Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 19.868
Filter
1.
Medicine (Baltimore) ; 103(18): e37979, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38701293

ABSTRACT

Older children over 8 years old are at higher risk of elbow joint stiffness after treatment of supracondylar humeral fractures. The objective of this study was to improve the Slongo's external fixation system for treating supracondylar humeral fractures in older children. This would be achieved by increasing fixation strength and providing a theoretical basis through finite element analysis and mechanical testing. A 13-year-old female patient with a history of previous fracture was selected for CT data processing to create a three-dimensional model of the distal humerus fracture. Two internal fixation models were established, using the Slongo's external fixation method with Kirschner wire (Group A) and modifying the Slongo's external fixation (Kirschner wire tail fixation) (Group B). The fracture models were then subjected to mechanical loading analysis using Finite Element Analysis Abaqus 6.14 software to simulate separation, internal rotation, and torsion loads. A PVC humeral bone model was used to create a supracondylar fracture model, and the A and B internal fixation methods were applied separately. The anterior-posterior and torsional stresses were measured using the Bose Electroforce3510 testing system, followed by a comparative analysis. The finite element simulation results showed that under the same tensile, torsion, and inversion forces, the osteotomy model fixed with Kirschner wire at the distal end in Group B exhibited smaller tensile stress and deformation compared to the unfixed osteotomy model in Group A. This indicated that the fixation strength of Group B was superior to that of Group A. According to the test results of the Bose Electroforce3510 testing system, a simple linear regression analysis was conducted using SPSS software. The K values of rotation angle-torque tests and front and rear displacement-stress tests were calculated for Groups A and B, with Group B showing higher values than Group A. The results of this study supported the significantly enhanced biomechanical reliability and stability of fracture fixation in Group B, which utilized the modified Slongo's external fixation (Kirschner wire tail fixation). This optimized method provides a new choice for the clinical treatment of supracondylar humeral fractures in older children, backed by both clinical evidence and theoretical basis.


Subject(s)
External Fixators , Finite Element Analysis , Fracture Fixation , Humeral Fractures , Humans , Humeral Fractures/surgery , Female , Adolescent , Fracture Fixation/methods , Bone Wires , Biomechanical Phenomena , Tomography, X-Ray Computed
2.
PLoS One ; 19(5): e0301329, 2024.
Article in English | MEDLINE | ID: mdl-38709745

ABSTRACT

It is imperative to understand how foundations behave on earthen slopes to accurately predict their allowable carrying capacity in geotechnical engineering. A comprehensive finite element (FE) simulation with PLAXIS 2D was conducted to assess the effects of various parameters on the bearing capacity (BC) of single- and double-strip foundations placed near the earth's slope crest. The specified parameters include foundation width (B) and depth (Df/B); setback distance between the slope edge and foundation (b/B); soil internal friction (ϕ) and cohesion (c); slope inclination (ß); and spacing between foundations (S/B). In addition, the numerically simulated database was used to develop simple mathematical expressions for predicting the capacities in both cases using evolutionary polynomial regression (EPR). The results revealed that the bearing capacity of single- and double-strip foundations increased with an increase in all studied parameters except slope inclination. For single-strip foundations, the outcomes demonstrated that slope inclination has no impact on BC when it is located 6B from the slope edge. However, under interference conditions, the critical center-to-center spacing between foundations is 3-4B, beyond which they behave as individual foundations. Additionally, EPR provides a robust method of predicting the BC of single- and double-strip foundations within slope crests based on the strong correlation of various statistical criteria between simulated and predicted results from training, validation, and testing. Finally, according to sensitivity analysis, in both single and double-strip foundations resting on an earthen slope crest, b/B, B, and ϕ are the most important input parameters that impact the output results.


Subject(s)
Earth, Planet , Models, Theoretical , Soil/chemistry , Finite Element Analysis , Computer Simulation
3.
J Morphol ; 285(5): e21707, 2024 May.
Article in English | MEDLINE | ID: mdl-38721681

ABSTRACT

Using finite element analysis on the astragali of five macropodine kangaroos (extant and extinct hoppers) and three sthenurine kangaroos (extinct proposed bipedal striders) we investigate how the stresses experienced by the ankle in similarly sized kangaroos of different hypothesized/known locomotor strategy compare under different simulation scenarios, intended to represent the moment of midstance at different gaits. These tests showed a clear difference between the performance of sthenurines and macropodines with the former group experiencing lower stress in simulated bipedal strides in all species compared with hopping simulations, supporting the hypothesis that sthenurines may have utilized this gait. The Pleistocene macropodine Protemnodon also performed differently from all other species studied, showing high stresses in all simulations except for bounding. This may support the hypothesis of Protemnodon being a quadrupedal bounder.


Subject(s)
Finite Element Analysis , Macropodidae , Animals , Macropodidae/physiology , Macropodidae/anatomy & histology , Ankle/physiology , Biomechanical Phenomena , Gait/physiology , Locomotion/physiology , Stress, Mechanical
4.
Transl Vis Sci Technol ; 13(5): 2, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38696181

ABSTRACT

Purpose: Currently, no solution exists to restore natural eyelid kinematics for patients with complete eyelid paralysis due to loss of function of both the levator palpebrae superioris and orbicularis oculi. These rare cases are prone to complications of chronic exposure keratopathy which may lead to corneal blindness. We hypothesized that magnetic force could be used to fully automate eyelid movement in these cases through the use of eyelid-attached magnets and a spectacle-mounted magnet driven by a programmable motor (motorized magnetic levator prosthesis [MMLP]). Methods: To test this hypothesis and establish proof of concept, we performed a finite element analysis (FEA) for a prototype MMLP to check the eyelid-opening force generated by the device and verified the results with experimental measurements in a volunteer with total bidirectional eyelid paralysis. The subject was then fitted with a prototype to check the performance of the device and its success. Results: With MMLP, eye opening was restored to near normal, and blinking was fully automated in close synchrony with the motor-driven polarity reversal, with full closure on the blink. The device was well tolerated, and the participant was pleased with the comfort and performance. Conclusions: FEA simulation results conformed to the experimentally observed trend, further supporting the proof of concept and design parameters. This is the first viable approach in human patients with proof of concept for complete reanimation of a bidirectionally paretic eyelid. Further study is warranted to refine the prototype and determine the feasibility and safety of prolonged use. Translational Relevance: This is first proof of concept for our device for total bidirectional eyelid paralysis.


Subject(s)
Blinking , Eyelids , Proof of Concept Study , Humans , Blinking/physiology , Eyelids/physiopathology , Eyelid Diseases/physiopathology , Eyelid Diseases/therapy , Oculomotor Muscles/physiopathology , Finite Element Analysis , Biomechanical Phenomena , Prostheses and Implants , Prosthesis Design , Magnets , Male
5.
Sci Rep ; 14(1): 10322, 2024 05 06.
Article in English | MEDLINE | ID: mdl-38710745

ABSTRACT

Blade cut-out is a common complication when using proximal femoral nail anti-rotation (PFNA) for the treatment of intertrochanteric fractures. Although cement augmentation has been introduced to overcome the cut-out effect, the micromechanics of this approach remain to be clarified. While previous studies have developed finite element (FE) models based on lab-prepared or cadaveric samples to study the cement-trabeculae interface, their demanding nature and inherent disadvantages limit their application. The aim of this study was to develop a novel 'one-step forming' method for creating a cement-trabeculae interface FE model to investigate its micromechanics in relation to PFNA with cement augmentation. A human femoral head was scanned using micro-computed tomography, and four volume of interest (VOI) trabeculae were segmented. The VOI trabeculae were enclosed within a box to represent the encapsulated region of bone cement using ANSYS software. Tetrahedral meshing was performed with Hypermesh software based on Boolean operation. Finally, four cement-trabeculae interface FE models comprising four interdigitated depths and five FE models comprising different volume fraction were established after element removal. The effects of friction contact, frictionless contact, and bond contact properties between the bone and cement were identified. The maximum micromotion and stress in the interdigitated and loading bones were quantified and compared between the pre- and post-augmentation situations. The differences in micromotion and stress with the three contact methods were minimal. Micromotion and stress decreased as the interdigitation depth increased. Stress in the proximal interdigitated bone showed a correlation with the bone volume fraction (R2 = 0.70); both micromotion (R2 = 0.61) and stress (R2 = 0.93) at the most proximal loading region exhibited a similar correlation tendency. When comparing the post- and pre-augmentation situations, micromotion reduction in the interdigitated bone was more effective than stress reduction, particularly near the cement border. The cementation resulted in a significant reduction in micromotion within the loading bone, while the decrease in stress was minimal. Noticeable gradients of displacement and stress reduction can be observed in models with lower bone volume fraction (BV/TV). In summary, cement augmentation is more effective at reducing micromotion rather than stress. Furthermore, the reinforcing impact of bone cement is particularly prominent in cases with a low BV/TV. The utilization of bone cement may contribute to the stabilization of trabecular bone and PFNA primarily by constraining micromotion and partially shielding stress.


Subject(s)
Bone Cements , Bone Nails , Finite Element Analysis , Hip Fractures , Humans , Hip Fractures/surgery , X-Ray Microtomography , Biomechanical Phenomena , Femur Head , Rotation
6.
Sci Rep ; 14(1): 12243, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38806607

ABSTRACT

Stress shielding and aseptic loosening are complications of short stem total hip arthroplasty, which may lead to hardware failure. Stems with increased porosity toward the distal end were discovered to be effective in reducing stress shielding, however, there is a lack of research on optimized porous distribution in stem's coating. This study aimed to optimize the distribution of the coefficient of friction of a metaphyseal femoral stem, aiming for reducing stress shielding in the proximal area. A finite element analysis model of an implanted, titanium alloy short-tapered wedge stem featuring a porous coating made of titanium was designed to simulate a static structural analysis of the femoral stem's behavior under axial loading in Analysis System Mechanical Software. For computational feasibility, 500 combinations of coefficients of friction were randomly sampled. Increased strains in proximal femur were found in 8.4% of the models, which had decreased coefficients of friction in middle medial areas of porous coating and increased in lateral proximal and lateral and medial distal areas. This study reported the importance of the interface between bone and middle medial and distal lateral areas of the porous coating in influencing the biomechanical behavior of the proximal femur, and potentially reducing stress shielding.


Subject(s)
Arthroplasty, Replacement, Hip , Femur , Finite Element Analysis , Friction , Hip Prosthesis , Titanium , Humans , Femur/physiology , Porosity , Arthroplasty, Replacement, Hip/methods , Titanium/chemistry , Stress, Mechanical , Prosthesis Design , Coated Materials, Biocompatible/chemistry , Biomechanical Phenomena , Alloys/chemistry
7.
Clin Exp Dent Res ; 10(3): e893, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38770579

ABSTRACT

OBJECTIVES: The present study reviews the current literature regarding the utilization of the extended finite element method (XFEM) in clinical and experimental endodontic studies and the suitability of XFEM in the assessment of cyclic fatigue in rotary endodontic nickel-titanium (NiTi) instruments. MATERIAL AND METHODS: An electronic literature search was conducted using the appropriate search terms, and the titles and abstracts were screened for relevance. The search yielded 13 hits after duplicates were removed, and four studies met the inclusion criteria for review. RESULTS: No studies to date have utilized XFEM to study cyclic fatigue or crack propagation in rotary endodontic NiTi instruments. Challenges such as modelling material inputs and fatigue criteria could explain the lack of utilization of XFEM in the analysis of mechanical behavior in NiTi instruments. CONCLUSIONS: The review showed that XFEM was seldom employed in endodontic literature. Recent work suggests potential promise in using XFEM for modelling NiTi structures.


Subject(s)
Endodontics , Finite Element Analysis , Nickel , Titanium , Humans , Dental Alloys/chemistry , Dental Instruments , Endodontics/instrumentation , Endodontics/methods , Materials Testing , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Stress, Mechanical
8.
Zhongguo Gu Shang ; 37(5): 505-15, 2024 May 25.
Article in Chinese | MEDLINE | ID: mdl-38778536

ABSTRACT

OBJECTIVE: To analyze the hip joint biomechanics of the acetabular anatomical reconstruction and nonanatomical reconstruction in total hip arthroplasty (THA) for Crowe type Ⅲ developmental dysplasia of the hip (DDH) by finite element method, which provided theoretical foundation and experimental basis for the anatomical acetabular reconstruction during THA in clinical practice. METHODS: One patient with left end-stage hip arthritis secondary to Crowe type Ⅲ DDH was selected in this study, who underwent total hip arthroplasty in the orthopedic department of the First Affiliated Hospital of Bengbu Medical College in April 2020. This patient was female, 57 years old. The preoperative and postoperative three dimentional CT scan of the patient's pelvis were performed. Fourteen acetabular cup models with different anteversion, inclination and rotation center height were established in Mimics and 3-Matic software. The boundary and load conditions were set in Abaqus software. The Von Mises and stress distribution of the hip joint were calculated and observed. RESULTS: In the Crowe type Ⅲ DDH THA, if the hip rotation center was restored anatomically and the acetabular cup's inclination was set as 40°, the cup's anteversion varied from 5° to 25°, the lowest Von Mises value of acetabular cup and polyethylene liner occured in 20°anteversioin;if the hip rotation center was restored anatomically and the acetabular cup's anteversion was set as 15°, the cup's inclination varied from 35° to 55°, the lowest Von Mises value of acetabular cup and polyethylene liner occured in 35° inclination;if the acetabular cup's anteversion and inclination were set as 15°and 40°respectively, the up migration of hip rotaion center varied from 0 mm to 20 mm, the lowest Von Mises value of acetabular cup and polyethylene liner occured in 10 mm up migration. In all fourteen models, the Von Mises value of the acetabulum, acetabulum cup and polyethylene liner were lowest when the acetabular cup's anteversion and inlcination were 15°, 35° respectively, as well as the rotation center was restored anatomically. CONCLUSION: In total hip arthroplasty for Crowe type Ⅲ DDH, the anatomical restoration of hip rotation center with 15° anteversion and 35° inclination of the acetabular cup are suggested, bone graft above the acetabular cup and additional screws are recommended simultaneously to further reduce the Von Mises of hip joint.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Developmental Dysplasia of the Hip , Finite Element Analysis , Humans , Arthroplasty, Replacement, Hip/methods , Female , Middle Aged , Biomechanical Phenomena , Acetabulum/surgery , Developmental Dysplasia of the Hip/surgery , Hip Joint/surgery , Hip Joint/physiopathology , Plastic Surgery Procedures/methods
9.
BMC Musculoskelet Disord ; 25(1): 400, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38773411

ABSTRACT

OBJECTIVE: Muscle dysfunction caused by repetitive work or strain in the neck region can interfere muscle responses. Muscle dysfunction can be an important factor in causing cervical spondylosis. However, there has been no research on how the biomechanical properties of the upper cervical spine change when the suboccipital muscle group experiences dysfunction. The objective of this study was to investigate the biomechanical evidence for cervical spondylosis by utilizing the finite element (FE) approach, thus and to provide guidance for clinicians performing acupoint therapy. METHODS: By varying the elastic modulus of the suboccipital muscle, the four FE models of C0-C3 motion segments were reconstructed under the conditions of normal muscle function and muscle dysfunction. For the two normal condition FE models, the elastic modulus for suboccipital muscles on both sides of the C0-C3 motion segments was equal and within the normal range In one muscle dysfunction FE model, the elastic modulus on both sides was equal and greater than 37 kPa, which represented muscle hypertonia; in the other, the elastic modulus of the left and right suboccipital muscles was different, indicating muscle imbalance. The biomechanical behavior of the lateral atlantoaxial joint (LAAJ), atlanto-odontoid joint (ADJ), and intervertebral disc (IVD) was analyzed by simulations, which were carried out under the six loadings of flexion, extension, left and right lateral bending, left and right axial rotation. RESULTS: Under flexion, the maximum stress in LAAJ with muscle imbalance was higher than that with normal muscle and hypertonia, while the maximum stress in IVD in the hypertonic model was higher than that in the normal and imbalance models. The maximum stress in ADJ was the largest under extension among all loadings for all models. Muscle imbalance and hypertonia did not cause overstress and stress distribution abnormalities in ADJ. CONCLUSION: Muscle dysfunction increases the stress in LAAJ and in IVD, but it does not affect ADJ.


Subject(s)
Cervical Vertebrae , Finite Element Analysis , Humans , Biomechanical Phenomena , Cervical Vertebrae/physiopathology , Spondylosis/physiopathology , Neck Muscles/physiopathology , Elastic Modulus , Range of Motion, Articular/physiology , Atlanto-Axial Joint/physiopathology , Muscle Hypertonia/physiopathology , Muscle Hypertonia/etiology
10.
PLoS One ; 19(5): e0303752, 2024.
Article in English | MEDLINE | ID: mdl-38753866

ABSTRACT

BACKGROUND: First metatarsophalangeal joint arthrodesis is a typical medical treatment performed in cases of arthritis or joint deformity. The gold standard for this procedure is arthrodesis stabilisation with the dorsally positioned plate. However, according to the authors' previous studies, medially positioned plate provides greater bending stiffness. It is worth to compare the mechanical conditions for bone formation in the fracture callus for both placements of the locking plate. METHODS: Two finite element models of the first metatarsophalangeal joint with the dorsally and medially positioned plate were defined in the Abaqus software to simulate differentiation of the fracture callus. A simplified load application, i.e. one single step per each day and the diffusion of the mesenchymal stem cells into the fracture region were assumed in an iterative hardening process. The changes of the mesenchymal stem cells into different phenotypes during the callus stiffening were governed by the octahedral shear strain and interstitial fluid velocity according to Prendergast mechanoregulation theory. Basing on the obtained results the progress of the cartilage and bone tissues formation and their distribution within the callus were compared between two models. FINDINGS: The obtained results suggest that after 6 weeks of simulation the healing progress is in general comparable for both plates. However, earlier closing of external callus was observed for the medially positioned plate which had greater vertical bending stiffness. This process enables faster internal callus hardening and promotes symmetrical bridging.


Subject(s)
Arthrodesis , Bone Plates , Finite Element Analysis , Metatarsophalangeal Joint , Arthrodesis/methods , Humans , Metatarsophalangeal Joint/surgery , Biomechanical Phenomena , Bony Callus , Fracture Healing
11.
Medicine (Baltimore) ; 103(20): e38258, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38758846

ABSTRACT

BACKGROUND: The aim of this study was to compare the biomechanical performance of pedicle screw construction and locking compression plate fixation in posterior pelvic ring injuries analyzed by finite element method. METHODS: A 3-dimensional finite element model of the spine-pelvis-femur complex with ligaments was reconstructed from computed tomography images. An unstable posterior pelvic ring injury was created, which was fixed with a pedicle screw construction or locking compression plate. A follower load of 400 N was applied to the upper surface of the vertebrae to simulate the upper body weight, while the ends of the proximal femurs were fixed. The construct stiffness, the maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum, and stress distributions of the implants and pelvises were assessed. RESULTS: The construct stiffness of the pedicle screw model (435.14 N/mm) was 2 times that of the plate model (217.01 N/mm). The maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum in the pedicle screw model were smaller than those in the plate model (0.919, 1.299, 0.259, and 1.413 mm in the pedicle screw model, and 1.843, 2.300, 1.053, and 2.895 mm in the plate model, respectively). The peak stresses of the implant and pelvis in the pedicle screw model decreased by 80.4% and 25% when compared with the plate model (44.57 and 34.48 MPa in the pedicle screw model, and 227.47 and 45.97 MPa in the plate model, respectively). CONCLUSION: The study suggested that the pedicle screw construction could provide better fixation stability than the locking compression plate and serves as the recommended fixation method for the treatment of posterior pelvic ring injuries.


Subject(s)
Bone Plates , Finite Element Analysis , Fracture Fixation, Internal , Pedicle Screws , Pelvic Bones , Humans , Pelvic Bones/injuries , Pelvic Bones/surgery , Biomechanical Phenomena , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Tomography, X-Ray Computed , Fractures, Bone/surgery
12.
PLoS One ; 19(5): e0303511, 2024.
Article in English | MEDLINE | ID: mdl-38743738

ABSTRACT

The brachial plexus is a set of nerves that innervate the upper extremity and may become injured during the birthing process through an injury known as Neonatal Brachial Plexus Palsy. Studying the mechanisms of these injuries on infant cadavers is challenging due to the justifiable sensitivity surrounding testing. Thus, these specimens are generally unavailable to be used to investigate variations in brachial plexus injury mechanisms. Finite Element Models are an alternative way to investigate the response of the neonatal brachial plexus to loading. Finite Element Models allow a virtual representation of the neonatal brachial plexus to be developed and analyzed with dimensions and mechanical properties determined from experimental studies. Using ABAQUS software, a two-dimensional brachial plexus model was created to analyze how stresses and strains develop within the brachial plexus. The main objectives of this study were (1) to develop a model of the brachial plexus and validate it against previous literature, and (2) to analyze the effect of stress on the nerve roots based on variations in the angles between the nerve roots and the spinal cord. The predicted stress for C5 and C6 was calculated as 0.246 MPa and 0.250 MPa, respectively. C5 and C6 nerve roots experience the highest stress and the largest displacement in comparison to the lower nerve roots, which correlates with clinical patterns of injury. Even small (+/- 3 and 6 degrees) variations in nerve root angle significantly impacted the stress at the proximal nerve root. This model is the first step towards developing a complete three-dimensional model of the neonatal brachial plexus to provide the opportunity to more accurately assess the effect of the birth process on the stretch within the brachial plexus and the impact of biological variations in structure and properties on the risk of Neonatal Brachial Plexus Palsy.


Subject(s)
Brachial Plexus , Finite Element Analysis , Brachial Plexus/injuries , Brachial Plexus/anatomy & histology , Humans , Infant, Newborn , Stress, Mechanical , Biomechanical Phenomena
13.
BMC Oral Health ; 24(1): 561, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38745284

ABSTRACT

BACKGROUND: Prefabricated myofunctional appliance can guide tooth eruption, improve dentition alignment, correct myofunctional disorders and harmful oral habits. However, its application to skeletal discrepancy may result in unsatisfactory tooth inclination. This study aimed to construct a novel appliance with overjet design to avoid this side effect and investigated its shape and mechanical changes under occlusion using three-dimensional finite element method. METHODS: We established three samples of prefabricated myofunctional appliances. The first one was edge to edge without overjet, and the outer shield of both jaws were flattened. The second one was 3 mm overjet with stepped the outer shield. The last one was 3 mm overjet, and the outer shield of both jaws were flatted, which meant the front wall of lower jaw was strengthened with bumper, termed as lower bumper. A complete dentition model was applied to the study. 150 N occlusal force was applied to each type of appliance and the deformation displacement and the changes in stress was recorded. RESULTS: The deformation was significant in the incisors regions, especially in the vertical and lateral dimensions. The maximum displacements of 3 mm overjet with step shield group were 7.08 mm (vertical), 3.99 mm (lateral), and 2.90 mm (sagittal), while it decreased to 3.92 mm(vertical), 1.94 mm (lateral), and 1.55 mm (sagittal) in overjet with bumper group. Moreover, the upper molar regions exhibited higher vertical and sagittal displacement in 3 mm overjet with step shield group, which were 3.03 mm (vertical) and 1.99 mm (sagittal), and the bumper design could decrease the maximum displacement to 1.72 mm (vertical) and 0.72 mm (sagittal). In addition, the Von Mises stress of appliances was analyzed, and results indicated that 3 mm overjet with step shield generated higher stress than other groups, with the maximum Von Mises stress was 0.9387 MP, which were 0.5858 and 0.5657 MP in edge to edge group and 3 mm overjet with lower bumper group, respectively. CONCLUSION: The prefabricated myofunctional appliances may cause deformation during occlusion. Compared to step shield group, the application of lower bumper exhibited better resistance to occlusal force.


Subject(s)
Finite Element Analysis , Orthodontic Appliance Design , Humans , Myofunctional Therapy/instrumentation , Myofunctional Therapy/methods , Bite Force , Imaging, Three-Dimensional/methods , Overbite/therapy , Stress, Mechanical , Mandible , Incisor , Biomechanical Phenomena
14.
Comput Biol Med ; 175: 108551, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38703546

ABSTRACT

The long-term performance of porous coated tibial implants for total ankle replacement (TAR) primarily depends on the extent of bone ingrowth at the bone-implant interface. Although attempts were made for primary fixation for immediate post-operative stability, no investigation was conducted on secondary fixation. The aim of this study is to assess bone ingrowth around the porous beaded coated tibial implant for TAR using a mechanoregulatory algorithm. A realistic macroscale finite element (FE) model of the implanted tibia was developed based on computer tomography (CT) data to assess implant-bone micromotions and coupled with microscale FE models of the implant-bone interface to predict bone ingrowth around tibial implant for TAR. The macroscale FE model was subjected to three near physiological loading conditions to evaluate the site-specific implant-bone micromotion, which were then incorporated into the corresponding microscale model to mimic the near physiological loading conditions. Results of the study demonstrated that the implant experienced tangential micromotion ranged from 0 to 71 µm with a mean of 3.871 µm. Tissue differentiation results revealed that bone ingrowth across the implant ranged from 44 to 96 %, with a mean of around 70 %. The average Young's modulus of the inter-bead tissue layer varied from 1444 to 4180 MPa around the different regions of the implant. The analysis postulates that when peak micromotion touches 30 µm around different regions of the implant, it leads to pronounced fibrous tissues on the implant surface. The highest amount of bone ingrowth was observed in the central regions, and poor bone ingrowth was seen in the anterior parts of the implant, which indicate improper osseointegration around this region. This macro-micro mechanical FE framework can be extended to improve the implant design to enhance the bone ingrowth and in future to develop porous lattice-structured implants to predict and enhance osseointegration around the implant.


Subject(s)
Algorithms , Arthroplasty, Replacement, Ankle , Finite Element Analysis , Tibia , Humans , Tibia/surgery , Tibia/diagnostic imaging , Arthroplasty, Replacement, Ankle/instrumentation , Tomography, X-Ray Computed , Models, Biological , Osseointegration/physiology , Bone-Implant Interface/diagnostic imaging , Joint Prosthesis
15.
Sci Rep ; 14(1): 10808, 2024 05 11.
Article in English | MEDLINE | ID: mdl-38734763

ABSTRACT

Finite element analysis (FEA) is commonly used in orthopaedic research to estimate localised tissue stresses and strains. A variety of boundary conditions have been proposed for isolated femur analysis, but it remains unclear how these assumed constraints influence FEA predictions of bone biomechanics. This study compared the femoral head deflection (FHD), stresses, and strains elicited under four commonly used boundary conditions (fixed knee, mid-shaft constraint, springs, and isostatic methods) and benchmarked these mechanics against the gold standard inertia relief method for normal and pathological femurs (extreme anteversion and retroversion, coxa vara, and coxa valga). Simulations were performed for the stance phase of walking with the applied femoral loading determined from patient-specific neuromusculoskeletal models. Due to unrealistic biomechanics observed for the commonly used boundary conditions, we propose a novel biomechanical constraint method to generate physiological femur biomechanics. The biomechanical method yielded FHD (< 1 mm), strains (approaching 1000 µÎµ), and stresses (< 60 MPa), which were consistent with physiological observations and similar to predictions from the inertia relief method (average coefficient of determination = 0.97, average normalized root mean square error = 0.17). Our results highlight the superior performance of the biomechanical method compared to current methods of constraint for  both healthy and pathological femurs.


Subject(s)
Femur , Finite Element Analysis , Gait , Stress, Mechanical , Humans , Femur/physiology , Gait/physiology , Biomechanical Phenomena , Male , Adult , Computer Simulation , Female
16.
Medicine (Baltimore) ; 103(19): e38065, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38728521

ABSTRACT

Knee varus (KV) deformity leads to abnormal forces in the different compartments of the joint cavity and abnormal mechanical loading thus leading to knee osteoarthritis (KOA). This study used computer-aided design to create 3-dimensional simulation models of KOA with varying varus angles to analyze stress distribution within the knee joint cavity using finite element analysis for different varus KOA models and to compare intra-articular loads among these models. Additionally, we developed a cartilage loading model of static KV deformity to correlate with dynamic clinical cases of cartilage injury. Different KV angle models were accurately simulated with computer-aided design, and the KV angles were divided into (0°, 3°, 6°, 9°, 12°, 15°, and 18°) 7 knee models, and then processed with finite element software, and the Von-Mises stress distribution and peak values of the cartilage of the femoral condyles, medial tibial plateau, and lateral plateau were obtained by simulating the human body weight in axial loading while performing the static extension position. Finally, intraoperative endoscopy visualization of cartilage injuries in clinical cases corresponding to KV deformity subgroups was combined to find cartilage loading and injury correlations. With increasing varus angle, there was a significant increase in lower limb mechanical axial inward excursion and peak Von-Mises stress in the medial interstitial compartment. Analysis of patients' clinical data demonstrated a significant correlation between varus deformity angle and cartilage damage in the knee, medial plateau, and patellofemoral intercompartment. Larger varus deformity angles could be associated with higher medial cartilage stress loads and increased cartilage damage in the corresponding peak stress area. When the varus angle exceeds 6°, there is an increased risk of cartilage damage, emphasizing the importance of early surgical correction to prevent further deformity and restore knee function.


Subject(s)
Cartilage, Articular , Finite Element Analysis , Knee Joint , Osteoarthritis, Knee , Humans , Osteoarthritis, Knee/physiopathology , Osteoarthritis, Knee/surgery , Cartilage, Articular/diagnostic imaging , Cartilage, Articular/pathology , Knee Joint/physiopathology , Male , Weight-Bearing/physiology , Biomechanical Phenomena , Middle Aged , Stress, Mechanical , Female , Computer Simulation , Aged
17.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241251926, 2024.
Article in English | MEDLINE | ID: mdl-38733065

ABSTRACT

AIM: To explore the effects of tibial osteotomy varus angle combined with posterior tibial slope (PTS) on the stress of polyethylene liner in total knee arthroplasty (TKA) by building finite element model (FEM). METHODS: Established the FEM of standard TKA with tibial osteotomy varus angle 0° to 9° were established and divided into 10 groups. Next, each group was created 10 FEMs with 0° to 9° PTS separately. Calculated the stress on polyethylene liner in each group in Abaqus. Finally, the relevancy between tibial osteotomy angle and polyethylene liner stress was statistically analyzed using multiple regression analysis. RESULTS: As the varus angle increased, the area of maximum stress gradually shifted medially on the polyethylene liner. As the PTS increases, the percentage of surface contact forces on the medial and lateral compartmental of the polyethylene liner gradually converge to the same. When the varus angle is between 0° and 3°, the maximum stress of the medial compartmental surfaces of polyethylene liner rises smoothly with the increase of the PTS. When the varus angle is between 4° and 9°, as the increase of the PTS, the maximum stress of polyethylene liner rises first and then falls, forming a trough at PTS 5° and then rises again. Compared to the PTS, the varus angle has a large effect on the maximum stress of the polyethylene liner (p < .001). CONCLUSION: When the varus angle is 0° to 3°, PTS 0° is recommended, which will result in a more equalized stress distribution of the polyethylene liner in TKA.


Subject(s)
Arthroplasty, Replacement, Knee , Finite Element Analysis , Knee Prosthesis , Osteotomy , Polyethylene , Stress, Mechanical , Tibia , Humans , Arthroplasty, Replacement, Knee/methods , Osteotomy/methods , Tibia/surgery , Prosthesis Design
18.
J Biomed Mater Res B Appl Biomater ; 112(5): e35417, 2024 May.
Article in English | MEDLINE | ID: mdl-38742468

ABSTRACT

Stress shielding is one of the major concerns for total ankle replacement implants nowadays, because it is responsible for implant-induced bone resorption. The bone resorption contributes to the aseptic loosening and failure of ankle implants in later stages. To reduce the stress shielding, improvements can be made in the implant material by decreasing the elastic mismatch between the implant and the tibia bone. This study proposes a new functionally graded material (FGM) based tibial implant for minimizing the problem of stress shielding. Three-dimensional finite element (FE) models of the intact tibia and the implanted tibiae were created to study the influence of material gradation law and volume fraction index on stress shielding and implant-bone micromotion. Different implant materials were considered that is, cobalt-chromium, titanium (Ti), and FGM with Ti at the bottom and hydroxyapatite (HA) at the top. The FE models of FGM implants were generated by using different volume fractions and the rule of mixtures. The rule of mixtures was used to calculate the FGM properties based on the local volume fraction. The volume fraction was defined by using exponential, power, and sigmoid laws. For the power and sigmoid law varying volume fraction indices (0.1, 0.2, 0.5, 1, 2, and 5) were considered. The geometry resembling STAR® ankle system tibial implant was considered for the present study. The results indicate that FGMs lower stress shielding but also marginally increase implant-bone micromotion; however, the values were within the acceptable limit for bone ingrowth. It is observed that the material gradation law and volume fraction index influence the performance of FGM tibial implants. The tibial implant composed of FGM using power law with a volume fraction index of 0.1 was the preferred option because it showed the least stress shielding.


Subject(s)
Arthroplasty, Replacement, Ankle , Finite Element Analysis , Tibia , Titanium , Titanium/chemistry , Humans , Durapatite/chemistry , Prosthesis Design , Stress, Mechanical , Materials Testing
19.
J Orthop Surg Res ; 19(1): 290, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38735949

ABSTRACT

BACKGROUND: As an innovative internal fixation system, FNS (femoral neck system) is increasingly being utilized by surgeons for the treatment of femoral neck fractures. At present, there have been numerous finite element analysis experiments studying the immediate stability of FNS and CSS in treating femoral neck fractures. However, there is scarce mechanical analysis available regarding the effects post internal fixation removal. This study aimed to investigate the alterations in mechanical parameters of the proximal femur before and after the removal of FNS (femoral neck system), and to assess potential distinctions in indicators following the extraction of CSS (Cannulated Screws). METHODS: A proximal femur model was reconstructed using finite element numerical techniques. The models for CSS and FNS were formulated utilizing characteristics and parametric definitions. The internal fixation was combined with a normal proximal femur model to simulate the healing state after fracture surgery. Within the framework of static analysis, consistent stress burdens were applied across the entirety of the models. The total deformation and equivalent stress of the proximal femur were recorded before and after the removal of internal fixation. RESULTS: Under the standing condition, the total deformation of the model before and after removing CSS was 0.99 mm and 1.10 mm, respectively, indicating an increase of 12%. The total deformation of the model before and after removing FNS was 0.65 mm and 0.76 mm, respectively, indicating an increase of 17%. The equivalent stress for CSS and FNS were 55.21 MPa and 250.67 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of CSS was 7.76 MPa and 6.11 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of FNS was 9.89 MPa and 8.79 MPa, respectively. CONCLUSIONS: The retention of internal fixation may contribute to improved stability of the proximal femur. However, there still existed risks of stress concentration in internal fixation and stress shielding in the proximal femur. Compared to CSS, the removal of FNS results in larger bone tunnels and insufficient model stability. Further clinical interventions are recommended to address this issue.


Subject(s)
Bone Screws , Femoral Neck Fractures , Finite Element Analysis , Fracture Fixation, Internal , Humans , Biomechanical Phenomena , Femoral Neck Fractures/surgery , Fracture Fixation, Internal/methods , Femur Neck/surgery , Femur Neck/diagnostic imaging , Femur/surgery , Stress, Mechanical , Device Removal/methods
20.
ACS Biomater Sci Eng ; 10(5): 2863-2879, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38696332

ABSTRACT

The present work describes a preclinical trial (in silico, in vivo and in vitro) protocol to assess the biomechanical performance and osteogenic capability of 3D-printed polymeric scaffolds implants used to repair partial defects in a sheep mandible. The protocol spans multiple steps of the medical device development pipeline, including initial concept design of the scaffold implant, digital twin in silico finite element modeling, manufacturing of the device prototype, in vivo device implantation, and in vitro laboratory mechanical testing. First, a patient-specific one-body scaffold implant used for reconstructing a critical-sized defect along the lower border of the sheep mandible ramus was designed using on computed-tomographic (CT) imagery and computer-aided design software. Next, the biomechanical performance of the implant was predicted numerically by simulating physiological load conditions in a digital twin in silico finite element model of the sheep mandible. This allowed for possible redesigning of the implant prior to commencing in vivo experimentation. Then, two types of polymeric biomaterials were used to manufacture the mandibular scaffold implants: poly ether ether ketone (PEEK) and poly ether ketone (PEK) printed with fused deposition modeling (FDM) and selective laser sintering (SLS), respectively. Then, after being implanted for 13 weeks in vivo, the implant and surrounding bone tissue was harvested and microCT scanned to visualize and quantify neo-tissue formation in the porous space of the scaffold. Finally, the implant and local bone tissue was assessed by in vitro laboratory mechanical testing to quantify the osteointegration. The protocol consists of six component procedures: (i) scaffold design and finite element analysis to predict its biomechanical response, (ii) scaffold fabrication with FDM and SLS 3D printing, (iii) surface treatment of the scaffold with plasma immersion ion implantation (PIII) techniques, (iv) ovine mandibular implantation, (v) postoperative sheep recovery, euthanasia, and harvesting of the scaffold and surrounding host bone, microCT scanning, and (vi) in vitro laboratory mechanical tests of the harvested scaffolds. The results of microCT imagery and 3-point mechanical bend testing demonstrate that PIII-SLS-PEK is a promising biomaterial for the manufacturing of scaffold implants to enhance the bone-scaffold contact and bone ingrowth in porous scaffold implants. MicroCT images of the harvested implant and surrounding bone tissue showed encouraging new bone growth at the scaffold-bone interface and inside the porous network of the lattice structure of the SLS-PEK scaffolds.


Subject(s)
Biocompatible Materials , Mandible , Tissue Scaffolds , Animals , Sheep , Mandible/surgery , Mandible/diagnostic imaging , Tissue Scaffolds/chemistry , Printing, Three-Dimensional , Finite Element Analysis , Osteogenesis
SELECTION OF CITATIONS
SEARCH DETAIL
...