Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 797
Filter
1.
Langenbecks Arch Surg ; 409(1): 135, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38649506

ABSTRACT

OBJECTIVE: Endovascular repair is the preferred treatment for aortoiliac aneurysm, with preservation of at least one internal iliac artery recommended. This study aimed to assess pre-endovascular repair anatomical characteristics of aortoiliac aneurysm in patients from the Global Iliac Branch Study (GIBS, NCT05607277) to enhance selection criteria for iliac branch devices (IBD) and improve long-term outcomes. METHODS: Pre-treatment CT scans of 297 GIBS patients undergoing endovascular aneurysm repair were analyzed. Measurements included total iliac artery length, common iliac artery length, tortuosity index, common iliac artery splay angle, internal iliac artery stenosis, calcification score, and diameters in the device's landing zone. Statistical tests assessed differences in anatomical measurements and IBD-mediated internal iliac artery preservation. RESULTS: Left total iliac artery length was shorter than right (6.7 mm, P = .0019); right common iliac artery less tortuous (P = .0145). Males exhibited greater tortuosity in the left total iliac artery (P = .0475) and larger diameter in left internal iliac artery's landing zone (P = .0453). Preservation was more common on right (158 unilateral, 34 bilateral) than left (105 unilateral, 34 bilateral). There were 192 right-sided and 139 left-sided IBDs, with 318 IBDs in males and 13 in females. CONCLUSION: This study provides comprehensive pre-treatment iliac anatomy analysis in patients undergoing endovascular repair with IBDs, highlighting differences between sides and sexes. These findings could refine patient selection for IBD placement, potentially enhancing outcomes in aortoiliac aneurysm treatment. However, the limited number of females in the study underscores the need for further research to generalize findings across genders.


Subject(s)
Endovascular Procedures , Iliac Aneurysm , Humans , Male , Female , Iliac Aneurysm/surgery , Iliac Aneurysm/diagnostic imaging , Aged , Endovascular Procedures/methods , Middle Aged , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/pathology , Iliac Artery/diagnostic imaging , Blood Vessel Prosthesis Implantation/methods , Aged, 80 and over , Tomography, X-Ray Computed , Treatment Outcome
2.
J Vasc Surg ; 79(6): 1369-1378, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38316346

ABSTRACT

OBJECTIVE: There are a variety of methods used today to treat common iliac aneurysms with endovascular techniques. Of these approaches, little is known about whether a particular limb strategy influences endoleak, reintervention, or aneurysm regression rates. We present 5-year data comparing endoleak, stent graft migration, fracture, aneurysm sac dynamics, and aortic rupture rates among patients treated with bell bottom limbs (BB), iliac branch endoprosthesis (IBE), and coil and cover (CC) approaches from the Global Registry for Endovascular Aortic Treatment registry. Secondary end points were all-cause mortality, stroke, reintervention, and paraplegia. METHODS: Subjects from the GORE Global Registry for Endovascular Aortic Treatment were enrolled over a 5-year period from October 2017 to August 2022. We included 924 subjects in this study. Statistical data was generated on R software and limb groups were compared using the Pearson's χ2 test and the Kruskal-Wallis rank-sum test. RESULTS: We found no statistical difference in endoleak rates, stent graft migration, fracture, or aortic rupture when stratified by limb strategy. There was no difference between limb approaches with regard to aneurysm sac dynamics among those with abdominal aortic aneurysms and common iliac aneurysms. Similarly, no statistical difference between limb strategies was found in all-cause mortality, stroke, paraplegia, or reintervention rates. Among patients that required an additional graft during reintervention, the highest rates were found within the IBE group 8.6%, compared with BB group 2.2% and CC group 1.3% (P = .006). CONCLUSIONS: Overall, there was no difference among limb strategies in endoleak rates, stent graft migration, aneurysm sac dynamics, aortic rupture rates, or our secondary end points. Increased rates of reintervention requiring an additional graft within the IBE group is noteworthy and must be weighed against the adverse effects of hypogastric sacrifice with the CC approach or potentially less advantageous seal zones in the BB approach. This finding suggests that all limb approaches have equivalent effectiveness in managing the aneurysmal common iliac artery; thus, the choice of limb strategy should be individualized and remain at physician discretion. Future research should include a more robust sample size to reproduce these findings.


Subject(s)
Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Iliac Aneurysm , Prosthesis Design , Registries , Stents , Humans , Iliac Aneurysm/surgery , Iliac Aneurysm/mortality , Iliac Aneurysm/diagnostic imaging , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Male , Female , Treatment Outcome , Time Factors , Aged , Risk Factors , Endoleak/etiology , Endoleak/surgery , Aged, 80 and over , Aortic Rupture/surgery , Aortic Rupture/mortality , Aortic Rupture/diagnostic imaging , Prosthesis Failure , Retrospective Studies , Risk Assessment , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/mortality , Aortic Aneurysm, Abdominal/diagnostic imaging , Foreign-Body Migration/etiology
4.
J Vasc Surg ; 79(6): 1379-1389, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38280686

ABSTRACT

OBJECTIVE: Infected native aneurysms (INAs) of the abdominal aorta and iliac arteries are uncommon, but potentially fatal. Endovascular aneurysm repair (EVAR) has recently been introduced as a durable treatment option, with outcomes comparable to those yielded by conventional open repair. However, owing to the rarity of the disease, the strengths and limitations of each treatment remain uncertain. The present study aimed to separately assess post-open repair and post-EVAR outcomes and to clarify factors affecting the short-term and late prognosis after each treatment. METHODS: Using a nationwide clinical registry, we investigated 600 patients treated with open repair and 226 patients treated with EVAR for INAs of the abdominal aorta and/or common iliac artery. The relationships between preoperative or operative factors and postoperative outcomes, including 90-day and 3-year mortality and persistent or recurrent aneurysm-related infection, were examined. RESULTS: Prosthetic grafts were used in >90% of patients treated with open repair, and in situ and extra-anatomic arterial reconstruction was performed in 539 and 57 patients, respectively. Preoperative anemia and imaging findings suggestive of aneurysm-enteric fistula were independently associated with poor outcomes in terms of both 3-year mortality (hazard ratio [HR], 1.62; 95% confidence interval [CI], 1.01-2.62; P = .046, and HR, 2.24; 95% CI, 1.12-4.46; P = .022, respectively) and persistent or recurrent infection (odds ratio [OR], 2.16; 95% CI, 1.04-4.49; P = .039, and OR, 4.96; 95% CI, 1.81-13.55; P = .002, respectively) after open repair, whereas omental wrapping or packing and antibiotic impregnation of the prosthetic graft for in situ reconstruction contributed to improved 3-year survival (HR, 0.60; 95% CI, 0.39-0.92; P = .019, and HR, 0.53; 95% CI, 0.32-0.88; P = .014, respectively). Among patients treated with EVAR, abscess formation adjacent to the aneurysm was significantly associated with the occurrence of persistent or recurrent infection (OR, 2.24; 95% CI, 1.06-4.72; P = .034), whereas an elevated preoperative white blood cell count was predictive of 3-year mortality (HR, 1.77; 95% CI, 1.00-3.13; P = .048). CONCLUSIONS: Profiles of prognostic factors differed between open repair and EVAR in the treatment of INAs of the abdominal aorta and common iliac artery. Open repair may be more suitable than EVAR for patients with concurrent abscess formation.


Subject(s)
Aneurysm, Infected , Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Registries , Humans , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Endovascular Procedures/instrumentation , Male , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/mortality , Aortic Aneurysm, Abdominal/diagnostic imaging , Female , Aged , Iliac Aneurysm/surgery , Iliac Aneurysm/mortality , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/microbiology , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Blood Vessel Prosthesis Implantation/instrumentation , Aneurysm, Infected/surgery , Aneurysm, Infected/microbiology , Aneurysm, Infected/mortality , Aneurysm, Infected/diagnostic imaging , Treatment Outcome , Risk Factors , Time Factors , Retrospective Studies , Aged, 80 and over , Middle Aged , Blood Vessel Prosthesis/adverse effects , Prosthesis-Related Infections/surgery , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/mortality , Prosthesis-Related Infections/diagnosis , Recurrence , Risk Assessment
7.
Cardiovasc Eng Technol ; 15(2): 199-210, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38110763

ABSTRACT

PURPOSE: Inappropriate stent-graft (SG) flexibility has been frequently associated with endovascular aortic repair (EVAR) complications such as endoleaks, kinks, and SG migration, especially in tortuous arteries. Stents derived from auxetic unit cells have shown some potential to address these issues as they offer an optimum trade-off between radial stiffness and bending flexibility. METHODS: In this study, we utilized an established finite element (FE)-based approach to replicate the mechanical response of a SG iliac limb derived from auxetic unit cells in a virtual tortuous iliac aneurysm using a combination of a 180° U-bend and intraluminal pressurization. This study aimed to compare the mechanical performance (flexibility and durability) of SG limbs derived from auxetic unit cells and two commercial SG limbs (Z-stented SG and circular-stented SG models) in a virtual tortuous iliac aneurysm. Maximal graft strain and maximum stress in stents were employed as criteria to estimate the durability of SGs, whereas the maximal luminal reduction rate and the bending stiffness were used to assess the flexibility of the SGs. RESULTS: SG limbs derived from auxetic unit cells demonstrated low luminal reduction (range 4-12%) with no kink, in contrast to Z-stented SG, which had a kink in its central area alongside a high luminal reduction (44%). CONCLUSIONS: SG limbs derived from auxetic unit cells show great promise for EVAR applications even at high angulations such as 180°, with acceptable levels of durability and flexibility.


Subject(s)
Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Finite Element Analysis , Models, Cardiovascular , Prosthesis Design , Stents , Stress, Mechanical , Humans , Endovascular Procedures/instrumentation , Blood Vessel Prosthesis Implantation/instrumentation , Iliac Aneurysm/surgery , Iliac Aneurysm/physiopathology , Iliac Aneurysm/diagnostic imaging , Materials Testing , Prosthesis Failure , Pliability , Computer Simulation
8.
Vasc Endovascular Surg ; 57(8): 923-926, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37300707

ABSTRACT

Surgical repair of a common iliac artery aneurysm (CIA) after previous open aortic reconstruction is associated with significant morbidity and mortality. Endovascular repair is considered less invasive than surgery. However, if preservation of the internal iliac artery (IIA) is required, the applicability of endovascular techniques may represent a challenge and a limitation to the use of standard aortic endografts or iliac branch devices. In these cases, the off-label use of endovascular devices may be an effective alternative. Herein, we report a successful hybrid approach to treat CIA using a reversed iliac limb endograft coupled with a double-barrel technique with femoro-femoral crossover bypass in a patient who had previously undergone open aortic reconstruction.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Humans , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/surgery , Blood Vessel Prosthesis , Treatment Outcome , Stents , Iliac Artery/diagnostic imaging , Iliac Artery/surgery , Aorta, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Prosthesis Design
9.
Ann Vasc Surg ; 96: 59-70, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37263413

ABSTRACT

BACKGROUND: To analyze clinical outcomes and perform a macro-costing evaluation of endovascular aortic repair (EVAR) for aorto-iliac aneurysms. METHODS: This is a retrospective, financially unsupported, physician-initiated observational cohort study. Patients with iliac artery involvement treated with EVAR between January 1st, 2014 and December 31st, 2021 were identified. Inclusion criteria were intact aneurysm, elective EVAR with at least 1 hypogastric artery (HA) treatment, use of bifurcated endograft (EG), and at least 6 months of follow-up. Primary outcomes of interest were overall survival, freedom from aneurysm-related mortality (ARM), freedom from EVAR-related reintervention, and overall EVAR(procedure)-related costs. RESULTS: We studied 122 (9.1%) patients: 119 (97.5%) were male and 3 (2.5%) females. Median age of patients was 76 years (range, 68.75-81). Overall, 107 (87.7%) patients had both HAs preserved according to following strategy: 45 (36.9%) with flared limbs, 13 (10.6%) with bilateral branched device, and 49 (40.2%) with a combination of flared limb on 1 side and branched device on the contralateral side. Bilateral overstenting was performed in 15 (12.3%) patients. Estimated overall survival was not different between groups of EVAR (Log-rank, P = 0.561). There was only 1 (0.8%) ARM ascertained during the follow-up. Estimated freedom from EVAR-related reintervention was not different among groups (Log-rank, P = 0.464). During the follow-up, 9 (7.4%) patients developed buttock claudication (Society for Vascular Surgery (SVS) grade 1, n = 4, SVS grade 2, n = 5), more frequently in HA overstenting (hazard ratio (HR): 3.6; 95% confidence intervals (CIs): 0.96-13.5, P = 0.058). When all cots were included, branched EVAR still carried the highest burden (P = 0.001) in comparison with the mixed subgroup, the overstenting subgroup, and the flared limbs subgroup. CONCLUSIONS: Early mortality and pelvic ischemic syndromes rate were acceptably low in all techniques. Hypogastric artery preservation showed lower complication rate in comparison with HA overstenting which, however, appears to be safe an effective for option with similar overall costs for patients who are not candidates for HA preservation based on aortic anatomy.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Female , Humans , Male , Aged , Aged, 80 and over , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/surgery , Iliac Artery , Endovascular Aneurysm Repair , Retrospective Studies , Treatment Outcome , Aorta, Abdominal , Endovascular Procedures/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis
10.
Ann Vasc Surg ; 97: 49-58, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37121339

ABSTRACT

BACKGROUND: Infected aortic and iliac artery aneurysms are challenging to treat. Cryopreserved arterial allografts (CAAs) or rifampin-soaked Dacron (RSD) are standard options for in situ reconstruction. Our aim was to compare the safety and effectiveness of CAA versus RSD for these complex pathologies. METHODS: This is a retrospective review of infected iliac, abdominal, and thoracoabdominal aortic aneurysms treated with either CAAs or RSD between 2002 and 2022 at our institution. The diagnosis was confirmed by intraoperative, radiologic, or microbiological evidence of aortic infection. Perioperative events, 30-day and long-term mortality, reinfection, and reintervention were analyzed. RESULTS: Thirty patients (17 CAA, 13 RSD) with a mean age of 61 and 68 years, respectively, were identified. The infected aneurysm was most commonly suprarenal or infrarenal. Culture-negative infections were present in 47% of the CAA group and 54% in the RSD group. Early major morbidity was 57% and 54% for the CAA and RSD, respectively. Thirty-day mortality was similar between groups (18% vs. 23% CAA vs. RSD, P ≥ 0.99). Median follow-up was longer in the RSD group (14.5 months vs. 13 months). Overall survival at 1 and 5 years was 80.8% and 64.8% in the CAA group and 69.2% and 57.7% in the RSD group. Reinterventions only occurred with CAA repairs and indications included graft occlusion (2), multiple pseudoaneurysms and reinfection (1), and hemorrhagic shock caused by graft rupture (1). Freedom from reintervention at 1 and 3 years was 87.5% and 79.5% (CAA group) versus 100% and 100% (RSD, P = 0.06). Freedom from reinfection at 1 year was 100% in both groups, while at 3 years it was 90.9% for the CAA group and 100% for the RSD group (P = 0.39). CONCLUSIONS: Infected aortic and iliac aneurysms have high early morbidity and mortality. CAA and RSD had similar outcomes in our series; CAA trended toward higher reintervention rates. Both remain viable options for complex scenarios but require close surveillance.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Iliac Aneurysm , Humans , Middle Aged , Aged , Rifampin/adverse effects , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/surgery , Polyethylene Terephthalates , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Reinfection , Treatment Outcome , Risk Factors , Allografts/surgery , Retrospective Studies , Aortic Aneurysm, Abdominal/surgery
11.
Ann Vasc Surg ; 94: 323-330, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36906129

ABSTRACT

BACKGROUND: Iliac artery tortuosity is an important anatomical factor that influences the endovascular repair of aortic artery aneurysms. The influencing factors of the iliac artery tortuosity index (TI) have not been well studied. TI of iliac arteries and related factors in Chinese patients with and without abdominal aortic aneurysm (AAA) were studied in this study. METHODS: One hundred and ten consecutive patients with AAA and 59 patients without AAA were included. For patients with AAA, the diameter of the AAA was 51.9 ± 13.3 mm (24.7-92.9 mm). Those without AAA had no history of definite arterial diseases and came from a cohort of patients diagnosed with urinary calculi. The central lines of the common iliac artery (CIA) and external iliac artery were depicted. The actual length and the straight distance were measured and used to calculate the TI (actual length/straight distance). Common demographic factors and anatomical parameters were analyzed to identify any related influencing factors. RESULTS: For patients without AAA, the total TI of the left and right side was 1.16 ± 0.14 and 1.16 ± 0.13, respectively (P = 0.48). For patients with AAAs, the total TI in the left and right side was 1.36 ± 0.21 and 1.36 ± 0.19, respectively (P = 0.87). The TI in external iliac artery was more severe than that in CIA both in patients with and without AAAs (P < 0.01). Age was the only demographic factor found to be associated with TI in patients with AAA (Pearson's correlation coefficient r ≈ 0.3, P < 0.01) and without AAA (r ≈ 0.6, P < 0.01). For anatomical parameters, the diameter was positively associated with the total TI (left side: r = 0.41, P < 0.01; right side: r = 0.34, P < 0.01). The ipsilateral CIA diameter was also associated with the TI (left side: r = 0.37, P < 0.01; right side: r = 0.31, P < 0.01). The length of the iliac arteries was not associated with age or AAA diameter. Reduction of the vertical distance of the iliac arteries may be a common underlying reason for age and AAA. CONCLUSIONS: Tortuosity of the iliac arteries was probably an age-related problem in normal individuals. It was also positively correlated with the diameter of the AAA and the ipsilateral CIA in patients with AAA. Attention should be paid to the evolution of iliac artery tortuosity and its influence when treating AAAs.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Iliac Aneurysm , Humans , Iliac Artery/diagnostic imaging , Iliac Artery/surgery , East Asian People , Treatment Outcome , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Retrospective Studies , Blood Vessel Prosthesis , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/surgery , Iliac Aneurysm/complications
12.
Ann Vasc Surg ; 94: 331-340, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36921795

ABSTRACT

BACKGROUND: The aim of study was to assess the safety and effectiveness of 3 different commercial iliac branch devices (IBDs): the Zenith Branch Iliac Endovascular Graft; the Gore Excluder Iliac Branch System and the E-liac Stent Graft System for the treatment of aorto-iliac or iliac aneurysms. METHODS: From January 2017 to February 2020, a retrospective reviewed was conducted on a total of 96 patients. Primary endpoint was IBD instability rate at 24 months. Secondary endpoints included onset of any endoleaks, buttock claudication, IBD-related reintervention and all-death rates, postoperative acute kidney, and changes in maximum diameter from baseline of the aortic aneurysmal sac. RESULTS: At 24 months, the branch instability rate was similar among the 3 IBDs employed [Jotec 1/24 (4.1%), Gore 1/12 (8.3%), Cook 6/47 (12.7%), P-value = 0.502]. As well, no statistical difference in terms of branch occlusion and branch-related endoleaks was observed. The Jotec group showed a significant decrease in maximum diameter from the baseline of the aortic aneurysmal sac when compared to the Gore group alone. No other differences were found relevant to the onset of any endoleaks, reinterventions, and all-death rates. At 24 months, the Kaplan-Meier estimate of survival freedom from any branch instability was 95.8%, 91.6%, and 86.8% for Jotec, Gore and Cook groups, respectively. CONCLUSIONS: The use of IBDs represents a safe method for preserving patency of the IIA during treatment of aorto-iliac or iliac aneurysms providing a low rate of IBD instability.


Subject(s)
Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Humans , Blood Vessel Prosthesis , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/surgery , Stents , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Retrospective Studies , Treatment Outcome , Time Factors , Prosthesis Design
14.
Medicine (Baltimore) ; 102(2): e32640, 2023 Jan 13.
Article in English | MEDLINE | ID: mdl-36637963

ABSTRACT

INTRODUCTION: Current bifurcated aortic endografts are unsuitable for patients with a narrow distal aorta except AFX2, which is unavailable in South Korea. An iliac branch device (IBD) was introduced to exclude iliac aneurysms while preserving the pelvic circulation. With advancements in endovascular techniques, various attempts for outside instructions for use have been reported to be practicable in certain patients. PATIENT CONCERNS: A 58-year-old man was referred to our emergency room with an incidentally found left common iliac artery aneurysm (CIAA) in a general checkup. DIAGNOSES: Computed tomography angiogram showed a narrow distal aorta that tapered from 20 mm just below the renal artery to 13 mm at aortic bifurcation and a left isolated CIAA with a maximal diameter of 40 mm and 70 mm in length. INTERVENTIONS: After left hypogastric artery embolization, the Cook IBD was placed at the aortic bifurcation, and the Bard Covera Plus stent-graft was deployed from the IBD cuff to the left external iliac artery. Then, a reversed Medtronic Endurant iliac limb was implanted into the infrarenal aorta down to the proximal IBD. OUTCOMES: The stent grafts were patent without endoleak at the 6-month follow-up. LESSONS: In selected patients with an isolated CIAA with a narrow distal aorta, IBD can be used as a main body at the aortic bifurcation for successful aneurysm exclusion. However, considering the application of outside instructions for use, special attention and careful planning must be taken before the procedure.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Male , Humans , Middle Aged , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/surgery , Blood Vessel Prosthesis , Iliac Artery/surgery , Blood Vessel Prosthesis Implantation/methods , Stents , Off-Label Use , Risk Factors , Treatment Outcome , Aorta, Abdominal , Endovascular Procedures/methods , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery
15.
Cardiovasc Intervent Radiol ; 46(2): 187-193, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36624291

ABSTRACT

PURPOSE: Iliac branch devices (IBD) are widely used to treat aortoiliac aneurysms with an unfit distal landing zone for standard endovascular aneurysm repair (EVAR). The aim of this retrospective study was to examine the treatment of aortoiliac aneurysms with the combination of the Endurant II(s) stent graft system (Medtronic®) and the E-liac stent graft (Artivion®). MATERIALS AND METHODS: Data of all patients who underwent an EVAR combined with unilateral or bilateral IBD between January 2015 and January 2020 were analyzed. Primary outcomes were technical success at implantation (successful EVAR with IBD extension placement and patency of the grafts without type 1 or type 3 endoleak), and type 1b/3 endoleak, hypogastric artery patency and IBD-related reinterventions during follow-up. Secondary outcomes were all type 1 endoleak, all reinterventions, rupture, and mortality during follow-up. RESULTS: A total of 38 patients were treated with a combination of EVAR with IBD. Technical success was 94.7% (n = 36/38). The 30-day survival was 100%. Median follow-up time was 31 months (range 8-56). During follow-up, no patients developed type 1b or type 3 endoleak and all hypogastric arteries at the side of IBD remained patent. The overall reintervention rate at 12 months follow-up was 5.3% (n = 2/38) and the IBD-related reintervention rate was 2.6% (n = 1/38). CONCLUSION: The combination of the Endurant II(s) and the E-liac stent graft system is an effective and safe procedure for patients with an aortoiliac aneurysm. We confirm the high hypogastric artery patency rate using IBD. Furthermore, these devices have a high technical success rate even when it is combined with an Endurant II(s) EVAR main body.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Humans , Blood Vessel Prosthesis/adverse effects , Endoleak/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Stents/adverse effects , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/surgery , Retrospective Studies , Treatment Outcome , Prosthesis Design
17.
Ann Vasc Surg ; 92: 201-210, 2023 May.
Article in English | MEDLINE | ID: mdl-36690249

ABSTRACT

BACKGROUND: To determine the importance of the hypogastric artery for the outcomes of survival, endoleaks, reinterventions, buttock claudication (BC), and perioperative mortality rate (PMR) in patients with aortoiliac aneurysms (AIA) receiving endovascular or open surgical (OS) repair. METHODS: This was a prospective consecutive cohort study of patients with AIA who underwent endovascular treatment or OS repair during the period of 2010-2021. Endovascular repair was performed with use of aortoiliac endoprosthesis associated with internal iliac artery (IIA) coil embolization and/or with iliac branch endoprosthesis (IBE) in order to preserve the IIA. The AIA OS repairs were performed with the artery ligation in order to exclude the IIA, or in some cases, the exclusion of the IIA was performed with an endosuture in the proximal stump of the artery. Three groups were identified in the postprocedural period: group 0 (no hypogastric arteries (HAs) preserved), group 1 (1 hypogastric artery preserved), and group 2 (2 hypogastric arteries preserved). RESULTS: A total of 91 patients were submitted to OS or endovascular surgery. Regarding the HA patency, there were 17 patients in group 0, 45 patients in group 1, and 29 patients in group 2. There were 17 cases of bowel ischemia (BI) (94.1% in group 0, 5.9% in group 1, and no cases in group 2, P < 0.001) most of them in group 0, with statistical significance, 12 cases of BC (91.7% in group 0, 8.3% in group 1, and no cases in group 2, P < 0.001), most of them in group 0, with statistical significance. The perioperative mortality was 14.3%, 13 patients (9 patients - 52.9% group 0, 3 patients - 6.7% group 1, and 1 patient - 3.4% group 2, P < 0.001). The linear regression analysis for survival rates showed that BI [P = 0.026 to hazard ratio (HR) = 1.69], emergency aortoiliac repair (P < 0.001, HR = 8.86), and number of HAs (P < 0.001, HR = 5.46) in postoperative were related to poorer survival rates in both univariate and multivariate analysis. The linear regression analysis showed that the number of HAs (P < 0.001, HR = 3.61) in postoperative, emergency aortoiliac repair (P = 0.002, HR 3.233), and cardiac disease (P = 0.048, HR = 3.84) were related to BI. CONCLUSIONS: In conclusion, the number of HA is crucial for adequate and safe outcomes after abdominal aortic aneurysm (AAA) repair. The main factors related to death were BI, emergency aortoiliac repair, and the number of HAs preserved. Moreover, the main factors related to BI were the number of HAs in postoperative, emergency aortoiliac repair, and cardiac disease.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Humans , Iliac Artery/diagnostic imaging , Iliac Artery/surgery , Prospective Studies , Cohort Studies , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/surgery , Iliac Aneurysm/complications , Blood Vessel Prosthesis Implantation/adverse effects , Treatment Outcome , Endovascular Procedures/adverse effects , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Aorta, Abdominal/surgery , Arteries/surgery , Retrospective Studies
19.
Vascular ; 31(3): 463-466, 2023 Jun.
Article in English | MEDLINE | ID: mdl-35220821

ABSTRACT

BACKGROUND: Behçet's disease (BD) is a rare form of systemic vasculitis that affects small to large vessels. It is characterized by mucocutaneous, pulmonary, cardiovascular, gastrointestinal, and neurological manifestations. Large vessel involvement may occur in a third of cases. Veins are usually more affected than arteries. Furthermore aneurysms are the most frequent arterial complication. CASE PRESENTATION: A 41-year-old man presented with multiple arterial aneurysms. He had previous medical history of a right popliteal aneurysm treated with a reversed femoro-popliteal venous bypass, long-term steroids and immunosuppressive treatment. On admission, diagnostic computed tomography angiography revealed multiple aneurysms, including an 87 mm aneurysm of the femoro-popliteal bypass and an abdominal aortic and left common iliac artery aneurysm. He received an intensification of medical treatment with methylprednisolone and infliximab intravenous infusion. Aorto iliac artery aneurysms were treated by infrarenal bifurcated stent graft implantation. The aneurysm of the venous femoro-popliteal bypass was treated by explantation and prosthetic repair. One month later, he presented with acute right limb ischemia related to occlusion of the right limb of the stent graft despite anticoagulation which was treated by mechanical thrombectomy. CONCLUSIONS: Vascular BD can worsen the vascular outcome after surgery. Except in an urgent context, BD must be controlled before surgery. This case report illustrates the importance of combined medical and surgical management, with first BD activity control with corticosteroids and immunosuppressive treatment, then surgical or endovascular treatment.


Subject(s)
Aortic Aneurysm, Abdominal , Behcet Syndrome , Blood Vessel Prosthesis Implantation , Iliac Aneurysm , Male , Humans , Adult , Behcet Syndrome/complications , Behcet Syndrome/diagnosis , Behcet Syndrome/drug therapy , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/etiology , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/methods , Aorta, Abdominal/surgery , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/etiology , Iliac Aneurysm/surgery
20.
J Endovasc Ther ; 30(4): 520-524, 2023 Aug.
Article in English | MEDLINE | ID: mdl-35502742

ABSTRACT

PURPOSE: The purpose of this report is to describe the use of a double-branched custom-made iliac branch device (IBD) for the endovascular repair of an aorto-bi-iliac aneurysm with concomitant bilateral hypogastric aneurysms. TECHNIQUE: A 61-year-old man on peritoneal dialysis underwent a computed tomography (CT) of the infrarenal aorta before planned kidney transplantation. The CT showed an asymptomatic aorto-bi-iliac aneurysm of 54 mm involving the hypogastric artery (HA) bilaterally (right HA 31 mm; left HA 40 mm). The treatment consisted of an endovascular aortic repair (EVAR) and the bilateral implantation of custom-manufactured IBDs with double inner branches to preserve both superior and inferior gluteal arteries. At 1 year follow-up, the patient remains free of symptoms and the postoperative CT showed a successfully excluded aneurysm with patent bridging stent grafts to all HA branches. CONCLUSION: The bilateral implantation of double-branched IBDs is a feasible technique. Preservation of both hypogastric arteries and its branches can be achieved with this technique and therefore decrease the risk of buttock claudication and other ischemic complications.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Humans , Middle Aged , Iliac Aneurysm/complications , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/surgery , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Treatment Outcome , Aorta, Abdominal/surgery , Stents , Blood Vessel Prosthesis , Prosthesis Design , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...