1.
Sci Rep ; 14(1): 10438, 2024 05 07.
Article in English | MEDLINE | ID: mdl-38714704

ABSTRACT

Thrombus formation in extracorporeal membrane oxygenation (ECMO) remains a major concern as it can lead to fatal outcomes. To the best of our knowledge, there is no standard non-invasive method for quantitatively measuring thrombi. This study's purpose was to verify thrombus detection in an ECMO circuit using novel, non-invasive ultrasonic sensors in real-time, utilizing the fact that the ultrasonic velocity in a thrombus is known to be higher than that in the blood. Ultrasonic sensors with a customized chamber, an ultrasonic pulse-receiver, and a digital storage oscilloscope (DSO) were used to set up the measuring unit. The customized chamber was connected to an ECMO circuit primed with porcine blood. Thrombi formed from static porcine blood were placed in the circuit and ultrasonic signals were extracted from the oscilloscope at various ECMO flow rates of 1-4 L/min. The ultrasonic signal changes were successfully detected at each flow rate on the DSO. The ultrasonic pulse signal shifted leftward when a thrombus passed between the two ultrasonic sensors and was easily detected on the DSO screen. This novel real-time non-invasive thrombus detection method may enable the early detection of floating thrombi in the ECMO system and early management of ECMO thrombi.


Subject(s)
Extracorporeal Membrane Oxygenation , Thrombosis , Extracorporeal Membrane Oxygenation/methods , Extracorporeal Membrane Oxygenation/instrumentation , Thrombosis/diagnostic imaging , Thrombosis/diagnosis , Animals , Swine , Ultrasonics , Ultrasonography/methods
2.
Int J Artif Organs ; 47(5): 347-355, 2024 May.
Article in English | MEDLINE | ID: mdl-38742758

ABSTRACT

BACKGROUND: Thrombosis within extracorporeal membrane oxygenation (ECMO) circuits is a common complication that dominates clinical management of patients receiving mechanical circulatory support. Prior studies have identified that over 80% of circuit thrombosis can be attributed to tubing-connector junctions. METHODS: A novel connector was designed that reduces local regions of flow stagnation at the tubing-connector junction to eliminate a primary source of ECMO circuit thrombi. To compare clotting between the novel connectors and the traditional connectors, both in vitro loops and an in vivo caprine model of long-term (48 h) ECMO were used to generate tubing-connector junction clots. RESULTS: In vitro, the traditional connectors uniformly (9/9) formed large thrombi, while novel connectors formed a small thrombus in only one of nine (p < 0.0001). In the long-term goat ECMO circuits, the traditional connectors exhibited more thrombi (p < 0.04), and these thrombi were more likely to protrude into the lumen of the tubing (p < 0.001). CONCLUSION: Both in vitro and in vivo validation experiments successfully recreated circuit thrombosis and demonstrate that the adoption of novel connectors can reduce the burden of circuit thrombosis.


Subject(s)
Equipment Design , Extracorporeal Membrane Oxygenation , Goats , Thrombosis , Extracorporeal Membrane Oxygenation/instrumentation , Animals , Thrombosis/etiology , Thrombosis/prevention & control , Disease Models, Animal , Blood Coagulation
3.
Comput Methods Programs Biomed ; 250: 108186, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38692252

ABSTRACT

BACKGROUND AND OBJECTIVES: Venovenous Extracorporeal Membrane Oxygenation (VV ECMO) provides respiratory support to patients with severe lung disease failing conventional medical therapy. An essential component of the ECMO circuit are the cannulas, which drain and return blood into the body. Despite being anchored to the patient to prevent accidental removal, minor cannula movements are common during ECMO. The clinical and haemodynamic consequences of these small movements are currently unclear. This study investigated the risk of thrombosis and recirculation caused by small movements of a dual lumen cannula (DLC) in an adult using computational fluid dynamics. METHODS: The 3D model of an AVALON Elite DLC (27 Fr) and a patient-specific vena cava and right atrium were generated for an adult patient on ECMO. The baseline cannula position was generated where the return jet enters the tricuspid valve. Alternative cannula positions were obtained by shifting the cannula 5 and 15 mm towards inferior (IVC) and superior (SVC) vena cava, respectively. ECMO settings of 4 L/min blood flow and pulsatile flow at SVC and IVC were applied. Recirculation was defined as a scalar value indicating the infused oxygenated blood inside the drainage lumen, while thrombosis risk was evaluated by shear stress, stagnation volume, washout, and turbulent kinetic energy. RESULTS: Recirculation for all models was less than 3.1 %. DLC movements between -5 to 15 mm increased shear stress and turbulence kinetic energy up to 24.7 % and 11.8 %, respectively, compared to the baseline cannula position leading to a higher predicted thrombosis risk. All models obtained a complete washout after nine seconds except for when the cannula migrated 15 mm into the SVC, indicating persisting stasis and circulating zones. CONCLUSION: In conclusion, small DLC movements were not associated with an increased risk of recirculation. However, they may increase the risk of thrombosis due to increased shear rate, turbulence, and slower washout of blood. Developing effective cannula securement devices may reduce this risk.


Subject(s)
Cannula , Extracorporeal Membrane Oxygenation , Hydrodynamics , Extracorporeal Membrane Oxygenation/instrumentation , Humans , Thrombosis/etiology , Thrombosis/prevention & control , Computer Simulation , Adult , Hemodynamics , Models, Cardiovascular
4.
ASAIO J ; 70(5): 377-386, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38324706

ABSTRACT

Extracorporeal membrane oxygenation (ECMO) is a temporary lifesaving treatment for critically ill patients with severe respiratory or cardiac failure. Studies demonstrated the feasibility of in-hospital mobilizing during and after ECMO treatment preventing neuromuscular weakness and impaired physical functioning. Despite more compact mobile ECMO devices, implementation of ambulatory ECMO remains labor-intensive, complex, and challenging. It requires a large multidisciplinary team to carry equipment, monitor and physically support the patient, and to provide a back-up wheelchair in case of fatigue. Moreover, there is no adequate solution to ensure the stability of the patient's cannula and circuit management during ambulation. We developed a system contributing to improvement and innovation of current ambulatory ECMO patient programs. Our modular cart-in-cart system carries necessary ECMO equipment, features an extendable walking frame, and contains a folding seat for patient transport. An adjustable shoulder brace with lockable tubing-connectors enables safe fixation of the blood tubing. ECMOve provides safety, support, and accessibility while performing ambulatory ECMO for both patient and caregiver. Prototype evaluation in a simulated intensive care unit showed feasibility of our design, but needs to be evaluated in clinical care.


Subject(s)
Extracorporeal Membrane Oxygenation , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/methods , Humans , Equipment Design , Critical Illness/therapy , Heart Failure/therapy
5.
Cardiovasc Revasc Med ; 62: 60-65, 2024 May.
Article in English | MEDLINE | ID: mdl-38184452

ABSTRACT

PURPOSE: Mechanical circulatory support (MCS) using a venoarterial extracorporeal membrane oxygenation (VA-ECMO) device or a catheter-type heart pump (Impella) is critical for the rescue of patients with severe cardiogenic shock. However, these MCS devices require large-bore cannula access (14-Fr and larger) at the femoral artery or vein, which often requires surgical decannulation. METHODS: In this retrospective study, we evaluated post-closure method using a percutaneous suture-mediated vascular closure system, Perclose ProGlide/ProStyle (Abbott Vascular, Lake Bluff, IL, Perclose), as an alternative procedure for MCS decannulation. Closure of 83 Impella access sites and 68 VA-ECMO access sites performed using Perclose or surgical method between January 2018 and March 2023 were evaluated. RESULTS: MCS decannulation using Perclose was successfully completed in all access sites without surgical hemostasis. The procedure time of ProGlide was shorter than surgical decannulation for both Impella and VA-ECMO (13 min vs. 50 min; p < 0.001, 21 min vs. 65 min; p < 0.001, respectively). There were no significant differences in the 30-day survival rate and major adverse events by decannulation including arterial dissection requiring endovascular treatment, hemorrhage requiring a large amount of red blood cell transfusion, and access site infection. CONCLUSION: Our results suggest that the post-closure technique using the percutaneous suture-mediated closure system appears to be a safe and effective method for large-bore MCS decannulation.


Subject(s)
Catheterization, Peripheral , Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Hemostatic Techniques , Punctures , Vascular Closure Devices , Humans , Retrospective Studies , Male , Female , Treatment Outcome , Middle Aged , Aged , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/instrumentation , Time Factors , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Device Removal/adverse effects , Suture Techniques/instrumentation , Suture Techniques/adverse effects , Femoral Artery , Shock, Cardiogenic/therapy , Shock, Cardiogenic/mortality , Shock, Cardiogenic/physiopathology , Shock, Cardiogenic/diagnosis , Risk Factors , Hemorrhage/etiology , Hemorrhage/prevention & control
6.
ASAIO J ; 70(6): 535-544, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38165978

ABSTRACT

Microfluidic membrane oxygenators are designed to mimic branching vasculature of the native lung during extracorporeal lung support. To date, scaling of such devices to achieve clinically relevant blood flow and lung support has been a limitation. We evaluated a novel multilayer microfluidic blood oxygenator (BLOx) capable of supporting 750-800 ml/min blood flow versus a standard hollow fiber membrane oxygenator (HFMO) in vivo during veno-venous extracorporeal life support for 24 hours in anesthetized, mechanically ventilated uninjured swine (n = 3/group). The objective was to assess feasibility, safety, and biocompatibility. Circuits remained patent and operated with stable pressures throughout 24 hours. No group differences in vital signs or evidence of end-organ damage occurred. No change in plasma free hemoglobin and von Willebrand factor multimer size distribution were observed. Platelet count decreased in BLOx at 6 hours (37% dec, P = 0.03), but not in HFMO; however, thrombin generation potential was elevated in HFMO (596 ± 81 nM·min) versus BLOx (323 ± 39 nM·min) at 24 hours ( P = 0.04). Other coagulation and inflammatory mediator results were unremarkable. BLOx required higher mechanical ventilator settings and showed lower gas transfer efficiency versus HFMO, but the stable device performance indicates that this technology is ready for further performance scaling and testing in lung injury models and during longer use conditions.


Subject(s)
Feasibility Studies , Oxygenators, Membrane , Animals , Swine , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/methods , Extracorporeal Membrane Oxygenation/adverse effects , Intensive Care Units , Microfluidics/methods , Microfluidics/instrumentation
7.
Comput Biol Med ; 159: 106907, 2023 06.
Article in English | MEDLINE | ID: mdl-37075599

ABSTRACT

PURPOSE: The geometric structure of the membrane oxygenator can exert an impact on its hemodynamic features, which contribute to the development of thrombosis, thereby affecting the clinical efficacy of ECMO treatment. The purpose of this study is to investigate the impact of varying geometric structures on hemodynamic features and thrombosis risk of membrane oxygenators with different designs. METHODS: Five oxygenator models with different structures, including different number and location of blood inlet and outlet, as well as variations in blood flow path, were established for investigation. These models are referred to as Model 1 (Quadrox-i Adult Oxygenator), Model 2 (HLS Module Advanced 7.0 Oxygenator), Model 3 (Nautilus ECMO Oxygenator), Model 4 (OxiaACF Oxygenator) and Model 5 (New design oxygenator). The hemodynamic features of these models were numerically analyzed using the Euler method combined with computational fluid dynamics (CFD). The accumulated residence time (ART) and coagulation factor concentrations (C[i], where i represents different coagulation factors) were calculated by solving the convection diffusion equation. The resulting relationships between these factors and the development of thrombosis in the oxygenator were then investigated. RESULTS: Our results show that the geometric structure of the membrane oxygenator, including the location of the blood inlet and outlet as well as the design of the flow path, has a significant impact on the hemodynamic surroundings within the oxygenator. In comparison to Model 4, which had the inlet and outlet located in the center position, Model 1 and Model 3, which had the inlet and outlet at the edge of the blood flow field, exhibited a more uneven distribution of blood flow within the oxygenator, particularly in areas distant from the inlet and outlet, which was accompanied with lower flow velocity and higher values of ART and C[i], leading to the formation of flow dead zones and an elevated risk of thrombosis. The oxygenator of Model 5 is designed with a structure that features multiple inlets and outlets, which greatly improves the hemodynamic environment inside the oxygenator. This results in a more even distribution of blood flow within the oxygenator, reducing areas with high values of ART and C[i], and ultimately lowering the risk of thrombosis. The oxygenator of Model 3 with circular flow path section shows better hemodynamic performance compared to the oxygenator of Model 1 with square circular flow path. The overall ranking of hemodynamic performance for all five oxygenators is as follows: Model 5 > Model 4 > Model 2 > Model 3 > Model 1, indicating that Model 1 has the highest thrombosis risk while Model 5 has the lowest. CONCLUSION: The study reveals that the different structures can affect the hemodynamic characteristics inside membrane oxygenators. The design of multiple inlets and outlets can improve the hemodynamic performance and reduce the thrombosis risk in membrane oxygenators. These findings of this study can be used to guide the optimization design of membrane oxygenators for improving hemodynamic surroundings and reducing thrombosis risk.


Subject(s)
Extracorporeal Membrane Oxygenation , Hemodynamics , Oxygenators, Membrane , Thrombosis , Thrombosis/etiology , Oxygenators, Membrane/adverse effects , Oxygenators, Membrane/classification , Equipment Design , Extracorporeal Membrane Oxygenation/instrumentation , Humans , Computer Simulation
8.
JAMA ; 329(19): 1693-1694, 2023 05 16.
Article in English | MEDLINE | ID: mdl-37103942

ABSTRACT

This JAMA Insights Clinical Update discusses the newer treatment option of extracorporeal cardiopulmonary resuscitation, particularly for patients with cardiac arrest who are not responsive to initial treatment.


Subject(s)
Cardiopulmonary Resuscitation , Extracorporeal Membrane Oxygenation , Heart Arrest , Humans , Cardiopulmonary Resuscitation/instrumentation , Cardiopulmonary Resuscitation/methods , Heart Arrest/therapy , Out-of-Hospital Cardiac Arrest/therapy , Treatment Outcome , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/methods
9.
ASAIO J ; 68(8): 1017-1023, 2022 08 01.
Article in English | MEDLINE | ID: mdl-35617687

ABSTRACT

Coronavirus disease 2019 (COVID-19) has drastically increased the number of patients requiring extracorporeal life support. We investigate the efficacy and safety of low-dose recombinant tissue-type plasminogen activator (rtPA) injection into exhausted oxygenators to delay exchange in critically ill COVID-19 patients on veno-venous extracorporeal membrane oxygenation (V-V ECMO). Small doses of rtPA were injected directly into the draining section of a V-V ECMO circuit. We compared transmembrane pressure gradient, pump head efficiency, membrane arterial partial oxygen pressure, and membrane arterial partial carbon dioxide pressure before and after the procedure. Bleeding was compared with a matched control group of 20 COVID-19 patients on V-V ECMO receiving standard anticoagulation. Four patients received 16 oxygenator instillations with rtPA at 5, 10, or 20 mg per dose. Administration of rtPA significantly reduced transmembrane pressure gradient (Δ pm = 54.8 ± 18.1 mmHg before vs . 38.3 ± 13.3 mmHg after, p < 0.001) in a dose-dependent manner (Pearson's R -0.63, p = 0.023), allowing to delay oxygenator exchange, thus reducing the overall number of consumed oxygenators. rtPA increased blood flow efficiency η (1.20 ± 0.28 ml/revolution before vs . 1.24 ± 0.27 ml/r, p = 0.002). Lysis did not affect membrane blood gases or systemic coagulation. Minor bleeding occurred in 2 of 4 patients (50%) receiving oxygenator lysis as well as 19 of 20 control patients (95%). Lysis of ECMO oxygenators effectively delays oxygenator exchange, if exchange is indicated by an increase in transmembrane pressure gradient. Application of lysis did not result in higher bleeding incidences compared with anticoagulated patients on V-V ECMO for COVID-19.


Subject(s)
COVID-19 Drug Treatment , Extracorporeal Membrane Oxygenation , Oxygenators, Membrane , Tissue Plasminogen Activator , Blood Gas Analysis , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/methods , Humans , Tissue Plasminogen Activator/therapeutic use
10.
Ann Thorac Surg ; 114(3): 1050-1054, 2022 09.
Article in English | MEDLINE | ID: mdl-35504359

ABSTRACT

PURPOSE: Dual-lumen extracorporeal membrane oxygenation (ECMO) cannulation is considered technically challenging and harbors the risk of potential life-threatening complications during cannulation. Dual-lumen cannula insertion is performed under either ultrasound or fluoroscopy guidance. Both techniques have significant disadvantages, such as examiner dependence or the necessity for transportation of the patient from the intensive care unit to the operating room. DESCRIPTION: Digital, mobile x-ray devices provide a novel, examiner-independent imaging modality for bedside dual-lumen ECMO cannulation. EVALUATION: From November 2019 to November 2021, 23 dual-lumen cannulations were performed in 20 patients at the Department of Thoracic Surgery, Medical University of Vienna. Twelve of 23 (52.2%) were inserted in the intensive care unit using a mobile x-ray device. The remaining patients (47.8%) were cannulated in the operating room with conventional fluoroscopy guidance. In none of the procedures did cardiovascular injuries occur. Insertion site bleeding was the most common ECMO-related complication (n = 2). CONCLUSIONS: Dual-lumen cannulation using sequential x-rays can be performed safely. Especially for infectious patients or patients who require an awake ECMO, this technique overcomes disadvantages of established imaging modalities.


Subject(s)
Catheterization , Extracorporeal Membrane Oxygenation , X-Rays , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/methods , Humans , Retrospective Studies , Ultrasonography
11.
BMC Cardiovasc Disord ; 22(1): 54, 2022 02 16.
Article in English | MEDLINE | ID: mdl-35172726

ABSTRACT

BACKGROUND: Extracorporeal left ventricular assist device is often required for acute myocardial infarction patients in cardiogenic shock when temporary mechanical circulatory support fails to provide hemodynamic stabilization. This study aimed to evaluate the clinical outcomes of acute myocardial infarction patients in cardiogenic shock supported by an extracorporeal left ventricular assist device. METHODS: This retrospective study enrolled 13 acute myocardial infarction patients in cardiogenic shock treated with an extracorporeal left ventricular assist device from April 2011 to July 2020. RESULTS: Twelve (92.3%) and eleven (84.6%) patients were supported using venoarterial extracorporeal membrane oxygenation and intra-aortic balloon pumping before implantation, respectively. The median duration from acute myocardial infarction to extracorporeal left ventricular assist device implantation was 7 (3.5-24.5) days. The overall in-hospital mortality rate was 30.8% (n = 4). Extracorporeal left ventricular assist device was explanted in one patient for cardiac recovery; eight (61.5%) patients were approved as heart transplant candidates in whom the extracorporeal left ventricular assist device was exchanged for a durable left ventricular assist device; two (15.4%) expired while waiting for a heart transplant, and two (15.4%) received a successful transplant. The 1- and 3-year overall survival rates after extracorporeal left ventricular assist device implantation were 68.3% and 49.9%, respectively. CONCLUSIONS: The operative mortality after extracorporeal left ventricular assist device implantation in acute myocardial infarction patients in cardiogenic shock was favorable. Our strategy of early hemodynamic stabilization with extracorporeal left ventricular assist device implantation in these patients as a bridge-to-bridge therapy was effective in achieving better survival.


Subject(s)
Extracorporeal Membrane Oxygenation/instrumentation , Heart Transplantation , Heart-Assist Devices , Hemodynamics , Myocardial Infarction/surgery , Shock, Cardiogenic/surgery , Ventricular Function, Left , Waiting Lists , Adolescent , Adult , Device Removal , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/mortality , Female , Hospital Mortality , Humans , Male , Middle Aged , Myocardial Infarction/diagnosis , Myocardial Infarction/mortality , Myocardial Infarction/physiopathology , Prosthesis Design , Recovery of Function , Retrospective Studies , Shock, Cardiogenic/diagnosis , Shock, Cardiogenic/mortality , Shock, Cardiogenic/physiopathology , Time Factors , Time-to-Treatment , Treatment Outcome , Waiting Lists/mortality , Young Adult
12.
Sci Rep ; 12(1): 1265, 2022 01 24.
Article in English | MEDLINE | ID: mdl-35075252

ABSTRACT

To identify predictors of neonatal ECMO circuit health, a retrospective analysis of circuit functional pressure and flow parameters as well as infant clotting values were collected 48 h prior to and 24 h post circuit change. Circuit impairment was defined as need for partial or total circuit change. Statistical analysis used multivariate statistics and non-parametric Mann-Whitney U-test with possible non-normality of measurements. A total of 9764 ECMO circuit and clotting values in 21 circuits were analyzed. Circuit delta-P mean, and maximum values increased from 8.62 to 48.59 mmHg (p < 0.011) and 16.00 to 53.00 mmHg (p < 0.0128) respectively prior to need for circuit change. Maximum and mean Pump Flow Revolutions per minute (RPM) increased by 75% (p < 0.0043) and 81% (p < 0.0057), respectively. Mean plasma free hemoglobin (pfHb) increased from 26.45 to 76.00 mg/dl, (p < 0.0209). Sweep, venous pressure, and clotting parameters were unaffected. ECMO circuit delta-P, RPM, and pfHb were early predictors of circuit impairment.


Subject(s)
Extracorporeal Membrane Oxygenation/instrumentation , Blood Coagulation Tests , Extracorporeal Membrane Oxygenation/statistics & numerical data , Female , Humans , Infant, Newborn , Male , Platelet Count , Retrospective Studies
13.
Circ Heart Fail ; 15(1): e008777, 2022 01.
Article in English | MEDLINE | ID: mdl-34879706

ABSTRACT

BACKGROUND: There has been increasing use of extracorporeal membrane oxygenation (ECMO) as bridge to heart transplant (orthotopic heart transplant [OHT]) or left ventricular assist device (LVAD) over the last decade. We aimed to provide insights on the population, outcomes, and predictors for the selection of each therapy. METHODS: Using the Extracorporeal Life Support Organization Registry between 2010 and 2019, we compared in-hospital mortality and length of stay, predictors of OHT versus LVAD, and predictors of in-hospital mortality for patients with cardiogenic shock that were bridged with ECMO to OHT or LVAD. One hundred sixty-seven patients underwent LVAD versus 234 patients who underwent OHT. RESULTS: The overall use of ECMO has increased from 1.7% in 2010 to 22.2% in 2019. Mortality was similar between groups (LVAD: 28.7% versus OHT: 29.1%) while length of stay was longer for OHT (LVAD: 49.6 versus OHT: 59.5 days, P=0.05). Factors associated with OHT included prior transplant (odds ratio [OR]=31.26 [CI, 3.84-780.5]), use of a temporary pacemaker (OR=6.5 [CI, 1.39-50.15]), and increased use of inotropes on ECMO (OR=3.77 [CI, 1.39-11.07]), whereas LVAD use was associated with weight (OR=0.98 [CI, 0.97-0.99]), cardiogenic shock presentation (OR=0.40 [CI, 0.21-0.78]), previous LVAD (OR=0.01 [CI, 0.0001-0.22]), respiratory failure (OR=0.28 [CI, 0.11-0.70]), and milrinone infusion (OR=0.32 [CI, 0.15-0.67]). Older age (OR=1.07 [CI, 1.02-1.12]), cannulation bleeding (OR=26.1 [CI, 4.32-221.3]), and surgical bleeding (OR=6.7 [CI, 1.26-39.9]) in patients receiving LVAD and respiratory failure (OR=5 [CI, 1.17-23.1]) and continuous renal replacement therapy (OR=3.82 [CI, 1.28-11.9]) in patients receiving OHT were associated with increased mortality. CONCLUSIONS: ECMO use as a bridge to advanced therapies has increased over time, with more patients undergoing LVAD than OHT. Mortality was equal between the 2 groups while length of stay was longer for OHT.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart Failure/therapy , Heart-Assist Devices/adverse effects , Shock, Cardiogenic/therapy , Adolescent , Adult , Aged , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/methods , Female , Heart Transplantation/methods , Hospital Mortality , Humans , Male , Middle Aged , Registries/statistics & numerical data , Young Adult
14.
Surg Clin North Am ; 102(1): 23-35, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34800387

ABSTRACT

OVERVIEW: The use of extracorporeal membrane oxygenation (ECMO) is becoming commonplace worldwide in ICUs for the care of patients with respiratory and/or cardiac failure. Understanding the use of ECMO and the management of these complex patients will be vital to current and future clinicians as ECMO use continues to grow.


Subject(s)
Extracorporeal Membrane Oxygenation/methods , Cannula , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/instrumentation , Humans , Patient Selection , Respiration, Artificial
15.
Ann Biomed Eng ; 49(12): 3636-3646, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34705123

ABSTRACT

Oxygenator thrombosis during extracorporeal membrane oxygenation (ECMO), is a complication that necessitates component replacement. ECMO centers monitor clot burden by intermittent measurement of pressure drop across the oxygenator. An increase in pressure drop at a preset flow rate suggests an increase in resistance/clot formation within the oxygenator. This monitoring method comes with inherent disadvantages such as monitoring gaps, and increased risk of air embolism and infection. We explored utilizing flow measurement, which avoids such risks, as an indicator of ECMO circuit obstructions. The hypothesis that flow rate through a shunt tube in the circuit will increase as distal resistances in the circuit increases was tested. We experimentally simulated controlled levels of oxygenator obstructions using glass microspheres in an ex vivo veno-venous ECMO circuit and measured the change in shunt flow rate using over the tube ultra-sound flow probes. A mathematical model was also used to study the effect of distal resistances in the ECMO circuit on shunt flow. Results of both the mathematical model and the experiments showed a clear and measurable increase in shunt flow with increasing levels of oxygenator obstruction. Therefore, flow monitoring appears to be an effective non-contact and continuous method to monitor for obstruction during ECMO.


Subject(s)
Extracorporeal Membrane Oxygenation/instrumentation , Oxygenators, Membrane , Blood Circulation , Equipment Failure , Extracorporeal Membrane Oxygenation/adverse effects , Humans , Models, Statistical , Oxygen/blood
16.
PLoS One ; 16(9): e0257449, 2021.
Article in English | MEDLINE | ID: mdl-34529734

ABSTRACT

Despite the formation of biofilms on catheters for extracorporeal membrane oxygenation (ECMO), some patients do not show bacteremia. To elucidate the specific linkage between biofilms and bacteremia in patients with ECMO, an improved understanding of the microbial community within catheter biofilms is necessary. Hence, we aimed to evaluate the biofilm microbiome of ECMO catheters from adults with (n = 6) and without (n = 15) bacteremia. The microbiomes of the catheter biofilms were evaluated by profiling the V3 and V4 regions of bacterial 16s rRNA genes using the Illumina MiSeq sequencing platform. In total, 2,548,172 reads, with an average of 121,341 reads per sample, were generated. Although alpha diversity was slightly higher in the non-bacteremic group, the difference was not statistically significant. In addition, there was no difference in beta diversity between the two groups. We found 367 different genera, of which 8 were present in all samples regardless of group; Limnohabitans, Flavobacterium, Delftia, Massilia, Bacillus, Candidatus, Xiphinematobacter, and CL0-1 showed an abundance of more than 1% in the sample. In particular, Arthrobacter, SMB53, Neisseria, Ortrobactrum, Candidatus Rhabdochlamydia, Deefgae, Dyella, Paracoccus, and Pedobacter were highly abundant in the bacteremic group. Network analysis indicated that the microbiome of the bacteremic group was more complex than that of the non-bacteremic group. Flavobacterium and CL0.1, which were abundant in the bacteremic group, were considered important genera because they connected different subnetworks. Biofilm characteristics in ECMO catheters varied according to the presence or absence of bacteremia. There were no significant differences in diversity between the two groups, but there were significant differences in the community composition of the biofilms. The biofilm-associated community was dynamic, with the bacteremic group showing very complex network connections within the microbiome.


Subject(s)
Bacteremia/microbiology , Catheter-Related Infections/microbiology , Extracorporeal Membrane Oxygenation/instrumentation , Microbiota , Arthrobacter/genetics , Arthrobacter/isolation & purification , Arthrobacter/physiology , Bacteremia/pathology , Bacteria/genetics , Bacteria/isolation & purification , Biofilms , Catheter-Related Infections/pathology , Female , Humans , Male , Middle Aged , Neisseria/genetics , Neisseria/isolation & purification , Neisseria/physiology , RNA, Ribosomal, 16S/analysis , RNA, Ribosomal, 16S/genetics , RNA, Ribosomal, 16S/metabolism , Retrospective Studies
17.
Circ Heart Fail ; 14(7): e007679, 2021 07.
Article in English | MEDLINE | ID: mdl-34247519

ABSTRACT

Venoarterial extracorporeal membrane oxygenation may be used for circulatory support in cardiogenic shock as a bridge to recovery, a bridge to a ventricular assist device (VAD), or a bridge to transplant. While the determination of potential exit strategies is essential before cannulation, the final determination of a patient's options may change, in part, through their in-hospital clinical course. We propose that liberation from venoarterial extracorporeal membrane oxygenation should be conceptualized as a process of discovery in the assessment of a patient's underlying clinical status and a key driver of further clinical decision-making. A trial of liberation from support should be considered when the goals of the weaning trial are well-defined and, ideally, in the absence of potentially confounding clinical factors. In this review, we will discuss readiness to wean criteria from venoarterial extracorporeal membrane oxygenation, as well as specific clinical, biochemical, and echocardiographic parameters that may prove useful in determining weaning timing and revealing the patient's underlying hemodynamic status and prognosis. The role of various cannula configurations, support devices, and pharmacological adjuncts will also be discussed. Finally, we highlight current gaps in evidence and suggest areas of future research.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart Failure/etiology , Heart-Assist Devices/adverse effects , Shock, Cardiogenic/physiopathology , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/methods , Hemodynamics/physiology , Humans , Risk Factors , Shock, Cardiogenic/therapy
18.
Brasília; CONITEC; jun. 2021.
Non-conventional in Portuguese | BRISA/RedTESA | ID: biblio-1293256

ABSTRACT

INTRODUÇÃO: Na atualidade, com a pandemia pelo novo Coronavírus, SARS-CoV-2, 15% dos casos (> 2 milhões) tem sido documentados e hospitalizados. Dentre estes pacientes internados, >50% tiveram requerimento de cuidados intensivos, e em UTI, ≈80% dos casos necessitaram/ necessitam ventilação mecânica invasiva, VMi. Quando refratários à VM, um certo número de pacientes, sobretudo mais jovens sem ou com apenas 1 comorbidade, têm se beneficiado de suporte com a ECMO. TECNOLOGIA: Oxigenação por membrana extracorpórea (ECMO). PERGUNTA: A oxigenação por membrana extracorpórea (ECMO) possui efetividade em reduzir complicações e mortalidade ou em melhorar a qualidade de vida dos pacientes com síndrome respiratória aguda grave decorrente de infecções virais, refratária à ventilação mecânica convencional em comparação às alternativas terapêuticas para o tratamento da ventilação mecânica convencional isolada? Qual é a relação entre o custo da ECMO e sua efetividade comparativa? Qual seria a estimativa de impacto orçamentário deste procedimento para o SUS? EVIDÊNCIAS CLÍNICAS: A revisão sistemática comparando o suporte respiratório com ventilação mecânica em pacientes com SARA grave versus ventilação mecânica ultra - protetora associada à ECMO foi realizada com seis estudos, 915 pacientes nos 3 estudos randomizados com alta qualidade e 3 com pareamento caso-controle estruturado e baixo risco de vieses, exceto 1 mais antigo que apresentou elevado risco de viés de publicação. A metanálise combinando os estudos (com baixa heterogeneidade I2=9%, p=0,35) mostrou um ganho consistente de 33% de sobrevida (RR=0,67; IC95%: 0,57 a 0,79) para os pacientes com SRAG ou SARA grave que receberam suporte com ECMO, tanto no modelo fixo quanto no modelo de efeitos aleatórios. Também houve tendência de vantagem na qualidade de vida em favor da ECMO nos aspectos de saúde em geral em 1 destes estudos. As complicações como sangramento, isquemia de extremidades, hemólise e ativação da resposta inflamatória se reduziram com a associação com a estratégia ventilatória protetora com baixos volumes correntes e baixas pressões em vias aéreas permitindo o mais amplo uso de ECMO VV e repouso pulmonar (RR= 2,81; IC95%: 0,4 a 19,89 em 3 estudos que as relataram). A taxa de mortalidade em pacientes com COVID-19 foi de 87,5% nos pacientes com ECMO e 69,2% nos pacientes com terapia convencional. As chances combinadas de mortalidade em ECMO comparada à terapia convencional não foram significativamente diferentes (Estimativa= 0,273, IC95%, 0,06 a 1,111; I2= 0%, Q de Cochran, valor de p= 0,57). AVALIAÇÃO ECONÔMICA: Avaliação econômica: Na experiência Brasileira com a pandemia de COVID-19, a estimativa de custo da internação com a ventilação mecânica foi de R$ 78.750,34 para ganhar 0,222±0,024 QALY versus R$ 119.433,62 com a ECMO para se obter 0,646±0,066 QALYs, resultando na diferença incremental de R$ 40.683,28/0,424±0,042 QALYs e na relação de custo-efetividade incremental, RCEI, de valor de R$ 95.951,13 para se obter 1 ano de vida ganho com qualidade. A Análise de Sensibilidade, variando os dias de ocorrência dos eventos segundo os limites do IC95%, resultou no mínimo valor da internação de R$ 37.206,15 devido aos óbitos precoces sob VM até o máximo de R$ 359.504,63 em casos de fatalidades em pacientes com comorbidade e permanência prolongada; em 1% dos pacientes que tiveram suporte com ECMO o custo variou entre no mínimo R$ 100.955,12 (adicionando R$ 7.448,27 ao conjunto das terapias) até o máximo de R$ 309.801,16, casos em que reduziu a permanência em pacientes com comorbidade e reduziu os custos de R$ 11.000,19 para o conjunto das terapias. ANÁLISE DE IMPACTO ORÇAMENTÁRIO: Internacionalmente, a necessidade de ECMO está estimada em 1% a 1,2% dos pacientes com SARA grave que estão sob ventilação mecânica invasiva. Desta forma, 99% dos pacientes críticos com COVID-19 responderiam com ventilação mecânica convencional e o restante 1% refratário necessitaria resgate ECMO. Para o Brasil, o Impacto Orçamentário Incremental com a intervenção de ECMO somaria R$ 15.703.746,08 no 1º. ano e se estima somar R$ 80.816.036,09 com uma taxa de 1% de desconto nos 5 primeiros anos. CONSIDERAÇÕES FINAIS: ECMO com indicações cuidadosas pode resgatar uma parcela 1% dos pacientes (≈ 400) e recuperar de morte evitável, sobretudo, como parte da Política Nacional de Emergency Preparedness, mediante impacto orçamentário de R$ 15 milhões. Em 2020, 1% das internações COVID-19 foram extremamente prolongadas sob ventilação mecânica exclusiva, que além das fatalidades, custaram mais que a adoção deste programa. Aprimorar a rede nacional contribui para o planejamento do sistema de saúde, justifica investimentos públicos e favorece o cumprimento das metas de desenvolvimento comprometidas internacionalmente, bem como a classificação do Brasil pela OMS. A adoção deste procedimento de alto custo e alta complexidade pelo SUS certamente favorecerá, como nas experiências internacionais citadas acima, negociar e regular o mercado para evitar abusos, bem como complementar a Política Nacional de Emergency Preparedness para esta e outras emergências de insuficiência respiratória aguda e refratária à ventilação mecânica, onde o suporte ao pulmão e coração auxilie a prevenir morte evitável. RECOMENDAÇÃO INICIAL DA CONITEC: A matéria foi pautada na 5ª Reunião Extraordinária da Conitec no dia 13 de maio de 2021. Os membros da Conitec entenderam que apesar dos benefícios do tratamento, há uma grande dificuldade de ampliação e cobertura de tratamento para todos os pacientes que porventura iriam necessitar da terapia. O plenário pontuou que de 30 equipes e centros reconhecidos e cadastrados na ELSO que oferecem o suporte com ECMO, apenas nove são pertencentes ao Sistema Único de Saúde (SUS), sendo a maioria deles concentrados em grandes centros na região Sudeste. Assim, os membros presentes entenderam que haveria uma inequidade no atendimento à população em tratamento no SUS devido à concentração de equipe especializada em uma região e dificuldades de transferência destes pacientes para esses grandes centros. Foi pontuado também, a impossibilidade de tratamento com ECMO em hospitais de campanha devido ao alto investimento em infraestrutura e ausência de pessoal qualificado para condução do paciente. Atendendo ao SUS, há apenas dois centros que possuem nível de 30 experiências anteriores com tratamento e certificação ELSO. Para certificação cada centro precisa ter realizado pelo menos cinco procedimentos supervisionados para se qualificar e certificar, portanto, inviável a criação de novos centros no contexto atual. E por fim, apenas uma pequena parcela da população necessitaria do procedimento. Pelo exposto, o Plenário deliberou que a matéria fosse disponibilizada em Consulta Pública com recomendação preliminar desfavorável à incorporação da oxigenação por membrana extracorpórea (ECMO) para o suporte de pacientes com síndrome respiratória aguda grave decorrente de infecções virais, refratária à ventilação mecânica convencional no âmbito do SUS. CONSULTA PÚBLICA: A Consulta Pública nº 38 foi realizada entre os dias 17/05/2021 e 27/05/2021 e apresentada na 98ª. Reunião em 10 de junho de 2021. Nesta, foram recebidas 212 contribuições, sendo 72 pelo formulário para contribuições técnico-científicas e 140 pelo formulário para contribuições sobre experiência ou opinião de pacientes, familiares, amigos ou cuidadores de pacientes, profissionais de saúde ou pessoas interessadas no tema. No total, dentre as 72 Contribuições técnico-científicas, 42 foram não vazias: 3 Contribuições Concordantes com parecer desfavorável à incorporação, 1 para uma medicação e 38 Contribuições Discordantes com a recomendação preliminar membros da Conitec desfavorável à incorporação da ECMO. No formulário sobre experiência ou opinião, em total, houve 140 Contribuições com 86 substantivas sendo 3 Contribuições Concordantes com parecer desfavorável à incorporação, 1 para outra tecnologia e 83 Contribuições Discordantes com a recomendação preliminar membros da Conitec desfavorável à incorporação da ECMO. A Consulta Pública contou, portanto, com 60% de contribuições não vazias (127 dentre as 212) sendo majoritariamente (93%) em favor da incorporação da Oxigenação Extracorpórea (ECMO) como terapia para suporte de pacientes com insuficiência respiratória grave e refratária e prevenir mortes evitáveis. RECOMENDAÇÃO FINAL DA CONITEC: Pelo exposto, o Plenário da Conitec, em sua 98ª Reunião Ordinária, no dia 10 de junho de 2021, deliberou por maioria simples recomendar a não incorporação da Oxigenação Extracorpórea (ECMO) como terapia para suporte de pacientes com insuficiência respiratória grave e refratária no SUS. Para tomar essa decisão, os membros do Plenário da Conitec consideraram que apesar dos benefícios do tratamento, há uma grande dificuldade de ampliação e cobertura de tratamento para todos os pacientes que porventura iriam necessitar da terapia, e que seria inviável a criação de novos centros no contexto atual. Por fim, foi assinado o Registro de Deliberação no . 631/2021. DECISÃO: Não incorporar a Oxigenação por Membrana Extracorpórea (ECMO) para o suporte de pacientes com insuficiência respiratória grave e refratária, no âmbito do Sistema Único de Saúde ­ SUS, conforme a Portaria nº 1.327, publicada no Diário Oficial da União nº 118, seção 1, página 128, em 25 de junho de 2021.


Subject(s)
Humans , Respiratory Insufficiency/therapy , Extracorporeal Membrane Oxygenation/instrumentation , Respiration, Artificial/adverse effects , Unified Health System , Brazil , Cost-Benefit Analysis
19.
Isr Med Assoc J ; 23(5): 274-278, 2021 May.
Article in English | MEDLINE | ID: mdl-34024042

ABSTRACT

BACKGROUND: This focus article is a theoretical reflection on the ethics of allocating respirators to patients in circumstances of shortage, especially during the coronavirus disease-2019 (COVID-19) outbreak in Israel. In this article, respirators are placeholders for similar life-saving modalities in short supply, such as extracorporeal membrane oxygenation machines and intensive care unit beds. In the article, I propose a system of triage for circumstances of scarcity of respirators. The system separates the hopeless from the curable, granting every treatable person a real chance of cure. The scarcity situation eliminates excesses of medicine, and then allocates respirators by a single scale, combining an evidence-based scoring system with risk-proportionate lottery. The triage proposed embodies continuity and consistency with the healthcare practices in ordinary times. Yet, I suggest two regulatory modifications: one in relation to expediting review of novel and makeshift solutions and the second in relation to mandatory retrospective research on all relevant medical data and standard (as opposed to experimental) interventions that are influenced by the triage.


Subject(s)
COVID-19/therapy , Resource Allocation/ethics , Triage/methods , Ventilators, Mechanical/supply & distribution , COVID-19/epidemiology , Disease Outbreaks , Ethical Analysis , Extracorporeal Membrane Oxygenation/instrumentation , Humans , Intensive Care Units/ethics , Intensive Care Units/supply & distribution , Israel , Triage/ethics , Ventilators, Mechanical/ethics
20.
Crit Care ; 25(1): 174, 2021 05 22.
Article in English | MEDLINE | ID: mdl-34022934

ABSTRACT

BACKGROUND: Mechanical circulatory support (MCS) with either extracorporeal membrane oxygenation or Impella has shown potential as a salvage therapy for patients with refractory out-of-hospital cardiac arrest (OHCA). The objective of this study was to describe the gradual implementation, survival and adherence to the national consensus with respect to use of MCS for OHCA in Denmark, and to identify factors associated with outcome. METHODS: This retrospective, observational cohort study included patients receiving MCS for OHCA at all tertiary cardiac arrest centers (n = 4) in Denmark between July 2011 and December 2020. Logistic regression and Kaplan-Meier survival analysis were used to determine association with outcome. Outcome was presented as survival to hospital discharge with good neurological outcome, 30-day survival and predictors of 30-day mortality. RESULTS: A total of 259 patients were included in the study. Thirty-day survival was 26%. Sixty-five (25%) survived to hospital discharge and a good neurological outcome (Glasgow-Pittsburgh Cerebral Performance Categories 1-2) was observed in 94% of these patients. Strict adherence to the national consensus showed a 30-day survival rate of 30% compared with 22% in patients violating one or more criteria. Adding criteria to the national consensus such as signs of life during cardiopulmonary resuscitation (CPR), pre-hospital low-flow < 100 min, pH > 6.8 and lactate < 15 mmol/L increased the survival rate to 48%, but would exclude 58% of the survivors from the current cohort. Logistic regression identified asystole (RR 1.36, 95% CI 1.18-1.57), pulseless electrical activity (RR 1.20, 95% CI 1.03-1.41), initial pH < 6.8 (RR 1.28, 95% CI 1.12-1.46) and lactate levels > 15 mmol/L (RR 1.16, 95% CI 1.16-1.53) as factors associated with increased risk of 30-day mortality. Patients presenting signs of life during CPR had reduced risk of 30-day mortality (RR 0.63, 95% CI 0.52-0.76). CONCLUSIONS: A high survival rate with a good neurological outcome was observed in this Danish population of patients treated with MCS for OHCA. Stringent patient selection for MCS may produce higher survival rates but potentially withholds life-saving treatment in a significant proportion of survivors.


Subject(s)
Extracorporeal Membrane Oxygenation/instrumentation , Out-of-Hospital Cardiac Arrest/therapy , Aged , Aged, 80 and over , Cohort Studies , Denmark/epidemiology , Extracorporeal Membrane Oxygenation/methods , Extracorporeal Membrane Oxygenation/statistics & numerical data , Female , Humans , Kaplan-Meier Estimate , Logistic Models , Male , Middle Aged , Out-of-Hospital Cardiac Arrest/epidemiology , Out-of-Hospital Cardiac Arrest/mortality , Retrospective Studies , Statistics, Nonparametric , Time Factors