1.
Nat Commun ; 15(1): 7680, 2024 Sep 03.
Article in English | MEDLINE | ID: mdl-39227604

ABSTRACT

Intraluminal epithelial abnormalities, potential precursors to significant conditions like cancer, necessitate early detection for improved prognosis. We present a motor-free telerobotic optical coherence tomography (OCT) endoscope that offers high-resolution intraluminal imaging and overcomes the limitations of traditional systems in navigating curved lumens. This system incorporates a compact magnetic rotor with a rotatable diametrically magnetized cylinder permanent magnet (RDPM) and a reflector, effectively mitigating thermal and electrical risks by utilizing an external magnetic field to maintain temperature increases below 0.5 °C and generated voltage under 0.02 mV. Additionally, a learning-based method corrects imaging distortions resulting from nonuniform rotational speeds. Demonstrating superior maneuverability, the device achieves steerable angles up to 110° and operates effectively in vivo, providing distortion-free 3D programmable imaging in mouse colons. This advancement represents a significant step towards guidewire-independent endomicroscopy, enhancing both safety and potential patient outcomes.


Subject(s)
Tomography, Optical Coherence , Animals , Tomography, Optical Coherence/methods , Tomography, Optical Coherence/instrumentation , Mice , Imaging, Three-Dimensional/methods , Imaging, Three-Dimensional/instrumentation , Endoscopes , Humans , Equipment Design , Microscopy/methods , Microscopy/instrumentation , Endoscopy/methods , Endoscopy/instrumentation
3.
Comput Assist Surg (Abingdon) ; 29(1): 2404695, 2024 Dec.
Article in English | MEDLINE | ID: mdl-39305496

ABSTRACT

A robotic system for manipulating a flexible endoscope in surgery can provide enhanced accuracy and usability compared to manual operation. However, previous studies require large-scale, complex hardware systems to implement the rotational and translational motions of the soft endoscope cable. The conventional control of the endoscope by actuating the endoscope handle also leads to undesired slack between the endoscope tip and the handle, which becomes more problematic with long endoscopes such as a colonoscope. This study proposes a compact quad-roller friction mechanism that enables rotational and translational motions triggered not from the endoscope handle but at the endoscope tip. Controlling two pairs of tilted rollers achieves both types of motion within a small space. The proposed system also introduces an unsynchronized motion strategy between the handle and tip parts to minimize the robot's motion near the patient by employing the slack positively as a control index. Experiments indicate that the proposed system achieves accurate rotational and translational motions, and the unsynchronized control method reduces the total translational motion by up to 88% compared to the previous method.


Subject(s)
Endoscopes , Equipment Design , Friction , Robotic Surgical Procedures , Humans , Robotic Surgical Procedures/instrumentation , Robotic Surgical Procedures/methods , Robotics/instrumentation
4.
World J Gastroenterol ; 30(31): 3680-3688, 2024 Aug 21.
Article in English | MEDLINE | ID: mdl-39192996

ABSTRACT

BACKGROUND: Commonly used cleaning brushes in the reprocessing of flexible endoscopes often cause damage within the working channels. AIM: To develop a spray flushing system to achieving effective cleaning of the working channels while minimizing damage. METHODS: This prospective study included 60 used endoscopes and 60 Teflon tubes randomly divided into a control group (n = 30) and an experimental group (n = 30). The material of Teflon tubes was the same as that of the endoscope working channel. Endoscopes in the control group were manually cleaned using traditional cleaning brushes, while those in the experimental group were cleaned using the newly developed spray flushing system. ATP levels, cleanliness, and microbiological testing of the working channels were measured. Additionally, Teflon tubes in the control group underwent 500 passes with a cleaning brush, while those in the experimental group were subjected to the spray flushing system, and channel damage was evaluated. RESULTS: The ATP levels (RLU) in the two groups were 32.5 (13-66) and 26 (16-40), respectively (P > 0.05). Cleanliness scores were 1.5 (1-2) and 1 (1-2), respectively (P > 0.05). Debris was found in 73.3% of the control group, which was significantly higher than 46.7% in the experimental group (P < 0.05). Microbiological tests for both groups yielded negative results. Teflon tube damage in the control group was rated at 4 (4-5.25), which was significantly higher than in the experimental group 4 (3-4) (P < 0.01). CONCLUSION: The spray flushing system demonstrated superior efficacy in removing debris and resulted in less damage to the endoscope working channels compared with traditional cleaning brushes.


Subject(s)
Adenosine Triphosphate , Disinfection , Endoscopes , Equipment Contamination , Prospective Studies , Disinfection/methods , Equipment Contamination/prevention & control , Humans , Adenosine Triphosphate/analysis , Adenosine Triphosphate/metabolism , Endoscopes/microbiology , Equipment Reuse/standards , Polytetrafluoroethylene , Endoscopes, Gastrointestinal/microbiology , Equipment Design , Cross Infection/prevention & control
5.
Comput Methods Programs Biomed ; 256: 108380, 2024 Nov.
Article in English | MEDLINE | ID: mdl-39178502

ABSTRACT

BACKGROUND AND OBJECTIVES: In endoscopy, measurement of target size can assist medical diagnosis. However, limited operating space, low image quality, and irregular target shape pose great challenges to traditional vision-based measurement methods. METHODS: In this paper, we propose a novel approach to measure irregular target size under monocular endoscope using image rendering. Firstly synthesize virtual poses on the same main optical axis as known camera poses, and use implicit neural representation module that considers brightness and target boundaries to render images corresponding to virtual poses. Then, Swin-Unet and rotating calipers are utilized to obtain maximum pixel length of the target in image pairs with the same main optical axis. Finally, the similarity triangle relationship of the endoscopic imaging model is used to measure the size of the target. RESULTS: The evaluation is conducted using renal stone fragments of patients which are placed in the kidney model and the isolated porcine kidney. The mean error of measurement is 0.12 mm. CONCLUSIONS: The approached method can automatically measure object size within narrow body cavities in any visible direction. It improves the effectiveness and accuracy of measurement in limited endoscopic space.


Subject(s)
Endoscopes , Swine , Humans , Animals , Algorithms , Endoscopy/methods , Image Processing, Computer-Assisted/methods , Kidney/diagnostic imaging , Kidney/physiology , Kidney/anatomy & histology , Imaging, Three-Dimensional/methods
6.
Article in Chinese | MEDLINE | ID: mdl-39193748

ABSTRACT

Objective:To investigate the clinical effect of retroauricular hairline approach in submandibular gland resection assisted by endoscope. Methods:A total of 18 patients with submandibular gland benign tumors treated in our hospital from September 2022 to September 2023 were selected. A 5 cm incision was designed in the retroauricular hairline, and the flap was turned over directly to the anterior edge of sternocleidomastoid muscle, then the flap was turned over to build the cavity through endoscopic surgery, and submandibular gland resection was completed with the assistance of endoscope. After operation, a negative pressure drainage was placed into the hairline, and the wound was closed by continuous intracutaneous suture. The clinical effect was evaluated after 3-6 months follow-up. Results:All patients underwent submandibular gland resection with endoscopic assistance as planned, and none of them converted to submaxillary incision during operation. The operation time was 65-97 min, with an average of 75 min. Intraoperative bleeding was 10-20 mL, with an average of 14 mL.No tongue numbness, wound infection, or tumor recurrence occurred after operation. However, there were 10 patients with ear numbness and discomfort of auricle after surgery, which gradually recovered after 6-9 months of follow-up. Two patients had crooked mouth after surgery, and the symptoms were gradually relieved after follow-up. All incisions healed in stage I and were concealed. Conclusion:Endoscopic retroauricular hairline approach is a choice for submandibular gland resection with good cosmetic effect, less trauma and fewer complications.


Subject(s)
Endoscopy , Submandibular Gland , Humans , Male , Female , Endoscopy/methods , Submandibular Gland/surgery , Adult , Middle Aged , Surgical Flaps , Submandibular Gland Neoplasms/surgery , Endoscopes , Treatment Outcome , Operative Time
7.
Int J Clin Oncol ; 29(10): 1399-1406, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38976183

ABSTRACT

Nerves and blood vessels must be protected during brain tumor surgery, which has traditionally relied on microscopes. In the 2000s, endoscopes and related equipment were developed for neurosurgery. In this review, we aim to outline the role of endoscopes in brain tumor surgery and discuss the emerging use of exoscopes. The primary use of endoscopes in brain tumor surgery is in endoscopic endonasal surgery for pituitary tumors. By using the space within the sphenoid sinus, surgeons can insert an endoscope and instruments such as forceps or scissors through the nose to access and remove the tumor. Compared to microscopes, endoscopes can get closer to tumors, nerves, and blood vessels. They enable wide-angle observation of the skull base, making them valuable for skull base tumors as well as pituitary tumors. Endoscopes are also used in cases where a brain tumor is associated with hydrocephalus, allowing surgeons to correct obstructive hydrocephalus and perform tumor biopsies simultaneously. Exoscopy, a newer technique introduced in recent years, involves surgeons wearing special glasses and removing the tumor while viewing a three-dimensional monitor. This approach reduces surgeon fatigue and allows for more natural positioning during lengthy brain tumor surgeries. Future brain tumor surgeries will likely involve robotic surgery, which is already used for other organs. This is expected to make brain tumor removal safer and more accurate.


Subject(s)
Brain Neoplasms , Humans , Brain Neoplasms/surgery , Endoscopy/methods , Neurosurgical Procedures/methods , Robotic Surgical Procedures/methods , Pituitary Neoplasms/surgery , Pituitary Neoplasms/pathology , Endoscopes
8.
Article in Chinese | MEDLINE | ID: mdl-38973048

ABSTRACT

Objective:To investigate the therapeutic effect of ß-tricalcium phosphate in mastoid cavity obliteration for middle ear cholesteatoma under endoscope. Methods:Sixty patients with middle ear cholesteatoma admitted to our department from September 2021 to March 2022 were included in this study. The observation group(n=30) received ß-tricalcium phosphate during mastoid cavity obliteration. The control group(n=30) received autologous tissue during mastoid cavity obliteration. Pure tone audiometry was performed before surgery and after surgery in both groups, and the air conduction thresholds of 500, 1 000, 2 000 and 4 000 Hz were recorded. The external acoustic meatus cross-sectional area within 1 cm of the external acoustic meatus opening was measured during the operation and after the operation. The differences of postoperative ear drying time, hearing change and mastoid cavity healing were compared between the two groups. Results:The duration of postoperative dry ear in the observation group was 2-14 weeks, with an average of (9.4±2.7) weeks, while that in the control group was 4-26 weeks, with an average of(16.0±5.7) weeks. The difference in dry ear time between the two groups was statistically significant(P<0.05). In the observation group, the threshold change was -19-27 dB, with an average of(6.4±10.7) dB, and in the control group, the threshold change was -9-17 dB, with an average of (4.7±7.1) dB. There was no significant difference in hearing change between the two groups(P>0.05). In the observation group, the cross-sectional area of 1 cm inside the ear canal opening was -5.9-8.2 mm², with an average of (-0.6±2.6) mm², and in the control group, the cross-sectional area of 1 cm inside the ear canal opening was -5.5-5.2 mm², with an average of (-0.4±2.3) mm². There was no significant difference in intraoperative cavity changes between the two groups(P>0.05). Conclusion:The application of ß-tricalcium phosphate to fill the mastoid cavity during the operation of endoscopic middle ear cholesteatoma has no adverse effect on the hearing of patients, can shorten the postoperative dry ear time, and results in good postoperative healing, which is worth promoting.


Subject(s)
Calcium Phosphates , Cholesteatoma, Middle Ear , Mastoid , Humans , Calcium Phosphates/therapeutic use , Mastoid/surgery , Cholesteatoma, Middle Ear/surgery , Male , Female , Adult , Endoscopy/methods , Middle Aged , Audiometry, Pure-Tone , Treatment Outcome , Endoscopes
9.
Article in English | MEDLINE | ID: mdl-39017782

ABSTRACT

This chapter is intended to provide a brief overview of the optics of surgical microscopes and rigid endoscopes, with the aim of providing the reader with the principles dictating the nature of surgical visualization when either of the visual control systems is used. It is not by any means geared toward elaborating on the detailed optical physics of these systems, which is beyond the scope and objective of this chapter.


Subject(s)
Microscopy , Humans , Microscopy/instrumentation , Microscopy/methods , Neurosurgical Procedures/instrumentation , Neurosurgical Procedures/methods , Microsurgery/instrumentation , Microsurgery/methods , Endoscopes , Neuroendoscopes
10.
J Zhejiang Univ Sci B ; 25(7): 628-632, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39011682

ABSTRACT

Airborne transmission is among the most frequent types of nosocomial infection. Recent years have witnessed frequent outbreaks of airborne diseases, such as severe acute respiratory syndrome (SARS) in 2002, Middle East respiratory syndrome (MERS) in 2012, and coronavirus disease 2019 (COVID-19), with the latter being on the rampage since the end of 2019 and bringing the effect of aerosols on health back to the fore (Gralton et al., 2011; Wang et al., 2021). An increasing number of studies have shown that certain highly transmissible pathogens can maintain long-term stability and efficiently spread through aerosols (Leung, 2021; Lv et al., 2021). As reported previously, influenza viruses that can spread efficiently through aerosols remain stable for a longer period compared to those that cannot. The World Health Organization (WHO) has stated that aerosol-generating procedures (AGPs) play an important role in aerosol transmission in hospitals (Calderwood et al., 2021). AGPs, referring to medical procedures that produce aerosols, including dental procedures, endotracheal intubation, sputum aspiration, and laparoscopic surgeries, have been reported to be significantly associated with an increased risk of nosocomial infection among medical personnel (Hamilton, 2021).


Subject(s)
Aerosols , COVID-19 , Cross Infection , Endoscopes , SARS-CoV-2 , Humans , Cross Infection/transmission , Cross Infection/prevention & control , COVID-19/transmission , SARS-CoV-2/isolation & purification , Pandemics , Coronavirus Infections/transmission , Pneumonia, Viral/transmission , Disinfection/methods , Betacoronavirus , Air Microbiology
11.
Neurol Med Chir (Tokyo) ; 64(7): 283-288, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38839298

ABSTRACT

The indication for surgical intervention in spontaneous intracerebral hemorrhage remains controversial. Although many clinical trials have failed to demonstrate its efficacy over medical treatment, less invasive endoscopic treatment is expected to demonstrate its superiority. A novel endoscopic system for hematoma removal consisting of a 3.1-mm-diameter 4K high-resolution rigid endoscope was used.The system was used in eight cases of spontaneous intracerebral hemorrhage. It provided improved maneuverability of the surgical instrument while maintaining satisfactory image quality. The surgical goal was achieved in all cases without any complications, including perioperative rebleeding.Endoscopic hematoma removal using the 3.1 mm high-resolution endoscope is an alternative minimally invasive approach to spontaneous intracerebral hemorrhage with improved reliability.


Subject(s)
Cerebral Hemorrhage , Hematoma , Neuroendoscopy , Humans , Cerebral Hemorrhage/surgery , Cerebral Hemorrhage/diagnostic imaging , Aged , Male , Middle Aged , Female , Hematoma/surgery , Hematoma/diagnostic imaging , Neuroendoscopy/methods , Neuroendoscopy/instrumentation , Aged, 80 and over , Endoscopes , Equipment Design
12.
IEEE J Transl Eng Health Med ; 12: 499-507, 2024.
Article in English | MEDLINE | ID: mdl-38899143

ABSTRACT

OBJECTIVE: Variable-view rigid scopes offer advantages compared to traditional angled laparoscopes for examining a diagnostic site. However, altering the scope's view requires a high level of dexterity and understanding of spatial orientation. This requires an intuitive mechanism to allow an operator to easily understand the anatomical surroundings and smoothly adjust the scope's focus during diagnosis. To address this challenge, the objective of this work is to develop a mechanized arm that assists in visualization using variable-view rigid scopes during diagnostic procedures. METHODS: A system with a mechanized arm to maneuver a variable-view rigid scope (EndoCAMeleon - Karl Storz) was developed. A user study was conducted to assess the ability of the proposed mechanized arm for diagnosis in a preclinical navigation task and a simulated cystoscopy procedure. RESULTS: The mechanized arm performed significantly better than direct maneuvering of the rigid scope. In the preclinical navigation task, it reduced the percentage of time the scope's focus shifted outside a predefined track. Similarly, for simulated cystoscopy procedure, it reduced the duration and the perceived workload. CONCLUSION: The proposed mechanized arm enhances the operator's ability to accurately maneuver a variable-view rigid scope and reduces the effort in performing diagnostic procedures.Clinical and Translational Impact Statement: The preclinical research introduces a mechanized arm to intuitively maneuver a variable-view rigid scope during diagnostic procedures, while minimizing the mental and physical workload to the operator.


Subject(s)
Equipment Design , Humans , Cystoscopy/methods , Cystoscopy/instrumentation , Endoscopes
13.
Clin Nurse Spec ; 38(4): 189-192, 2024.
Article in English | MEDLINE | ID: mdl-38889060

ABSTRACT

PURPOSE/OBJECTIVES: The Centers for Disease Control and Prevention has highlighted the strong association between healthcare-associated infections and the reprocessing of flexible endoscopes. This process improvement project provided an evidence-based workflow analysis of pleuravideoscope reprocessing to validate and implement safe practices in the pulmonary clinic and sterile processing department. DESCRIPTION OF THE PROJECT/PROGRAM: A multidisciplinary team created an audit tool to complete infection control risk assessment using Lean Six Sigma methodology. OUTCOME: The risk assessment identified gaps in clinical practice, prompting corrective measures using a shared decision-making approach. The organization updated standard operating procedures, provided training and competency assessments, and purchased single-use pleuravideoscopes. These initiatives addressed the deficiencies and reinforced a culture of continuous process improvement and patient safety. CONCLUSION: Multidisciplinary teams should perform comprehensive reviews of facility processes and assess the risks related to infection control to identify optimal pleuravideoscope workflows for the healthcare institution. The involvement of a clinical nurse specialist is advantageous, as they possess the expertise necessary to facilitate collaborative efforts among team members spanning various departments. By leveraging the insights and skills of diverse professionals, healthcare organizations can optimize their reprocessing programs and enhance patient safety.


Subject(s)
Sterilization , Humans , Nurse Clinicians , Endoscopes/microbiology , Patient Care Team/organization & administration , Cross Infection/prevention & control , Infection Control , Equipment Contamination/prevention & control , Nursing Evaluation Research
14.
J Robot Surg ; 18(1): 266, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38916651

ABSTRACT

The endoscopic control system has remained similar in design for many decades The remit of advanced therapeutic endoscopy continues to expand requiring precision control and high cognitive workloads. Robotic systems are emerging, but all still require bimanual control and expensive and large new systems. Eye tracking is an exciting area that can be used as an endoscope control system. This is a study to establish the feasibility of an eye-controlled endoscope and compare its performance and cognitive demand to use of a conventional endoscope. An eye gaze-control system consisting of eye-tracking glasses, customised software and a small motor unit was built and attached to a conventional endoscope. Twelve non-endoscopists used both the eye gaze system and a conventional endoscope to complete a benchtop task in a simulated oesophagus and stomach. Completion of tasks was timed. Subjective feedback was collected from each participant on task load using the NASA Task Load Index. Participants were significantly quicker completing the task using iGAZE2 vs a conventional endoscope (65.02 ± 16.34s vs 104.21 ± 51.31s, p = 0.013) Participants were also significantly quicker completing retroflexion using iGAZE2 vs a conventional endoscope (8.48 ± 3.08 vs 11.38 ± 5.36s, p = 0.036). Participants reported a significantly lower workload (raw NASA-TLX score) when using iGAZE2 vs the conventional endoscope (152.1 ± 63.4 vs 319.6 ± 81.6, p = 0.0001) (Fig. 7). Users found iGAZE2 to have a significantly lower temporal demand, mental demand, effort, mental demand, physical demand, and frustration level. The eye gaze system is an exciting, small, and retrofittable system to any endoscope. The system shows exciting potential as a novel endoscopic control system with a significantly lower workload and better performance in novices suggesting a more intuitive control system.


Subject(s)
Eye-Tracking Technology , Robotic Surgical Procedures , Humans , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Male , Equipment Design , Female , Adult , Task Performance and Analysis , Feasibility Studies , Endoscopy/methods , Endoscopes
15.
J Hosp Infect ; 150: 91-95, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38830542

ABSTRACT

INTRODUCTION: Biofilm contributes significantly to bacterial persistence in endoscope channels. Enhanced cleaning methods capable of removing biofilm from all endoscope channels are required to decrease infection risk to patients. This head-to-head study compared cyclic build-up biofilm removal of an automated endoscope channel cleaner (AECC) with standard manual cleaning according to instructions for use (IFU) in polytetrafluorethylene channels. METHODS: Cyclic build-up biofilm was grown in 1.4-mm (representing air/water and auxiliary channels) and 3.7-mm (representing suction/ biopsy channels) inner diameter polytetrafluorethylene channels. All channels were tested for residual total organic carbon, protein, and viable bacteria. Internationally recognized ISO 15883-5:2021 alert levels were used as cleaning benchmarks for protein (3 µg/cm2) and total organic carbon (6 µg/cm2). RESULTS: The automated cleaner significantly outperformed manual cleaning for all markers assessed (protein, total organic carbon, viable bacteria) in 1.4-mm and 3.7-mm channels representing air/water/auxiliary and suction/biopsy channels, respectively. Manual cleaning failed to remove biofilm from the air/water and auxiliary channels. According to the IFU, these channels are not brushed, suggesting a potential root cause for a portion of the numerous endoscopy-associated infections reported in the literature. CONCLUSION: AECC shows potential to deliver enhanced cleaning over current practice to all endoscope channels and may thereby address infection risk.


Subject(s)
Biofilms , Endoscopes , Biofilms/growth & development , Endoscopes/microbiology , Disinfection/methods , Decontamination/methods , Humans , Equipment Contamination/prevention & control , Bacteria/isolation & purification
17.
Neurocirugia (Astur : Engl Ed) ; 35(4): 221-224, 2024.
Article in English | MEDLINE | ID: mdl-38801859

ABSTRACT

The superior canal dehiscence syndrome is a pathology that affects the arcuate eminence creating a "third window" between the inner ear and the middle fossa. This condition can lead to symptoms such as hearing loss, autophony, or sound-induced vertigo. Traditionally, surgical treatment has been performed by microscope-assisted temporal craniotomy, but when the dehiscence is in the medial part of the arcuate eminence the bone defect may not be seen. We present case series treated at our institution diagnosed of superior canal dehiscence syndrome involving the medial slope of the arcuate eminence. During surgery, the bone defect could not be visible with traditional microscopic techniques. Nonetheless, by introducing the endoscope with the 0º and 30º optics, the dehiscence could be clearly observed and treated correctly. Our results show a clinical improvement without side effects or complications in the patients undergoing this technique. Endoscope-assisted surgery is a safe procedure and provides a better visualization of medial defects.


Subject(s)
Semicircular Canal Dehiscence , Humans , Male , Female , Middle Aged , Semicircular Canal Dehiscence/surgery , Aged , Adult , Endoscopy/methods , Semicircular Canals/surgery , Endoscopes , Craniotomy/methods
18.
Rev Gastroenterol Mex (Engl Ed) ; 89(3): 332-339, 2024.
Article in English | MEDLINE | ID: mdl-38644085

ABSTRACT

INTRODUCTION AND AIMS: Adequate drying and proper storage of flexible endoscopes are essential for maintaining quality in their reprocessing. The aim of the present study was to evaluate the drying stages, storage, and channel conditions of endoscopes through borescope inspection. MATERIAL AND METHODS: The personnel responsible for endoscope reprocessing were interviewed. Storage conditions at 10 endoscopy facilities were inspected and an internal examination of the channels and ports of the stored equipment was carried out, utilizing a borescope. A total of 74 stored endoscope channels were evaluated. RESULTS: Only 10% of the facilities inspected utilized transport cases for storage and only 10% had rooms exclusively used for storage. Sixty percent of the facilities did not perform any shelf-life control. All the channels evaluated were scratched and fluids were present on 69% of them. CONCLUSIONS: Endoscope reprocessing can be improved through the implementation of drying and storage control and validation tools, as well as the use of borescopes and periodic clinical audits.


Subject(s)
Endoscopes , Equipment Reuse , Humans , Endoscopes/standards , Equipment Reuse/standards , Equipment Contamination/prevention & control , Disinfection/methods , Disinfection/standards , Desiccation
19.
J Hosp Infect ; 149: 36-45, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38649121

ABSTRACT

BACKGROUND: Contamination rates reported in the literature for patient-ready flexible endoscopes vary from 0.4% to 49%. Unfortunately, the comparison and interpretation of these results is almost impossible since several factors including sampling and culturing methods, target levels for contamination, or definition of indicator micro-organisms vary widely from one study to the other. AIM: To compare the efficacy of six duodenoscope sampling and culturing methods by means of extraction efficacy comparison, while at the same time identifying key parameters that provide optimal microbial recovery. METHODS: The duodenoscope sample extraction efficacy of each method was assessed using the repetitive recovery method described in ISO 11737-1: 2018. FINDINGS: Mean overall bioburden extraction efficacy varied from 1% for the Australian method to 39% for the French one. The lowest endoscope sample extraction efficacy was associated with the absence of any neutralizer, friction, or tensioactive agent, and when only a small portion of the sampling solution collected was inoculated on to culture media. The efficacy of the sampling and culturing methods also varied according to the nature of micro-organisms present in the endoscope, and the time between sampling and culturing. CONCLUSION: This study supports the need for a harmonized and standardized sampling and culturing method for flexible endoscopes.


Subject(s)
Equipment Contamination , Specimen Handling , Humans , Specimen Handling/methods , Specimen Handling/instrumentation , Equipment Contamination/prevention & control , Bacteria/isolation & purification , Bacteria/classification , Microbiological Techniques/methods , Endoscopes/microbiology , Duodenoscopes/microbiology
20.
Acta Med Indones ; 56(1): 84-92, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38561887

ABSTRACT

Corrosive injuries (CI) become medical problems related complications include esophageal, pyloric stricture and squamous cell carcinoma, physical and quality of life. Endoscopic (ED) dilatation is primary therapy. The ultrathin endoscope-assisted method is potentially safe and useful in avoiding technical failure. Describe clinical outcomes of ED ED-related CI including successful, refractory, recurrent, and complications-related procedures. Case series study of esophageal and/or pyloric stricture patients after CI who underwent dilatation at Soetomo General Hospital (July 2018 - July 2022). One - biweekly ED using Through The Scope (TTS) balloon or Savary Bougie dilator. The target diameter is 14mm. Fifteen patients with stricture-related CI. Eleven patients underwent ED with a total of 73 procedures. Mean age 31,45 years, predominantly male patients (6), suicide attempt (7), acid agent (9), located at esophagus (3), pylorus (3), or both (5). Number of esophageal dilatation to achieve the target of 14 mm was 1-2 and 2-15 procedures for simple and complex stricture. Five esophageal strictures were successfully dilated but 2 patients were recurrent and 3 cases were refractory to ED. Pyloric dilatation resulted in a lower success rate. Recurrent and refractory cases were 5 and 3 patients respectively. ED with ultrathin endoscope method is useful for traversing guidewire during ED. Ongoing inflammation and fibrosis were linked to recurrent and refractory stricture.


Subject(s)
Burns, Chemical , Caustics , Esophageal Stenosis , Humans , Male , Female , Caustics/toxicity , Constriction, Pathologic , Esophagoscopy/adverse effects , Esophagoscopy/methods , Dilatation/adverse effects , Dilatation/methods , Quality of Life , Treatment Outcome , Esophageal Stenosis/chemically induced , Esophageal Stenosis/therapy , Esophageal Stenosis/complications , Endoscopes/adverse effects , Burns, Chemical/therapy , Burns, Chemical/complications
SELECTION OF CITATIONS