Results 1 - 20 de 1.642
Filter
1.
Clin Orthop Surg ; 16(3): 506-516, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38827756

ABSTRACT

Background: The gait analysis method that has been used in clinical practice to date is an optical tracking system (OTS) using a marker, but a markerless gait analysis (MGA) system is being developed because of the expensive cost and complicated examination of the OTS. To apply this MGA clinically, a comparative study of the MGA and OTS methods is necessary. The purpose of this study was to evaluate the compatibility between the OTS and the MGA methods and to evaluate the usefulness of the MGA system in actual clinical settings. Methods: From March 2021 to August 2021, 14 patients underwent gait analysis using the OTS and MGA system, and the spatiotemporal parameters and kinematic results obtained by the 2 methods were compared. To evaluate the practicality of the MGA system in an actual clinical setting, MGA was performed on 14 symptomatic children with idiopathic toe walking, who had been treated with a corrective cast, and the pre-cast and post-cast results were compared. For the OTS, the Motion Analysis Eagle system was used, and for MGA, DH Walk was used. Results: The spatiotemporal parameters showed no significant difference between the OTS and MGA system. The joint angle graphs of the kinematics along the sagittal plane showed similar shapes as a whole, with particularly high correlations in the hip and knee (pelvis: 29.4%, hip joint: 96.7%, knee joint: 94.9%, and ankle joint: 68.5%). A quantified comparison using the CORrelation and Analysis (CORA) score also showed high similarity between the 2 methods. The MGA results of pre-cast application and post-cast removal for children with idiopathic toe walking showed a statistically significant improvement in ankle dorsiflexion after treatment (p < 0.001). Conclusions: MGA showed a good correlation with the conventional OTS in terms of spatiotemporal parameters and kinematics. We demonstrated that ankle sagittal kinematics improved after treatment by corrective cast in children with idiopathic toe walking using the MGA method. Thus, after the improvement of a few limitations, the MGA system may soon be able to be clinically applied.


Subject(s)
Feasibility Studies , Gait Analysis , Humans , Gait Analysis/methods , Child , Male , Female , Biomechanical Phenomena , Adolescent , Gait/physiology , Child, Preschool
2.
Clin Orthop Surg ; 16(3): 455-460, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38827760

ABSTRACT

Background: Total ankle arthroplasty (TAA) enhances patients' subjective outcomes with respect to pain and function. The aim of this study was to analyze the biomechanical changes of the affected limb following TAA using gait analysis with a 3-dimensional multi-segment foot model (3D MFM). Methods: We reviewed medical records, simple radiographs, and gait analyses using a 3D MFM of patients who underwent TAA for severe varus ankle arthritis. Preoperative and postoperative gait data of 24 patients were compared. Postoperative gait analyses were done at least 1 year after surgery. Results: TAA significantly increased stride length (p = 0.024). The total range of motion of all planes in the hindfoot and forefoot showed no significant changes between preoperative and postoperative states. Hindfoot was significantly plantarflexed and pronated after TAA, while forefoot was significantly supinated in all phases. After appropriate calculations, the genuine coronal motion of the hindfoot showed no changes after TAA in all phases. Conclusions: TAA did not result in biomechanical improvements of segmental motions in the forefoot and hindfoot, except for changes to the bony structures. Therefore, it is important to point out to patients that TAA will not result in significant improvement of ankle function and range of motion. Clinicians can consider this information during preoperative counseling.


Subject(s)
Arthroplasty, Replacement, Ankle , Range of Motion, Articular , Humans , Male , Female , Middle Aged , Aged , Ankle Joint/surgery , Ankle Joint/physiopathology , Ankle Joint/diagnostic imaging , Biomechanical Phenomena , Gait Analysis , Imaging, Three-Dimensional , Retrospective Studies , Gait/physiology , Aged, 80 and over
3.
Sci Rep ; 14(1): 10828, 2024 05 11.
Article in English | MEDLINE | ID: mdl-38734731

ABSTRACT

Classifying gait patterns into homogeneous groups could enhance communication among healthcare providers, clinical decision making and clinical trial designs in boys with Duchenne muscular dystrophy (DMD). Sutherland's classification has been developed 40 years ago. Ever since, the state-of-the-art medical care has improved and boys with DMD are now longer ambulatory. Therefore, the gait classification requires an update. The overall aim was to develop an up-to-date, valid DMD gait classification. A total of 137 three-dimensional gait analysis sessions were collected in 30 boys with DMD, aged 4.6-17 years. Three classes were distinguished, which only partly aligned with increasing severity of gait deviations. Apart from the mildly affected pattern, two more severely affected gait patterns were found, namely the tiptoeing pattern and the flexion pattern with distinct anterior pelvic tilt and posterior trunk leaning, which showed most severe deviations at the ankle or at the proximal segments/joints, respectively. The agreement between Sutherland's and the current classification was low, suggesting that gait pathology with the current state-of-the-art medical care has changed. However, overlap between classes, especially between the two more affected classes, highlights the complexity of the continuous gait changes. Therefore, caution is required when classifying individual boys with DMD into classes.


Subject(s)
Gait , Muscular Dystrophy, Duchenne , Muscular Dystrophy, Duchenne/physiopathology , Humans , Child , Male , Gait/physiology , Child, Preschool , Adolescent , Gait Analysis/methods
4.
Gait Posture ; 111: 185-190, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38718524

ABSTRACT

BACKGROUND: The linear-envelope peak (LEP) of surface EMG signal is widely used in gait analysis to characterize muscular activity, especially in clinics. RESEARCH QUESTION: This study is designed to evaluate LEP accuracy in identifying muscular activation and assessing activation timing during walking. METHODS: Surface EMG signals from gastrocnemius lateralis (GL) and tibialis anterior (TA) were analyzed in 100 strides per subject (31 healthy subjects) during ground walking. Signals were full-wave rectified and low-pass filtered (cut-off frequency=5 Hz) to extract the linear envelope. LEP accuracy in identifying muscle activations and the associated error in peak detection were assessed by direct comparison with a reference method based on wavelet transform. LEP accuracy in identifying the timing of higher signalenergy levels was also assessed, increasing the reference-algorithm selectivity. RESULTS: The detection error (percentage number of times when LEP falls outside the correspondent reference activation interval) is close to zero. Detection error increases up to 70% for intervals including only signal energy higher than 90% of energy peak. Mean absolute error (MAE, the absolute value of the distance between LEP timing and the correspondent actual timing of the sEMG-signal peak computed by reference algorithm) is 54.1±20.0 ms. Detection error and MAE are significantly higher (p<0.05) in TA data compared to GL signals. Differences among MAE values detected adopting different values for LE cut-off frequency are not statistically significant. SIGNIFICANCE: LEP was found to be accurate in identifying the number of muscle activations during walking. However, the use of LEP to assess the timing of highest sEMG-signal energy (signal peak) should be considered carefully. Indeed, it could introduce a relevant inaccuracy in muscle-activation identification and peak-timing quantification. The type of muscle to analyze could also influence LEP performances, while the cut-off frequency chosen for envelope extraction appears to have a limited impact.


Subject(s)
Electromyography , Muscle, Skeletal , Walking , Humans , Muscle, Skeletal/physiology , Male , Walking/physiology , Adult , Female , Young Adult , Algorithms , Gait Analysis/methods
5.
Sci Rep ; 14(1): 10774, 2024 05 11.
Article in English | MEDLINE | ID: mdl-38729999

ABSTRACT

Muscular dystrophies (MD) are a group of genetic neuromuscular disorders that cause progressive weakness and loss of muscles over time, influencing 1 in 3500-5000 children worldwide. New and exciting treatment options have led to a critical need for a clinical post-marketing surveillance tool to confirm the efficacy and safety of these treatments after individuals receive them in a commercial setting. For MDs, functional gait assessment is a common approach to evaluate the efficacy of the treatments because muscle weakness is reflected in individuals' walking patterns. However, there is little incentive for the family to continue to travel for such assessments due to the lack of access to specialty centers. While various existing sensing devices, such as cameras, force plates, and wearables can assess gait at home, they are limited by privacy concerns, area of coverage, and discomfort in carrying devices, which is not practical for long-term, continuous monitoring in daily settings. In this study, we introduce a novel functional gait assessment system using ambient floor vibrations, which is non-invasive and scalable, requiring only low-cost and sparsely deployed geophone sensors attached to the floor surface, suitable for in-home usage. Our system captures floor vibrations generated by footsteps from patients while they walk around and analyzes such vibrations to extract essential gait health information. To enhance interpretability and reliability under various sensing scenarios, we translate the signal patterns of floor vibration to pathological gait patterns related to MD, and develop a hierarchical learning algorithm that aggregates insights from individual footsteps to estimate a person's overall gait performance. When evaluated through real-world experiments with 36 subjects (including 15 patients with MD), our floor vibration sensing system achieves a 94.8% accuracy in predicting functional gait stages for patients with MD. Our approach enables accurate, accessible, and scalable functional gait assessment, bringing MD progressive tracking into real life.


Subject(s)
Gait , Muscular Dystrophies , Vibration , Humans , Child , Gait/physiology , Muscular Dystrophies/physiopathology , Muscular Dystrophies/diagnosis , Muscular Dystrophies/therapy , Male , Female , Gait Analysis/methods , Gait Analysis/instrumentation , Adolescent
6.
Sensors (Basel) ; 24(9)2024 May 01.
Article in English | MEDLINE | ID: mdl-38732998

ABSTRACT

Biomechanical assessments of running typically take place inside motion capture laboratories. However, it is unclear whether data from these in-lab gait assessments are representative of gait during real-world running. This study sought to test how well real-world gait patterns are represented by in-lab gait data in two cohorts of runners equipped with consumer-grade wearable sensors measuring speed, step length, vertical oscillation, stance time, and leg stiffness. Cohort 1 (N = 49) completed an in-lab treadmill run plus five real-world runs of self-selected distances on self-selected courses. Cohort 2 (N = 19) completed a 2.4 km outdoor run on a known course plus five real-world runs of self-selected distances on self-selected courses. The degree to which in-lab gait reflected real-world gait was quantified using univariate overlap and multivariate depth overlap statistics, both for all real-world running and for real-world running on flat, straight segments only. When comparing in-lab and real-world data from the same subject, univariate overlap ranged from 65.7% (leg stiffness) to 95.2% (speed). When considering all gait metrics together, only 32.5% of real-world data were well-represented by in-lab data from the same subject. Pooling in-lab gait data across multiple subjects led to greater distributional overlap between in-lab and real-world data (depth overlap 89.3-90.3%) due to the broader variability in gait seen across (as opposed to within) subjects. Stratifying real-world running to only include flat, straight segments did not meaningfully increase the overlap between in-lab and real-world running (changes of <1%). Individual gait patterns during real-world running, as characterized by consumer-grade wearable sensors, are not well-represented by the same runner's in-lab data. Researchers and clinicians should consider "borrowing" information from a pool of many runners to predict individual gait behavior when using biomechanical data to make clinical or sports performance decisions.


Subject(s)
Gait , Running , Humans , Running/physiology , Gait/physiology , Male , Biomechanical Phenomena/physiology , Female , Adult , Wearable Electronic Devices , Young Adult , Gait Analysis/methods
7.
Sensors (Basel) ; 24(9)2024 May 06.
Article in English | MEDLINE | ID: mdl-38733050

ABSTRACT

Gait phase monitoring wearable sensors play a crucial role in assessing both health and athletic performance, offering valuable insights into an individual's gait pattern. In this study, we introduced a simple and cost-effective capacitive gait sensor manufacturing approach, utilizing a micropatterned polydimethylsiloxane dielectric layer placed between screen-printed silver electrodes. The sensor demonstrated inherent stretchability and durability, even when the electrode was bent at a 45-degree angle, it maintained an electrode resistance of approximately 3 Ω. This feature is particularly advantageous for gait monitoring applications. Furthermore, the fabricated flexible capacitive pressure sensor exhibited higher sensitivity and linearity at both low and high pressure and displayed very good stability. Notably, the sensors demonstrated rapid response and recovery times for both under low and high pressure. To further explore the capabilities of these new sensors, they were successfully tested as insole-type pressure sensors for real-time gait signal monitoring. The sensors displayed a well-balanced combination of sensitivity and response time, making them well-suited for gait analysis. Beyond gait analysis, the proposed sensor holds the potential for a wide range of applications within biomedical, sports, and commercial systems where soft and conformable sensors are preferred.


Subject(s)
Gait , Pressure , Wearable Electronic Devices , Wireless Technology , Humans , Gait/physiology , Wireless Technology/instrumentation , Gait Analysis/methods , Gait Analysis/instrumentation , Electrodes , Shoes , Equipment Design
8.
Sci Data ; 11(1): 556, 2024 May 30.
Article in English | MEDLINE | ID: mdl-38816523

ABSTRACT

Used on clinical and sportive context, three-dimensional motion analysis is considered as the gold standard in the biomechanics field. The proposed dataset has been established on 30 asymptomatic young participants. Volunteers were asked to walk at slow, comfortable and fast speeds, and to run at comfortable and fast speeds on overground and treadmill using shoes. Three dimensional trajectories of 63 reflective markers, 3D ground reaction forces and moments were simultaneously recorded. A total of 4840 and 18159 gait cycles were measured for overground and treadmill walking, respectively. Additionally, 2931 and 18945 cycles were measured for overground and treadmill running, respectively. The dataset is presented in C3D and CSV files either in raw or pre-processed format. The aim of this dataset is to provide a complete set of data that will help for the gait characterization during clinical gait analysis and in a sportive context. This data could be used for the creation of a baseline database for clinical purposes to research activities exploring the gait and the run.


Subject(s)
Gait , Running , Walking , Humans , Running/physiology , Young Adult , Biomechanical Phenomena , Healthy Volunteers , Adult , Gait Analysis , Male , Exercise Test
9.
Sci Rep ; 14(1): 11910, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38789587

ABSTRACT

The aim of this comparative, cross-sectional study was to determine whether markerless motion capture can track deviating gait patterns in children with cerebral palsy (CP) to a similar extent as marker-based motion capturing. Clinical gait analysis (CGA) was performed for 30 children with spastic CP and 15 typically developing (TD) children. Marker data were processed with the Human Body Model and video files with Theia3D markerless software, to calculate joint angles for both systems. Statistical parametric mapping paired t-tests were used to compare the trunk, pelvis, hip, knee and ankle joint angles, for both TD and CP, as well as for the deviation from the norm in the CP group. Individual differences were quantified using mean absolute differences. Markerless motion capture was able to track frontal plane angles and sagittal plane knee and ankle angles well, but individual deviations in pelvic tilt and transverse hip rotation as present in CP were not captured by the system. Markerless motion capture is a promising new method for CGA in children with CP, but requires improvement to better capture several clinically relevant deviations especially in pelvic tilt and transverse hip rotation.


Subject(s)
Cerebral Palsy , Gait Analysis , Humans , Cerebral Palsy/physiopathology , Child , Male , Female , Gait Analysis/methods , Cross-Sectional Studies , Gait/physiology , Knee Joint/physiopathology , Ankle Joint/physiopathology , Hip Joint/physiopathology , Biomechanical Phenomena , Adolescent , Range of Motion, Articular , Motion Capture
10.
J Biomech ; 169: 112112, 2024 May.
Article in English | MEDLINE | ID: mdl-38723413

ABSTRACT

The primary aim of this study was to assess whether measures of functional gait assessment were improved with robotic total knee arthroplasty (rTKA) when compared to manual TKA (mTKA). Gait analysis was performed as part of a randomised controlled trial. Walking and relaxed standing assessments were performed using an instrumented mat system. Spatiotemporal variables included gait cycle parameters, anteroposterior and lateral sway, and plantar pressure ratios. Measurements were recorded at pre-operative baseline and 12 months post-operatively. 100 patients were randomised, 50 to each group. Complete gait cycle data were available for 26 rTKA and 23 mTKA patients. Cadence and walking velocity showed overall improvements following surgery, with no difference between the two groups. In the operated limb, overall step and stride times decreased, while step and stride lengths increased. Subgroup analysis showed reduced propulsion time with rTKA, and decreased foot flat and mid stance times with mTKA. Lateral sway was decreased in the rTKA group. Plantar pressure ratios showed an overall increase in hindfoot loading on the operated limb, with no difference between the two groups. No other significant differences were identified between rTKA and mTKA at 12 months, and limitations may include statistical error. A small sample of the study cohort was followed up; analysis may represent the results of satisfied patients with well-functioning TKA. Further study could incorporate proprioceptive and 3D gait analysis techniques to analyse knee kinetics and kinematics with robotic surgery. Pressure mapping could further subdivide the plantar surfaces to explore any nuances in differential loading.


Subject(s)
Arthroplasty, Replacement, Knee , Gait Analysis , Gait , Robotic Surgical Procedures , Humans , Arthroplasty, Replacement, Knee/methods , Female , Male , Aged , Robotic Surgical Procedures/methods , Middle Aged , Gait/physiology , Gait Analysis/methods , Biomechanical Phenomena , Knee Joint/surgery , Knee Joint/physiopathology
11.
Gait Posture ; 111: 162-168, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38703445

ABSTRACT

BACKGROUND: People with plantar flexor weakness generate less ankle push-off work during walking, resulting in inefficient proximal joint compensations. To increase push-off work, spring-like ankle foot orthoses (AFOs) can be provided. However, whether and in which patients AFOs increase push-off work and reduce compensatory hip and knee work is unknown. METHODS: In 18 people with bilateral plantar flexor weakness, we performed a 3D gait analysis at comfortable walking speed with shoes-only and with AFOs of which the stiffness was optimized. To account for walking speed differences between conditions, we compared relative joint work of the hip, knee and ankle joint. The relationships between relative work generated with shoes-only and changes in joint work with AFO were tested with Pearson correlations. RESULTS: No differences in relative ankle, knee and hip work over the gait cycle were found between shoes-only and AFO (p>0.499). Percentage of total ankle work generated during pre-swing increased with the AFO (AFO: 85.3±9.1% vs Shoes: 72.4±27.1%, p=0.026). At the hip, the AFO reduced relative work in pre-swing (AFO: 31.9±7.4% vs Shoes: 34.1±10.4%, p=0.038) and increased in loading response (AFO: 18.0±11.0% vs Shoes: 11.9±9.8%, p=0.022). Ankle work with shoes-only was inversely correlated with an increase in ankle work with AFO (r=-0.839, p<0.001) and this increase correlated with reduction in hip work with AFO (r=-0.650, p=0.004). DISCUSSION: Although stiffness-optimized AFOs did not alter the work distribution across the ankle, knee and hip joint compared to shoes-only walking, relative more ankle work was generated during push-off, causing a shift in hip work from pre-swing to loading response. Furthermore, larger ankle push-off deficits when walking with shoes-only were related with an increase in ankle work with AFO and reduction in compensatory hip work, indicating that more severely affected individuals benefit more from the energy storing-and-releasing capacity of AFOs.


Subject(s)
Ankle Joint , Foot Orthoses , Humans , Male , Female , Ankle Joint/physiopathology , Middle Aged , Adult , Biomechanical Phenomena , Hip Joint/physiopathology , Gait Analysis , Knee Joint/physiopathology , Neuromuscular Diseases/rehabilitation , Neuromuscular Diseases/physiopathology , Gait/physiology , Shoes , Aged , Gait Disorders, Neurologic/rehabilitation , Gait Disorders, Neurologic/etiology , Gait Disorders, Neurologic/physiopathology
12.
ACS Nano ; 18(22): 14672-14684, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38760182

ABSTRACT

Flexible sensing systems (FSSs) designed to measure plantar pressure can deliver instantaneous feedback on human movement and posture. This feedback is crucial not only for preventing and controlling diseases associated with abnormal plantar pressures but also for optimizing athletes' postures to minimize injuries. The development of an optimal plantar pressure sensor hinges on key metrics such as a wide sensing range, high sensitivity, and long-term stability. However, the effectiveness of current flexible sensors is impeded by numerous challenges, including limitations in structural deformability, mechanical incompatibility between multifunctional layers, and instability under complex stress conditions. Addressing these limitations, we have engineered an integrated pressure sensing system with high sensitivity and reliability for human plantar pressure and gait analysis. It features a high-modulus, porous laminated ionic fiber structure with robust self-bonded interfaces, utilizing a unified polyimide material system. This system showcases a high sensitivity (156.6 kPa-1), an extensive sensing range (up to 4000 kPa), and augmented interfacial toughness and durability (over 150,000 cycles). Additionally, our FSS is capable of real-time monitoring of plantar pressure distribution across various sports activities. Leveraging deep learning, the flexible sensing system achieves a high-precision, intelligent recognition of different plantar types with a 99.8% accuracy rate. This approach provides a strategic advancement in the field of flexible pressure sensors, ensuring prolonged stability and accuracy even amidst complex pressure dynamics and providing a feasible solution for long-term gait monitoring and analysis.


Subject(s)
Pressure , Humans , Gait Analysis/instrumentation , Gait Analysis/methods , Wearable Electronic Devices , Gait/physiology , Foot/physiology
13.
Sensors (Basel) ; 24(10)2024 May 11.
Article in English | MEDLINE | ID: mdl-38793907

ABSTRACT

(1) Background: This study evaluates the effectiveness of low-frequency repetitive transcranial magnetic stimulation (LF-rTMS) in improving gait in post-stroke hemiplegic patients, using wearable sensor technology for objective gait analysis. (2) Methods: A total of 72 stroke patients were randomized into control, sham stimulation, and LF-rTMS groups, with all receiving standard medical treatment. The LF-rTMS group underwent stimulation on the unaffected hemisphere for 6 weeks. Key metrics including the Fugl-Meyer Assessment Lower Extremity (FMA-LE), Berg Balance Scale (BBS), Modified Barthel Index (MBI), and gait parameters were measured before and after treatment. (3) Results: The LF-rTMS group showed significant improvements in the FMA-LE, BBS, MBI, and various gait parameters compared to the control and sham groups (p < 0.05). Specifically, the FMA-LE scores improved by an average of 5 points (from 15 ± 3 to 20 ± 2), the BBS scores increased by 8 points (from 35 ± 5 to 43 ± 4), the MBI scores rose by 10 points (from 50 ± 8 to 60 ± 7), and notable enhancements in gait parameters were observed: the gait cycle time was reduced from 2.05 ± 0.51 s to 1.02 ± 0.11 s, the stride length increased from 0.56 ± 0.04 m to 0.97 ± 0.08 m, and the walking speed improved from 35.95 ± 7.14 cm/s to 75.03 ± 11.36 cm/s (all p < 0.001). No adverse events were reported. The control and sham groups exhibited improvements but were not as significant. (4) Conclusions: LF-rTMS on the unaffected hemisphere significantly enhances lower-limb function, balance, and daily living activities in subacute stroke patients, with the gait parameters showing a notable improvement. Wearable sensor technology proves effective in providing detailed, objective gait analysis, offering valuable insights for clinical applications in stroke rehabilitation.


Subject(s)
Gait , Stroke Rehabilitation , Stroke , Transcranial Magnetic Stimulation , Wearable Electronic Devices , Humans , Male , Female , Transcranial Magnetic Stimulation/methods , Transcranial Magnetic Stimulation/instrumentation , Middle Aged , Stroke/physiopathology , Stroke/therapy , Gait/physiology , Aged , Stroke Rehabilitation/instrumentation , Stroke Rehabilitation/methods , Gait Analysis/methods
14.
Sensors (Basel) ; 24(10)2024 May 13.
Article in English | MEDLINE | ID: mdl-38793945

ABSTRACT

The progress in markerless technologies is providing clinicians with tools to shorten the time of assessment rapidly, but raises questions about the potential trade-off in accuracy compared to traditional marker-based systems. This study evaluated the OpenCap system against a traditional marker-based system-Vicon. Our focus was on its performance in capturing walking both toward and away from two iPhone cameras in the same setting, which allowed capturing the Timed Up and Go (TUG) test. The performance of the OpenCap system was compared to that of a standard marker-based system by comparing spatial-temporal and kinematic parameters in 10 participants. The study focused on identifying potential discrepancies in accuracy and comparing results using correlation analysis. Case examples further explored our results. The OpenCap system demonstrated good accuracy in spatial-temporal parameters but faced challenges in accurately capturing kinematic parameters, especially in the walking direction facing away from the cameras. Notably, the two walking directions observed significant differences in pelvic obliquity, hip abduction, and ankle flexion. Our findings suggest areas for improvement in markerless technologies, highlighting their potential in clinical settings.


Subject(s)
Gait Analysis , Gait , Smartphone , Walking , Humans , Pilot Projects , Gait Analysis/methods , Gait Analysis/instrumentation , Male , Biomechanical Phenomena/physiology , Female , Gait/physiology , Walking/physiology , Adult
15.
Acta Orthop Belg ; 90(1): 147-153, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38669666

ABSTRACT

In this article we report a case of a 53-year-old patient diagnosed with end-stage osteoarthritis (OA) of the knee. The patient underwent treatment with knee joint distraction (KJD) with the aim to postpone total knee arthroplasty and prevent potential revision surgery. To assess the effect of KJD, a 3D gait analysis was performed preoperative and one year postoperative. In this patient, preoperative 3D gait analysis revealed an increased knee adduction moment (KAM) compared to healthy levels. Postoperative the KAM decreased, approaching healthy levels, suggesting potential improvements in disease status or in gait. Consequently, further investigation into the effectiveness of Knee Joint Distraction (KJD) as a treatment option for relatively young patients with knee OA is warranted. Gait analysis has emerged as an effective tool for assessing treatment outcomes of innovative treatment such as KJD at the individual level.


Subject(s)
Knee Joint , Osteoarthritis, Knee , Humans , Osteoarthritis, Knee/surgery , Middle Aged , Knee Joint/surgery , Knee Joint/physiopathology , Range of Motion, Articular , Male , Gait/physiology , Arthroplasty, Replacement, Knee/methods , Gait Analysis , Female
16.
Pediatr Phys Ther ; 36(2): 182-206, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38568266

ABSTRACT

BACKGROUND: Children with cerebral palsy (CP) who walk have complex gait patterns and deviations often requiring physical therapy (PT)/medical/surgical interventions. Walking in children with CP can be assessed with 3-dimensional instrumented gait analysis (3D-IGA) providing kinematics (joint angles), kinetics (joint moments/powers), and muscle activity. PURPOSE: This clinical practice guideline provides PTs, physicians, and associated clinicians involved in the care of children with CP, with 7 action statements on when and how 3D-IGA can inform clinical assessments and potential interventions. It links the action statement grades with specific levels of evidence based on a critical appraisal of the literature. CONCLUSIONS: This clinical practice guideline addresses 3D-IGA's utility to inform surgical and non-surgical interventions, to identify gait deviations among segments/joints and planes and to evaluate the effectiveness of interventions. Best practice statements provide guidance for clinicians about the preferred characteristics of 3D-IGA laboratories including instrumentation, staffing, and reporting practices.Video Abstract: Supplemental digital content available at http://links.lww.com/PPT/A524.


Subject(s)
Cerebral Palsy , Gait Analysis , Child , Humans , Evidence-Based Practice , Gait , Immunoglobulin A
17.
PLoS One ; 19(4): e0300447, 2024.
Article in English | MEDLINE | ID: mdl-38564508

ABSTRACT

Quantitative gait analysis is important for understanding the non-typical walking patterns associated with mobility impairments. Conventional linear statistical methods and machine learning (ML) models are commonly used to assess gait performance and related changes in the gait parameters. Nonetheless, explainable machine learning provides an alternative technique for distinguishing the significant and influential gait changes stemming from a given intervention. The goal of this work was to demonstrate the use of explainable ML models in gait analysis for prosthetic rehabilitation in both population- and sample-based interpretability analyses. Models were developed to classify amputee gait with two types of prosthetic knee joints. Sagittal plane gait patterns of 21 individuals with unilateral transfemoral amputations were video-recorded and 19 spatiotemporal and kinematic gait parameters were extracted and included in the models. Four ML models-logistic regression, support vector machine, random forest, and LightGBM-were assessed and tested for accuracy and precision. The Shapley Additive exPlanations (SHAP) framework was applied to examine global and local interpretability. Random Forest yielded the highest classification accuracy (98.3%). The SHAP framework quantified the level of influence of each gait parameter in the models where knee flexion-related parameters were found the most influential factors in yielding the outcomes of the models. The sample-based explainable ML provided additional insights over the population-based analyses, including an understanding of the effect of the knee type on the walking style of a specific sample, and whether or not it agreed with global interpretations. It was concluded that explainable ML models can be powerful tools for the assessment of gait-related clinical interventions, revealing important parameters that may be overlooked using conventional statistical methods.


Subject(s)
Artificial Limbs , Gait Analysis , Humans , Gait , Walking , Knee
18.
BMC Musculoskelet Disord ; 25(1): 335, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38671405

ABSTRACT

BACKGROUND: This study analysed changes in gait and pedobarography and subjective and functional outcomes after isolated Chopart joint injury. METHODS: The results of 14 patients were reviewed. Kinematic 3D gait analysis, comparative bilateral electromyography (EMG) and pedobarography were performed. RESULTS: On the injured side, the 3D gait analysis showed a significantly increased internal rotation and decreased external rotation of the hip and significantly decreased adduction and decreased range of motion (ROM) for the ankle. On the healthy side, the pedobarography revealed a significantly increased mean force in the forefoot, an increased peak maximum force and an increased maximum pressure in the metatarsal. When standing, significantly more weight was placed on the healthy side. The EMG measurements showed no significant differences between the healthy and injured legs. CONCLUSIONS: After isolated Chopart injuries, significant changes in gait and pedobarography can be seen over the long term.


Subject(s)
Gait , Humans , Male , Adult , Biomechanical Phenomena , Female , Gait/physiology , Middle Aged , Young Adult , Electromyography , Range of Motion, Articular , Ankle Injuries/physiopathology , Gait Analysis/methods , Ankle Joint/physiopathology
19.
Sensors (Basel) ; 24(8)2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38676029

ABSTRACT

The increasing use of inertial measurement units (IMU) in biomedical sciences brings new possibilities for clinical research. The aim of this paper is to demonstrate the accuracy of the IMU-based wearable Syde® device, which allows day-long and remote continuous gait recording in comparison to a reference motion capture system. Twelve healthy subjects (age: 23.17 ± 2.04, height: 174.17 ± 6.46 cm) participated in a controlled environment data collection and performed a series of gait tasks with both systems attached to each ankle. A total of 2820 strides were analyzed. The results show a median absolute stride length error of 1.86 cm between the IMU-based wearable device reconstruction and the motion capture ground truth, with the 75th percentile at 3.24 cm. The median absolute stride horizontal velocity error was 1.56 cm/s, with the 75th percentile at 2.63 cm/s. With a measurement error to the reference system of less than 3 cm, we conclude that there is a valid physical recovery of stride length and horizontal velocity from data collected with the IMU-based wearable Syde® device.


Subject(s)
Ankle , Gait , Wearable Electronic Devices , Humans , Gait/physiology , Male , Ankle/physiology , Female , Adult , Young Adult , Biomechanical Phenomena/physiology , Accelerometry/instrumentation , Accelerometry/methods , Gait Analysis/methods , Gait Analysis/instrumentation
20.
Sensors (Basel) ; 24(8)2024 Apr 13.
Article in English | MEDLINE | ID: mdl-38676114

ABSTRACT

Quantitative analysis of human gait is critical for the early discovery, progressive tracking, and rehabilitation of neurological and musculoskeletal disorders, such as Parkinson's disease, stroke, and cerebral palsy. Gait analysis typically involves estimating gait characteristics, such as spatiotemporal gait parameters and gait health indicators (e.g., step time, length, symmetry, and balance). Traditional methods of gait analysis involve the use of cameras, wearables, and force plates but are limited in operational requirements when applied in daily life, such as direct line-of-sight, carrying devices, and dense deployment. This paper introduces a novel approach for gait analysis by passively sensing floor vibrations generated by human footsteps using vibration sensors mounted on the floor surface. Our approach is low-cost, non-intrusive, and perceived as privacy-friendly, making it suitable for continuous gait health monitoring in daily life. Our algorithm estimates various gait parameters that are used as standard metrics in medical practices, including temporal parameters (step time, stride time, stance time, swing time, double-support time, and single-support time), spatial parameters (step length, width, angle, and stride length), and extracts gait health indicators (cadence/walking speed, left-right symmetry, gait balance, and initial contact types). The main challenge we addressed in this paper is the effect of different floor types on the resultant vibrations. We develop floor-adaptive algorithms to extract features that are generalizable to various practical settings, including homes, hospitals, and eldercare facilities. We evaluate our approach through real-world walking experiments with 20 adults with 12,231 labeled gait cycles across concrete and wooden floors. Our results show 90.5% (RMSE 0.08s), 71.3% (RMSE 0.38m), and 92.3% (RMSPE 7.7%) accuracy in estimating temporal, spatial parameters, and gait health indicators, respectively.


Subject(s)
Gait Analysis , Gait , Vibration , Humans , Gait/physiology , Gait Analysis/methods , Male , Algorithms , Female , Adult , Walking/physiology , Floors and Floorcoverings , Wearable Electronic Devices , Biomechanical Phenomena/physiology