively performed in carefully selected rheumatic MR patients. Therefore, we share a case report of successfully treating severe rheumatic MR using a novel-designed TEER system (JensClipTM).


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Rheumatic Heart Disease , Severity of Illness Index , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/etiology , Cardiac Catheterization/instrumentation , Treatment Outcome , Rheumatic Heart Disease/diagnostic imaging , Rheumatic Heart Disease/surgery , Rheumatic Heart Disease/physiopathology , Rheumatic Heart Disease/therapy , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Female , Echocardiography, Transesophageal , Echocardiography, Doppler, Color , Prosthesis Design , Heart Valve Prosthesis , Middle Aged , Male
2.
Tex Heart Inst J ; 51(1)2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38686682

ABSTRACT

Quadricuspid aortic valve is a rare congenital cardiac anomaly with an incidence of 0.008% to 0.043%. Its clinical course varies depending on cusp anatomy, function, and associated cardiac malformations. It frequently progresses to aortic valve regurgitation that may require surgical valve replacement. Detection has shifted from incidental discovery during autopsies or cardiac surgeries in the early 20th century to various cardiac imaging methods in recent decades. In addition to contributing to the literature, this report supports the use of transesophageal echocardiography more liberally to detect aortic valve abnormalities. The case presents a 48-year-old female patient with an incidentally discovered quadricuspid aortic valve.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Echocardiography, Transesophageal , Heart Defects, Congenital , Incidental Findings , Humans , Female , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Middle Aged , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/etiology , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/surgery , Heart Defects, Congenital/diagnostic imaging , Predictive Value of Tests , Heart Valve Prosthesis Implantation , Echocardiography, Doppler, Color
3.
J Am Soc Echocardiogr ; 37(6): 591-598, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38522488

ABSTRACT

BACKGROUND: Echocardiographic grading of mitral regurgitation (MR) in mitral valve prolapse (MVP) is challenging. Three-dimensional (3D) vena contracta area (VCA) has been proposed as a valuable method. However, data defining the cutoff values of severity and validation in the subset of patients with MVP are scarce. The aim of this study was to validate the 3D VCA by 3D color-Doppler transesophageal echocardiography (TEE) in patients with MVP and to define the cutoff values of severity grading. The secondary aim was to compare 3D VCA to the effective regurgitant orifice area estimation by proximal isovelocity surface area (EROA-PISA) method. METHODS: A total of 1,138 patients with at least moderate MR who underwent TEE were included. Three-dimensional VCA was measured, and the cutoff value and area under the curve (AUC) for the prediction of severe MR were estimated by receiver operating characteristic curve using a guideline-suggested multiparametric approach as the reference standard. In a subgroup of patients, 3D regurgitant volume (RV) and 3D fraction were calculated from mitral and left ventricular outflow tract stroke volumes to further validate 3D VCA against a 3D volumetric reference standard. RESULTS: The optimal 3D VCA cutoff value for predicting severe MR was 0.45 cm2 (specificity, 0.87; sensitivity, 0.90) with an AUC of 0.95 using a multiparametric approach as reference. Three-dimensional VCA had a good linear correlation with EROA-PISA (r = 0.62, P < .05) with larger values compared to EROA-PISA (0.63 cm2 vs 0.44 cm2, P < .05). A cutoff of 0.50 cm2 (AUC of 0.84; sensitivity, 0.78; specificity, 0.78) predicts an EROA-PISA of 0.40 cm2. Three-dimensional VCA had a good linear correlation with 3D RV (r = 0.56, P < .01), with an AUC of 0.86 to predict a 3D fraction >50%. CONCLUSIONS: The present study suggests 0.45 cm2 as the best cutoff value of 3D VCA to define severe MR in patients with MVP, showing an optimal agreement with the reference standard multiparametric approach and 3D RV.


Subject(s)
Echocardiography, Three-Dimensional , Mitral Valve Insufficiency , Mitral Valve Prolapse , Severity of Illness Index , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Echocardiography, Three-Dimensional/methods , Female , Male , Mitral Valve Prolapse/complications , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/physiopathology , Middle Aged , Aged , Echocardiography, Transesophageal/methods , Echocardiography, Doppler, Color/methods , Reproducibility of Results , Mitral Valve/diagnostic imaging , ROC Curve , Retrospective Studies
4.
Curr Cardiol Rep ; 26(5): 393-404, 2024 May.
Article in English | MEDLINE | ID: mdl-38526749

ABSTRACT

PURPOSE OF REVIEW: Although rare, the development of mechanical complications following an acute myocardial infarction is associated with a high morbidity and mortality. Here, we review the clinical features, diagnostic strategy, and treatment options for each of the mechanical complications, with a focus on the role of echocardiography. RECENT FINDINGS: The growth of percutaneous structural interventions worldwide has given rise to new non-surgical options for management of mechanical complications. As such, select patients may benefit from a novel use of these established treatment methods. A thorough understanding of the two-dimensional, three-dimensional, color Doppler, and spectral Doppler findings for each mechanical complication is essential in recognizing major causes of hemodynamic decompensation after an acute myocardial infarction. Thereafter, echocardiography can aid in the selection and maintenance of mechanical circulatory support and potentially facilitate the use of a percutaneous intervention.


Subject(s)
Myocardial Infarction , Humans , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/complications , Myocardial Infarction/therapy , Percutaneous Coronary Intervention , Heart-Assist Devices/adverse effects , Echocardiography/methods , Echocardiography, Doppler, Color
5.
J Am Soc Echocardiogr ; 37(4): 408-419, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38244817

ABSTRACT

BACKGROUND: The assessment of ventricular secondary mitral regurgitation (v-SMR) severity through effective regurgitant orifice area (EROA) and regurgitant volume (RegVol) calculations using the proximal isovelocity surface area (PISA) method and the two-dimensional echocardiography volumetric method (2DEVM) is prone to underestimation. Accordingly, we sought to investigate the accuracy of the three-dimensional echocardiography volumetric method (3DEVM) and its association with outcomes in v-SMR patients. METHODS: We included 229 patients (70 ± 13 years, 74% men) with v-SMR. We compared EROA and RegVol calculated by the 3DEVM, 2DEVM, and PISA methods. The end point was a composite of heart failure hospitalization and death for any cause. RESULTS: After a mean follow-up of 20 ±11 months, 98 patients (43%) reached the end point. Regurgitant volume and EROA calculated by 3DEVM were larger than those calculated by 2DEVM and PISA. Using receiver operating characteristic curve analysis, both EROA (area under the curve, 0.75; 95% CI, 0.68-0.81; P = .008) and RegVol (AUC, 0.75; 95% CI, 0.68-0.82; P = .02) measured by 3DEVM showed the highest association with the outcome at 2 years compared to PISA and 2DEVM (P < .05 for all). Kaplan-Meier analysis demonstrated a significantly higher rate of events in patients with EROA ≥ 0.3 cm2 (cumulative survival at 2 years: 28% ± 7% vs 32% ± 10% vs 30% ± 11%) and RegVol ≥ 45 mL (cumulative survival at 2 years: 21% ± 7% vs 24% ± 13% vs 22% ± 10%) by 3DEVM compared to those by PISA and 2DEVM, respectively. In Cox multivariable analysis, 3DEVM EROA remained independently associated with the end point (hazard ratio, 1.02, 95% CI, 1.00-1.05; P = .02). The model including EROA by 3DEVM provided significant incremental value to predict the combined end point compared to those using 2DEVM (net reclassification index = 0.51, P = .003; integrated discrimination index = 0.04, P = .014) and PISA (net reclassification index = 0.80, P < .001; integrated discrimination index = 0.06, P < .001). CONCLUSIONS: Effective regurgitant orifice area and RegVol calculated by 3DEVM were independently associated with the end point, improving the risk stratification of patients with v-SMR compared to the 2DEVM and PISA methods.


Subject(s)
Echocardiography, Three-Dimensional , Heart Failure , Mitral Valve Insufficiency , Male , Humans , Female , Mitral Valve Insufficiency/diagnostic imaging , Echocardiography, Doppler, Color/methods , Echocardiography, Three-Dimensional/methods , ROC Curve , Severity of Illness Index
7.
Int J Cardiovasc Imaging ; 40(4): 757-767, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38159132

ABSTRACT

The concept of disproportionate mitral regurgitation (dispropMR) has been introduced to identify patients with functional mitral regurgitation (MR) who benefit from percutaneous treatment. We aimed to examine echocardiographic characteristics behind this entity. We retrospectively included 172 consecutive patients with reduced left ventricular ejection fraction (LVEF), and more than mild MR referred to clinically indicated echocardiography. According to the proportionality ratio (effective regurgitant orifice area (EROA)/left ventricular end-diastolic volume (LVEDV)) patients were divided into dispropMR and proportionate MR (propMR) group. Potential factors which might affect proportionality definition were analyzed. 55 patients (32%) had dispropMR. Discrepant grading of MR severity was observed when using regurgitant volume (RegVol) by proximal isovelocity surface area (PISA) method or volumetric method, with significant discordance only in dispropMR (p < 0.001). Patients with dispropMR had more frequently left ventricular foreshortened images for LVEDV calculation than patients with propMR (p = 0.003), resulting in smaller LVEDV in dispropMR group. DispropMR group had more substantial dynamic variation of regurgitant flow compared to propMR. Accordingly, EROA was consistently overestimated by standard single-point PISA method compared to serial PISA method. This was more pronounced in dispropMR (bias:10.5 ± 28.3 mm2) compared to propMR group (bias:6.4 ± 12.8 mm2). DispropMR may be found in roughly one third of clinically indicated echocardiographic studies in patients with reduced LVEF and more than mild MR. EROA overestimation due to dynamic variation of regurgitant flow and LVEDV underestimation due to LV foreshortening were more frequently found in dispropMR. Our results indicate that methodological limitations of echocardiographic MR grading could not be neglected in classifying the proportionality of MR.


Subject(s)
Mitral Valve Insufficiency , Mitral Valve , Predictive Value of Tests , Severity of Illness Index , Stroke Volume , Ventricular Function, Left , Humans , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/classification , Retrospective Studies , Female , Male , Aged , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Middle Aged , Reproducibility of Results , Echocardiography, Doppler, Color , Aged, 80 and over
8.
Angiol. (Barcelona) ; 75(6): 373-384, Nov-Dic. 2023. ilus
Article in Spanish | IBECS | ID: ibc-229799

ABSTRACT

La ecografía Doppler es una modalidad diagnóstica que depende de un operador indispensable por disponibilidad, eficacia, coste y no invasividad. Además de conocimientos anatómicos y clínicos, exige un mínimo conocimiento de sus principios físicos y tecnológicos. Este artículo intenta repasar y esquematizar cómo ajustar las principales aplicaciones del equipo en la exploración Doppler mediante los botones y los controles (knobology). Complementa a la primera parte ya editada, en la que se explicaban los ajustes en la exploración en modo B. Realizar una exploración con una postura adecuada, que evite lesiones en el explorador (ergonomía), permite también aumentar nuestro rendimiento laboral. Conocer, entrenar y ajustar las funciones del eco Doppler de forma ordenada teniendo en cuenta al paciente y el estudio indicado hará que nuestras exploraciones sean más sencillas, rápidas, seguras y precisas.(AU)


Doppler ultrasound is an operator-dependent diagnostic modality, essential due to availability, efficacy, costs and non-invasive test. In addition to anatomical and clinical knowledge, it requires a minimum knowledge of its physical and technological principles. This article attempts to review and outline how to adjust the main applications of the equipment in Doppler scanning, using the buttons and controls (knobology). It complements the first part already edited, where the adjustments in the exploration in B mode were explained.Carrying out an examination with a suitable posture, which avoids injuries to the explorer (ergonomics), also allows us to increase our work performance. Knowing, training and adjusting the echo Doppler functions in an orderly manner, considering the patient and the indicated study, will make our examinations easier, faster, safer and more precise.(AU)


Subject(s)
Humans , Male , Female , Ultrasonography, Doppler , Diagnostic Imaging/methods , Echocardiography, Doppler, Color
9.
J Ultrasound Med ; 42(12): 2707-2713, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37449663

ABSTRACT

OBJECTIVES: Patent ductus arteriosus (PDA) is a vascular defect common in preterm infants and often requires treatment to avoid associated long-term morbidities. Echocardiography is the primary tool used to diagnose and monitor PDA. We trained a deep learning model to identify PDA presence in relevant echocardiographic images. METHODS: Echocardiography video clips (n = 2527) in preterm infants were reviewed by a pediatric cardiologist and those relevant to PDA diagnosis were selected and labeled (PDA present/absent/indeterminate). We trained a convolutional neural network to classify each echocardiography frame of a clip as belonging to clips with or without PDA. A novel attention mechanism that aggregated predictions for all frames in each clip to obtain a clip-level prediction by weighting relevant frames. RESULTS: In early model iterations, we discovered training with color Doppler echocardiography clips produced the best performing classifier. For model training and validation, 1145 such clips from 66 patients (661 PDA+ clips, 484 PDA- clips) were used. Our best classifier for clip level performance obtained sensitivity of 0.80 (0.83-0.90), specificity of 0.77 (0.62-0.92) and AUC of 0.86 (0.83-0.90). Study level performance obtained sensitivity of 0.83 (0.72-0.94), specificity of 0.89 (0.79-1.0) and AUC of 0.93 (0.89-0.98). CONCLUSIONS: Our novel deep learning model demonstrated strong performance in classifying echocardiography clips with and without PDA. Further model development and external validation are warranted. Ultimately, integration of such a classifier into auto detection software could streamline PDA imaging workflow. This work is the first step toward semi-automated, bedside detection of PDA in preterm infants.


Subject(s)
Ductus Arteriosus, Patent , Infant, Premature , Infant , Child , Infant, Newborn , Humans , Ductus Arteriosus, Patent/diagnostic imaging , Echocardiography, Doppler, Color , Echocardiography , Computers
11.
Article in English | MEDLINE | ID: mdl-37363855

ABSTRACT

Color Doppler echocardiography is a widely used noninvasive imaging modality that provides real-time information about intracardiac blood flow. In an apical long-axis view of the left ventricle, color Doppler is subject to phase wrapping, or aliasing, especially during cardiac filling and ejection. When setting up quantitative methods based on color Doppler, it is necessary to correct this wrapping artifact. We developed an unfolded primal-dual network (PDNet) to unwrap (dealias) color Doppler echocardiographic images and compared its effectiveness against two state-of-the-art segmentation approaches based on nnU-Net and transformer models. We trained and evaluated the performance of each method on an in-house dataset and found that the nnU-Net-based method provided the best dealiased results, followed by the primal-dual approach and the transformer-based technique. Noteworthy, the PDNet, which had significantly fewer trainable parameters, performed competitively with respect to the other two methods, demonstrating the high potential of deep unfolding methods. Our results suggest that deep learning (DL)-based methods can effectively remove aliasing artifacts in color Doppler echocardiographic images, outperforming DeAN, a state-of-the-art semiautomatic technique. Overall, our results show that DL-based methods have the potential to effectively preprocess color Doppler images for downstream quantitative analysis.


Subject(s)
Deep Learning , Echocardiography, Doppler, Color , Echocardiography, Doppler, Color/methods , Heart Ventricles/diagnostic imaging , Thorax , Artifacts
12.
J Obstet Gynaecol Res ; 49(7): 1743-1749, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37190899

ABSTRACT

AIM: The intraventricular pressure difference (IVPD) is the pressure difference in early diastole from the base to the apex of the ventricle. It is a useful marker for evaluating diastolic function because of its role as a suction force. This study investigated the changes in total and segmental IVPDs in normal fetuses throughout gestation to obtain normative data equations. METHODS: One hundred thirty-seven healthy pregnant women at 12-40 weeks of gestation were prospectively enrolled to evaluate IVPD. The color M mode was performed, and the image was evaluated using our own code to calculate the IVPD. Segmental IVPD was divided into mid to apex and base. Pearson's correlation coefficient was used to evaluate this relationship. RESULTS: There was a significant, positive relationship between IVPD and gestational age in both ventricles (right ventricle [RV]: r = 0.800, left ventricle [LV]: r = 0.818). As for segmental IVPD, basal and mid-apical IVPD also increased with gestation in both ventricles (RV: basal, r = 0.627; mid-apical, r = 0.705; LV: basal r = 0.758; mid-apical, r = 0.756). IVPG, which was calculated as IVPD/ventricular length, also showed a weak, positive relationship with gestation in both ventricles (RV r = 0.351, p < 0.001; LV r = 0.373, p < 0.001). CONCLUSION: The total and segmental IVPDs significantly increased linearly through time.


Subject(s)
Echocardiography, Doppler, Color , Heart Ventricles , Humans , Female , Pregnancy , Ventricular Pressure , Heart Ventricles/diagnostic imaging , Echocardiography, Doppler, Color/methods , Fetus , Echocardiography
14.
ABC., imagem cardiovasc ; 36(1): e20230006, abr. 2023. ilus, tab
Article in Portuguese | LILACS | ID: biblio-1517806

ABSTRACT

A regurgitação tricúspide (RT) importante está associada à alta morbidade e mortalidade. Como o tratamento cirúrgico da RT isolada tem sido associado à alta mortalidade, as intervenções transcateter na valva tricúspide (VT) têm sido utilizadas para o seu tratamento, com risco relativamente mais baixo. Há um atraso na intervenção da RT e provavelmente está relacionado a uma compreensão limitada da anatomia da VT e do ventrículo direito, além da subestimação da gravidade da RT. Nesse cenário, faz-se necessário o conhecimento anatômico abrangente da VT, a fisiopatologia envolvida no mecanismo de regurgitação, assim como a sua graduação mais precisa. A VT tem peculiaridades anatômica, histológica e espacial que fazem a sua avalição ser mais complexa, quando comparado à valva mitral, sendo necessário o conhecimento e treinamento nas diversas técnicas ecocardiográficas que serão utilizadas frequentemente em combinação para uma avaliação precisa. Esta revisão descreverá a anatomia da VT, o papel do ecocardiograma no diagnóstico, graduação e fisiopatologia envolvida na RT, as principais opções atuais de tratamento transcateter da RT e a avaliação do resultado após intervenção transcateter por meio de múltiplas modalidades ecocardiográficas.(AU)


Severe tricuspid regurgitation (TR) is associated with high morbidity and mortality. Given that surgical treatment of TR alone has been associated with high mortality, transcatheter interventions in the tricuspid valve (TV) have been used for its treatment, with relatively lower risk. There is a delay in intervention for TR, and this is probably related to a limited understanding of the anatomy of the TV and the right ventricle, in addition to an underestimation of the severity of TR. In this scenario, it is necessary to have comprehensive anatomical knowledge of the TV, the pathophysiology involved in the mechanism of regurgitation, and more accurate grading. The TV has anatomical, histological, and spatial peculiarities that make its assessment more complex when compared to the mitral valve, requiring knowledge and training in the various echocardiographic techniques that will often be used in combination for accurate assessment. This review will describe the anatomy of the TV, the role of echocardiography in the diagnosis, grading, and pathophysiology involved in TR; the main transcatheter treatment options currently available for TR; and the assessment of outcomes after transcatheter intervention by means of multiple echocardiographic modalities.(AU)


Subject(s)
Humans , Male , Female , Tricuspid Valve/anatomy & histology , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/physiopathology , Pericardial Effusion/complications , Tricuspid Valve Insufficiency/mortality , Echocardiography/methods , Echocardiography, Transesophageal/methods , Echocardiography, Doppler, Color/methods , Echocardiography, Three-Dimensional/methods , Endocarditis/complications , Transcatheter Aortic Valve Replacement/methods
15.
J Clin Ultrasound ; 51(6): 963-971, 2023.
Article in English | MEDLINE | ID: mdl-37000708

ABSTRACT

PURPOSE: For assessing the severity of tricuspid regurgitation (TR), there is no gold standard. We developed a parameter, the right ventricular systolic force ratio-RIVIERA, using the continious wave Doppler analysis of TR and pulsed-wave analysis of the right ventricle outflow tract. We hypothesized that the RIVIERA would facilitate the ability to identify severe TR in clinical settings. MATERIALS AND METHODS: We obtained data from routine transthoracic echocardiograms. All records reporting no or mild TR (n = 732), moderate TR (n = 584), and severe TR (n = 519) TR were reanalyzed to measure vena contracta (VC) width, TR jet area, effective regurgitant orifice (EROA) derived with the proximal isovelocity surface area method, the RIVIERA, and right-sided chamber volumes. RESULTS: Significant linear trends were demonstrated for right atrial volume index, end-diastolic volume index, RVOT velocity time integral, TR jet area, TR-Vmax, TR-VTI, TR acceleration, VC width, EROA with increasing TR severity. Independent predictors of severe RT included RIVIERA <4.8, VC width ≥0.7 cm, TR jet area > 10 cm2 , and EROA ≥0.4 cm2 . CONCLUSION: The RIVIERA is a feasible, effective, and independent predictor of severe TR that enhances established techniques for estimating TR severity. For clinical decision-making and management, accurate measurement and classification of TR severity are essential. Therefore, it should be thought about include the RIVIERA in the integrative method to assessing TR severity.


Subject(s)
Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/diagnostic imaging , Heart Ventricles , Echocardiography, Doppler, Color/methods , Echocardiography , Heart Atria , Severity of Illness Index
16.
J Ultrasound Med ; 42(8): 1893-1898, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36840696

ABSTRACT

SlowflowHD is a Doppler Ultrasound modality that is typically geared toward visualization of small-size vessels and low velocity blood flow. In this commentary, we emphasize the importance of implementing the use of SlowflowHD as an adjunct to traditional Doppler modalities in the echocardiography screening in both the first and second trimester. This modality carries many characteristics that allow it to overcome the limitations of our current ultrasound modalities and facilitate mapping of the entirety of the fetal heart. The clinical implications are significant in regard to earlier acquisition of diagnostic information to guide decision-making and patient counseling.


Subject(s)
Echocardiography, Doppler, Color , Ultrasonography, Prenatal , Pregnancy , Female , Humans , Echocardiography , Fetal Heart/diagnostic imaging , Pregnancy Trimester, Second
18.
J Am Soc Echocardiogr ; 36(1): 77-86.e7, 2023 01.
Article in English | MEDLINE | ID: mdl-36208654

ABSTRACT

BACKGROUND: Spatiotemporal complexity of the color Doppler vena contracta challenging the assumption of a circular and constant orifice may lead to mitral regurgitation (MR) grading inconsistencies. Using 3D transesophageal echocardiography, we characterized spatiotemporal vena contracta complexity and its impact on MR severity grading. METHODS: In 192 patients with suspected moderate or severe MR (100 primary MR [PMR]; 92 secondary MR [SMR]), we performed three-dimensional vena contracta area (VCA) quantification using single-frame (midsystolic or VCAmid, maximum or VCAmax) and multiframe (VCAmean) methods, as well as measures of orifice shape (shape index) and systolic variation of VCA. Vena contracta complexity and intermethod discrepancies were analyzed and correlated with functional class and pulmonary vein flow (PVF) patterns and with cardiac magnetic resonance (CMR) in a subset of cases (n = 20). RESULTS: The vena contracta was noncircular (shape index > 1.5) in 90% of patients. Severe noncircularity (shape index > 3) was more prevalent in SMR than in PMR (32.4% vs 14.6%). Variations of the VCA were more prominent in SMR than in PMR. VCAmid showed a low grading agreement with VCAmax (62%) and high grading agreement with VCAmean (83.3%). Pulmonary vein flow systolic reversal was associated with MR severity by VCA in SMR but not in PMR. VCAmid and VCAmean showed a stronger association with systolic flow reversal than VCAmax (area under the curve, 0.88, 0.86, and 0.79, respectively). In the subset of patients with CMR quantification, severe MR by VCAmax was graded as nonsevere by CMR more frequently compared with VCAmid and VCAmean. CONCLUSIONS: Highly prevalent spatiotemporal vena contracta complexity features in MR challenge the assumption of a circular and constant orifice. VCAmid seems the best single-frame approximation to multiframe quantification, and VCAmax may lead to severity overestimation.


Subject(s)
Echocardiography, Three-Dimensional , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal , Echocardiography, Doppler, Color/methods , Severity of Illness Index
19.
J Cardiothorac Vasc Anesth ; 37(1): 16-22, 2023 01.
Article in English | MEDLINE | ID: mdl-36357305

ABSTRACT

OBJECTIVES: To evaluate mitral-aortic flow velocity integral ratio (MAVIR) as an echocardiographic tool to differentiate between severe and nonsevere mitral regurgitation (MR), compared with regurgitant volume (RVol) and effective regurgitant orifice area (EROA), with subgroup analysis in patients with calcific mitral valve, both by transthoracic (TTE) and transesophageal (TEE) echocardiography. Also, whether MAVIR can be used as a screening tool for severe MR. DESIGN: Prospective, cross-sectional, observational. SETTING: Cardiac operating room of a tertiary-care hospital. PARTICIPANTS: One hundred adult patients with chronic mitral regurgitation with at least mild MR by two-dimensional Doppler and with absence of mitral stenosis, aortic valve disease, and rhythm other than sinus scheduled for cardiac surgery. The subgroup (n = 24) consisted specifically of patients with a calcific mitral valve. INTERVENTIONS: Preinduction TTE and postinduction TEE in the operating room. MEASUREMENTS AND RESULTS: MAVIR, RVol, and EROA were measured in all patients both by TTE and TEE. Cohen's kappa statistics was employed to quantify concordance among RVol, EROA, and MAVIR. Diagnostic indices of MAVIR toward diagnosis of severe MR also were quantified. The results showed a strong agreement, in differentiating severe from nonsevere MR, between MAVIR and both RVol and EROA in the whole cohort (n = 100) and the subgroup (n = 24), both by TTE and TEE. Diagnostic indices were high for MAVIR compared with RVol and EROA in detecting severe MR, both by TTE and TEE. CONCLUSION: MAVIR may be used as an echocardiographic tool to differentiate between severe and nonsevere MR, even in patients with calcific valves. It also can be used to screen patients for severe MR.


Subject(s)
Echocardiography, Three-Dimensional , Mitral Valve Insufficiency , Adult , Humans , Mitral Valve Insufficiency/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Echocardiography, Doppler, Color/methods , Prospective Studies , Cross-Sectional Studies , Blood Flow Velocity , Severity of Illness Index
20.
Int J Cardiovasc Imaging ; 39(2): 307-318, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36322265

ABSTRACT

Grounded in hydrodynamic theory, proximal isovelocity surface area (PISA) is a simplistic and practical technique widely used to quantify valvular regurgitation flow. PISA provides a relatively reasonable, though slightly underestimated flow rate for circular orifices. However, for elliptical orifices frequently seen in functional mitral regurgitation, PISA underestimates the flow rate. Based on data obtained with computational fluid dynamics (CFD) and in vitro experiments using systematically varied orifice parameters, we hypothesized that flow rate underestimation for elliptical orifices by PISA is predictable and within a clinically acceptable range. We performed 45 CFD simulations with varying orifice areas 0.1, 0.3 and 0.5 cm2, orifice aspect ratios 1:1, 2:1, 3:1, 5:1, and 10:1, and peak velocities (Vmax) 400, 500 and 600 cm/s. The ratio of computed effective regurgitant orifice area to true effective area (EROAC/EROA) against the ratio of aliasing velocity to peak velocity (VA/Vmax) was analyzed for orifice shape impact. Validation was conducted with in vitro imaging in round and 3:1 elliptical orifices. Plotting EROAC/EROA against VA/Vmax revealed marginal flow underestimation with 2:1 and 3:1 elliptical axis ratios against a circular orifice (< 10% for 8% VA/Vmax), rising to ≤ 35% for 10:1 ratio. In vitro modeling confirmed CFD findings; there was a 8.3% elliptical EROA underestimation compared to the circular orifice estimate. PISA quantification for regurgitant flow through elliptical orifices produces predictable, but generally small, underestimation deemed clinically acceptable for most regurgitant orifices.


Subject(s)
Heart Valve Diseases , Mitral Valve Insufficiency , Humans , Hydrodynamics , Blood Flow Velocity , Predictive Value of Tests , Echocardiography, Doppler, Color/methods