Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 11.134
Filter
1.
Scand Cardiovasc J ; 58(1): 2347293, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38832868

ABSTRACT

OBJECTIVES: Minimally invasive cardiac surgery techniques are increasingly used but have longer cardiopulmonary bypass time, which may increase inflammatory response and negatively affect coagulation. Our aim was to compare biomarkers of inflammation and coagulation as well as transfusion rates after minimally invasive mitral valve repair and mitral valve surgery using conventional sternotomy. DESIGN: A prospective non-randomized study was performed enrolling 71 patients undergoing mitral valve surgery (35 right mini-thoracotomy and 36 conventional sternotomy procedures). Blood samples were collected pre- and postoperatively to assess inflammatory response. Thromboelastometry (ROTEM) was performed to assess coagulation, and transfusion rates were monitored. RESULTS: The minimally invasive group had longer cardiopulmonary bypass times compared to the sternotomy group: 127 min ([115-146] vs 79 min [65-112], p < 0.001) and were cooled to a lower temperature during cardiopulmonary bypass, 34 °C vs 36 °C (p = 0.04). IL-6 was lower in the minimally invasive group compared to the conventional sternotomy group when measured at the end of the surgical procedure, (38 [23-69] vs 61[41-139], p = 0.008), but no differences were found at postoperative day 1 or postoperative day 3. The transfusion rate was lower in the minimally invasive group (14%) compared to full sternotomy (35%, p = 0.04) and the chest tube output was reduced, (395 ml [190-705] vs 570 ml [400-1040], p = 0.04). CONCLUSIONS: Our data showed that despite the longer use of extra corporal circulation during surgery, minimally invasive mitral valve repair is associated with reduced inflammatory response, lower rates of transfusion, and reduced chest tube output.


Subject(s)
Biomarkers , Blood Coagulation , Blood Transfusion , Cardiopulmonary Bypass , Inflammation Mediators , Mitral Valve , Sternotomy , Thoracotomy , Humans , Prospective Studies , Female , Male , Biomarkers/blood , Middle Aged , Mitral Valve/surgery , Mitral Valve/physiopathology , Inflammation Mediators/blood , Cardiopulmonary Bypass/adverse effects , Aged , Treatment Outcome , Time Factors , Sternotomy/adverse effects , Thoracotomy/adverse effects , Thrombelastography , Interleukin-6/blood , Inflammation/blood , Inflammation/etiology , Inflammation/diagnosis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Diseases/surgery , Heart Valve Diseases/blood , Risk Factors
2.
BMC Cardiovasc Disord ; 24(1): 250, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38745119

ABSTRACT

OBJECTIVES: Prolonged mechanical ventilation (PMV) is a common complication following cardiac surgery linked to unfavorable patient prognosis and increased mortality. This study aimed to search for the factors associated with the occurrence of PMV after valve surgery and to develop a risk prediction model. METHODS: The patient cohort was divided into two groups based on the presence or absence of PMV post-surgery. Comprehensive preoperative and intraoperative clinical data were collected. Univariate and multivariate logistic regression analyses were employed to identify risk factors contributing to the incidence of PMV. Based on the logistic regression results, a clinical nomogram was developed. RESULTS: The study included 550 patients who underwent valve surgery, among whom 62 (11.27%) developed PMV. Multivariate logistic regression analysis revealed that age (odds ratio [OR] = 1.082, 95% confidence interval [CI] = 1.042-1.125; P < 0.000), current smokers (OR = 1.953, 95% CI = 1.007-3.787; P = 0.047), left atrial internal diameter index (OR = 1.04, 95% CI = 1.002-1.081; P = 0.041), red blood cell count (OR = 0.49, 95% CI = 0.275-0.876; P = 0.016), and aortic clamping time (OR = 1.031, 95% CI = 1.005-1.057; P < 0.017) independently influenced the occurrence of PMV. A nomogram was constructed based on these factors. In addition, a receiver operating characteristic (ROC) curve was plotted, with an area under the curve (AUC) of 0.782 and an accuracy of 0.884. CONCLUSION: Age, current smokers, left atrial diameter index, red blood cell count, and aortic clamping time are independent risk factors for PMV in patients undergoing valve surgery. Furthermore, the nomogram based on these factors demonstrates the potential for predicting the risk of PMV in patients following valve surgery.


Subject(s)
Nomograms , Predictive Value of Tests , Respiration, Artificial , Humans , Risk Factors , Male , Female , Middle Aged , Respiration, Artificial/adverse effects , Time Factors , Risk Assessment , Aged , Retrospective Studies , Treatment Outcome , Cardiac Surgical Procedures/adverse effects , Decision Support Techniques , Adult , Heart Valve Prosthesis Implantation/adverse effects , Heart Valves/surgery , Heart Valve Diseases/surgery , Age Factors
3.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38733575

ABSTRACT

OBJECTIVES: The aim of this study was to identify methodological variations leading to varied recommendations between the American College of Cardiology (ACC)/American Heart Association (AHA) and the European Society of Cardiology (ESC)/European Association for Cardio-Thoracic Surgery (EACTS) valvular heart disease guidelines and to suggest foundational steps towards standardizing guideline development. METHODS: An in-depth analysis was conducted to evaluate the methodologies used in developing the transatlantic guidelines for managing valvular heart disease. The evaluation was benchmarked against the standards proposed by the Institute of Medicine. RESULTS: Substantial discrepancies were noted in the methodologies utilized in development processes, including Writing Committee composition, evidence evaluation, conflict of interest management and voting processes. Furthermore, despite their mutual differences, both methodologies demonstrate notable deviations from the Institute of Medicine standards in several essential areas, including literature review and evidence grading. These dual variances likely influenced divergent treatment recommendations. For example, the ESC/EACTS recommends transcatheter edge-to-edge repair for patients with chronic severe mitral regurgitation ineligible for mitral valve surgery, while the ACC/AHA recommends transcatheter edge-to-edge repair based on anatomy, regardless of surgical risk. ESC/EACTS guidelines recommend a mechanical aortic prosthesis for patients under 60, while ACC/AHA guidelines recommend it for patients under 50. Notably, the ACC/AHA and ESC/EACTS guidelines have differing age cut-offs for surgical over transcatheter aortic valve replacement (<65 and <75 years, respectively). CONCLUSIONS: Variations in methodologies for developing clinical practice guidelines have resulted in different treatment recommendations that may significantly impact global practice patterns. Standardization of essential processes is vital to increase the uniformity and credibility of clinical practice guidelines, ultimately improving healthcare quality, reducing variability and enhancing trust in modern medicine.


Subject(s)
Heart Valve Diseases , Practice Guidelines as Topic , Humans , Heart Valve Diseases/surgery , Heart Valve Diseases/therapy , Practice Guidelines as Topic/standards , Evidence-Based Medicine/standards , Europe , Societies, Medical/standards , United States , Cardiology/standards
4.
Stat Med ; 43(13): 2641-2654, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38693582

ABSTRACT

Data on retrospective compensation claims for injuries caused by pharmaceutical drugs are prone to selection and reporting biases. Nevertheless, this case study of the antidiabetic drug benfluorex shows that such data can be used to estimate the cumulative incidence of drug-related injury, and to provide insights into its epidemiology. To this end, we develop a modelling framework for under-reporting of retrospective claims for compensation arising from drug damage. The model involves a longitudinal component related to attrition of cases over time, and a cross-sectional component related to incomplete reporting. We apply this model to cardiac valve surgery necessitated by exposure to benfluorex. Benfluorex was marketed in France between 1976 and 2009, when it was withdrawn because it caused valvular heart disease. A scandal erupted in 2010 over the scale of the damage caused by the drug. Since then, no further estimates of cumulative incidence have been published, though thousands of claims for compensation have been processed. The analysis combines compensation claims data and sociological survey data on benfluorex users, together with data on benfluorex sales and duration of treatment. We find a threshold of toxicity at about 6 months' exposure, and that at least 1690 individuals (95% CI 1290 to 2320) needed heart surgery to replace or repair valves damaged by exposure to benfluorex in France: a cumulative incidence of 3.68 per 10,000 (95% CI 2.68 to 5.34) benfluorex users or 3.22 per 10,000 (95% CI 2.48 to 4.39) person-years at risk above the exposure threshold. While these findings are tentative, they are consistent with those obtained previously using very different methods.


Subject(s)
Cardiac Surgical Procedures , Fenfluramine , Humans , Retrospective Studies , Fenfluramine/analogs & derivatives , Fenfluramine/adverse effects , France/epidemiology , Incidence , Female , Male , Cardiac Surgical Procedures/adverse effects , Middle Aged , Adult , Heart Valve Diseases/surgery , Heart Valve Diseases/chemically induced , Heart Valve Diseases/epidemiology , Compensation and Redress , Aged , Models, Statistical , Hypoglycemic Agents/adverse effects , Hypoglycemic Agents/therapeutic use , Insurance Claim Review
5.
Clin Cardiol ; 47(5): e24268, 2024 May.
Article in English | MEDLINE | ID: mdl-38741388

ABSTRACT

BACKGROUND: Observational studies suggest that valvular surgery can reduce mortality in selected patients with infective endocarditis (IE). However, the benefit of this intervention according to frailty levels remains unclear. Our study aims to assess the effect of valvular surgery according to frailty status in this population. METHODS: We performed a retrospective study using the 2016-2019 National Inpatient Sample database. Adult patients with a primary diagnosis of IE were included. Frailty was assessed using the Hospital Frailty Risk Score. Inverse probability of treatment weighting (IPTW) was used to balance baseline differences between groups. RESULTS: A total of 53,275 patients with IE were included, with 18.3% underwent valvular surgery. The median age was 52 (34-68) years, with 41% females. Overall, 42.7% had low risk of frailty, 53.1% intermediate risk, and 4.2% high risk. After IPTW adjustment, in-hospital mortality was similar both for the entire cohort between valvular and non-valvular surgery groups (3.7% vs. 4.1%, p = .483), and low (1% vs. 0.9%, p = .952) or moderate (5.4% vs. 6%, p = .548) risk of frailty. However, patients at high risk of frailty had significantly lower in-hospital mortality in the valvular surgery group (4.6% vs. 13.9%, p = .016). Renal replacement therapy was similar between groups across frailty status. In contrast, surgery was associated with increased use of mechanical circulatory support and pacemaker implantation. CONCLUSIONS: Our findings suggest that there was no difference in survival between valve surgery and medical management in patients at low/intermediate frailty risk, but not for high-risk individuals.


Subject(s)
Endocarditis , Frailty , Hospital Mortality , Humans , Female , Male , Middle Aged , Retrospective Studies , Frailty/complications , Frailty/diagnosis , Aged , Endocarditis/surgery , Endocarditis/mortality , Endocarditis/complications , Risk Factors , Risk Assessment/methods , Adult , United States/epidemiology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Diseases/surgery , Heart Valve Diseases/complications , Survival Rate/trends
7.
PLoS One ; 19(5): e0303163, 2024.
Article in English | MEDLINE | ID: mdl-38713654

ABSTRACT

INTRODUCTION: Cardiovascular diseases (CVD) are a group of illnesses that include coronary heart disease, cerebrovascular disease, congenital heart disease and deep vein thrombosis. Major surgery is often chosen as the treatment of choice for CVD. The concept of fast-track rehabilitation after surgery appeared in the 1970s. Participation in these exercise-based prehabilitation programmes may decrease postoperative complications and length of hospital stay. The primary aim of the present study is to evaluate whether the implementation of an additional resistance training (RT) prehabilitation protocol within cardiac exercises based prehabilitation can reduce intensive care unit (ICU) length of stay, postoperative complications and hospital length of stay (LOS). METHODS: A protocol of a prospective, parallel, randomised clinical trial includes 96 adult patients diagnosed with valvular pathology and who have been scheduled for surgery. The participants will be randomly assigned to two groups of 48. Control group will be treated with ventilatory and strengthening of respiratory muscles, and aerobic exercise. Experimental group, in addition, will be treated with RT of peripheral muscles. Both hospital stay and ICU stay will be assessed as main variables. Other secondary variables such as exercise capacity, quality of life and respiratory values will also be assessed. Quantitative variables will be analysed with a T-Test or ANOVA, or Mann Witney if the distribution is non-parametric. RESULTS AND CONCLUSION: This will be the first controlled clinical study focused on adding strength exercise as an additional treatment during prehabilitation. The results of this study will focus on helping to improve rehabilitation and prehabilitation protocols, considering that it is essential to maintain pulmonary training, as well as the inclusion of peripheral exercises that help people with heart disease to be in a better physical condition in order to increase their participation and sense of quality of life.


Subject(s)
Cardiac Surgical Procedures , Preoperative Exercise , Resistance Training , Adult , Female , Humans , Male , Middle Aged , Cardiac Surgical Procedures/rehabilitation , Heart Valve Diseases/surgery , Heart Valve Diseases/rehabilitation , Heart Valves/surgery , Length of Stay , Postoperative Complications/prevention & control , Postoperative Complications/rehabilitation , Prospective Studies , Quality of Life , Resistance Training/methods , Randomized Controlled Trials as Topic
8.
J Cardiothorac Surg ; 19(1): 290, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38750504

ABSTRACT

OBJECTIVES: This study aimed to identify the risk factors for postoperative atrial fibrillation in patients with valvular atrial fibrillation, and establish predictive models of atrial fibrillation recurrence. METHODS: Overall, 224 patients who underwent radiofrequency ablation of atrial fibrillation from November 2014 to November 2020 were included. The statistical package for social sciences, X-tile, and R-studio were used for statistical analysis. RESULTS: Patients were divided into training and validation sets according to a ratio of 3:1. The training set was analysed using univariate and multivariate Cox regression analysis and showed that preoperative uric acid > 401 µmol/L (P = 0.006), B-type natriuretic peptide > 202 ng/L (P = 0.042), hypersensitivity C-reactive protein > 6.1 mg/L (P = 0.026), erythrocyte sedimentation rate > 7.0 mm/h (P = 0.016), preoperative left atrial diameter > 48 mm (P = 0.031) were significantly correlated with the recurrence of atrial fibrillation after radiofrequency ablation in patients with valvular atrial fibrillation. In the training set, a Cox regression model of the five related factors was established using the R language. The C-index of the model was 0.82, and the area under the receiver operating characteristic curve was 0.831 (P < 0.001). Internal and external verification was performed in the training and validation sets, respectively, and both showed that the fit of the verification curve was relatively good at 3 months, 6 months, 1 year, and 3 years postoperatively. After calculating the weight of each related factor using the nomogram, a new risk predictive model (BLUCE) for postoperative atrial fibrillation was established. CONCLUSIONS: In patients with atrial fibrillation, preoperative uric acid, B-type natriuretic peptide, hypersensitivity C-reactive protein, erythrocyte sedimentation rate, and left atrial diameter are risk factors for atrial fibrillation or atrial flutter recurrence after radiofrequency ablation. The BLUCE predictive model can distinguish high-risk groups of postoperative atrial fibrillation. High-risk patients in the BLUCE model were more likely to experience recurrence of atrial fibrillation after radiofrequency ablation and a low possibility of maintaining sinus rhythm.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Valve Diseases , Mitral Valve , Recurrence , Humans , Atrial Fibrillation/surgery , Male , Female , Middle Aged , Heart Valve Diseases/surgery , Mitral Valve/surgery , Catheter Ablation/methods , Risk Factors , Retrospective Studies , Aged , Radiofrequency Ablation/methods , Risk Assessment/methods
9.
Clin Interv Aging ; 19: 695-703, 2024.
Article in English | MEDLINE | ID: mdl-38711477

ABSTRACT

Purpose: In mixed aortic valve disease (MAVD), the results of transcatheter aortic valve replacement (TAVR) are conflicting. There is limited data on the outcomes of TAVR in patients with bicuspid aortic valve (BAV) and MAVD. The objective of this study is to compare outcomes after TAVR in BAV patients with MAVD and predominant aortic stenosis (PAS). Patients and Methods: Patients with BAV who underwent TAVR between January 2016 and April 2023 were included. The primary outcome was device success. The secondary endpoints were periprocedural mortality and other complications as defined by the Valve Academic Research Consortium-3 (VARC-3). Propensity score matching was used to minimize potential confounding. Results: A total of 262 patients were included in this study, 83 of whom had MAVD. The median age was 72 years, and 55.7% were male. The baseline comorbidity risk files were comparable between the two groups. Patients with MAVD had more mitral regurgitation, tricuspid regurgitation and pulmonary hypertension, larger annular and left ventricular outflow tract dimensions, and more severe calcification than PAS. In the unmatched population, MAVD patients had similar device success rate (69.9% vs 79.9%, P=0.075) and 30-day mortality (3.6% vs 3.4%, P=1) compared to PAS. Propensity score matching resulted in 66 patient pairs. Device success rate were still comparable in the matched population. Other clinical outcomes, including stroke, bleeding (type 2-4), major vascular complications, acute kidney injury (stage 2-4) and permanent pacemaker implantation, were comparable between the two groups. Multivariable logistic regression analysis did not show MAVD to be an independent negative predictor of device success. At one year, survival was similar between patients with MAVD and those with PAS. Conclusion: For the bicuspid valve, patients with MAVD had a more challenging anatomy. MAVD patients associated with comparable 30-day clinical outcomes after TAVR compared to PAS patients in patients with BAV.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Postoperative Complications , Propensity Score , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Aortic Valve Stenosis/surgery , Aged , Bicuspid Aortic Valve Disease/surgery , Aged, 80 and over , Postoperative Complications/epidemiology , Retrospective Studies , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/abnormalities , Middle Aged , Risk Factors , Heart Valve Diseases/surgery
10.
J Cardiothorac Surg ; 19(1): 191, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38589959

ABSTRACT

BACKGROUND: Fungal endocarditis is a rare but serious condition associated with high mortality rates. Various predisposing factors contribute to its occurrence, such as underlying cardiac abnormalities, cardiac surgeries, prosthetic cardiac devices, and central venous catheters. Diagnosing fungal endocarditis, particularly Aspergillus, poses challenges, often complicated by negative blood cultures. CASE PRESENTATION: This report details a case of extensive ascending aorta involvement in Aspergillus endocarditis (AE) in a 24-year-old man with a history of bioprosthesis aortic valve replacement (AVR). Three months post-AVR, he presented with pericardial effusion and aortic rupture, leading to a redo biological valved conduit aortic root replacement (Bentall surgery). Despite the intervention, the tubular graft exhibited extensive Aspergillus involvement, resulting in graft disruption and significant peri-aortic infection. A second redo procedure involving aortic homograft root replacement was performed. Unfortunately, the patient succumbed two days after the surgery. CONCLUSION: A combined approach of medical and surgical therapies is recommended to manage fungal endocarditis. Despite efforts, the mortality rate associated with Aspergillus endocarditis remains unacceptably high, with no significant difference observed between combination therapy and antifungal treatment alone. Further research is essential to explore novel therapeutic strategies and improve outcomes for patients with this challenging condition.


Subject(s)
Bioprosthesis , Endocarditis , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mycoses , Humans , Male , Young Adult , Aorta/surgery , Aorta, Thoracic/surgery , Aortic Valve/surgery , Bioprosthesis/adverse effects , Endocarditis/diagnosis , Endocarditis/surgery , Heart Valve Diseases/surgery , Heart Valve Prosthesis/adverse effects
12.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38608189

ABSTRACT

OBJECTIVES: Repair of the bicuspid aortic valve (BAV) has evolved in the past 25 years. The aim of this study was to review and analyse the long-term durability of isolated BAV repair with particular focus on commissural orientation (CO). METHODS: All patients who underwent BAV repair for severe aortic regurgitation between October 1998 and December 2022 were included. The study group consists of all patients operated after 2009, i.e. since CO modification. The control group includes patients who were operated before 2009. CO was classified as symmetric, asymmetric and very asymmetric. RESULTS: Overall, 594 adult patients (93% male; mean age 42 years) were included. At 15 years, survival was 94.8% [standard deviation (SD): 2.2]; freedom from reoperation was 86.8% (SD: 2.3). Freedom from aortic insufficiency ≥II was 70.8% (SD: 4.7) at 15 years. Modification of CO by sinus plication was performed in 200 (33.7%) instances. Using competing risks analysis, the absence of effective height measurement (P = 0.018), very asymmetric CO (P = 0.028), the presence of calcification (P < 0.001), the use of pericardial patch (P < 0.001), the use of subcommissural sutures (P < 0.001) and preoperative endocarditis (P = 0.005) were identified as independent predictors for reoperation. Follow-up was 97% complete (4228 patient-years); mean follow-up was 7 years (SD: 5). CONCLUSIONS: Isolated BAV repair leads to good survival and durability in all morphologic types if cusp repair is guided by effective height, suture annuloplasty is performed, and CO is modified using sinus plication in asymmetrical valves. Very asymmetrical valves may should be treated with a lower threshold for replacement.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Bicuspid Aortic Valve Disease , Humans , Male , Bicuspid Aortic Valve Disease/surgery , Aortic Valve/surgery , Aortic Valve/abnormalities , Adult , Female , Aortic Valve Insufficiency/surgery , Middle Aged , Retrospective Studies , Treatment Outcome , Reoperation/statistics & numerical data , Heart Valve Diseases/surgery , Young Adult , Follow-Up Studies
14.
Inn Med (Heidelb) ; 65(5): 439-446, 2024 May.
Article in German | MEDLINE | ID: mdl-38597993

ABSTRACT

There is a broad spectrum of mitral valve diseases ranging from young patients with rheumatic mitral valve stenosis up to older patients with secondary mitral valve regurgitation and numerous comorbidities. A profound understanding of the etiology, anatomical characteristics of mitral valve diseases and current treatment options is necessary to be able to prepare a patient-centered treatment approach. The interdisciplinary collaboration of referring physicians, interventional cardiologists, cardiac surgeons, heart failure and imaging specialists as well as anesthesiologists is a cornerstone of optimal patient treatment.


Subject(s)
Cardiac Catheterization , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Cardiac Catheterization/methods , Mitral Valve/surgery , Mitral Valve/pathology , Mitral Valve/diagnostic imaging , Mitral Valve Stenosis/surgery , Mitral Valve Stenosis/diagnostic imaging , Heart Valve Diseases/surgery , Heart Valve Diseases/diagnostic imaging , Heart Valve Prosthesis Implantation/methods
15.
Comput Methods Programs Biomed ; 250: 108173, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38615386

ABSTRACT

BACKGROUND AND OBJECTIVE: The conventional valve stents that are cylindrical in shape will become elliptical when implanted in bicuspid aortic valve, thereby reducing the durability of the artificial valve. In this study, a new design of valve stent is presented where valve stents have elliptical cross-section at the annulus and it is expected to have better expandability and circle shape during the interaction between the stent and bicuspid aortic valve, thereby extending the durability of artificial valve. METHODS: Finite element method (FEM) is used to study the mechanical behavior of the novel valve stent in the bicuspid aortic valve. The effects of three matching relationship between the ellipticity of the stents and the ellipticity of the annulus (i.e., the ellipticity of the stent is greater than, equal to and less than the annulus ellipticity, respectively) on the mechanical behavior of stent expansion are studied. In addition, the expansion mechanical behavior of the novel valve stent at different implantation depths is also compared. RESULTS: Results indicate that novel valve stent implantation with elliptical features is superior to conventional circular valve stent. When the novel valve stent ellipticity is less than the annulus ellipticity, the ellipticity of the novel valve stent after implantation is smaller than that of the conventional circular valve stent. This indicated that the novel valve stent has better expandability and post-expansion shape, making artificial valve to have better durability. The risk of paravalvular leak after implantation is lowest when the novel valve stent ellipticity is less than annulus ellipticity. When the novel valve stent ellipticity coincides with annulus ellipticity, the aortic wall is subjected to greatest stress. With the increase of implantation depth, the stress on the novel valve stent decrease. CONCLUSIONS: This study might provide insights for improving stent design for bicuspid aortic valve.


Subject(s)
Aortic Valve , Bicuspid Aortic Valve Disease , Finite Element Analysis , Heart Valve Prosthesis , Prosthesis Design , Stents , Aortic Valve/abnormalities , Aortic Valve/surgery , Humans , Bicuspid Aortic Valve Disease/surgery , Stress, Mechanical , Heart Valve Diseases/surgery , Aortic Valve Disease/surgery
16.
Int J Cardiol ; 407: 132000, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38561108

ABSTRACT

AIM: To evaluate the association between raphe in bicuspid aortic valve (BAV) patients and valve dysfunction, aortopathy and aortic valve surgery in the REBECCA registry [REgistro della valvola aortica Bicuspide della Società Italiana di ECocardiografia e CArdiovascular Imaging (SIECVI)]. METHODS: Prevalence of aortic valve dysfunction and aortopathy was investigated in BAV patients with and without raphe. Aortic valve dysfunction (regurgitation or stenosis) was categorized as mild, moderate and severe. Aortopathy was defined as annulus ≥14 mm/m2; root ≥20 mm/m2; sinotubular junction ≥16 mm/m2; ascending aorta ≥17 mm/m2, and classified in Type A, isolated ascending aorta dilatation; Type B, aortic root and ascending aorta dilatation; and Type C, isolated aortic root dilatation. RESULTS: Overall, 695 patients with BAV were enrolled; 520 (74.8%) with raphe and 175 (25.2%) without raphe. BAV patients with raphe presented more frequently with moderate or severe aortic stenosis than BAV patients without raphe (183 [35.2%] vs 34 [19.4%], p < 0.001). A higher prevalence of aortopathy, particularly Type B, was observed in patients with vs without raphe. At multivariable analysis, raphe was a predictor of aortic valve surgery at three-year follow-up (odds ratio 2.19, 95% confidence interval 1.08-4.44, p < 0.001). CONCLUSIONS: Patients with BAV and raphe have a higher prevalence of significant aortic stenosis, aortopathy, especially Type B, and a higher risk of undergoing aortic valve surgery at three-year follow-up.


Subject(s)
Aortic Valve , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Registries , Humans , Male , Female , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/complications , Middle Aged , Aortic Valve/abnormalities , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aged , Heart Valve Diseases/surgery , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/complications , Aortic Diseases/surgery , Aortic Diseases/diagnostic imaging , Aortic Diseases/epidemiology , Adult , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Follow-Up Studies , Italy/epidemiology
18.
Am J Cardiol ; 221: 64-73, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38636624

ABSTRACT

Bioprosthetic mitral valve replacement (bMVR) use is increasing; however, data regarding long-term durability are lacking. We sought to perform a reconstructed individual patient data meta-analysis from published Kaplan-Meier curves to ascertain survival, freedom from valve degeneration, and reoperation in studies published since 2010. We explored the effects of age and valve type (bovine pericardial or porcine valve) on outcomes. We searched MEDLINE, OVID, Embase, and Cochrane CENTRAL for studies reporting at least 3 years of follow-up after bMVR and published since 2010. The Risk Of Bias In Non-randomised Studies of Interventions (ROBINS-I) tool was used to assess methodologic quality. Kaplan-Meier curves were digitized to extract individual patient data and reconstructed estimates for overall survival, freedom from structural valve deterioration (SVD), and freedom from reoperation. A total of 20 studies (16,465 patients) were included. A total of 9 studies reported on porcine valves, 6 reported on bovine, and 7 did not specify the valve type. The overall survival after bMVR at 15 years was 40% (confidence interval 38% to 42%), freedom from reoperation at 15 years was 79% (confidence interval 76% to 82%), and freedom from SVD at 15 years was 64% (58% to 70%). Freedom from SVD was improved in the 70+ years age group (93% up to 25 years, hazard ratio 6.6 [2.5 to 17] for 18 to 59 vs >70 years, p <0.0001). There was no difference in valve durability or survival between bovine pericardial or porcine valves. In this meta-analysis of patients who underwent bMVR using newer generation valves, the inverse relation between age and SVD was reiterated in the 70+ years age group. The prosthesis type made no difference in the outcomes.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis , Mitral Valve , Humans , Mitral Valve/surgery , Reoperation/statistics & numerical data , Heart Valve Prosthesis Implantation/methods , Prosthesis Failure , Heart Valve Diseases/surgery , Animals , Prosthesis Design , Time Factors , Treatment Outcome
19.
Curr Opin Cardiol ; 39(4): 380-387, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38606679

ABSTRACT

PURPOSE OF REVIEW: Patients with advanced age and frailty require interventions for structural heart disease at an increasing rate. These patients typically experience higher rates of postoperative morbidity, mortality and prolonged hospital length of stay, loss of independence as well as associated increased costs to the healthcare system. Therefore, it is becoming critically important to raise awareness and develop strategies to improve clinical outcomes in the contemporary, high-risk patient population undergoing cardiacprocedures. RECENT FINDINGS: Percutaneous options for structural heart disease have dramatically improved the therapeutic options for some older, frail, high-risk patients; however, others may still require cardiac surgery. Minimally invasive techniques can reduce some of the physiologic burden experienced by patients undergoing surgery and improve recovery. Enhanced Recovery After Cardiac Surgery (ERAS Cardiac) is a comprehensive, interdisciplinary, evidence-based approach to perioperative care. It has been shown to improve recovery and patient satisfaction while reducing complications and length of stay. SUMMARY: Combining minimally invasive cardiac surgery with enhanced recovery protocols may result in improved patient outcomes for a patient population at high risk of morbidity and mortality following cardiac surgery.


Subject(s)
Enhanced Recovery After Surgery , Minimally Invasive Surgical Procedures , Humans , Minimally Invasive Surgical Procedures/methods , Cardiac Surgical Procedures/methods , Heart Valve Diseases/surgery , Postoperative Complications/prevention & control , Perioperative Care/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...