Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Publication year range
1.
Transplantation ; 80(9): 1269-74, 2005 Nov 15.
Article in English | MEDLINE | ID: mdl-16314795

ABSTRACT

BACKGROUND: Belzer solution is considered to be the best preservation media used for pancreas transplantation; however, its high cost accounts for approximately 14.5% of all resources allocated by the Brazilian government toward each pancreatic transplant. The objective of the present study was to test a reduction of Belzer solution during pancreas harvest, thereby lowering procedural cost. METHODS: The patients received pancreas-kidney transplantations during the period from January 2003 to August 2004. Patients were divided into two groups. Patients assigned to Group A (n=30) received only Belzer solution (2 L through the aorta artery), whereas patients in Group B (n=16) were perfused first with 1 L of Eurocollins solution followed by 1 L of Belzer solution. The two groups were assessed for differences in the following clinical parameters: the need for insulin replacement or antifungal and anticytomegalovirus treatment, pancreatitis, acute cellular rejection, graft vascular thrombosis, fistulas, intra-abdominal collection, graft loss, deaths, pancreatic ischemia time, and average hospitalization time. RESULTS: No statistically significant differences were observed in any of the parameters analyzed (P<0.05). The use of Eurocollins solution, followed by Belzer solution during pancreas harvesting, did not result in differences in graft survival or functionality, postsurgical complications, or patient survival and hospitalization time, when compared to the use of Belzer solution alone. CONCLUSIONS: Perfusion with 1 L of Eurocollins solution followed by 1 L of Belzer solution during pancreas harvesting seems to be a simple and efficient alternative for reducing the costs of the harvesting process.


Subject(s)
Aorta , Hypertonic Solutions/standards , Organ Preservation Solutions/standards , Pancreas , Tissue and Organ Harvesting , Adenosine/economics , Adult , Allopurinol/economics , Cost Control , Drug Costs , Female , Glutathione/economics , Humans , Insulin/economics , Length of Stay , Male , Organ Preservation Solutions/economics , Pancreas/physiopathology , Pancreas Transplantation/adverse effects , Raffinose/economics , Survival Analysis , Therapeutic Irrigation , Tissue Survival , Tissue and Organ Harvesting/economics , Tissue and Organ Harvesting/methods
2.
Thromb Res ; 107(5): 255-61, 2002 Sep 01.
Article in English | MEDLINE | ID: mdl-12479887

ABSTRACT

Resuscitation with hypertonic saline (HS) appears to aggravate bleeding in a model of uncontrolled hemorrhage [J. Trauma 28 (1988) 751; J. Trauma 29 (1989) 79; Arch. Surg. 127 (1992) 93]. This property may be related to the anticoagulant effects of HS on plasma clotting factors and platelets [J. Trauma 31 (1991) 8]. The hypothesis in this study is that a hypertonic solution can be developed that would not disturb the blood coagulation mechanism and could be used as an alternative to hypertonic saline.HS and four different 2400 mosM solutions containing monosaccharides and/or glycine were screened for their in vitro effects on plasma clotting times and platelets. Significant prolongations falling outside the normal range were detected in prothrombin time (PT) and thrombin rime (TT) when only 5% of the volume of normal plasma is HS. Platelet function as measured by extent of shape change (ESC) induced by ADP and aggregation induced by thrombin were also critically impaired by HS at a 5% dilution. All alternative solutions-hypertonic glucose, sorbitol, glycine, glucose/glycine, glucose/mannitol/glycine, sorbitol/glycine-caused a significantly reduced impairment in platelet function and the plasma coagulation system. Hypertonic glycine showed a unique ability to fully preserve the function and integrity of the plasma coagulation system. Considering the pre-deposition of the trauma patient to coagulopathy, administration of HS which clearly is a potent anticoagulant and anti-platelet risks further aggravating the coagulopathy. In contrast, hypertonic glycine preserves the blood coagulation mechanism and exhibits the potential for numerous therapeutic applications. Therefore, prompt evaluation of hypertonic glycine as a resuscitative fluid is highly desirable.


Subject(s)
Blood Coagulation/drug effects , Hypertonic Solutions/adverse effects , Blood Coagulation Tests , Blood Platelets/drug effects , Drug Evaluation , Glycine/pharmacology , Humans , Hypertonic Solutions/chemistry , Hypertonic Solutions/standards , Hypertonic Solutions/therapeutic use , Monosaccharides/pharmacology , Plasma/drug effects , Platelet Activation/drug effects , Platelet Function Tests
4.
Transplantation ; 57(5): 649-55, 1994 Mar 15.
Article in English | MEDLINE | ID: mdl-8140626

ABSTRACT

The aim of the study was to delineate the most optimal preservation conditions for small bowel grafts. Established preservation solutions such as EuroCollins, University of Wisconsin, histidine-tryptophane-ketoglutarate-Brettschneider, phosphate-buffered sucrose (PBS 140), and 3 new solutions--extracellular fluid (ECF), lactobionate fructose, and a modified lactobionate fructose solution--were compared with saline to determine the most optimal solution for the intestine. Recipient survival, standard histology, and glutaminase activity were used to assess the degree of injury encountered after 12 hr of preservation followed by transplantation. To evaluate the various preservation conditions, ECF was used at pH 6.8 (original ECF). Grafts were preserved most optimally when a vascular washout after the cold storage period was omitted and when topical rewarming of the graft with 37 degrees C saline before reperfusion was performed. Graft survival was not significantly different after preservation with any solution tested (50-83%). Highest graft survival (83%) was achieved with lactobionate fructose and PBS140. Histologic evaluation 20 min after reperfusion revealed minor differences between most groups; a slight advantage was observed for PBS140-preserved grafts. Mucosal glutaminase activity of PBS140-preserved grafts was significantly higher 20 min after reperfusion compared with any other solution evaluated, indicating a superior graft function. These data indicate that different preservation conditions have a great impact on postoperative graft survival and that PBS140 might be preferable to any of the other preservation solutions tested.


Subject(s)
Intestine, Small , Organ Preservation Solutions , Organ Preservation , Solutions/standards , Adenosine/standards , Allopurinol/standards , Animals , Cryopreservation , Evaluation Studies as Topic , Glutaminase/metabolism , Glutathione/standards , Graft Survival/physiology , Hypertonic Solutions/standards , Insulin/standards , Intestinal Mucosa/enzymology , Intestine, Small/anatomy & histology , Male , Organ Preservation/methods , Raffinose/standards , Rats , Rats, Inbred Lew , Time Factors
5.
HPB Surg ; 4(4): 313-20, 1991.
Article in English | MEDLINE | ID: mdl-1810373

ABSTRACT

To compare UW-solution (UW) and Euro-Collins (EC) for long-term liver preservation we investigated the morphology and metabolic capacity of rat liver after 18 and 42-hours cold-storage in either UW or EC. After harvesting the rat liver was transferred to a perfusion chamber where it was perfused for 10 min with UW or EC at 4 degrees C. Thereafter livers were stored at 4 degrees C in UW or EC for 18 hours (both groups n = 6) or for 42 hours (both groups n = 8). After 18-hr or 42-hr cold-storage a 2-hr warm perfusion (37 degrees C) was started with Krebs-Ringer solution with carbogen to which 125Iodine-triiodothyronine (T3) was added. Control livers (n = 8) were immediately perfused with Krebs-Ringer without cold-storage. The following parameters were assessed: ASAT-levels in the perfusate, T3-metabolites in the bile and the perfusate, the perfusion pressure, the volume of bile secreted and light-microscopical morphology at the end of the warm perfusion period. After cold storage in UW-solution the ASAT-levels in the perfusate were lower than after storage in EC as well as the perfusion pressures. These livers demonstrated a better T3-metabolism and secreted more bile than EC-stored livers. Histological examination showed more tissue damage in the EC-stored livers than in the UW stored livers. We conclude that cold-storage of rat liver in UW-solution resulted in a better morphology and metabolic capacity as compared with EC-solution.


Subject(s)
Hypertonic Solutions/standards , Liver/anatomy & histology , Organ Preservation Solutions , Reperfusion , Solutions/standards , Tissue Preservation/standards , Adenosine , Allopurinol , Animals , Aspartate Aminotransferases/metabolism , Bile/metabolism , Drug Evaluation, Preclinical , Glutathione , Insulin , Liver/metabolism , Male , Raffinose , Rats , Rats, Inbred Strains , Tissue Preservation/methods , Triiodothyronine/metabolism , Triiodothyronine/pharmacokinetics
SELECTION OF CITATIONS
SEARCH DETAIL
...