Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.174
Filter
1.
Braz J Cardiovasc Surg ; 39(4): e20230278, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748990

ABSTRACT

CLINICAL DATA: Female, seven years old, referred to our service complaining about congestive heart failure symptoms due to mitral valve regurgitation and atrial septal defect. Technical description: Echocardiographic findings compatible with Barlow's disease and atrial septal defect, ostium secundum type. OPERATION: She was submitted to mitral valvuloplasty with chordal shortening and prosthetic posterior ring (Gregori-Braile®) along with patch atrioseptoplasty. COMMENTS: Mitral valve regurgitation is a rare congenital heart disease and Barlow's disease is probably rarer. Mitral valve repair is the treatment of choice.


Subject(s)
Heart Septal Defects, Atrial , Mitral Valve Insufficiency , Humans , Heart Septal Defects, Atrial/surgery , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/complications , Female , Child , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Echocardiography , Mitral Valve Prolapse/surgery , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/complications
2.
Echocardiography ; 41(5): e15823, 2024 May.
Article in English | MEDLINE | ID: mdl-38678585

ABSTRACT

The morphologic features of the multiple atrial septal defects assessed by TTE-based 3D imaging were similar to those by 3D-TEE. TTE-based 3D model had excellent visibility, allowing observation of 3D structure of the rims of the defects. It may be useful method for assessment of the multiple atrial septal defects.


Subject(s)
Echocardiography, Three-Dimensional , Heart Septal Defects, Atrial , Vena Cava, Inferior , Humans , Heart Septal Defects, Atrial/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Vena Cava, Inferior/diagnostic imaging , Female , Male , Adult
5.
J Cardiovasc Med (Hagerstown) ; 25(4): 311-317, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38488065

ABSTRACT

AIMS: We present the experience and long-term results of intracardiac echocardiography (ICE)-guided closure of ostium secundum atrial septal defects (ASDs) in two Italian centers and investigate its systematic applicability as the gold standard in routine clinical practice. METHODS: We retrospectively evaluated all consecutive patients who underwent an ASD percutaneous closure procedure from March 2008 to February 2020. All patients underwent a preprocedural transesophageal echocardiography (TEE) evaluation. The closures were carried out under fluoroscopic and ICE guidance. A follow-up visit was performed at 1, 3 and 12 months, followed by telephone evaluations approximately every 2 years. RESULTS: Sixty-six patients (29% male individuals), mean age 43 ±â€Š16 years, were treated. In 15 cases, the TEE defect diameter was less than 10 mm, and in 8 of these patients, the ICE intraprocedural sizing increased the maximum diameter by more than 5 mm. Sizing balloon of the defect was performed in 51 cases; 2 patients received an ASD 38 mm device. Eight patients had multiple defects; in three of these, it was necessary to apply two devices. Four patients showed nonsignificant residual shunt; no complications related to the use of ICE were observed. One patient presented the migration of the ASD device into the abdominal aorta, percutaneously retrieved with a snare. No major complications were recorded during the entire follow-up period. CONCLUSION: This study confirms that ICE monitoring during ASD percutaneous closure is well tolerated and effective; it might be achievable as a routine gold standard by operators willing to use ICE systematically in all transcatheter closure interventions of interatrial communications.


Subject(s)
Cardiac Catheterization , Heart Septal Defects, Atrial , Humans , Male , Adult , Middle Aged , Female , Retrospective Studies , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/therapy , Echocardiography, Transesophageal , Fluoroscopy , Treatment Outcome
8.
J Stroke Cerebrovasc Dis ; 33(6): 107664, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38428550

ABSTRACT

OBJECTIVES: Paradoxical embolism from right-to-left shunt through atrial septal defect (ASD) and patent foramen ovale (PFO) is a well-accepted cause of "cryptogenic" strokes (CS). To better understand the pathogenic role of ASD, we compared ASD patients with CS having a high and low likelihood of being PFO-related. METHODS: In the Acute Stroke Registry and Analysis of Lausanne, we calculated prevalence of PFO and ASD in CS patients undergoing echocardiography, and calculated odds ratios (OR) when compared to non-CS. Using the Risk of Paradoxical Embolism (RoPE) score, we divided CS PFO patients in high (HL-PFO, RoPE 8-10) and low-likelihood (LL-PFO, RoPE 0-4) PFO-related stroke. We then performed univariate comparison of epidemiological, clinical and radiological variables of ASD patients with both PFO groups. RESULTS: Among all CS, prevalence of ASD and PFO were 1.3% and 36.8% respectively. When compared to non-CS, ASD and PFO were associated with CS (OR of 5.2, CI= 1.6-16.6, and 2.8, CI= 2.1-3.8). Compared with HL-PFO, ASD patients were older, more often female, had more cardiovascular risk factors and silent strokes. Compared with LL-PFO, ASD patients were younger, more often female, and had less risk factors. No differences were found for clinical and radiological characteristics and clinical outcome. CONCLUSION: ASD is a rare stroke risk factor for CS. Since characteristics of such patients lie in-between high and low-likelihood paradoxical PFO-strokes, a thorough work-up for other stroke mechanisms is warranted. Individual evaluation of the likelihood of the ASD being causative for stroke may be preferable over routine ASD closure.


Subject(s)
Embolism, Paradoxical , Foramen Ovale, Patent , Heart Septal Defects, Atrial , Registries , Humans , Foramen Ovale, Patent/diagnostic imaging , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/epidemiology , Female , Male , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/epidemiology , Heart Septal Defects, Atrial/complications , Risk Factors , Middle Aged , Prevalence , Aged , Embolism, Paradoxical/epidemiology , Embolism, Paradoxical/diagnostic imaging , Embolism, Paradoxical/etiology , Risk Assessment , Adult , Stroke/epidemiology , Stroke/etiology , Stroke/diagnosis , Stroke/diagnostic imaging
9.
Catheter Cardiovasc Interv ; 103(5): 741-750, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38451154

ABSTRACT

BACKGROUND: The GCA is a well performing device in terms of efficacy despite complex anatomies (aortic rim <5 mm and ASD diameter >17 mm) with a good safety profile. AIMS: To evaluate atrial septal defect (ASD) features impacting on right disc device thrombosis in patients who underwent Gore Cardioform ASD Occluder (GCA) implantation. METHODS: A total of 44 consecutive patients undergoing percutaneous ASD with GCA device from January 2020 to September 2022 at our tertiary care Center were evaluated. The minimum follow-up was 6 months. RESULTS: The patients were stratified in two groups according to a cut-off value of ASD diameter equal to 20 mm at sizing balloon, derived from ROC analysis (AUC = 0.894; p = 0.024). Baseline characteristics were comparable between groups in terms of age, sex, weight, height, and interatrial septum dimensions. Patients with ASD > 20 mm (n = 9) had a higher ASD/device dimension ratio, both at echocardiography (p = 0.009) and at sizing balloon (p = 0.001), longer fluoroscopic time (p = 0.022), and higher incidence of device thrombosis (0.006). Right disc thrombosis was observed in three patients of the ASD > 20 mm group, always in the inferior portion of the right disc. On univariate analysis, ASD diameter at sizing balloon (OR 1.360; p = 0.036) was the only positive predictor of device thrombosis. CONCLUSIONS: Right disc thrombosis of the GCA device may be under-recognized at follow-up, hence deserving clinical attention, especially in those patients with larger ASD diameters.


Subject(s)
Heart Septal Defects, Atrial , Septal Occluder Device , Humans , Echocardiography, Transesophageal , Treatment Outcome , Cardiac Catheterization/adverse effects , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/therapy
11.
Cardiol Young ; 34(4): 919-921, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38410075

ABSTRACT

We report an uncommon case report of total anomalous pulmonary venous returns into the right atrium at the base of the superior caval vein's ostium without a sinus venosus defect, in situs solitus, without vertical vein or a posterior pulmonary venous confluence.


Subject(s)
Heart Septal Defects, Atrial , Pulmonary Veins , Scimitar Syndrome , Humans , Scimitar Syndrome/diagnostic imaging , Vena Cava, Superior/diagnostic imaging , Vena Cava, Superior/abnormalities , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/abnormalities , Heart Septal Defects, Atrial/diagnosis , Heart Septal Defects, Atrial/diagnostic imaging , Heart Atria/diagnostic imaging , Heart Atria/abnormalities
12.
Pediatr Cardiol ; 45(4): 710-721, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38366300

ABSTRACT

Atrial septal defects (ASDs) are common in neonates. Although past studies suggest ASDs  ≥ 3 mm in term neonates (TNs) are less likely to close, there is paucity of data regarding the natural history in preterm neonates (PNs), information that would inform surveillance. We sought to compare spontaneous closure rates and need for intervention for ASDs in TNs/near term (≥ 36 weeks) versus PNs (< 36 weeks). We included all TNs and PNs who underwent echocardiography at ≤ 1 month between 2010 and 2018 in our institution with an ASD ≥ 3 mm, without major congenital heart disease, and with repeat echocardiogram(s). Spontaneous resolution was defined as size diminution to < 3 mm or closure. We included 156 TNs (mean gestational age at birth 38.6 ± 1.4 weeks) and 156 PNs (29.6 ± 3.7 weeks) with a mean age at follow-up of 16 ± 19 and 15 ± 21 months, respectively (p = 0.76). Based on maximum color Doppler diameter, in TNs, ASD resolution occurred in 95% of small (3-5 mm), 87% of moderate (5.1-8 mm), and 60% of large (> 8 mm) defects; whereas, in PNs, resolution occurred in 79% of small, 76% of moderate, and 33% of large ASDs. There was a significant association between size and ASD resolution in TNs (p = 0.003), but not PNs (p = 0.17). Overall, ASD resolution rate was higher in TNs (89%) versus PNs (78%) (p = 0.009), and fewer TNs (1%) compared to PNs (7%) required ASD intervention (p = 0.02). Most ASDs identified in TNs and PNs spontaneously resolve. PNs, however, demonstrate lower ASD resolution and higher intervention rates within all size groups. These data should inform follow-up of affected neonates.


Subject(s)
Heart Septal Defects, Atrial , Infant, Newborn , Humans , Heart Septal Defects, Atrial/diagnostic imaging , Echocardiography , Ultrasonography, Doppler, Color , Treatment Outcome , Cardiac Catheterization
13.
Int Heart J ; 65(1): 155-158, 2024.
Article in English | MEDLINE | ID: mdl-38296570

ABSTRACT

Unroofed coronary sinus syndrome is a rare congenital cardiac anomaly, involving some anatomical variations. Approximately 60% of patients with unroofed coronary sinus syndrome have a concomitant atrial septal defect, which is termed unroofed coronary sinus atrial septal defect (CSASD). The precise detection of these abnormalities has been usually difficult with conventional echocardiography, mostly due to its small and complex structures. Herein, we report a case with unroofed coronary sinus atrial septal defect, in which preoperative contrast-enhanced computed tomography (CT) was useful in the operative decision making. We successfully repaired the defective roof of the coronary sinus with a bovine patch, while eliminating the inter-atrial shunt. The patient's postoperative course was uneventful with no residual shunt.


Subject(s)
Coronary Sinus , Heart Defects, Congenital , Heart Septal Defects, Atrial , Aged , Humans , Coronary Sinus/diagnostic imaging , Coronary Sinus/surgery , Coronary Sinus/abnormalities , Echocardiography , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Syndrome , Tomography, X-Ray Computed
18.
Echocardiography ; 41(1): e15724, 2024 01.
Article in English | MEDLINE | ID: mdl-38064288

ABSTRACT

BACKGROUND AND AIM: Our aim was to evaluate the fluoroscopy time (FT), procedure time (PT) safety and efficacy when using intracardiac echocardiography (ICE) in comparison to transesophageal echocardiography (TEE) guidance for transcatheter closure of Ostium Secundum Atrial Septal Defect (OS-ASD). METHOD: Ninety patients (n = 90) diagnosed with OS-ASD underwent transcatheter closure between March 2006 and October 2021. Fifty-seven patients were treated under ICE guidance, while 33 patients were treated under TEE guidance. RESULTS: Mean age was 43 ± 15 years and 42 ± 10 years in the ICE and TEE groups, respectively. The majority of patients had a centrally placed defect. Median FT was 8.40 min versus 11.70 min (p < .001) in the ICE group compared to the TEE group, respectively. Median PT was 43 min versus 94 min (p < .001) in the ICE group compared to the TEE group, respectively. Both ICE and TEE provided high quality images. All interventions were completed successfully, except for one patient in the ICE group who experienced a device migration, the development of atrial tachycardia in one patient and atrial fibrillation in two patients in the ICE group which spontaneously cardioverted. There were no other complications. CONCLUSION: This study on a consistent cohort of patients with OS-ASD undergoing percutaneous closure suggests that use of ICE is safe and efficacious. Compared to TEE, ICE demonstrated significantly shorter FT and PT, decreasing the entire duration of the procedure and x-ray exposure. No relevant differences were observed in terms of success rate and complications.


Subject(s)
Atrial Fibrillation , Heart Septal Defects, Atrial , Humans , Adult , Middle Aged , Echocardiography, Transesophageal/methods , Cardiac Catheterization/methods , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Fluoroscopy , Treatment Outcome
19.
Eur J Intern Med ; 120: 25-28, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38072687

ABSTRACT

Atrial septal defects (ASD) and Patent foramen ovale (PFO) represent the most common congenital heart diseases (CHD) adulthood. These two clinical entities, having different embryological origin, as well as clinical manifestations, clinical course and treatment must be carefully distinguished. Right heart failure and pulmonary hypertension are considered the major determinants of morbidity and mortality in ASD. Conversely, new pathophysiology concepts have been raised in the management of PFO as left atrium cardiopathy. New diagnostic tools, including cardiac magnetic resonance and intracardiac echocardiography have joint transthoracic and transesophageal echocardiography in the diagnostic definition of both ASD and PFO as well as in guiding their percutaneous closure. Moreover, several innovations have been developed in the field of percutaneous ASD and PFO closure devices including new evidence supporting the safety and efficacy of device-based closure. Aim of the present review is to present review we provided and update overview on ASD and PFO, focusing on the novel concepts regarding their pathophysiological and therapeutic aspects.


Subject(s)
Foramen Ovale, Patent , Heart Septal Defects, Atrial , Septal Occluder Device , Humans , Adult , Treatment Outcome , Foramen Ovale, Patent/diagnostic imaging , Foramen Ovale, Patent/surgery , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Echocardiography, Transesophageal , Heart Atria/diagnostic imaging , Cardiac Catheterization
20.
Radiol Med ; 129(1): 48-55, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38082195

ABSTRACT

OBJECT: The purpose of this study was to explore a machine learning-based residual networks (ResNets) model to detect atrial septal defect (ASD) on chest radiographs. METHODS: This retrospective study included chest radiographs consecutively collected at our hospital from June 2017 to May 2022. Qualified chest radiographs were obtained from patients who had finished echocardiography. These chest radiographs were labeled as positive or negative for ASD based on the echocardiographic reports and were divided into training, validation, and test dataset. Six ResNets models were employed to examine and compare by using the training dataset and was tuned using the validation dataset. The area under the curve, recall, precision and F1-score were taken as the evaluation metrics for classification result in the test dataset. Visualizing regions of interest for the ResNets models using heat maps. RESULTS: This study included a total of 2105 chest radiographs of children with ASD (mean age 4.14 ± 2.73 years, 54% male), patients were randomly assigned to training, validation, and test dataset with an 8:1:1 ratio. Healthy children's images were supplemented to three datasets in a 1:1 ratio with ASD patients. Following the training, ResNet-10t and ResNet-18D have a better estimation performance, with precision, recall, accuracy, F1-score, and the area under the curve being (0.92, 0.93), (0.91, 0.91), (0.90, 0.90), (0.91, 0.91) and (0.97, 0.96), respectively. Compared to ResNet-18D, ResNet-10t was more focused on the distribution of the heat map of the interest region for most chest radiographs from ASD patients. CONCLUSION: The ResNets model is feasible for identifying ASD through children's chest radiographs. ResNet-10t stands out as the preferable estimation model, providing exceptional performance and clear interpretability.


Subject(s)
Echocardiography , Heart Septal Defects, Atrial , Child , Child, Preschool , Female , Humans , Infant , Male , Heart Septal Defects, Atrial/diagnostic imaging , Machine Learning , Radiography , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...