Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 6.871
Filter
1.
Cochrane Database Syst Rev ; 5: CD013421, 2024 05 02.
Article in English | MEDLINE | ID: mdl-38695613

ABSTRACT

BACKGROUND: During vascular interventions, connections that link arteries, veins, or synthetic grafts, which are known as an 'anastomosis', may be necessary. Vascular anastomoses can bleed from the needle holes that result from the creation of the anastomoses. Various surgical options are available for achieving hemostasis, or the stopping of bleeding, including the application of sealants directly onto the bleeding vessels or tissues. Sealants are designed for use in vascular surgery as adjuncts when conventional interventions are ineffective and are applied directly by the surgeon to seal bleeding anastomoses. Despite the availability of several different types of sealants, the evidence for the clinical efficacy of these hemostatic adjuncts has not been definitively established in vascular surgery patients. OBJECTIVES: To evaluate the benefits and harms of sealants as adjuncts for achieving anastomotic site hemostasis in patients undergoing vascular surgery. SEARCH METHODS: The Cochrane Vascular Information Specialist conducted systematic searches of the following databases: the Cochrane Vascular Specialised Register via the Cochrane Register of Studies; the Cochrane Central Register of Controlled Trials (CENTRAL); MEDLINE via Ovid; Embase via Ovid ; and CINAHL via EBSCO. We also searched ClinicalTrials.gov and the WHO International Clinical Trials Registry Platform for clinical trials. Reference lists of included trials and relevant reviews were also searched. The latest search date was 6 March 2023. SELECTION CRITERIA: We included randomized controlled trials that compared fibrin or synthetic sealant use with alternative interventions (e.g. manual compression, reversal of anticoagulation) for achieving anastomotic-site hemostasis in vascular surgery procedures. We included participants who underwent the creation of an anastomosis during vascular surgery. We excluded non-vascular surgery patients. DATA COLLECTION AND ANALYSIS: We have used standard Cochrane methods. Our primary outcomes were time to hemostasis, failure of hemostatic intervention, and intraoperative blood loss. Our secondary outcomes were operating time, death from bleeding complications up to 30 days, postoperative bleeding up to 30 days, unplanned return to the operating room for bleeding complications management up to 30 days, quality of life, and adverse events. We used GRADE to assess the certainty of evidence for each outcome. MAIN RESULTS: We found 24 randomized controlled trials that included a total of 2376 participants who met the inclusion criteria. All trials compared sealant use with standard care controls, including oxidized cellulose, gelatin sponge, and manual compression. All trials were at high risk of performance bias, detection bias, and other sources of bias. We downgraded the certainty of evidence for risk of bias concerns, inconsistency, imprecision and possible publication bias. Combining data on time to hemostasis showed that sealant use may reduce the mean time to hemostasis compared to control (mean difference (MD) -230.09 seconds, 95% confidence interval (CI) -329.24 to -130.94; P < 0.00001; 7 studies, 498 participants; low-certainty evidence). Combining data on failure of hemostatic intervention showed that sealant use may reduce the rate of failure compared to control, but the evidence is very uncertain (risk ratio (RR) 0.46, 95% CI 0.35 to 0.61; P < 0.00001; 17 studies, 2120 participants; very low-certainty evidence). We did not detect any clear differences between the sealant and control groups for intraoperative blood loss (MD -32.69 mL, 95% CI -96.21 to 30.83; P = 0.31; 3 studies, 266 participants; low-certainty evidence); operating time (MD -18.72 minutes, 95% CI -40.18 to 2.73; P = 0.09; 4 studies, 436 participants; low-certainty evidence); postoperative bleeding (RR 0.78, 95% CI 0.59 to 1.04; P = 0.09; 9 studies, 1216 participants; low-certainty evidence), or unplanned return to the operating room (RR 0.27, 95% CI 0.04 to 1.69; P = 0.16; 8 studies, 721 participants; low-certainty evidence). No studies reported death from bleeding or quality of life outcomes. AUTHORS' CONCLUSIONS: Based on meta-analysis of 24 trials with 2376 participants, our review demonstrated that sealant use for achieving anastomotic hemostasis in vascular surgery patients may result in reduced time to hemostasis, and may reduce rates of hemostatic intervention failure, although the evidence is very uncertain, when compared to standard controls. Our analysis showed there may be no differences in intraoperative blood loss, operating time, postoperative bleeding up to 30 days, and unplanned return to the operating room for bleeding complications up to 30 days. Deaths and quality of life could not be analyzed. Limitations include the risk of bias in all studies. Our review has demonstrated that using sealants may reduce the time required to achieve hemostasis and the rate of hemostatic failure. However, a significant risk of bias was identified in the included studies, and future trials are needed to provide unbiased data and address other considerations such as cost-effectiveness and adverse events with sealant use.


Subject(s)
Anastomosis, Surgical , Hemostasis, Surgical , Randomized Controlled Trials as Topic , Vascular Surgical Procedures , Humans , Hemostasis, Surgical/methods , Hemostatics/therapeutic use , Fibrin Tissue Adhesive/therapeutic use , Blood Loss, Surgical/prevention & control , Tissue Adhesives/therapeutic use
2.
Surg Endosc ; 38(5): 2331-2343, 2024 May.
Article in English | MEDLINE | ID: mdl-38630180

ABSTRACT

BACKGROUND: The use of hemostatic agents by general surgeons during abdominal operations is commonplace as an adjunctive measure to minimize risks of postoperative bleeding and its downstream complications. Proper selection of products can be hampered by marginal understanding of their pharmacokinetics and pharmacodynamics. While a variety of hemostatic agents are currently available on the market, the choice of those products is often confusing for surgeons. This paper aims to summarize and compare the available hemostatic products for each clinical indication and to ultimately better guide surgeons in the selection and proper use of hemostatic agents in daily clinical practice. METHODS: We utilized PubMed electronic database and published product information from the respective pharmaceutical companies to collect information on the characteristics of the hemostatic products. RESULTS: All commercially available hemostatic agents in the US are described with a description of their mechanism of action, indications, contraindications, circumstances in which they are best utilized, and expected results. CONCLUSION: Hemostatic products come with many different types and specifications. They are valuable tools to serve as an adjunct to surgical hemostasis. Proper education and knowledge of their characteristics are important for the selection of the right agent and optimal utilization.


Subject(s)
Hemostasis, Surgical , Hemostatics , Humans , Hemostatics/therapeutic use , Hemostatics/pharmacology , Hemostasis, Surgical/methods , Postoperative Hemorrhage/prevention & control , Blood Loss, Surgical/prevention & control
3.
J Surg Res ; 298: 316-324, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38640617

ABSTRACT

INTRODUCTION: Intraoperative blood loss and postoperative hemorrhage affect outcomes after liver resection. GATT-Patch is a new flexible, pliable hemostatic sealant patch comprising fibrous gelatin carrier impregnated with N-hydroxy-succinimide polyoxazoline. We evaluated safety and performance of the GATT-Patch for hemostasis at the liver resection plane. METHODS: Adult patients undergoing elective open liver surgery were recruited in three centers. GATT-Patch was used for minimal to moderate bleeding at the liver resection plane. The primary endpoint was hemostasis of the first-treated bleeding site at 3 min versus a prespecified performance goal of 65.4%. RESULTS: Two trial stages were performed: I (n = 8) for initial safety and II (n = 39) as the primary outcome cohort. GATT-Patch was applied in 47 patients on 63 bleeding sites. Median age was 60.0 (range 25-80) years and 70% were male. Most (66%) surgeries were for colorectal cancer metastases. The primary endpoint was met in 38 out of 39 patients (97.4%; 95% confidence interval: 84.6%-99.9%) versus 65.4% (P < 0.001). Of all the 63 bleeding sites, hemostasis was 82.7% at 30, 93.7% at 60, and 96.8% at 180 s. No reoperations for rebleeding or device-related issues occurred. CONCLUSIONS: When compared to a performance goal derived from state-of-the-art hemostatic agents, GATT-Patch for the treatment of minimal to moderate bleeding during liver surgery successfully and quickly achieved hemostasis with acceptable safety outcomes. (ClinicalTrials.gov Identifier: NCT04819945).


Subject(s)
Blood Loss, Surgical , Hepatectomy , Humans , Male , Middle Aged , Female , Aged , Adult , Hepatectomy/adverse effects , Hepatectomy/methods , Aged, 80 and over , Blood Loss, Surgical/statistics & numerical data , Blood Loss, Surgical/prevention & control , Hemostasis, Surgical/methods , Hemostasis, Surgical/instrumentation , Hemostatics/administration & dosage , Hemostatics/therapeutic use , Hemostatics/adverse effects , Treatment Outcome , Gelatin/adverse effects , Gelatin/administration & dosage , Prospective Studies , Liver Neoplasms/surgery , Liver Neoplasms/secondary
4.
Innovations (Phila) ; 19(2): 143-149, 2024.
Article in English | MEDLINE | ID: mdl-38504149

ABSTRACT

OBJECTIVE: This study evaluated the efficacy of the Minimally Invasive Targeted Resection (MiTR) device, a novel electrosurgical instrument that allows for targeted excision of a lung abnormality while using bipolar radiofrequency (RF) energy to seal blood vessels and airways. METHODS: The MiTR system was evaluated in 7 acute and 2 chronic porcine (7-day) models to evaluate the efficacy of tissue excision with bipolar RF sealing of blood vessels and airways and application of an autologous blood patch into the excised tissue cavity. Air leak was recorded for all evaluations. The study was approved by the institutional ethical board. RESULTS: Nineteen lung tissue samples, measuring 2.5 cm long × 1.2 cm diameter, were excised. In 8 of 9 animals (89%), hemostasis and pneumostasis were observed visually at the completion of the procedure. In 2 of 2 chronic animals (100%), hemostasis and pneumostasis persisted for the 7-day observation period. Histologic examination of the excised samples showed preservation of the core parenchymal architecture without evident tissue damage of the samples that would impair pathologic analysis. CONCLUSIONS: Percutaneous resection of targeted lung tissue with the MiTR system demonstrated hemostasis and pneumostasis while obtaining a histologically intact sample. After regulatory approval, the use of this device could offer more tissue for analysis than a transthoracic needle biopsy or bronchoscopy and a far less invasive alternative to video-assisted thoracic surgery or thoracotomy. This may also expand patient and physician options for the early diagnosis and treatment of lung cancer.


Subject(s)
Lung , Animals , Swine , Lung/surgery , Lung/pathology , Pneumonectomy/instrumentation , Pneumonectomy/methods , Electrosurgery/instrumentation , Electrosurgery/methods , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/instrumentation , Hemostasis, Surgical/instrumentation , Hemostasis, Surgical/methods , Surgery, Computer-Assisted/methods , Surgery, Computer-Assisted/instrumentation
5.
Auris Nasus Larynx ; 51(3): 512-516, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38522355

ABSTRACT

Hemostatic procedures for controlling nasal bleeding in refractory diseases such as hereditary hemorrhagic telangiectasia (HHT) can be challenging. In this report, we present a novel technique for underwater endoscopic endonasal hemostatic surgery, which was performed on a 69-year-old man with HHT. The patient had been experiencing frequent episodes of nasal bleeding and had many telangiectasias in the nasal cavity, which were the cause of the bleeding. These telangiectasias were effectively treated using a coblation device in combination with an endoscope lens-cleaning system that supplied saline to create stable underwater conditions. There are several advantages to this technique, including provision of a stable and clear endoscopic field of view, allowing for better visualization of the surgical site. This makes it easier to identify bleeding points and ensure accurate hemostasis. Additionally, the hydrostatic pressure created by the underwater environment helps to reduce bleeding during the procedure. However, it is important to take careful precautions to prevent water from entering the lower airway. With this precautionary measure, this technique is particularly useful in managing bleeding in patients with HHT.


Subject(s)
Epistaxis , Telangiectasia, Hereditary Hemorrhagic , Humans , Telangiectasia, Hereditary Hemorrhagic/complications , Telangiectasia, Hereditary Hemorrhagic/surgery , Aged , Male , Epistaxis/surgery , Nasal Cavity/surgery , Hemostasis, Endoscopic/methods , Hemostasis, Endoscopic/instrumentation , Endoscopy/methods , Natural Orifice Endoscopic Surgery/methods , Hemostasis, Surgical/methods , Hemostasis, Surgical/instrumentation
6.
J Clin Neurosci ; 120: 30-35, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38176112

ABSTRACT

Intraoperative bleeding poses a substantial challenge, particularly in neuro-spine surgeries leading to complications such as hematomas, infections, and hemodynamic instability. Despite their proven efficacy, use of topical hemostatic agents (THAs) lacks comprehensive published literature and guidelines particularly in the Indian setting. The present study provides the first-ever Indian expert panel recommendations for effective adjunct THA use in different intraoperative bleeding sites and situations in neuro-spine surgeries. A comprehensive approach, encompassing a literature review, followed by experience sharing in a meeting using a survey helped integrate expert opinions in the form of practical algorithms to guide THA selection. Our survey results revealed a strong inclination towards specific THAs, flowable gelatin + thrombin being choice of THA for difficult to access and problematic bleeding situations during tumor removal/resection, transsphenoidal hypophysectomy and skull-based procedures. Both oxidized regenerated cellulose (ORC)/Fibrillar and flowable gelatin + thrombin were recommended for continuous oozing. ORC/Fibrillar was preferred for arteriovenous and cavernous malformations. This expert-panel guidance on THA use aims to optimize hemostat use practices and improve surgical outcomes in neuro-spine surgery.


Subject(s)
Hemostatics , Humans , Hemostatics/therapeutic use , Thrombin/therapeutic use , Gelatin , Hemostasis, Surgical , Blood Loss, Surgical/prevention & control
7.
Spine J ; 24(6): 933-946, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38219838

ABSTRACT

Spinal surgery can be associated with significant intraoperative blood loss which may lead to various complications. As the number of patients undergoing spinal surgery increases over time, accurate and effective hemostasis becomes critically important. Despite various surgical hemostatic techniques, conventional interventions such as compression, suture, ligation, and heat-generating cautery, are not suitable for osseous and epidural venous plexus bleeding during spinal procedures. Therefore, a variety of hemostatic agents have been developed to promote hemostasis. As they differ in terms of mechanism, form, application and potential adverse reactions, it is important to understand the natural features of existing agents. Here we comprehensively review currently available topical hemostatic agents from different sources and summarize their mechanisms of action, applications, and current or potential utilization in spinal surgery. We found hemostatic agents from different sources exert hemostatic actions through different mechanisms. In addition, topical hemostatic agents play various roles in spinal surgery including as hemostatic agent, dura mater repair, drug-carrier, skin closure, and fibrosis prevention. Compressive neurological complications are the most common complications of these hemostatic agents. Therefore, optimal use in spinal environments should match their features, indications, and efficacy with clinical conditions.


Subject(s)
Blood Loss, Surgical , Hemostatics , Spine , Humans , Hemostatics/administration & dosage , Hemostatics/adverse effects , Spine/surgery , Blood Loss, Surgical/prevention & control , Administration, Topical , Hemostasis, Surgical/methods
9.
BMC Pregnancy Childbirth ; 24(1): 9, 2024 Jan 02.
Article in English | MEDLINE | ID: mdl-38166803

ABSTRACT

BACKGROUND: Intractable postpartum hemorrhage (PPH) during cesarean section has been a significant concern for obstetricians. We aimed to explore the effectiveness and safety of a new type of uterine compression suture, the step-wise surgical technique of knapsack-like sutures for treating intractable PPH caused by uterine atony and placenta factors in cesarean section. METHODS: The step-wise surgical technique of knapsack-like sutures was established on the basis of the artful combination of vertical strap-like sutures and an annular suture-ligation technique. This novel surgical technique was applied to 34 patients diagnosed with PPH during cesarean section due to severe uterine atony and placental factors in our department. The hemostatic effects, clinical outcomes and follow-up visit results were all reviewed and analyzed. RESULTS: This new uterine compression suture successfully stopped bleeding in 33 patients, and the effective rate was 97.06%. Only 1 patient failed and was changed to use bilateral uterine arterial embolization and internal iliac artery embolization. The follow-up visits indicated that 33 patients restored menstruation except for 1 who was diagnosed with amenorrhea. The gynecological ultrasound tests of all the patients suggested good uterine involutions, and they had no obvious complaints such as hypogastralgia. CONCLUSIONS: This step-wise surgical technique of knapsack-like uterine compression sutures can compress the uterus completely. It is a technique that can conserve the uterus and fertility function without special equipment in caesarean section for PPH, with the characteristics of being safe, simple and stable (3 S) with rapid surgery, reliable hemostasis and resident doctor to operation (3R).


Subject(s)
Postpartum Hemorrhage , Uterine Inertia , Female , Humans , Pregnancy , Postpartum Hemorrhage/surgery , Postpartum Hemorrhage/etiology , Cesarean Section/adverse effects , Uterine Inertia/surgery , Hemostasis, Surgical/methods , Placenta/surgery , Uterus/surgery , Uterus/blood supply , Sutures/adverse effects , Suture Techniques/adverse effects
10.
J Neurosurg ; 140(2): 595-599, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-37503914

ABSTRACT

Prior to the 1937 invention of the Raney clip, surgeons relied on hemostatic sutures, pneumatic tourniquets, sequentially applied hemostatic forceps, and the administration of local vasoconstrictive agents to achieve scalp hemostasis. The Raney clip is now the quintessential tool for achieving scalp hemostasis in cranial neurosurgery; with nearly 13.8 million cranial neurosurgical cases per year globally, Raney clips are in high demand and their use is ubiquitous. What is less known, however, is the story of their invention and the related stories of those who bear the Raney name. This paper fills these gaps in neurosurgical history, using information obtained during an extensive series of contemporary interviews and correspondence with the Raney family.


Subject(s)
Hemostasis, Surgical , Hemostatics , Humans , Eponyms , Neurosurgical Procedures , Surgical Instruments
11.
Gen Thorac Cardiovasc Surg ; 72(5): 331-337, 2024 May.
Article in English | MEDLINE | ID: mdl-37837565

ABSTRACT

BACKGROUND: Advanced vessel sealing electrosurgical systems have been widely adopted for grasping, cutting, and sealing vessels. Data remain sparse with regard to its use in thoracic procedures. Thus, a prospective case series, utilizing the ENSEAL X1 Curved Jaw Tissue Sealer (X1CJ) and its companion energy source, the Generator 11 (GEN11), in thoracic procedures was performed in a Japanese cohort. METHODS: Subjects were recruited at two Japanese surgical sites. The primary endpoint of this post-market study was the achievement of hemostasis (≤ Grade 3) for each thoracic vessel transection. Performance endpoints included scores for tasks completed with X1CJ (adhesiolysis, lymphatics or tissue bundles divided, tissue grasping, tissue cutting, or tissue dissection); hemostasis grading vessel transected; additional products required to achieve hemostasis for Grade 4 vessel transections. Safety was evaluated by evaluating device-related adverse events. All endpoint data were summarized. RESULTS: Forty subjects (50.0% female) of Asian ethnicity with a mean age of 67.6 ± 11.3 years underwent a lung resection. Estimated mean blood loss was 39.5 mL. Hemostasis was achieved in 97.5% of vessel transections. Thirty-seven vessel sealings resulted in a hemostatic Grade 1 (92.5%). All surgeons reported satisfaction/neutral in terms of tissue grasping (100.0%) while most reported satisfaction/neutral with tissue cutting (95.7%). One device-related serious adverse event was reported (2.5%), a chylothorax requiring an extension of hospitalization. There was no post-operative bleeding or deaths reported during the study period. CONCLUSION: The X1CJ demonstrated safe and effective performance without any reports of significant intra-operative or post-operative hemorrhage in thoracic vessel sealing.


Subject(s)
Hemostasis, Surgical , Postoperative Hemorrhage , Humans , Female , Middle Aged , Aged , Male , Hemostasis, Surgical/methods , Japan , Postoperative Hemorrhage/etiology
12.
Rev. bras. oftalmol ; 83: e0009, 2024. tab, graf
Article in Portuguese | LILACS | ID: biblio-1535599

ABSTRACT

RESUMO Objetivo: Avaliar o efeito do colírio de brimonidina 0,2% na redução da hiperemia e do sangramento ocular durante as cirurgias de estrabismo, em comparação com o colírio de nafazolina 0,025% + feniramina 0,3%. Métodos: Foram avaliados 14 pacientes com estrabismo e indicação de correção cirúrgica bilateral. Foi instilado antes do procedimento, de forma aleatória, um colírio em cada olho dos pacientes avaliados. A análise subjetiva da hiperemia conjuntival e do sangramento perioperatório foi realizada de forma duplo-cega, por dois cirurgiões. A avaliação objetiva do nível de hiperemia conjuntival foi realizada por análise das imagens obtidas por meio do software ImageJ®. Resultados: A análise de modelos multivariados de efeito misto indicou diferenças estatisticamente significantes entre os grupos em relação à hiperemia (avaliador 2) e ao sangramento intraoperatório (avaliadores 1 e 2), com maiores escores nos casos tratados com colírio de nafazolina + feniramina. Entretanto, não houve diferença estatística na análise objetiva realizada por meio da saturação de cores obtidas pelo programa ImageJ®. Conclusão: O colírio de brimonidina pode ser superior ao colírio de nafazolina + feniramina na redução do sangramento, levando-se em conta apenas a análise subjetiva.


ABSTRACT Objective: To evaluate the effect of 0.2% brimonidine eye drops in reducing hyperemia and ocular bleeding during strabismus surgeries, in comparison with 0.025% naphazoline + 0.3% pheniramine eye drops. Methods: Fourteen patients with strabismus and indication for bilateral surgical correction were evaluated. Before the procedure, the eye drops were instilled randomly in each eye of the evaluated patients. The subjective analysis of conjunctival hyperemia and perioperative bleeding was performed in a double-blind manner, by 02 surgeons. The objective assessment of the level of conjunctival hyperemia was performed by analyzing the images obtained using the ImageJ® software. Results: The analysis of multivariate mixed effect models indicated statistically significant differences between the groups in relation to hyperemia (rater 2) and intraoperative bleeding (raters 1 and 2) with higher scores in cases treated with naphazoline + pheniramine eye drops. However, there were no statistically significant differences in the objective analysis of color saturation obtained by the ImageJ® program. Conclusion: Brimonidine eye drops may be superior to naphazoline + pheniramine eye drops in reducing bleeding, taking into account the subjective analysis only.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Pheniramine/administration & dosage , Eye Hemorrhage/prevention & control , Strabismus/surgery , Brimonidine Tartrate/administration & dosage , Hyperemia/prevention & control , Intraoperative Complications/prevention & control , Naphazoline/administration & dosage , Ophthalmic Solutions/administration & dosage , Premedication , Ophthalmologic Surgical Procedures/methods , Vasoconstriction/drug effects , Photography , Double-Blind Method , Administration, Topical , Adrenergic alpha-2 Receptor Agonists/administration & dosage , Hemostasis, Surgical/methods
13.
Am J Cardiol ; 209: 181-183, 2023 12 15.
Article in English | MEDLINE | ID: mdl-37863115

ABSTRACT

Suture-mediated closure device and Figure-of-Eight suture are commonly used to achieve hemostasis after use of large bore venous access. Although both methods of closure are commonly used in clinical practice, a head-to-head comparison in a controlled setting has not been performed. Patients presenting to a single center for elective left atrial appendage occlusion or transcatheter edge-to-edge mitral valve repair were randomized to large bore venous closure using the Perclose ProGlide suture-based closure or a Figure-of-Eight suture closure. The patients were followed for 1 month after the procedure. Primary outcome, a composite of access site large ecchymosis, hematoma, infection, pain, need for unscheduled venous ultrasound and need for transfusion, was compared between the 2 arms. A total of 40 patients were randomized in a 1:1 fashion to the 2 venous closure strategies. Baseline characteristics were similar between the 2 groups. Perclose ProGlide arm required use of more devices for hemostasis (1.5 ± 0.5 vs 1 ± 0 respectively, p <0.0001), and there was a significant difference in the cost of closure device ($367.00 ± 122.00 vs $1.00 ± 0 respectively, p <0.001). At 1 month post-procedure, the primary outcome occurred in 4 patients (20%) in the Perclose arm and 7 (35%) patients in the Figure-of-Eight arm, a difference that was not statistically significant (p = 0.48). Time to hemostasis between Figure-of-Eight and Perclose arms did not reach statistical significance (2.5 ± 2.1 vs 3.7 ± 2.3, p = 0.09). In conclusion, both Perclose ProGlide suture-based device and Figure-of-Eight closure are equally feasible and safe for patients who underwent large bore venous access. Figure-of-Eight-based closure is more cost effective.


Subject(s)
Hemostasis, Surgical , Vascular Closure Devices , Humans , Femoral Artery/surgery , Hemostasis , Hemostasis, Surgical/methods , Hemostatic Techniques , Suture Techniques , Sutures , Treatment Outcome , Vascular Surgical Procedures
14.
World Neurosurg ; 178: 241-259.e3, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37586555

ABSTRACT

BACKGROUND: Hemostasis is crucial in preventing hemorrhage during cranial neurosurgical procedures and maintaining visualization of the surgical field. There is significant variation in the availability of hemostatic methods across different settings and hemostatic techniques are being continuously developed over the decades of practicing neurosurgery. The aim of this article is to provide an outline of the potential methods to achieve hemostasis based on the sequential operative anatomy of a cranial operation. METHODS: A systematic review was conducted following the PRISMA guidelines. The PubMed database was searched from inception of the database to July 18, 2023. A total of 64 studies were identified fulfilling predefined inclusion criteria, and the risk of bias was assessed using the Joanna Briggs Institute checklists. RESULTS: Seventy-one hemostatic agents, techniques, tools, and devices were identified, which were then categorized according to the operative phase for which they are indicated. Nine operative anatomic targets were addressed in the sequence in which they are involved during a cranial procedure. For each anatomic target, the following number of hemostatic techniques/agents were identified: 11 for scalp, 3 for periosteum, 10 for skull bone, 11 for dura mater, 9 for venous sinuses, 5 for arteries, 6 for veins, 12 for brain parenchyma, and 4 for cerebral ventricles. CONCLUSIONS: Depending on the phase of the surgery and the anatomic structure involved, the selection of the appropriate hemostatic method is determined by the source of bleeding. Surgeon awareness of all the potential techniques that can be applied to achieve hemostasis is paramount, especially when faced with operative nuances and difficult-to-control bleeding during cranial neurosurgical procedures.


Subject(s)
Hemostatics , Neurosurgery , Humans , Hemostatics/therapeutic use , Neurosurgical Procedures/methods , Hemostasis , Skull/surgery , Hemostasis, Surgical/methods
15.
J Pediatr Adolesc Gynecol ; 36(6): 563-565, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37558158

ABSTRACT

BACKGROUND: A longitudinal vaginal septum (LVS) is a rare congenital anomaly often identified during adolescence. Surgical removal is a mainstay in treatment of symptomatic cases; however, there is variation in the techniques used. Little is known about the risk for postoperative complications associated with novel methods. CASES: We present the cases of 2 adolescent females, ages 15 and 22, diagnosed with an LVS who elected to undergo surgical removal. A LigaSure device was used for resection, and both individuals experienced significant postoperative bleeding almost 2 weeks following resection. SUMMARY AND CONCLUSIONS: This report outlines two occurrences of postoperative bleeding after LVS resection, which may suggest inadequate surgical site hemostasis with use of the LigaSure apparatus. Further research on outcomes related to this technique is needed.


Subject(s)
Hemostasis, Surgical , Vaginal Diseases , Female , Adolescent , Humans , Hemostasis, Surgical/methods , Vaginal Diseases/surgery , Postoperative Complications/etiology
16.
Eur Rev Med Pharmacol Sci ; 27(13): 6223-6228, 2023 07.
Article in English | MEDLINE | ID: mdl-37458629

ABSTRACT

OBJECTIVE: The usage of vessel sealing devices has been gaining popularity in all surgical specialties. Post-renal transplant drain placement is a common practice among transplant surgeons. However, prolonged drainage accompanied by surgical wound complications and perirenal fluid collections is a frequent complication experienced by the recipients. This study aimed to compare Bipolar vascular sealing with conventional back-table dissection in terms of post-renal transplant drainage duration, amount, surgical wound complication, and back-table preparation time. PATIENTS AND METHODS: A double-blind clinical study randomizes recipients into 2 groups, using Bipolar vascular sealing (Group 1) and conventional ligation (Group 2) back-table dissection. Variables such as recipient age, gender, body mass index (BMI), cause of end-stage renal disease, amount and duration of surgical drainage, back-table time, and cold ischemia time (CIT) were collected prospectively. RESULTS: Ninety-eight consecutive living donor (M/F: 69/29) renal transplant recipients were enrolled in this prospective randomized clinical trial. There were 49 patients in each group. The mean BMI was 26.76±4.57. There was no difference among the groups regarding recipient age, BMI, total drainage, and surgical drainage duration. The surgical site infection rate was not different between the two groups. Group 1 had significantly shorter back-table time, with mean back-table time being 15.26±2.51 minutes in Group 1 and 28.83±6.27 minutes in Group 2 (p<0.001). The CIT was also significantly different between the 2 groups (p<0.001). In Group 1, the recorded CIT was 43.3±11.4, and in Group 2, 57.1±13.3 minutes. CONCLUSIONS: The use of Bipolar vascular sealing to seal lymphatic vessels at the back-table is feasible, safe, and easy to perform. It also expedites the dissection and shortens the time required for back-table graft preparation.


Subject(s)
Kidney Transplantation , Surgical Wound , Humans , Kidney Transplantation/adverse effects , Prospective Studies , Hemostasis, Surgical , Drainage
18.
J Clin Neurosci ; 114: 70-76, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37321020

ABSTRACT

OBJECTIVE: Rapid and efficacious haemostasis is paramount in neurosurgery. Assessing the efficacy and short- and long-term safety of haemostatic agents utilised within cerebral tissue is essential. This pilot study investigates the haemostatic efficacy and long-term safety of a novel beta-chitin patch against traditionally used agents, bipolar and Floseal, within cerebral tissue. METHODS: Eighteen Merino sheep underwent standardised distal cortical vessel injury via temporal craniotomy. Sheep were randomised to receive 2 mls Floseal, 2 cm novel beta-chitin patch, or bipolar cautery to manage bleeding. All sheep underwent cerebral magnetic resonance imaging (MRI) at three months, before euthanasia and brain harvesting for histological assessment. RESULTS: Beta-chitin demonstrated a trend towards a faster mean time to haemostasis (TTH) compared to Floseal (223.3 ± 199 s v. 259.8 ± 186.4 s), albeit non-significant (p = 0.234). Radiologically, cerebrocortical necrosis (p = 0.842) and oedema (p = 0.368) were noted slightly more frequently in the beta-chitin group. Histologically, severe fibrotic (p = 0.017) and granulomatous changes at the craniotomy sites were only present in the beta-chitin group (p = 0.002). Neuronal degeneration was seen in all with Floseal, but beta-chitin showed a trend towards more severe reaction when present. Bipolar use predominantly showed an inflammatory cortical reaction with substantial microvascular proliferation, and Floseal showed worse severity and depth of subpial oedema, however no statistical significance was reached. CONCLUSION: All haemostats controlled bleeding, with beta-chitin demonstrating a non-inferior TTH compared to Floseal. However, it resulted in intense granulomatous and fibrotic changes, including degenerative neuronal reactions. More extensive studies are needed to assess these trends, to make further clinical inferences.


Subject(s)
Hemostatics , Sheep , Animals , Hemostatics/pharmacology , Pilot Projects , Gelatin Sponge, Absorbable , Hemostasis , Hemostasis, Surgical/methods , Chitin/pharmacology , Chitin/therapeutic use
19.
Eur Rev Med Pharmacol Sci ; 27(3 Suppl): 135-140, 2023 04.
Article in English | MEDLINE | ID: mdl-37129324

ABSTRACT

Sufficient hemostasis during oral surgical procedures is crucial for successful outcomes and to reduce healthcare resource utilization. The purpose of this narrative review is to give a rational insight into the management of bleeding in oral and dental practice through modern drugs. A narrative literature review has been performed on the present topic identifying all articles on Pubmed/Medline and Google Scholars. Acceptable hemostasis during oral surgery is also required to improve visibility and provide a dry operational area. Many oral surgeons, in their daily practice, encounter problems in controlling postoperative bleeding and use a topical hemostatic agent to promote platelet activation or aggregation to form a stable clot.


Subject(s)
Hemostatics , Oral Surgical Procedures , Humans , Postoperative Hemorrhage , Hemostasis, Surgical/methods , Hemostasis , Hemostatics/pharmacology , Blood Loss, Surgical , Administration, Topical
SELECTION OF CITATIONS
SEARCH DETAIL
...