Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 11.889
Filter
1.
Sultan Qaboos Univ Med J ; 24(2): 186-193, 2024 May.
Article in English | MEDLINE | ID: mdl-38828253

ABSTRACT

Objectives: This study aimed to evaluate the outcomes of laparoscopic inguinal hernia repair (LIHR) regarding postoperative pain, recurrence rates, duration of hospital stay and other postoperative outcomes within the context of a tertiary care teaching hospital in South India, and the initial experience of laparoscopic repairs. The current consensus in the literature often suggests LIHR as superior to open inguinal hernia repair (OIHR). Methods: This single-centre, retrospective, observational study was conducted at the Jawaharlal Institute of Postgraduate Education and Research, Puducherry, India, from January 2011 to September 2020. All patients who underwent elective OIHR and LIHR were included. Data on the patients demographics, comorbidities, hernia type, mesh characteristics, surgery duration, hospital stay and immediate postoperative complications were collected and analysed. Results: A total of 2,690 OIHR and 158 LIHR cases were identified. The demographic profiles, hospital stay and complication rates were similar in both groups. However, surgical site infection was present exclusively in the OIHR group (3.55% versus 0.0%; P <0.05). The timeline for returning to normal activities was statistically shorter for the LIHR group (6 versus 8 days; P <0.05). The most frequent immediate complication in the LIHR group was subcutaneous emphysema (6.54% versus 0.0%; P <0.05). Recurrence (9.23% versus 3.61%; P = 0.09) and chronic pain (41.53% versus 13.55%; P <0.05) were higher in the LIHR group. Conclusion: Lower recurrence and chronic pain rates were observed with OIHR in the initial experience with LIHR in the hospital. However, LIHR had significant advantages concerning faster patient recovery and lower rates of surgical site infections. While the results contribute an interesting deviation from the standard narrative, they should be interpreted within the context of a learning curve associated with the early experience of the research team with LIHR.


Subject(s)
Hernia, Inguinal , Herniorrhaphy , Laparoscopy , Learning Curve , Length of Stay , Humans , Hernia, Inguinal/surgery , Laparoscopy/methods , Laparoscopy/statistics & numerical data , Laparoscopy/education , Male , Retrospective Studies , Female , Herniorrhaphy/methods , Herniorrhaphy/statistics & numerical data , Middle Aged , India , Adult , Length of Stay/statistics & numerical data , Treatment Outcome , Aged , Postoperative Complications/epidemiology , Pain, Postoperative
2.
J Gastrointest Surg ; 28(5): 731-737, 2024 May.
Article in English | MEDLINE | ID: mdl-38704207

ABSTRACT

BACKGROUND: Long-term medical and quality of life (QOL) outcomes in voluntary liver donors remain under investigated. The objective of the current study was to report long-term medical outcomes and re-evaluate QOL in living liver donors. METHODS: This was a single-center retrospective cohort study of donors who underwent donor hepatectomy between 2012 and 2018. We investigated long-term outcomes in 7 domains. These include medical problems, surgical procedures, work-related issues, pregnancy outcomes, psychiatric interventions, willingness to donate again, and long-term mortality. QOL was evaluated using short-form 36. RESULTS: The median follow-up time was 61.4 months (53.3-83.7). Among 698 donors, 80 (11.5%) experienced medical problems, 4 (0.6%) had work-related issues, and 20 (2.9%) needed psychiatric assistance. Surgery was performed in 49 donors (7%), and females were more likely to have undergone incisional hernia repair (5.8% vs 1.9%, P = .006). There were 79 postdonation pregnancies including 41 normal vaginal deliveries (51.9%), 35 cesarean sections (44.3%), and 3 miscarriages (3.8%). Willingness to donate again was reported by 658 donors (94.3%). Donors whose recipients were alive were more likely to donate again (95.5% vs 90.5%, P = .01). There were 3 deaths (0.4%) in the long-term. The mean physical composite score at initial and follow-up evaluation was 86.7 ± 13.9 and 76.5 ± 20.9 (P = .001), and the mean mental composite score at initial and follow-up evaluation was 92.1 ± 13.5 and 80.7 ± 16 (P = .001). CONCLUSION: The overall long-term outlook in living liver donors is promising. QOL parameters might deteriorate over time and frequent re-evaluation might be considered.


Subject(s)
Hepatectomy , Liver Transplantation , Living Donors , Quality of Life , Humans , Female , Male , Retrospective Studies , Adult , Living Donors/psychology , Hepatectomy/psychology , Liver Transplantation/psychology , Middle Aged , Pregnancy , Pregnancy Outcome , Follow-Up Studies , Time Factors , Young Adult , Herniorrhaphy
3.
Thorac Surg Clin ; 34(2): 163-170, 2024 May.
Article in English | MEDLINE | ID: mdl-38705664

ABSTRACT

Paraesophageal hernias are classified according to the altered anatomic relationships between the gastroesophageal junction or stomach and the diaphragmatic hiatus. Herniation of these structures into the mediastinum may produce common complaints such as reflux, chest pain, and dysphagia. The elective repair of these hernias is well tolerated and significantly improves quality of life among patients with symptomatic disease. The hallmarks of a quality repair include the circumferential mobilization of the esophagus to generate 3 cm of tension-free intra-abdominal length and the performance of a fundoplication.


Subject(s)
Hernia, Hiatal , Humans , Hernia, Hiatal/surgery , Hernia, Hiatal/complications , Herniorrhaphy/methods , Fundoplication/methods
4.
Thorac Surg Clin ; 34(2): 155-162, 2024 May.
Article in English | MEDLINE | ID: mdl-38705663

ABSTRACT

Bochdalek hernias are a rare occurrence in adults and usually asymptomatic, resulting in incidental discovery. However, surgical intervention is recommended for both symptomatic and asymptomatic Bochdalek hernias due to the risk of acute morbidity and mortality. There are various possible surgical approaches that may be appropriate depending on the circumstance, with robotic repair becoming increasingly popular. To date, the rarity of the condition has limited the available data on postoperative outcomes.


Subject(s)
Hernias, Diaphragmatic, Congenital , Herniorrhaphy , Humans , Hernias, Diaphragmatic, Congenital/surgery , Hernias, Diaphragmatic, Congenital/complications , Adult , Herniorrhaphy/methods
6.
Thorac Surg Clin ; 34(2): 147-154, 2024 May.
Article in English | MEDLINE | ID: mdl-38705662

ABSTRACT

Morgagni hernias may range from asymptomatic incidental findings to surgical emergencies. An abdominal approach is ideal in the majority of cases, although surgeons should understand alternatives for repair.


Subject(s)
Hernias, Diaphragmatic, Congenital , Humans , Hernias, Diaphragmatic, Congenital/surgery , Hernias, Diaphragmatic, Congenital/complications , Adult , Herniorrhaphy/methods , Tomography, X-Ray Computed
7.
Thorac Surg Clin ; 34(2): 133-145, 2024 May.
Article in English | MEDLINE | ID: mdl-38705661

ABSTRACT

Congenital diaphragmatic hernia (CDH) is a complex and highly variable disease process that should be treated at institutions with multidisciplinary teams designed for their care. Treatment in the neonatal period focuses on pulmonary hypoplasia, pulmonary hypertension, and cardiac dysfunction. Extracorporeal membrane oxygenation (ECMO) can be considered in patients refractory to medical management. Repair of CDH early during the ECMO course seems to improve mortality compared with other times for surgical intervention. The choice of surgical approach to CDH repair should consider the patient's physiologic status and the surgeon's familiarity with the operative approaches available, recognizing the pros/cons of each technique.


Subject(s)
Extracorporeal Membrane Oxygenation , Hernias, Diaphragmatic, Congenital , Humans , Infant , Infant, Newborn , Extracorporeal Membrane Oxygenation/methods , Hernias, Diaphragmatic, Congenital/surgery , Hernias, Diaphragmatic, Congenital/therapy , Herniorrhaphy/methods
8.
Am Surg ; 90(6): 1161-1166, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38751046

ABSTRACT

BACKGROUND: Blunt traumatic abdominal wall hernias (TAWHs) are rare but require a variety of operative techniques to repair including bone anchor fixation (BAF) when tissue tears off bony structures. This study aimed to provide a descriptive analysis of BAF technique for blunt TAWH repair. Bone anchor fixation and no BAF repairs were compared, hypothesizing increased hernia recurrence with BAF repair. METHODS: A secondary analysis of the WTA blunt TAWH multicenter study was performed including all patients who underwent repair of their TAWH. Patients with BAF were compared to those with no BAF with bivariate analyses. RESULTS: 176 patients underwent repair of their TAWH with 41 (23.3%) undergoing BAF. 26 (63.4%) patients had tissue fixed to bone, with 7 of those reinforced with mesh. The remaining 15 (36.6%) patients had bridging mesh anchored to bone. The BAF group had a similar age, sex, body mass index, and injury severity score compared to the no BAF group. The time to repair (1 vs 1 days, P = .158), rate of hernia recurrence (9.8% vs 12.7%, P = .786), and surgical site infection (SSI) (12.5% vs 15.6%, P = .823) were all similar between cohorts. CONCLUSIONS: This largest series to date found nearly one-quarter of TAWH repairs required BAF. Bone anchor fixation repairs had a similar rate of hernia recurrence and SSI compared to no BAF repairs, suggesting this is a reasonable option for repair of TAWH. However, future prospective studies are needed to compare specific BAF techniques and evaluate long-term outcomes including patient-centered outcomes such as pain and quality of life.


Subject(s)
Herniorrhaphy , Surgical Mesh , Wounds, Nonpenetrating , Humans , Male , Female , Wounds, Nonpenetrating/surgery , Herniorrhaphy/methods , Adult , Middle Aged , Abdominal Injuries/surgery , Suture Anchors , Recurrence , Retrospective Studies , Treatment Outcome , Hernia, Ventral/surgery , Hernia, Abdominal/surgery , Hernia, Abdominal/etiology , Injury Severity Score , Surgical Wound Infection/etiology , Surgical Wound Infection/epidemiology
10.
Asian J Endosc Surg ; 17(3): e13326, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38772576

ABSTRACT

Concurrent direct and indirect inguinal, femoral, and obturator hernias are rare. This case report describes a rare case treated using the laparoscopic approach. A 68-year-old female patient presented with a moving left inguinal lump and pain. Physical examination and abdominal computed tomography scan revealed the coexistence of a left inguinal hernia or Nuck canal hydrocele and a left femoral hernia. The patient underwent laparoscopic transabdominal preperitoneal repair, and all four orifices were covered with one mesh. The patient was discharged on the second postoperative day without any complications. The concurrent presence of four hernias on the same side is rare and has not been previously reported. The laparoscopic approach is useful in such cases because it allows visualization of multiple hernia orifices from the intra-abdominal cavity.


Subject(s)
Hernia, Femoral , Hernia, Inguinal , Hernia, Obturator , Herniorrhaphy , Laparoscopy , Humans , Female , Aged , Hernia, Obturator/surgery , Hernia, Obturator/complications , Hernia, Obturator/diagnostic imaging , Hernia, Femoral/surgery , Hernia, Femoral/complications , Hernia, Femoral/diagnosis , Herniorrhaphy/methods , Hernia, Inguinal/surgery , Hernia, Inguinal/complications , Surgical Mesh
11.
Langenbecks Arch Surg ; 409(1): 164, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38775920

ABSTRACT

PURPOSE: To explore the risk factors for incisional hernia (IH) recurrence following open prepertioneal repair. METHODS: Patients diagnosed with primary IH who underwent open preperitoneal repair at our hospital were enrolled. Patients were assessed, and perioperative factors were collected. Recurrence surveys were performed at regular intervals throughout the long-term postoperative follow-up. The risk factors for IH recurrence were identified using univariate and multivariate analyses. RESULTS: This study included 145 patients. Significant differences were found between recurrence and non-recurrence patients regarding pulmonary ventilation function (PVT), age, body mass index (BMI), mesh materials, type of surgery (clean, clean-contaminated, or contaminated), surgical site infections (SSIs), maximum width of the hernia defect (MWHD), and site of incisional hernia (P < 0.01). The univariate survival analysis revealed that PVT abnormalities, age > 70 years, BMI > 27 kg/m2, porcine small intestine submucosal (PSIS) mesh, non-clean surgery, SSIs, MWHD > 10 cm, and location in the lateral zones were significant factors for IH recurrence after open preperitoneal repair. The multivariate survival analysis showed that PVT abnormalities, age > 70 years, BMI > 27 kg/m2, and PSIS mesh were independent risk factors for IH recurrence after open preperitoneal repair. CONCLUSIONS: We identified PVT abnormalities, age > 70 years, BMI > 27 kg/m2, and PSIS mesh as novel risk factors for IH recurrence after open preperitoneal repair.


Subject(s)
Herniorrhaphy , Incisional Hernia , Recurrence , Surgical Mesh , Humans , Male , Female , Incisional Hernia/surgery , Incisional Hernia/etiology , Retrospective Studies , Risk Factors , Aged , Middle Aged , Herniorrhaphy/adverse effects , Herniorrhaphy/methods , Adult , Cohort Studies , Aged, 80 and over
12.
Khirurgiia (Mosk) ; (5): 86-94, 2024.
Article in Russian | MEDLINE | ID: mdl-38785243

ABSTRACT

OBJECTIVE: The purpose of the study was to evaluate the results of using fluoropolymer-coated mesh during intraperitoneal onlay mesh hernia repair in patients with primary ventral hernias. MATERIAL AND METHODS: The multicenter, non-randomized, controlled clinical study included 88 patients of both sexes who were operated on using a laparoscopic approach using the IPOM technique for a primary ventral hernia. The duration of observation ranged from 3 to 12 months. In the main group, 48 patients received fluoropolymer-coated meshes (Ftorex). A comparison was made with a retrospective group of 40 patients who were treated with anti-adhesive collagen-coated meshes (Parietene composite, Parietex Composite, Symbotex). RESULTS: The number of early and late postoperative complications in the groups did not have significant differences, at the same time, their number was lower in the group of patients in whom fluoropolymer-coated meshes were used. Most of the complications corresponded to Clavien-Dindo class I and II and did not pose a significant threat to health. There were no recurrences of hernias observed in patients included in the study. There were slightly more adhesions in the fluoropolymer-coated mesh group (35.4% vs. 25.0% in the collagen-coated mesh group). The quality of life of patients in the study groups did not differ. CONCLUSION: In laparoscopic IPOM hernia repair fluoropolymer-coated meshes are not inferior in effectiveness and safety to traditionally used collagen-coated meshes and can be recommended for use in patients with primary ventral hernias.


Subject(s)
Hernia, Ventral , Herniorrhaphy , Laparoscopy , Postoperative Complications , Surgical Mesh , Humans , Hernia, Ventral/surgery , Male , Female , Laparoscopy/methods , Middle Aged , Herniorrhaphy/methods , Herniorrhaphy/adverse effects , Herniorrhaphy/instrumentation , Postoperative Complications/prevention & control , Postoperative Complications/etiology , Tissue Adhesions/prevention & control , Adult , Coated Materials, Biocompatible , Treatment Outcome , Aged , Retrospective Studies , Fluorocarbon Polymers , Russia
13.
Sci Rep ; 14(1): 11786, 2024 05 23.
Article in English | MEDLINE | ID: mdl-38782992

ABSTRACT

Inguinal hernia repair is performed more than 20 million times per annum, representing a significant health and economic burden. Over the last three decades, significant technical advances have started to reduce the invasiveness of these surgeries, which translated to better recovery and reduced costs. Here we bring forward an innovative surgical technique using a biodegradable cyanoacrylate glue instead of a traumatic suture to close the peritoneum, which is a highly innervated tissue layer, at the end of endoscopy hernia surgery. To test how this affects the invasiveness of hernia surgery, we conducted a cohort study. A total of 183 patients that underwent minimally invasive hernia repair, and the peritoneum was closed with either a conventional traumatic suture (n = 126, 68.9%) or our innovative approach using glue (n = 57, 31.1%). The proportion of patients experiencing acute pain after surgery was significantly reduced (36.8 vs. 54.0%, p = 0.032) by using glue instead of a suture. In accordance, the mean pain level was higher in the suture group (VAS = 1.5 vs. 1.3, p = 0.029) and more patients were still using painkillers (77.9 vs. 52.4%, p = 0.023). Furthermore, the rate of complications was not increased in the glue group. Using multivariate regressions, we identified that using a traumatic suture was an independent predictor of acute postoperative pain (OR 2.0, 95% CI 1.1-3.9, p = 0.042). In conclusion, suture-less glue closure of the peritoneum is innovative, safe, less painful, and possibly leads to enhanced recovery and decreased health costs.


Subject(s)
Hernia, Inguinal , Herniorrhaphy , Laparoscopy , Pain, Postoperative , Peritoneum , Humans , Hernia, Inguinal/surgery , Pain, Postoperative/etiology , Male , Female , Laparoscopy/methods , Middle Aged , Peritoneum/surgery , Herniorrhaphy/methods , Herniorrhaphy/adverse effects , Aged , Sutures , Adult , Tissue Adhesives/therapeutic use , Suture Techniques , Cyanoacrylates/therapeutic use
14.
J Vis Exp ; (207)2024 May 03.
Article in English | MEDLINE | ID: mdl-38767385

ABSTRACT

Following a hiatal hernia repair, patients can present with recurrent or new symptoms. Symptoms can occur anywhere from weeks to years after surgery. These may include recurrent reflux, dysphagia, regurgitation, weight loss, or deteriorating quality of life. While nonoperative management can be pursued in some patients, reoperation may be the only option in select patients. A thorough preoperative workup, including a repeat esophagram, upper endoscopy, +/- chest computed tomography (CT) scan, manometry, pH probe, and/or gastric emptying study, is warranted to better understand the pathophysiology of the presenting symptoms. If a recurrent hernia, slipped, or migrated wrap is identified, surgery is considered. Pseudoachalasia must also be ruled out if obstructive symptoms are observed at the hiatus. Such an exhaustive workup is indeed necessary to ensure accurate diagnosis and optimal outcome. In addition, an understanding of the factors that may have led to the recurrence will increase the chances of a successful reoperation. Although a technically demanding procedure, redo hiatal hernia repair utilizing a minimally invasive approach is increasingly being employed with promising outcomes. Herein, the steps of a redo hiatal hernia repair via a minimally invasive approach will be outlined and detailed.


Subject(s)
Hernia, Hiatal , Hernia, Hiatal/surgery , Hernia, Hiatal/diagnostic imaging , Humans , Herniorrhaphy/methods , Reoperation/methods , Postoperative Complications/etiology , Recurrence
15.
ACS Appl Mater Interfaces ; 16(20): 25686-25697, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38739862

ABSTRACT

Polypropylene (PP) mesh is commonly used in repairing abdominal wall hernia (AWH). However, the use of synthetic prosthesis comes with the risk of developing a prosthetic infection, resulting in delayed healing, secondary surgery, and potentially increased mortality. To address these issues, a facile surface functionalization strategy for PP mesh based on phytic acid (PA) and polyhexamethylene guanidine (PHMG) was constructed through a one-step co-deposition process, referred to as the PA/PHMG coating. The development of PA/PHMG coating is mainly attributed to the surface affinity of PA and the electrostatic interactions between PA and PHMG. The PA/PHMG coating could be completed within 4 h under mild conditions. The prepared PA/PHMG coatings on PP mesh surfaces exhibited desirable biocompatibility toward mammalian cells and excellent antibacterial properties against the notorious "superbug" methicillin-resistant Staphylococcus aureus (MRSA) and tetracycline-resistant Escherichia coli (TRE). The PA/PHMG-coated PP meshes showed killing ratios of over 99% against MRSA in an infected abdominal wall hernia repair model. Furthermore, histological and immunohistochemical analysis revealed a significantly attenuated degree of neutrophil infiltration in the PA/PHMG coating group, attributed to the decreased bacterial numbers alleviating the inflammatory response at the implant sites. Meanwhile, the pristine PP and PA/PHMG-coated meshes showed effective tissue repair, with the PA/PHMG coating group exhibiting enhanced angiogenesis compared with pristine PP meshes, suggesting superior tissue restoration. Additionally, PP meshes with the highest PHMG weight ratio (PA/PHMG(3)) exhibited excellent long-term robustness under phosphate-buffered saline (PBS) immersion with a killing ratio against MRSA still exceeding 95% after 60 days of PBS immersion. The present work provides a facile and promising approach for developing antibacterial implants.


Subject(s)
Anti-Bacterial Agents , Methicillin-Resistant Staphylococcus aureus , Polypropylenes , Surgical Mesh , Polypropylenes/chemistry , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Methicillin-Resistant Staphylococcus aureus/drug effects , Animals , Escherichia coli/drug effects , Herniorrhaphy/instrumentation , Abdominal Wall/surgery , Abdominal Wall/pathology , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Mice , Hernia, Abdominal/surgery , Humans , Microbial Sensitivity Tests
16.
Sci Rep ; 14(1): 11523, 2024 05 21.
Article in English | MEDLINE | ID: mdl-38769410

ABSTRACT

Robotic-assisted treatment of ventral hernia offers many advantages, however, studies reported higher costs for robotic surgery compared to other surgical techniques. We aimed at comparing hospital costs in patients undergoing large ventral hernia repair with either robotic or open surgery. We searched from a prospectively maintained database patients who underwent robotic or open surgery for the treatment of the large ventral hernias from January 2016 to December 2022. The primary endpoint was to assess costs in both groups. For eligible patients, data was extracted and analyzed using a propensity score-matching. Sixty-seven patients were retrieved from our database. Thirty-four underwent robotic-assisted surgery and 33 open surgery. Mean age was 66.4 ± 4.1 years, 50% of patients were male. After a propensity score-matching, a similar total cost of EUR 18,297 ± 8,435 vs. 18,024 ± 7514 (p = 0.913) in robotic-assisted and open surgery groups was noted. Direct and indirect costs were similar in both groups. Robotic surgery showed higher operatory theatre-related costs (EUR 7532 ± 2,091 vs. 3351 ± 1872, p < 0.001), which were compensated by shorter hospital stay-related costs (EUR 4265 ± 4366 vs. 7373 ± 4698, p = 0.032). In the treatment of large ventral hernia, robotic surgery had higher operatory theatre-related costs, however, they were fully compensated by shorter hospital stays and resulting in similar total costs.


Subject(s)
Hernia, Ventral , Herniorrhaphy , Hospital Costs , Robotic Surgical Procedures , Humans , Male , Robotic Surgical Procedures/economics , Robotic Surgical Procedures/methods , Female , Hernia, Ventral/surgery , Hernia, Ventral/economics , Aged , Herniorrhaphy/economics , Herniorrhaphy/methods , Middle Aged , Length of Stay/economics , Propensity Score
17.
Pain Res Manag ; 2024: 3339753, 2024.
Article in English | MEDLINE | ID: mdl-38803624

ABSTRACT

Methods: 30 male patients with primary inguinal hernias undergoing primary inguinal herniorrhaphy were prospectively recruited for ilioinguinal nerve resection and evaluation. Three samples of the resected ilioinguinal nerve (proximal, canal, and distal) were evaluated using Masson's trichrome stain to measure fascicle and total nerve cross-sectional area and detect changes in collagen. Results: The fascicle cross-sectional area in the canal segment was significantly decreased compared to the proximal control with a large effect size observed (p = 0.016, η2 = 0.16). There was no significant difference in the nerve cross-sectional area between locations, but there was a moderate to large effect size observed between locations (p = 0.165, η2 = 0.105). There was no significant difference in collagen content nor effect size observed between locations (p = 0.99, η2 = 1.503 × 10-4). Interpretation. The decrease in the fascicle cross-sectional area within the inguinal canal further suggests that there is chronic pressure applied by hernia tissue consistent with axon degeneration. Collagen content is uniformly distributed along the length of the nerve. Further studies with larger samples are needed to confirm the observed effect of nerve location on the total nerve cross-sectional area and axon loss.


Subject(s)
Hernia, Inguinal , Herniorrhaphy , Inguinal Canal , Nerve Compression Syndromes , Humans , Male , Hernia, Inguinal/surgery , Middle Aged , Nerve Compression Syndromes/surgery , Inguinal Canal/innervation , Inguinal Canal/pathology , Inguinal Canal/surgery , Aged , Adult , Collagen/metabolism , Prospective Studies
18.
J Robot Surg ; 18(1): 228, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38809354

ABSTRACT

Emergency treatment of paraesophageal hernias can be carried out through laparotomy or minimally invasive approaches, however, evidence in this regard is weak. The aim of our study was to assess safety and feasibility of the robotic-assisted treatment of paraesophageal hernias in the emergency setting. At the Bellinzona e Valli Regional Hospital, Switzerland, we conducted a retrospective analysis of patients operated on from January 2020 to January 2024 with robotic surgery for emergency presentation of paraesophageal hernias. Demographic and clinical details, operative techniques, and postoperative outcomes were collected and analyzed. Out of 82 patients who underwent robotic-assisted paraesophageal hernia repair, 17 were treated in the emergency setting. Median age was 79 years (IQR 77-85), 3 (17.6%) patients were male, and median BMI was 23.9 kg/m2 (IQR 21.0-26.0). Most frequent presentation symptoms were pain (100%), regurgitation (88.2%), and dyspnea (17.6%). No intraoperative complication, conversion to open surgery or stomach resections were recorded. Two complications of grade 3 according to the Clavien-Dindo classification and one of grade 2 occurred; all were successfully treated until resolution. The median length of hospital stay was 8 days (IQR 5-16). After a mean follow-up of 15.9 months (IQR 6.5-25.6) only two small axial asymptomatic recurrences that required no treatment. Despite limitations, our study demonstrated a very low rate of intra- and postoperative complications, likely supporting the safety and feasibility of robotic-assisted treatment for paraesophageal hernias in emergency settings. Larger studies with a control arm are needed to validate our initial findings.


Subject(s)
Feasibility Studies , Hernia, Hiatal , Herniorrhaphy , Robotic Surgical Procedures , Humans , Hernia, Hiatal/surgery , Robotic Surgical Procedures/methods , Retrospective Studies , Aged , Male , Female , Aged, 80 and over , Herniorrhaphy/methods , Treatment Outcome , Length of Stay/statistics & numerical data , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Emergencies
19.
BMC Anesthesiol ; 24(1): 192, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38811911

ABSTRACT

BACKGROUND: The Erector spinae plane block (ESPB) reduces postoperative pain after several types of abdominal laparoscopic surgeries. There is sparse data on the effect of ESPB in laparoscopic ventral hernia repair. The purpose of this study was to test the postoperative analgesic efficacy of an ESPB for this procedure. METHODS: In this prospective, double-blind, randomized controlled study, adult patients undergoing laparoscopic ventral hernia repair were randomly assigned to either bilateral preoperative ESPB with catheters at the level of Th7 (2 × 30 ml of either 2.5 mg/ml ropivacaine or saline), with postoperative catheter top ups every 6 h for 24 h. The primary outcome was rescue opioid consumption during the first hour postoperatively. Secondary outcomes were total opioid consumption at 4 h and 24 h, pain scores, nausea, sedation, as well as Quality of Recovery 15 (QoR-15) and the EuroQol-5 Dimensions (EQ-5D-5L) during the first week. RESULTS: In total, 64 patients were included in the primary outcome measure. There was no significant difference in rescue opioid consumption (oral morphine equivalents (OME)) at one hour postoperatively, with the ESPB group 26.9 ± 17.1 mg versus 32.4 ± 24.3 mg (mean ± SD) in the placebo group (p= 0.27). There were no significant differences concerning the secondary outcomes during the seven-day observation period. Seven patients received a rescue block postoperatively, providing analgesia in five patients. CONCLUSION: We found no difference in measured outcomes between ESPB and placebo in laparoscopic ventral hernia repair. Future studies may evaluate whether a block performed using higher concentration and/or at a different thoracic level provides more analgesic efficacy. TRIAL REGISTRATION: NCT04438369 ; 18/06/2020. .


Subject(s)
Analgesics, Opioid , Hernia, Ventral , Herniorrhaphy , Laparoscopy , Nerve Block , Pain, Postoperative , Humans , Pain, Postoperative/prevention & control , Double-Blind Method , Female , Male , Laparoscopy/methods , Middle Aged , Nerve Block/methods , Prospective Studies , Hernia, Ventral/surgery , Herniorrhaphy/methods , Analgesics, Opioid/administration & dosage , Analgesics, Opioid/therapeutic use , Anesthetics, Local/administration & dosage , Ropivacaine/administration & dosage , Adult , Paraspinal Muscles/innervation , Aged
20.
Surg Laparosc Endosc Percutan Tech ; 34(3): 330-333, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38752657

ABSTRACT

BACKGROUND: Robotic ventral hernia repair has been increasing globally, with comparable outcomes to laparoscopic repair and lower rates of conversion to open surgery. Robotic surgery is increasing in popularity, and there is a number of new robotic systems entering the marketing. We report the first case of a Roboic eTEP using the Versius robotic system in a patient with an incisional hernia. METHODS: Surgery was performed using the Versius system from CMR surgical which consists of bedside units for each instrument and a console. The patient presented with an incisional hernia measuring 9.5×5 cm in the left flank. RESULTS: The patient was discharged on postoperative day (POD) 2 with a drain. There was no need for opioids. The drain was removed at POD 7. The patient presented at POD 10 with erythema and cellulitis in the area that previously had tape on it, and it was resolved with a short course of oral antibiotics. CONCLUSION: The eTEP technique for hernia surgery was safe and feasible using the Versius robotic system. Implementation is possible in experienced hands with minimal changes to the surgical techniques.


Subject(s)
Herniorrhaphy , Incisional Hernia , Robotic Surgical Procedures , Humans , Robotic Surgical Procedures/methods , Herniorrhaphy/methods , Herniorrhaphy/instrumentation , Incisional Hernia/surgery , Hernia, Ventral/surgery , Female , Middle Aged , Male , Abdominal Wall/surgery , Laparoscopy/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...