Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24.504
Filter
1.
Neurosurg Focus ; 56(6): E12, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38823042

ABSTRACT

OBJECTIVE: The aim of this study was 1) to describe the rate of intrathecal baclofen (ITB)-associated complications at a large tertiary center, and 2) to evaluate the impact of patient-related factors on the likelihood of developing such complications. METHODS: A retrospective single-center study was carried out. A total of 301 eligible patients were included in the analysis. Univariate regression models were used to evaluate the impact of age, sex, diagnosis, ambulation status, modified Ashworth scale score, body mass index, diabetes status, and pain level on the likelihood of developing a device-related infection, pump malfunction, catheter malfunction, and other clinically significant complications. RESULTS: Overall, 27% of patients experienced an ITB-related complication. The most common complications included infection (6%, 18/301), pump malfunction (7.3%, 22/301), and catheter malfunction (14%, 42/301). The univariate analyses revealed that the patient's ambulatory status had a significant impact on the likelihood of developing a catheter-related malfunction. Furthermore, a trend toward significance was identified between patients' preoperative body mass index and device-related infection. Finally, the risk of suffering any ITB-related complications was statistically correlated with the number of years that had passed since the initial pump implantation. CONCLUSIONS: The authors' analysis reveals a previously underrecognized association between ambulatory status at the time of ITB pump implantation and the incidence of catheter-related complications, and confirms the impact of time since surgery on the risk of developing any ITB-related complication. The patient's age, sex, diagnosis, diabetes status, or pain level at baseline were not associated with the risk of complications. Collectively, these insights contribute novel information to the existing literature, providing practical value for physicians in guiding patient selection for ITB therapy.


Subject(s)
Baclofen , Infusion Pumps, Implantable , Injections, Spinal , Muscle Relaxants, Central , Humans , Baclofen/administration & dosage , Baclofen/adverse effects , Male , Female , Middle Aged , Retrospective Studies , Adult , Risk Factors , Infusion Pumps, Implantable/adverse effects , Muscle Relaxants, Central/administration & dosage , Muscle Relaxants, Central/adverse effects , Injections, Spinal/adverse effects , Aged , Young Adult , Muscle Spasticity/drug therapy , Equipment Failure/statistics & numerical data , Adolescent
2.
Neurosurg Focus ; 56(6): E11, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38823047

ABSTRACT

OBJECTIVE: Intrathecal baclofen (ITB) pumps are commonly used in pediatric patients with cerebral palsy (CP) and medically refractory spasticity. However, catheter malfunction and associated risk factors are not well understood. The aim of this study was to examine potential risk factors for spinal catheter malfunction and characterize postoperative follow-up to understand the clinical consequences. METHODS: Patients who received ITB pump replacement or revision at Boston Children's Hospital between 2010 and 2023 were retrospectively reviewed. The spinal catheter revision cohort (SCRC) included patients whose spinal catheter was occluded requiring lumbar catheter revision. The second cohort included abdominal pump replacements only (APRC). Between-group comparisons and multivariable regression identified factors associated with catheter revision and postoperative outcomes. RESULTS: Forty-one (33.6%) patients underwent spinal catheter revision and were compared with 81 patients (66.4%) who underwent abdominal pump replacement only. Younger age at surgery and an elevated preoperative lower-extremity modified Ashworth scale grade were associated with spinal catheter revision (p < 0.05). Catheter model type, tip location, and history of spinal fusion were not associated with obstruction. Postoperatively, SCRC patients experienced a higher rate of infection (17.1%) relative to APRC patients (0%) within 30 days from their ITB pump replacement procedure (p < 0.05) and greater likelihood of subsequent ITB system removal compared with the APRC (24.4% vs 7.4%, p < 0.05). Although not differing preoperatively, SCRC patients had lower postoperative ITB doses when compared with the APRC group (median dose 143 vs 350 µg/day, p < 0.05) at hospital discharge and remained statistically different at the 6-month and 1-year follow-ups (p < 0.05). There were no postoperative differences in baclofen overdose, withdrawal, or median number of hospital readmissions within 30 days. Overall, 31.7% of spinal catheter revisions were unanticipated by the clinical team at time of surgery. CONCLUSIONS: Younger age at surgery and increased preoperative lower-extremity tone may be risk factors for catheter obstruction, resulting in a higher rate of postoperative infection and subsequent ITB pump removal compared with pump replacement alone. Spinal catheter occlusion can complicate revision or replacement procedures, especially when unanticipated. Routine clinical assessment may be inadequate for diagnosing insidious catheter malfunction. Catheter occlusion deserves further study, and routine assessment of catheter patency may be warranted to prevent suboptimal tone therapy.


Subject(s)
Baclofen , Cerebral Palsy , Infusion Pumps, Implantable , Muscle Relaxants, Central , Humans , Baclofen/administration & dosage , Baclofen/adverse effects , Male , Female , Child , Infusion Pumps, Implantable/adverse effects , Risk Factors , Muscle Relaxants, Central/administration & dosage , Retrospective Studies , Adolescent , Cerebral Palsy/surgery , Cerebral Palsy/complications , Child, Preschool , Muscle Spasticity/drug therapy , Muscle Spasticity/etiology , Muscle Spasticity/surgery , Reoperation/methods , Injections, Spinal/methods , Treatment Outcome , Postoperative Complications/etiology , Equipment Failure , Cohort Studies
3.
J Cardiothorac Surg ; 19(1): 306, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38822410

ABSTRACT

Peripheral venous catheter fracture with cardiovascular embolization is a rare but potentially serious complication. Herein, we report a case of peripheral venous catheter fracture with embolization in right ventricle in a preterm infant. The catheter fragment was successfully removed by surgical procedure via median sternotomy under cardiopulmonary bypass(CPB).We hope this case will increase awareness of this rare complication and improve cannulation safety.


Subject(s)
Catheterization, Peripheral , Device Removal , Infant, Premature , Humans , Infant, Newborn , Catheterization, Peripheral/methods , Device Removal/methods , Male , Equipment Failure , Heart Ventricles/surgery , Female
4.
Forensic Sci Int ; 359: 112001, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38714107

ABSTRACT

BACKGROUND: Cardiac implantable electronic devices (CIED) are a heterogeneous group of medical devices with increasingly sophisticated diagnostic capabilities, which could be exploited in forensic investigations. However, current guidelines are lacking clear recommendations on the topic. The first aim of this systematic review is to provide an updated assessment of the role of postmortem CIED interrogation, and to give practical recommendations, which can be used in daily practice. Secondly, the authors aim to determine the rates of postmortem CIED interrogation and autopsy investigations, the type of final rhythm detected close to death (with a focus on the significance of documented arrhythmias), as well as the role of postmortem CIED interrogation in the determination of final cause/time of death, and any potentially fatal device malfunctions. METHODS: A systematic search in MEDLINE and Scopus aiming to identify reports concerning postmortem human CIED interrogation was performed, including a systematic screening of reference lists. Case reports, letters to the editors, commentaries, review articles or guidelines were excluded, along with studies related to cardiac devices other than CIED. All data were pooled and analyzed using fixed-effects meta-analysis models, and the I2 statistic was used to assess heterogeneity. RESULTS: A total of 25 articles were included in the systematic review, enrolling 3194 decedent CIED carriers. Ten studies (40%) had a 100% autopsy rate, whereas in further 6 studies autopsy findings were variably reported; CIED interrogation was available from 22 studies (88%), and it was never performed prior to autopsy. The overall rate of successful postmortem CIED interrogation was 89%, with high heterogeneity among studies, mainly due to device deactivation/battery discharge. Twenty-four percent of CIED carriers experienced sudden cardiac death (SCD), whereas non-sudden cardiac and non-cardiac death (NSCD, NCD) were reported in 37% and 30% of decedents, respectively. Ventricular tachyarrhythmias were recorded in 34% of overall successfully interrogated CIED, and in 62% of decedents who experienced a SCD; of all ventricular tachyarrhythmias recorded, 40% was found in NSCD or NCD. A clear interpretation of the etiological role of recorded arrhythmias in the causation of death required integration with autopsy findings. Overall, potentially fatal device malfunctions were detected in 12% of cases. CONCLUSIONS: Postmortem CIED interrogation is a valuable tool for the determination of the cause of death, and may complement autopsy. Forensic pathologists need to know the potential utility, pitfalls, and limitations of this diagnostic examination to make this tool as much reliable as possible.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Pacemaker, Artificial/adverse effects , Arrhythmias, Cardiac , Equipment Failure
5.
PLoS One ; 19(5): e0303152, 2024.
Article in English | MEDLINE | ID: mdl-38722995

ABSTRACT

INTRODUCTION: Short peripheral intravenous catheter (PIVC) failure is a common complication that is generally underdiagnosed. Some studies have evaluated the factors associated with these complications, but the impact of care complexity individual factors and nurse staffing levels on PIVC failure is still to be assessed. The aim of this study was to determine the incidence and risk factors of PIVC failure in the public hospital system of the Southern Barcelona Metropolitan Area. METHODS: A retrospective multicentre observational cohort study of hospitalised adult patients was conducted in two public hospitals in Barcelona from 1st January 2016 to 31st December 2017. All adult patients admitted to the hospitalisation ward were included until the day of discharge. Patients were classified according to presence or absence of PIVC failure. The main outcomes were nurse staffing coverage (ATIC patient classification system) and 27-care complexity individual factors. Data were obtained from electronic health records in 2022. RESULTS: Of the 44,661 patients with a PIVC, catheter failure was recorded in 2,624 (5.9%) patients (2,577 [5.8%] phlebitis and 55 [0.1%] extravasation). PIVC failure was more frequent in female patients (42%), admitted to medical wards, unscheduled admissions, longer catheter dwell time (median 7.3 vs 2.2 days) and those with lower levels of nurse staffing coverage (mean 60.2 vs 71.5). Multivariate logistic regression analysis revealed that the female gender, medical ward admission, catheter dwell time, haemodynamic instability, uncontrolled pain, communication disorders, a high risk of haemorrhage, mental impairments, and a lack of caregiver support were independent factors associated with PIVC failure. Moreover, higher nurse staffing were a protective factor against PIVC failure (AUC, 0.73; 95% confidence interval [CI]: 0.72-0.74). CONCLUSION: About 6% of patients presented PIVC failure during hospitalisation. Several complexity factors were associated with PIVC failure and lower nurse staffing levels were identified in patients with PIVC failure. Institutions should consider that prior identification of care complexity individual factors and nurse staffing coverage could be associated with a reduced risk of PIVC failure.


Subject(s)
Catheterization, Peripheral , Humans , Female , Male , Retrospective Studies , Catheterization, Peripheral/adverse effects , Middle Aged , Aged , Risk Factors , Adult , Personnel Staffing and Scheduling , Equipment Failure/statistics & numerical data , Nursing Staff, Hospital/statistics & numerical data , Hospitalization/statistics & numerical data , Spain/epidemiology
7.
Card Electrophysiol Clin ; 16(2): 163-168, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749636

ABSTRACT

A 69-year-old woman with a history of heart failure with reduced ejection fraction presented for device interrogation of her cardiac implantable electronic device (CIED), revealing lead and pulse generator displacement. Surprisingly, she exhibited a narrow QRS on the ECG despite an underlying right bundle branch block, suggesting unintentional conduction system pacing (CSP). Traditional cardiac resynchronization therapy has been widely used for patients with heart failure, but alternatives like CSP are emerging as viable options. Given the global rise in CIED utilization, regular follow-up, device troubleshooting, and embracing remote monitoring are essential to manage and optimize patient outcomes.


Subject(s)
Cardiac Resynchronization Therapy Devices , Cardiac Resynchronization Therapy , Heart Failure , Humans , Female , Aged , Heart Failure/therapy , Heart Failure/physiopathology , Electrocardiography , Equipment Failure , Heart Conduction System/physiopathology , Bundle-Branch Block/therapy , Bundle-Branch Block/physiopathology
8.
Cochrane Database Syst Rev ; 5: CD013023, 2024 05 23.
Article in English | MEDLINE | ID: mdl-38780138

ABSTRACT

BACKGROUND: Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail, requiring reinsertion. Dressings and securement devices maintain AC function and prevent complications such as infection. OBJECTIVES: To evaluate the effectiveness of peripheral AC dressing and securement devices to prevent failure and complications in hospitalised people. SEARCH METHODS: We searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL Plus up to 16 May 2023. We also searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform up to 16 May 2023. SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing different dressing and securement devices for the stabilisation of ACs in hospitalised people. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials for inclusion, extracted data, and assessed risk of bias using Cochrane's RoB 1 tool. We resolved disagreements by discussion, or by consulting a third review author when necessary. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included five RCTs with 1228 participants and 1228 ACs. All included studies had high risk of bias in one or more domains. We present the following four comparisons, with the remaining comparisons reported in the main review. Standard polyurethane (SPU) plus tissue adhesive (TA) compared with SPU: we are very uncertain whether use of SPU plus TA impacts rates of AC failure (risk ratio (RR) 0.44, 95% confidence interval (CI) 0.20 to 0.98; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Neither study (165 participants) reported catheter-related bloodstream infections (CRBSI), thus we are very uncertain whether SPU plus TA impacts on the incidence of CRBSI (very low-certainty evidence). It is very uncertain whether use of SPU plus TA impacts AC dislodgement risk (RR 0.54, 95% CI 0.03 to 9.62; I² = 44%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts AC occlusion rates (RR 1.20, 95% CI 0.37 to 3.91; I² = 3%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts rates of adverse events with few reported events across groups (RR 0.89, 95% CI 0.09 to 8.33; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Bordered polyurethane (BPU) compared to SPU: we are very uncertain whether use of BPU impacts rates of AC failure (RR 0.67, 95% CI 0.21 to 2.13; 1 study, 60 participants; very low-certainty evidence). BPU may make little or no difference to CRBSI compared to SPU (RR 3.05, 95% CI 0.12 to 74.45; I² = not applicable as 1 study (60 participants) reported 0 events; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to the risk of AC dislodgement compared with SPU (RR 0.75, 95% CI 0.17 to 3.22; I² = 0%; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to occlusion risk compared with SPU (RR 0.80, 95% CI 0.60 to 1.07; I² = 0%; 2 studies, 572 participants; low-certainty evidence). It is very uncertain whether BPU impacts on the risk of adverse events compared with SPU (RR 0.33, 95% CI 0.01 to 7.87; 1 study, 60 participants; very low-certainty evidence). SPU plus sutureless securement devices (SSD) compared to SPU: we are very uncertain whether SPU plus SSD impacts risk of AC failure compared with SPU (RR 0.78, 95% CI 0.40 to 1.52; I² = 0%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain if SPU plus SSD impacts CRBSI incidence rate with no events in both groups (2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of dislodgement (RR 0.14, 95% CI 0.01 to 2.57; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of AC occlusion (RR 1.94, 95% CI 0.50 to 7.48; I² = 38%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain whether SPU plus SSD impacts on the risk of adverse events (RR 1.94, 95% CI 0.19 to 20.24; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). Integrated securement dressings compared to SPU: integrated securement dressings may result in little or no difference in risk of AC failure compared with SPU (RR 1.96, 95% CI 0.80 to 4.84; 1 study, 105 participants; low-certainty evidence); may result in little or no difference in CRBSI incidence with no events reported (1 study, 105 participants; low-certainty evidence); may result in little or no difference in the risk of dislodgement (RR 0.33, 95% CI 0.04 to 3.04; 1 study, 105 participants; low-certainty evidence), may result in little or no difference in occlusion rates with no events reported (1 study, 105 participants; low-certainty evidence), and may result in little or no difference in the risk of adverse events (RR 0.35, 95% CI 0.01 to 8.45; 1 study, 105 participants; low-certainty evidence). AUTHORS' CONCLUSIONS: There is currently limited rigorous RCT evidence available about the relative clinical effectiveness of AC dressing and securement products. Limitations of current evidence include small sample size, infrequent events, and heterogeneous outcome measurements. We found no clear difference in the incidence of AC failure, CRBSI, or adverse events across AC dressing or securement products including SPU, BPU, SSD, TA, and integrated securement products. The limitations of current evidence means further rigorous RCTs are needed to reduce uncertainty around the use of dressing and securement devices for ACs.


Subject(s)
Bandages , Catheter-Related Infections , Catheterization, Peripheral , Polyurethanes , Randomized Controlled Trials as Topic , Humans , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Catheter-Related Infections/prevention & control , Bias , Equipment Failure
9.
BMJ Open ; 14(5): e081749, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38760049

ABSTRACT

OBJECTIVES: To compare catheter-related outcomes of individuals who received a tunnelled femorally inserted central catheter (tFICC) with those who received a peripherally inserted central catheter (PICC) in the upper extremities. DESIGN: A propensity-score matched cohort study. SETTING: A 980-bed tertiary referral hospital in South West Sydney, Australia. PARTICIPANTS: In-patients referred to the hospital central venous access service for the insertion of a central venous access device. PRIMARY AND SECONDARY OUTCOME MEASURES: The primary outcome of interest was the incidence of all-cause catheter failure. Secondary outcomes included the rates of catheters removed because of suspected or confirmed catheter-associated infection, catheter dwell and confirmed upper or lower extremity deep vein thrombosis (DVT). RESULTS: The overall rate of all-cause catheter failure in the matched tFICC and PICC cohort was 2.4/1000 catheter days (95% CI 1.1 to 4.4) and 3.0/1000 catheter days (95% CI 2.3 to 3.9), respectively, and when compared, no difference was observed (difference -0.63/1000 catheter days, 95% CI -2.32 to 1.06). We found no differences in catheter dwell (mean difference of 14.2 days, 95% CI -6.6 to 35.0, p=0.910); or in the cumulative probability of failure between the two groups within the first month of dwell (p=0.358). No significant differences were observed in the rate of catheters requiring removal for confirmed central line-associated bloodstream infection (difference 0.13/1000 catheter day, 95% CI -0.36 to 0.63, p=0.896). Similarly, no significant differences were found between the groups for confirmed catheter-related DVT (difference -0.11 per 1000 catheter days, 95% CI -0.26 to 0.04, p=1.00). CONCLUSION: There were no differences in catheter-related outcomes between the matched cohort of tFICC and PICC patients, suggesting that tFICCs are a possible alternative for vascular access when the veins of the upper extremities or thoracic region are not viable for catheterisation.


Subject(s)
Catheter-Related Infections , Catheterization, Central Venous , Catheterization, Peripheral , Propensity Score , Humans , Female , Male , Middle Aged , Catheter-Related Infections/epidemiology , Catheter-Related Infections/etiology , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/methods , Catheterization, Peripheral/adverse effects , Aged , Central Venous Catheters/adverse effects , Cohort Studies , Australia/epidemiology , Adult , Catheters, Indwelling/adverse effects , Device Removal/statistics & numerical data , Equipment Failure/statistics & numerical data
10.
PeerJ ; 12: e17418, 2024.
Article in English | MEDLINE | ID: mdl-38799069

ABSTRACT

Aim: Assess the effect of simulated clinical use and sterilization on the cyclic fatigue resistance of Race Evo and Tia Tornado Blue nickel titanium (NiTi) files. Materials and Methods: For this study, a total of sixty-four NiTi files were selected, with thirty-two files each from two different manufacturers. Files from each manufacturer were subdivided into four subgroups (n = 8) based on the test parameters. The control groups included files that were neither used nor sterilized. Files from the test groups were used to prepare the root canals of extracted mandibular premolars and then sterilized. This procedure was repeated once, twice, or thrice, depending on the test group. All files were then subjected to a cyclic fatigue test. Data was statistically analyzed using the Kruskal-Wallis and Mann-Whitney U tests. Results: No significant difference was observed in the number of cycles to failure (NCF) among the subgroups for both types of files (P = 0.869 for Tia Tornado Blue, P = 0.626 for Race Evo). Tia Tornado Blue files displayed significantly higher NCF values in the control (P = 0.021), once (P = 0.027), and thrice (P = 0.031) usage groups when compared to Race Evo files. Conclusions: Repeated clinical use and sterilization for up to three cycles did not affect the cyclic fatigue resistance of Race Evo and Tia Tornado Blue files.


Subject(s)
Nickel , Sterilization , Titanium , Sterilization/methods , Humans , Equipment Failure , Materials Testing , Root Canal Preparation/instrumentation
11.
BMC Oral Health ; 24(1): 585, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38773530

ABSTRACT

Periodontal instrument fractures are rare events in dentistry, with limited literature available on their occurrence and management. This case report highlights an incident involving the fracture of a periodontal sickle scaler blade during manual instrumentation for the removal of calculus. The fracture occurred during instrumentation on the mesial surface of the maxillary right second molar, and the separated blade was subsequently pushed into the sulcus. A radiographic assessment was performed to verify the precise location of the fractured segment. Following confirmation, the broken blade was subsequently retrieved using curved artery forceps. The case report highlights factors contributing to instrument fractures, emphasizing the importance of instrument maintenance, sterilization cycles, and operator technique. Ethical considerations regarding patient disclosure, informed consent, and instrument retrieval methods are well discussed. This case underscores the importance of truthful communication, the proper use of instruments, equipment maintenance in dentistry, and the significance of ongoing professional development to enhance treatment safety, proficiency, and ethical standards in dental care.


Subject(s)
Equipment Failure , Humans , Male , Dental Instruments/adverse effects , Dental Scaling , Ethics, Dental , Middle Aged
12.
Dent Med Probl ; 61(2): 269-278, 2024.
Article in English | MEDLINE | ID: mdl-38686969

ABSTRACT

Nickel-titanium (NiTi) file separation during endodontic treatment is an undesirable event. This phenomenon needs to be understood by knowing the factors influencing fracture in endodontic files. There is a large amount of literature where these factors and their influence have been studied, increasing the knowledge about the mechanisms involved, mainly related to wire technology, file shapes and geometry, operator manipulation, the anatomy of the root canal, and the irrigation and sterilization processes. As many factors are involved, the complexity of the fracture phenomena increases and the isolated correlation of one factor with the file fracture becomes a small part of comprehending the separation phenomena. This thematic review aims to compile important reports from 2014 to 2022 on the factors influencing NiTi file separation. The information obtained was classified into wire technology, file geometry, operational aspects, irrigation and sterilization, and anatomy. For this purpose, the Scopus, Web of Science and ScienceDirect databases were consulted using a search string. Filters were applied to consolidate the final set of relevant papers covering the subject of factors influencing endodontic file separation. It was found that the fracture of NiTi files incorporates different mechanisms that operate simultaneously during the endodontic procedure and strongly affect the instrument performance. The collected information promotes good practices to prevent file separation.


Subject(s)
Nickel , Root Canal Preparation , Titanium , Humans , Root Canal Preparation/instrumentation , Equipment Failure , Equipment Design , Sterilization , Dental Instruments
13.
JAMA Pediatr ; 178(5): 437-445, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38558161

ABSTRACT

Importance: Peripheral intravenous catheters (PIVCs) facilitate essential treatment. Failure of these essential devices is frequent and new securement strategies may reduce failure and improve patient outcomes. Objective: To evaluate clinical effectiveness of novel PIVC securement technologies for children to reduce catheter failure. Design, Setting, and Participants: A 3-arm, parallel group, superiority randomized clinical trial was conducted at 2 regional Australian hospitals from February 5, 2020, to January 14, 2022. Children aged 6 months to 8 years who were anticipated to require admission with a PIVC for at least 24 hours of in hospital treatment were eligible. Data were analyzed from May 25, 2022, to February 20, 2024. Interventions: Participants were randomly allocated in a 1:1:1 ratio to standard care, bordered polyurethane (Tegaderm [3M]), integrated securement dressing (SorbaView SHIELD [Medline]), and integrated securement dressing with tissue adhesive (Secureport IV). One catheter was studied per patient. Main Outcomes and Measures: Primary outcome was PIVC failure, defined as premature cessation of PIVC function for any reason prior to completion of planned treatment. Secondary outcomes were PIVC complications (any time dislodgement, occlusion, infiltration, partial dislodgement, extravasation, device leaking, phlebitis, pain), PIVC longevity, intervention acceptability (clinicians, participants, caregivers; 0-10 scale), and pain on removal (participants and caregivers; 0-10 scale relevant to age), adverse events, and health care costs. Results: A total of 383 patients (51% female; median age 36 [25th-75th percentiles, 22-72] months) were randomized 134 to standard care, 118 to integrated securement dressing, and 131 to integrated securement dressing with tissue adhesive. PIVC failure was lowest in integrated securement dressing with tissue adhesive (15 [12%]; adjusted hazard ratio [aHR], 0.47; 95% CI, 0.26-0.84) compared with integrated securement dressing (24 [21%]; aHR, 0.78; 95% CI, 0.47-1.28) and standard care (43 [34%]). Direct costs were significantly lower for integrated securement dressing with tissue adhesive (median, Australian dollars [A$], 312 [A$1 is equal to $0.65 US dollars]; IQR, A$302-A$380) and integrated securement dressing (median, A$303; IQR, A$294-A$465) compared with standard care (median, A$341; IQR, A$297-A$592; P ≤ .002) when considering the economic burden related to failure of devices. PIVC longevity and intervention acceptability were similar across all groups. Conclusions and Relevance: In this study, PIVCs secured with integrated securement dressings and tissue adhesive, in comparison with standard care, bordered polyurethane dressings, were associated with significantly reduced PIVC failure, for children admitted to hospital via the emergency department. Further research should focus on implementation in inpatient units where prolonged dwell and reliable intravenous access is most needed. Trial Registration: Australian New Zealand Clinical Trials Registry Identifier: ACTRN12619001026112.


Subject(s)
Catheterization, Peripheral , Equipment Failure , Humans , Female , Male , Catheterization, Peripheral/methods , Catheterization, Peripheral/instrumentation , Catheterization, Peripheral/economics , Child , Child, Preschool , Infant , Bandages/economics , Australia , Polyurethanes , Tissue Adhesives/administration & dosage
14.
Injury ; 55(6): 111533, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38631082

ABSTRACT

Diaphyseal fractures of the tibia is a common injury with an incidence of 16.9/100,000 population. Surgical treatment with intramedullary interlocking nail is the treatment of choice in closed diaphyseal tibial injuries. Removal of the nail is required in non-union, infected implant, implant failure or during exchange nailing procedure. Implant removal surgery presents some unique challenges to the Orthopaedic surgeons like broken nails, broken screws and failure of the extraction devices to engage with the threads of the nail due to stripping of the threads in the proximal part of the nail. Various techniques have been described by different authors to extract a broken distal piece of the nail. There are only a few articles described for the removal of an intramedullary nail when there is failure of the proximal extraction device. The failure of the proximal extraction device occurs due to the use of ill-fitting extraction bolts, cross threading and the presence of a very tight nail leading to stripping of the proximal threads. We describe a simple and novel technique with the use of the Stainless-Steel wire along with the extraction bolt when there is a failure of proximal extraction device for the extraction of cannulated or solid intramedullary nails.


Subject(s)
Bone Nails , Device Removal , Fracture Fixation, Intramedullary , Tibial Fractures , Adult , Humans , Male , Middle Aged , Device Removal/methods , Equipment Failure , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Tibial Fractures/surgery , Treatment Outcome
15.
Semin Dial ; 37(3): 273-276, 2024.
Article in English | MEDLINE | ID: mdl-38432229

ABSTRACT

Mechanical problems like break or crack in Luer connectors or hubs, clamps, and tubings are common non-infectious complications of tunneled dialysis catheters (TDC), which may lead to other TDC complications and the need to insert a new catheter. These can be tackled using TDC repair kits or spare parts, which are often not available, resulting in the insertion of a new TDC that increases morbidity, TDC-related procedures, and healthcare costs. We discuss two cases of broken Luer connections of TDC, which were managed by exchanging the broken Luer connector of TDC with the similar Luer connector of a temporary dialysis catheter. Both the repaired TDCs are thereafter functioning well. This improvised technique provides an easy, effective, long-lasting option that salvages the existing TDC and reduces the cost factor.


Subject(s)
Catheters, Indwelling , Equipment Failure , Renal Dialysis , Humans , Renal Dialysis/economics , Renal Dialysis/instrumentation , Catheters, Indwelling/adverse effects , Catheters, Indwelling/economics , Male , Kidney Failure, Chronic/therapy , Middle Aged , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/economics , Catheterization, Central Venous/instrumentation , Cost-Benefit Analysis , Female , Device Removal/methods , Device Removal/economics , Equipment Design
16.
J Cardiovasc Electrophysiol ; 35(5): 1050-1054, 2024 May.
Article in English | MEDLINE | ID: mdl-38501328

ABSTRACT

INTRODUCTION: Tricuspid regurgitation is associated with significant morbidity and mortality, and occurs at a higher rate in patients with cardiovascular implantable electronic devices. Percutaneous strategies for managing tricuspid regurgitation are evolving, including the development of bicaval valve implantation which has been successfully used in patients with pacing leads. METHODS AND RESULTS: We present the first documented case of lead failure following TricValve® implantation, a dedicated self-expanding system for bicaval valve implantation, and the first successful lead revision procedure in this setting. CONCLUSION: The case illustrates important considerations in undertaking percutaneous intervention in patients with cardiovascular implantable electronic devices, and their ongoing management.


Subject(s)
Defibrillators, Implantable , Equipment Failure , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/diagnostic imaging , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Male , Aged , Treatment Outcome , Reoperation , Prosthesis Design , Device Removal , Female , Electric Countershock/instrumentation , Electric Countershock/adverse effects
18.
Catheter Cardiovasc Interv ; 103(6): 1035-1041, 2024 May.
Article in English | MEDLINE | ID: mdl-38545668

ABSTRACT

A distinctive complication with balloon-expandable (BE) THV platforms such as the Edwards Sapien (Edwards Lifescience) is the possibility of balloon rupture during THV deployment. Balloon rupture is a rare occurrence that can result in stroke due to fragment embolism, incomplete THV expansion, and/or vascular injury upon retrieval of the balloon. Careful evaluation of preoperative computed tomography is essential to identify high-risk cases. While annular and left ventricular outflow tract (LVOT) calcification are widely acknowledged as common risks for balloon injury, it's essential to note that balloon injury can manifest at various anatomical sites. In this review, we discuss the mechanism behind balloon rupture, methods to identify cases at a heightened risk of balloon injury, approaches to mitigate the risk of rupture, and percutaneous retrieval strategies.


Subject(s)
Balloon Valvuloplasty , Equipment Failure , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Balloon Valvuloplasty/adverse effects , Balloon Valvuloplasty/instrumentation , Cardiac Catheters , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome
19.
J Vet Cardiol ; 52: 68-71, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38432142

ABSTRACT

A seven-year-old male castrated Labrador Retriever presented emergently due to concern for pacemaker malfunction five years after successful transvenous pacemaker implantation to treat partial atrial standstill. On presentation, the dog's pulse rate was 30-50 beats per minute. An electrocardiogram showed no spontaneous atrial activity or paced ventricular activity. Pacemaker interrogation revealed an increased impedance of 7557 ohms, indicating a lead malfunction. Thoracic radiographs confirmed the lead was fractured and had excessive coiling. The transvenous pacing system was turned off, left in place, and an epicardial pacing system was implanted the following day. The dog was discharged with no perioperative complications. The dog eventually required escalated medical therapy for progressive cardiac disease and was euthanized two years after implantation of the replacement pacemaker. This manuscript illustrates a complete lead fracture and excessive lead coiling, which has not previously been detailed in veterinary medicine.


Subject(s)
Dog Diseases , Equipment Failure , Pacemaker, Artificial , Dogs/injuries , Animals , Male , Pacemaker, Artificial/veterinary , Pacemaker, Artificial/adverse effects , Dog Diseases/therapy , Dog Diseases/diagnostic imaging , Equipment Failure/veterinary , Electrocardiography/veterinary
20.
Regul Toxicol Pharmacol ; 149: 105591, 2024 May.
Article in English | MEDLINE | ID: mdl-38467236

ABSTRACT

Post-market medical device-associated failures and patient problems are reported in Medical Device Reports (MDRs) to the US Food and Drug Administration. Reports are accessible through Manufacturer and User Facility Device Experience (MAUDE), a database including both required and voluntary submissions. We present an overview of >10 million MDRs received from 2011 to 2021. Approximately 92% of reporting issues represent medical device physical or functional failures, categorized from 1704 codes related to medical device integrity or function. ∼8% were coded adverse events (AEs). Patient outcomes are reported via 998 patient codes in 19 medical specialties (cardiovascular, orthopedic, etc.). ∼40% of patient reports indicated "no health consequences"; however, a small number of devices had consistently high AE reports. While overall reports did not exhibit a sex-based dichotomy, ∼9% of the reported AEs occurred more frequently in females, many of which were related to immune effects. The analyses are subject to uncertainties and potential bias based on data available and data selected for analysis. However, such an overview of post-market MDR data, not previously published, fills a gap in understanding medical device issues and patient-based outcomes related to medical device use. Trends identified may be subjects of additional hypotheses, analysis, and research.


Subject(s)
Equipment and Supplies , Product Surveillance, Postmarketing , United States Food and Drug Administration , Humans , Female , United States , Equipment and Supplies/adverse effects , Male , Databases, Factual , Sex Factors , Equipment Failure
SELECTION OF CITATIONS
SEARCH DETAIL
...