Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 6.929
Filter
1.
Int Angiol ; 43(2): 298-305, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38801345

ABSTRACT

BACKGROUND: Careful selection of patients for carotid stenting is necessary. We suggest that patients with a shaggy aorta syndrome may be at higher risk for perioperative embolic complications. METHODS: The study is a retrospective subanalysis of the SIBERIA Trial. We included 72 patients undergoing transfemoral carotid artery stenting. Patients were monitored during the procedures using multifrequency transcranial Doppler with embolus detection and differentiation. Pre- and postprocedural (2 and 30 days) cerebral diffusion-weighted cerebral MRIs were performed. RESULTS: Forty-six patients had shaggy aorta syndrome. Intraoperative embolisms were recorded in 82.6% and 46.1% of patients with and without shaggy aorta syndrome, respectively (P=0.001). New asymptomatic ischemic brain lesions in the postoperative period occurred in 78.3% and in 26.9% of patients with and without shaggy aorta syndrome, respectively (P<0.001). There were no cases of stroke within 2 days in both groups. 3 (6.5%) cases of stroke within 30 days after the procedure were observed only in patients with shaggy aorta syndrome. There were no cases of contralateral stroke. Shaggy aorta syndrome (OR 5.54 [1.83:16.7], P=0.001) and aortic arch ulceration (OR 6.67 [1.19: 37.3], P=0.02) were independently associated with cerebral embolism. Shaggy aorta syndrome (OR 9.77 [3.14-30.37], P<0.001) and aortic arch ulceration (OR 12.9 [2.3: 72.8], P=0.003) were independently associated with ipsilateral new asymptomatic ischemic brain lesions. CONCLUSIONS: Shaggy aorta syndrome and aortic arch ulceration significantly increase the odds of intraoperative embolism and new asymptomatic ischemic brain lesions. Carotid endarterectomy or transcervical carotid stent should be selected in patients with shaggy aorta syndrome.


Subject(s)
Intracranial Embolism , Stents , Humans , Intracranial Embolism/etiology , Intracranial Embolism/diagnostic imaging , Male , Female , Stents/adverse effects , Aged , Retrospective Studies , Middle Aged , Risk Factors , Aortic Diseases/diagnostic imaging , Aortic Diseases/complications , Diffusion Magnetic Resonance Imaging , Intraoperative Complications/epidemiology , Treatment Outcome , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/complications , Carotid Stenosis/surgery , Ultrasonography, Doppler, Transcranial , Syndrome , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Aged, 80 and over
4.
Neurosurg Clin N Am ; 35(3): 379-387, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38782531

ABSTRACT

Cerebrospinal fluid (CSF) bathing the central nervous system is produced by brain and choroid plexus within the ventricles for re-absorption into the venous circulation through arachnoid granulations (AG). Communicating hydrocephalus results from disruption of the absorptive process, necessitating surgical catheter-based shunt placement to relieve excess pressure from CSF buildup. Adjustable valve designs and antibiotic impregnation have minimally impacted persistent failure rates and postoperative complications. To confront this challenge, we have developed an innovative endovascular shunt implant biologically inspired from AG function to restore the natural dynamics of CSF drainage while concurrently addressing the predominant factors contributing to conventional shunt malfunction.


Subject(s)
Cerebrospinal Fluid Shunts , Hydrocephalus , Humans , Hydrocephalus/surgery , Cerebrospinal Fluid Shunts/adverse effects , Cerebrospinal Fluid Shunts/methods , Cerebrospinal Fluid Shunts/instrumentation , Endovascular Procedures/methods , Endovascular Procedures/instrumentation
5.
Sci Transl Med ; 16(747): eadl4497, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748771

ABSTRACT

Endovascular interventions are increasingly becoming the preferred approach for treating strokes and cerebral artery diseases. These procedures rely on sophisticated angiographical imaging guidance, which encounters challenges because of limited contrast and spatial resolution. Achieving a more precise visualization of the underlying arterial pathology and neurovascular implants is crucial for accurate procedural decision-making. In a human study involving 32 patients, we introduced the clinical application of a miniaturized endovascular neuro optical coherence tomography (nOCT) imaging probe. This technology was designed to navigate the tortuous paths of the cerebrovascular circulation and to offer high-resolution imaging in situ. The nOCT probe is compatible with standard neurovascular microcatheters, integrating with the procedural workflow used in clinical routine. Equipped with a miniaturized optical fiber and a distal lens, the probe illuminates the tissue and collects the backscattered, near-infrared light. While rotating the fiber and the lens at high speed, the probe is rapidly retracted, creating a spiral-shaped light pattern to comprehensively capture the arterial wall and implanted devices. Using nOCT, we demonstrated volumetric microscopy of cerebral arteries in patients undergoing endovascular procedures. We imaged the anterior and posterior circulation of the brain, including distal segments of the internal carotid and middle-cerebral arteries, as well as the vertebral, basilar, and posterior cerebral arteries. We captured a broad spectrum of neurovascular pathologies, such as brain aneurysms, ischemic stroke, arterial stenoses, dissections, and intracranial atherosclerotic disease. nOCT offered artifact-free, high-resolution visualizations of intracranial artery pathology and neurovascular devices.


Subject(s)
Cerebral Arteries , Tomography, Optical Coherence , Tomography, Optical Coherence/methods , Humans , Cerebral Arteries/diagnostic imaging , Microscopy/methods , Miniaturization , Endovascular Procedures/instrumentation , Endovascular Procedures/methods
6.
JACC Cardiovasc Interv ; 17(9): 1148-1159, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38749596

ABSTRACT

BACKGROUND: The effectiveness and safety of carotid artery stenting (CAS) are comparable to those of carotid endarterectomy in both symptomatic and asymptomatic patients with carotid artery stenosis, but real-world outcomes are not well-known. OBJECTIVES: The purpose of this study was to investigate the real-world clinical outcomes of CAS in symptomatic and asymptomatic patients with carotid artery stenosis. METHODS: We conducted a nationwide retrospective registry study of 156 centers between January 2015 and December 2019. We enrolled consecutive patients with CAS managed by certified specialists from the Japanese Society of Neuroendovascular Therapy. Outcomes between symptomatic and asymptomatic patients were compared. The primary outcome was a composite of ischemic stroke and all-cause death at 30 days after CAS. Secondary outcomes were ischemic stroke, all-cause death, intracranial hemorrhage (ICH), and procedural complications. RESULTS: We analyzed 9,792 patients (symptomatic, n = 5,351; asymptomatic, n = 4,441). The mean age was 73.5 years, and men were dominant (86.4%). Embolism protection devices were used in 99% of patients. The primary outcome was not significantly different between the symptomatic and asymptomatic groups (120 [2.2%] vs 65 [1.5%]; adjusted OR: 1.30; 95% CI: 0.92-1.83). The incidences of symptomatic ICH, any ICH, acute in-stent occlusion, and hyperperfusion syndrome were significantly more prevalent in the symptomatic group (47 [0.9%] vs 8 [0.2%], aOR: 4.41 [95% CI: 1.68-11.6]; 73 [1.4%] vs 12 [0.3%], aOR: 3.56 [95% CI: 1.71-7.39]; 45 [0.8%] vs 19 [0.4%], aOR: 2.18 [95% CI: 1.08-4.40]; and 102 [1.9%] vs 36 [0.8%], aOR: 1.78 [95% CI: 1.17-2.71], respectively). Other secondary outcomes were not significantly different between the 2 groups. CONCLUSIONS: The complication rate after specialist-involved CAS at 30 days was low in real-world practice.


Subject(s)
Asymptomatic Diseases , Carotid Stenosis , Endovascular Procedures , Registries , Stents , Humans , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/therapy , Carotid Stenosis/mortality , Carotid Stenosis/complications , Male , Female , Aged , Retrospective Studies , Treatment Outcome , Time Factors , Risk Factors , Japan , Aged, 80 and over , Risk Assessment , Middle Aged , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Ischemic Stroke/mortality , Ischemic Stroke/etiology , Intracranial Hemorrhages/etiology
11.
Neurol Res ; 46(6): 538-543, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38561007

ABSTRACT

BACKGROUND: Enterprise stent was approved for the treatment of wide-necked intracranial aneurysms. However, it has been widely used in the endovascular treatment of intracranial artery stenosis, which is still controversial. The purpose of this study was to evaluate the safety and efficiency of the Enterprise stent in the endovascular treatment of intracranial artery stenosis disease. METHODS: We conducted a retrospective case series of 107 patients with intracranial artery stenosis who received Enterprise stent implantation at Nanjing Drum Tower Hospital from January 2020 to December 2022. The rates of recanalization, perioperative complications, in-stent restenosis at 3-12 months and stroke recurrence were assessed for endovascular treatment. RESULTS: A total of 107 individuals were included in this study, 88 were followed up, and 19 (17.8%) patients were lost to follow-up. The operation success rate was 100%, During the procedure,4(3.7%)patients had vasospasm, and 2(1.9%) patients showed symptomatic bleeding. The overall perioperative complication rate was 5.6%, including 2.8% distal artery embolism, 0.9% in-stent thrombosis, and 1.9% symptomatic bleeding. 88 (82.2%) patients were followed up from 3 to 12 months, of whom 12 (13.6%) had in-stent restenosis, 4 (4.7%) recurrent strokes and 2 died of pulmonary infection caused by COVID-19. Patients were divided into 3 groups according to the cerebral artery, including the middle cerebral artery group, internal carotid artery group, and vertebrobasilar artery group. CONCLUSIONS: In this study, the placement of the Enterprise stent in patients with symptomatic non-acute intracranial stenosis was successful. However, the occurrence of periprocedural and long-term complications after stenting remains of high concern.


Subject(s)
Endovascular Procedures , Stents , Humans , Male , Female , Middle Aged , Stents/adverse effects , Retrospective Studies , Endovascular Procedures/methods , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Aged , Adult , Treatment Outcome , Constriction, Pathologic , Intracranial Arterial Diseases/surgery
12.
Eur J Radiol ; 175: 111446, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38581861

ABSTRACT

PURPOSE: To investigate the safety and efficacy of large-bore uncovered stents for treating malignant superior vena cava syndrome. METHODS: This retrospective study included 115 patients (89 men, 26 women; mean age 63.2 years; range 21-83 years) who underwent endovascular large-bore (≥18 mm in diameter) uncovered stent placement between August 2015 and July 2022. One patient was lost to follow-up. Therefore, 114 patients were available for follow-up. RESULTS: Stent placement was technically successful in all 115 patients. Minor procedure-related complications occurred in nine (7.8 %) patients. One hundred eight (93.9 %) patients experienced complete or marked symptomatic relief (Kishi score ≤ 2) at a mean of 3 days after procedure. The cumulative stent patency rates were 98.2 %, 95 %, 93.7 %, 91.5 %, 83.5 %, and 83.5 % at 1, 3, 6, 12, 18, and 24 months, respectively. Stent occlusion occurred in ten (8.8 %) of 114 patients at a mean of 215 days (range 1-732 days) due to thrombosis (n = 7) and tumor ingrowth (n = 3). Stent occlusion did not occur in 21 patients who underwent subsequent central venous catheter insertion. The median patient survival time was 159 days (95 % confidence interval 102-216 days). Univariate and multivariate Cox regression analysis revealed adjuvant anticancer treatment (p = 0.001) and tumor response (p < 0.001) as independent predictors of patient survival. CONCLUSIONS: Endovascular placement of large-bore uncovered stents was a safe and effective treatment for malignant superior vena cava syndrome. Large-bore stent placement can effectively prevent stent occlusion by tumor ingrowth in most cases, and it can provide a sufficient diameter for subsequent insertion of central venous catheters.


Subject(s)
Stents , Superior Vena Cava Syndrome , Humans , Superior Vena Cava Syndrome/diagnostic imaging , Superior Vena Cava Syndrome/surgery , Superior Vena Cava Syndrome/etiology , Superior Vena Cava Syndrome/therapy , Male , Middle Aged , Female , Aged , Adult , Retrospective Studies , Aged, 80 and over , Treatment Outcome , Young Adult , Endovascular Procedures/instrumentation , Endovascular Procedures/methods
13.
J Cardiovasc Surg (Torino) ; 65(2): 85-98, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635284

ABSTRACT

Endovascular aortic repair (EVAR) is nowadays the establishment treatment for patients with abdominal aortic aneurysm (AAA) both in elective and urgent setting. Despite the large applicability and satisfactory results, the presence of hostile iliac anatomy affects both technical and clinical success. This narrative review aimed to report the impact of iliac access and related adjunctive procedures in patients undergoing EVAR in elective and non-elective setting. Hostile iliac access can be defined in presence of narrowed, tortuous, calcified, or occluded iliac arteries. These iliac characteristics can be graded by the anatomic severity grade score to quantitatively assess anatomic complexity before undergoing treatment. Literature shows that iliac hostility has an impact on device navigability, insertion and perioperative and postoperative results. Overall, it has been correlated to higher rate of access issues, representing up to 30% of the first published EVAR experience. Recent innovations with low-profile endografts have reduced large-bore sheaths related issues. However, iliac-related complications still represent an issue, and several adjunctive endovascular and surgical strategies are nowadays available to overcome these complications during EVAR. In urgent settings iliac hostility can significantly impact on particular time sensitive procedures. Moreover, in case of severe hostility patients might be written off for EVAR repair might be inapplicable, exposing to higher mortality/morbidity risk in this urgent/emergent setting. In conclusion, an accurate anatomical evaluation of iliac arteries during preoperative planning, materials availability, and skilled preparation to face iliac-related issues are crucial to address these challenges.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Elective Surgical Procedures , Endovascular Procedures , Iliac Artery , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Iliac Artery/surgery , Iliac Artery/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Treatment Outcome , Risk Factors , Blood Vessel Prosthesis , Postoperative Complications/etiology
14.
J Cardiovasc Surg (Torino) ; 65(2): 119-123, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38618696

ABSTRACT

This article summarizes the key findings in literature up to date on the endovascular treatment of complex abdominal aortic aneurysms (AAAs) employing the chimney technique. Additionally, an unexplored pitfall is described regarding the target vessel angulation. Although balloon-expandable covered stents present more favorable configuration in downward-oriented target vessels, transverse and upward-oriented target vessels may benefit from other endovascular techniques imploring careful case planning and further investigation on the topic.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Renal Artery , Stents , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Humans , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Renal Artery/surgery , Renal Artery/diagnostic imaging , Treatment Outcome , Endovascular Procedures/instrumentation , Prosthesis Design , Risk Factors
15.
J Cardiovasc Surg (Torino) ; 65(2): 124-131, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635285

ABSTRACT

INTRODUCTION: We performed a systematic review and meta-analysis to assess the existing published evidence regarding the safety and efficacy of the endovascular aortic repair with chimney technique (ch-EVAR) and physician-modified stent-grafts (PMSGs) for the treatment of pararenal aortic aneurysm repair. EVIDENCE ACQUISITION: A systematic search of all relevant studies reported until October 2023 according to the PRISMA (preferred reporting items for systematic reviews and meta-analyses) guidelines was performed. The pooled 30-day mortality, peri- and postoperative complication rates were estimated using fixed or random effect methods. EVIDENCE SYNTHESIS: A total of 679 study titles were identified by the initial search strategy, of which 16 were considered eligible for inclusion in the meta-analysis. A total of 1094 patients (ch-EVAR N.=861 and PMSG N.=233) (90% male) were identified. The pooled 30-day mortality rate was 3.4% for ch-EVAR and 2.6% for PMSG. The major adverse events (MAE) in the early period was 14.7% for ch-EVAR and 18.5% PMSG, respectively. Higher occlusion rate was observed of the chimney stents grafts (8.2%) than the bridging stents (1.4%) during the follow-up period. CONCLUSIONS: Ch-EVAR and physician-modified technology are safe with low 30-day mortality in elective settings for pararenal aortic aneurysms repair. No significant differences were seen between the two surgical methods regarding the early major adverse events rate. However, higher occlusion rate for the chimneys can be expected over time.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Postoperative Complications , Prosthesis Design , Stents , Humans , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Endovascular Procedures/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Treatment Outcome , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/mortality , Aortic Aneurysm, Abdominal/diagnostic imaging , Postoperative Complications/etiology , Risk Factors , Male , Female , Aged , Time Factors , Risk Assessment , Middle Aged
16.
J Cardiovasc Surg (Torino) ; 65(2): 110-118, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635286

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the anatomical feasibility of current available fenestrated endografts (FEVAR) and on-label chimney technique (EnChEVAR) in patients with complex abdominal aortic aneurysms (C-AAA). METHODS: Feasibility of EnChEVAR (Endurant II/IIS CE-marked [Medtronic]) and 4 types of FEVAR (Zenith Fenestrated CE-marked, Zenith Fenestrated Low-Profile [LP] custom-made device [CMD] [Cook Medical], Fenestrated Anaconda LoPro90 CMD, Fenestrated Treo CMD [Terumo Aortic]) was assessed according to the manufacturer's instructions for use. Computed tomography angiograms of patients with C-AAA previously included in the Protagoras 2.0 study were retrospectively reviewed. The aortic coverage was ideally planned to involve a maximum of two chimney grafts or fenestrations. RESULTS: Iliac access and aortic neck of 73 C-AAAs were analyzed. The overall feasibility was significantly different between EnChEVAR (33%) and FEVAR (Zenith Fenestrated 15%, Zenith Fenestrated LP 15%, Fenestrated Anaconda LoPro90 45%, Fenestrated Treo 48%). The iliac access feasibility was significantly lower for Zenith Fenestrated with standard profile compared to all other grafts. The aortic neck feasibility was significantly higher for EnChEVAR and both Terumo Aortic fenestrated stent grafts, compared to both Cook Medical grafts. The treatment using any of the three current available fenestrated grafts with lower profile (Zenith Fenestrated LP, Fenestrated Anaconda LoPro90, Fenestrated Treo) would have been feasible in 71% of the cases. CONCLUSIONS: Most of the patients treated by ChEVAR would have not been treated by first generation fenestrated stent graft. The current available fenestrated endografts, with lower profile and suitable also for angulated necks, increase the anatomical feasibility.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Computed Tomography Angiography , Endovascular Procedures , Feasibility Studies , Prosthesis Design , Stents , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Endovascular Procedures/instrumentation , Endovascular Procedures/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Retrospective Studies , Female , Male , Aged , Treatment Outcome , Aged, 80 and over , Contrast Media , Aortography
17.
J Cardiovasc Surg (Torino) ; 65(2): 106-109, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635287

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the early results of the CE-marked standardized device combination consisting of Endurant and the Radiant chimney graft (En-ChEVAR) for the treatment of juxtarenal aortic aneurysms. METHODS: We analyzed multicentric non-industry sponsored case series evaluating the EnChEVAR technique for patients treated between December 2022 and February 2024. Clinical, perioperative procedure-related and radiological data were collected. The primary outcome measure was the freedom of a type Ia gutter-related endoleak at postoperative computed tomography angiography (CTA). Secondary outcome measures included early type Ia endoleak-related reinterventions, target vessel complications including dissection or loss of target vessel, major adverse events, and mortality. Continuous variables were presented as median (interquartile range [IQR]) and categorical variables as count and percentage. RESULTS: Ten patients were included in the present study. Eight (80%) were males, in nine cases a single chimney was implanted, and the other one was a double chimney graft placement. The treated aneurysms had an infrarenal neck length of 3.4 (1.2) mm. The rate of main body oversizing was 30%. The new neck length after chimney graft placement was 18 (3) mm. The median procedural time was 130 (17) mm, contrast medium use was 109 (26) mL, radiation time was 45 (12) min. The technical success was 100%. No type Ia endoleak was detected at the postoperative CTA. There were no target vessel issues. No major adverse events or death were observed. CONCLUSIONS: First reported cohort of patients treated with EnChEVAR demonstrated reproducible clinical and procedural outcomes within the 3 vascular centers with total exclusion of the aneurysms, patent renal arteries, and no evidence of gutter-related type IA endoleak. Further evidence with larger sample size of treated patients and longer follow-up are needed.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endoleak , Endovascular Procedures , Prosthesis Design , Registries , Humans , Male , Female , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Aged , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Endoleak/etiology , Time Factors , Treatment Outcome , Aged, 80 and over , Stents , Retrospective Studies , Risk Factors , Product Labeling , Endovascular Aneurysm Repair
18.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38569918

ABSTRACT

OBJECTIVES: Our goal was to access early and mid-term outcomes of a gutter-plugging chimney stent graft for treatment of Stanford type B aortic dissections in the clinical trial Prospective Study for Aortic Arch Therapy with stENt-graft for Chimney technology (PATENCY). METHODS: Between October 2018 and March 2022, patients with Stanford type B aortic dissections were treated with the Longuette chimney stent graft in 26 vascular centres. The efficiency and the incidence of adverse events over 12 months were investigated. RESULTS: A total of 150 patients were included. The technical success rate was 99.33% (149/150). The incidence of immediate postoperative endoleak was 5.33% (8/150, type I, n = 6; type II, n = 1; type IV, n = 1) neurologic complications (stroke or spinal cord ischaemia); the 30-day mortality was 0.67% (1/150) and 1.33% (2/150), respectively. During the follow-up period, the median follow-up time was 11.67 (5-16) months. The patent rate of the Longuette graft was 97.87%. Two patients with type I endoleak underwent reintervention. The follow-up rate of the incidence of retrograde A type aortic dissection was 0.67% (1/150). There was no paraplegia, left arm ischaemia or stent migration. CONCLUSIONS: For revascularization of the left subclavian artery, the Longuette chimney stent graft can provide an easily manipulated, safe and effective endovascular treatment. It should be considered a more efficient technique to prevent type Ia endoleak. Longer follow-up and a larger cohort are needed to validate these results. CLINICAL TRIAL REGISTRY NUMBER: NCT03767777.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Stents , Adult , Aged , Female , Humans , Male , Middle Aged , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/instrumentation , Endovascular Procedures/methods , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Prospective Studies , Prosthesis Design , Stents/adverse effects , Treatment Outcome , Case-Control Studies
19.
AJNR Am J Neuroradiol ; 45(5): 605-611, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38514090

ABSTRACT

BACKGROUND AND PURPOSE: Endovascular treatment of wide-neck bifurcation aneurysms has historically proved difficult with variable outcomes. Different endovascular techniques such as balloon-assisted coiling, stent-assisted coiling, or intrasaccular devices provide a varied range of efficacy and safety. Neqstent-assisted coiling is a new device and technique that aim to provide a maximum of both. We analyzed the early clinical and radiologic outcomes after the use of this new technique and device in our practice. MATERIALS AND METHODS: This study was a retrospective analysis of ruptured and unruptured intracranial aneurysms treated with the Neqstent. The primary radiologic outcomes were quantified on DSA, CTA, or MRA using the modified Raymond-Roy criteria. The outcomes were defined as immediate complete occlusion (modified Raymond-Roy criteria 1) and complete (modified Raymond-Roy criteria 1) and adequate occlusion (modified Raymond-Roy criteria 1 and modified Raymond-Roy criteria 2) at 6 months posttreatment. The primary safety outcome was the rate of device-related adverse events. Secondary safety outcomes included time to discharge and change in the mRS score at 6-month follow-up. RESULTS: Twenty patients were treated with the Neqstent from November 2020 to January 2023. Nine had unruptured aneurysms, and 11 were patients with subarachnoid haemorrhage due to ruptured aneurysms. Eighteen of 20 aneurysms (90%) treated demonstrated complete occlusion (modified Raymond-Roy criteria 1) on immediate postembolization angiograms. Sixteen of 17 aneurysms treated (94.1%) remained adequately occluded on 6-month follow-up (modified Raymond-Roy criteria 1 and modified Raymond-Roy criteria 2). Immediate postoperative complications occurred in 2 patients; only 1 patient had residual neurologic deficits at 6 months (mRS = 2). CONCLUSIONS: Management of large, wide-neck aneurysms remains difficult, with high rates of recurrence and complications. The use of the Neqstent shows promising short-term results for the treatment of complex wide-neck aneurysms. Initial complication rates for our cohort were relatively high. However, this result is likely related to the initial learning experience of device deployment and the use of antiplatelets.


Subject(s)
Aneurysm, Ruptured , Endovascular Procedures , Intracranial Aneurysm , Humans , Male , Female , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Intracranial Aneurysm/surgery , Middle Aged , Retrospective Studies , Aged , Endovascular Procedures/instrumentation , Endovascular Procedures/methods , Follow-Up Studies , Aneurysm, Ruptured/diagnostic imaging , Aneurysm, Ruptured/therapy , Aneurysm, Ruptured/surgery , Treatment Outcome , Stents , Adult , Embolization, Therapeutic/instrumentation , Embolization, Therapeutic/methods , Cerebral Angiography
20.
J Vasc Interv Radiol ; 35(6): 874-882, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38479451

ABSTRACT

PURPOSE: To evaluate the effectiveness and safety of pre-emptive transcatheter arterial embolization (P-TAE) for aortic side branches (ASBs) to prevent Type 2 endoleaks (EL2) before endovascular aneurysm repair (EVAR) using the Excluder stent-graft system (Excluder). MATERIALS AND METHODS: In this prospective, multicenter study, 80 patients (mean age, 79.1 years [SD ± 6.7]; 85.0% were men; mean aneurysmal sac diameter, 48.4 mm [SD ± 7.4]) meeting the eligibility criteria were prospectively enrolled from 9 hospitals. Before EVAR, P-TAE was performed to embolize the patent ASBs originating from the abdominal aortic aneurysm. Contrast-enhanced computed tomography (CT) was performed at 1 month and 6 months after EVAR. The primary endpoint was EL2 incidence at 6 months, and the secondary endpoints were aneurysmal sac diameter changes at 6 and 12 months, P-TAE outcomes, adverse events related to P-TAE, reintervention, and aneurysm-related mortality. RESULTS: All patients successfully underwent P-TAE without serious. Coil embolization was successful in 81.6% of ASBs. EL2 incidence at 6 months was identified in 18 of 70 (25.7%) patients. Aneurysmal sac diameter shrinkage (≥5 mm) was observed in 30.0% of patients at 6 months and in 40.9% at 12 months. Only 1 patient required reintervention for EL2 within 1 year of EVAR; aneurysm-related deaths were not observed. CONCLUSIONS: P-TAE for ASBs before EVAR using Excluder is a safe and effective strategy. It aids in achieving early aneurysmal sac shrinkage and reduces EL2 reintervention at 1 year after EVAR.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Computed Tomography Angiography , Embolization, Therapeutic , Endoleak , Endovascular Procedures , Prosthesis Design , Stents , Humans , Female , Male , Aged , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Prospective Studies , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Embolization, Therapeutic/adverse effects , Embolization, Therapeutic/instrumentation , Treatment Outcome , Aged, 80 and over , Endoleak/etiology , Endoleak/therapy , Endoleak/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Time Factors , Aortography , Risk Factors , Japan , Endovascular Aneurysm Repair
SELECTION OF CITATIONS
SEARCH DETAIL
...