Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.226
Filter
1.
BMC Vet Res ; 20(1): 188, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730373

ABSTRACT

Femoral fractures are often considered lethal for adult horses because femur osteosynthesis is still a surgical challenge. For equine femur osteosynthesis, primary stability is essential, but the detailed physiological forces occurring in the hindlimb are largely unknown. The objective of this study was to create a numerical testing environment to evaluate equine femur osteosynthesis based on physiological conditions. The study was designed as a finite element analysis (FEA) of the femur using a musculoskeletal model of the loading situation in stance. Relevant forces were determined in the musculoskeletal model via optimization. The treatment of four different fracture types with an intramedullary nail was investigated in FEA with loading conditions derived from the model. The analyzed diaphyseal fracture types were a transverse (TR) fracture, two oblique fractures in different orientations (OB-ML: medial-lateral and OB-AP: anterior-posterior) and a "gap" fracture (GAP) without contact between the fragments. For the native femur, the most relevant areas of increased stress were located distally to the femoral head and proximally to the caudal side of the condyles. For all fracture types, the highest stresses in the implant material were present in the fracture-adjacent screws. Maximum compressive (-348 MPa) and tensile stress (197 MPa) were found for the GAP fracture, but material strength was not exceeded. The mathematical model was able to predict a load distribution in the femur of the standing horse and was used to assess the performance of internal fixation devices via FEA. The analyzed intramedullary nail and screws showed sufficient stability for all fracture types.


Subject(s)
Femoral Fractures , Fracture Fixation, Internal , Hindlimb , Animals , Horses/physiology , Biomechanical Phenomena , Femoral Fractures/veterinary , Femoral Fractures/surgery , Fracture Fixation, Internal/veterinary , Fracture Fixation, Internal/methods , Hindlimb/surgery , Finite Element Analysis , Femur/surgery , Models, Biological , Weight-Bearing , Fracture Fixation, Intramedullary/veterinary , Fracture Fixation, Intramedullary/instrumentation
2.
Eur Rev Med Pharmacol Sci ; 28(8): 3165-3175, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38708475

ABSTRACT

OBJECTIVE: Periprosthetic fractures following total knee replacement are rare but challenging. The goal of the treatment is to achieve the most stable fixation that allows early mobilization. Therefore, the aim of this study was to evaluate the biomechanical results of the use of different fixation systems in the treatment of distal femur periprosthetic fractures with finite element analysis. MATERIALS AND METHODS: A total knee prosthesis was implanted in Sawbone femur models. A transverse fracture line was created in the supracondylar region and was fixed in four different groups. In group 1, fracture line fixation was fixed using retrograde intramedullary nailing. In group 2, fixation was applied using a lateral anatomic distal femoral. In group 3, in addition to the fixation made in group 1, a lateral anatomic distal femoral plate was used. In group 4, in addition to the fixation made in group 2, a 3.5 mm Limited Contact Dynamic Compression Plate (LC-DCP) was applied medially. Computed Tomography (CT) scans were taken of the created models and were converted to three-dimensional models. Axial and rotational loading forces were applied to all the created models. RESULTS: The least deformation with axial loading was observed in the double plate group. Group 3 was determined to be more advantageous against rotational forces. The greatest movement in the fracture line was found in group 2. The application of the medial plate was determined to reduce the tension on the lateral plate and increase stability in the fracture line. CONCLUSIONS: Combining a lateral anatomic plate with intramedullary nailing or a medial plate was seen to be biomechanically more advantageous than using a lateral plate or intramedullary nailing alone in the treatment of distal femoral periprosthetic fractures.


Subject(s)
Arthroplasty, Replacement, Knee , Bone Nails , Bone Plates , Femoral Fractures , Finite Element Analysis , Fracture Fixation, Intramedullary , Periprosthetic Fractures , Arthroplasty, Replacement, Knee/adverse effects , Femoral Fractures/surgery , Humans , Periprosthetic Fractures/surgery , Fracture Fixation, Intramedullary/instrumentation , Bone Screws , Biomechanical Phenomena
3.
Medicina (Kaunas) ; 60(5)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38792901

ABSTRACT

Background and Objectives: This retrospective cohort study analyzes mechanical complications in hip fracture surgery using the Trochanteric Fixation Nail-Advanced (TFNA) implant. It investigates the correlation of these complications with demographic, intraoperative, and radiological factors, aiming to identify associated risk factors and suggest improvements in clinical surveillance and treatment strategies. Materials and Methods: We enrolled 253 patients diagnosed with pertrochanteric hip fractures treated between 2017 and 2021, with 126 meeting the criteria for a minimum 6-month follow-up. Data on demographics, American Anesthesia Association Classification (ASA), comorbidities, AO/OTA [AO (Arbeitsgemeinschaft für Osteosynthesefragen)/OTA (Orthopedic Trauma Association)] fracture classification, procedural details, and time to failure were collected. Radiographs were evaluated for reduction quality, the tip-apex distance (TAD), progressive varus deviation, and identification of mechanical complications. Statistical analysis was performed using SPSS software. Results: The predominant AO/OTA fracture classification was 31A2 in 67 cases (52.7%). Reduction quality was deemed good or acceptable in 123 cases (97.6%). The mean time to failure was 4.5 months (range: 2.2-6). The average TAD was 18 mm (range: 1.2-36), with a mean progressive varus deviation of 2.44° (range: 1.30-4.14). A good or acceptable reduction quality was observed in 97.6% of cases. Mechanical complications occurred in 21.4% of patients, with significant associations found with the lateral cortex fracture, use of a TFNA implant with a 130° angle, open reduction, and absence of prior osteoporosis treatment. Conclusions: The study provides insights into mechanical complications in proximal femur fractures treated with the TFNA nail, emphasizing the need for enhanced clinical and radiographic surveillance, especially in patients without osteoporosis treatment. Our findings support the necessity for further clinical studies comparing these outcomes with other implant designs and underscore the importance of personalized treatment strategies to reduce complication rates.


Subject(s)
Fracture Fixation, Intramedullary , Postoperative Complications , Humans , Retrospective Studies , Female , Male , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/adverse effects , Fracture Fixation, Intramedullary/instrumentation , Aged , Aged, 80 and over , Middle Aged , Postoperative Complications/etiology , Hip Fractures/surgery , Bone Nails , Cohort Studies , Femoral Fractures/surgery , Risk Factors , Proximal Femoral Fractures
4.
BMC Musculoskelet Disord ; 25(1): 405, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38783225

ABSTRACT

Femoral head varus is an important complication in intertrochanteric fracture patients treated with proximal femoral nail anti-rotation (PFNA) fixation. Theoretically, extending the length of the intramedullary nail could optimize fixation stability by lengthening the force arm. However, whether extending the nail length can optimize patient prognosis is unclear. In this study, a review of imaging data from intertrochanteric fracture patients with PFNA fixation was performed, and the length of the intramedullary nail in the femoral trunk and the distance between the lesser trochanter and the distal locking screw were measured. The femoral neck varus status was judged at the 6-month follow-up. The correlation coefficients between nail length and femoral neck varus angle were computed, and linear regression analysis was used to determine whether a change in nail length was an independent risk factor for femoral neck varus. Moreover, the biomechanical effects of different nail lengths on PFNA fixation stability and local stress distribution have also been verified by numerical mechanical simulations. Clinical review revealed that changes in nail length were not significantly correlated with femoral head varus and were also not an independent risk factor for this complication. In addition, only slight biomechanical changes can be observed in the numerical simulation results. Therefore, commonly used intramedullary nails should be able to meet the needs of PFNA-fixed patients, and additional procedures for longer nail insertion may be unnecessary.


Subject(s)
Bone Nails , Fracture Fixation, Intramedullary , Hip Fractures , Humans , Biomechanical Phenomena/physiology , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/adverse effects , Female , Male , Aged , Hip Fractures/surgery , Hip Fractures/diagnostic imaging , Femur Head/surgery , Femur Head/diagnostic imaging , Aged, 80 and over , Risk Factors , Middle Aged , Computer Simulation
5.
Jt Dis Relat Surg ; 35(2): 276-284, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38727105

ABSTRACT

OBJECTIVES: This study aimed to compare the efficacy and safety of the intramedullary nail and conventional plate for the treatment of displaced intra-articular calcaneal fractures from clinical comparative trials. MATERIALS AND METHODS: A comprehensive search of English databases was carried out in the Springer, PubMed, ScienceDirect, Web of Science, and Cochrane Library databases until September 2023. Studies on calcaneal fractures treated by an intramedullary nail or a plate were considered for inclusion. Endpoints included duration of operation, length of hospital stay, the Visual Analog Scale (VAS) score, postoperative functional score, radiological parameters, and complications. The mean difference (MD) and risk difference (RD) as the combined variables, as well as the 95% confidence intervals, (CIs) were calculated. RESULTS: Five retrospective controlled studies covering 473 feet at the one-year follow-up met the inclusion criteria. The meta-analysis demonstrated that there were significant differences in the duration of operation (MD: -10.81; 95% CI: -16.32, -5.31; p=0.0001), length of hospital stay (MD: -3.65; 95% CI: -4.35, -2.95; p<0.00001). No significant differences were found regarding postoperative American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale (MD: 0.36; 95% CI: -3.89, 4.61; p=0.87), VAS (MD: 1.95; 95% CI: -0.30, 4.21; p=0.09), or postoperative Böhler angle (MD: 0.94; 95% CI: -0.04, 1.92; p=0.06) between the two groups. The incidence of total complications (RD: -0.31; 95% CI: -0.46, -0.17; p<0.0001) and wound-healing complications (RD: -0.16; 95% CI: -0.30, -0.03; p=0.02) were lower in the intramedullary nail group. There were no significant differences in the incidences of revision surgery, implant removal, superficial wound infection, deep infection, and nonunion. CONCLUSION: Compared to conventional plates, the intramedullary nail showed a shorter duration of operation, reduced length of hospital stay, and fewer postoperative total complications and wound-healing complications in treating displaced intra-articular calcaneal fractures.


Subject(s)
Bone Nails , Bone Plates , Calcaneus , Fracture Fixation, Intramedullary , Humans , Calcaneus/injuries , Calcaneus/surgery , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/adverse effects , Intra-Articular Fractures/surgery , Length of Stay , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Treatment Outcome
6.
BMC Musculoskelet Disord ; 25(1): 389, 2024 May 18.
Article in English | MEDLINE | ID: mdl-38762453

ABSTRACT

BACKGROUND: Several methods have been used for the treatment of pediatric distal femoral fractures, such as elastic stable intramedullary nail (ESIN), external fixator (EF) and plate osteosynthesis, but there has been no consensus about the optimal method. The purpose of this study was to compare the clinical outcome between EF and ESIN techniques used in metaphyseal-diaphyseal junction (MDJ) fractures of the pediatric distal femur. METHODS: We retrospectively analyzed operatively treated MDJ fractures of pediatric distal femur between January 2015 and January 2022. Patient charts were reviewed for demographics, injury and data of radiography. All of the patients were divided into EF and ESIN groups according to the operation techniques. Malalignment was defined as more than 5 degrees of angular deformity in either plane. Clinical outcomes were measured by Flynn scoring system. RESULTS: Thirty-eight patients were included in this study, among which, 23 were treated with EF, and 15 with ESIN. The mean follow-up time was 18 months (12-24 months). At the final follow-up, all of the fractures were healed. Although there were no statistical differences between the two groups in demographic data, length of stay, estimated blood loss (EBL), rate of open reduction, time to fracture healing and Flynn score, the EF was superior to ESIN in operative time, fluoroscopic exposure and time to partial weight-bearing. The EF group had a significantly higher rate of skin irritation, while the ESIN had a significantly higher rate of malalignment. CONCLUSION: EF and ESIN are both effective methods in the treatment of MDJ fractures of the pediatric distal femur. ESIN is associated with lower rates of skin irritation. However, EF technique has the advantages of shorter operative time, reduced fluoroscopic exposure, and shorter time to partial weight-bearing, as well as lower incidence of malalignment. LEVEL OF EVIDENCE: Level III.


Subject(s)
Bone Nails , External Fixators , Femoral Fractures , Fracture Fixation, Intramedullary , Humans , Female , Male , Retrospective Studies , Femoral Fractures/surgery , Femoral Fractures/diagnostic imaging , Child , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Treatment Outcome , Case-Control Studies , Fracture Healing , Diaphyses/injuries , Diaphyses/surgery , Diaphyses/diagnostic imaging , Child, Preschool , Follow-Up Studies , Adolescent , Femur/surgery , Femur/diagnostic imaging
7.
J Orthop Traumatol ; 25(1): 23, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38653863

ABSTRACT

BACKGROUND: The exact positioning of the cephalomedullary (CM) nail entry point for managing femoral fractures remains debatable, with significant implications for fracture reduction and postoperative complications. This study aimed to explore the variability in the selection of the entry point among trauma surgeons, hypothesizing potential differences and their association with surgeon experience. METHODS: In this prospective multicenter study, 16 participants, ranging from residents to senior specialists, partook in a simulation wherein they determined the optimal entry point for the implantation of a proximal femoral nail antirotation (PFN-A; DePuy Synthes) in various femora. The inter- and intra-observer variability was calculated, along with comprehensive descriptive statistical analysis, to assess the variability in entry point selection and the impact of surgeon experience. RESULTS: In this study, the mean distance from the selected entry points to the calculated mean entry point was 3.98 mm, with a smaller distance observed among surgeons with more than 500 implantations (ANOVA, p = 0.050). Intra-surgeon variability for identical femora averaged at 5.14 mm, showing no significant differences across various levels of surgical experience or training. Notably, 13.6% of selected entry points would not allow a proper intramedullary positioning of the implant, thereby rendering anatomical repositioning unfeasible. Among these impossible entry points, a significant skew towards anterior placement was observed (70.6% of the impossible entry points), with a smaller fraction being overly lateral (27.5%) or medial (13.7%). On a patient level, the impossibility rate varied widely from 0 to 35% among the different femora examined, with a significantly higher rate seen in younger patients (mean age 55.02 versus 60.32; t-test for independent samples, p = 0.04). CONCLUSIONS: Significant variations exist in surgeons' selection of entry points for proximal femoral nailing, underscoring the task's complexity. Experience does not prevent the choice of unfeasible entry points, emphasizing the inadequacy of a universal approach and pointing towards the necessity for a patient-specific strategy for improved outcomes. TRIAL REGISTRATION NUMBER: DRKS00032465.


Subject(s)
Bone Nails , Femoral Fractures , Fracture Fixation, Intramedullary , Female , Humans , Male , Clinical Competence , Femoral Fractures/surgery , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Observer Variation , Prospective Studies
8.
Arch Orthop Trauma Surg ; 144(5): 2157-2163, 2024 May.
Article in English | MEDLINE | ID: mdl-38613611

ABSTRACT

INTRODUCTION: The standard surgical procedure for unstable ankle fractures is fixation of the lateral malleolus with a plate and screws. This method has a high risk of complications, especially among patients with fragile skin conditions. The aim of this study was to estimate the re-operation rates and identify complications in patients with an unstable ankle fracture, surgically treated with an intramedullary screw or rush pin. MATERIALS AND METHODS: We identified all patients who were surgically treated with either a 3.5-mm screw or rush pin at Aarhus University Hospital, Denmark, from 2012 to 2018. Major complications were re-operations within three months. We included 80 patients, of which 55 (69%) were treated with a 3.5-mm intramedullary screw and 25 (31%) with a rush pin. The majority of the study population was female (59) and the mean age was 75 (range 24 to 100) years. Of the 80 patients included, 41 patients had more than 2 comorbidities. RESULTS: Three patients underwent re-operation within three months due to either fracture displacement or hardware cutout. Radiographs obtained after six weeks showed that nine patients had loss of reduction. Additionally, four patients had superficial wound infections and six patients had delayed wound healing. CONCLUSIONS: Intramedullary fixation of distal fibula fractures with either a screw or rush pin has low re-operation rates. However, the high proportion of patients with radiological loss of reduction is concerning.


Subject(s)
Ankle Fractures , Bone Nails , Bone Screws , Fracture Fixation, Intramedullary , Reoperation , Humans , Female , Ankle Fractures/surgery , Male , Retrospective Studies , Middle Aged , Adult , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Aged , Aged, 80 and over , Reoperation/statistics & numerical data , Young Adult , Postoperative Complications/epidemiology
9.
Comput Biol Med ; 174: 108419, 2024 May.
Article in English | MEDLINE | ID: mdl-38583229

ABSTRACT

INTRODUCTION: In literature, there have been many studies conducted to research the alternatives of standard interlocking intramedullary nailing. The expandable wedge locked nail fixation, which is thought as a new alternative to the standard interlocking nailing, has been presented in previous numerical studies. The antegrade usage of the wedge locked nail fixation has provided promising results. From this point, the aim of the study is to evaluate mechanical behavior of its retrograde usage on femur models. Additionally, another aim of the study is to investigate the effect of fracture level on mechanical properties of the fixation. MATERIALS AND METHODS: The mechanical behaviors of the wedge locked nail and standard interlocking nail fixations were compared by finite element methods. Sawbones femurs having osteotomies at five different levels to simulate different fractures were fixed with wedge locked nail or interlocking nail by using retrograde approach. With respect to the fracture level, two different nail lengths were used. Axial compression load was applied to fixations. The mechanical behaviors of the fixations were evaluated with respect to stiffness of the fixations and stresses occurred on both implants and bones. RESULTS: Any of the wedge locked nail fixation did not slip at canal. The stress and stiffness results were mostly close with each other for both nail types. The maximum stresses at locking elements or bones contacting these elements increased with decreased distance between the fracture and relevant locking elements. DISCUSSION: The wedge locked nail fixation showed comparable results to the standard interlocking nail fixation with respect to the stiffness and stress. Under axial loading, wedge locked nail provided a secured fixation without any slippage and preserved its position inside the medullary canal. It may be thought as a safe alternative to the standard interlocking nail fixation for retrograde usage. Additionally, according to stress results, it is advised to the surgeons to avoid a close locking to the fracture line.


Subject(s)
Bone Nails , Finite Element Analysis , Fracture Fixation, Intramedullary , Humans , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Femoral Fractures/surgery , Femoral Fractures/physiopathology , Biomechanical Phenomena , Femur/surgery , Models, Biological
10.
Injury ; 55(6): 111516, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38604112

ABSTRACT

OBJECTIVES: The aim of this study was to compare the radiological and clinical results of femoral diaphyseal fractures operated in the lateral decubitus position with those operated in the supine position on a traction table and to detail the perioperative surgical technique. PATIENTS AND METHODS: Between October 2018 and January 2022, in this prospective, randomized, and single-blind comparative study, 75 patients diagnosed with adult femoral diaphyseal fractures to whom intramedullary nails were applied were operated in the lateral decubitus position without a traction table (Group 1, 37 patients) and in the supine position with a traction table (Group 2, 38 patients). Preoperative age, gender, fracture mechanism, fracture type, and surgical waiting times were determined. Perioperative anesthesia type, surgery preparation time, surgical time, number of fluoroscopy doses, amount of bleeding, and type of reduction were evaluated, and detailed observational descriptions of the surgical techniques were made. In the postoperative period, radiological evaluations were made with x-ray radiography and orthoroentgenogram, while in the clinical evaluation, hip-knee joint range of motion and rotational evaluation were made with the Craigs test. Follow-up periods were determined and complications noted. RESULTS: The average age was 32 in Group 1 and 28 in Group 2, the female/male ratio was 1:36 in Group 1 and 5:33 in Group 2, and the follow-up period was 18.2 months Group 1 and 21.7 months in Group 2. No significant difference was detected between the groups in terms of age, gender, fracture mechanism, fracture type, anesthesia type, surgical waiting time, and follow-up period (p > 0.05). Compared to Group 2, the shorter preparation time, surgical time, and number of fluoroscopy doses in Group 1 were found to be statistically significant (p < 0.05). The differences in the amount of bleeding and need for open reduction were not statistically significant between the groups (p > 0.05), and no statistical difference was found in joint range of motion and rotational evaluation in clinical evaluation in both groups (p > 0.05). There was no significant difference in terms of complications between groups. CONCLUSIONS: We found the lateral decubitus method without a traction table to be a safe and effective alternative to the supine method with a traction table in terms of the radiological and clinical results and that it also has the advantages of shortening the surgical time, reducing radiation exposure. LEVEL OF EVIDENCE: Level 1 prospective, randomized, single-blind controlled study.


Subject(s)
Femoral Fractures , Fracture Fixation, Intramedullary , Patient Positioning , Traction , Humans , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Female , Male , Femoral Fractures/surgery , Femoral Fractures/diagnostic imaging , Adult , Prospective Studies , Traction/methods , Patient Positioning/methods , Treatment Outcome , Single-Blind Method , Range of Motion, Articular , Middle Aged , Diaphyses/surgery , Diaphyses/injuries , Supine Position , Bone Nails , Operative Time , Young Adult , Radiography , Fracture Healing/physiology
11.
Injury ; 55(6): 111540, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38622039

ABSTRACT

OBJECTIVES: In far-distal extra-articular tibia fracture "extreme" nailing, debate surrounds the relative biomechanical performance of plating the fibula compared with extra distal interlocks. This study aimed to evaluate several constructs for extreme nailing including one interlock (one medial-lateral interlock), one interlock + plate (one medial-lateral interlock with lateral fibula compression plating), and two interlocks (one medial-lateral interlock and one anterior-posterior interlock). METHODS: Fifteen pairs of fresh cadaver legs were instrumented with a tibial nail to the physeal scar. A 1 cm segment of bone was resected from the distal tibia 3.5 cm from the joint and an oblique osteotomy was made in the distal fibula. We loaded specimens with three different distal fixation constructs (one interlock, one interlock + plate, and two interlocks) through 10,000 cycles form 100N-700 N of axial loading. Load to failure (Newtons), angulation and displacement were also measured. RESULTS: Mean load to failure was 2092 N (one interlock), 1917 N (one interlock + plate), and 2545 N (two interlocks). Linear mixed effects modeling demonstrated that two interlocks had a load to failure 578 N higher than one interlock alone (95 % CI, 74N-1082 N; P = 0.02), but demonstrated no significant difference between one interlock and one interlock + plate. No statistically significant difference in rates or timing of displacement >2 mm or angulation >10° were demonstrated. CONCLUSIONS: When nailing far-distal extra-articular tibia and fibula fractures, adding a second interlock provides more stability than adding a fibular plate. Distal fibula plating may have minimal biomechanical effect in extreme nailing.


Subject(s)
Bone Nails , Bone Plates , Cadaver , Fibula , Fracture Fixation, Intramedullary , Tibial Fractures , Humans , Tibial Fractures/surgery , Tibial Fractures/physiopathology , Biomechanical Phenomena , Fibula/surgery , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Male , Female , Weight-Bearing/physiology , Aged , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Aged, 80 and over
12.
Injury ; 55(6): 111533, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38631082

ABSTRACT

Diaphyseal fractures of the tibia is a common injury with an incidence of 16.9/100,000 population. Surgical treatment with intramedullary interlocking nail is the treatment of choice in closed diaphyseal tibial injuries. Removal of the nail is required in non-union, infected implant, implant failure or during exchange nailing procedure. Implant removal surgery presents some unique challenges to the Orthopaedic surgeons like broken nails, broken screws and failure of the extraction devices to engage with the threads of the nail due to stripping of the threads in the proximal part of the nail. Various techniques have been described by different authors to extract a broken distal piece of the nail. There are only a few articles described for the removal of an intramedullary nail when there is failure of the proximal extraction device. The failure of the proximal extraction device occurs due to the use of ill-fitting extraction bolts, cross threading and the presence of a very tight nail leading to stripping of the proximal threads. We describe a simple and novel technique with the use of the Stainless-Steel wire along with the extraction bolt when there is a failure of proximal extraction device for the extraction of cannulated or solid intramedullary nails.


Subject(s)
Bone Nails , Device Removal , Fracture Fixation, Intramedullary , Tibial Fractures , Humans , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Device Removal/methods , Tibial Fractures/surgery , Male , Treatment Outcome , Adult , Female , Equipment Failure , Middle Aged
13.
Injury ; 55(6): 111530, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38637188

ABSTRACT

Newer intramedullary (IM) nails have become another option in the fixation of proximal tibia fractures. There is limited data on the successful use of these implants in intra-articular and extra-articular fractures of the proximal tibia, and no studies assessing the ability of these implants to maintain alignment with early weight bearing. Our objective was to determine whether immediate weight bearing after IM fixation, with or without supplemental plate or screw fixation, of proximal third tibial fractures (OTA/AO 41A-C) results in a change in alignment prior to union. 35 patients with 39 proximal tibia fractures from 2015 to 2020, all treated with IM nailing with or without supplemental plate or screw fixation, all made weight-bearing as tolerated following surgery, were included. The main outcomes were change in medial proximal tibial angle (MPTA) and posterior proximal tibial angle (PPTA) from initial post-operative films to final follow up. 12 fractures were OTA/AO 41 type A, 14 were type B, and 13 were type C. Mean initial MPTA was 87.0 +/-2.53 degrees, while mean initial PPTA was 79.6 +/- 3.50 degrees. The mean change in MPTA was 0.048 +/- 2.8 degrees (P=0.92), and mean change in PPTA was 0.264 +/- 3.67 degrees. 92.3% of fractures had normal final coronal plane alignment, with MPTA between 85.0 and 90.0 degrees. 89.7% of fractures had normal final sagittal plane alignment, with PPTA between 77.0 and 84.0 degrees. No patients required reoperation for malalignment. In OTA/AO type 41 fractures, immediate weight bearing after IM nail fixation, with or without supplemental plate or screw fixation when indicated, leads to minimal change in final coronal or sagittal alignment, and was well tolerated in most patients. [authors blinded for review].


Subject(s)
Bone Nails , Bone Plates , Fracture Fixation, Intramedullary , Tibial Fractures , Weight-Bearing , Humans , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Weight-Bearing/physiology , Tibial Fractures/surgery , Tibial Fractures/physiopathology , Male , Female , Adult , Middle Aged , Treatment Outcome , Fracture Healing/physiology , Retrospective Studies , Bone Screws , Aged , Young Adult , Radiography
14.
Eur J Orthop Surg Traumatol ; 34(4): 1779-1794, 2024 May.
Article in English | MEDLINE | ID: mdl-38578441

ABSTRACT

PURPOSE: The patients with femoral metastasis in the inter- or subtrochanteric area could be treated with intramedullary nailing or prosthetic reconstruction, however, it is controversial which surgical treatment could offer less complications and implant failure. Our purpose was to define the risk of complications and implant survival in patients treated with intramedullary nailing or prosthetic reconstruction. METHODS: We analyzed studies reporting the risk of complications, reoperations and removal of the implant in patients treated with intramedullary nailing, hemiarthroplasty, arthroplasty or megaprosthesis. RESULTS: We analyzed 27 studies (1346 patients) reporting patients treated with intramedullary nail (51%), hemiarthroplasty (15%), arthroplasty (2%), megaprosthesis with (25%) or without (7%) acetabular component. No difference was found in the overall risk of complications between patients treated with intramedullary nailing 6%, hemiarthroplasty or total hip arthroplasty 7% and megaprosthesis 11% (p = 0.23). However, patients treated with megaprosthesis had increased risk of reoperation due to infection (70%), compared to the patients treated with intramedullary nail (13%), and patients treated with hemiarthroplasty or total hip arthroplasty (23%) (p = 0.02). Revision due to disease progression was required in 61% of the patients treated with intramedullary nail, but not in patients treated with hemiarthroplasty, total arthroplasty, and megaprosthesis (p = 0.03). CONCLUSION: Patients treated with megaprosthesis had higher risk of reoperation due to infection, while patients treated with intramedullary nailing had higher risk of revision due to disease progression. Regarding patients treated with megaprosthesis, the risk of reoperation due to dislocation was higher in those treated with acetabular component.


Subject(s)
Femoral Neoplasms , Fracture Fixation, Intramedullary , Postoperative Complications , Prosthesis Failure , Reoperation , Humans , Reoperation/statistics & numerical data , Fracture Fixation, Intramedullary/adverse effects , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Femoral Neoplasms/surgery , Femoral Neoplasms/secondary , Postoperative Complications/etiology , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Hemiarthroplasty/adverse effects , Hemiarthroplasty/methods
15.
Ortop Traumatol Rehabil ; 26(1): 369-373, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38646902

ABSTRACT

BACKGROUND: Pediatric femoral fractures are common in emergency rooms, with treatment options varying by age. This study compares elastic stable intramedullary nailing (ESIN) and plate fixation for diaphyseal femoral fractures in children aged 5-10. MATERIAL AND METHODS: Conducted at Al-Kindi Teaching Hospital, Baghdad, from December 2017 to December 2019, this prospective study included 32 children with closed transverse diaphyseal femoral fractures. Patients were divided into two groups: 16 treated with ESIN (Group 1) and 16 with plate fixation (Group 2). Criteria excluded comminuted, open, or pathological fractures. RESULTS: Group 1 had a mean age of 7.1 years and weight of 23.7 kg; Group 2 had a mean age of 7.8 years and weight of 30.9 kg. ESIN resulted in shorter operative times (58.4 minutes), earlier weight-bearing, and quicker fracture union (8.8 weeks) compared to plate fixation (76.3 minutes, 11.9 weeks). Blood loss was significantly less in Group 1 (32.8 ml) versus Group 2 (205.0 ml). No significant differences in wound healing or leg length discrepancies were observed. CONCLUSIONS: 1. Our study indicates a preference for Elastic Stable Intramedullary Nailing (ESIN) over plate fixation for pediatric femoral shaft fractures in children aged 5-10 years. 2. ESIN is associated with shorter operative times and faster commencement of weight-bearing, critical in pediatric recovery. 3. While ESIN is generally preferable, plate fixation may be better suited in certain clinical scenarios, emphasizing the importance of personalized treatment. 4. Based on our findings, ESIN is recommended for treating transverse diaphyseal femur fractures in the specified pediatric age group. 5. Recommends further studies, including randomized controlled trials, for a more comprehensive understanding of these treatments' long-term outcomes.


Subject(s)
Bone Plates , Femoral Fractures , Fracture Fixation, Intramedullary , Humans , Child , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Femoral Fractures/surgery , Prospective Studies , Female , Male , Child, Preschool , Treatment Outcome , Fracture Healing
16.
Ortop Traumatol Rehabil ; 26(1): 357-362, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38646900

ABSTRACT

BACKGROUND: Humerus shaft fractures are common in orthopaedic practice. The emphasis in treatment has shifted from prolonged immobilisation to early mobilisation and internal fixation when needed for a quicker return to normal function. Internal fixation methods include plate osteosynthesis and intramedullary nailing. This study specifically evaluated the effectiveness of flexible intramedullary nails in treating diaphyseal humeral fractures. MATERIAL AND METHODS: Between April 2007 and January 2010, Alexandria University Hospital treated 29 patients (21 males, 8 females) with diaphyseal humeral fractures. Treatment involved closed reduction and percutaneous fixation using two flexible nails. Patients, aged 17 to 65 with a mean age of 32, were included if they did not have pathological fractures, were above 16 years old, and were medically suitable. Causes included pedestrian vehicle accidents (17 cases) and falls or sports-related activities (12 cases). Surgical intervention occurred 1 to 8 days after the injury. RESULTS: Between April 2007 and January 2010, Alexandria University Hospital treated 29 patients (21 males, 8 females) for diaphyseal humeral fractures using closed reduction and percutaneous fixation with two flexible nails. Patients, aged 17 to 65, were monitored for an average of 18 months. Radiographic assessments showed complete union in nineteen fractures within 13 to 21 weeks. One patient experienced non-union but was successfully treated with bone grafting and plating. There were no significant intraoperative complications. Notably, four patients with preoperative radial nerve injuries recovered within 6 to 8 weeks. Evaluation using the Stewart and Hundley Scoring technique showed excellent outcomes for 60% of patients, good outcomes for 30%, fair outcomes for 5%, and poor outcomes for 5%. CONCLUSIONS: 1.The Elastic Stable Intramedullary Nailing (ESIN) technique shows promise in the treatment of humeral shaft fractures. 2. However, the success of treatment may depend on various factors, including patient age, fracture characteristics, and the presence of complications such as open fractures and radial nerve palsy. 3. Careful consideration of these factors is necessary when selecting a treatment approach for humeral shaft fractures.


Subject(s)
Bone Nails , Fracture Fixation, Intramedullary , Humeral Fractures , Humans , Male , Female , Adult , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Middle Aged , Humeral Fractures/surgery , Prospective Studies , Young Adult , Adolescent , Aged , Treatment Outcome , Diaphyses/surgery , Diaphyses/injuries , Fracture Healing , Egypt
17.
Acta Orthop Belg ; 90(1): 102-109, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38669658

ABSTRACT

In 2020, the most common treatment for presumed aseptic non-union of the humeral shaft seems to be decortication, often associated with bone autografting, and stabilized by a screw plate. We propose to evaluate an original technique of rigid osteosynthesis combining intramedullary nailing and screw plate. Between January 2004 and January 2020, 45 patients underwent treatment of presumed aseptic non-union of the humeral shaft by osteosynthesis combining intramedullary nailing and a screw plate. The minimum radio-clinical follow-up was one year postoperatively. The series included 19 men and 26 women with a mean age of 53 years (range 19-84 years). Bone consolidation was achieved in 43 patients, a rate of 95.5%. Comparing patients who achieved bone consolidation with the two failed consolidations did not reveal any statistically significant factor. Interobserver agreement was almost perfect (k=0.93) for the use of the RUST for humeral shaft fractures treated with intramedullary nailing and screw plate. In our study, the treatment of presumed aseptic non- union of the humeral shaft with an osteosynthesis combining intramedullary nailing and screw plate gives, with 95.5% of bone consolidation, results equal to or even superior to the different treatments currently described in the literature.


Subject(s)
Bone Plates , Bone Screws , Fracture Fixation, Intramedullary , Fractures, Ununited , Humeral Fractures , Humans , Middle Aged , Male , Adult , Female , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Aged , Humeral Fractures/surgery , Aged, 80 and over , Fractures, Ununited/surgery , Young Adult , Retrospective Studies , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Fracture Healing
18.
Zhongguo Gu Shang ; 37(4): 352-7, 2024 Apr 25.
Article in Chinese | MEDLINE | ID: mdl-38664204

ABSTRACT

OBJECTIVE: To compare the clinical outcomes of using elastic intramedullary nail and plate to fix fibular fracture. METHODS: The 60 patients with tibiofibular fractures admitted from January 2015 to December 2022 were divided into two groups:intramedullary nail group and plate group, 30 cases each, intramedullary nail group was treated with elastic intramedullary nail fixation group, plate group was treated with steel plate and screw fixation group. Intramedullary nail group, there were 18 males and 12 females, aged from 22 to 75 years old with an average of (39.4±9.8) years old, including 24 cases of traffic accidents injury, 6 cases of falling injury, 23 cases of closed fractures, 7 cases of open fractures. Steel plate group, there were 15 males and 15 females, aged from 24 to 78 years old with an average of (38.6±10.2) years old. The 22 cases were injured by traffic accident, 8 cases were injured by falling. The 24 cases were closed fractures and 6 cases were open fractures. The operation time, intraoperative bleeding, American Orthopedic Foot and Ankle Society (AOFAS) ankle and hind foot scores, clinical healing time of fibula and the incidence of wound complications were compared between the two groups. RESULTS: The patients in both groups were followed up for 6 to 21 months, with an average of (14.0±2.8) months. Compared with plate group, intramedullary nail group had shorter operative time, less bleeding, shorter clinical healing time of fibula, and lower infection rate of incision, and the difference was statistically significant (P<0.05). There were 2 cases of delayed healing in intramedullary nail group, 1 case of nonunion in plate group, and 2 cases of delayed healing in plate group, and there was no statistically significant difference between the two groups (P>0.05). In the last follow-up, according to the AOFAS scoring standard, the ankle function in intramedullary nail group was excellent in 17 cases, good in 12 cases, fair in 1 case, with an average of (88.33±4.57) points, while in plate group, excellent in 16 cases, good in 10 cases, fair in 4 cases, with an average of (87.00±4.14) points;There was no statistical difference between the two groups (P>0.05). CONCLUSION: Elastic intramedullary nail has the advantages of short operation time, less intraoperative bleeding, short fracture healing time and less incision complications in the treatment of fibular fracture, which is worthy of clinical application.


Subject(s)
Bone Nails , Bone Plates , Fibula , Tibial Fractures , Humans , Male , Female , Middle Aged , Adult , Aged , Fibula/injuries , Fibula/surgery , Tibial Fractures/surgery , Titanium , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Young Adult , Minimally Invasive Surgical Procedures/methods , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Steel
19.
Injury ; 55(6): 111512, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38537396

ABSTRACT

INTRODUCTION: This study aimed to compare the biomechanical properties of two types of intramedullary nails - reconstruction nails (RCN) and cephalomedullary nails (CMN) - each with different proximal fixations, in a model of an osteoporotic subtrochanteric femoral fracture. This study focused on assessing stiffness and load to failure of RCN and CMN nails to provide insight into their clinical applications in osteoporotic fracture treatments. MATERIALS AND METHODS: Ten synthetic osteoporotic femoral models were used to generate a comminuted subtrochanteric fracture model. Five femurs were fixed using an RCN, and the remaining five were fixed using a CMN. The constructs were subjected to axial compression to measure their structural stiffness, load to failure, and failure modes. RESULTS: The CMN group demonstrated a slightly higher load to failure (mean, 2250 N) than the RCN group (mean, 2100 N), which was statistically significant (p = 0.008). However, the stiffness in both groups was statistically similar (RCN, 250 N/mm; CMN, 255 N/mm; p = 0.69). Both groups showed a load to failure exceeding 1500 N, a typically exerted load on the femoral head by a 75 kg individual. The failure patterns differed, with CMN failures starting at the nail insertion area and RCN failures starting at the reconstruction screw area. CONCLUSION: The RCN offers stiffness comparable to that of the CMN; although its load to failure is slightly lower than that of the CMN, it still exceeds the physiological tolerance limit. These findings suggest that the RCN is a viable alternative for treating osteoporotic subtrochanteric fractures.


Subject(s)
Bone Nails , Fracture Fixation, Intramedullary , Hip Fractures , Osteoporotic Fractures , Humans , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Biomechanical Phenomena , Osteoporotic Fractures/surgery , Osteoporotic Fractures/physiopathology , Hip Fractures/surgery , Hip Fractures/physiopathology , Materials Testing , Fractures, Comminuted/surgery , Fractures, Comminuted/physiopathology , Weight-Bearing/physiology
20.
Eur J Orthop Surg Traumatol ; 34(4): 1893-1899, 2024 May.
Article in English | MEDLINE | ID: mdl-38451337

ABSTRACT

PURPOSE: Rotational malalignment and leg length discrepancy after intramedullary nailing of femoral shaft are frequent. This study has three objectives: evaluate the rate of femoral rotational malalignment and leg length discrepancy using EOS imaging after antegrade intramedullary nailing of femoral shaft fracture, find a relevant clinical examination to detect malrotation and identified risk factors. METHODS: We performed a retrospective single-centre study between January 2014 and January 2022. Fifty-eight patients were clinically and radiographically assessed at a minimum of three months. RESULTS: The femoral rotation of the operated side was significantly greater by a mean of 15.4° in internal rotation compared to the healthy side. There was no statically significant difference for the femoral length (p = 0.08). CONCLUSION: When using EOS stereography following antegrade intramedullary nailing of post-traumatic diaphyseal femur fractures, a statistically significant difference of more than 15.4° in internal rotation was found for femoral rotation on the operated side compared to the healthy side.Please confirm if the author names are presented accurately and in the correct sequence (given name, middle name/initial, family name). Author 1 Given name: [B. Poirot] Last name [Seynaeve]. Also, kindly confirm the details in the metadata are correct.The last name of the first author was corrected : Given name = B. and last name = Poirot Seynaeve The details in matadata are correct LEVEL OF EVIDENCE: III.


Subject(s)
Femoral Fractures , Fracture Fixation, Intramedullary , Humans , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/adverse effects , Fracture Fixation, Intramedullary/instrumentation , Femoral Fractures/surgery , Femoral Fractures/diagnostic imaging , Retrospective Studies , Male , Female , Adult , Middle Aged , Rotation , Leg Length Inequality/etiology , Leg Length Inequality/diagnostic imaging , Fractures, Malunited/diagnostic imaging , Fractures, Malunited/surgery , Imaging, Three-Dimensional/methods , Young Adult , Bone Malalignment/diagnostic imaging , Bone Malalignment/etiology , Aged , Femur/diagnostic imaging , Femur/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...