Zhonghua Yi Xue Za Zhi ; 104(21): 1987-1993, 2024 Jun 04.
Article in Chinese | MEDLINE | ID: mdl-38825942

ABSTRACT

Objective: To test the new method of iMAX (the minimum stimulus current that elicits the maximum compound muscle action potential amplitude) electrodiagnosis, verify the feasibility of this method in evaluating the excitability of peripheral motor axons, and preliminarily explore the clinical application value. Methods: This study was a cross-sectional study. A total of 50 healthy subjects were recruited from the outpatient department of Peking University Third Hospital from June 2022 to March 2023, including 25 males and 25 females, aged 25-68 (48±8) years. Eleven patients with Charcot-Marie-Pain-1A (CMT1A), 7 males and 4 females, aged 19-55 (41±13) years and 21 patients with diabetic peripheral neuropathy (DPN), 10 males and 11 females, aged 28-79 (53±16) years were enrolled in this study. iMAX of bilateral median nerves, ulnar nerves and peroneal nerves were detected in all patients. Repeatable motor responses with minimum motor threshold and amplitude of at least 0.1 mV and the minimum stimulus current intensity, at which the maximum compound muscle action potential amplitude is elicited, were measured respectively [1 mA increment is called (iUP) and, 0.1 mA adjustment is called (iMAX)].Comparison of the parameters: the parameters of threshold, iUP and iMAX were compared among different age groups, genders and sides, body mass index(BMI) values and detection time , as well as between CMT1A patients, DPN patients and healthy subjects. Results: In healthy subjects, the threshold, iUP value and iMAX value were (1.8±0.7) mA, (4.4±1.2) mA, and (4.2±1.3) mA respectively; ulnar nerve (3.1±1.6) mA, (6.8±3.2) mA, (6.4±3.2) mA; peroneal nerve (3.7±2.0) mA, (7.8±2.8) mA, (7.4±2.9) mA. There were statistically significant differences in threshold, iUP value and iMAX value among different age groups (all P<0.001).With the increase of age, there was a trend of increasing threshold, iUP, and iMAX values in different nerves, and the differences are statistically significant (all P<0.001). There were no significant differences in gender, side and detection time threshold, iUP value and iMAX value (all P>0.05). The parameters of healthy subjects with high BMI value were higher than those of healthy subjects with low BMI value(all P<0.05). Compared with the healthy subjects, the parameters of 11 CMT1A patients were significantly increased (all P<0.05), and the parameters of 21 DPN patients were slightly increased (P<0.05). Conclusion: The new iMAX method reflects the excitability of motor axons and early axonal dysfunction, which is an important supplement to the traditional nerve conduction, and can be used to monitor motor axon excitability disorders.


Subject(s)
Action Potentials , Electrodiagnosis , Humans , Female , Male , Middle Aged , Adult , Cross-Sectional Studies , Aged , Electrodiagnosis/methods , Motor Neurons/physiology , Median Nerve/physiopathology , Neural Conduction , Ulnar Nerve , Diabetic Neuropathies/diagnosis , Diabetic Neuropathies/physiopathology , Peripheral Nerves/physiopathology , Electric Stimulation , Electromyography
2.
J Acoust Soc Am ; 155(6): 3589-3599, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38829154

ABSTRACT

Frequency importance functions (FIFs) for simulated bimodal hearing were derived using sentence perception scores measured in quiet and noise. Acoustic hearing was simulated using low-pass filtering. Electric hearing was simulated using a six-channel vocoder with three input frequency ranges, resulting in overlap, meet, and gap maps, relative to the acoustic cutoff frequency. Spectral holes present in the speech spectra were created within electric stimulation by setting amplitude(s) of channels to zero. FIFs were significantly different between frequency maps. In quiet, the three FIFs were similar with gradually increasing weights with channels 5 and 6 compared to the first three channels. However, the most and least weighted channels slightly varied depending on the maps. In noise, the patterns of the three FIFs were similar to those in quiet, with steeper increasing weights with channels 5 and 6 compared to the first four channels. Thus, channels 5 and 6 contributed to speech perception the most, while channels 1 and 2 contributed the least, regardless of frequency maps. Results suggest that the contribution of cochlear implant frequency bands for bimodal speech perception depends on the degree of frequency overlap between acoustic and electric stimulation and if noise is absent or present.


Subject(s)
Acoustic Stimulation , Cochlear Implants , Electric Stimulation , Noise , Speech Perception , Humans , Noise/adverse effects , Cochlear Implantation/instrumentation , Persons With Hearing Impairments/psychology , Persons With Hearing Impairments/rehabilitation , Perceptual Masking , Adult
3.
Nat Commun ; 15(1): 4721, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38830884

ABSTRACT

Optoelectronic neural interfaces can leverage the photovoltaic effect to convert light into electrical current, inducing charge redistribution and enabling nerve stimulation. This method offers a non-genetic and remote approach for neuromodulation. Developing biodegradable and efficient optoelectronic neural interfaces is important for achieving transdermal stimulation while minimizing infection risks associated with device retrieval, thereby maximizing therapeutic outcomes. We propose a biodegradable, flexible, and miniaturized silicon-based neural interface capable of transdermal optoelectronic stimulation for neural modulation and nerve regeneration. Enhancing the device interface with thin-film molybdenum significantly improves the efficacy of neural stimulation. Our study demonstrates successful activation of the sciatic nerve in rodents and the facial nerve in rabbits. Moreover, transdermal optoelectronic stimulation accelerates the functional recovery of injured facial nerves.


Subject(s)
Nerve Regeneration , Sciatic Nerve , Animals , Rabbits , Nerve Regeneration/physiology , Nerve Regeneration/drug effects , Sciatic Nerve/physiology , Facial Nerve/physiology , Peripheral Nerves/physiology , Male , Rats , Silicon/chemistry , Rats, Sprague-Dawley , Electric Stimulation
4.
Med Eng Phys ; 127: 104170, 2024 May.
Article in English | MEDLINE | ID: mdl-38692767

ABSTRACT

Recently, functional Near-Infrared Spectroscopy (fNIRS) was applied to obtain, non-invasively, the human peri­spinal Neuro-Vascular Response (NVR) under a non-noxious electrical stimulation of a peripheral nerve. This method allowed the measurements of changes in the concentration of oxyhemoglobin (O2Hb) and deoxyhemoglobin (HHb) from the peri­spinal vascular network. However, there is a lack of clarity about the potential differences in perispinal NVR recorded by the different fNIRS technologies currently available. In this work, the two main noninvasive fNIRS technologies were compared, i.e., LED and LASER-based. The recording of the human peri­spinal NVR induced by non-noxious electrical stimulation of a peripheral nerve was recorded simultaneously at C7 and T10 vertebral levels. The amplitude, rise time, and full width at half maximum duration of the perispinal NVRs were characterized in healthy volunteers and compared between both systems. The main difference was that the LED-based system shows about one order of magnitude higher values of amplitude than the LASER-based system. No statistical differences were found for rise time and for duration parameters (at thoracic level). The comparison of point-to-point wave patterns did not show significant differences between both systems. In conclusion, the peri­spinal NRV response obtained by different fNIRS technologies was reproducible, and only the amplitude showed differences, probably due to the power of the system which should be considered when assessing the human peri­spinal vascular network.


Subject(s)
Lasers , Spectroscopy, Near-Infrared , Spinal Cord , Humans , Spectroscopy, Near-Infrared/methods , Male , Spinal Cord/blood supply , Spinal Cord/diagnostic imaging , Spinal Cord/physiology , Adult , Female , Young Adult , Electric Stimulation , Hemoglobins/analysis , Hemoglobins/metabolism
5.
Sci Adv ; 10(19): eadl1230, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38718109

ABSTRACT

The spinal cord is crucial for transmitting motor and sensory information between the brain and peripheral systems. Spinal cord injuries can lead to severe consequences, including paralysis and autonomic dysfunction. We introduce thin-film, flexible electronics for circumferential interfacing with the spinal cord. This method enables simultaneous recording and stimulation of dorsal, lateral, and ventral tracts with a single device. Our findings include successful motor and sensory signal capture and elicitation in anesthetized rats, a proof-of-concept closed-loop system for bridging complete spinal cord injuries, and device safety verification in freely moving rodents. Moreover, we demonstrate potential for human application through a cadaver model. This method sees a clear route to the clinic by using materials and surgical practices that mitigate risk during implantation and preserve cord integrity.


Subject(s)
Spinal Cord Injuries , Spinal Cord , Animals , Spinal Cord/physiology , Rats , Spinal Cord Injuries/therapy , Spinal Cord Injuries/physiopathology , Humans , Electric Stimulation/methods , Electrodes, Implanted
6.
Sci Rep ; 14(1): 10252, 2024 05 04.
Article in English | MEDLINE | ID: mdl-38704459

ABSTRACT

About one in three critically ill patients requires mechanical ventilation (MV). Prolonged MV, however, results in diaphragmatic weakness, which itself is associated with delayed weaning and increased mortality. Inducing active diaphragmatic contraction via electrical phrenic nerve stimulation (PNS) not only provides the potential to reduce diaphragmatic muscular atrophy but also generates physiological-like ventilation and therefore offers a promising alternative to MV. Reasons why PNS is not yet used in critical care medicine are high procedural invasiveness, insufficient evidence, and lack of side-by-side comparison to MV. This study aims to establish a minimal-invasive percutaneous, bilateral electrode placement approach for sole PNS breathing and thereby enable, for the first time, a breath-by-breath comparison to MV. Six juvenile German Landrace pigs received general anesthesia and orotracheal intubation. Following the novel ultrasound-guided, landmark-based, 4-step approach, two echogenic needles per phrenic nerve were successfully placed. Stimulation effectiveness was evaluated measuring tidal volume, diaphragmatic thickening and tomographic electrical impedance in a breath-by-breath comparison to MV. Following sufficient bilateral phrenic nerve stimulation in all pigs, PNS breaths showed a 2.2-fold increase in diaphragmatic thickening. It induced tidal volumes in the lung-protective range by negative pressure inspiration and improved dorso-caudal regional ventilation in contrast to MV. Our study demonstrated the feasibility of a novel ultrasound-guided, percutaneous phrenic nerve stimulation approach, which generated sufficient tidal volumes and showed more resemblance to physiological breathing than MV in a breath-by-breath comparison.


Subject(s)
Diaphragm , Phrenic Nerve , Respiration, Artificial , Animals , Phrenic Nerve/physiology , Respiration, Artificial/methods , Swine , Pilot Projects , Diaphragm/innervation , Diaphragm/physiology , Tidal Volume , Electric Stimulation Therapy/methods , Transcutaneous Electric Nerve Stimulation/methods , Electric Stimulation/methods
7.
Sci Rep ; 14(1): 10422, 2024 05 07.
Article in English | MEDLINE | ID: mdl-38710727

ABSTRACT

Anticipating positive outcomes is a core cognitive function in the process of reward prediction. However, no neurophysiological method objectively assesses reward prediction in basic medical research. In the present study, we established a physiological paradigm using cortical direct current (DC) potential responses in rats to assess reward prediction. This paradigm consisted of five daily 1-h sessions with two tones, wherein the rewarded tone was followed by electrical stimulation of the medial forebrain bundle (MFB) scheduled at 1000 ms later, whereas the unrewarded tone was not. On day 1, both tones induced a negative DC shift immediately after auditory responses, persisting up to MFB stimulation. This negative shift progressively increased and peaked on day 4. Starting from day 3, the negative shift from 600 to 1000 ms was significantly larger following the rewarded tone than that following the unrewarded tone. This negative DC shift was particularly prominent in the frontal cortex, suggesting its crucial role in discriminative reward prediction. During the extinction sessions, the shift diminished significantly on extinction day 1. These findings suggest that cortical DC potential is related to reward prediction and could be a valuable tool for evaluating animal models of depression, providing a testing system for anhedonia.


Subject(s)
Extinction, Psychological , Reward , Animals , Rats , Male , Extinction, Psychological/physiology , Electric Stimulation , Acoustic Stimulation , Medial Forebrain Bundle/physiology , Rats, Sprague-Dawley
8.
Trends Hear ; 28: 23312165241248973, 2024.
Article in English | MEDLINE | ID: mdl-38717441

ABSTRACT

To preserve residual hearing during cochlear implant (CI) surgery it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring). A promising method is electrocochleography (ECochG). Within this project the relations between intracochlear ECochG recordings, position of the recording contact in the cochlea with respect to anatomy and frequency and preservation of residual hearing were investigated. The aim was to better understand the changes in ECochG signals and whether these are due to the electrode position in the cochlea or to trauma generated during insertion. During and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed using the CI electrode (MED-EL). During insertion, the recordings were performed at discrete insertion steps on electrode contact 1. After insertion as well as postoperatively the recordings were performed at different electrode contacts. The electrode location in the cochlea during insertion was estimated by mathematical models using preoperative clinical imaging, the postoperative location was measured using postoperative clinical imaging. The recordings were analyzed from six adult CI recipients. In the four patients with good residual hearing in the low frequencies the signal amplitude rose with largest amplitudes being recorded closest to the generators of the stimulation frequency, while in both cases with severe pantonal hearing losses the amplitude initially rose and then dropped. This might be due to various reasons as discussed in the following. Our results indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.


Subject(s)
Audiometry, Evoked Response , Cochlea , Cochlear Implantation , Cochlear Implants , Humans , Cochlea/surgery , Cochlea/physiology , Cochlea/physiopathology , Cochlear Implantation/instrumentation , Cochlear Implantation/methods , Audiometry, Evoked Response/methods , Middle Aged , Aged , Male , Female , Hearing/physiology , Adult , Treatment Outcome , Predictive Value of Tests , Electric Stimulation , Persons With Hearing Impairments/rehabilitation , Persons With Hearing Impairments/psychology , Auditory Threshold/physiology
9.
Physiol Res ; 73(2): 285-294, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38710059

ABSTRACT

This study aimed to determine whether electrical stimulation-based twitch exercise is effective in inhibiting the progression of immobilization-induced muscle fibrosis. 19 Wistar rats were randomly divided into a control group (n=6), an immobilization group (n=6; with immobilization only), and a Belt group (n=7; with immobilization and twitch exercise through the belt electrode device, beginning 2 weeks after immobilization). The bilateral soleus muscles were harvested after the experimental period. The right soleus muscles were used for histological analysis, and the left soleus muscles were used for biochemical and molecular biological analysis. As a result, in the picrosirius red images, the perimysium and endomysium were thicker in both the immobilization and Belt groups compared to the control group. However, the perimysium and endomysium thickening were suppressed in the Belt group. The hydroxyproline content and alpha-SMA, TGF-beta1, and HIF-1alpha mRNA expressions were significantly higher in the immobilization and belt groups than in the control group. These expressions were significantly lower in the Belt group than in the immobilization group. The capillary-to-myofiber ratio and the mRNA expressions of VEGF and PGC-1alpha were significantly lower in the immobilization and belt groups than in the control group, these were significantly higher in the Belt group than in the immobilization group. From these results, Electrical stimulation-based twitch exercise using the belt electrode device may prevent the progression of immobilization-induced muscle fibrosis caused by downregulating PGC-1alpha/VEGF pathway, we surmised that this intervention strategy might be effective against the progression of muscle contracture. Keywords: Immobilization, Skeletal muscle, Fibrosis, Electrical stimulation-based twitch exercise, PGC-1alpha/VEGF pathway.


Subject(s)
Down-Regulation , Fibrosis , Muscle, Skeletal , Peroxisome Proliferator-Activated Receptor Gamma Coactivator 1-alpha , Vascular Endothelial Growth Factor A , Animals , Male , Rats , Disease Progression , Electric Stimulation , Electric Stimulation Therapy/methods , Muscle, Skeletal/metabolism , Muscle, Skeletal/pathology , Muscular Diseases/metabolism , Muscular Diseases/pathology , Muscular Diseases/prevention & control , Muscular Diseases/etiology , Peroxisome Proliferator-Activated Receptor Gamma Coactivator 1-alpha/metabolism , Physical Conditioning, Animal/physiology , Rats, Wistar , Signal Transduction/physiology , Vascular Endothelial Growth Factor A/metabolism , Vascular Endothelial Growth Factor A/genetics
10.
Biofabrication ; 16(3)2024 May 28.
Article in English | MEDLINE | ID: mdl-38744312

ABSTRACT

Electrodes are crucial for controlling the movements of biohybrid robots, but their external placement outside muscle tissue often leads to inefficient and non-selective stimulation of nearby biohybrid actuators. To address this, we propose embedding pillar electrodes within the skeletal muscle tissue, resulting in enhanced contraction of the target muscle without affecting the neighbor tissue with a 4 mm distance. We use finite element method simulations to establish a selectivity model, correlating the VIE(volume integration of electric field intensity within muscle tissue) with actual contractile distances under different amplitudes of electrical pulses. The simulated selective index closely aligns with experimental results, showing the potential of pillar electrodes for effective and selective biohybrid actuator stimulation. In experiments, we validated that the contractile distance and selectivity achieved with these pillar electrodes exceed conventional Au rod electrodes. This innovation has promising implications for building biohybrid robots with densely arranged muscle tissue, ultimately achieving more human-like movements. Additionally, our selectivity model offers valuable predictive tools for assessing electrical stimulation effects with different electrode designs.


Subject(s)
Electric Stimulation , Electrodes , Muscle Contraction , Muscle, Skeletal , Muscle, Skeletal/physiology , Muscle Contraction/physiology , Animals , Robotics/instrumentation , Finite Element Analysis , Humans
11.
J Exp Biol ; 227(10)2024 May 15.
Article in English | MEDLINE | ID: mdl-38699818

ABSTRACT

Little is known regarding the precise muscle, bone and joint actions resulting from individual and simultaneous muscle activation(s) of the lower limb. An in situ experimental approach is described herein to control the muscles of the rabbit lower hindlimb, including the medial and lateral gastrocnemius, soleus, plantaris and tibialis anterior. The muscles were stimulated using nerve-cuff electrodes placed around the innervating nerves of each muscle. Animals were fixed in a stereotactic frame with the ankle angle set at 90 deg. To demonstrate the efficacy of the experimental technique, isometric plantarflexion torque was measured at the 90 deg ankle joint angle at a stimulation frequency of 100, 60 and 30 Hz. Individual muscle torque and the torque produced during simultaneous activation of all plantarflexor muscles are presented for four animals. These results demonstrate that the experimental approach was reliable, with insignificant variation in torque between repeated contractions. The experimental approach described herein provides the potential for measuring a diverse array of muscle properties, which is important to improve our understanding of musculoskeletal biomechanics.


Subject(s)
Hindlimb , Muscle, Skeletal , Torque , Animals , Rabbits , Muscle, Skeletal/physiology , Muscle, Skeletal/innervation , Hindlimb/physiology , Biomechanical Phenomena , Electric Stimulation , Male
12.
Prog Orthod ; 25(1): 17, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38735912

ABSTRACT

BACKGROUND: Low-intensity electrical stimulation (LIES) is considered a relatively recent technology that has received little attention in orthodontics as a method of acceleration. This study aimed to evaluate patient-reported outcome measures when LIES is used to accelerate the en-masse retraction of the upper anterior teeth. MATERIALS AND METHODS: The sample consisted of 40 patients (8 males, 32 females; mean age 21.1 ± 2.3 years), with Class II division I malocclusion who required extraction of the first premolars to retract upper anterior teeth. They were randomly assigned to the LIES group (n = 20) and the conventional en-masse retraction group (CER; n = 20). Patient responses regarding pain, discomfort, burning sensation, swelling, chewing difficulty, speech difficulty, and painkillers' consumption were recorded at these nine assessment times: 24 h (T1), 3 days (T2), and 7 days (T3) after force application, then in the second month after 24 h (T4), 3 days (T5), and 7 days (T6) of force re-activation, and finally after 24 h (T7), 3 days (T8), and 7 days (T9) of force re-activation in the third month. RESULTS: The mean values of pain perception were smaller in the LIES group than those in the CER group at all assessment times with no statistically significant differences between the two groups except during the second and third months (T5, T6, T8, and T9; P < 0.005). However, discomfort mean values were greater in the LIES group with significant differences compared to CER group during the first week of the follow-up only (T1, T2, and T3; P < 0.005). Burning sensation levels were very mild in the LIES group, with significant differences between the two groups at T1 and T2 only (P < 0.001). Speech difficulty was significantly greater in the LIES group compared to CER group at all studied times (P < 0.001). High levels of satisfaction and acceptance were reported in both groups, without any significant difference. CONCLUSION: Both the LIES-based acceleration of en-masse retraction of upper anterior teeth and the conventional retraction were accompanied by mild to moderate pain, discomfort, and chewing difficulty on the first day of retraction. These sensations gradually decreased and almost disappeared over a week after force application or re-activation. TRIAL REGISTRATION: ClinicalTrials.gov, ClinicalTrials.gov, NCT05920525. Registered 17 June 2023 - retrospectively registered, http://clinicaltrials.gov/study/NCT05920525?term=NCT05920525&rank=1 .


Subject(s)
Patient Reported Outcome Measures , Tooth Movement Techniques , Humans , Female , Male , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Young Adult , Malocclusion, Angle Class II/therapy , Tooth Extraction , Bicuspid , Electric Stimulation/methods , Mastication/physiology , Incisor , Maxilla , Pain Measurement
13.
PLoS One ; 19(5): e0302970, 2024.
Article in English | MEDLINE | ID: mdl-38728244

ABSTRACT

Hematopoietic stem cell transplantation is a common life-saving treatment for hematologic malignancies, though can lead to long-term functional impairment, fatigue, muscle atrophy, with decreased quality of life. Although traditional exercise has helped reduce these effects, it is inconsistently recommended and infrequently maintained, and most patients remain sedentary during and after treatment. There is need for alternative rehabilitation strategies, like neuromuscular electrical stimulation, that may be more amenable to the capabilities of hematopoietic stem cell transplant recipients. Patients receiving autologous HCT are being enroled in a randomized controlled trial with 1:1 (neuromuscular electrical stimulation:sham) design stratified by diagnosis and sex. Physical function, body composition, quality of life, and fatigue are assessed prior to hematopoietic stem cell transplant (prior to initiating preparatory treatment) and 24±5 days post hematopoietic stem cell transplant (Follow-up 1); physical function and quality of life are also assessed 6-months post hematopoietic stem cell transplant (Follow-up 2). The primary outcome is between-group difference in the 6-minute walk test change scores (Follow-up 1-Pre-transplant; final enrolment goal N = 23/group). We hypothesize that 1) neuromuscular electrical stimulation will attenuate hematopoietic stem cell transplant-induced adverse effects on physical function, muscle mass, quality of life, and fatigue compared to sham at Follow-up 1, and 2) Pre-transplant physical function will significantly predict fatigue and quality of life at Follow-up 2. We will also describe feasibility and acceptability of neuromuscular electrical stimulation during hematopoietic stem cell transplant. This proposal will improve rehabilitative patient care and quality of life by determining efficacy and feasibility of a currently underutilized therapeutic strategy aimed at maintaining daily function and reducing the impact of a potent and widely used cancer treatment. This trial is registered with clinicaltrials.gov (NCT04364256).


Subject(s)
Electric Stimulation Therapy , Hematopoietic Stem Cell Transplantation , Quality of Life , Humans , Hematopoietic Stem Cell Transplantation/methods , Electric Stimulation Therapy/methods , Male , Female , Adult , Electric Stimulation/methods , Fatigue/therapy , Middle Aged , Hematologic Neoplasms/therapy , Transplantation, Autologous , Body Composition
14.
Nat Commun ; 15(1): 4133, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755124

ABSTRACT

Conductive cardiac patches can rebuild the electroactive microenvironment for the infarcted myocardium but their repair effects benefit by carried seed cells or drugs. The key to success is the effective integration of electrical stimulation with the microenvironment created by conductive cardiac patches. Besides, due to the concerns in a high re-admission ratio of heart patients, a remote medicine device will underpin the successful repair. Herein, we report a miniature self-powered biomimetic trinity triboelectric nanogenerator with a unique double-spacer structure that unifies energy harvesting, therapeutics, and diagnosis in one cardiac patch. Trinity triboelectric nanogenerator conductive cardiac patches improve the electroactivity of the infarcted heart and can also wirelessly monitor electrocardiosignal to a mobile device for diagnosis. RNA sequencing analysis from rat hearts reveals that this trinity cardiac patches mainly regulates cardiac muscle contraction-, energy metabolism-, and vascular regulation-related mRNA expressions in vivo. The research is spawning a device that truly integrates an electrical stimulation of a functional heart patch and self-powered e-care remote diagnostic sensor.


Subject(s)
Myocardial Infarction , Animals , Myocardial Infarction/therapy , Myocardial Infarction/physiopathology , Rats , Myocardium/metabolism , Myocardium/pathology , Male , Rats, Sprague-Dawley , Electric Stimulation , Humans , Myocardial Contraction
15.
J Nanobiotechnology ; 22(1): 258, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755644

ABSTRACT

Electrical stimulation (ES) is considered a promising therapy for chronic wounds via conductive dressing. However, the lack of a clinically suitable conductive dressing is a serious challenge. In this study, a suitable conductive biomaterial with favorable biocompatibility and conductivity was screened by means of an inherent structure derived from the body based on electrical conduction in vivo. Ions condensed around the surface of the microtubules (MTs) derived from the cell's cytoskeleton are allowed to flow in the presence of potential differences, effectively forming a network of biological electrical wires, which is essential to the bioelectrical communication of cells. We hypothesized that MT dressing could improve chronic wound healing via the conductivity of MTs applied by ES. We first developed an MT-MAA hydrogel by a double cross-linking method using UV and calcium chloride to improve chronic wound healing by ES. In vitro studies showed good conductivity, mechanical properties, biocompatibility, and biodegradability of the MT-MAA hydrogel, as well as an elevated secretion of growth factors with enhanced cell proliferation and migration ability in response to ES. The in vivo experimental results from a full-thickness diabetic wound model revealed rapid wound closure within 7d in C57BL/6J mice, and the wound bed dressed by the MT-MAA hydrogel was shown to have promoted re-epithelization, enhanced angiogenesis, accelerated nerve growth, limited inflammation phases, and improved antibacterial effect under the ES treatment. These preclinical findings suggest that the MT-MAA hydrogel may be an ideal conductive dressing for chronic wound healing. Furthermore, biomaterials based on MTs may be also promising for treating other diseases.


Subject(s)
Electric Conductivity , Hydrogels , Mice, Inbred C57BL , Microtubules , Wound Healing , Animals , Wound Healing/drug effects , Hydrogels/chemistry , Hydrogels/pharmacology , Mice , Microtubules/metabolism , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Male , Humans , Electric Stimulation , Cell Proliferation/drug effects , Cell Movement/drug effects , Bandages
16.
J Neuroeng Rehabil ; 21(1): 79, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38750521

ABSTRACT

A large proportion of stroke survivors suffer from sensory loss, negatively impacting their independence, quality of life, and neurorehabilitation prognosis. Despite the high prevalence of somatosensory impairments, our understanding of somatosensory interventions such as sensory electrical stimulation (SES) in neurorehabilitation is limited. We aimed to study the effectiveness of SES combined with a sensory discrimination task in a well-controlled virtual environment in healthy participants, setting a foundation for its potential application in stroke rehabilitation. We employed electroencephalography (EEG) to gain a better understanding of the underlying neural mechanisms and dynamics associated with sensory training and SES. We conducted a single-session experiment with 26 healthy participants who explored a set of three visually identical virtual textures-haptically rendered by a robotic device and that differed in their spatial period-while physically guided by the robot to identify the odd texture. The experiment consisted of three phases: pre-intervention, intervention, and post-intervention. Half the participants received subthreshold whole-hand SES during the intervention, while the other half received sham stimulation. We evaluated changes in task performance-assessed by the probability of correct responses-before and after intervention and between groups. We also evaluated differences in the exploration behavior, e.g., scanning speed. EEG was employed to examine the effects of the intervention on brain activity, particularly in the alpha frequency band (8-13 Hz) associated with sensory processing. We found that participants in the SES group improved their task performance after intervention and their scanning speed during and after intervention, while the sham group did not improve their task performance. However, the differences in task performance improvements between groups only approached significance. Furthermore, we found that alpha power was sensitive to the effects of SES; participants in the stimulation group exhibited enhanced brain signals associated with improved touch sensitivity likely due to the effects of SES on the central nervous system, while the increase in alpha power for the sham group was less pronounced. Our findings suggest that SES enhances texture discrimination after training and has a positive effect on sensory-related brain areas. Further research involving brain-injured patients is needed to confirm the potential benefit of our solution in neurorehabilitation.


Subject(s)
Electroencephalography , Humans , Male , Female , Adult , Touch Perception/physiology , Neurological Rehabilitation/methods , Electric Stimulation/methods , Young Adult , Touch/physiology , Stroke Rehabilitation/methods
17.
Sci Robot ; 9(90): eado9987, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38776376

ABSTRACT

Improving the performance of closed-loop optogenetic nerve stimulation can reproduce desired muscle activation patterns.


Subject(s)
Muscle, Skeletal , Optogenetics , Humans , Muscle, Skeletal/physiology , Paralysis , Animals , Electric Stimulation , Light , Muscle Contraction/physiology , Robotics/instrumentation , Equipment Design
18.
Sci Robot ; 9(90): eadi8995, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38776378

ABSTRACT

Closed-loop neuroprostheses show promise in restoring motion in individuals with neurological conditions. However, conventional activation strategies based on functional electrical stimulation (FES) fail to accurately modulate muscle force and exhibit rapid fatigue because of their unphysiological recruitment mechanism. Here, we present a closed-loop control framework that leverages physiological force modulation under functional optogenetic stimulation (FOS) to enable high-fidelity muscle control for extended periods of time (>60 minutes) in vivo. We first uncovered the force modulation characteristic of FOS, showing more physiological recruitment and significantly higher modulation ranges (>320%) compared with FES. Second, we developed a neuromuscular model that accurately describes the highly nonlinear dynamics of optogenetically stimulated muscle. Third, on the basis of the optogenetic model, we demonstrated real-time control of muscle force with improved performance and fatigue resistance compared with FES. This work lays the foundation for fatigue-resistant neuroprostheses and optogenetically controlled biohybrid robots with high-fidelity force modulation.


Subject(s)
Muscle Fatigue , Muscle, Skeletal , Optogenetics , Optogenetics/methods , Optogenetics/instrumentation , Animals , Muscle Fatigue/physiology , Muscle, Skeletal/physiology , Humans , Electric Stimulation/instrumentation , Muscle Contraction/physiology , Robotics/instrumentation , Male , Equipment Design , Neural Prostheses , Nonlinear Dynamics
19.
J Vis Exp ; (207)2024 May 03.
Article in English | MEDLINE | ID: mdl-38767361

ABSTRACT

Schwann cells (SCs) are myelinating cells of the peripheral nervous system, playing a crucial role in peripheral nerve regeneration. Nanosecond Pulse Electric Field (nsPEF) is an emerging method applicable in nerve electrical stimulation that has been demonstrated to be effective in stimulating cell proliferation and other biological processes. Aiming to assess whether SCs undergo significant changes under nsPEF and help explore the potential for new peripheral nerve regeneration methods, cultured RSC96 cells were subjected to nsPEF stimulation at 5 kV and 10 kV, followed by continued cultivation for 3-4 days. Subsequently, some relevant factors expressed by SCs were assessed to demonstrate the successful stimulation, including the specific marker protein, neurotrophic factor, transcription factor, and myelination regulator. The representative results showed that nsPEF significantly enhanced the proliferation and migration of SCs and the ability to synthesize relevant factors that contribute positively to the regeneration of peripheral nerves. Simultaneously, lower expression of GFAP indicated the benign prognosis of peripheral nerve injuries. All these outcomes show that nsPEF has great potential as an efficient treatment method for peripheral nerve injuries by stimulating SCs.


Subject(s)
Nerve Regeneration , Schwann Cells , Schwann Cells/cytology , Schwann Cells/physiology , Nerve Regeneration/physiology , Animals , Rats , Peripheral Nerves/physiology , Peripheral Nerves/cytology , Cell Proliferation/physiology , Electric Stimulation/methods , Peripheral Nerve Injuries/therapy
20.
Hear Res ; 447: 109027, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38723386

ABSTRACT

Despite that fact that the cochlear implant (CI) is one of the most successful neuro-prosthetic devices which allows hearing restoration, several aspects still need to be improved. Interactions between stimulating electrodes through current spread occurring within the cochlea drastically limit the number of discriminable frequency channels and thus can ultimately result in poor speech perception. One potential solution relies on the use of new pulse shapes, such as asymmetric pulses, which can potentially reduce the current spread within the cochlea. The present study characterized the impact of changing electrical pulse shapes from the standard biphasic symmetric to the asymmetrical shape by quantifying the evoked firing rate and the spatial activation in the guinea pig primary auditory cortex (A1). At a fixed charge, the firing rate and the spatial activation in A1 decreased by 15 to 25 % when asymmetric pulses were used to activate the auditory nerve fibers, suggesting a potential reduction of the spread of excitation inside the cochlea. A strong "polarity-order" effect was found as the reduction was more pronounced when the first phase of the pulse was cathodic with high amplitude. These results suggest that the use of asymmetrical pulse shapes in clinical settings can potentially reduce the channel interactions in CI users.


Subject(s)
Auditory Cortex , Cochlear Implants , Electric Stimulation , Animals , Guinea Pigs , Auditory Cortex/physiology , Evoked Potentials, Auditory , Cochlear Nerve/physiopathology , Acoustic Stimulation , Cochlea/surgery , Cochlear Implantation/instrumentation , Action Potentials , Female