Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 8.918
Filter
1.
Iran J Med Sci ; 49(6): 359-368, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38952641

ABSTRACT

Background: Heart transplantation is the preferred treatment for end-stage heart failure. This study investigated the intra-operative risk factors affecting post-transplantation mortality. Methods: This single-center retrospective cohort study examined 239 heart transplant patients over eight years, from 2011-2019, at the oldest dedicated cardiovascular center, Shahid Rajaee Hospital (Tehran, Iran). The primary evaluated clinical outcomes were rejection, readmission, and mortality one month and one year after transplantation. For data analysis, univariate logistic regression analyses were conducted. Results: In this study, 107 patients (43.2%) were adults, and 132 patients (56.8%) were children. Notably, reoperation due to bleeding was a significant predictor of one-month mortality in both children (OR=7.47, P=0.006) and adults (OR=172.12, P<0.001). Moreover, the need for defibrillation significantly increased the risk of one-month mortality in both groups (children: OR=38.00, P<0.001; adults: OR=172.12, P<0.001). Interestingly, readmission had a protective effect against one-month mortality in both children (OR=0.02, P<0.001) and adults (OR=0.004, P<0.001). Regarding one-year mortality, the use of extracorporeal membrane oxygenation (ECMO) was associated with a higher risk in both children (OR=7.64, P=0.001) and adults (OR=12.10, P<0.001). For children, reoperation due to postoperative hemorrhage also increased the risk (OR=5.14, P=0.020), while defibrillation was a significant risk factor in both children and adults (children: OR=22.00, P<0.001; adults: OR=172.12, P<0.001). The median post-surgery survival was 22 months for children and 24 months for adults. Conclusion: There was no correlation between sex and poorer outcomes. Mortality at one month and one year after transplantation was associated with the following risk factors: the use of ECMO, reoperation for bleeding, defibrillation following cross-clamp removal, and Intensive Care Unit (ICU) stay. Readmission, on the other hand, had a weak protective effect.


Subject(s)
Heart Transplantation , Humans , Heart Transplantation/statistics & numerical data , Heart Transplantation/methods , Heart Transplantation/mortality , Heart Transplantation/adverse effects , Heart Transplantation/trends , Male , Female , Risk Factors , Retrospective Studies , Iran/epidemiology , Child , Adult , Middle Aged , Patient Readmission/statistics & numerical data , Adolescent , Child, Preschool , Reoperation/statistics & numerical data , Reoperation/mortality , Reoperation/methods , Young Adult , Postoperative Complications/mortality , Heart Failure/mortality , Heart Failure/surgery
2.
Ann Card Anaesth ; 27(3): 260-262, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38963364

ABSTRACT

ABSTRACT: Venovenous (VV) ECMO is rarely used during decompensated circulatory states. Although VA ECMO is the routine option, VV ECMO may be an option in selected patients. We present a case of pulmonary edema due to acute heart failure in a patient 4- and 12-year post-lung transplantation who received VV ECMO. Using a thoughtful cannulation strategy, VV ECMO, and aggressive ultrafiltration, the patient was successfully decannulated, extubated, and discharged from the hospital. In cardiogenic pulmonary edema, VV ECMO represents an additional, and likely under-utilized tool, especially in patients who are at high risk for ventilator-associated lung injury. Cannula location and size should be given additional consideration to potentially transition to V-AV ECMO configuration if necessary.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart Failure , Lung Transplantation , Humans , Extracorporeal Membrane Oxygenation/methods , Heart Failure/surgery , Heart Failure/therapy , Heart Failure/complications , Male , Pulmonary Edema/etiology , Pulmonary Edema/therapy , Middle Aged , Acute Disease , Chronic Disease , Postoperative Complications/therapy , Postoperative Complications/etiology
3.
Exp Clin Transplant ; 22(5): 386-391, 2024 May.
Article in English | MEDLINE | ID: mdl-38970282

ABSTRACT

OBJECTIVES: Heart transplant is the most effective treatment in patients with advanced heart failure who are refractory to medical treatment. The brain death interval and type of inotrope We assessed the effects of these parameters on heart transplant outcomes. MATERIALS AND METHODS: In this follow-up study, we followed heart transplant recipients for 1 year to study patient survival, ejection fraction, adverse events, and organ rejection. We evaluated follow-up results on time from brainstem death test to the cross-clamp placement, as well as the type of inotrope used. RESULTS: Our study enrolled 54 heart transplant candidates. The inotrope dose was 3.66 ± 0.99 µg/kg/min, and the most used inotrope, with 28 cases (51.9%), was related to dopamine. Six cases (11.1%) of death and 1 case of infection after transplant were observed in recipients. The average ejection fraction of transplanted hearts before transplant, instantly at time of transplant, and 1 month, 6 months, and 1 year after transplant was 54.9 ± 0.68, 52.9 ± 10.4, 51.9 ± 10.7, 50.1 ± 10.9, and 46.8 ± 17, respectively; this decreasing trend over time was significant (P =.001). Furthermore, ejection fraction changes following transplant did not differ significantly in transplanted hearts regarding brain death interval and type of inotrope used. CONCLUSIONS: Our study revealed that cardiac output of a transplanted heart may decrease over time and the time elapsed from brain death, and both dopamine and norepinephrine could have negligible effects on cardiac function.


Subject(s)
Brain Death , Cardiotonic Agents , Heart Failure , Heart Transplantation , Humans , Heart Transplantation/adverse effects , Heart Transplantation/mortality , Time Factors , Male , Female , Middle Aged , Treatment Outcome , Adult , Heart Failure/physiopathology , Heart Failure/surgery , Heart Failure/diagnosis , Heart Failure/mortality , Cardiotonic Agents/therapeutic use , Cardiotonic Agents/adverse effects , Follow-Up Studies , Risk Factors , Stroke Volume/drug effects , Ventricular Function, Left/drug effects , Dopamine , Graft Rejection/prevention & control , Graft Rejection/immunology
4.
J Vis Exp ; (208)2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38949319

ABSTRACT

Right ventricular (RV) failure caused by pressure overload is strongly associated with morbidity and mortality in a number of cardiovascular and pulmonary diseases. The pathogenesis of RV failure is complex and remains inadequately understood. To identify new therapeutic strategies for the treatment of RV failure, robust and reproducible animal models are essential. Models of pulmonary trunk banding (PTB) have gained popularity, as RV function can be assessed independently of changes in the pulmonary vasculature. In this paper, we present a murine model of RV pressure overload induced by PTB in 5-week-old mice. The model can be used to induce different degrees of RV pathology, ranging from mild RV hypertrophy to decompensated RV failure. Detailed protocols for intubation, PTB surgery, and phenotyping by echocardiography are included in the paper. Furthermore, instructions for customizing instruments for intubation and PTB surgery are given, enabling fast and inexpensive reproduction of the PTB model. Titanium ligating clips were used to constrict the pulmonary trunk, ensuring a highly reproducible and operator-independent degree of pulmonary trunk constriction. The severity of PTB was graded by using different inner ligating clip diameters (mild: 450 µm and severe: 250 µm). This resulted in RV pathology ranging from hypertrophy with preserved RV function to decompensated RV failure with reduced cardiac output and extracardiac manifestations. RV function was assessed by echocardiography at 1 week and 3 weeks after surgery. Examples of echocardiographic images and results are presented here. Furthermore, results from right heart catheterization and histological analyses of cardiac tissue are shown.


Subject(s)
Disease Models, Animal , Hypertrophy, Right Ventricular , Animals , Mice , Hypertrophy, Right Ventricular/etiology , Hypertrophy, Right Ventricular/diagnostic imaging , Hypertrophy, Right Ventricular/physiopathology , Pulmonary Artery/surgery , Pulmonary Artery/physiopathology , Heart Failure/etiology , Heart Failure/surgery , Heart Failure/physiopathology , Ventricular Dysfunction, Right/etiology , Ventricular Dysfunction, Right/physiopathology , Ventricular Dysfunction, Right/diagnostic imaging , Male , Echocardiography/methods , Mice, Inbred C57BL
5.
J Cardiothorac Surg ; 19(1): 408, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951889

ABSTRACT

Right heart failure is a common complication after cardiac surgery, and its mortality remains high. The medical management and veno-arterial extracorporeal membrane oxygenation has shown significant improvement in the majority of cases. However, a minority of patients may still require long-term mechanical circulatory support or heart transplantation. Balloon atrial septostomy is a new method for the prevention and treatment of right heart failure, which may avoid the patient's dependence on mechanical circulatory support. We used this method to try to treat patients with right heart failure after cardiac surgery, and all received good benefits. Therefore, we selected several representative cases to report, in order to guide other qualified cardiac surgeons to carry out relevant clinical practice.


Subject(s)
Cardiac Surgical Procedures , Heart Failure , Postoperative Complications , Humans , Heart Failure/surgery , Male , Cardiac Surgical Procedures/adverse effects , Cardiac Surgical Procedures/methods , Female , Postoperative Complications/prevention & control , Middle Aged , Atrial Septum/surgery , Aged , Adult , Catheterization/methods , Heart Atria/surgery
6.
ASAIO J ; 70(7): 616-620, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38985982

ABSTRACT

Ventricular assist devices (VADs) have been increasingly implanted in pediatric patients. Paracorporeal VADs are generally chosen when intracorporeal continuous (IC) devices are too large. Superiority between IC and paracorporeal pulsatile (PP) devices remains unclear in smaller pediatric patients. Our study analyzes outcomes of IC and PP VADs in pediatric patients who could be considered for either of these options. Using the Advanced Cardiac Therapies Improving Outcomes Network (ACTION) database, we identified children between 10 and 30 kg who received a VAD between June 2018 and September 2021. Survival and stroke outcomes were analyzed based on VAD type. There were 41 patients in the IC group and 54 patients in the PP group. Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile at the time of implant was higher in the PP cohort ( p < 0.02). The PP cohort was younger ( p < 0.001) and smaller ( p < 0.001) than the IC cohort. The diagnosis was similar between cohorts. Overall survival was similar between groups. Stroke was more common in the PP cohort, but did not reach statistical significance ( p = 0.07). Discharge was possible only in the IC group, but the discharge rate was low (9.5%). Direct comparisons remain challenging given differences in INTERMACS profiles, age, and size.


Subject(s)
Heart-Assist Devices , Humans , Male , Female , Infant , Child, Preschool , Treatment Outcome , Retrospective Studies , Heart Failure/surgery , Heart Failure/therapy , Child , Stroke , Registries/statistics & numerical data , Body Weight
7.
Clin Transplant ; 38(7): e15404, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39023077

ABSTRACT

BACKGROUND: The axillary artery (AX) access for intra-aortic balloon pump (IABP) as a bridge to heart transplant (HT) allows mobility while awaiting a suitable donor. As end-stage heart failure patients often have an implantable cardioverter defibrillator (ICD) on the left side, the left AX approach may be avoided due to the perception of difficult access and proximity of two devices. We aimed to evaluate the outcomes of patients bridged to HT with a left-sided AX IABP with or without ipsilateral ICDs. METHODS: We retrospectively reviewed HT candidates at our institution supported by left-sided axillary IABP from November 2019 to February 2024, dividing them into two groups based on the presence (Group ICD, n = 48) or absence (Group No-ICD, N = 19) of an ipsilateral left-sided ICD. The exposure time was defined as the time from skin incision to the beginning of anastomoses of a Dacron graft. RESULTS: Technical success was achieved in 100% of the cohort, with median exposure times for AX access similar between groups (ICD, 12 [7.8, 18.2] vs. No ICD, 11 [7, 19] min; p = 0.75). The rate of procedural adverse events, such as significant access site bleeding and ipsilateral limb ischemia, did not significantly differ between both groups. Device malfunction rates were comparable (ICD, 29.2% vs. No ICD, 15.8%; p = 0.35). Posttransplant, in-hospital mortality, severe primary graft dysfunction, and stroke rates were comparable in both groups. CONCLUSION: The presence of an ipsilateral left-sided ICD does not adversely impact the procedural efficacy, complication rates, or posttransplant outcomes of left-sided AX IABP insertion in HT candidates.


Subject(s)
Defibrillators, Implantable , Heart Failure , Heart Transplantation , Intra-Aortic Balloon Pumping , Humans , Female , Male , Retrospective Studies , Middle Aged , Heart Failure/surgery , Heart Failure/therapy , Follow-Up Studies , Prognosis , Axillary Artery
8.
A A Pract ; 18(7): e01826, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-39008443

ABSTRACT

Right ventricular myocardial work is an echocardiographic technique yielding significant insights into cardiac mechanics, energetics, and efficiency. Combining right ventricular myocardial strain with loading conditions correlates with invasively measured myocardial work and myocardial oxygen consumption. This method has not yet been described intraoperatively by transesophageal echocardiography. We describe this technique during a left ventricular assist device implantation. This case demonstrates that right ventricular myocardial work indices can be monitored intraoperatively and might assist decisions during left ventricular assist device implantation.


Subject(s)
Echocardiography, Transesophageal , Heart-Assist Devices , Humans , Male , Middle Aged , Ventricular Function, Right/physiology , Heart Ventricles , Heart Failure/surgery , Heart Failure/therapy , Heart Failure/physiopathology
9.
Transpl Int ; 37: 13191, 2024.
Article in English | MEDLINE | ID: mdl-39015154

ABSTRACT

Little is known either about either physical activity patterns, or other lifestyle-related prevention measures in heart transplantation (HTx) recipients. The history of HTx started more than 50 years ago but there are still no guidelines or position papers highlighting the features of prevention and rehabilitation after HTx. The aims of this scientific statement are (i) to explain the importance of prevention and rehabilitation after HTx, and (ii) to promote the factors (modifiable/non-modifiable) that should be addressed after HTx to improve patients' physical capacity, quality of life and survival. All HTx team members have their role to play in the care of these patients and multidisciplinary prevention and rehabilitation programmes designed for transplant recipients. HTx recipients are clearly not healthy disease-free subjects yet they also significantly differ from heart failure patients or those who are supported with mechanical circulatory support. Therefore, prevention and rehabilitation after HTx both need to be specifically tailored to this patient population and be multidisciplinary in nature. Prevention and rehabilitation programmes should be initiated early after HTx and continued during the entire post-transplant journey. This clinical consensus statement focuses on the importance and the characteristics of prevention and rehabilitation designed for HTx recipients.


Subject(s)
Heart Failure , Heart Transplantation , Quality of Life , Humans , Consensus , Europe , Exercise , Heart Failure/rehabilitation , Heart Failure/surgery , Heart Transplantation/adverse effects , Societies, Medical
14.
Article in English | MEDLINE | ID: mdl-38967795

ABSTRACT

This case report illustrates how to implant a central paracorporeal temporary biventricular assist device in a 17-year-old patient with acute heart failure due to a fulminant form of coronavirus disease 2019 myocarditis. The procedure was carried out after prior veno-arterial extracorporeal membrane oxygenation support. Myocardial biopsies and biventricular assist device explants are also included in the report. The patient was weaned on postoperative day 6 and discharged without any significant complications. One year after the event, the patient remains asymptomatic with normal biventricular function and a normal lifestyle.


Subject(s)
COVID-19 , Heart Failure , Heart-Assist Devices , Myocarditis , Humans , Myocarditis/surgery , COVID-19/complications , Adolescent , Heart Failure/surgery , Male , SARS-CoV-2 , Extracorporeal Membrane Oxygenation/methods , Device Removal/methods
17.
J Int Med Res ; 52(6): 3000605241258474, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38901839

ABSTRACT

The gold standard therapy for end-stage heart failure is cardiac transplantation. However, in the face of a donor shortage, a mechanical assist device such as the left ventricular assist device HeartMate 3 (Abbott Laboratories, Abbott Park, IL, USA) serves as bridging therapy to transplantation and/or destination therapy. Current guidelines recommend anticoagulation with a vitamin K antagonist in combination with low-dose aspirin. We herein report a challenging anticoagulation regimen in a patient with a HeartMate 3 in whom systemic anticoagulation with warfarin was not feasible for 4 years because of low compatibility and a rare X-factor deficiency. This is a rare hematological disorder, estimated to affect approximately 1 in every 500,000 to 1,000,000 people in the general population. The patient finally received a modified anticoagulation regimen involving the combination of rivaroxaban and clopidogrel without warfarin. Under this regimen, the patient remained free of thromboembolic complications for 4 years with in situ placement of the left ventricular assist device. This case illustrates that under specific circumstances, long-term absence of warfarin therapy is feasible in patients with a HeartMate 3.


Subject(s)
Anticoagulants , Heart-Assist Devices , Thromboembolism , Warfarin , Humans , Heart-Assist Devices/adverse effects , Warfarin/therapeutic use , Warfarin/administration & dosage , Thromboembolism/etiology , Thromboembolism/prevention & control , Anticoagulants/therapeutic use , Anticoagulants/administration & dosage , Male , Heart Failure/surgery , Middle Aged , Clopidogrel/administration & dosage , Clopidogrel/therapeutic use , Clopidogrel/adverse effects , Rivaroxaban/administration & dosage , Rivaroxaban/therapeutic use , Withholding Treatment
18.
Transpl Int ; 37: 12750, 2024.
Article in English | MEDLINE | ID: mdl-38881801

ABSTRACT

Patients with end-stage heart disease who undergo a heart transplant frequently have simultaneous kidney insufficiency, therefore simultaneous heart and kidney transplantation is an option and it is necessary to understand its characteristics and long-term variables. The recipient characteristics and operative and long-term variables were assessed in a meta-analysis. A total of 781 studies were screened, and 33 were thoroughly reviewed. 15 retrospective cohort studies and 376 patients were included. The recipient's mean age was 51.1 years (95% CI 48.52-53.67) and 84% (95% CI 80-87) were male. 71% (95% CI 59-83) of the recipients were dialysis dependent. The most common indication was ischemic cardiomyopathy [47% (95% CI 41-53)] and cardiorenal syndrome [22% (95% CI 9-35)]. Also, 33% (95% CI 20-46) of the patients presented with delayed graft function. During the mean follow-up period of 67.49 months (95% CI 45.64-89.33), simultaneous rejection episodes of both organ allografts were described in 5 cases only. Overall survival was 95% (95% CI 88-100) at 30 days, 81% (95% CI 76-86) at 1 year, 79% (95% CI 71-87) at 3, and 71% (95% CI 59-83) at 5 years. Simultaneous heart and kidney transplantation is an important option for concurrent cardiac and renal dysfunction and has acceptable rejection and survival rates.


Subject(s)
Graft Rejection , Graft Survival , Heart Transplantation , Kidney Transplantation , Humans , Male , Middle Aged , Female , Cardio-Renal Syndrome/surgery , Delayed Graft Function , Retrospective Studies , Kidney Failure, Chronic/surgery , Kidney Failure, Chronic/complications , Heart Failure/surgery , Heart Failure/mortality , Treatment Outcome
19.
Pediatr Transplant ; 28(5): e14802, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38853134

ABSTRACT

BACKGROUND: Limited research exists on the influence of social determinants of health (SDOH) on outcomes in pediatric patients with advanced heart failure receiving mechanical circulatory support. METHODS: Linkage of the Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) and Society of Thoracic Surgeon's Congenital Heart Surgery Database (STS-CHSD) identified pediatric patients who underwent ventricular assist device (VAD) implantation from 2012 to 2022 with available residential zip codes. Utilizing the available zip codes, each patient was assigned a Childhood Opportunity Index (COI) score. Level of childhood opportunity, race, and insurance type were used as proxies for SDOH. Major outcomes included death, transplant, alive with device, and recovery. Secondary outcomes were adverse events. Statistical analyses were performed using the Kaplan-Meier survival, competing risk analyses, and multivariable Cox proportional hazards model. RESULTS: Three hundred seventeen patients were included in the study. Childhood opportunity level and insurance status did not significantly impact morbidity or mortality after VAD implantation. White race was associated with reduced 1-year survival (71% in White vs. 87% in non-White patients, p = 0.05) and increased risk of pump thrombosis (p = 0.02). CONCLUSION: Childhood opportunity level and insurance status were not linked to morbidity and mortality in pediatric patients after VAD implantation. Notably, White race was associated with higher mortality rates. The study underscores the importance of considering SDOH in evaluating advanced therapies for pediatric heart failure and emphasizes the need for accurate socioeconomic data collection in future studies and national registries.


Subject(s)
Heart Failure , Heart-Assist Devices , Registries , Social Determinants of Health , Humans , Female , Male , Child , Heart Failure/surgery , Heart Failure/therapy , Child, Preschool , Infant , Adolescent , Retrospective Studies , Kaplan-Meier Estimate , Treatment Outcome , United States/epidemiology , Proportional Hazards Models , Infant, Newborn
SELECTION OF CITATIONS
SEARCH DETAIL
...