Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44.961
Filter
2.
J Orthop Surg Res ; 19(1): 327, 2024 Jun 02.
Article in English | MEDLINE | ID: mdl-38825673

ABSTRACT

BACKGROUND: Ankle fractures are frequent, and despite numerous publications on their treatment and outcome, there is a lack of precise data on the functional results in young, healthy and physically active patients. We hypothesized that patients who underwent open reduction and internal fixation (ORIF) for simple ankle fractures would have similar function compared to a healthy control group, whereas patients with complex fractures will have significant functional deficits. Furthermore, we postulate that there is a discrepancy between the radiological and the functional outcomes. METHODS: A set of specific provocation tests was developed to evaluate the postoperative possibility of weight bearing, stop-and-go activities and range of motion. In combination with three questionnaires and a radiographic evaluation, the true functional outcome and the possibility of participating in sporting activities were investigated and compared with those of an age- and sex-matched control group. RESULTS: A significant impairment was found in unilateral and simple ankle fractures. This impairment increased in tests including stop-and-go activities in combination with load bearing and with the complexity of the fractures. Concerning the subjective outcome, there was a significant adverse effect for daily activities without any difference in preoperative or postoperative sporting activity between the groups. No difference was found in the radiological assessment. CONCLUSIONS: Both simple and complex ankle fractures treated with ORIF have a significant and long-lasting impact on functional outcome in young and active patients. The radiological result is not associated with a good functional outcome. TRIAL REGISTRATION: BASEC-Nr. 2018 - 01124.


Subject(s)
Ankle Fractures , Fracture Fixation, Internal , Humans , Female , Ankle Fractures/surgery , Ankle Fractures/diagnostic imaging , Male , Fracture Fixation, Internal/methods , Adult , Middle Aged , Treatment Outcome , Radiography , Weight-Bearing , Young Adult , Range of Motion, Articular , Recovery of Function , Aged
3.
Clin Orthop Surg ; 16(3): 493-505, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38827752

ABSTRACT

Background: Distal metaphyseal-diaphyseal junction fractures of the humerus are a subset of injuries between humeral shaft fractures and distal intra-articular humerus fractures. A lack of space for distal fixation and the unique anatomy of concave curvature create difficulties during operative treatment. The closely lying radial nerve is another major concern. The aim of this study was to determine whether anterolateral dual plate fixation could be effective for a distal junctional fracture of the humerus both biomechanically and clinically. Methods: A right humerus 3-dimensional (3D) model was obtained based on plain radiographs and computed tomography data of patients. Two fractures, a spiral type and a spiral wedge type, were constructed. Three-dimensional models of locking compression plates and screws were constructed using materials provided by the manufacturer. The experiment was conducted by using COMSOL Multiphysics, a finite element analysis, solver, and simulation software package. For the clinical study, from July 2008 to March 2021, a total of 72 patients were included. Their medical records were retrospectively reviewed to obtain patient demographics, elbow range of motion, Disabilities of the Arm, Shoulder and Hand (DASH) scores, Mayo Elbow Performance Scores (MEPS), and hand grip strength. Results: No fracture fixation construct completely restored stiffness comparable to the intact model in torsion or compression. Combinations of the 7-hole and 5-hole plates and the 8-hole and 6-hole plates showed superior structural stiffness and stress than those with single lateral plates. At least 3 screws (6 cortices) should be inserted into the lateral plate to reduce the load effectively. For the anterior plate, it was sufficient to purchase only the near cortex. Regarding clinical results of the surgery, the range of motion showed satisfactory results in elbow flexion, elbow extension, and forearm rotation. The average DASH score was 4.3 and the average MEPS was 88.2. Conclusions: Anterolateral dual plate fixation was biomechanically superior to the single-plate method in the finite element analysis of a distal junctional fracture of the humerus model. Anterolateral dual plate fixation was also clinically effective in a large cohort of patients with distal junctional fractures of the humerus.


Subject(s)
Bone Plates , Finite Element Analysis , Fracture Fixation, Internal , Humeral Fractures , Humans , Humeral Fractures/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Male , Middle Aged , Female , Adult , Retrospective Studies , Biomechanical Phenomena , Aged , Range of Motion, Articular , Humerus/surgery
4.
Clin Orthop Surg ; 16(3): 470-476, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38827753

ABSTRACT

Background: This study aims to report the midterm outcomes after surgical treatment of Hawkins Classification III Talar neck fractures. Methods: From March 2010 to April 2022, among a total of 155 patients who visited our hospital with talus fractures, 31 patients underwent surgical treatment for Hawkins classification III talar neck fractures. The inclusion criteria comprised patients with a symptom duration of over 1 year who were available for outpatient follow-up and underwent magnetic resonance imaging (MRI) follow-up 2 months after surgery. Exclusion criteria included patients without preoperative ankle periarticular arthritis, and a total of 27 patients were enrolled. Traffic accidents and falls accounted for 86% of 23 cases, open fractures were 8 cases, and the mean follow-up period was 34.10 months (range, 12-80 months). Clinical outcomes were measured by American Orthopaedic Foot and Ankle Society (AOFAS) score and Foot function index (FFI), and radiological results were obtained using simple radiographs before and after surgery and MRI at 2 months postoperatively to confirm bone union and complications. Results: Complete bone union was achieved in all cases, and the mean duration of union was 4.9 months (range, 4-6 months) and there were no nonunion and varus malunion. At the final follow-up, the mean AOFAS score was 80.18 points (range, 36-90 points) and the mean FFI score was 31.43 points (range, 10-68 points), showing relatively good clinical outcomes. There were 15 cases of avascular necrosis, 6 cases of traumatic arthritis of the ankle joint, 6 cases of irritation of the posterior tibial nerve, and 4 cases of wound problems. Conclusions: Hawkins classification III talar neck fractures are mostly caused by high-energy injuries and have a relatively poor prognosis due to the high incidence of complications such as avascular necrosis or posttraumatic arthritis. However, if correct anatomical reduction and rigid internal fixation are performed within a short time after the injury, good results can be expected.


Subject(s)
Fracture Fixation, Internal , Fractures, Bone , Talus , Humans , Talus/surgery , Talus/injuries , Talus/diagnostic imaging , Male , Female , Adult , Middle Aged , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging , Young Adult , Aged , Retrospective Studies , Treatment Outcome , Adolescent , Magnetic Resonance Imaging
5.
Clin Orthop Surg ; 16(3): 357-362, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38827765

ABSTRACT

Background: Treatment of comminuted patellar fractures accompanied by coronal split articular and inferior pole fragments is a challenge. To treat this difficult fracture, we perform articular fragment detachment and separate fixation for coronal split articular and inferior pole fragments. We aimed to evaluate the radiological and clinical outcomes of our technique in comminuted patellar fractures at least 1 year after surgery. Methods: Between January 2019 and June 2022, 15 patients diagnosed with comminuted patellar fractures accompanied by coronal split articular and inferior pole fragments based on preoperative computed tomography underwent surgery using the articular detachment technique. The key point of this technique was anatomical reduction and subchondral fixation of the coronal split articular fragment to the superior main fragment after complete detachment of the coronal split fragment from the inferior pole. The remaining inferior pole was fixed using a separate construct. Postoperative articular gap, articular step-off, and complications, including resorption, reduction loss, and avascular necrosis of fixed articular fragments, were evaluated as radiological outcomes. Range of motion and the Lysholm scores were used to evaluate clinical outcomes. Results: Among the 15 patients, the coronal split articular fragments were fixed using Kirschner wires in 13 patients and headless screws in 2 patients. The inferior poles were fixed using separate vertical wiring in 13 patients and tension-band wiring in 2 patients. A postoperative articular gap was noted in 7 patients, with an average articular gap of 1.0 mm (range, 0.7-1.6 mm). No articular step-off was observed. Bone union and normal range of motion were achieved in all patients. On the 1-year postoperative lateral radiograph, resorption of the articular fracture site was seen in 5 patients. There was no loss of reduction or avascular necrosis of the coronal split articular fragments. The average postoperative Lysholm score at 1 year was 89.3 ± 4.1 (range, 82-95). Conclusions: The technique would be a reliable and safe option for the surgical treatment of comminuted patellar fractures accompanied by coronal split articular and inferior pole fragments in terms of anatomical reduction and stable fixation of articular fragments without risk of avascular necrosis.


Subject(s)
Fracture Fixation, Internal , Fractures, Comminuted , Patella , Humans , Fractures, Comminuted/surgery , Patella/surgery , Patella/injuries , Male , Female , Adult , Fracture Fixation, Internal/methods , Middle Aged , Bone Wires , Retrospective Studies , Tomography, X-Ray Computed , Young Adult , Bone Screws , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging
6.
PLoS One ; 19(6): e0300256, 2024.
Article in English | MEDLINE | ID: mdl-38829845

ABSTRACT

PURPOSE: Due to the increase in life expectancy and high-energy traumas, anterior column acetabular fractures (ACFs) are also increasing. While open reduction and internal fixation (ORIF) is still the standard surgical procedure, minimally invasive, percutaneous fixation of osteoporotic acetabulum fractures (AF) are growing in popularity. The aim of this biomechanical study was to evaluate the biomechanical competence following antegrade fixation with a standard screw versus a cannulated compression headless screw. METHODS: Eight anatomical osteoporotic composite pelvises were given an anterior column fracture. Two groups of eight specimens each (n = 8) for fixation with either a 6.5 mm cannulated compression headless screw in group Anterior Acetabulum Canulated Compression Headless Screw (AACCH), or with a 6.5 mm partially threaded cannulated screw in group Anterior Acetabulum Standard Screw (AASS) where compared. Each specimen was biomechanically loaded cyclically at a rate of 2 Hz with monotonically increasing compressive load until failure. Motions were assessed by means of optical motion tracking. RESULTS: Initial construct stiffness trended higher in group AACCH at 152.4 ± 23.1 N/mm compared to group AASS at 118.5 ± 34.3 N/mm, p = 0.051. Numbers of cycles and corresponding peak load at failure, were significantly higher in group AACCH at 6734 ± 1669 cycles and 873.4 ± 166.9 N versus group AASS at 4440 ± 2063 cycles and 644.0 ± 206.3 N, p = 0.041. Failure modes were breakout of the screws around the proximal entry point. CONCLUSION: From a biomechanical perspective, group AACCH was associated with superior biomechanical competence compared to standard partially threaded cannulated screws and could therefore be considered as valid alternative for fixation of anterior acetabulum fractures.


Subject(s)
Acetabulum , Bone Screws , Fracture Fixation, Internal , Acetabulum/surgery , Acetabulum/injuries , Humans , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Biomechanical Phenomena , Fractures, Bone/surgery , Osteoporosis/surgery , Osteoporosis/physiopathology , Osteoporosis/complications
7.
J Feline Med Surg ; 26(5): 1098612X241243134, 2024 May.
Article in English | MEDLINE | ID: mdl-38717791

ABSTRACT

CASE SERIES SUMMARY: A total of 13 cases of cats with a caudal mandibular fracture treated with a novel surgical technique using the Ramus Anatomical Plate system were reviewed. Preoperative, immediate postoperative and a minimum of 8 weeks postoperative CT images were required as inclusion criteria. The outcome and complications were determined from clinical data and radiographic follow-up examinations. All cases achieved adequate anatomical reduction, resulting in a functional and atraumatic occlusion postoperatively. No intraoperative complications were reported. Time to voluntary food intake was in the range of 1-25 days. No evidence of disruptions to the implants or screw loosening was observed in the 8-week postoperative CT imaging, with radiographic evidence of complete osseous union in all fractures. The most common postoperative complication was swelling at the surgical site. Two cats had postoperative exophthalmos due to retrobulbar haemorrhage, and one cat exhibited partial wound dehiscence 5 days postoperatively, which resolved with medical management. Longer-term complications included intraoral plate exposure in one cat, which required plate removal 10 months postoperatively. RELEVANCE AND NOVEL INFORMATION: In this case series, rigid internal fixation of caudal mandibular fractures using the Ramus Anatomical Plate osteosynthesis system was associated with a minimal complication rate, and satisfactory radiographic and clinical outcomes. The reported outcomes of this novel technique are favourable when compared with previous techniques described for the management of these fracture types.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Mandibular Fractures , Cats/injuries , Animals , Bone Plates/veterinary , Fracture Fixation, Internal/veterinary , Fracture Fixation, Internal/methods , Mandibular Fractures/veterinary , Mandibular Fractures/surgery , Male , Female , Treatment Outcome , Postoperative Complications/veterinary , Tomography, X-Ray Computed/veterinary , Cat Diseases/surgery
8.
J Int Med Res ; 52(5): 3000605241238983, 2024 May.
Article in English | MEDLINE | ID: mdl-38729774

ABSTRACT

OBJECTIVE: This study was performed to evaluate the mid-term clinical efficacy of the Femoral Neck System (FNS) (DePuy Synthes, Zuchwil, Switzerland) in treating young patients with unstable Pauwels type III femoral neck fractures. METHODS: We performed a retrospective observational analysis of 21 young adults treated with the FNS. Clinical outcomes were assessed based on fracture reduction quality, Harris hip scores, and postoperative complication rates. RESULTS: The study comprised 21 patients with a mean age of 35 years (range, 20-50 years) who were followed for a mean duration of 22.8 months (range, 16-30 months). Closed reduction was unfeasible in three (14.3%) patients, each of whom required open reduction. Notable postoperative complications were avascular necrosis in two (9.5%) patients, nonunion in one (4.7%), and implant failure in one (4.7%). Each of these complications led to the requirement for total hip arthroplasty. CONCLUSION: The favorable mid-term clinical outcomes of this study indicate that the FNS is a potentially effective treatment modality for young individuals with unstable Pauwels type III femoral neck fractures.


Subject(s)
Femoral Neck Fractures , Fracture Fixation, Internal , Humans , Femoral Neck Fractures/surgery , Male , Female , Adult , Retrospective Studies , Young Adult , Middle Aged , Treatment Outcome , Fracture Fixation, Internal/methods , Postoperative Complications/etiology , Femur Neck/surgery , Femur Head Necrosis/surgery , Femur Head Necrosis/etiology
9.
J Orthop Surg Res ; 19(1): 290, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38735949

ABSTRACT

BACKGROUND: As an innovative internal fixation system, FNS (femoral neck system) is increasingly being utilized by surgeons for the treatment of femoral neck fractures. At present, there have been numerous finite element analysis experiments studying the immediate stability of FNS and CSS in treating femoral neck fractures. However, there is scarce mechanical analysis available regarding the effects post internal fixation removal. This study aimed to investigate the alterations in mechanical parameters of the proximal femur before and after the removal of FNS (femoral neck system), and to assess potential distinctions in indicators following the extraction of CSS (Cannulated Screws). METHODS: A proximal femur model was reconstructed using finite element numerical techniques. The models for CSS and FNS were formulated utilizing characteristics and parametric definitions. The internal fixation was combined with a normal proximal femur model to simulate the healing state after fracture surgery. Within the framework of static analysis, consistent stress burdens were applied across the entirety of the models. The total deformation and equivalent stress of the proximal femur were recorded before and after the removal of internal fixation. RESULTS: Under the standing condition, the total deformation of the model before and after removing CSS was 0.99 mm and 1.10 mm, respectively, indicating an increase of 12%. The total deformation of the model before and after removing FNS was 0.65 mm and 0.76 mm, respectively, indicating an increase of 17%. The equivalent stress for CSS and FNS were 55.21 MPa and 250.67 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of CSS was 7.76 MPa and 6.11 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of FNS was 9.89 MPa and 8.79 MPa, respectively. CONCLUSIONS: The retention of internal fixation may contribute to improved stability of the proximal femur. However, there still existed risks of stress concentration in internal fixation and stress shielding in the proximal femur. Compared to CSS, the removal of FNS results in larger bone tunnels and insufficient model stability. Further clinical interventions are recommended to address this issue.


Subject(s)
Bone Screws , Femoral Neck Fractures , Finite Element Analysis , Fracture Fixation, Internal , Humans , Biomechanical Phenomena , Femoral Neck Fractures/surgery , Fracture Fixation, Internal/methods , Femur Neck/surgery , Femur Neck/diagnostic imaging , Femur/surgery , Stress, Mechanical , Device Removal/methods
10.
J Med Case Rep ; 18(1): 240, 2024 May 11.
Article in English | MEDLINE | ID: mdl-38730409

ABSTRACT

BACKGROUND: People with achondroplasia exhibit distinct physical characteristics, but their cognitive abilities remain within the normal range. The challenges encountered during surgical procedures and perioperative care for achondroplastic individuals, are underrepresented in the existing literature. CASE PRESENTATION: In this report, the management of a 26-year-old North-African achondroplastic male is highlighted. The patient suffered a complete intra-articular distal femur fracture (AO/OTA 33-C1) and an ipsilateral patella fracture (AO/OTA 34-C1). The patient's unusual anatomical variations and the lack of suitable orthopedic implants posed significant surgical challenges, particularly in the context of a resource-limited developing country. Facial and spinal deformities, which are common in patients with achondroplasia, further complicated the anesthetic approach. CONCLUSIONS: The limited information on operative management of fractures in achondroplastic patients necessitated independent decision-making and diverging from the convenient approach where clear guidance is available in the literature.


Subject(s)
Achondroplasia , Femoral Fractures , Patella , Humans , Adult , Male , Achondroplasia/complications , Femoral Fractures/surgery , Femoral Fractures/diagnostic imaging , Patella/injuries , Patella/surgery , Patella/diagnostic imaging , Intra-Articular Fractures/surgery , Intra-Articular Fractures/diagnostic imaging , Fracture Fixation, Internal/methods
11.
BMC Musculoskelet Disord ; 25(1): 368, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730497

ABSTRACT

BACKGROUND: This systemic review and meta-analysis aimed to evaluate the clinical outcomes of proximal humeral fracture in elderly patient fixation using locked plate with or without cement augmentation. METHODS: The databases of PubMed, Embase, and Cochrane Library were searched in August 2023 for literature comparing the clinical outcomes of patients with PHFs treated with locked plate alone and locked plate augmented with cement. Data describing study design; level of evidence; inclusion criteria; demographic information; final follow-up; revision rate; implant failure rate; avascular necrosis rate; total complication rate; constant score; and disability of arm, shoulder, and hand (DASH) score were collected. RESULTS: Eight studies (one randomized-controlled trial and seven observational studies), involving 664 patients, were identified. Compared with locked plates alone, using cement-augmented locked plates reduced the implant failure rate (odds ratio (OR) = 0.19; 95% confidence interval (CI) 0.10-0.39; P < 0.0001) and total complication rate (OR = 0.45; 95% CI 0.29-0.69; P = 0.0002) and improved DASH scores (mean difference (MD) = 2.99; 95% CI 1.00-4.98; P = 0.003). However, there was no significant difference in clinical outcomes, including revision rate, avascular necrosis rate, and constant score. CONCLUSION: In this review and meta-analysis, fixation of the PHFs in elderly patients using locked plates with or without cement augmentation has no significant difference in revision rate, but the implant failure and total complication rates may be lesser on using the cement-augmented locked plate for fixation than on using a locked plate alone. Good results are expected for most patients treated with this technique. TRIAL REGISTRATION: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)21 guidelines were followed to conduct this systematic review and meta-analysis and was registered as a protocol in PROSPERO (CRD42022318798).


Subject(s)
Bone Cements , Bone Plates , Fracture Fixation, Internal , Shoulder Fractures , Humans , Shoulder Fractures/surgery , Shoulder Fractures/diagnostic imaging , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/adverse effects , Bone Cements/therapeutic use , Bone Cements/adverse effects , Aged , Treatment Outcome , Aged, 80 and over , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Reoperation
12.
BMC Musculoskelet Disord ; 25(1): 350, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702748

ABSTRACT

BACKGROUND: Metacarpal shaft fracture is a common type of hand fracture. Numerous studies have explored fixing transverse fractures in the midshaft of the metacarpal bone. However, this section of the metacarpal bone is often susceptible to high-energy injury, resulting in comminuted fracture or bone loss. In such cases, wedge-shaped bone defects can develop in the metacarpal shaft, increasing the difficulty of performing fracture fixation. Notably, the research on this type of fracture fixation is limited. This study compared the abilities of four fixation methods to fix metacarpal shaft fractures with wedge-shaped bone defects. METHODS: In total, 28 artificial metacarpal bones were used. To create wedge-shaped bone defects, an electric saw was used to create metacarpal shaft fractures at the midshaft of each bone. The artificial metacarpal bones were then divided into four groups for fixation. The bones in the first group were fixed with a dorsal locked plate (DP group), those in the second group were fixed with a volar locked plate (VP group), and those in the third group were fixed by combining dorsal and volar locked plates (DP + VP group), and those in the fourth group were fixed with two K-wires (2 K group). Cantilever bending tests were conducted using a material testing machine to measure yielding force and stiffness. The four groups' fixation capabilities were then assessed through analysis of variance and Tukey's test. RESULTS: The DP + VP group (164.1±44.0 N) achieved a significantly higher yielding force relative to the 2 K group (50.7 ± 8.9 N); the DP group (13.6 ± 3.0 N) and VP group (12.3 ± 1.0 N) did not differ significantly in terms of yielding force, with both achieving lower yielding forces relative to the DP + VP group and 2 K group. The DP + VP group (19.8±6.3 N/mm) achieved the highest level of stiffness, and the other three groups did not differ significantly in terms of stiffness (2 K group, 5.4 ± 1.1 N/mm; DP group, 4.0 ± 0.9 N/mm; VP group, 3.9 ± 1.9 N/mm). CONCLUSIONS: The fixation method involving the combined use of dorsal and volar locked plates (DP + VP group) resulted in optimal outcomes with respect to fixing metacarpal shaft fractures with volar wedge bone defects.


Subject(s)
Bone Plates , Bone Wires , Fracture Fixation, Internal , Fractures, Bone , Metacarpal Bones , Metacarpal Bones/injuries , Metacarpal Bones/surgery , Humans , Biomechanical Phenomena , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fractures, Bone/surgery
13.
Georgian Med News ; (348): 40-43, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38807388

ABSTRACT

Complex comminuted hand injuries are an urgent medical and social problem of national health systems, which is especially sensitive for countries with a low level of socio-economic development. The work aims to substantiate the effectiveness and safety of the shoelace method of hand bone osteosynthesis in complex comminuted fractures (a clinical case study). Clinical case: A 42-year-old female patient was admitted to the clinic with complaints of the presence of a crushed wound on the 2nd finger of the left hand. The shoelace method was applied for hand bone osteosynthesis. The surgical intervention time was 24 minutes, and the time before returning to work or daily activities equaled 7.1 weeks. The time to bone fusion was less than 45 days. The shoelace osteosynthesis method in complex comminuted fractures of the hand bones has prospects for modern clinical practice with the possibility of improving the performance and safety indicators.


Subject(s)
Fracture Fixation, Internal , Fractures, Comminuted , Humans , Female , Adult , Fractures, Comminuted/surgery , Fractures, Comminuted/diagnostic imaging , Fracture Fixation, Internal/methods , Hand Injuries/surgery , Hand Bones/surgery , Hand Bones/injuries , Hand Bones/diagnostic imaging
14.
Article in English | MEDLINE | ID: mdl-38814258

ABSTRACT

Surgical ankle fractures pose a unique situation because both podiatrists and orthopaedic surgeons manage these injuries. Intraoperative fluoroscopy is routinely used; however, excessive radiation can be harmful to both the patient and the surgical team. The primary goal of this study was to determine whether there is a difference in the amount of intraoperative radiation exposure during ankle fracture open reduction and internal fixation (ORIF) when performed by orthopaedic surgeons versus podiatrists. This is a retrospective review of patients who underwent ankle fracture ORIF at an urban level I trauma center between January 1st, 2018, and April 1st, 2023. The electronic health record was queried using International Classification of Diseases nine and 10 codes associated with ankle fractures. Patients aged older than 18 years with an ankle fracture managed surgically were included. Subjects were then stratified by procedure. The mean total radiation dose (mRad) and mean total fluoroscopic time (seconds) were then compared between those performed by orthopaedic surgeons and podiatrists. Of the 333 included procedures, 186 were done by orthopaedic surgeons and 147 were done by podiatrists. Using multiple linear regression analysis to control for age, sex, race, ethnicity, and body mass index, patients undergoing isolated malleolus ORIF with syndesmosis repair performed by orthopaedic surgery were found to have a significantly lower mean fluoroscopic time compared with those performed by podiatry (68.4 s versus 104.8 s; P = 0.028). In addition, trimalleolar ORIF with syndesmotic repair performed by orthopaedic surgery had a significantly lower mean total radiation dose compared with those performed by podiatry (244.6 mRad v 565.6 mRad; P = 0.009). Patients and surgical teams are exposed to markedly less radiation in isolated malleolar and trimalleolar fracture ORIF with syndesmosis repair when performed by an orthopaedic surgeon as compared with those performed by a podiatrist.


Subject(s)
Ankle Fractures , Fracture Fixation, Internal , Open Fracture Reduction , Radiation Exposure , Humans , Fluoroscopy , Ankle Fractures/surgery , Ankle Fractures/diagnostic imaging , Retrospective Studies , Male , Female , Fracture Fixation, Internal/methods , Middle Aged , Adult , Podiatry , Aged , Radiation Dosage , Intraoperative Period , Orthopedics
15.
Jt Dis Relat Surg ; 35(2): 285-292, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38727106

ABSTRACT

OBJECTIVES: The study aimed to investigate the factors associated with shoulder stiffness following open reduction and internal fixation (ORIF) of proximal humeral fractures. PATIENTS AND METHODS: The retrospective study included a total of 151 patients who underwent ORIF of proximal humeral fractures between January 2016 and May 2021. Based on their shoulder joint motion at the latest follow-up, the patients were divided into two groups. The stiffness group (n=32; 8 males, 24 females; mean age: 62.4±9.3 years; range, 31 to 79 years), exhibited restricted shoulder forward flexion (<120°), limited arm lateral external rotation (<30°), and reduced back internal rotation below the L3 level. The remaining patients were included in the non-stiffness group (n=119; 52 males, 67 females; mean age: 56.4±13.4 years; range, 18 to 90 years). Various factors were examined to evaluate the association with shoulder stiffness following ORIF of proximal humeral fractures by multivariate unconditional logistic regression models. RESULTS: The mean follow-up duration was 31.8±12.6 (range, 12 to 68) months. Based on the results of the multivariate regression analysis, it was found that high-energy injuries [compared to low-energy injuries; adjusted odds ratio (aOR)=7.706, 95% confidence interval (CI): 3.564-15.579, p<0.001], a time from injury to surgery longer than one week (compared to a time from injury to surgery equal to or less than one week; aOR=5.275, 95% CI: 1.7321-9.472, p=0.031), and a body mass index (BMI) >24.0 kg/m2 (compared to a BMI between 18.5 and 24.0 kg/m2 ; aOR=4.427, 95% CI: 1.671-11.722, p=0.023) were identified as risk factors for shoulder stiffness following ORIF of proximal humeral fractures. CONCLUSION: High-energy injury, time from injury to surgery longer than one week, and BMI >24.0 kg/m2 were identified as independent risk factors for shoulder stiffness after proximal humeral fracture surgery, which should be treated with caution in clinical treatment.


Subject(s)
Fracture Fixation, Internal , Open Fracture Reduction , Range of Motion, Articular , Shoulder Fractures , Humans , Male , Middle Aged , Shoulder Fractures/surgery , Female , Aged , Retrospective Studies , Adult , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Open Fracture Reduction/methods , Open Fracture Reduction/adverse effects , Shoulder Joint/surgery , Shoulder Joint/physiopathology , Aged, 80 and over , Risk Factors , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Young Adult
16.
Jt Dis Relat Surg ; 35(2): 439-442, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38727126

ABSTRACT

Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.


Subject(s)
Bone Wires , Foreign-Body Migration , Olecranon Process , Osteotomy , Humans , Bone Wires/adverse effects , Male , Middle Aged , Olecranon Process/injuries , Olecranon Process/surgery , Olecranon Process/diagnostic imaging , Osteotomy/adverse effects , Osteotomy/methods , Osteotomy/instrumentation , Foreign-Body Migration/surgery , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Humeral Fractures/surgery , Humeral Fractures/diagnostic imaging , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Device Removal/methods , Elbow Joint/surgery , Elbow Joint/diagnostic imaging , Intra-Articular Fractures/surgery , Intra-Articular Fractures/diagnostic imaging
17.
BMC Musculoskelet Disord ; 25(1): 343, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38693479

ABSTRACT

PURPOSE: To explore whether it is necessary to put drain tubes after posterior pedicle screw fixation of thoracolumbar fractures. METHODS: From April 2020 to January 2023, a total of 291 patients with recent thoracolumbar fractures (AO type-A or type-B) who received the pedicle screw fixation operation were enrolled retrospectively. In 77 patients, drain tubes were used in the pedicle screw fixation surgery, while no drain tubes were placed in the other group. After gleaning demographic information and results of lab examination and imageology examination, all data were put into a database. Independent-sample t-tests, Pearson Chi-Square tests, Linear regression analysis, and correlation analysis were then performed. RESULTS: Compared to the control group, the drainage group had significantly lower postoperative CRP levels (P = 0.047), less use of antipyretics (P = 0.035), higher ADL scores (P = 0.001), and lower NRS scores (P < 0.001) on the 6th day after surgery. Other investigation items, such as demographic information, operation time, intraoperative blood loss, body temperature, and other preoperative and postoperative lab results, showed no significant differences. CONCLUSIONS: The use of a drain tube in the pedicle screw fixation of thoracolumbar fractures is correlated with the improvement of patients' living and activity ability and the reduction of inflammation, postoperative fever and pain.


Subject(s)
Drainage , Fracture Fixation, Internal , Lumbar Vertebrae , Pedicle Screws , Spinal Fractures , Thoracic Vertebrae , Humans , Male , Thoracic Vertebrae/surgery , Thoracic Vertebrae/injuries , Spinal Fractures/surgery , Spinal Fractures/diagnostic imaging , Lumbar Vertebrae/surgery , Lumbar Vertebrae/injuries , Female , Retrospective Studies , Adult , Middle Aged , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/adverse effects , Drainage/instrumentation , Drainage/methods , Treatment Outcome , Aged
18.
PLoS One ; 19(5): e0302839, 2024.
Article in English | MEDLINE | ID: mdl-38696506

ABSTRACT

PURPOSES: Fractures of the inferior patellar pole, unlike other patellar fractures, present challenges for traditional surgical fixation methods. This article introduces the clinical technique and outcomes of using Kirschner wire tension band combined with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures. METHODS: This retrospective case series study included 14 patients with comminuted inferior patellar pole fractures treated at our institution from September 1, 2020, to April 30, 2022. All patients underwent surgery using the Kirschner wire tension band with anchor screw cross-stitch technique. Follow-up assessments involved postoperative X-rays to evaluate fracture healing, as well as clinical parameters such as healing time, Visual Analog Scale (VAS) scores, range of motion (ROM), and Bostman scores. RESULTS: All patients were followed for an average of over 12 months, with no cases of internal fixation failure. Knee joint stability and function were excellent. X-rays revealed an average healing time of approximately 10.79 ± 1.53 weeks, hospitalization lasted 5.64 ± 1.15 days, surgery took approximately 37.86 ± 5.32 minutes, and intraoperative blood loss was 33.29 ± 8.15 ml. One patient experienced irritation from the internal fixation material. At the final follow-up, the Bostman score averaged 28.29 ± 0.83, knee joint flexion reached 131.07° ± 4.88°, all patients achieved full knee extension, and the VAS score was 0.36 ± 0.63. CONCLUSION: Kirschner wire tension band with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures delivered satisfactory clinical outcomes. This surgical method, characterized by its simplicity and reliability, is a valuable addition to clinical practice.


Subject(s)
Bone Wires , Fracture Fixation, Internal , Fractures, Comminuted , Patella , Humans , Male , Female , Adult , Patella/surgery , Patella/injuries , Fractures, Comminuted/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Retrospective Studies , Middle Aged , Range of Motion, Articular , Treatment Outcome , Fractures, Bone/surgery , Fracture Healing , Knee Joint/surgery , Knee Joint/physiopathology , Young Adult , Bone Screws , Suture Anchors
19.
Dan Med J ; 71(5)2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38704836

ABSTRACT

INTRODUCTION: Following surgical management of patella fractures, patients commonly report pain; difficulties with weight-bearing tasks such as walking, running and climbing stairs; and restrictions in quality of life. Recently, a locking plate system for surgical management of patella fractures has been introduced. To date, no studies have compared standard treatment with tension band wiring with locking plate fixation in a randomised study design. We aim to compare the one-year patient-reported Knee Injury and Osteoarthritis Outcome subscale scores (KOOS5-subscales) after standard care tension band fixation with locking plate fixation for patients with patella fractures. METHODS: This is a multicentre randomised and prospective clinical trial. A total of 122 patients will be included in the study, and the primary outcome will be the KOOS subscales at 12 months after surgery. CONCLUSIONS: Findings from the present study are expected to advance our understanding of outcome following surgical treatment of patella fractures. FUNDING: This study is funded, in part, by the Novo Nordisk Foundation, Denmark. CLINICALTRIALS: gov ID: NCT04891549.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Fractures, Bone , Patella , Humans , Patella/injuries , Patella/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Fractures, Bone/surgery , Prospective Studies , Female , Male , Treatment Outcome , Bone Wires , Adult , Randomized Controlled Trials as Topic , Middle Aged , Denmark , Quality of Life , Patella Fracture
20.
Eur Rev Med Pharmacol Sci ; 28(8): 3208-3215, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38708479

ABSTRACT

OBJECTIVE: We sought to explore the effectiveness of cannulated screw fixation for femoral neck fractures in middle-aged and elderly patients assisted by a three-dimensional printing navigation template. PATIENTS AND METHODS: A total of 98 middle-aged and elderly patients who underwent cannulated screw fixation for femoral neck fractures were retrospectively analyzed. They were allocated into two groups, each comprising 49 patients. Surgical indexes, hip function, and pain levels were compared between the two groups. RESULTS: The study group, assisted by the three-dimensional printing navigation template, exhibited significantly reduced nail insertion, fewer instances of C-arm fluoroscopy, shorter operation time, quicker time to bone union, earlier initiation of walking exercise, shorter time to weight-bearing walking, and reduced hospital stay than those in the control group (all p<0.001). However, the study group also experienced higher blood loss compared to the control group (p<0.001). Postoperatively, at 3 months and 12 months, the study group demonstrated significantly higher scores compared to the control group (both p<0.001) and reported significantly lower pain scores than that in the other group at 1 week and 12 months post-surgery (both p<0.001). Furthermore, the study group experienced significantly fewer postoperative complications than the control group (p=0.029). CONCLUSIONS: Cannulated screw fixation for femoral neck fractures assisted by a 3D printing navigation template is more effective and safer than traditional fixation methods. This approach represents a promising alternative for surgical management.


Subject(s)
Bone Screws , Femoral Neck Fractures , Fracture Fixation, Internal , Printing, Three-Dimensional , Humans , Femoral Neck Fractures/surgery , Middle Aged , Aged , Female , Male , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...