Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.657
Filter
1.
J Investig Med High Impact Case Rep ; 12: 23247096241258063, 2024.
Article in English | MEDLINE | ID: mdl-38828786

ABSTRACT

Hepatic encephalopathy is uncommon in the absence of cirrhosis. We report a 71-year-old woman who presented with altered mental status in the setting of hyperammonemia for the second time in 6 months. Magnetic resonance imaging of the abdomen revealed an uncommon portosystemic shunt involving an enlarged posterior branch of the right portal vein and an accessory right hepatic vein, with no features of cirrhosis. Appropriate management of these patients with ammonia-lowering therapy can reduce repeat episodes and improve quality of life. This case demonstrates the importance of diagnosing non-cirrhotic hepatic encephalopathy in patients with altered mental status.


Subject(s)
Hepatic Encephalopathy , Hyperammonemia , Magnetic Resonance Imaging , Portal Vein , Humans , Hepatic Encephalopathy/etiology , Female , Aged , Portal Vein/abnormalities , Portal Vein/diagnostic imaging , Hyperammonemia/etiology , Hepatic Veins/abnormalities , Hepatic Veins/diagnostic imaging
2.
Radiographics ; 44(5): e230115, 2024 May.
Article in English | MEDLINE | ID: mdl-38662586

ABSTRACT

Adrenal vein sampling (AVS) is the standard method for distinguishing unilateral from bilateral sources of autonomous aldosterone production in patients with primary aldosteronism. This procedure has been performed at limited specialized centers due to its technical complexity. With recent advances in imaging technology and knowledge of adrenal vein anatomy in parallel with the development of adjunctive techniques, AVS has become easier to perform, even at nonspecialized centers. Although rare, anatomic variants of the adrenal veins can cause sampling failure or misinterpretation of the sampling results. The inferior accessory hepatic vein and the inferior emissary vein are useful anatomic landmarks for right adrenal vein cannulation, which is the most difficult and crucial step in AVS. Meticulous assessment of adrenal vein anatomy on multidetector CT images and the use of a catheter suitable for the anatomy are crucial for adrenal vein cannulation. Adjunctive techniques such as intraprocedural cortisol assay, cone-beam CT, and coaxial guidewire-catheter techniques are useful tools to confirm right adrenal vein cannulation or to troubleshoot difficult blood sampling. Interventional radiologists should be involved in interpreting the sampling results because technical factors may affect the results. In rare instances, bilateral adrenal suppression, in which aldosterone-to-cortisol ratios of both adrenal glands are lower than that of the inferior vena cava, can be encountered. Repeat sampling may be necessary in this situation. Collaboration with endocrinology and laboratory medicine services is of great importance to optimize the quality of the samples and for smooth and successful operation. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material.


Subject(s)
Adrenal Glands , Hyperaldosteronism , Humans , Adrenal Glands/blood supply , Adrenal Glands/diagnostic imaging , Aldosterone/blood , Anatomic Landmarks , Hepatic Veins/diagnostic imaging , Hyperaldosteronism/diagnostic imaging , Multidetector Computed Tomography/methods , Radiography, Interventional/methods , Veins/diagnostic imaging
3.
Ann Surg Oncol ; 31(6): 4030, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38506935

ABSTRACT

BACKGROUND: Laparoscopic right anterior sectionectomy (LRAS) remains a technically demanding procedure as it requires two transection planes where the middle and right hepatic veins run; however, the main difficulty is locating these two planes1-3. The aim of this video was to show the technique of an LRAS performed with a transparenchymal glissonean pedicle approach and guided by indocyanine green (ICG) staining. METHODS: This was the case of an 80-year-old man with a history of hemochromatosis and normal liver function. He was diagnosed with a 6 cm hepatocellular carcinoma (HCC) located at segment 8, close to the right anterior pedicle. RESULTS: The technique consisted of parenchymal transection along the main portal fissure along the right border of the middle hepatic vein. Opening the liver facilitated access to the right anterior glissonean pedicle and selective transparenchymal clamping. A negative-stain ICG test permitted to demarcate the transection line along the right lateral portal fissure. The parenchymal transection was carried out in a caudal approach, along two perfectly marked planes, preserving the middle and right hepatic veins. The duration of the procedure was 200 min and blood loss was 300 mL. Postoperative course was uneventful and the patient was discharged on the third postoperative day. CONCLUSION: Guidance during resection, and protection of the right posterior pedicle and right hepatic vein are the key points of the LRAS. The glissonean approach and the ICG imaging technology are of great help in resolving these difficulties.


Subject(s)
Carcinoma, Hepatocellular , Hepatectomy , Indocyanine Green , Laparoscopy , Liver Neoplasms , Humans , Male , Liver Neoplasms/surgery , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/pathology , Hepatectomy/methods , Aged, 80 and over , Laparoscopy/methods , Carcinoma, Hepatocellular/surgery , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/pathology , Coloring Agents , Optical Imaging/methods , Hepatic Veins/surgery , Hepatic Veins/diagnostic imaging , Prognosis
4.
HPB (Oxford) ; 26(6): 764-771, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38480098

ABSTRACT

BACKGROUND: Optimisation of the future liver remnant (FLR) is crucial to outcomes of extended liver resections. This study aimed to assess the quality of the FLR before and after dual vein embolization (DVE) by quantitative multiparametric MRI. METHODS: Of 100 patients with liver metastases recruited in a clinical trial (Precision1:NCT04597710), ten consecutive patients with insufficient FLR underwent quantitative multiparametric MRI pre- and post-DVE (right portal and hepatic vein). FLR volume, liver fibro-inflammation (corrected T1) scores and fat percentage (proton density fat fraction, PDFF) were determined. Patient metrics were compared by Wilcoxon signed-rank test and statistical analysis done using R software. RESULTS: All patients underwent uncomplicated DVE with improvement in liver remnant health, median 37 days after DVE: cT1 scores reduced from median (interquartile range) 790 ms (753-833 ms) to 741 ms (708-760 ms) p = 0.014 [healthy range <795 ms], as did PDFF from 11% (4-21%), to 3% (2-12%) p = 0.017 [healthy range <5.6%]. There was a significant increase in median (interquartile range) FLR volume from 33% (30-37%)% to 49% (44-52%), p = 0.002. CONCLUSION: This non-invasive and reproducible MRI technique showed improvement in volume and quality of the FLR after DVE. This is a significant advance in our understanding of how to prevent liver failure in patients undergoing major liver surgery.


Subject(s)
Embolization, Therapeutic , Liver Neoplasms , Multiparametric Magnetic Resonance Imaging , Predictive Value of Tests , Aged , Female , Humans , Male , Middle Aged , Hepatectomy , Hepatic Veins/diagnostic imaging , Liver/diagnostic imaging , Liver/pathology , Liver Neoplasms/therapy , Liver Neoplasms/diagnostic imaging , Liver Regeneration , Portal Vein/diagnostic imaging , Time Factors , Treatment Outcome
5.
Clin J Gastroenterol ; 17(3): 477-483, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38436842

ABSTRACT

A 53-year-old woman was diagnosed with liver dysfunction in August 20XX. Computed tomography (CT) revealed multiple hepatic AV shunts, and she was placed under observation. In March 20XX + 3, she developed back pain, and CT performed during an emergency hospital visit showed evidence of intrahepatic bile duct dilatation. She was referred to our gastroenterology department in May 20XX + 3. We conducted investigations on suspicion of hereditary hemorrhagic telangiectasia (HHT) with hepatic AV shunting based on contrast-enhanced CT performed at another hospital. HHT is generally discovered due to epistaxis, but there are also cases where it is diagnosed during examination of liver damage.


Subject(s)
Telangiectasia, Hereditary Hemorrhagic , Tomography, X-Ray Computed , Humans , Telangiectasia, Hereditary Hemorrhagic/complications , Telangiectasia, Hereditary Hemorrhagic/diagnostic imaging , Female , Middle Aged , Hepatic Veins/abnormalities , Hepatic Veins/diagnostic imaging , Arteriovenous Fistula/diagnostic imaging , Arteriovenous Fistula/complications , Hepatic Artery/diagnostic imaging , Hepatic Artery/abnormalities , Liver Diseases/etiology , Liver Diseases/diagnostic imaging
8.
Surg Radiol Anat ; 46(3): 377-379, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38280967

ABSTRACT

The widespread use of computed tomography (CT) for diagnosing and screening abdominal conditions often reveals rare, asymptomatic anomalies. There is a wide range of documented congenital variations in the anatomy of the inferior vena cava (IVC) and hepatic veins. In this report, we detail an exceptionally unusual variant of the IVC that follows a frontward and intraliver course, terminating at the anterior section of the right atrium. To gain a deeper insight into this anomaly, we employed 3D reconstruction techniques using the software Slicer and Blender.


Subject(s)
Imaging, Three-Dimensional , Vena Cava, Inferior , Humans , Vena Cava, Inferior/diagnostic imaging , Hepatic Veins/diagnostic imaging , Tomography, X-Ray Computed/methods , Anatomic Variation
9.
Transplant Proc ; 56(1): 125-134, 2024.
Article in English | MEDLINE | ID: mdl-38177046

ABSTRACT

BACKGROUND: Living-donor liver transplantation (LDLT) is established as a standard therapy for end-stage liver disease; however, vessel reconstruction is more demanding due to the short length and small size of the available structures compared with deceased-donor whole liver transplantation. Interventional radiology (IR) has become the first-line treatment for vascular complications after LDLT. Hepatic venous outflow obstruction (HVOO) is a life-threatening complication after LDLT. The aim of this study of 592 adult-to-adult LDLT cases was to investigate the safety and efficacy of stent implantation for HVOO after LDLT. METHODS: Records of patients who developed HVOO requiring any treatment were collected with special reference to the metallic stent implantation. There were 232 left-side grafts and 360 right-side grafts. Sixteen cases developed HVOO after LDLT with an incidence rate of 2.7%, 5 with a left liver graft (2%), and 11 with a right-side graft (3%). The IR was attempted for 14 cases; among those, 8 cases were treated by stent implantation. RESULTS: The technical success rate of the initial stent implantation was 100%. The pressure gradient at the stenotic site significantly improved from 12.2 (range, 10.9-20.4 cm H2O) to 3.9 cm H2O (range, 1.4-8.2 cm H2O; P = .03). The volume of the congested graft liver decreased significantly from 1448 (range, 788-2170 mL) to 1265 mL (range, 748-1665 mL; P = .01), and the serum albumin level improved significantly from 3.3 (range, 1.7-3.7 g/dL) to 3.7 g/dL (range, 2.9-4.1 g/dL; P = .02). No procedure-related complication was noted, and the long-term stent patency was 100%. CONCLUSION: Metallic stent implantation for stenotic venous anastomosis after LDLT is a safe and effective treatment.


Subject(s)
Budd-Chiari Syndrome , Liver Transplantation , Adult , Humans , Budd-Chiari Syndrome/diagnostic imaging , Budd-Chiari Syndrome/etiology , Budd-Chiari Syndrome/surgery , Liver Transplantation/adverse effects , Living Donors , Hepatic Veins/diagnostic imaging , Hepatic Veins/surgery , Treatment Outcome , Stents/adverse effects , Constriction, Pathologic/etiology
10.
J Anat ; 244(1): 133-141, 2024 01.
Article in English | MEDLINE | ID: mdl-37688452

ABSTRACT

Anatomical variations of the right hepatic vein, especially large variant right hepatic veins (≥5 mm), have important clinical implications in liver transplantation and resection. This study aimed to evaluate anatomical variations of the right hepatic vein using quantitative three-dimensional visualization analysis. Computed tomography images of 650 patients were retrospectively analyzed, and three-dimensional visualization was applied using the derived data to analyze large variant right hepatic veins. The proportion of the large variant right hepatic vein was 16.92% (110/650). According to the location and number of the variant right hepatic veins, the configuration of the right hepatic venous system was divided into seven subtypes. The length of the retrohepatic inferior vena cava had a positive correlation with the diameter of the right hepatic vein (rs = 0.266, p = 0.001) and the variant right hepatic veins (rs = 0.211, p = 0.027). The diameter of the right hepatic vein was positively correlated with that of the middle hepatic vein (rs = 0.361, p < 0.001), while it was inversely correlated with that of the variant right hepatic veins (rs = -0.267, p = 0.005). The right hepatic vein diameter was positively correlated with the drainage volume (rs = 0.489, p < 0.001), while the correlation with the variant right hepatic veins drainage volume was negative (rs = -0.460, p < 0.001). The number of the variant right hepatic veins and their relative diameters were positively correlated (p < 0.001). The volume and percentage of the drainage area of the right hepatic vein decreased significantly as the number of the variant right hepatic vein increased (p < 0.001). The findings of this study concerning the variations of the hepatic venous system may be useful for the surgical planning of liver resection or transplantation.


Subject(s)
Hepatic Veins , Liver Transplantation , Humans , Hepatic Veins/diagnostic imaging , Hepatic Veins/anatomy & histology , Hepatic Veins/surgery , Retrospective Studies , Vena Cava, Inferior/diagnostic imaging , Hepatectomy/methods
11.
J Nippon Med Sch ; 91(1): 119-123, 2024 Mar 09.
Article in English | MEDLINE | ID: mdl-37271547

ABSTRACT

A Japanese man in his 20s was referred to our hospital with a two-month history of abdominal fullness and leg edema. Abdominal computed tomography revealing massive ascites and ostial blockage of the main hepatic veins, and angiographic evaluation demonstrating obstruction of the main hepatic veins yielded a diagnosis of Budd-Chiari syndrome (BCS). Diuretic agents were prescribed for the ascites but failed to provide relief. The patient was referred to our department for further evaluation and treatment. Angiography showed ostial obstruction of the main hepatic veins, with most of the portal hepatic flow draining from an inferior right hepatic vein (IRHV) into the inferior vena cava (IVC) thorough an intrahepatic portal venous and venovenous shunt. Access between the main hepatic veins and IVC was impossible, but cannulation between the IRHV and IVC was achieved. Because of the venovenous connection between the main hepatic vein and the IRHV, metallic stents were placed into two IRHVs to decrease congestion in the hepatic venous outflow. After stent placement followed by balloon expansion, the gradient pressure between the hepatic vein and IVC improved remarkably. The ascites and lower leg edema improved postoperatively, and long-term stent patency (6 years) was achieved.


Subject(s)
Budd-Chiari Syndrome , Male , Humans , Budd-Chiari Syndrome/complications , Budd-Chiari Syndrome/diagnostic imaging , Budd-Chiari Syndrome/surgery , Hepatic Veins/diagnostic imaging , Hepatic Veins/surgery , Ascites/diagnostic imaging , Ascites/etiology , Ascites/therapy , Stents/adverse effects , Edema/complications
12.
Cardiovasc Intervent Radiol ; 46(12): 1703-1712, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37704862

ABSTRACT

PURPOSE: To compare safety, technical and clinical outcomes of double vein embolization (DVE) via a trans-jugular approach with liver venous deprivation (LVD) via a trans-hepatic approach. MATERIALS AND METHODS: A single-center retrospective analysis was conducted on patients undergoing simultaneous portal and hepatic veins embolization in view of a major hepatectomy (June 2019-November 2022). Hepatic vein embolization was performed either by transjugular plug (DVE) or by transhepatic plug followed by glue injection (LVD). Inclusion criteria were availability of pre-procedural CT scan, and availability of CT scans acquired 10 days and 25 days post-procedure. Comparative data included complication rate, fluoroscopy time, dose area product (DAP), Future Liver Remnant volume and function increase (FLR-V and FLR-F increase, respectively) and clinical outcomes. RESULTS: Thirty-six patients (n = 14 DVE; n = 22 LVD) were included. No baseline significant differences were observed among the two groups. One grade-3 complication (2.8%) was observed in the LVD group; one case of technical failure (2.8%) was observed in the DVE group. Fluoroscopy time and DAP were similar between DVE and LVD (29 ± 17.7 vs. 25 ± 8.2 min, p = 0.97; 105.1 ± 63.5 vs. 143.4 ± 79.5 Gy·cm2, p = 0.15). No differences arose at either time-point in FLR-V increase (46.7 ± 23.1% vs. 48.2 ± 28.2%, 52.9 ± 30.9% vs. 53.2 ± 29%, respectively, p = 0.9). FLR-F increase also did not differ significantly (62.8 ± 55.2 vs. 67.4 ± 57.5, p = 0.9). No differences in drop-out rate from surgery were observed. (28.6% vs. 27.3%, p = 0.93). One case of grade-B post-hepatectomy liver failure (2.8%) was observed in the LVD group. CONCLUSION: LVD via transhepatic approach and DVE via transjugular approach seem equally safe and effective. Level of Evidence Level 3, Retrospective Cohort Study.


Subject(s)
Embolization, Therapeutic , Liver Neoplasms , Humans , Retrospective Studies , Hepatic Veins/diagnostic imaging , Portal Vein , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Treatment Outcome , Liver/diagnostic imaging , Liver/surgery , Hepatectomy/methods , Embolization, Therapeutic/methods
13.
IEEE J Biomed Health Inform ; 27(10): 4878-4889, 2023 10.
Article in English | MEDLINE | ID: mdl-37585324

ABSTRACT

Accurate segmentation of the hepatic vein can improve the precision of liver disease diagnosis and treatment. Since the hepatic venous system is a small target and sparsely distributed, with various and diverse morphology, data labeling is difficult. Therefore, automatic hepatic vein segmentation is extremely challenging. We propose a lightweight contextual and morphological awareness network and design a novel morphology aware module based on attention mechanism and a 3D reconstruction module. The morphology aware module can obtain the slice similarity awareness mapping, which can enhance the continuous area of the hepatic veins in two adjacent slices through attention weighting. The 3D reconstruction module connects the 2D encoder and the 3D decoder to obtain the learning ability of 3D context with a very small amount of parameters. Compared with other SOTA methods, using the proposed method demonstrates an enhancement in the dice coefficient with few parameters on the two datasets. A small number of parameters can reduce hardware requirements and potentially have stronger generalization, which is an advantage in clinical deployment.


Subject(s)
Hepatic Veins , Image Processing, Computer-Assisted , Humans , Hepatic Veins/diagnostic imaging
14.
Liver Transpl ; 29(12): 1292-1303, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37540170

ABSTRACT

Hepatic venous outflow obstruction (HVOO) is a rare but critical vascular complication after adult living donor liver transplantation. We categorized HVOOs according to their morphology (anastomotic stenosis, kinking, and intrahepatic stenosis) and onset (early-onset < 3 mo vs. late-onset ≥ 3 mo). Overall, 16/324 (4.9%) patients developed HVOO between 2000 and 2020. Fifteen patients underwent interventional radiology. Of the 16 hepatic venous anastomoses within these 15 patients, 12 were anastomotic stenosis, 2 were kinking, and 2 were intrahepatic stenoses. All of the kinking and intrahepatic stenoses required stent placement, but most of the anastomotic stenoses (11/12, 92%) were successfully managed with balloon angioplasty, which avoided stent placement. Graft survival tended to be worse for patients with late-onset HVOO than early-onset HVOO (40% vs. 69.3% at 5 y, p = 0.162) despite successful interventional radiology. In conclusion, repeat balloon angioplasty can be considered for simple anastomotic stenosis, but stent placement is recommended for kinking or intrahepatic stenosis. Close follow-up is recommended in patients with late-onset HVOO even after successful treatment.


Subject(s)
Angioplasty, Balloon , Budd-Chiari Syndrome , Liver Transplantation , Humans , Adult , Budd-Chiari Syndrome/diagnostic imaging , Budd-Chiari Syndrome/etiology , Budd-Chiari Syndrome/therapy , Liver Transplantation/adverse effects , Constriction, Pathologic/etiology , Constriction, Pathologic/therapy , Living Donors , Treatment Outcome , Stents/adverse effects , Hepatic Veins/diagnostic imaging , Hepatic Veins/surgery , Angioplasty, Balloon/adverse effects
15.
J Gastrointest Surg ; 27(10): 2085-2091, 2023 10.
Article in English | MEDLINE | ID: mdl-37433951

ABSTRACT

BACKGROUND: Anatomic resection (AR) is a surgical method for treating hepatocellular carcinoma, and identifying intersegmental planes between segments 5 (S5) and 8 (S8) remains challenging. This study aims to find reliable intersegmental veins (IVs) between them as anatomical landmarks using 3D reconstruction analysis. METHODS: We retrospectively evaluated 57 patients who underwent multidetector-row CT scans from September 2021 to January 2023. The portal vein watershed of S5 and S8 and hepatic veins were reconstructed using 3D reconstruction analysis software. We counted and analyzed the IVs running within the intersegmental plane between S5 and S8, examined their features, and analyzed the location of the junctions between IVs and middle hepatic veins (MHVs). RESULTS: Among the 57 patients, 43 patients (75.4%) had IVs between S5 and S8. Most patients (81.4%) had a single IV joining the MHV, while 13.9% had two IVs, one joining the MHV and the other joining the right hepatic vein (RHV). The majority of IV-MHV junctions were found in the lower part of the MHVs. The most clearly identifiable junctions between the IVs and MHVs occurred slightly below the midpoint of the horizontal planes of the second hepatic portal and the center of the gallbladder bed. CONCLUSION: Our study identified IVs between S5 and S8 in the liver as potential anatomical landmarks during AR for hepatocellular carcinoma surgery. We found three types of IVs and provided insights on how to locate their junctions with MHVs for easier surgical navigation. However, individual anatomical variations must be considered, and preoperative 3D reconstruction and personalized surgical planning are crucial for success. More research with larger sample sizes is needed to validate our findings and establish the clinical significance of these IVs as landmarks for AR.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Humans , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/surgery , Imaging, Three-Dimensional , Retrospective Studies , Hepatectomy/methods , Hepatic Veins/diagnostic imaging , Hepatic Veins/surgery , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery
16.
J Am Heart Assoc ; 12(12): e029857, 2023 06 20.
Article in English | MEDLINE | ID: mdl-37301763

ABSTRACT

Background It has been reported that the hepatic vein waveforms determined by abdominal ultrasonography can assess hepatic congestion in patients with heart failure (HF). However, the parameter that quantifies hepatic vein waveforms has not been established. We suggest the hepatic venous stasis index (HVSI) as the novel indicator to evaluate hepatic congestion quantitatively. To examine the clinical significance of HVSI in patients with HF, we aimed to clarify the associations of HVSI with the parameters of cardiac function and right heart catheterization, as well as that with prognosis, in patients with HF. Methods and Results We performed abdominal ultrasonography, echocardiography, and right heart catheterization in patients with HF (n=513). The patients were divided into 3 groups based on HVSI as follows: HVSI 0 (HVSI=0, n=253), low HVSI (HVSI 0.01-0.20, n=132), and high HVSI (HVSI>0.20, n=128). We examined the associations of HVSI with parameters of cardiac function and right heart catheterization and followed up for cardiac events defined as cardiac death or worsening HF. There was a significant increase in level of B-type natriuretic peptide, inferior vena cava diameter, and mean right atrial pressure with increasing HVSI. During the follow-up period, cardiac events occurred in 87 patients. In the Kaplan-Meier analysis, cardiac event rate increased across increasing HVSI (log-rank, P=0.002). Conclusions HVSI assessed by abdominal ultrasonography reflects hepatic congestion and right-sided HF and is associated with adverse prognosis in patients with HF.


Subject(s)
Heart Failure , Liver Diseases , Vascular Diseases , Humans , Hepatic Veins/diagnostic imaging , Prognosis , Vascular Diseases/complications
17.
Liver Int ; 43(10): 2245-2255, 2023 10.
Article in English | MEDLINE | ID: mdl-37387503

ABSTRACT

BACKGROUND: Non-selective beta-blockers (NSBB) are widely used in the treatment of patients with cirrhosis. Only about 50% respond with a sufficient reduction in their hepatic venous pressure gradient (HVPG) and NSBB may induce detrimental cardiac and renal effects in the presence of severe decompensation. We aimed to assess the effects of NSBB on haemodynamics using magnetic resonance imaging (MRI) and to assess if these haemodynamic changes were related to the disease severity and HVPG response. METHOD: A prospective cross-over study of 39 patients with cirrhosis. Patients underwent hepatic vein catheterization and MRI with assessments of HVPG, cardiac function, systemic and splanchnic haemodynamics before and after propranolol infusion. RESULTS: Propranolol induced significant decreases in cardiac output (-12%) and blood flow of all vascular compartments, with the largest reductions seen in the azygos venous (-28%), portal venous (-21%), splenic (-19%) and superior mesenteric artery (-16%) blood flow. Renal artery blood flow fell by -5% in the total cohort, with a more pronounced reduction in patients without ascites than in those with ascites (-8% vs. -3%, p = .01). Twenty-four patients were NSBB responders. Their changes in HVPG after NSBB were not significantly associated with other haemodynamic changes. CONCLUSION: The changes in cardiac, systemic and splanchnic haemodynamics did not differ between NSBB responders and non-responders. The effects of acute NSBB blockade on renal flow seem to depend on the severity of the hyperdynamic state, with the largest reduction in renal blood flow in compensated patients compared to decompensated patients with cirrhosis. However, future studies are needed to assess the effects of NSBB on haemodynamics and renal blood flow in patients with diuretic-resistant ascites.


Subject(s)
Hypertension, Portal , Propranolol , Humans , Propranolol/pharmacology , Propranolol/therapeutic use , Cross-Over Studies , Hepatic Veins/diagnostic imaging , Ascites/diagnostic imaging , Ascites/drug therapy , Ascites/etiology , Prospective Studies , Hypertension, Portal/etiology , Hypertension, Portal/complications , Adrenergic beta-Antagonists/pharmacology , Adrenergic beta-Antagonists/therapeutic use , Liver Cirrhosis/diagnostic imaging , Liver Cirrhosis/drug therapy , Liver Cirrhosis/complications , Hemodynamics , Magnetic Resonance Imaging , Catheterization
18.
J Cardiothorac Vasc Anesth ; 37(8): 1456-1468, 2023 08.
Article in English | MEDLINE | ID: mdl-37183119

ABSTRACT

OBJECTIVE: Little is known about changes in portal, splenic, and hepatic vein flow patterns in children undergoing congenital heart surgery. This study aimed to determine the characteristics of portal, splenic, and hepatic vein flow patterns using ultrasonography in children undergoing cardiac surgery. DESIGN: Single-center, prospective observational study. SETTING: Tertiary children's hospital, operating room. PARTICIPANTS: Children undergoing cardiac surgery. MEASUREMENT AND MAIN RESULTS: The authors obtained ultrasound data from the heart, inferior vena cava, portal, splenic, and hepatic veins before and after surgeries. In the biventricular group, which included children with atrial and ventricular septal defects and pulmonary stenosis (n = 246), the portal pulsatility index decreased from 38.7% to 25.6% (p < 0.001) after surgery. The preoperative portal pulsatility index was significantly higher in patients with pulmonary hypertension (43.3% v 27.4%; p < 0.001). In the single-ventricle group (n = 77), maximum portal vein flow velocities of Fontan patients were significantly lower (13.5 cm/s) compared with that of patients with modified Blalock-Taussig shunt (19.7 cm/s; p = 0.035) or bidirectional cavopulmonary shunt (23.1 cm/s; p < 0.001). The cardiac index was inversely correlated with the portal pulsatility index in the bidirectional cavopulmonary shunt and Fontan circulation. (ß = -5.693, r2 = 0.473; p = 0.001) The portal pulsatility index was correlated with splenic venous pulsatility and hepatic venous atrial reverse flow velocity in biventricular and single-ventricle groups. CONCLUSIONS: The characteristics of venous Doppler patterns in the portal, splenic, and hepatic veins differed according to congenital heart disease. Further studies are required to determine the association between splanchnic venous Doppler findings and clinical outcomes in this population.


Subject(s)
Atrial Fibrillation , Fontan Procedure , Heart Defects, Congenital , Humans , Child , Hepatic Veins/diagnostic imaging , Vena Cava, Inferior/surgery , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Blood Flow Velocity
19.
BMC Gastroenterol ; 23(1): 144, 2023 May 10.
Article in English | MEDLINE | ID: mdl-37165348

ABSTRACT

BACKGROUND: The hemodynamics of patients with cirrhosis and portal hypertension are complex and variable. We aimed to investigate differences in venous pressures determined by innovative angiography and conventional angiography using balloon occlusion of the hepatic veins in patients with alcoholic cirrhosis and portal hypertension. METHODS: A total of 134 patients with alcoholic cirrhosis who fulfilled the inclusion criteria from June 2017 to June 2020 were included. During transjugular intrahepatic portosystemic shunt, conventional and innovative angiography were performed, and venous pressures were measured. A paired t-test and Pearson's correlation coefficient were used for analysis. RESULTS: Conventional and innovative hepatic angiography detected lateral branches of the hepatic vein in 26 (19.4%) and 65 (48.5%) cases, respectively (P < 0.001). Innovative angiography detected a total of 65 patients with lateral shunts, of whom 37 (56.9%) had initial shunts. The average wedged hepatic venous pressure and portal venous pressure of the initial lateral branches were 21.27 ± 6.66 and 35.84 ± 7.86 mmHg, respectively, with correlation and determination coefficients of 0.342 (P < 0.05) and 0.117, respectively. The mean hepatic venous pressure gradient and portal pressure gradient were 9.59 ± 7.64 and 26.86 ± 6.78 mmHg, respectively, with correlation and determination coefficients of 0.292 (P = 0.079) and 0.085, respectively. CONCLUSIONS: Innovative angiography reveals collateral branches of the hepatic veins more effectively than conventional angiography. Hepatic vein collateral branches are the primary factors leading to underestimation of wedged hepatic venous pressures and hepatic venous pressure gradients, with the initial hepatic vein collateral branches resulting in the most severe underestimations.


Subject(s)
Hepatic Veins , Hypertension, Portal , Humans , Hepatic Veins/diagnostic imaging , Liver Cirrhosis, Alcoholic , Hypertension, Portal/diagnostic imaging , Hypertension, Portal/etiology , Liver Cirrhosis/complications , Liver Cirrhosis/diagnostic imaging , Angiography , Portal Vein/diagnostic imaging
20.
J Pak Med Assoc ; 73(3): 684-686, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36932783

ABSTRACT

Anticoagulants are the first-line treatment option for patients with Budd-Chiari syndrome (BCS); however, intervention is required when this fails. Although, the ultimate treatment is liver transplant, other radiological procedures are for the management of the disease and bridge to definitive therapy. TIPS (trans jugular intrahepatic portosystemic shunt) is a method used by interventional radiologists to create a shunt between portal vein and hepatic vein. At times it is technically not possible, in such cases, direct intrahepatic portosystemic shunt (DIPS) is performed. This patient underwent a successful DIPS procedure for BCS along with balloon dilatation (venoplasty) for inferior vena cava (IVC) stenosis.


Subject(s)
Budd-Chiari Syndrome , Portasystemic Shunt, Transjugular Intrahepatic , Humans , Portasystemic Shunt, Transjugular Intrahepatic/methods , Developing Countries , Hepatic Veins/diagnostic imaging , Hepatic Veins/surgery , Budd-Chiari Syndrome/surgery , Treatment Outcome , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...