Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.435
Filter
1.
Echocardiography ; 41(6): e15822, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38853621

ABSTRACT

BACKGROUND: Balloon sizing (BS) has been used for device size selection in percutaneous atrial septal defect (ASD) closure. Due to its limitations, alternative imaging techniques like three-dimensional transesophageal echocardiography (3D-TEE) are valuable for guiding ASD device size selection during ASD closure procedures. The purpose of this study was to compare ASD sizing using measurements obtained from 3D-TEE to those utilizing the standard balloon sizing method. METHODS: We identified 53 patients with single secundum type ASD without PFO who underwent percutaneous closure at the Tehran Heart Center between 2019 and 2022. Balloon sizing was performed in all patients with the stop-flow technique, and the choice of device size was determined based on the sizing derived from BS. 3D-TEE imaging was performed before the intervention, and the ASD shape and quality of ASD rims were assessed. RESULTS: Among the 53 patients who underwent single ASD device closure, multiple 3D TEE measurements significantly correlated with balloon sizing results. This included defect area, perimeter, and diameter obtained from 3D-TEE images multi-planar reconstruction. ASD perimeter detected by 3D TEE had the best correlation with BS results. When divided by the shape of ASD, there was no significant difference between our 3D-images data and BS in round or oval-shaped ASDs. CONCLUSION: The 3D-TEE study is reliable for assessing ASD configurational characteristics in percutaneous device closure candidates. 3D-TEE has the potential to accurately determine the appropriate device size and reduce complications, costs, and procedural duration. Further research is needed to validate these findings and establish the role of 3D-TEE measurements in guiding the best treatment decisions for ASD closure.


Subject(s)
Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Heart Septal Defects, Atrial , Septal Occluder Device , Humans , Echocardiography, Transesophageal/methods , Echocardiography, Three-Dimensional/methods , Male , Heart Septal Defects, Atrial/surgery , Heart Septal Defects, Atrial/diagnostic imaging , Female , Adult , Middle Aged , Adolescent , Prosthesis Design , Cardiac Catheterization/methods , Reproducibility of Results , Young Adult
2.
Echocardiography ; 41(6): e15861, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38853674

ABSTRACT

BACKGROUND: Transesophageal echocardiography (TEE) is primarily used to guide transcatheter structural heart interventions, such as tricuspid transcatheter edge-to-edge repair (TEER). Although TEE has a good safety profile, it is still an invasive imaging technique that may be associated with complications, especially when performed during long transcatheter procedures or on frail patients. The aim of this study was to assess TEE-related complications during tricuspid TEER. METHODS: This is a prospective study enrolling 53 patients who underwent tricuspid TEER for severe tricuspid regurgitation (TR). TEE-related complications were assessed clinically and divided into major (life-threatening, major bleeding requiring transfusions or surgery, organ perforation, and persistent dysphagia) and minor (perioral hypesthesia, < 24 h dysphagia/odynophagia, minor intraoral bleeding and hematemesis not requiring transfusion) RESULTS: The median age of the patient population was 79 years; 43.4% had severe, 39.6% massive, and 17.6% torrential TR. 62.3% of patients suffered from upper gastrointestinal disorders. Acute procedural success (APS) was achieved in 88.7% in a median device time of 36 min. A negative association was shown between APS and lead-induced etiology (r = -.284, p = .040), baseline TR grade (r = -.410, p = .002), suboptimal TEE view (r = -.349, p = .012), device time (r = -.234, p = .043), and leaflet detachment (r = -.496, p < .0001). We did not observe any clinical manifest major or minor TEE-related complications during the hospitalization. CONCLUSIONS: Our study reinforces the good safety profile and efficacy of TEE guidance during tricuspid TEER. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious complications. Furthermore, suboptimal intraprocedural TEE views are associated with lower TR reduction rates. HIGHLIGHTS: Transesophageal echocardiography is a crucial and safe technique for guiding transcatheter structural heart interventions. A mix of mid/deep esophageal and trans gastric views, as well as real-time 3D imaging is generally used to guide the procedure. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious problems. A shorter device time is associated with more rarely probe-related complications. Suboptimal intraprocedural TEE views are associated with lower TR reduction rates.


Subject(s)
Echocardiography, Transesophageal , Tricuspid Valve Insufficiency , Tricuspid Valve , Humans , Echocardiography, Transesophageal/methods , Female , Male , Prospective Studies , Tricuspid Valve Insufficiency/surgery , Aged , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Treatment Outcome , Aged, 80 and over
3.
Ann Card Anaesth ; 27(1): 51-52, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722121

ABSTRACT

ABSTRACT: The quadricuspid aortic valve is a rare congenital anomaly, usually associated with aortic regurgitation requiring surgical intervention. It may be associated with other congenital anomalies such as coronary anomalies, patent ductus arteriosus, ventricular septal defect, pulmonary stenosis, and subaortic stenosis. The diagnosis is generally established by either transthoracic or transesophageal echocardiography. Herein, we report a case of a 52-year-old woman who was diagnosed to have quadricuspid aortic valve by intraoperative transesophageal echocardiography.


Subject(s)
Aortic Valve , Echocardiography, Transesophageal , Humans , Female , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Middle Aged , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery
4.
Ann Card Anaesth ; 27(1): 68-69, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722126

ABSTRACT

ABSTRACT: The occurrence of pulmonary artery thrombus in association with rheumatic mitral stenosis is a rare complication. Pulmonary artery thrombus formation may worsen pulmonary artery pressures, and this may precipitate acute right heart failure. The possible mechanisms behind pulmonary artery thrombus formation during mitral valve replacement surgery could be acute coagulopathy following surgery, the presence of chronic pulmonary thromboembolism, or chronic atrial fibrillation. We report an unusual case of pulmonary artery thrombus in a patient with rheumatic MS which was diagnosed with transoesophageal echocardiography after MVR.


Subject(s)
Delayed Diagnosis , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation , Mitral Valve , Pulmonary Artery , Thrombosis , Humans , Heart Valve Prosthesis Implantation/adverse effects , Pulmonary Artery/diagnostic imaging , Echocardiography, Transesophageal/methods , Thrombosis/diagnostic imaging , Thrombosis/etiology , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve Stenosis/surgery , Female , Rheumatic Heart Disease/complications , Rheumatic Heart Disease/surgery , Pulmonary Embolism/etiology , Pulmonary Embolism/diagnostic imaging , Middle Aged
5.
Ann Card Anaesth ; 27(1): 70-75, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722127

ABSTRACT

ABSTRACT: A sub-mitral left ventricular aneurysm is a rare condition. It is a congenital outpouching of the left ventricular wall, invariably occurring adjacent to the posterior mitral leaflet. Sub-mitral aneurysm (SMA) has usually been reported as a consequence of myocardial ischemia (MI), rheumatic heart disease, tuberculosis, and infective endocarditis. Nevertheless, there have been few case reports of congenital SMA in India. It usually presents with symptoms of heart failure. We report a rare case of congenital SMA in a 27-year-old young Indian and its successful management through a trans-aneurysmal approach.


Subject(s)
Heart Aneurysm , Mitral Valve , Humans , Adult , Heart Aneurysm/surgery , Heart Aneurysm/diagnostic imaging , Heart Aneurysm/congenital , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Male , Heart Ventricles/surgery , Heart Ventricles/diagnostic imaging , Echocardiography, Transesophageal/methods , Anesthetics
7.
Ann Card Anaesth ; 27(1): 53-57, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722122

ABSTRACT

ABSTRACT: Aortic valve (AV) repair is the desired surgical treatment option for young patients with aortic regurgitation (AR). It is considered as a class I indication for the surgical treatment of severeAR. The success of an AV repair depends on the detailed intraoperative transesophageal echocardiographic (TEE) examination which should fulfil the information required by the surgeon. The objective of this echo round is to describe the role of intraoperative TEE in systematic evaluation of the AV, before and after repair.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Echocardiography, Transesophageal , Monitoring, Intraoperative , Child , Humans , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Echocardiography, Transesophageal/methods , Monitoring, Intraoperative/methods
8.
Medicine (Baltimore) ; 103(21): e38206, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38788025

ABSTRACT

OBJECTIVE: To evaluate left atrial volume and function in patients with paroxysmal atrial fibrillation (AF) combined with left atrial appendage thrombosis and patients with paroxysmal AF without left atrial appendage thrombosis by 3-dimensional speckle tracking imaging (3D-STI), and to explore the application value of this set of parameters in the evaluation of left atrial function in patients with paroxysmal AF. MATERIALS AND METHODS: A total of 40 patients with paroxysmal AF admitted from December 2018 to December 2020 were selected as the observation group. All patients with paroxysmal AF in the observation group underwent transesophageal echocardiography. According to the presence of left atrial appendage thrombosis, the patients were divided into the AF without thrombosis group (24 cases) and the AF with thrombosis group (16 cases). Thirty normal people were selected as control group who were chosen as having no heart-related disease. The left atrial volume parameters (Left atrial maximum volume LAVmax, Left atrial minimum volume LAVmin, Left atrial volume before atrial contraction LAVpre-A, Left atrial stroke volume LAEV), left atrial ejection fraction (LAEF) and left atrial strain parameters (Left atrial reservoir longitudinal strain LASr, Left atrial conduit longitudinal strain LAScd, Left atrial contraction longitudinal strain LASct, Left atrial reservoir circumferential strain LASr-c, Left atrial conduit circumferential strain LAScd-c, Left atrial contraction circumferential strain LASct-c) of the 3 groups were measured by 3D-STI. RESULTS: With the progression of paroxysmal AF, the left atrial volume increased, and the reservoir, conduit and contractile function were damaged. The left atrial volume continued to increase, and the reservoir, conduit and contractile function further decreased significantly in patients with AF combined with left atrial appendage thrombosis. LAEF was positively correlated with LASr and LASr_c. CONCLUSION: Real-time 3-dimensional spot tracking imaging (3D-STI) can evaluate the changes in left atrial volume and function in patients with paroxysmal AF, and has a certain reference value for clinical judgment of disease progression and prognosis.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Atrial Function, Left , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnostic imaging , Male , Female , Middle Aged , Atrial Function, Left/physiology , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Echocardiography, Three-Dimensional/methods , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Echocardiography, Transesophageal/methods , Aged , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/physiopathology
9.
Sci Rep ; 14(1): 11937, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38789491

ABSTRACT

Transesophageal echocardiography (TEE) has been the preferred imaging modality to help guide left atrial appendage closure. Newer technologies such as the Nuvision 4D Intracardiac echocardiography (ICE) catheter allow for real-time 3D imaging of cardiac anatomy. There are no direct comparison studies for procedural imaging between TEE and 4D ICE. To evaluate the performance and safety of left atrial appendage (LAA) closure procedures with the Watchman FLX and Amulet, guided by the Nuvision 4D ICE Catheter. This retrospective observational analysis was conducted on institutional LAAO National Cardiovascular Data Registry from January 2022 to March 2023. Patients had undergone LAA closure procedures with the Watchman FLX or Amulet device guided by TEE or a 4D ICE Catheter. The primary outcome evaluated was successful LAAO device placement. A total of 121 patients underwent LAAO device placement with 46 (38.0%) patients guided by 4D ICE during LAAO implantation. The 4D ICE group had a shorter procedural time compared with TEE guidance. Post procedural 45-day TEE post implant was also comparable for both groups with no patients in either group having incomplete closure of the left atrial appendage and peri-device leak > 5 mm. No device related complications (device related access, stroke, or pericardial effusion) occurred in either group at follow-up. There was no significant difference in device implant success or post procedural outcomes at 45 days in either the TEE or 4D ICE group. However, there was a noticeable improvement in procedural time with the 4D ICE catheter.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Echocardiography, Transesophageal , Humans , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Male , Female , Aged , Retrospective Studies , Echocardiography, Transesophageal/methods , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Aged, 80 and over , Echocardiography, Three-Dimensional/methods , Middle Aged , Echocardiography/methods , Treatment Outcome , Cardiac Catheters , Left Atrial Appendage Closure
10.
Echocardiography ; 41(5): e15832, 2024 May.
Article in English | MEDLINE | ID: mdl-38796741

ABSTRACT

BACKGROUND: In infants with complete atrioventricular canal (CAVC) defects, post-operative left atrioventricular valve regurgitation (LAVVR) is a known major cause of morbidity and mortality and a common indication for re-operation. However, there is scarce data to identify risk factors for poor outcomes. Our study aims to find echocardiographic characteristics that predict post-operative LAVVR at discharge and 1-year follow-up. METHODS: Retrospective cohort study of patients with initial CAVC repair at our hospital who were followed for 1 year between 2013 and 2022. Patients with major co-morbid conditions were excluded. Serial echocardiograms were reviewed. Anatomic details, quantitative and qualitative measure of LAVVR including the number of regurgitant jets, regurgitant jet length and vena contracta width, and ventricular function were collected. The time points measured include pre-operative transthoracic echocardiogram (TTE), post-operative transesophageal echocardiogram (PO-TEE), routine protocol based post-operative day 1 (POD1) TTE, discharge TTE and 1-year post-operative (1yPO) TTE. Paired t-tests, chi-square analysis, and linear regression analysis were performed comparing measured variables to LAVVR outcomes. RESULTS: Fifty-two patients were included; 92% had Trisomy 21. The majority were classified as Rastelli A (71%), others Rastelli C (29%). Only two patients had moderate or greater LAVVR pre-operatively. The mean age at repair was 125 ± 44 days. Pre-operative LAVVR was the only significant predictor of LAVVR severity at 1 year after backward stepwise regression. Of those with < moderate LAVVR on PO-TEE, 20% had worsening to ≥ moderate at discharge, but only 9% remained that way at 1 year. Of those with ≥ moderate LAVVR on PO-TEE, 40% improved to < moderate by 1 year. Two patients who worsened at 1 year, both secondary to likely cleft suture dehiscence. Only one patient required reoperation in the immediate post-operative period secondary to severe LAVVR due to suture dehiscence. Routine protocol-based POD1 echo did not have any association with altered outcomes. CONCLUSION: Pre-operative LAVVR was the only significant predictor of LAVVR severity at 1 year. A significant percentage (40%) of patient with ≥ moderate LAVVR on PO-TEE improved to < moderate by 1 year. Furthermore, routine protocol-based POD1 echo did not have any association with altered outcomes.


Subject(s)
Echocardiography , Mitral Valve Insufficiency , Postoperative Complications , Humans , Male , Female , Retrospective Studies , Infant , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Echocardiography/methods , Risk Factors , Follow-Up Studies , Echocardiography, Transesophageal/methods , Heart Septal Defects/surgery , Heart Septal Defects/complications , Heart Septal Defects/diagnostic imaging , Child, Preschool , Predictive Value of Tests
11.
J Am Coll Cardiol ; 83(22): 2179-2192, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38811095

ABSTRACT

BACKGROUND: Transcatheter correction of sinus venosus defects (SVDs) using balloon-mounted covered stents provides an attractive surgical alternative. Surgery may be complicated by superior vena caval or right upper pulmonary vein (RUPV) stenosis, sinus nodal dysfunction, and residual additional pulmonary veins. OBJECTIVES: Being a new intervention, technical modifications would simplify the procedure, improve universal applicability, and reduce or tackle complications. METHODS: Patients were included if balloon interrogation of cavoatrial junction confirmed closure of SVD and redirected RUPV to the left atrium. A single-center experience was analyzed to summarize the procedural modifications over 8 years. Transesophageal echocardiogram (TEE) on follow-up was done to identify residual shunt, RUPV flows, and stent thrombosis. RESULTS: A total of 100 patients including 9 children with a median age of 35 years (range, 4-69 years) underwent SVD closure after balloon interrogation. Among 57 patients balloon interrogated in the first 5 years, 70% underwent transcatheter closure, with 2 failures. RUPV occlusion caused the exclusions. Inclusions improved to 94% among the subsequent 65 balloon interrogations when RUPV protection was implemented, with 1 failure. Stent embolization caused the 3 failures warranting surgery. Recent modifications included limited transesophageal echocardiogram without anesthesia, avoiding venovenous circuit, interrogation with semicompliant balloons, trans-septal RUPV protection, overlapping stents to permit additional vein drainage to superior vena cava and tackle embolizations. There were no deaths. Minor complications included stent embolizations stabilized in catheterization laboratory in 2 patients, left innominate vein jailing in 2 patients, insignificant residual flows, and nonocclusive asymptomatic stent thrombosis in 4 patients. CONCLUSIONS: Procedural success was 97%. Recent modifications increased patient inclusions, decreased complications, and simplified the intervention.


Subject(s)
Cardiac Catheterization , Stents , Humans , Child , Adolescent , Child, Preschool , Male , Female , Middle Aged , Adult , Aged , Young Adult , Cardiac Catheterization/methods , Echocardiography, Transesophageal/methods , Heart Septal Defects, Atrial/surgery , Heart Septal Defects, Atrial/diagnostic imaging , Retrospective Studies , Treatment Outcome , Follow-Up Studies
17.
Tex Heart Inst J ; 51(1)2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38686682

ABSTRACT

Quadricuspid aortic valve is a rare congenital cardiac anomaly with an incidence of 0.008% to 0.043%. Its clinical course varies depending on cusp anatomy, function, and associated cardiac malformations. It frequently progresses to aortic valve regurgitation that may require surgical valve replacement. Detection has shifted from incidental discovery during autopsies or cardiac surgeries in the early 20th century to various cardiac imaging methods in recent decades. In addition to contributing to the literature, this report supports the use of transesophageal echocardiography more liberally to detect aortic valve abnormalities. The case presents a 48-year-old female patient with an incidentally discovered quadricuspid aortic valve.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Echocardiography, Transesophageal , Heart Defects, Congenital , Incidental Findings , Humans , Female , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Middle Aged , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/etiology , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/surgery , Heart Defects, Congenital/diagnostic imaging , Predictive Value of Tests , Heart Valve Prosthesis Implantation , Echocardiography, Doppler, Color
18.
Ann Noninvasive Electrocardiol ; 29(3): e13119, 2024 May.
Article in English | MEDLINE | ID: mdl-38682420

ABSTRACT

BACKGROUND: To avoid causing a thromboembolic event in patients undergoing catheter ablation for atrial fibrillation (AF), patients are treated with oral anticoagulants (OAC) prior to the procedure. Despite being on anticoagulants, some patients develop a left atrial appendage thrombus (LAAT). To exclude the presence of LAAT, transesophageal ultrasound (TEE) is performed in all patients prior to the procedure. We hypothesized continuous treatment with anticoagulants would result in a low prevalence of LAAT, in patients with low CHA2DS2-VASc score. METHOD: Medical records of consecutive patients planned to undergo AF ablation at Lund University Hospital during the years 2018-2020 were reviewed retrospectively. Examination protocols from transesophageal and transthoracic echocardiography were examined for LAAT and spontaneous echo contrast (SEC). Patients with LAAT and SEC were compared to patients without using Mann-Whitney U-test and Pearson Chi-squared analysis to test for correlation. RESULTS: Of 553 patients, three patients (0.54%) had LAAT, and 18 (3.25%) had spontaneous contrast (SEC). Patients with LAAT or SEC had a higher CHA2DS2-VASc score, more often presented in AF at TEE and less often had a normal sized left atrium. CONCLUSION: There is a low prevalence of LAAT and SEC in patients with AF scheduled for pulmonary vein isolation. Patients with SEC or LAAT tend to have paroxysmal AF less often and more often presented in AF at admission. No patients with CHA2DS2-VASc 0, paroxysmal AF, normal sized left atrium and sinus rhythm at TEE were found to have LAAT or SEC.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Echocardiography, Transesophageal , Pulmonary Veins , Thrombosis , Humans , Echocardiography, Transesophageal/methods , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Male , Female , Pulmonary Veins/surgery , Pulmonary Veins/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Catheter Ablation/methods , Retrospective Studies , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Prevalence , Middle Aged , Aged , Anticoagulants/therapeutic use , Heart Diseases/diagnostic imaging , Heart Diseases/epidemiology
19.
Ultrasound Med Biol ; 50(6): 797-804, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38485534

ABSTRACT

OBJECTIVE: Evaluation of left ventricular (LV) function in critical care patients is useful for guidance of therapy and early detection of LV dysfunction, but the tools currently available are too time-consuming. To resolve this issue, we previously proposed a method for the continuous and automatic quantification of global LV function in critical care patients based on the detection and tracking of anatomical landmarks on transesophageal heart ultrasound. In the present study, our aim was to improve the performance of mitral annulus detection in transesophageal echocardiography (TEE). METHODS: We investigated several state-of-the-art networks for both the detection and tracking of the mitral annulus in TEE. We integrated the networks into a pipeline for automatic assessment of LV function through estimation of the mitral annular plane systolic excursion (MAPSE), called autoMAPSE. TEE recordings from a total of 245 patients were collected from St. Olav's University Hospital and used to train and test the respective networks. We evaluated the agreement between autoMAPSE estimates and manual references annotated by expert echocardiographers in 30 Echolab patients and 50 critical care patients. Furthermore, we proposed a prototype of autoMAPSE for clinical integration and tested it in critical care patients in the intensive care unit. RESULTS: Compared with manual references, we achieved a mean difference of 0.8 (95% limits of agreement: -2.9 to 4.7) mm in Echolab patients, with a feasibility of 85.7%. In critical care patients, we reached a mean difference of 0.6 (95% limits of agreement: -2.3 to 3.5) mm and a feasibility of 88.1%. The clinical prototype of autoMAPSE achieved real-time performance. CONCLUSION: Automatic quantification of LV function had high feasibility in clinical settings. The agreement with manual references was comparable to inter-observer variability of clinical experts.


Subject(s)
Anatomic Landmarks , Echocardiography, Transesophageal , Ventricular Function, Left , Humans , Echocardiography, Transesophageal/methods , Ventricular Function, Left/physiology , Anatomic Landmarks/diagnostic imaging , Female , Male , Aged , Middle Aged , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Image Interpretation, Computer-Assisted/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...