1.
Neurology ; 83(3): 221-6, 2014 Jul 15.
Article in English | MEDLINE | ID: mdl-24928123

ABSTRACT

OBJECTIVE: To examine predictors of stroke recurrence in patients with a high vs a low likelihood of having an incidental patent foramen ovale (PFO) as defined by the Risk of Paradoxical Embolism (RoPE) score. METHODS: Patients in the RoPE database with cryptogenic stroke (CS) and PFO were classified as having a probable PFO-related stroke (RoPE score of >6, n = 647) and others (RoPE score of ≤6 points, n = 677). We tested 15 clinical, 5 radiologic, and 3 echocardiographic variables for associations with stroke recurrence using Cox survival models with component database as a stratification factor. An interaction with RoPE score was checked for the variables that were significant. RESULTS: Follow-up was available for 92%, 79%, and 57% at 1, 2, and 3 years. Overall, a higher recurrence risk was associated with an index TIA. For all other predictors, effects were significantly different in the 2 RoPE score categories. For the low RoPE score group, but not the high RoPE score group, older age and antiplatelet (vs warfarin) treatment predicted recurrence. Conversely, echocardiographic features (septal hypermobility and a small shunt) and a prior (clinical) stroke/TIA were significant predictors in the high but not low RoPE score group. CONCLUSION: Predictors of recurrence differ when PFO relatedness is classified by the RoPE score, suggesting that patients with CS and PFO form a heterogeneous group with different stroke mechanisms. Echocardiographic features were only associated with recurrence in the high RoPE score group.


Subject(s)
Embolism, Paradoxical/epidemiology , Foramen Ovale, Patent/epidemiology , Ischemic Attack, Transient/epidemiology , Stroke/epidemiology , Adult , Aged , Comorbidity , Databases, Factual , Female , Follow-Up Studies , Foramen Ovale, Patent/classification , Foramen Ovale, Patent/diagnosis , Humans , Ischemic Attack, Transient/drug therapy , Male , Middle Aged , Predictive Value of Tests , Proportional Hazards Models , Recurrence , Risk Assessment , Stroke/drug therapy
3.
Minerva Cardioangiol ; 57(3): 275-84, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19513008

ABSTRACT

AIM: The aim of this study was to describe and classify the various anatomical pattern of patent foramen ovale (PFO) with transesophageal echocardiography (TEE) and to relate such classification to the selection of PFO closure devices. METHODS: This study enrolled 216 PFO patients (118 females) mostly with previous cryptogenic stroke or transitory ischemic attack (TIA) who underwent percutaneous closure of PFO with deep sedation under TEE control. Anatomical patterns were classified as follows: simple: PFO characterised by central/superior eccentric shunt or with a valve mechanism (45%); reduse: widely redundant septum primum (22%); ASA: atrial septal aneurysm (11%); EASA: entire atrial septal aneurysm (1.4%); CRIB: cribriform septum primum (9%); tunnel: tunnel between septum primum and secundum >10 mm (11%). Degree of right-to-left shunt, either at basal condition or at Valsalva manoeuvre, was classified as: 1=mild (45%); 2=moderate (42%); 3=severe (13%). Additional right-atrium anatomical features are also described. RESULTS: Procedure was successful in 100% of the cases. At follow-up recurrent TIA occurred in two patients. Residual shunts were present in 4.9% of the patients after Valsalva manoeuvre. Palpitations were reported in 4%. CONCLUSIONS: Closing the PFO choosing the device following strict anatomical criteria based on TEE assessment allowed excellent immediate and late results minimizing residual shunts.


Subject(s)
Balloon Occlusion , Cardiac Catheterization , Foramen Ovale, Patent/pathology , Foramen Ovale, Patent/therapy , Adult , Aged , Balloon Occlusion/methods , Cardiac Catheterization/methods , Echocardiography, Transesophageal , Female , Follow-Up Studies , Foramen Ovale, Patent/classification , Foramen Ovale, Patent/diagnosis , Foramen Ovale, Patent/diagnostic imaging , Humans , Italy , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Risk Assessment , Severity of Illness Index , Treatment Outcome , Ultrasonography, Doppler, Color
4.
J Neuroimaging ; 18(4): 402-6, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18333839

ABSTRACT

BACKGROUND: International Consensus Criteria (ICC) consider right-to-left shunt (RLS) present when Transcranial Doppler (TCD) detects even one microbubble (microB). Spencer Logarithmic Scale (SLS) offers more grades of RLS with detection of >30 microB corresponding to a large shunt. We compared the yield of ICC and SLS in detection and quantification of a large RLS. SUBJECTS AND METHODS: We prospectively evaluated paradoxical embolism in consecutive patients with ischemic strokes or transient ischemic attack (TIA) using injections of 9 cc saline agitated with 1 cc of air. Results were classified according to ICC [negative (no microB), grade I (1-20 microB), grade II (>20 microB or "shower" appearance of microB), and grade III ("curtain" appearance of microB)] and SLS criteria [negative (no microB), grade I (1-10 microB), grade II (11-30 microB), grade III (31100 microB), grade IV (101300 microB), grade V (>300 microB)]. The RLS size was defined as large (>4 mm) using diameter measurement of the septal defects on transesophageal echocardiography (TEE). RESULTS: TCD comparison to TEE showed 24 true positive, 48 true negative, 4 false positive, and 2 false negative cases (sensitivity 92.3%, specificity 92.3%, positive predictive value (PPV) 85.7%, negative predictive value (NPV) 96%, and accuracy 92.3%) for any RLS presence. Both ICC and SLS were 100% sensitive for detection of large RLS. ICC and SLS criteria yielded a false positive rate of 24.4% and 7.7%, respectively when compared to TEE. CONCLUSIONS: Although both grading scales provide agreement as to any shunt presence, using the Spencer Scale grade III or higher can decrease by one-half the number of false positive TCD diagnoses to predict large RLS on TEE.


Subject(s)
Cerebral Infarction/diagnostic imaging , Consensus , Echocardiography, Transesophageal , Embolism, Paradoxical/diagnostic imaging , Foramen Ovale, Patent/diagnostic imaging , Image Processing, Computer-Assisted , Ischemic Attack, Transient/diagnostic imaging , Ultrasonography, Doppler, Transcranial , Adult , Aged , Cerebral Infarction/classification , Contrast Media , Embolism, Paradoxical/classification , Female , Foramen Ovale, Patent/classification , Humans , Ischemic Attack, Transient/classification , Male , Microbubbles , Middle Aged , ROC Curve , Sensitivity and Specificity , Sodium Chloride , Ultrasonography, Doppler, Transcranial/classification