1.
Braz J Med Biol Res ; 30(8): 1009-16, 1997 Aug.
Article in English | MEDLINE | ID: mdl-9361732

ABSTRACT

We describe a low-cost, high quality device capable of monitoring indirect activity by detecting touch-release events on a conducting surface, i.e., the animal's cage cover. In addition to the detecting sensor itself, the system includes an IBM PC interface for prompt data storage. The hardware/software design, while serving for other purposes, is used to record the circadian activity rhythm pattern of rats with time in an automated computerized fashion using minimal cost computer equipment (IBM PC XT). Once the sensor detects a touch-release action of the rat in the upper portion of the cage, the interface sends a command to the PC which records the time (hours-minutes-seconds) when the activity occurred. As a result, the computer builds up several files (one per detector/sensor) containing a time list of all recorded events. Data can be visualized in terms of actograms, indicating the number of detections per hour, and analyzed by mathematical tools such as Fast Fourier Transform (FFT) or cosinor. In order to demonstrate method validation, an experiment was conducted on 8 Wistar rats under 12/12-h light/dark cycle conditions (lights on at 7:00 a.m.). Results show a biological validation of the method since it detected the presence of circadian activity rhythm patterns in the behavior of the rats.


Subject(s)
Circadian Rhythm , Electronic Data Processing/economics , Animals , Computers , Rats , Rats, Wistar , Software
2.
Rev. bras. pesqui. méd. biol ; Braz. j. med. biol. res;30(8): 1009-16, Aug. 1997. ilus, tab
Article in English | LILACS | ID: lil-197259

ABSTRACT

We describe a low-cost, high quality device capable of monitoring indirect activity by detecting touch-release events on a conducting surface, i.e., the animal's cage cover. In addition to the detecting sensor itself, the system includes an IBM PC interface for prompt data storage. The hardware/software design, while serving for other purposes, is used to record the circadian activity rhythm pattern of rats with time in an automated computerized fashion using minimal cost computer equipment (IBM PC XT). Once the sensor detects a touch-release action of the rat in the upper portion of the cage, the interface sends a command to the PC which records the time (hours-minutes-seconds) when the activity occured. As a result, the computer builds up several files (one per detector/sensor) containing a time list of all recorded events. Data can be visualized in terms of actograms, indicating the number of detections per hour, and analyzed by mathematical tools such as Fast Fourier Transform (FFT) or cosinor. In order to demonstrate method validation, an experiment was conducted on 8 Wistar rats under 12/12-h ligh/dark cycle conditions (lights on at 7:00 a.m.). Results show a biological validation of the method since it detected the presence of circadian activity rhythm patterns in the behavior of the rats.


Subject(s)
Rats , Animals , Electronic Data Processing/economics , Circadian Rhythm , Computers , Rats, Wistar , Software