Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 38.250
Filter
1.
Nat Commun ; 15(1): 4720, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38830847

ABSTRACT

Bioadhesive materials and patches are promising alternatives to surgical sutures and staples. However, many existing bioadhesives do not meet the functional requirements of current surgical procedures and interventions. Here, we present a translational patch material that exhibits instant adhesion to tissues (2.5-fold stronger than Tisseel, an FDA-approved fibrin glue), ultra-stretchability (stretching to >300% its original length without losing elasticity), compatibility with rapid photo-projection (<2 min fabrication time/patch), and ability to deliver therapeutics. Using our established procedures for the in silico design and optimization of anisotropic-auxetic patches, we created next-generation patches for instant attachment to tissues while conforming to a broad range of organ mechanics ex vivo and in vivo. Patches coated with extracellular vesicles derived from mesenchymal stem cells demonstrate robust wound healing capability in vivo without inducing a foreign body response and without the need for patch removal that can cause pain and bleeding. We further demonstrate a single material-based, void-filling auxetic patch designed for the treatment of lung puncture wounds.


Subject(s)
Tissue Adhesives , Wound Healing , Animals , Humans , Elasticity , Mesenchymal Stem Cells/cytology , Mice , Fibrin Tissue Adhesive , Male , Biocompatible Materials/chemistry
2.
J Acoust Soc Am ; 155(6): 3615-3626, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38833283

ABSTRACT

The current work investigated the effects of mass-loading the eardrum on wideband absorbance in humans. A non-invasive approach to mass-loading the eardrum was utilized in which water was placed on the eardrum via ear canal access. The mass-loaded absorbance was compared to absorbance measured for two alternative middle ear states: normal and stiffened. To stiffen the ear, subjects pressurized the middle ear through either exsufflation or insufflation concurrent with Eustachian tube opening. Mass-loading the eardrum was hypothesized to reduce high-frequency absorbance, whereas pressurizing the middle ear was hypothesized to reduce low- to mid-frequency absorbance. Discriminant linear analysis classification was performed to evaluate the utility of absorbance in differentiating between conditions. Water on the eardrum reduced absorbance over the 0.7- to 6-kHz frequency range and increased absorbance at frequencies below approximately 0.5 kHz; these changes approximated the pattern of changes reported in both hearing thresholds and stapes motion upon mass-loading the eardrum. Pressurizing the middle ear reduced the absorbance over the 0.125- to 4-kHz frequency range. Several classification models based on the absorbance in two- or three-frequency bands had accuracy exceeding 88%.


Subject(s)
Ear, Middle , Pressure , Tympanic Membrane , Humans , Male , Female , Tympanic Membrane/physiology , Tympanic Membrane/anatomy & histology , Ear, Middle/physiology , Ear, Middle/anatomy & histology , Adult , Young Adult , Elasticity , Acoustic Stimulation , Eustachian Tube/physiology , Eustachian Tube/anatomy & histology , Stapes/physiology , Water , Discriminant Analysis
3.
Med Eng Phys ; 127: 104158, 2024 May.
Article in English | MEDLINE | ID: mdl-38692761

ABSTRACT

BACKGROUND: The intervertebral disc exhibits not only strain rate dependence (viscoelasticity), but also significant asymmetry under tensile and compressive loads, which is of great significance for understanding the mechanism of lumbar disc injury under physiological loads. OBJECTIVE: In this study, the strain rate sensitive and tension-compression asymmetry of the intervertebral disc were analyzed by experiments and constitutive equation. METHOD: The Sheep intervertebral disc samples were divided into three groups, in order to test the strain rate sensitive mechanical behavior, and the internal displacement as well as pressure distribution. RESULTS: The tensile stiffness is one order of magnitude smaller than the compression stiffness, and the logarithm of the elastic modulus is approximately linear with the logarithm of the strain rate, showing obvious tension-compression asymmetry and rate-related characteristics. In addition, the sensitivity to the strain rate is the same under these two loading conditions. The stress-strain curves of unloading and loading usually do not coincide, and form a Mullins effect hysteresis loop. The radial displacement distribution is opposite between the anterior and posterior region, which is consistent with the stress distribution. By introducing the damage factor into ZWT constitutive equation, the rate-dependent viscoelastic and weakening behavior of the intervertebral disc can be well described.


Subject(s)
Compressive Strength , Intervertebral Disc , Stress, Mechanical , Animals , Intervertebral Disc/physiology , Sheep , Biomechanical Phenomena , Tensile Strength , Weight-Bearing , Elasticity
4.
Skin Res Technol ; 30(5): e13740, 2024 May.
Article in English | MEDLINE | ID: mdl-38720488

ABSTRACT

BACKGROUND: The human nail has a three-layered structure. Although it would be useful to quantitatively evaluate the changes in deformability of the nail due to various surface treatments, few studies have been conducted. METHODS: The effects of two types of surface treatment-a chemically acting nail softener and a physically acting nail strengthener-on the deformability of human fingernails were investigated. The Young's modulus of each plate of the nail samples before and after softening treatment was determined by nanoindentation. The Young's modulus of the strengthener was determined by conducting a three-point bending test on a polyethylene sheet coated with the strengthener. RESULTS: Young's modulus decreased in order from the top plate against the softening treatment time, and the structural elasticity for bending deformation (SEB) of the nail sample, which expresses the deformability against bending deformation independent of its external dimensions, decreased to 60% after 6 h of treatment. The Young's modulus of the nail strengthener was 244.5 MPa, which is less than 10% of the SEB of the nail. When the nail strengthener was applied to the nail surface, the SEB decreased to 73%, whereas the flexural rigidity increased to 117%. CONCLUSION: Changes in nail deformability caused by various surface treatments for softening and hardening were quantitatively evaluated successfully.


Subject(s)
Elastic Modulus , Nails , Surface Properties , Humans , Elastic Modulus/physiology , Nails/physiology , Female , Elasticity/physiology , Adult
5.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Article in English | MEDLINE | ID: mdl-38717086

ABSTRACT

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Subject(s)
Cornea , Elasticity , Intraocular Pressure , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia , Humans , Cornea/physiopathology , Cornea/surgery , Adult , Female , Male , Biomechanical Phenomena , Lasers, Excimer/therapeutic use , Keratomileusis, Laser In Situ/methods , Young Adult , Elasticity/physiology , Myopia/surgery , Myopia/physiopathology , Intraocular Pressure/physiology , Photorefractive Keratectomy/methods , Visual Acuity/physiology , Refraction, Ocular/physiology , Middle Aged , Prospective Studies , Corneal Surgery, Laser/methods , Corneal Topography
6.
Ter Arkh ; 96(3): 246-252, 2024 Apr 16.
Article in Russian | MEDLINE | ID: mdl-38713039

ABSTRACT

AIM: To determine and compare the work of breathing to overcome elastic resistance (Ael) in patients with bronchial asthma (BA) and chronic obstructive pulmonary disease (COPD) with similar changes in the elastic properties of the parenchyma in the same settings of ventilation disorders (grade 1). MATERIALS AND METHODS: Differences in the manifestations of similar changes in the elastic properties of the lungs in patients with BA and COPD were evaluated. To identify differences, a comparative study was conducted on Аel overcome in BA patients with positive bronchodilator (with salbutamol) and bronchoconstrictor (with methacholine) tests, with reduced and preserved bronchial conductance (groups 1 and 2, respectively), and in COPD patients with negative bronchodilator and bronchoconstrictor tests (group 3). All study patients showed a grade 1 lung ventilation disorder (a decrease in the one-second forced expiratory volume by 15-35%). The results were compared with each other and with the control group (group 4, healthy non-smokers). All study patients were comparable by age and sex. The respiration mechanics was studied using simultaneous registration of spirogram and transpulmonary pressure, and the parameters of bronchial conductance and ventilation were determined using body plethysmopressography using the Jager software and hardware system. RESULTS AND CONCLUSION: In COPD patients, Ael was significantly increased (p>0.05), whereas in both BA groups, it was unchanged. Increased elastic work of breathing in patients with COPD may be associated with the involvement of certain types of contractile elements, which are preserved in patients with BA at the initial stages of the disease.


Subject(s)
Asthma , Pulmonary Disease, Chronic Obstructive , Humans , Pulmonary Disease, Chronic Obstructive/physiopathology , Male , Female , Asthma/physiopathology , Middle Aged , Work of Breathing/physiology , Lung/physiopathology , Adult , Elasticity , Respiratory Function Tests/methods , Bronchodilator Agents/pharmacology , Bronchodilator Agents/administration & dosage
7.
Opt Lett ; 49(10): 2817-2820, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748169

ABSTRACT

Alteration in the elastic properties of biological tissues may indicate changes in the structure and components. Acoustic radiation force optical coherence elastography (ARF-OCE) can assess the elastic properties of the ocular tissues non-invasively. However, coupling the ultrasound beam and the optical beam remains challenging. In this Letter, we proposed an OCE method incorporating homolateral parallel ARF excitation for measuring the elasticity of the ocular tissues. An acoustic-optic coupling unit was established to reflect the ultrasound beam while transmitting the light beam. The ARF excited the ocular tissue in the direction parallel to the light beam from the same side of the light beam. We demonstrated the method on the agar phantoms, the porcine cornea, and the porcine retina. The results show that the ARF-OCE method can measure the elasticity of the cornea and the retina, resulting in higher detection sensitivity and a more extensive scanning range.


Subject(s)
Cornea , Elasticity Imaging Techniques , Phantoms, Imaging , Tomography, Optical Coherence , Elasticity Imaging Techniques/methods , Animals , Swine , Cornea/diagnostic imaging , Cornea/physiology , Tomography, Optical Coherence/methods , Elasticity , Retina/diagnostic imaging , Retina/physiology
8.
Gynecol Endocrinol ; 40(1): 2352139, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38733361

ABSTRACT

OBJECTIVE: The main purpose of this systematic review and meta-analysis was to investigate the diagnostic value of ultrasound elastography in the evaluation of polycystic ovary syndrome (PCOS). METHODS: A comprehensive and methodical investigation was carried out in the databases of PubMed, EMBASE, Cochrane, Scopus, Web of Science, and China National Knowledge Infrastructure, covering the entire duration of these databases until October 18, 2023. The primary purpose of this research was to evaluate and contrast ovarian tissue elasticity in people with and without PCOS. The elasticity of ovarian tissue was quantified using standardized mean difference (SMD). RESULTS: A total of eight studies were ultimately selected for systematic evaluation and meta-analysis. Five studies used shear wave elastography (SWE) as a diagnostic tool, and it was discovered that women with PCOS had higher levels of ovarian shear wave elasticity than their healthy counterparts. The SMD was determined to be 1.86 kilopascal (95% CI: 1.27 to 2.44). Three studies were conducted using strain elastography (SE) to compare the ovarian strain ratio of patients with PCOS to that of a healthy control group. The SMD for the PCOS group was 2.07 (95% CI: 1.79 to 2.34), which indicated that the ovarian strain ratio was significantly higher in that group. CONCLUSION: This systematic review and meta-analysis found that women with PCOS had stiffer ovarian tissue than women without the disorder. Ultrasound elastography may provide clinicians with value beyond 2D ultrasound in the diagnosis of PCOS.


Subject(s)
Elasticity Imaging Techniques , Polycystic Ovary Syndrome , Polycystic Ovary Syndrome/diagnostic imaging , Polycystic Ovary Syndrome/physiopathology , Humans , Elasticity Imaging Techniques/methods , Female , Ovary/diagnostic imaging , Elasticity
9.
Sci Rep ; 14(1): 11096, 2024 05 15.
Article in English | MEDLINE | ID: mdl-38750077

ABSTRACT

Skin tissue is recognized to exhibit rate-dependent mechanical behavior under various loading conditions. Here, we report that the full-thickness burn human skin exhibits rate-independent behavior under uniaxial tensile loading conditions. Mechanical properties, namely, ultimate tensile stress, ultimate tensile strain, and toughness, and parameters of Veronda-Westmann hyperelastic material law were assessed via uniaxial tensile tests. Univariate hypothesis testing yielded no significant difference (p > 0.01) in the distributions of these properties for skin samples loaded at three different rates of 0.3 mm/s, 2 mm/s, and 8 mm/s. Multivariate multiclass classification, employing a logistic regression model, failed to effectively discriminate samples loaded at the aforementioned rates, with a classification accuracy of only 40%. The median values for ultimate tensile stress, ultimate tensile strain, and toughness are computed as 1.73 MPa, 1.69, and 1.38 MPa, respectively. The findings of this study hold considerable significance for the refinement of burn care training protocols and treatment planning, shedding new light on the unique, rate-independent behavior of burn skin.


Subject(s)
Burns , Skin , Stress, Mechanical , Tensile Strength , Humans , Biomechanical Phenomena , Male , Female , Middle Aged , Adult , Elasticity , Skin Physiological Phenomena
10.
Crit Rev Biomed Eng ; 52(4): 17-28, 2024.
Article in English | MEDLINE | ID: mdl-38780103

ABSTRACT

In this study, we examine the behavior of articular cartilage equilibrated in a salt (NaCl) solution during non-Newtonian fluid flow that follows an Ostwald-de Waele model. A linearly elastic and isotropic rectangular strip of cartilage is considered for analysis. A continuum theory of mixtures has been employed to develop a coupled system of partial differential equations for the solid displacement and the fluid pressure by considering the important factor of the ion concentration by assuming the cartilage as a deformable porous media. The coupled system of partial differential equations is solved using the numerical method named method of lines. In most cases, shear-thinning fluid is compared to the shear-thickening fluid to magnify the difference. Graphical results show that shear-thickening fluids bring more solid deformation and shows less fluid pressure in comparison to the shear-thinning fluids.


Subject(s)
Cartilage, Articular , Pressure , Cartilage, Articular/physiology , Models, Biological , Humans , Ions , Animals , Rheology/methods , Elasticity , Sodium Chloride/chemistry , Viscosity , Porosity
11.
J R Soc Interface ; 21(214): 20240046, 2024 May.
Article in English | MEDLINE | ID: mdl-38774961

ABSTRACT

Many microorganisms propel themselves through complex media by deforming their flagella. The beat is thought to emerge from interactions between forces of the surrounding fluid, the passive elastic response from deformations of the flagellum and active forces from internal molecular motors. The beat varies in response to changes in the fluid rheology, including elasticity, but there are limited data on how systematic changes in elasticity alter the beat. This work analyses a related problem with fixed-strength driving force: the emergence of beating of an elastic planar filament driven by a follower force at the tip of a viscoelastic fluid. This analysis examines how the onset of oscillations depends on the strength of the force and viscoelastic parameters. Compared to a Newtonian fluid, it takes more force to induce the instability in viscoelastic fluids, and the frequency of the oscillation is higher. The linear analysis predicts that the frequency increases with the fluid relaxation time. Using numerical simulations, the model predictions are compared with experimental data on frequency changes in the bi-flagellated alga Chlamydomonas reinhardtii. The model shows the same trends in response to changes in both fluid viscosity and Deborah number and thus provides a possible mechanistic understanding of the experimental observations.


Subject(s)
Chlamydomonas reinhardtii , Elasticity , Models, Biological , Chlamydomonas reinhardtii/physiology , Viscosity , Flagella/physiology , Rheology
12.
Commun Biol ; 7(1): 617, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38778159

ABSTRACT

The question of whether material stiffness enhances cell adhesion and clustering is still open to debate. Results from the literature are seemingly contradictory, with some reports illustrating that adhesion increases with surface stiffness and others suggesting that the performance of a system of cells is curbed by high values of elasticity. To address the role of elasticity as a regulator in neuronal cell adhesion and clustering, we investigated the topological characteristics of networks of neurons on polydimethylsiloxane (PDMS) surfaces - with values of elasticity (E) varying in the 0.55-2.65 MPa range. Results illustrate that, as elasticity increases, the number of neurons adhering on the surface decreases. Notably, the small-world coefficient - a topological measure of networks - also decreases. Numerical simulations and functional multi-calcium imaging experiments further indicated that the activity of neuronal cells on soft surfaces improves for decreasing E. Experimental findings are supported by a mathematical model, that explains adhesion and clustering of cells on soft materials as a function of few parameters - including the Young's modulus and roughness of the material. Overall, results indicate that - in the considered elasticity interval - increasing the compliance of a material improves adhesion, improves clustering, and enhances communication of neurons.


Subject(s)
Cell Adhesion , Elasticity , Neurons , Neurons/physiology , Animals , Dimethylpolysiloxanes/chemistry , Surface Properties , Elastic Modulus , Cells, Cultured , Rats
13.
Biophys Chem ; 310: 107256, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38728807

ABSTRACT

Understanding the mechanisms by which drugs interact with cell membranes is crucial for unraveling the underlying biochemical and biophysical processes that occur on the surface of these membranes. Our research focused on studying the interaction between an ester-type derivative of tristearoyl uridine and model cell membranes composed of lipid monolayers at the air-water interface. For that, we selected a specific lipid to simulate nontumorigenic cell membranes, namely 1,2-dihexadecanoyl-sn-glycero-3-phospho-l-serine. We noted significant changes in the surface pressure-area isotherms, with a noticeable shift towards larger areas, which was lower than expected for ideal mixtures, indicating monolayer condensation. Furthermore, the viscoelastic properties of the interfacial film demonstrated an increase in both the elastic and viscous parameters for the mixed film. We also observed structural alterations using vibrational spectroscopy, which revealed an increase in the all-trans to gauche conformers ratio. This confirmed the stiffening effect of the prodrug on the lipid monolayer. In summary, this study indicates that this lipophilic prodrug significantly impacts the lipid monolayer's thermodynamic, rheological, electrical, and molecular characteristics. This information is crucial for understanding how the drug interacts with specific sites on the cellular membrane. It also has implications for drug delivery, as the drug's passage into the cytosol may involve traversing the lipid bilayer.


Subject(s)
Cell Membrane , Prodrugs , Uridine , Prodrugs/chemistry , Prodrugs/pharmacology , Prodrugs/metabolism , Cell Membrane/chemistry , Cell Membrane/metabolism , Uridine/chemistry , Uridine/pharmacology , Phosphatidylserines/chemistry , Thermodynamics , Surface Properties , Viscosity , Elasticity
14.
Eur Biophys J ; 53(4): 205-224, 2024 May.
Article in English | MEDLINE | ID: mdl-38703210

ABSTRACT

Unicellular organisms such as yeast can survive in very different environments, thanks to a polysaccharide wall that reinforces their extracellular membrane. This wall is not a static structure, as it is expected to be dynamically remodeled according to growth stage, division cycle, environmental osmotic pressure and ageing. It is therefore of great interest to study the mechanics of these organisms, but they are more difficult to study than other mammalian cells, in particular because of their small size (radius of a few microns) and their lack of an adhesion machinery. Using flat cantilevers, we perform compression experiments on single yeast cells (S. cerevisiae) on poly-L-lysine-coated grooved glass plates, in the limit of small deformation using an atomic force microscope (AFM). Thanks to a careful decomposition of force-displacement curves, we extract local scaling exponents that highlight the non-stationary characteristic of the yeast behavior upon compression. Our multi-scale nonlinear analysis of the AFM force-displacement curves provides evidence for non-stationary scaling laws. We propose to model these phenomena based on a two-component elastic system, where each layer follows a different scaling law..


Subject(s)
Elasticity , Microscopy, Atomic Force , Models, Biological , Saccharomyces cerevisiae , Saccharomyces cerevisiae/cytology , Polylysine/chemistry , Compressive Strength
15.
Nature ; 629(8014): 1047-1054, 2024 May.
Article in English | MEDLINE | ID: mdl-38778108

ABSTRACT

Wireless modules that provide telecommunications and power-harvesting capabilities enabled by radio-frequency (RF) electronics are vital components of skin-interfaced stretchable electronics1-7. However, recent studies on stretchable RF components have demonstrated that substantial changes in electrical properties, such as a shift in the antenna resonance frequency, occur even under relatively low elastic strains8-15. Such changes lead directly to greatly reduced wireless signal strength or power-transfer efficiency in stretchable systems, particularly in physically dynamic environments such as the surface of the skin. Here we present strain-invariant stretchable RF electronics capable of completely maintaining the original RF properties under various elastic strains using a 'dielectro-elastic' material as the substrate. Dielectro-elastic materials have physically tunable dielectric properties that effectively avert frequency shifts arising in interfacing RF electronics. Compared with conventional stretchable substrate materials, our material has superior electrical, mechanical and thermal properties that are suitable for high-performance stretchable RF electronics. In this paper, we describe the materials, fabrication and design strategies that serve as the foundation for enabling the strain-invariant behaviour of key RF components based on experimental and computational studies. Finally, we present a set of skin-interfaced wireless healthcare monitors based on strain-invariant stretchable RF electronics with a wireless operational distance of up to 30 m under strain.


Subject(s)
Elasticity , Electronics , Equipment Design , Radio Waves , Skin , Stress, Mechanical , Wearable Electronic Devices , Wireless Technology , Humans , Electronics/instrumentation , Wireless Technology/instrumentation , Monitoring, Physiologic/instrumentation
16.
Sci Adv ; 10(19): eadl1586, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38718128

ABSTRACT

Viscoelastic transformation of tissue drives aberrant cellular functions and is an early biomarker of disease pathogenesis. Tissues scale a range of viscoelastic moduli, from biofluids to bone. Moreover, viscoelastic behavior is governed by the frequency at which tissue is probed, yielding distinct viscous and elastic responses modulated over a wide frequency band. Existing tools do not quantify wideband viscoelastic spectra in tissues, leaving a vast knowledge gap. We present wideband laser speckle rheological microscopy (WB-SHEAR) that reveals elastic and viscous response over sub-megahertz frequencies previously not investigated in tissue. WB-SHEAR uses an optical, noncontact approach to quantify wideband viscoelastic spectra in specimens spanning a range of moduli from low-viscosity fibrin to highly elastic bone. Via laser scanning, micromechanical imaging is enabled to access wideband viscoelastic spectra in heterogeneous tumor specimens with high spatial resolution (25 micrometers). The ability to interrogate the viscoelastic landscape of diverse biospecimens could transform our understanding of mechanobiological processes in various diseases.


Subject(s)
Elasticity , Rheology , Viscosity , Rheology/methods , Humans , Animals , Lasers , Microscopy/methods
17.
BMC Oral Health ; 24(1): 619, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38807138

ABSTRACT

PURPOSE: The aim of this in vitro study was to evaluate the changes the rheological properties of some soft lining materials, to compare the rheological properties and viscoelastic behaviour at different temperatures. MATERIALS AND METHODS: Five soft lining materials (acrylic and silicone based) were used. the storage modulus (G'), loss modulus (G"), tan delta (tan δ) and complex viscosity (η') were chosen and for each material, measurements were repeated at 23, 33 and 37  °C, using an oscillating rheometer. All data were statistically analyzed using the Mann Whitney U test, Kruskal Wallis test and Conover's Multiple Comparison test at the significance level of 0.05. RESULTS: Soft lining materials had different viscoelastic properties and most of the materials showed different rheological behavior at 23, 33 and 37  °C. At the end of the test (t¹5), at all the temperatures, Sofreliner Tough M had the highest storage modulus values while Visco Gel had the highest loss Tan delta values. CONCLUSIONS: There were significant changes in the rheological parameters of all the materials. Also temperature affected the initial rheological properties, and polymerization reaction of all the materials, depending on temperature increase. CLINICAL IMPLICATIONS: Temperature affected the initial rheological properties, and polymerization reaction of soft denture liner materials, and clinical inferences should be drawn from such studies conducted. It can be recommended to utilize viscoelastic acrylic-based temporary soft lining materials with lower storage modulus, higher tan delta value, and high viscosity in situations where pain complaint persists and tissue stress is extremely significant, provided that they are replaced often.


Subject(s)
Acrylic Resins , Materials Testing , Rheology , Temperature , Viscosity , Acrylic Resins/chemistry , Elasticity , Denture Liners , Elastic Modulus , Dental Cavity Lining , Silicones/chemistry , Polymerization , Humans , Oscillometry
18.
Food Chem ; 452: 139436, 2024 Sep 15.
Article in English | MEDLINE | ID: mdl-38749144

ABSTRACT

The oil phase obtained by blending and oleogel methods has potential for the production of non­hydrogenated and low-saturated puff pastry margarine, thereby reducing intakes of both types of dietary fat. The crystal form, microstructure, rheology, and baking applications of puff pastry margarines prepared with anhydrous milk fat (AMF)/palm stearin (POs), POs/palm oil (PO), beef tallow (BT)/PO, or AMF/POs/diacetyl tartaric acid ester of mono(di)glycerides (DATEM) oleogels were investigated using X-ray scattering, polarized light microscope, and rheometer, respectively. All margarines exhibited ß'-form crystal and strongly viscoelastic at low strain. With the addition of DATEM oleogel, their crystal microstructure became more uniform and finer, and the croissants were less hard (1690) and chewiness (160). The chewiness of croissants produced using the margarines was significantly improved with POs content. The theoretical basis for preparation and application in non­hydrogenated and low-saturated puff pastry margarine was provided in the present study.


Subject(s)
Margarine , Rheology , Margarine/analysis , Viscosity , Animals , Cooking , Elasticity , Milk/chemistry , Cattle , Fats/chemistry , Palm Oil/chemistry , Organic Chemicals/chemistry , Organic Chemicals/analysis
19.
Int J Mol Sci ; 25(10)2024 May 14.
Article in English | MEDLINE | ID: mdl-38791375

ABSTRACT

The presence of molecular mutations in colorectal cancer (CRC) is a decisive factor in selecting the most effective first-line therapy. However, molecular analysis is routinely performed only in a limited number of patients with remote metastases. We propose to use tissue stiffness as a marker of the presence of molecular mutations in CRC samples. For this purpose, we applied compression optical coherence elastography (C-OCE) to calculate stiffness values in regions corresponding to specific CRC morphological patterns (n = 54). In parallel to estimating stiffness, molecular analysis from the same zones was performed to establish their relationships. As a result, a high correlation between the presence of KRAS/NRAS/BRAF driver mutations and high stiffness values was revealed regardless of CRC morphological pattern type. Further, we proposed threshold stiffness values for label-free targeted detection of molecular alterations in CRC tissues: for KRAS, NRAS, or BRAF driver mutation-above 803 kPa (sensitivity-91%; specificity-80%; diagnostic accuracy-85%), and only for KRAS driver mutation-above 850 kPa (sensitivity-90%; specificity-88%; diagnostic accuracy-89%). To conclude, C-OCE estimation of tissue stiffness can be used as a clinical diagnostic tool for preliminary screening of genetic burden in CRC tissues.


Subject(s)
Biomarkers, Tumor , Colorectal Neoplasms , Elasticity Imaging Techniques , GTP Phosphohydrolases , Mutation , Proto-Oncogene Proteins B-raf , Proto-Oncogene Proteins p21(ras) , Humans , Colorectal Neoplasms/genetics , Colorectal Neoplasms/pathology , Colorectal Neoplasms/diagnosis , Elasticity Imaging Techniques/methods , Biomarkers, Tumor/genetics , Proto-Oncogene Proteins B-raf/genetics , Proto-Oncogene Proteins p21(ras)/genetics , GTP Phosphohydrolases/genetics , Female , Male , Elasticity , Aged , Membrane Proteins/genetics , Middle Aged
20.
J Biomech ; 169: 112135, 2024 May.
Article in English | MEDLINE | ID: mdl-38744145

ABSTRACT

Articular cartilage exhibits site-specific biomechanical properties. However, no study has comprehensively characterized site-specific cartilage properties from the same knee joints at different stages of osteoarthritis (OA). Cylindrical osteochondral explants (n = 381) were harvested from donor-matched lateral and medial tibia, lateral and medial femur, patella, and trochlea of cadaveric knees (N = 17). Indentation test was used to measure the elastic and viscoelastic mechanical properties of the samples, and Osteoarthritis Research Society International (OARSI) grading system was used to categorize the samples into normal (OARSI 0-1), early OA (OARSI 2-3), and advanced OA (OARSI 4-5) groups. OA-related changes in cartilage mechanical properties were site-specific. In the lateral and medial tibia and trochlea sites, equilibrium, instantaneous and dynamic moduli were higher (p < 0.001) in normal tissue than in early and advanced OA tissue. In lateral and medial femur, equilibrium, instantaneous and dynamic moduli were smaller in advanced OA, but not in early OA, than in normal tissue. The phase difference (0.1-0.25 Hz) between stress and strain was significantly smaller (p < 0.05) in advanced OA than in normal tissue across all sites except medial tibia. Our results indicated that in contrast to femoral and patellar cartilage, equilibrium, instantaneous and dynamic moduli of the tibia and trochlear cartilage decreased in early OA. These may suggest that the tibia and trochlear cartilage degrades faster than the femoral and patellar cartilage. The information is relevant for developing site-specific computational models and engineered cartilage constructs.


Subject(s)
Cartilage, Articular , Knee Joint , Osteoarthritis, Knee , Humans , Cartilage, Articular/physiopathology , Cartilage, Articular/physiology , Cartilage, Articular/pathology , Knee Joint/physiopathology , Aged , Osteoarthritis, Knee/physiopathology , Male , Female , Middle Aged , Biomechanical Phenomena , Elasticity , Viscosity , Tibia/physiopathology , Femur/physiopathology , Femur/physiology , Aged, 80 and over , Adult , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...