Sci Rep ; 14(1): 10409, 2024 05 06.
Article in English | MEDLINE | ID: mdl-38710782

ABSTRACT

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Transcatheter Aortic Valve Replacement , Transcatheter Aortic Valve Replacement/methods , Humans , Male , Female , Aged, 80 and over , Aged , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/surgery , Tomography, X-Ray Computed , Aorta/diagnostic imaging , Aorta/surgery , Treatment Outcome , Heart Valve Prosthesis , Retrospective Studies
2.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38710669

ABSTRACT

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Subject(s)
Aortic Valve , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hemodynamics , Humans , Hemodynamics/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aged , Female , Male , Aged, 80 and over , Heart Valve Prosthesis Implantation/methods , Echocardiography , Middle Aged , Prosthesis Design
3.
Trials ; 25(1): 324, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755709

ABSTRACT

BACKGROUND: The optimal antithrombotic strategy early after aortic valve replacement surgery with a biological valve remains controversial due to lack of high-quality evidence. Either oral anticoagulants or acetylsalicylic acid should be considered for the first 3 months. Hypo-attenuated leaflet thickening on cardiac computed tomography has been associated with latent bioprosthetic valve thrombosis and may be prevented with anticoagulation. We hypothesize that anticoagulation with apixaban is superior to single antiplatelet therapy with acetylsalicylic acid in reducing hypo-attenuated leaflet thickening of bioprosthetic aortic valve prostheses. METHODS: In this prospective, open-label, randomized trial, patients undergoing isolated aortic valve replacement surgery with rapid deployment bioprosthetic valves will be randomized. The treatment group will receive 5 mg of apixaban twice a day for the first 3 months and 100 mg of acetylsalicylic acid thereafter. The control group will be administered 100 mg of acetylsalicylic acid once a day, indefinitely. After the 3-month treatment period, a contrast-enhanced electrocardiogram-gated cardiac computed tomography will be performed to identify hypo-attenuated leaflet thickening of the bioprosthetic valve. The primary objective of the study is to assess the impact of apixaban on the prevention of hypo-attenuated leaflet thickening at 3 months. The secondary and exploratory endpoints will be clinical outcomes and safety profiles of the two strategies. DISCUSSION: Antithrombotic therapy after aortic valve replacement is used to prevent valve thrombosis and systemic thromboembolism. Latent bioprosthetic valve thrombosis is a precursor of clinically significant prosthetic valve dysfunction or thromboembolic events. The hallmark feature of latent bioprosthetic valve thrombosis is hypo-attenuated leaflet thickening on cardiac computed tomography. Subclinical leaflet thrombosis occurs frequently in bioprosthetic aortic valves, more commonly in transcatheter than in surgical valves. There is no evidence on the effect of direct oral anticoagulants on the incidence of hypo-attenuated leaflet thickening after surgical aortic valve replacement with rapid deployment bioprostheses. TRIAL REGISTRATION: ClinicalTrials.gov NCT06184113. Registered on December 28, 2023.


Subject(s)
Aortic Valve , Aspirin , Bioprosthesis , Factor Xa Inhibitors , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pyrazoles , Pyridones , Randomized Controlled Trials as Topic , Thrombosis , Humans , Aspirin/administration & dosage , Aspirin/therapeutic use , Aspirin/adverse effects , Pyridones/therapeutic use , Pyridones/administration & dosage , Pyridones/adverse effects , Prospective Studies , Heart Valve Prosthesis/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Thrombosis/prevention & control , Thrombosis/etiology , Pyrazoles/therapeutic use , Pyrazoles/administration & dosage , Pyrazoles/adverse effects , Factor Xa Inhibitors/administration & dosage , Factor Xa Inhibitors/adverse effects , Factor Xa Inhibitors/therapeutic use , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Platelet Aggregation Inhibitors/administration & dosage , Platelet Aggregation Inhibitors/therapeutic use , Platelet Aggregation Inhibitors/adverse effects , Female , Male , Middle Aged , Time Factors , Aged , Adult , Fibrinolytic Agents/administration & dosage , Fibrinolytic Agents/adverse effects
4.
Braz J Cardiovasc Surg ; 39(4): e20230237, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748975

ABSTRACT

Transcatheter mitral valve-in-valve is an alternative to high-risk reoperation on a failing bioprosthesis. It entails specific challenges such as left ventricular outflow tract obstruction. We propose a patient-specific augmented imaging based on preoperative planning to assist the procedure. Valve-in-valve simulation was performed to represent the optimal level of implantation and the neo-left ventricular outflow tract. These data were combined with intraoperative images through a real-time 3D/2D registration tool. All data were collected retrospectively on one case (pre and per-procedure imaging). We present for the first time an intraoperative guidance tool in transcatheter mitral valve-in-valve procedure.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve , Surgery, Computer-Assisted , Humans , Heart Valve Prosthesis Implantation/methods , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Surgery, Computer-Assisted/methods , Cardiac Catheterization/methods , Bioprosthesis , Retrospective Studies , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Female , Male
5.
Echocardiography ; 41(5): e15835, 2024 May.
Article in English | MEDLINE | ID: mdl-38784978

ABSTRACT

PURPOSE: There is currently limited information on the utility of transthoracic echocardiography (TTE)-derived Doppler parameters for assessing bioprosthetic tricuspid valve (BTV) dysfunction. Our study aimed to establish the precision and appropriate reference ranges for routinely collected transthoracic Doppler parameters in the assessment of BTV dysfunction. METHODS: We retrospectively evaluated 100 BTV patients who underwent TTE. Based on redo surgical confirmation or more than 2 repeat TTE or transesophageal echocardiography (TEE) examinations, patients were allocated to normal (n = 61), regurgitant (n = 24), or stenotic (n = 15) BTV group. Univariate and multivariate binary logistic regression were performed to identify TTE Doppler parameters that detected BTV dysfunction. RESULTS: The VTI ratio (VTITV/VTILVOT) was the most accurate Doppler parameter for detecting BTV dysfunction, with a ratio of >2.8 showing 84.6% sensitivity and 90.2% specificity. VTI ratio > 3.2, mean gradient (MGTV) > 6.2 mmHg and pressure half-time > 218 ms detected significant BTV stenosis, with sensitivities of 100%, 93.3% and 93.3% and specificities of 82.4%, 75.3% and 87.1%, respectively. After multivariate analysis, the VTI ratio > 2.8 (OR = 9.00, 95% CI = 2.13-41.61, p = .003) and MGTV > 5.1 mmHg (OR = 6.50, 95% CI = 1.69-27.78, p = .008) were the independent associations of BTV dysfunction. With these cutoff values, 75.0%-92.2% of normal and 62.5%-96.0% of dysfunctional BTV were identified. CONCLUSIONS: Doppler parameters from TTE can accurately identify BTV dysfunction, particularly with VTI ratio > 2.8 and MGTV > 5.1 mmHg, to assess the need for additional testing with TEE.


Subject(s)
Bioprosthesis , Echocardiography, Doppler , Heart Valve Prosthesis , Sensitivity and Specificity , Tricuspid Valve , Humans , Female , Male , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Middle Aged , Echocardiography, Doppler/methods , Retrospective Studies , Reproducibility of Results , Aged , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/diagnostic imaging
6.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38742523

ABSTRACT

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Registries , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Male , Female , Aged , Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Italy/epidemiology , Aged, 80 and over , Patient Readmission/statistics & numerical data , Treatment Failure , Heart Valve Prosthesis , Mitral Valve Annuloplasty/instrumentation , Mitral Valve Annuloplasty/adverse effects , Treatment Outcome , Time Factors , Risk Factors , Heart Failure/mortality , Heart Failure/physiopathology , Heart Failure/surgery
7.
J Am Heart Assoc ; 13(10): e032094, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38761076

ABSTRACT

BACKGROUND: Anticoagulation in patients with intracranial hemorrhage (ICH) and mechanical heart valves is often held for risk of ICH expansion; however, there exists a competing risk of acute ischemic stroke (AIS). Optimal timing to resume anticoagulation remains uncertain. METHODS AND RESULTS: We retrospectively studied patients with ICH and mechanical heart valves from 2000 to 2018. The primary outcome was a composite end point of symptomatic hematoma expansion or new ICH, AIS, and intracardiac thrombus up to 30 days post-ICH. The exposure was timing of reinitiation of anticoagulation classified as early (resumed up to 7 days after ICH), late (≥7 and up to 30 days after ICH), and never if not resumed or resumed after 30 days post-ICH. We included 184 patients with ICH and mechanical heart valves (65 anticoagulated early, 100 late, 19 not resumed by day 30 post-ICH). Twelve patients had AIS, 16 new ICH, and 6 intracardiac thromboses. The mean time from ICH to anticoagulation was 12.7 days. Composite outcomes occurred in 12 patients resumed early (18.5%), 14 resumed late (14.0%), and 4 never resumed (21.1%). There was no increased hazard of the composite outcome (hazard ratio [HR], 1.1 [95% CI, 0.2-6.0]), AIS, or worsening or new ICH among patients resumed early versus late. There was no difference in the composite among patients never resumed versus resumed. Patients who never resumed anticoagulation had significantly more severe ICH (median Glasgow Coma Scale: 10.6, 13.9, and 13.9 among those who resumed never, early, and late, respectively; P=0.0001), higher in-hospital mortality (56.5%, 0%, and 0%, respectively; P<0.0001), and an elevated 30-day AIS risk (HR, 15.9 [95% CI, 1.9-129.7], P=0.0098). CONCLUSIONS: In this study of patients with ICH and mechanical heart valves, there was no difference in 30-day thrombotic and hemorrhagic brain-related outcomes when anticoagulation was resumed within 7 versus 7 to 30 days after ICH. Withholding anticoagulation >30 days was associated with severe baseline ICH, higher in-hospital case fatality, and elevated AIS risk.


Subject(s)
Anticoagulants , Heart Valve Prosthesis , Intracranial Hemorrhages , Humans , Male , Anticoagulants/administration & dosage , Anticoagulants/adverse effects , Female , Retrospective Studies , Aged , Intracranial Hemorrhages/chemically induced , Intracranial Hemorrhages/epidemiology , Time Factors , Heart Valve Prosthesis/adverse effects , Middle Aged , Ischemic Stroke/diagnosis , Ischemic Stroke/mortality , Aged, 80 and over , Risk Factors , Drug Administration Schedule , Treatment Outcome , Risk Assessment
8.
Curr Probl Cardiol ; 49(7): 102628, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38729276

ABSTRACT

Mechanical prosthetic valve thrombosis (MPVT) is a common complication of valvular implantations. This study compared the efficacy and safety of different treatments for MPVT. A systematic search of electronic databases identified studies evaluating surgical, anticoagulant, and thrombolytic therapies. Although several studies of different types have been conducted to evaluate the efficacy of these treatment strategies the lack of randomized controlled trials has resulted in the inability to make a definitive conclusion about the pros and cons of these treatments. Recent treatments, such as slow and ultraslow infusion of thrombolytics, showed comparable efficacy and lower complication rates than traditional methods. Inadequate anticoagulant use is a major risk factor for MPVT, highlighting the importance of prevention. Treatment selection should be individualized based on patient factors and available expertise. Overall, slow and ultraslow infusion of thrombolytics may be a promising treatment option for MPVT.


Subject(s)
Anticoagulants , Fibrinolytic Agents , Heart Valve Prosthesis , Thrombolytic Therapy , Thrombosis , Humans , Heart Valve Prosthesis/adverse effects , Thrombosis/etiology , Thrombosis/prevention & control , Thrombolytic Therapy/methods , Thrombolytic Therapy/adverse effects , Fibrinolytic Agents/therapeutic use , Anticoagulants/therapeutic use , Risk Factors , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Treatment Outcome
9.
Kyobu Geka ; 77(5): 361-363, 2024 May.
Article in Japanese | MEDLINE | ID: mdl-38720605

ABSTRACT

Prosthetic valve endocarditis (PVE) is rare but devastating. A 69-year old man admitted for active endocarditis caused by Streptococcus pasteurianus. Antibiotic therapy was started, but the patient developed bowel obstruction owing to cancer with multiple liver metastases, and underwent transverse colectomy. Following colectomy, antibiotic agent was given continued for 4 weeks after and mitral valve replacement( MVR) using a bioprosthesis was performed. Oral antibiotic therapy was continued for six months after MVR to avoid infection recurrence. One year after MVR, the size of multiple liver metastases increased despite oral anticancer drugs administration. A totally implantable central venous access port( CV port) was placed and intravenous chemotherapy was started for progressive metastatic colorectal cancer. But the CV port was removed due to device infection caused by multiple drug resistant Staphyrococcus lugdunensis one month later, but the patient developed prosthetic valve endocarditits( PVE) due to the same bacterium, that caused valve stenosis. Redo MVR was indicated because of progressive dyspnea and uncontrollable fever. The patient was discharged one month after redo MVR, but suffered carcinomatous peritonitis, and eventually died eight months post-discharge. Chemotherapy needs caution because of potential risk of PVE in patients with prosthetic valves, especially for those with a history of infectious endocarditis.


Subject(s)
Colonic Neoplasms , Heart Valve Prosthesis , Mitral Valve , Humans , Male , Aged , Mitral Valve/surgery , Colonic Neoplasms/surgery , Colonic Neoplasms/complications , Heart Valve Prosthesis/adverse effects , Fatal Outcome , Reoperation , Prosthesis-Related Infections/surgery , Prosthesis-Related Infections/etiology , Heart Valve Prosthesis Implantation , Endocarditis, Bacterial/surgery
10.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726714

ABSTRACT

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Female , Male , Aged, 80 and over , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Prosthesis Design , Hemodynamics , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Hospital Mortality
11.
J Cardiothorac Surg ; 19(1): 292, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38760659

ABSTRACT

BACKGROUND: Although well-known for their thromboresistance, bileaflet mechanical heart valves (BMHV) require lifelong anti-thrombotic therapy. This must be associated with a certain level of thrombogenicity. Since both thromboresistance and thrombogenicity are explained by the blood-artificial surface or liquid-solid interactions, the aim of the present study was to explore BMHV thromboresistance from new perspectives. The wettability of BMHV pyrolytic carbon (PyC) occluders was investigated in under-liquid conditions. The submerged BMHV wettability clarifies the mechanisms involved in the thromboresistance. METHODS: The PyC occluders of a SJM Regent™ BMHV were previously laser irradiated, to create a surface hierarchical nano-texture, featuring three nano-configurations. Additionally, four PyC occluders of standard BMHV (Carbomedics, SJM Regent™, Bicarbon™, On-X®), were investigated. All occluders were evaluated in under-liquid configuration, with silicon oil used as the working droplet, while water, simulating blood, was used as the surrounding liquid. The under-liquid droplet-substrate wetting interactions were analyzed using contact angle goniometry. RESULTS: All the standard occluders showed very low contact angle, reflecting a pronounced affinity for non-polar molecules. No receding of the contact line could be observed for the untreated occluders. The smallest static contact angle of around 61° could be observed for On-X® valve (the only valve made of full PyC). The laser-treated occluders strongly repelled oil in underwater conditions. A drastic change in their wetting behaviour was observed depending on the surrounding fluid, displaying a hydrophobic behaviour in the presence of air (as the surrounding medium), and showing instead a hydrophilic nature, when surrounded by water. CONCLUSIONS: BMHV "fear" water and blood. The intrinsic affinity of BMHV for nonpolar fluids can be translated into a tendency to repel polar fluids, such as water and blood. The blood-artificial surface interaction in BMHV is minimized. The contact between blood and BMHV surface is drastically reduced by polar-nonpolar Van der Waals forces. The "hydro/bloodphobia" of BMHV is intrinsically related to their chemical composition and their surface energy, thus their material: PyC indeed. Pertaining to thromboresistance, the surface roughness does not play a significant role. Instead, the thromboresistance of BMHV lies in molecular interactions. BMHV wettability can be tuned by altering the surface interface, by means of nanotechnology.


Subject(s)
Heart Valve Prosthesis , Thrombosis , Wettability , Humans , Thrombosis/prevention & control , Prosthesis Design , Materials Testing
12.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38730543

ABSTRACT

OBJECTIVES: The aim of this study was to describe trends and outcomes for patients undergoing surgical aortic valve replacement (SAVR) in the Netherlands. METHODS: The Netherlands Heart Registration database was used to report the number and outcomes of isolated, primary SAVR procedures performed from 2007 to 2018 in adult patients. RESULTS: A total of 17 142 procedures were included, of which 77.9% were performed using a biological prosthesis and 21.0% with a mechanical prosthesis. Median logistic EuroSCORE I decreased from 4.6 [interquartile range (IQR) 2.4-7.7] to 4.0 (IQR 2.6-6.0). The 120-day mortality decreased from 3.3% in 2007 to 0.7% in 2018. The median duration of follow-up was 76 months (IQR 53-111). Ten-year survival, when adjusted for age, EuroSCORE I and body surface area, was 72.4%, and adjusted 10-year freedom from reinvervention was 98.1%. Additional analysis for patients under the age of 60 showed no difference between patients treated with a biological or mechanical prosthesis in adjusted 10-year survival, 89.7% vs 91.9±%, respectively (P = 0.25), but a significant difference in adjusted 10-year freedom from reintervention, 90.0±% vs 95.9%, respectively (P < 0.01). CONCLUSIONS: Between 2007 and 2018, age and risk profile of patients undergoing SAVR decreased, especially for patients treated with a biological prosthesis. The 120-day mortality decreased over time. Patients undergoing SAVR nowadays have a risk of 120-day mortality of <1% and 10-year freedom from valve-related reintervention of >95%.


Subject(s)
Aortic Valve , Heart Valve Prosthesis Implantation , Humans , Male , Netherlands/epidemiology , Female , Aged , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/trends , Heart Valve Prosthesis Implantation/statistics & numerical data , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/methods , Middle Aged , Treatment Outcome , Heart Valve Prosthesis/trends , Aged, 80 and over , Registries , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Risk Factors
13.
Port J Card Thorac Vasc Surg ; 31(1): 12-16, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38743522

ABSTRACT

There has been a worldwide rapid adoption of transcatheter aortic valve replacement (TAVR) as an alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis. Currently, more TAVR explants with SAVRs are performed than TAVR-in TAV. TAVR explantation is a technically hazardous procedure mainly due to significant aortic neo-endothelialization which incorporates the TAVR valve. Surgical techniques for TAVR explantation are not well established and surgeon experience at present is limited. In this manuscript, we describe our technique for surgical explantation of transcatheter aortic bioprosthesis. Familiarity with the procedure and its clinical implications is essential for all cardiac surgeons.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Device Removal , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Aortic Valve/pathology , Aortic Valve Stenosis/surgery , Bioprosthesis/adverse effects , Device Removal/methods , Heart Valve Prosthesis/adverse effects , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation
15.
Comput Biol Med ; 176: 108526, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749328

ABSTRACT

Aortic valve replacement has become an increasing concern due to the rising prevalence of aortic stenosis in an ageing population. Existing replacement options have limitations, necessitating the development of improved prosthetic aortic valves. In this study, flow characteristics during systole in a stenotic aortic valve case are compared with those downstream of two newly designed surgical bioprosthetic aortic valves (BioAVs). To do so, advanced three-dimensional fluid-structure interaction simulations are conducted and dedicated analysis methods to investigate jet flow configuration and vortex dynamics are developed. Our findings reveal that the stenotic case maintains a high jet flow eccentricity due to a fixed orifice geometry, resulting in flow separation and increased vortex stretching and tilting in the commissural low-flow regions. One BioAV design introduces non-axisymmetric leaflet motion, which reduces the maximum jet velocity and forms more vortical structures. The other BioAV design produces a fixed symmetric triangular jet shape due to non-moving leaflets and exhibits favourable vorticity attenuation, revealed by negative temporally and spatially averaged projected vortex stretching values, and significantly reduced drag. Therefore, this study highlights the benefits of custom-designed aortic valves in the context of their replacement through comprehensive and novel flow analyses. The results emphasise the importance of analysing jet flow, vortical structures, momentum balance and vorticity transport for thoroughly evaluating aortic valve performance.


Subject(s)
Aortic Valve , Heart Valve Prosthesis , Hemodynamics , Models, Cardiovascular , Humans , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve/physiology , Hemodynamics/physiology , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Blood Flow Velocity , Bioprosthesis
16.
Comput Biol Med ; 176: 108552, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38754219

ABSTRACT

Severe aortic valve stenosis can lead to heart failure and aortic valve replacement (AVR) is the primary treatment. However, increasing prevalence of aortic stenosis cases reveal limitations in current replacement options, necessitating improved prosthetic aortic valves. We investigate flow disturbances downstream of severe aortic stenosis and two bioprosthetic aortic valve (BioAV) designs using advanced energy-based analyses. Three-dimensional high-fidelity fluid-structure interaction simulations have been conducted and a dedicated and novel spectral analysis has been developed to characterise the kinetic energy (KE) carried by eddies in the wavenumber space. In addition, new field quantities, i.e. modal KE anisotropy intensity as well as normalised helicity intensity, are introduced. Spectral analysis shows kinetic energy (KE) decay variations, with the stenotic case aligning with Kolmogorov's theory, while BioAV cases differing. We explore the impact of flow helicity on KE transfer and decay in BioAVs. Probability distributions of modal KE anisotropy unveil flow asymmetries in the stenotic and one BioAV cases. Moreover, an inverse correlation between temporally averaged modal KE anisotropy and normalised instantaneous helicity intensity is noted, with the coefficient of determination varying among the valve configurations. Leaflet dynamics analysis highlights a stronger correlation between flow and biomechanical KE anisotropy in one BioAV due to higher leaflet displacement magnitude. These findings emphasise the role of valve architecture in aortic turbulence as well as its importance for BioAV performance and energy-based design enhancement.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Hemodynamics , Models, Cardiovascular , Humans , Aortic Valve/physiopathology , Aortic Valve/surgery , Anisotropy , Hemodynamics/physiology , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging
17.
Front Biosci (Landmark Ed) ; 29(5): 181, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38812319

ABSTRACT

BACKGROUND: Recent studies highlighted the presence of anti-α-Gal antibodies in patients implanted with commercial bioprosthetic heart valves (BHVs). BHVs expose residual α-Gal xenoantigen and their recognition by the circulating anti-Gal antibodies leads to opsonization of the device's tissue component with the consequent triggering of a deterioration pathway that culminates with calcification. Small animal models such as mice and rats have been broadly involved in the in vivo testing of biomaterials by subcutaneous implantation, especially for the effectiveness of BHVs anti-calcific treatments. However, since models employed for this purpose express α-Gal antigen, the implantation of BHVs' leaflets does not elicit a proper immunological response, so the calcification propensity may be dramatically underestimated. METHODS: An α-Gal knockout (KO) mouse model has been created, using the CRISP/Cas9 approach, and adopted to assess the calcification potential of commercial BHVs leaflets through the surgical implantation in the back subcutis area. Calcium quantification was performed by inductively coupled plasma analysis; immune response against the BHVs leaflets and α-Gal silencing was evaluated through immunological assays. RESULTS: Two months after the implantation of commercial BHV leaflets, the anti-Gal antibody titers in KO mice doubled when compared with those found in wild-type (WT) ones. Leaflets explanted from KO mice, after one month, showed a four-time increased calcium deposition concerning the ones explanted from WT. The degree of silencing of α-Gal varied, depending on the specific organ that was assessed. In any case, the animal model was suitable for evaluating implanted tissue responses. CONCLUSIONS: Such mouse model proved to be an accurate tool for the study of the calcific propensity of commercial BHVs leaflets than those hitherto used. Given its reliability, it could also be successfully used to study even other diseases in which the possible involvement of α-Gal has been observed.


Subject(s)
Bioprosthesis , Calcinosis , Disease Models, Animal , Heart Valve Prosthesis , Mice, Knockout , Animals , Calcinosis/immunology , Calcinosis/etiology , Mice , Mice, Inbred C57BL , Male
18.
Int J Biol Macromol ; 269(Pt 1): 131951, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38710253

ABSTRACT

Bacterial nanocellulose (BNC) is a promising material for heart valve prostheses. However, its low strength properties limit its applicability in cardiovascular surgery. To overcome these limitations, the mechanical properties of BNC can be improved through modifications. The aim of the research was to investigate the extent to which the mechanical properties of BNC can be altered by modifying its structure during its production and after synthesis. The study presents the results of various analyses, including tensile tests, nanoindentation tests, X-ray diffraction (XRD) tests, scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR) and Raman spectroscopy, conducted on BNC chemically modified in situ with hyaluronic acid (BNC/HA) and physically modified ex situ through a dehydration/rehydration process (BNC 25DR, BNC105DR, BNC FDR and BNC/HA 25DR, BNC/HA 105DR, BNC/HA FDR). The results demonstrate that both chemical and physical modifications can effectively shape the mechanical properties of BNC. These modifications induce changes in the crystalline structure, pore size and distribution, and residual stresses of BNC. Results show the effect of the crystalline structure of BNC on its mechanical properties. There is correlation between hardness and Young's modulus and Iα/Iß index for BNC/HA and between creep rate of BNC/HA, and Young's modulus for BNC vs Iα/Iß index.


Subject(s)
Cellulose , Cellulose/chemistry , Heart Valve Prosthesis , Tensile Strength , X-Ray Diffraction , Nanostructures/chemistry , Spectroscopy, Fourier Transform Infrared , Materials Testing , Hyaluronic Acid/chemistry , Mechanical Phenomena , Heart Valves/chemistry
20.
Laeknabladid ; 110(5): 247-253, 2024 May.
Article in Icelandic | MEDLINE | ID: mdl-38713559

ABSTRACT

INTRODUCTION: One of the most serious complications of surgical aortic valve replacement (SAVR) is stroke that can result in increased rates of complications, morbidity and mortality postoperatively. The aim of this study was to investigate incidence, risk factors and short-term outcome in a well defined cohort of SAVR-patients. MATERIALS AND METHOD: A retrospective study on 740 consecutive aortic stenosis patients who underwent SAVR in Iceland 2002-2019. Patients with stroke were compared with non-stroke patients; including preoperative risk factors of cardiovascular disease, echocardiogram-results, rate of early postoperative complications other than stroke and 30 day mortality. RESULTS: Mean age was 71 yrs (34% females) with 57% of the patients receiving stented bioprosthesis, 31% a stentless Freestyle®-valve and 12% a mechanical valve. Mean EuroSCORE-II was 3.6, with a maximum preop-gradient of 70 mmHg and an estimated valvular area of 0.73 cm2. Thirteen (1.8%) patients were diagnosed with stroke where hemiplegia (n=9), loss of consciousness (n=3) and/or aphasia (n=4) were the most common presenting symptoms. In 70% of cases the neurological symptoms resolved or disappeared in the first weeks and months after surgery. Only one patient out of 13 died within 30-days (7.7%). Stroke-patients had significantly lower BMI than non-stroke patients, but other risk factors of cardiovascular diseases, intraoperative factors or the rate of other severe postoperative complications than stroke were similar between groups. Total length of stay was 14 days vs. 10 days median, including 2 vs. 1 days in the ICU, in the stroke and non-stroke-groups, respectively. CONCLUSIONS: The rate of stroke after SAVR was low (1.8%) and in line with other similar studies. Although a severe complication, most patients with perioperative stroke survived 30 days postoperatively and in majority of cases neurological symptoms recovered.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Stroke , Humans , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Male , Aged , Risk Factors , Retrospective Studies , Iceland/epidemiology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/instrumentation , Stroke/epidemiology , Stroke/mortality , Stroke/etiology , Incidence , Time Factors , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Risk Assessment , Aged, 80 and over , Middle Aged