Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 9.268
Filter
1.
Echocardiography ; 41(5): e15828, 2024 May.
Article in English | MEDLINE | ID: mdl-38762785

ABSTRACT

OBJECTIVES: To evaluate the clinical utility of two dimensional (2D) ultrasound combined with spatiotemporal image correlation (STIC) in diagnosing interrupted aortic arch (IAA) in fetal life. METHODS: A total of 53 cases of fetal IAA were diagnosed using 2D ultrasound combined with STIC, and 53 normal fetuses of the same gestational week were selected. These cases were retrospectively analyzed to assess the utility of employing 2D ultrasound combined with STIC in the diagnosis of IAA. RESULTS: 2D ultrasound combined with STIC detected 22 cases of type A IAA, 24 cases of type B IAA, and seven cases of type C IAA. Furthermore, combining 2D ultrasound with STIC enabled dynamic visualization of the IAA, aiding in prenatal diagnosis. The diagnostic coincidence rate of IAA was found to be higher in the HD-flow combined with STIC than that in the 2D combined with HD-flow. CONCLUSION: HD-flow combined with STIC can assist in diagnosing fetal IAA, and this technique has important clinical value.


Subject(s)
Aorta, Thoracic , Ultrasonography, Prenatal , Humans , Female , Ultrasonography, Prenatal/methods , Pregnancy , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/abnormalities , Aorta, Thoracic/embryology , Retrospective Studies , Adult , Reproducibility of Results , Fetal Heart/diagnostic imaging
3.
BMC Med Inform Decis Mak ; 24(1): 128, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38773456

ABSTRACT

BACKGROUND: Accurate segmentation of critical anatomical structures in fetal four-chamber view images is essential for the early detection of congenital heart defects. Current prenatal screening methods rely on manual measurements, which are time-consuming and prone to inter-observer variability. This study develops an AI-based model using the state-of-the-art nnU-NetV2 architecture for automatic segmentation and measurement of key anatomical structures in fetal four-chamber view images. METHODS: A dataset, consisting of 1,083 high-quality fetal four-chamber view images, was annotated with 15 critical anatomical labels and divided into training/validation (867 images) and test (216 images) sets. An AI-based model using the nnU-NetV2 architecture was trained on the annotated images and evaluated using the mean Dice coefficient (mDice) and mean intersection over union (mIoU) metrics. The model's performance in automatically computing the cardiac axis (CAx) and cardiothoracic ratio (CTR) was compared with measurements from sonographers with varying levels of experience. RESULTS: The AI-based model achieved a mDice coefficient of 87.11% and an mIoU of 77.68% for the segmentation of critical anatomical structures. The model's automated CAx and CTR measurements showed strong agreement with those of experienced sonographers, with respective intraclass correlation coefficients (ICCs) of 0.83 and 0.81. Bland-Altman analysis further confirmed the high agreement between the model and experienced sonographers. CONCLUSION: We developed an AI-based model using the nnU-NetV2 architecture for accurate segmentation and automated measurement of critical anatomical structures in fetal four-chamber view images. Our model demonstrated high segmentation accuracy and strong agreement with experienced sonographers in computing clinically relevant parameters. This approach has the potential to improve the efficiency and reliability of prenatal cardiac screening, ultimately contributing to the early detection of congenital heart defects.


Subject(s)
Heart Defects, Congenital , Ultrasonography, Prenatal , Humans , Heart Defects, Congenital/diagnostic imaging , Ultrasonography, Prenatal/methods , Female , Pregnancy , Fetal Heart/diagnostic imaging , Fetal Heart/anatomy & histology
4.
Biomed Phys Eng Express ; 10(4)2024 May 31.
Article in English | MEDLINE | ID: mdl-38781934

ABSTRACT

Congenital heart defects (CHD) are one of the serious problems that arise during pregnancy. Early CHD detection reduces death rates and morbidity but is hampered by the relatively low detection rates (i.e., 60%) of current screening technology. The detection rate could be increased by supplementing ultrasound imaging with fetal ultrasound image evaluation (FUSI) using deep learning techniques. As a result, the non-invasive foetal ultrasound image has clear potential in the diagnosis of CHD and should be considered in addition to foetal echocardiography. This review paper highlights cutting-edge technologies for detecting CHD using ultrasound images, which involve pre-processing, localization, segmentation, and classification. Existing technique of preprocessing includes spatial domain filter, non-linear mean filter, transform domain filter, and denoising methods based on Convolutional Neural Network (CNN); segmentation includes thresholding-based techniques, region growing-based techniques, edge detection techniques, Artificial Neural Network (ANN) based segmentation methods, non-deep learning approaches and deep learning approaches. The paper also suggests future research directions for improving current methodologies.


Subject(s)
Deep Learning , Heart Defects, Congenital , Neural Networks, Computer , Ultrasonography, Prenatal , Humans , Heart Defects, Congenital/diagnostic imaging , Ultrasonography, Prenatal/methods , Pregnancy , Female , Image Processing, Computer-Assisted/methods , Echocardiography/methods , Algorithms , Fetal Heart/diagnostic imaging , Fetus/diagnostic imaging
5.
BMC Pregnancy Childbirth ; 24(1): 264, 2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38605306

ABSTRACT

BACKGROUND: Maternal diabetes adversely affects fetal cardiovascular system development. Previous studies have reported that the fetuses of mothers with diabetes exhibit both structural and functional changes; nevertheless, prior studies have not examined the association between glucose control and fetal cardiac morphology and performance. Thus, the objective was to determine the association between fetal cardiac morphology and function and maternal glucose control in type 1 diabetes and to compare the differences in measured cardiac parameters between the fetuses of mothers with diabetes and healthy controls. METHODS: In this prospective, longitudinal case-control study - including 62 pregnant women with type 1 diabetes mellitus and 30 healthy pregnant women - fetal cardiac assessment using B-mode, M-mode, and spectral pulsed-wave Doppler was performed in the second and third trimesters. In women with T1DM, glycated hemoglobin and data obtained from glucose sensors - including the percentage of time in, below, and above the range (TIR, TBR, and TAR, respectively), and coefficient of variation (CV) - were analyzed across three time periods: the last menstrual period to 13 (V1), 14-22 (V2), and 23-32 weeks (V3) of gestation. Fetal cardiac indices were compared between groups, and the correlation between glucose control and fetal cardiac indices was assessed. RESULTS: At 28-32 weeks, the fetuses of women with T1DM exhibited increased left ventricular end-diastolic length, relative interventricular septum thickness, right ventricular cardiac output, and pulmonary valve peak systolic velocity compared with healthy controls. At 18-22 weeks, pulmonary and aortic valve diameters, left and right ventricular stroke volumes, and left cardiac output inversely correlated with the CV and glycated hemoglobin levels at V1 and V2. Furthermore, at 28-32 weeks, pulmonary and aortic valve diameters, left ventricular stroke volume, cardiac output, and right/left atrioventricular valve ratio inversely correlated with the TBR at V1, V2, and V3. Moreover, diastolic functional parameters correlated with the TAR and glycated hemoglobin levels, particularly after the first trimester. CONCLUSION: In women with T1DM, maternal hyperglycemia during pregnancy correlates with fetal diastolic function, whereas glucose variability and hypoglycemia inversely correlate with fetal left ventricular systolic function in the second and third trimesters.


Subject(s)
Diabetes Mellitus, Type 1 , Diabetes, Gestational , Nijmegen Breakage Syndrome , Pregnancy , Humans , Female , Diabetes Mellitus, Type 1/complications , Echocardiography, Doppler , Blood Glucose , Glycated Hemoglobin , Prospective Studies , Case-Control Studies , Longitudinal Studies , Fetal Heart/diagnostic imaging , Hemodynamics , Ultrasonography, Prenatal
6.
Biomed Eng Online ; 23(1): 39, 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38566181

ABSTRACT

BACKGROUND: Congenital heart disease (CHD) is one of the most common birth defects in the world. It is the leading cause of infant mortality, necessitating an early diagnosis for timely intervention. Prenatal screening using ultrasound is the primary method for CHD detection. However, its effectiveness is heavily reliant on the expertise of physicians, leading to subjective interpretations and potential underdiagnosis. Therefore, a method for automatic analysis of fetal cardiac ultrasound images is highly desired to assist an objective and effective CHD diagnosis. METHOD: In this study, we propose a deep learning-based framework for the identification and segmentation of the three vessels-the pulmonary artery, aorta, and superior vena cava-in the ultrasound three vessel view (3VV) of the fetal heart. In the first stage of the framework, the object detection model Yolov5 is employed to identify the three vessels and localize the Region of Interest (ROI) within the original full-sized ultrasound images. Subsequently, a modified Deeplabv3 equipped with our novel AMFF (Attentional Multi-scale Feature Fusion) module is applied in the second stage to segment the three vessels within the cropped ROI images. RESULTS: We evaluated our method with a dataset consisting of 511 fetal heart 3VV images. Compared to existing models, our framework exhibits superior performance in the segmentation of all the three vessels, demonstrating the Dice coefficients of 85.55%, 89.12%, and 77.54% for PA, Ao and SVC respectively. CONCLUSIONS: Our experimental results show that our proposed framework can automatically and accurately detect and segment the three vessels in fetal heart 3VV images. This method has the potential to assist sonographers in enhancing the precision of vessel assessment during fetal heart examinations.


Subject(s)
Deep Learning , Pregnancy , Female , Humans , Vena Cava, Superior , Ultrasonography , Ultrasonography, Prenatal/methods , Fetal Heart/diagnostic imaging , Image Processing, Computer-Assisted/methods
7.
Radiol Cardiothorac Imaging ; 6(2): e230182, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38602469

ABSTRACT

Fetal cardiac MRI using Doppler US gating is an emerging technique to support prenatal diagnosis of congenital heart disease and other cardiovascular abnormalities. Analogous to postnatal electrocardiographically gated cardiac MRI, this technique enables directly gated MRI of the fetal heart throughout the cardiac cycle, allowing for immediate data reconstruction and review of image quality. This review outlines the technical principles and challenges of cardiac MRI with Doppler US gating, such as loss of gating signal due to fetal movement. A practical workflow of patient preparation for the use of Doppler US-gated fetal cardiac MRI in clinical routine is provided. Currently applied MRI sequences (ie, cine or four-dimensional flow imaging), with special consideration of technical adaptations to the fetal heart, are summarized. The authors provide a literature review on the clinical benefits of Doppler US-gated fetal cardiac MRI for gaining additional diagnostic information on cardiovascular malformations and fetal hemodynamics. Finally, future perspectives of Doppler US-gated fetal cardiac MRI and further technical developments to reduce acquisition times and eliminate sources of artifacts are discussed. Keywords: MR Fetal, Ultrasound Doppler, Cardiac, Heart, Congenital, Obstetrics, Fetus Supplemental material is available for this article. © RSNA, 2024.


Subject(s)
Magnetic Resonance Imaging , Prenatal Care , Female , Pregnancy , Humans , Radiography , Fetal Heart/diagnostic imaging , Technology
8.
Early Hum Dev ; 192: 106006, 2024 May.
Article in English | MEDLINE | ID: mdl-38598864

ABSTRACT

BACKGROUND: Behcet's disease usually progresses with remission during pregnancy, but early subtle changes might be detected in the heart of these fetuses due to inflammation. AIMS: We aimed to evaluate the cardiac functions in fetuses of pregnant women with Behcet's disease (BD). STUDY DESIGN: Prospective case-control study. SUBJECTS: This prospective study enrolled pregnant women diagnosed with Behcet's disease before pregnancy. Twenty-four pregnancies with Behcet's disease and 48 healthy pregnancies were included at 32-34 gestational weeks. OUTCOME MEASURES: Pulsed-wave Doppler and tissue Doppler imaging (TDI) were used to assess cardiac functions. RESULTS: Right ventricle (RV) E (early) wave and left ventricle (LV) E were significantly increased in pregnancies with BD (p = .008, p = .041, respectively). Decreased right ventricle E' (peak systolic velocity) was detected with TDI in the case group (6.2 ± 0.5, p < .001). E/E' ratios for RV and LV were significantly increased in the case group (p < .001, p = .001, respectively). The correlation between the duration of the disease and fetal cardiac functions was also evaluated. For RV, E (r = 0.735, p < .001), E' (r = -0.735, p < .001), E/E' (r = 0.894, p < .001), were strongly correlated with the disease duration. The study also showed the correlation between disease duration and LV E' (r = -0.735, p = .005), LV E (r = 0.750, p < .001), and LV E/E' (r = 0.820, p < .001). CONCLUSION: This is the first study to evaluate the fetal cardiac functions in fetuses of pregnancies with BD. Although BD usually progresses with remission during pregnancy, early subclinical diastolic changes might occur in the heart of these fetuses due to inflammation.


Subject(s)
Behcet Syndrome , Fetal Heart , Ultrasonography, Prenatal , Humans , Female , Pregnancy , Behcet Syndrome/physiopathology , Behcet Syndrome/diagnostic imaging , Case-Control Studies , Adult , Fetal Heart/diagnostic imaging , Fetal Heart/physiopathology , Prospective Studies
9.
Int J Cardiovasc Imaging ; 40(5): 1157-1158, 2024 May.
Article in English | MEDLINE | ID: mdl-38652393

ABSTRACT

Transposition of the great arteries (TGA) is a cyanotic congenital heart disease characterized by ventriculoarterial discordance and atrioventricular concordance with the great arteries in a parallel relationship. Prenatal diagnosis of TGA has implications for postnatal outcomes, allowing for planned delivery and perinatal management. Three-dimensional virtual or physical models of fetal TGA allow better understanding of fetal cardiac anomalies by parents and interactive discussion among the multidisciplinary team (obstetricians, pediatricians, maternal-fetal specialists, pediatric cardiologists, and cardiovascular surgeons), as well as continuing medical education.


Subject(s)
Fetal Heart , Predictive Value of Tests , Transposition of Great Vessels , Ultrasonography, Prenatal , Transposition of Great Vessels/diagnostic imaging , Transposition of Great Vessels/surgery , Transposition of Great Vessels/physiopathology , Humans , Pregnancy , Fetal Heart/diagnostic imaging , Fetal Heart/physiopathology , Female , Imaging, Three-Dimensional , Models, Cardiovascular , Gestational Age , Patient-Specific Modeling , Prognosis , Image Interpretation, Computer-Assisted
10.
J Perinat Med ; 52(5): 538-545, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38639637

ABSTRACT

OBJECTIVES: Cardiopulmonary and infectious complications are more common in preterm newborns after preterm premature rupture of membranes (pPROM). Fetal echocardiography may be helpful in predicting neonatal condition. Our aim was to assess the cardiovascular changes in fetuses from pregnancies complicated by pPROM and possible utility in predicting the intrauterine or neonatal infection, and neonatal heart failure (HF). METHODS: It was a prospective study enrolling 46 women with singleton pregnancies complicated by pPROM between 18+0 and 33+6 weeks of gestation and followed until delivery. 46 women with uncomplicated pregnancies served as a control group. Fetal echocardiographic examinations with the assessment of cardiac structure and function (including pulmonary circulation) were performed in all patients. RESULTS: Mean gestational age of pPROM patients was 26 weeks. Parameters suggesting impaired cardiac function in fetuses from pPROM were: higher right ventricle Tei index (0.48 vs. 0.42 p<0.001), lower blood flow velocity in Ao z-score (0.14 vs. 0.84 p=0.005), lower cardiovascular profile score (CVPS), higher rate of tricuspid regurgitation (18.2 % vs. 4.4 % p=0.04) and pericardial effusion (32.6 vs. 0 %). Intrauterine infection was diagnosed in 18 patients (39 %). 4 (8.7 %) newborns met the criteria of early onset sepsis (EOS). HF was diagnosed in 9 newborns. In fetal echocardiographic examination HF group had shorter mitral valve inflow time and higher left ventricle Tei index (0.58 vs. 0.49 p=0.007). CONCLUSIONS: Worse cardiac function was observed in fetuses from pPROM compared to fetuses from uncomplicated pregnancies.


Subject(s)
Echocardiography , Fetal Membranes, Premature Rupture , Ultrasonography, Prenatal , Humans , Female , Pregnancy , Fetal Membranes, Premature Rupture/diagnosis , Fetal Membranes, Premature Rupture/diagnostic imaging , Adult , Echocardiography/methods , Prospective Studies , Ultrasonography, Prenatal/methods , Infant, Newborn , Fetal Heart/diagnostic imaging , Fetal Heart/physiopathology , Case-Control Studies , Gestational Age
11.
J Matern Fetal Neonatal Med ; 37(1): 2323623, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38443062

ABSTRACT

OBJECTIVE: To describe international surveillance and treatment strategies for managing anti-SSA/Ro autoantibody positive pregnancies. STUDY DESIGN: An electronic REDCap questionnaire was distributed to Fetal Heart Society and North American Fetal Therapy Network members which queried institution-based risk stratification, surveillance methods/frequency, conduction abnormality treatments, and postnatal anti-SSA/Ro pregnancy assessment. RESULTS: 101 responses from 59 centers (59% US, 17% international) were collected. Most (79%) do not risk stratify pregnancies by anti-SSA/Ro titer; those that do use varied cutoff values. Many pregnant rheumatology patients are monitored for cardiac abnormalities regardless of maternal anti-SSA/Ro status. Surveillance strategies were based on maternal factors (anti-SSA/Ro status 85%, titer 25%, prior affected child 79%) and monitoring durations varied. Most respondents treat 2° and 3° fetal atrioventricular block, commonly with dexamethasone and/or IVIG. CONCLUSIONS: Wide variation exists in current fetal cardiac surveillance and treatment for anti-SSA/Ro autoantibody positive pregnancies, highlighting the need for evidence-based protocols to optimize care.


Subject(s)
Atrioventricular Block , Child , Female , Pregnancy , Humans , Autoantibodies , Fetal Heart , Health Facilities , Prenatal Care , Vitamins
12.
J Am Heart Assoc ; 13(6): e031184, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38497437

ABSTRACT

BACKGROUND: Distances between delivery and cardiac services can make the care of fetuses with cardiac disease at risk of acute cardiorespiratory instability at birth a challenge. In 2013 we implemented a fetal echocardiography-based algorithm targeting fetuses considered high risk for acute cardiorespiratory instability at ≤2 hours of birth for delivery in our pediatric cardiac operating room of our children's hospital, and, herein, examine our experience. METHODS AND RESULTS: We reviewed maternal and postnatal medical records of all fetuses with cardiac disease encountered January 2013 to March 2022 considered high risk for acute cardiorespiratory instability. Secondary analysis was performed including all fetuses with diagnoses of d-transposition of the great arteries/intact ventricular septum (d-TGA/IVS) and hypoplastic left heart syndrome (HLHS) encountered over the study period. Forty fetuses were considered high risk for acute cardiorespiratory instability: 15 with d-TGA/IVS and 7 with HLHS with restrictive atrial septum, 4 with absent pulmonary valve syndrome, 3 with obstructed anomalous pulmonary veins, 2 with severe Ebstein anomaly, 2 with thoracic/intracardiac tumors, and 7 others. Pediatric cardiac operating room delivery occurred for 33 but not for 7 (5 with d-TGA/IVS, 2 with HLHS with restrictive atrial septum). For high-risk cases, fetal echocardiography had a positive predictive value of 50% for intervention/extracorporeal membrane oxygenation/death at ≤2 hours and 70% at ≤24 hours. Of "low-risk" cases, 6/46 with d-TGA/IVS and 0/45 with HLHS required intervention at ≤2 hours. Fetal echocardiography for predicting intervention/extracorporeal membrane oxygenation/death at ≤2 hours had a sensitivity of 67%, specificity 93%, and positive and negative predictive values of 80% and 87%, respectively, for d-TGA/IVS, and 100%, 95%, 71%, and 100% for HLHS, respectively. CONCLUSIONS: Fetal echocardiography can predict the need for urgent intervention in a majority with d-TGA/IVS and HLHS and in half of the entire spectrum of high-risk cardiac disease.


Subject(s)
Heart Defects, Congenital , Hypoplastic Left Heart Syndrome , Transposition of Great Vessels , Pregnancy , Infant, Newborn , Female , Humans , Child , Operating Rooms , Fetal Heart/diagnostic imaging , Fetal Heart/surgery , Ultrasonography, Prenatal/methods , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Hypoplastic Left Heart Syndrome/diagnostic imaging , Hypoplastic Left Heart Syndrome/surgery , Retrospective Studies
14.
BMC Pregnancy Childbirth ; 24(1): 141, 2024 Feb 16.
Article in English | MEDLINE | ID: mdl-38365664

ABSTRACT

OBJECTIVE: Whether or not the effects of anemia in the early phase, while the fetuses attempts to increase cardiac output to meet oxygen requirement in peripheral organs, is detrimental to the fetal developing vital organs is little-known. The objective of this is to compare prenatal cardiovascular changes and post-abortal cellular damages in the myocardium as a pumping organ and the brain as a perfused organ between anemic fetuses (using fetal Hb Bart's disease as a study model) in pre-hydropic phase and non-anemic fetuses. METHODS: Fetuses affected by Hb Bart's disease and non-anemic fetuses at 16-22 weeks were recruited to undergo comprehensive fetal echocardiography. Cord blood analysis was used to confirm the definite diagnosis of fetal Hb Bart's disease and normal fetuses. Fetal cardiac and brain tissues were collected shortly after pregnancy termination for the determination of oxidative stress and mitochondrial function, including mitochondrial ROS production and mitochondrial membrane changes. RESULTS: A total of 18 fetuses affected by Hb Bart's disease and 13 non-anemic fetuses were recruited. The clinical characteristics of both groups were comparable. The affected fetuses showed a significant increase in cardiac dimensions, cardiac function, cardiac output and brain circulation without deteriorating cardiac contractility and preload. However, in the affected fetuses, mitochondrial dysfunction was clearly demonstrated in brain tissues and in the myocardium, as indicated by a significant increase in the membrane potential change (p-value < 0.001), and a significant increase in ROS production in brain tissues, with a trend to increase in myocardium. The findings indicated cellular damage in spite of good clinical compensation. CONCLUSION: The new insight is that, in response to fetal anemia, fetal heart increases in size (dilatation) and function to increase cardiac output and blood flow velocity to provide adequate tissue perfusion, especially brain circulation. However, the myocardium and brain showed a significant increase in mitochondrial dysfunction, suggesting cellular damage secondary to anemic hypoxia. The compensatory increase in circulation could not completely prevent subtle brain and heart damage.


Subject(s)
Anemia , Fetal Diseases , Hemoglobins, Abnormal , Mitochondrial Diseases , alpha-Thalassemia , Female , Pregnancy , Humans , Pregnancy Trimester, Second , Reactive Oxygen Species , Hemoglobins, Abnormal/analysis , Fetal Diseases/diagnosis , Fetal Heart/diagnostic imaging , Myocardium/chemistry , Edema , Cardiac Output
15.
Pediatr Cardiol ; 45(4): 740-748, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38393337

ABSTRACT

Morphology and function in a fetal heart with severe tricuspid regurgitation remains challenging. The aim of this study was to assess cardiac morphology and function in fetuses with severe tricuspid regurgitation by fetal heart quantification (HQ) and to assess the practical value of fetal HQ. Clinical information was analyzed for 63 pregnant women who underwent fetal cardiac ultrasonography. The women were divided into those who had a fetus with severe tricuspid regurgitation (n = 20) and those with a normal fetus (n = 40). The global sphericity index (GSI), fractional area change (FAC), and global longitudinal strain (GLS) of both ventricles and the sphericity index (SI) and fractional shortening (FS) of 24 segments were quantified by fetal HQ using speckle tracking imaging. Fetuses with severe tricuspid regurgitation had a significantly lower GSI (1.14 ± 0.10 vs. 1.26 ± 0.08, p < 0.001) and a higher GSI Z-score (-0.98 ± 1.01 vs. 0.25 ± 0.87, p < 0.001) as well as a significantly lower right ventricular FAC (36.50 ± 7.34% vs. 45.19 ± 3.39%, p < 0.001), FAC Z-score (-1.02 ± 1.41 vs. 0.49 ± 0.74, p < 0.001), and GLS (-21.01 ± 5.66% vs. 45.19 ± 3.49%, p < 0.001). The SI and SI Z-score were significantly lower in segments 1-18 of the right ventricle in fetuses with severe tricuspid regurgitation (p < 0.05); furthermore, FS of segments 1-12 and 19-24 and the FS Z-score of segments 18-24 were significantly lower in fetuses with severe tricuspid regurgitation (p < 0.05). Fetal HQ is useful for evaluation of cardiac morphology and function in fetuses with severe tricuspid regurgitation and can provide important reference information for both clinical diagnosis and treatment.


Subject(s)
Tricuspid Valve Insufficiency , Humans , Female , Pregnancy , Tricuspid Valve Insufficiency/diagnostic imaging , Fetal Heart/diagnostic imaging , Heart Ventricles , Ultrasonography, Prenatal/methods
17.
IEEE J Biomed Health Inform ; 28(5): 2943-2954, 2024 May.
Article in English | MEDLINE | ID: mdl-38412077

ABSTRACT

In the fetal cardiac ultrasound examination, standard cardiac cycle (SCC) recognition is the essential foundation for diagnosing congenital heart disease. Previous studies have mostly focused on the detection of adult CCs, which may not be applicable to the fetus. In clinical practice, localization of SCCs needs to recognize end-systole (ES) and end-diastole (ED) frames accurately, ensuring that every frame in the cycle is a standard view. Most existing methods are not based on the detection of key anatomical structures, which may not recognize irrelevant views and background frames, results containing non-standard frames, or even it does not work in clinical practice. We propose an end-to-end hybrid neural network based on an object detector to detect SCCs from fetal ultrasound videos efficiently, which consists of 3 modules, namely Anatomical Structure Detection (ASD), Cardiac Cycle Localization (CCL), and Standard Plane Recognition (SPR). Specifically, ASD uses an object detector to identify 9 key anatomical structures, 3 cardiac motion phases, and the corresponding confidence scores from fetal ultrasound videos. On this basis, we propose a joint probability method in the CCL to learn the cardiac motion cycle based on the 3 cardiac motion phases. In SPR, to reduce the impact of structure detection errors on the accuracy of the standard plane recognition, we use XGBoost algorithm to learn the relation knowledge of the detected anatomical structures. We evaluate our method on the test fetal ultrasound video datasets and clinical examination cases and achieve remarkable results. This study may pave the way for clinical practices.


Subject(s)
Fetal Heart , Image Interpretation, Computer-Assisted , Neural Networks, Computer , Ultrasonography, Prenatal , Humans , Ultrasonography, Prenatal/methods , Female , Pregnancy , Image Interpretation, Computer-Assisted/methods , Fetal Heart/diagnostic imaging , Fetal Heart/physiology , Algorithms , Heart Defects, Congenital/diagnostic imaging , Video Recording/methods
18.
J Physiol ; 602(4): 663-681, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38324229

ABSTRACT

Fetal critical aortic stenosis with evolving hypoplastic left heart syndrome (CAS-eHLHS) causes biomechanical and functional aberrations, leading to a high risk of progression to hypoplastic left heart syndrome (HLHS) at birth. Fetal aortic valvuloplasty (FAV) can resolve outflow obstruction and may reduce progression risk. However, it is currently difficult to accurately predict which patients will respond to the intervention and become functionally biventricular (BV) at birth, as opposed to becoming functionally univentricular (UV). This prediction is important for patient selection, parental counselling, and surgical planning. Therefore, we investigated whether biomechanics parameters from pre-FAV image-based computations could robustly distinguish between CAS-eHLHS cases with BV or UV outcomes in a retrospective cohort. To do so we performed image-based finite element biomechanics modelling of nine CAS-eHLHS cases undergoing intervention and six healthy fetal control hearts, and found that a biomechanical parameter, peak systolic myofibre stress, showed a uniquely large difference between BV and UV cases, which had a larger magnitude effect than echocardiography parameters. A simplified equation was derived for quick and easy estimation of myofibre stress from echo measurements via principal component analysis. When tested on a retrospective cohort of 37 CAS-eHLHS cases, the parameter outperformed other parameters in predicting UV versus BV outcomes, and thus has a high potential of improving outcome predictions, if incorporated into patient selection procedures. Physiologically, high myocardial stresses likely indicate a healthier myocardium that can withstand high stresses and resist pathological remodelling, which can explain why it is a good predictor of BV outcomes. KEY POINTS: Predicting the morphological birth outcomes (univentricular versus biventricular) of fetal aortic valvuloplasty for fetal aortic stenosis with evolving HLHS is important for accurate patient selection, parental counselling and management decisions. Computational simulations show that a biomechanics parameter, pre-intervention peak systolic myofibre stress, is uniquely robust in distinguishing between such outcomes, outperforming all echo parameters. An empirical equation was developed to quickly compute peak systolic myofibre stress from routine echo measurements and was the best predictor of outcomes among a wide range of parameters tested.


Subject(s)
Aortic Valve Stenosis , Hypoplastic Left Heart Syndrome , Infant, Newborn , Humans , Hypoplastic Left Heart Syndrome/diagnostic imaging , Hypoplastic Left Heart Syndrome/therapy , Hypoplastic Left Heart Syndrome/etiology , Retrospective Studies , Aortic Valve Stenosis/diagnostic imaging , Fetal Heart , Myocardium
19.
J Perinat Med ; 52(3): 322-326, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38298153

ABSTRACT

OBJECTIVES: To evaluate the changes of cardiac morphology and function in fetuses conceived through assisted reproductive technologies (ART) by speckle tracking echocardiography. METHODS: A retrospective study was conducted in 101 spontaneously conceived (SC) fetuses and 99 ART-conceived ones. Fetal echocardiography was performed, fetal cardiac morphology and function were analyzed using two-dimensional speckle tracking software, including global sphericity index (GSI), global longitudinal strain (GLS), fractional area change (FAC) of the left and right ventricles, as well as segmental sphericity index (SI), end-diastolic diameter (ED), and fractional shortening (FS) in 24 segments. RESULTS: Compared to the SC fetuses, the ART-conceived fetuses exhibited decreased GSI (median [interquartile range], 1.22 [1.16-1.27] vs. 1.18 [1.11-1.24], p=0.007), decreased right ventricular GLS (24.9 [21.5-27.6] vs. 23.2 [20.4-26.8], p=0.026), and decreased right ventricular FAC (mean ± standard deviation, 39.7 ± 6.4 vs. 37.2 ± 7.1, p=0.003). Analysis of the 24 segments showed that ART-conceived fetuses had reduced SI in the apical segments of right ventricle and increased ED in several segments of the right ventricle. CONCLUSIONS: Fetuses conceived through ART had a more spherical shape of the global heart and predominantly right-sided cardiac remodeling and systolic function impairment.


Subject(s)
Echocardiography , Fetal Heart , Humans , Retrospective Studies , Fetal Heart/diagnostic imaging , Echocardiography/methods , Heart Ventricles/diagnostic imaging , Reproductive Techniques, Assisted
20.
Heart Rhythm ; 21(5): 600-609, 2024 May.
Article in English | MEDLINE | ID: mdl-38266752

ABSTRACT

BACKGROUND: The motion relationship and time intervals of the pulsed-wave Doppler (PWD) spectrum are essential for diagnosing fetal arrhythmia. However, few technologies currently are available to automatically calculate fetal cardiac time intervals (CTIs). OBJECTIVE: The purpose of this study was to develop a fetal heart rhythm intelligent quantification system (HR-IQS) for the automatic extraction of CTIs and establish the normal reference range for fetal CTIs. METHODS: A total of 6498 PWD spectrums of 2630 fetuses over the junction between the left ventricular inflow and outflow tracts were recorded across 14 centers. E, A, and V waves were manually labeled by 3 experienced fetal cardiologists, with 17 CTIs extracted. Five-fold cross-validation was performed for training and testing of the deep learning model. Agreement between the manual and HR-IQS-based values was evaluated using the intraclass correlation coefficient and Spearman's rank correlation coefficient. The Jarque-Bera test was applied to evaluate the normality of CTIs' distributions, and the normal reference range of 17 CTIs was established with quantile regression. Arrhythmia subset was compared with the non-arrhythmia subset using the Mann-Whitney U test. RESULTS: Significant positive correlation (P <.001) and moderate-to-excellent consistency (P <.001) between the manual and HR-IQS automated measurements of CTIs was found. The distribution of CTIs was non-normal (P <.001). The normal range (2.5th to 97.5th percentiles) was successfully established for the 17 CTIs. CONCLUSIONS: Using our HR-IQS is feasible for the automated calculation of CTIs in practice and thus could provide a promising tool for the assessment of fetal rhythm and function.


Subject(s)
Arrhythmias, Cardiac , Fetal Heart , Heart Rate, Fetal , Humans , Female , Prospective Studies , Pregnancy , Heart Rate, Fetal/physiology , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Fetal Heart/diagnostic imaging , Fetal Heart/physiology , Gestational Age , Ultrasonography, Prenatal/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...