Turk Kardiyol Dern Ars ; 52(4): 237-243, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38829634

ABSTRACT

OBJECTIVE: This study aims to explore the impact of sodium-glucose cotransporter-2 (SGLT-2) inhibitors, a newer class of oral antidiabetic drugs, on atrial electromechanical delay (EMD) in patients with type 2 diabetes mellitus (DM). This is particularly relevant given the significantly higher incidence of atrial fibrillation (AF) in diabetic patients compared to the general population. Atrial electromechanical delay is recognized as an important factor influencing the development of atrial fibrillation. METHODS: This study included 30 type 2 DM patients (53.3% female, mean age 60.07 ± 10.03 years), initiating treatment with SGLT-2 inhibitors. The patients were assessed using echocardiography at baseline and again at 6 months, focusing on basic echocardiographic parameters and atrial electromechanical delay times (EMD) measured via tissue Doppler imaging. RESULTS: No significant changes were observed in intra-atrial EMD times. However, significant reductions were noted in interatrial EMD times, decreasing from 15.13 ± 5.87 ms to 13.20 ± 6.12 ms (P = 0.029). Statistically significant shortening occurred in lateral pulmonary acceleration (PA) times (from 58.73 ± 6.41 ms to 54.37 ± 6.97 ms, P < 0.001), septal PA times (from 50.90 ± 6.02 ms to 48.23 ± 5), and tricuspid PA times (from 43.60 ± 6.28 ms to 41.30 ± 5.60 ms, P = 0.003). Additionally, there was a significant reduction in the E/e' ratio from 8.13 ± 4.0 to 6.50 ± 2.37 (P = 0.003). CONCLUSION: SGLT-2 inhibitors might positively influence atrial electromechanical conduction, reducing DM-related functional impairments and the risk of arrhythmias, particularly AF.


Subject(s)
Atrial Fibrillation , Diabetes Mellitus, Type 2 , Sodium-Glucose Transporter 2 Inhibitors , Humans , Female , Sodium-Glucose Transporter 2 Inhibitors/therapeutic use , Sodium-Glucose Transporter 2 Inhibitors/pharmacology , Diabetes Mellitus, Type 2/drug therapy , Diabetes Mellitus, Type 2/complications , Middle Aged , Male , Atrial Fibrillation/drug therapy , Atrial Fibrillation/physiopathology , Heart Atria/diagnostic imaging , Heart Atria/drug effects , Heart Atria/physiopathology , Aged , Heart Conduction System/drug effects , Heart Conduction System/physiopathology , Echocardiography
4.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38691562

ABSTRACT

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Septum , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Ventricular Septum/diagnostic imaging , Aged, 80 and over , Risk Factors , Aged , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnostic imaging , Heart Conduction System/physiopathology , Heart Conduction System/diagnostic imaging , Treatment Outcome , Predictive Value of Tests , Risk Assessment , Severity of Illness Index , Retrospective Studies , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Multidetector Computed Tomography , Tomography, X-Ray Computed , Action Potentials
5.
Arch Cardiovasc Dis ; 117(5): 304-312, 2024 May.
Article in English | MEDLINE | ID: mdl-38704289

ABSTRACT

BACKGROUND: Aortic valve infective endocarditis may be complicated by high-degree atrioventricular block in up to 10-20% of cases. AIM: To assess high-degree atrioventricular block occurrence, contributing factors, prognosis and evolution in patients referred for aortic infective endocarditis. METHODS: Two hundred and five patients referred for aortic valve infective endocarditis between January 2018 and March 2021 were included in this study. A comprehensive assessment of clinical, electrocardiographic, biological, microbiological and imaging data was conducted, with a follow-up carried out over 1 year. RESULTS: High-degree atrioventricular block occurred in 22 (11%) patients. In univariate analysis, high-degree atrioventricular block was associated with first-degree heart block at admission (odds ratio 3.1; P=0.015), periannular complication on echocardiography (odds ratio 6.9; P<0.001) and severe biological inflammatory syndrome, notably C-reactive protein (127 vs 90mg/L; P=0.011). In-hospital mortality (12.7%) was higher in patients with high-degree atrioventricular block (odds ratio 4.0; P=0.011) in univariate analysis. Of the 16 patients implanted with a permanent pacemaker for high-degree atrioventricular block and interrogated, only four (25%) were dependent on the pacing function at 1-year follow-up. CONCLUSIONS: High-degree atrioventricular block is associated with high inflammation markers and periannular complications, especially if first-degree heart block is identified at admission. High-degree atrioventricular block is a marker of infectious severity, and tends to raise the in-hospital mortality rate. Systematic assessment of patients admitted for infective endocarditis suspicion, considering these contributing factors, could indicate intensive care unit monitoring or even temporary pacemaker implantation in those at highest risk.


Subject(s)
Aortic Valve , Atrioventricular Block , Hospital Mortality , Pacemaker, Artificial , Humans , Male , Female , Atrioventricular Block/physiopathology , Atrioventricular Block/diagnosis , Atrioventricular Block/etiology , Atrioventricular Block/therapy , Atrioventricular Block/mortality , Middle Aged , Aged , Risk Factors , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/microbiology , Time Factors , Endocarditis/mortality , Endocarditis/diagnosis , Endocarditis/complications , Cardiac Pacing, Artificial , Retrospective Studies , Adult , Risk Assessment , Electrocardiography , Heart Rate , Aged, 80 and over , Heart Conduction System/physiopathology
6.
Arch Cardiovasc Dis ; 117(5): 313-320, 2024 May.
Article in English | MEDLINE | ID: mdl-38704288

ABSTRACT

BACKGROUND: In patients with congenital long QT syndrome (LQTS), the risk of ventricular arrhythmia is correlated with the duration of the corrected QT interval and the changes in the ST-T wave pattern on the 12-lead surface electrocardiogram (12L-ECG). Remote monitoring of these variables could be useful. AIM: To evaluate the abilities of two wearable electrocardiogram devices (Apple Watch and KardiaMobile 6L) to provide reliable electrocardiograms in terms of corrected QT interval and ST-T wave patterns in patients with LQTS. METHODS: In a prospective multicentre study (ClinicalTrials.gov identifier: NCT04728100), a 12L-ECG, a 6-lead KardiaMobile 6L electrocardiogram and two single-lead Apple Watch electrocardiograms were recorded in patients with LQTS. The corrected QT interval and ST-T wave patterns were evaluated manually. RESULTS: Overall, 98 patients with LQTS were included; 12.2% were children and 92.8% had a pathogenic variant in an LQTS gene. The main genotypes were LQTS type 1 (40.8%), LQTS type 2 (36.7%) and LQTS type 3 (7.1%); rarer genotypes were also represented. When comparing the ST-T wave patterns obtained with the 12L-ECG, the level of agreement was moderate with the Apple Watch (k=0.593) and substantial with the KardiaMobile 6L (k=0.651). Regarding the corrected QT interval, the correlation with 12L-ECG was strong for the Apple Watch (r=0.703 in lead II) and moderate for the KardiaMobile 6L (r=0.593). There was a slight overestimation of corrected QT interval with the Apple Watch and a subtle underestimation with the KardiaMobile 6L. CONCLUSIONS: In patients with LQTS, the corrected QT interval and ST-T wave patterns obtained with the Apple Watch and the KardiaMobile 6L correlated with the 12L-ECG. Although wearable electrocardiogram devices cannot replace the 12L-ECG for the follow-up of these patients, they could be interesting additional monitoring tools.


Subject(s)
Heart Rate , Long QT Syndrome , Predictive Value of Tests , Wearable Electronic Devices , Humans , Long QT Syndrome/physiopathology , Long QT Syndrome/diagnosis , Long QT Syndrome/congenital , Long QT Syndrome/genetics , Female , Male , Prospective Studies , Child , Adolescent , Adult , Reproducibility of Results , Young Adult , Electrocardiography, Ambulatory/instrumentation , Action Potentials , Child, Preschool , Equipment Design , Time Factors , Middle Aged , Electrocardiography/instrumentation , Heart Conduction System/physiopathology
7.
Card Electrophysiol Clin ; 16(2): 163-168, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749636

ABSTRACT

A 69-year-old woman with a history of heart failure with reduced ejection fraction presented for device interrogation of her cardiac implantable electronic device (CIED), revealing lead and pulse generator displacement. Surprisingly, she exhibited a narrow QRS on the ECG despite an underlying right bundle branch block, suggesting unintentional conduction system pacing (CSP). Traditional cardiac resynchronization therapy has been widely used for patients with heart failure, but alternatives like CSP are emerging as viable options. Given the global rise in CIED utilization, regular follow-up, device troubleshooting, and embracing remote monitoring are essential to manage and optimize patient outcomes.


Subject(s)
Cardiac Resynchronization Therapy Devices , Cardiac Resynchronization Therapy , Heart Failure , Aged , Female , Humans , Bundle-Branch Block/therapy , Bundle-Branch Block/physiopathology , Electrocardiography , Equipment Failure , Heart Conduction System/physiopathology , Heart Failure/therapy , Heart Failure/physiopathology
8.
G Ital Cardiol (Rome) ; 25(5): 327-339, 2024 05.
Article in Italian | MEDLINE | ID: mdl-38639123

ABSTRACT

For many years, cardiac pacing has been based on the stimulation of right ventricular common myocardium to correct diseases of the conduction system. The birth and the development of cardiac resynchronization have led to growing interest in the correction and prevention of pacing-induced dyssynchrony. Many observational studies and some randomized clinical trials have shown that conduction system pacing (CSP) can not only prevent pacing-induced dyssynchrony but can also correct proximal conduction system blocks, with reduction of QRS duration and with equal or greater effectiveness than biventricular pacing. Based on these results, many Italian electrophysiologists have changed the stimulation target from the right ventricular common myocardium to CSP. The two techniques with greater clinical impact are the His bundle stimulation and the left bundle branch pacing. The latter, in particular, because of its easier implantation technique and better electric parameters, is spreading like wildfire and is representing a real revolution in the cardiac pacing field. However, despite the growing amount of data, until now, the European Society of Cardiology guidelines give a very limited role to CSP.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Bundle-Branch Block , Treatment Outcome , Electrocardiography/methods , Heart Conduction System , Cardiac Resynchronization Therapy/methods , Myocardium , Heart Failure/therapy
9.
J Am Heart Assoc ; 13(9): e034004, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38639381

ABSTRACT

BACKGROUND: An epicardial connection (EC) through the intercaval bundle (EC-ICB) between the right pulmonary vein (RPV) and right atrium (RA) is one of the reasons for the need for carina ablation for PV isolation and may reduce the acute and chronic success of PV isolation. We evaluated the intra-atrial activation sequence during RPV pacing after failure of ipsilateral RPV isolation and sought to identify specific conduction patterns in the presence of EC-ICB. METHODS AND RESULTS: This study included 223 consecutive patients who underwent initial catheter ablation of atrial fibrillation. If the RPV was not isolated using circumferential ablation or reconnected during the waiting period, an exit map was created during mid-RPV carina pacing. If the earliest site on the exit map was the RA, the patient was classified into the EC-ICB group. The exit map, intra-atrial activation sequence, and RPV-high RA time were evaluated. First-pass isolation of the RPV was not achieved in 36 patients (16.1%), and 22 patients (9.9%) showed reconnection. Twelve and 28 patients were classified into the EC-ICB and non-EC-ICB groups, respectively, after excluding those with multiple ablation lesion sets or incomplete mapping. The intra-atrial activation sequence showed different patterns between the 2 groups. The RPV-high RA time was significantly shorter in the EC-ICB than in the non-EC-ICB group (69.2±15.2 versus 148.6±51.2 ms; P<0.001), and RPV-high RA time<89.0 ms was highly predictive of the existence of an EC-ICB (sensitivity, 91.7%; specificity, 89.3%). CONCLUSIONS: An EC-ICB can be effectively detected by intra-atrial sequencing during RPV pacing, and an RPV-high RA time of <89.0 ms was highly predictive.


Subject(s)
Atrial Fibrillation , Cardiac Pacing, Artificial , Catheter Ablation , Heart Atria , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Female , Male , Catheter Ablation/methods , Middle Aged , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Cardiac Pacing, Artificial/methods , Aged , Heart Atria/physiopathology , Heart Atria/surgery , Treatment Outcome , Retrospective Studies , Pericardium/surgery , Pericardium/physiopathology , Heart Conduction System/physiopathology , Action Potentials , Electrophysiologic Techniques, Cardiac , Heart Rate/physiology
10.
Tex Heart Inst J ; 51(1)2024 04 02.
Article in English | MEDLINE | ID: mdl-38564374

ABSTRACT

This report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular block. The atrioventricular block was resolved spontaneously. Pacing morphology was suggestive of right bundle branch pacing. Neither 2:1 atrioventricular block nor conduction system pacing has previously been a reported outcome of right ventricular leadless pacemaker implantation. The report demonstrates that conduction system pacing with leadless devices is achievable. Further study of techniques, limitations, and complications related to intentional right ventricular leadless conduction system pacing is warranted.


Subject(s)
Atrioventricular Block , Pacemaker, Artificial , Humans , Young Adult , Adult , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Cardiac Pacing, Artificial/methods , Pacemaker, Artificial/adverse effects , Heart Conduction System , Heart Ventricles , Treatment Outcome
11.
Am J Cardiol ; 221: 129-130, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38643927

ABSTRACT

Atrial fibrillation (AF) was largely ignored by cardiac electrophysiologists until it was first suggested in 1998 that it might be amenable to catheter ablation. In the 25 years since then, a vast body of knowledge has emerged, initially reporting the "hypes and hopes" that ablation was appropriate for all but more recently acknowledging that not all patients benefit from this approach. The AF "epidemic" and more holistic understanding of the complex contributors to its development question whether it is even meaningful to consider AF a single condition that is always responsive to ablation management. In this issue, Masuda et al11 provide novel insights into the electrophysiologic "footprints" that they found in the body of the left atrium of patients who underwent a second ablation procedure after achieving pulmonary vein isolation. In conclusion, the findings require prospective validation but may show a way of achieving antiarrhythmic success in a cohort of patients responding unpredictably to current ablation strategies.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Humans , Catheter Ablation/methods , Pulmonary Veins/surgery , Heart Conduction System/physiopathology , Heart Atria/physiopathology , Electrophysiologic Techniques, Cardiac/methods
12.
Cardiovasc Toxicol ; 24(5): 472-480, 2024 May.
Article in English | MEDLINE | ID: mdl-38630336

ABSTRACT

The challenge posed by opioid overdose has become a significant concern for health systems due to the complexities associated with drug prohibition, widespread clinical use, and potential abuse. In response, healthcare professionals have primarily concentrated on mitigating the hallucinogenic and respiratory depressant consequences of opioid overdose to minimize associated risks. However, it is crucial to acknowledge that most opioids possess the capacity to prolong the QT interval, particularly in cases of overdose, thereby potentially resulting in severe ventricular arrhythmias and even sudden death if timely intervention is not implemented. Consequently, alongside addressing the typical adverse effects of opioids, it is imperative to consider their cardiotoxicity. To enhance comprehension of the correlation between opioids and arrhythmias, identify potential targets for prompt intervention, and mitigate the hazards associated with clinical utilization, an exploration of the interaction between drugs and ion channels, as well as their underlying mechanisms, becomes indispensable. This review primarily concentrates on elucidating the impact of opioid drugs on diverse ion channels, investigating recent advancements in this domain, and attaining a deeper understanding of the mechanisms underlying the prolongation of the QT interval by opioid drugs, along with potential interventions.


Subject(s)
Analgesics, Opioid , Cardiotoxicity , Long QT Syndrome , Humans , Long QT Syndrome/chemically induced , Long QT Syndrome/physiopathology , Analgesics, Opioid/adverse effects , Animals , Risk Assessment , Risk Factors , Heart Rate/drug effects , Action Potentials/drug effects , Heart Conduction System/drug effects , Heart Conduction System/physiopathology , Ion Channels/metabolism , Ion Channels/drug effects , Opiate Overdose/physiopathology
14.
Cardiovasc Pathol ; 70: 107626, 2024.
Article in English | MEDLINE | ID: mdl-38458505

ABSTRACT

Iatrogenic damage to the cardiac conduction system (CCS) remains a significant risk during congenital heart surgery. Current surgical best practice involves using superficial anatomical landmarks to locate and avoid damaging the CCS. Prior work indicates inherent variability in the anatomy of the CCS and supporting tissues. This study introduces high-resolution, 3D models of the CCS in normal pediatric human hearts to evaluate variability in the nodes and surrounding structures. Human pediatric hearts were obtained with an average donor age of 2.7 days. A pipeline was developed to excise, section, stain, and image atrioventricular (AVN) and sinus nodal (SN) tissue regions. A convolutional neural network was trained to enable precise multi-class segmentation of whole-slide images, which were subsequently used to generate high- resolution 3D tissue models. Nodal tissue region models were created. All models (10 AVN, 8 SN) contain tissue composition of neural tissue, vasculature, and nodal tissues at micrometer resolution. We describe novel nodal anatomical variations. We found that the depth of the His bundle in females was on average 304 µm shallower than those of male patients. These models provide surgeons with insight into the heterogeneity of the nodal regions and the intricate relationships between the CCS and surrounding structures.


Subject(s)
Atrioventricular Node , Imaging, Three-Dimensional , Humans , Female , Male , Infant, Newborn , Atrioventricular Node/anatomy & histology , Models, Cardiovascular , Sinoatrial Node/anatomy & histology , Bundle of His/physiopathology , Neural Networks, Computer , Sex Factors , Age Factors , Heart Conduction System/physiopathology
15.
Heart Rhythm ; 21(6): 956-957, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38431023
17.
18.
Acta Cardiol ; 79(3): 367-373, 2024 May.
Article in English | MEDLINE | ID: mdl-38441069

ABSTRACT

BACKGROUND: Conduction system disorders represent a frequent complication in patients undergoing surgical (surgical aortic valve replacement, SAVR) or percutaneous (transcatheter aortic valve implantation, TAVI) aortic valve replacement. The purpose of this survey was to evaluate experienced operators approach in this clinical condition. METHODS: This survey was independently conducted by the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) and it consisted of 24 questions regarding the respondents' profile, the characteristics of participating centres, and conduction disease management in different scenarios. RESULTS: Fifty-five physicians from 55 Italian arrhythmia centres took part in the survey. Prophylactic pacemaker implantation is rare. In case of persistent complete atrioventricular block (AVB), 49% and 73% respondents wait less than one week before implanting a definitive pacemaker after SAVR and TAVI, respectively. In case of second degree AVB, the respondents wait some days more for definitive implantation. Respondents consider bundle branch blocks, in particular pre-existing left bundle branch block (LBBB), the worst prognostic factors for pacemaker implantation after TAVI. The implanted valve type is considered a relevant element to evaluate. In patients with new-onset LBBB and severe/moderate left ventricular systolic dysfunction, respondents would implant a biventricular pacemaker in 100/55% of cases, respectively. CONCLUSIONS: Waiting time before a definitive pacemaker implantation after aortic valve replacement has reduced compared to the past, and it is anticipated in TAVI vs. SAVR. Bundle branch blocks are considered the worse prognostic factor for pacemaker implantation after TAVI. The type of pacemaker implanted in new-onset LBBB patients without severe left ventricular systolic dysfunction is heterogeneous.


Subject(s)
Transcatheter Aortic Valve Replacement , Humans , Italy/epidemiology , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Cardiac Conduction System Disease/therapy , Cardiac Conduction System Disease/diagnosis , Cardiac Conduction System Disease/epidemiology , Aortic Valve Disease/surgery , Surveys and Questionnaires , Cardiac Pacing, Artificial/methods , Cardiac Pacing, Artificial/statistics & numerical data , Societies, Medical , Pacemaker, Artificial , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/adverse effects , Female , Male , Aortic Valve/surgery , Disease Management , Heart Conduction System/physiopathology
19.
Curr Top Dev Biol ; 156: 157-200, 2024.
Article in English | MEDLINE | ID: mdl-38556422

ABSTRACT

The heart is the first organ to form during embryonic development, establishing the circulatory infrastructure necessary to sustain life and enable downstream organogenesis. Critical to the heart's function is its ability to initiate and propagate electrical impulses that allow for the coordinated contraction and relaxation of its chambers, and thus, the movement of blood and nutrients. Several specialized structures within the heart, collectively known as the cardiac conduction system (CCS), are responsible for this phenomenon. In this review, we discuss the discovery and scientific history of the mammalian cardiac conduction system as well as the key genes and transcription factors implicated in the formation of its major structures. We also describe known human diseases related to CCS development and explore existing challenges in the clinical context.


Subject(s)
Heart Conduction System , Heart , Animals , Humans , Organogenesis , Mammals