Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 16.349
Filter
1.
BMC Oral Health ; 24(1): 523, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702708

ABSTRACT

BACKGROUND: The rising demand for improved aesthetics has driven the utilization of recently introduced aesthetic materials for creating custom post and core restorations. However, information regarding the fracture resistance of these materials remains unclear, which limits their practical use as custom post and core restorations in clinical applications. AIM OF THE STUDY: This study aimed to evaluate the fracture resistance of three non-metallic esthetic post and core restorations and their modes of failure. MATERIALS AND METHODS: Thirty-nine single-rooted human maxillary central incisors were endodontically treated. A standardized post space preparation of 9mm length was performed to all teeth to receive custom-made post and core restorations. The prepared teeth were randomly allocated to receive a post and core restoration made of one of the following materials (n=13): glass fiber-reinforced composite (FRC), polyetheretherketone (PEEK) and polymer-infiltrated ceramic-network (PICN). An intraoral scanner was used to scan all teeth including the post spaces. Computer-aided design and computer-aided manufacturing (CAD-CAM) was used to fabricate post and core restorations. Post and core restorations were cemented using self-adhesive resin cement. All specimens were subjected to fracture resistance testing using a universal testing machine. Failure mode analysis was assessed using a stereomicroscope and SEM. The data was statistically analyzed using One-Way ANOVA test followed by multiple pairwise comparisons using Bonferroni adjusted significance level. RESULTS: Custom PEEK post and core restorations displayed the least fracture load values at 286.16 ± 67.09 N. In contrast, FRC exhibited the highest average fracture load at 452.60 ± 105.90 N, closely followed by PICN at 426.76 ± 77.99 N. In terms of failure modes, 46.2% of specimens with PICN were deemed non-restorable, while for PEEK and FRC, these percentages were 58.8% and 61.5%, respectively. CONCLUSIONS: Within the limitation of this study, both FRC and PICN demonstrated good performance regarding fracture resistance, surpassing that of PEEK.


Subject(s)
Composite Resins , Computer-Aided Design , Dental Restoration Failure , Esthetics, Dental , Post and Core Technique , Humans , Ceramics , Dental Stress Analysis , Benzophenones , Incisor/injuries , Dental Materials/chemistry , Polyethylene Glycols , Ketones/chemistry , Polymers , Glass , Materials Testing , Dental Prosthesis Design
3.
Nutrients ; 16(10)2024 May 14.
Article in English | MEDLINE | ID: mdl-38794716

ABSTRACT

It has been demonstrated that isoflurane-induced anesthesia can increase the blood glucose level, leading to hyperglycemia and several adverse effects. The administration of a mix of ketone diester (KE) and medium-chain triglyceride (MCT) oil, named KEMCT, abolished the isoflurane-anesthesia-induced increase in blood glucose level and prolonged the recovery time from isoflurane anesthesia in a male preclinical rodent model, Wistar Albino Glaxo/Rijswijk (WAG/Rij) rats. While most preclinical studies use exclusively male animals, our previous study on blood glucose changes in response to KEMCT administration showed that the results can be sex-dependent. Thus, in this study, we investigated female WAG/Rij rats, whether KEMCT gavage (3 g/kg/day for 7 days) can change the isoflurane (3%)-anesthesia-induced increase in blood glucose level and the recovery time from isoflurane-evoked anesthesia using the righting reflex. Moreover, KEMCT-induced ketosis may enhance both the extracellular level of adenosine and the activity of adenosine A1 receptors (A1Rs). To obtain information on the putative A1R mechanism of action, the effects of an A1R antagonist, DPCPX (1,3-dipropyl-8-cyclopentylxanthine; intraperitoneal/i.p. 0.2 mg/kg), on KEMCT-generated influences were also investigated. Our results show that KEMCT supplementation abolished the isoflurane-anesthesia-induced increase in blood glucose level, and this was abrogated by the co-administration of DPCPX. Nevertheless, KEMCT gavage did not change the recovery time from isoflurane-induced anesthesia. We can conclude that intragastric gavage of exogenous ketone supplements (EKSs), such as KEMCT, can abolish the isoflurane-anesthesia-induced increase in blood glucose level in both sexes likely through A1Rs in WAG/Rij rats, while recovery time was not affected in females, unlike in males. These results suggest that the administration of EKSs as an adjuvant therapy may be effective in mitigating metabolic side effects of isoflurane, such as hyperglycemia, in both sexes.


Subject(s)
Anesthetics, Inhalation , Blood Glucose , Isoflurane , Ketones , Animals , Female , Isoflurane/pharmacology , Isoflurane/administration & dosage , Blood Glucose/drug effects , Blood Glucose/metabolism , Rats , Ketones/administration & dosage , Ketones/pharmacology , Anesthetics, Inhalation/administration & dosage , Anesthetics, Inhalation/pharmacology , Rats, Wistar , Dietary Supplements , Triglycerides/blood , Triglycerides/administration & dosage , Male , Adenosine/pharmacology , Adenosine/administration & dosage , Anesthesia/methods
4.
Cancer Med ; 13(10): e7295, 2024 May.
Article in English | MEDLINE | ID: mdl-38785215

ABSTRACT

BACKGROUND: This prospective real-world study aimed to assess the efficacy and safety of eribulin in the clinical practice against advanced breast cancer (ABC) in China. PATIENTS AND METHODS: In this study, eligible patients with inoperable locally advanced or metastatic breast cancer who had experienced prior neo-/adjuvant or failed the palliative treatment with anthracycline/taxanes were included. Eribulin (1.4 mg/m2) was infused intravenously on Day 1 and Day 8 every 3 weeks until disease progression or intolerable toxicity occurred. The progression-free survival (PFS), overall response rate (ORR), disease control rate (DCR), and safety of the treatment were assessed. RESULTS: One hundred and thirty-four patients were enrolled. The median PFS (mPFS) was 4.3 months (95% CI: 0.3-15.4). The ORR and DCR was 32.1% and 79.1%, respectively. The mPFS of patients who received eribulin as first- or second-line treatment was significantly better than those who received eribulin as ≥3-line treatment (6.9 months [95% CI: 3.2-8.8] vs. 4.0 months [95% CI: 3.4-4.6], p = 0.006). The mPFS of patients with triple-negative, HER2-positive, and HER2(-)/HR(+) was 3.4 (95% CI: 2.7-4.1), 6.2 (95% CI: 2.3-10.1) and 5.0 months (95% CI: 4.1-5.9), respectively. HER2(+) patients had significantly longer PFS than TNBC patients (p = 0.022). Patients received combination therapy had a significantly longer mPFS than those who received eribulin monotherapy (5.0 months [95% CI 3.6-6.3] vs. 4.0 months [95% CI: 3.3-4.7] [p = 0.016]). Multivariate analysis revealed that MBC patients with a molecular typing of non-TNBC receiving eribulin as ≤2-line therapy and combination therapy had a low risk of disease progression. Neutropenia (33.58%), leukopenia (11.94%), and thrombocytopenia (4.48%) were the most common treatment-related adverse events. CONCLUSION: Eribulin demonstrated effective clinical activity and a favorable tolerability profile in Chinese patients with ABC in the real-world. The efficacy and safety profile were consistent with those reported in previous randomized phase 3 trials.


Subject(s)
Anthracyclines , Breast Neoplasms , Furans , Ketones , Humans , Ketones/therapeutic use , Ketones/adverse effects , Ketones/administration & dosage , Furans/therapeutic use , Furans/adverse effects , Furans/administration & dosage , Female , Middle Aged , Breast Neoplasms/drug therapy , Breast Neoplasms/pathology , Breast Neoplasms/mortality , Anthracyclines/therapeutic use , Anthracyclines/administration & dosage , Adult , Aged , Prospective Studies , Taxoids/therapeutic use , Taxoids/adverse effects , Taxoids/administration & dosage , Progression-Free Survival , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Antineoplastic Combined Chemotherapy Protocols/adverse effects , Treatment Outcome , Neoplasm Metastasis , Antineoplastic Agents/therapeutic use , Antineoplastic Agents/adverse effects , China , Polyether Polyketides
5.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Article in English | MEDLINE | ID: mdl-38795258

ABSTRACT

OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.


Subject(s)
Benzophenones , Crowns , Dental Abutments , Dental Stress Analysis , Finite Element Analysis , Ketones , Materials Testing , Polyethylene Glycols , Polymers , Titanium , Zirconium , Ketones/chemistry , Polyethylene Glycols/chemistry , Humans , Zirconium/chemistry , Titanium/chemistry , Carbon Fiber/chemistry , Dental Implant-Abutment Design , Incisor , Dental Materials/chemistry , Dental Implants, Single-Tooth , Cortical Bone , Glass/chemistry , Dental Prosthesis Design
6.
Anal Chem ; 96(21): 8713-8720, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38745346

ABSTRACT

Ketogenic diets have attracted substantial interest in the treatment of chronic diseases, but there are health risks with long-term regimes. Despite the advancements in diagnostic and therapeutic methods in modern medicine, there is a huge gap in personalized health management of this dietary strategy. Hence, we present a wearable microneedle biosensor for real-time ketone and glucose monitoring. The microneedle array possesses excellent mechanical properties, allowing for consistent sampling of interstitial biomarkers while reducing the pain associated with skin puncture. Vertical graphene with outstanding electrical conductivity provides the resulting sensor with a high sensitivity of 234.18 µA mM-1 cm-2 and a low limit detection of 1.21 µM. When this fully integrated biosensor was used in human volunteers, it displayed an attractive analytical capability for tracking the dynamic metabolite levels. Moreover, the results of the on-body evaluation established a significant correlation with commercial blood measurements. Overall, this cost-effective and efficient sensing platform can accelerate the application of a ketogenic diet in personal nutrition and wellness management.


Subject(s)
Biosensing Techniques , Diet, Ketogenic , Graphite , Needles , Wearable Electronic Devices , Graphite/chemistry , Humans , Biosensing Techniques/instrumentation , Ketones
7.
Biomater Adv ; 161: 213888, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38759305

ABSTRACT

Short carbon fiber (SCF) reinforced polymer composites are expected to possess outstanding biotribological and mechanical properties in certain direction, while the non-oriented SCF weakens its reinforcing effect in the matrix. In this work, high-oriented SCF was achieved during nozzle extrusion, and then SCF reinforced polyether-ether-ketone (PEEK) composites were fabricated by fused deposition modeling (FDM). The concrete orientation process of SCF was theoretically simulated, and significant shear stress difference was generated at both ends of SCF. As a result, the SCF was distributed in the matrix in a hierarchical structure, containing surface layer I, II and core layer. Moreover, the SCF was oriented highly along the printing direction and demonstrated a more competitive orientation distribution compared to other studies. The SCF/PEEK composites showed a considerable improvement in wear resistance by 44 % due to self-lubricating and load-bearing capability of SCF. Besides, it demonstrated enhancements in Brinell hardness, compressive and impact strength by 48.52 %, 16.42 % and 53.64 %, respectively. In addition, SCF/PEEK composites also showed good cytocompatibility. The findings gained herein are useful for developing the high-oriented SCF reinforced polymer composites with superior biotribological and mechanical properties for artificial joints.


Subject(s)
Benzophenones , Carbon Fiber , Ketones , Materials Testing , Polyethylene Glycols , Polymers , Printing, Three-Dimensional , Carbon Fiber/chemistry , Polymers/chemistry , Polyethylene Glycols/chemistry , Ketones/chemistry , Materials Testing/methods , Biocompatible Materials/chemistry , Joint Prosthesis , Humans
8.
Nature ; 629(8013): 824-829, 2024 May.
Article in English | MEDLINE | ID: mdl-38720081

ABSTRACT

Enzymes play an increasingly important role in improving the benignity and efficiency of chemical production, yet the diversity of their applications lags heavily behind chemical catalysts as a result of the relatively narrow range of reaction mechanisms of enzymes. The creation of enzymes containing non-biological functionalities facilitates reaction mechanisms outside nature's canon and paves the way towards fully programmable biocatalysis1-3. Here we present a completely genetically encoded boronic-acid-containing designer enzyme with organocatalytic reactivity not achievable with natural or engineered biocatalysts4,5. This boron enzyme catalyses the kinetic resolution of hydroxyketones by oxime formation, in which crucial interactions with the protein scaffold assist in the catalysis. A directed evolution campaign led to a variant with natural-enzyme-like enantioselectivities for several different substrates. The unique activation mode of the boron enzyme was confirmed using X-ray crystallography, high-resolution mass spectrometry (HRMS) and 11B NMR spectroscopy. Our study demonstrates that genetic-code expansion can be used to create evolvable enantioselective enzymes that rely on xenobiotic catalytic moieties such as boronic acids and access reaction mechanisms not reachable through catalytic promiscuity of natural or engineered enzymes.


Subject(s)
Biocatalysis , Boronic Acids , Enzymes , Protein Engineering , Boronic Acids/chemistry , Boronic Acids/metabolism , Crystallography, X-Ray , Directed Molecular Evolution , Enzymes/chemistry , Enzymes/metabolism , Enzymes/genetics , Ketones/chemistry , Ketones/metabolism , Kinetics , Models, Molecular , Oximes/chemistry , Oximes/metabolism , Substrate Specificity , Nuclear Magnetic Resonance, Biomolecular , Mass Spectrometry , Xenobiotics/chemistry , Xenobiotics/metabolism
9.
BMC Surg ; 24(1): 169, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38811965

ABSTRACT

BACKGROUND: Whether polyetheretherketone (PEEK) rods have potential as an alternative to titanium alloy (Ti) rods in transforaminal lumbar interbody fusion (TLIF) remains unclear, especially in cases with insufficient anterior support due to the absence of a cage. The purpose of this study was to investigate biomechanical differences between PEEK rods and Ti rods in TLIF with and without a cage. METHODS: An intact L1-L5 lumbar finite element model was constructed and validated. Accordingly, four TLIF models were developed: (1) Ti rods with a cage; (2) PEEK rods with a cage; (3) Ti rods without a cage; and (4) PEEK rods without a cage. The biomechanical properties were then compared among the four TLIF constructs. RESULTS: With or without a cage, no obvious differences were found in the effect of PEEK rods and Ti rods on the range of motion, adjacent disc stress, and adjacent facet joint force. Compared to Ti rods, PEEK rods increase the average bone graft strain (270.8-6055.2 µE vs. 319.0-8751.6 µE). Moreover, PEEK rods reduced the stresses on the screw-rod system (23.1-96.0 MPa vs. 7.2-48.4 MPa) but increased the stresses on the cage (4.6-35.2 MPa vs. 5.6-40.9 MPa) and endplates (5.7-32.5 MPa vs. 6.6-37.6 MPa). CONCLUSIONS: Regardless of whether a cage was used for TLIF, PEEK rods theoretically have the potential to serve as an alternative to Ti rods because they may provide certain stability, increase the bone graft strain, and reduce the posterior instrumentation stress, which might promote bony fusion and decrease instrumentation failure.


Subject(s)
Alloys , Benzophenones , Finite Element Analysis , Ketones , Lumbar Vertebrae , Polyethylene Glycols , Polymers , Spinal Fusion , Titanium , Humans , Spinal Fusion/instrumentation , Spinal Fusion/methods , Biomechanical Phenomena , Lumbar Vertebrae/surgery , Range of Motion, Articular , Biocompatible Materials
10.
Food Res Int ; 186: 114372, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38729730

ABSTRACT

The oxidation and degradation of fats lead to a decrease in the nutritional value of food and pose safety concerns. Saturated fatty acids also hold a significant position in the field of lipid oxidation. In this study, the oxidation products of methyl palmitate were investigated by using gas chromatography mass spectrometry (GC-MS). Seven monohydroperoxides and 72 secondary oxidation products were detected. Combined with density functional theory (DFT) calculations, the formation mechanisms of oxidation products can be summarized into four stages. The initial stage involved the formation of monohydroperoxides and alkanes, followed by the subsequent stage involving methyl x-oxo(hydroxy)hexadecanoates. The third stage involved the formation of methyl ketones, carboxylic acids, and aldehydes, while the final stage involved lactones. Meanwhile, methyl ketones were the most abundant oxidation product, approximately 25 times more abundant than aldehydes; the calculated results agreed well with the experimental results. The establishment of a comprehensive thermal oxidation mechanism for palmitic acid provided a new foundation for future lipid oxidation analyses.


Subject(s)
Gas Chromatography-Mass Spectrometry , Hot Temperature , Oxidation-Reduction , Aldehydes/chemistry , Aldehydes/analysis , Palmitates/chemistry , Palmitic Acid/chemistry , Ketones/chemistry , Carboxylic Acids/chemistry
11.
BMC Oral Health ; 24(1): 545, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730391

ABSTRACT

BACKGROUND: This Finite Element Analysis was conducted to analyze the biomechanical behaviors of titanium base abutments and several crown materials with respect to fatigue lifetime and stress distribution in implants and prosthetic components. METHODS: Five distinct designs of implant-supported single crowns were modeled, including a polyetheretherketone (PEEK), polymer-infiltrated ceramic network, monolithic lithium disilicate, and precrystallized and crystallized zirconia-reinforced lithium silicates supported by a titanium base abutment. For the static load, a 100 N oblique load was applied to the buccal incline of the palatal cusp of the maxillary right first premolar. The dynamic load was applied in the same way as in static loading with a frequency of 1 Hz. The principal stresses in the peripheral bone as well as the von Mises stresses and fatigue strength of the implants, abutments, prosthetic screws, and crowns were assessed. RESULTS: All of the models had comparable von Mises stress values from the implants and abutments, as well as comparable maximum and minimum principal stress values from the cortical and trabecular bones. The PEEK crown showed the lowest stress (46.89 MPa) in the cervical region. The prosthetic screws and implants exhibited the highest von Mises stress among the models. The lithium disilicate crown model had approximately 9.5 times more cycles to fatique values for implants and 1.7 times more cycles to fatique values for abutments than for the lowest ones. CONCLUSIONS: With the promise of at least ten years of clinical success and favorable stress distributions in implants and prosthetic components, clinicians can suggest using an implant-supported lithium disilicate crown with a titanium base abutment.


Subject(s)
Benzophenones , Crowns , Dental Abutments , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Finite Element Analysis , Titanium , Titanium/chemistry , Humans , Dental Porcelain/chemistry , Polyethylene Glycols/chemistry , Dental Materials/chemistry , Polymers , Ketones/chemistry , Zirconium/chemistry , Dental Implants, Single-Tooth , Materials Testing , Dental Implant-Abutment Design , Biomechanical Phenomena
12.
Food Res Int ; 187: 114330, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38763633

ABSTRACT

Processing technology plays a crucial role in the formation of tea aroma. The dynamic variations in volatile metabolites across different processing stages of fresh scent green tea (FSGT) were meticulously tracked utilizing advanced analytical techniques such as GC-E-Nose, GC-MS, and GC × GC-TOFMS. A total of 244 volatile metabolites were identified by GC-MS and GC × GC-TOFMS, among which 37 volatile compounds were concurrently detected by both methods. Spreading and fixation stages were deemed as pivotal processes for shaping the volatile profiles in FSGT. Notably, linalool, heptanal, 2-pentylfuran, nonanal, ß-myrcene, hexanal, 2-heptanone, pentanal, 1-octen-3-ol, and 1-octanol were highlighted as primary contributors to the aroma profiles of FSGT by combining odor activity value assessment. Furthermore, lipid degradation and glycoside hydrolysis were the main pathways for aroma formation of FSGT. The results not only elucidate the intricate variations in volatile metabolites but also offer valuable insights into enhancing the processing techniques for improved aroma quality of green tea.


Subject(s)
Food Handling , Gas Chromatography-Mass Spectrometry , Odorants , Tea , Volatile Organic Compounds , Volatile Organic Compounds/analysis , Volatile Organic Compounds/metabolism , Gas Chromatography-Mass Spectrometry/methods , Odorants/analysis , Tea/chemistry , Food Handling/methods , Electronic Nose , Aldehydes/analysis , Aldehydes/metabolism , Acyclic Monoterpenes/metabolism , Acyclic Monoterpenes/analysis , Camellia sinensis/chemistry , Camellia sinensis/metabolism , Ketones/analysis , Ketones/metabolism , Octanols
13.
Food Res Int ; 187: 114398, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38763656

ABSTRACT

Nowadays, it is important to monitor the freshness of meat during storage to protect consumers' health. Volatile organic compounds (VOCs) are responsible for odour and taste of food, and they give an indication about meat quality and freshness. This study had the aim to seek and select potential new markers of meat spoilage through a semi-quantitative analysis in five types of meat (beef, raw and baked ham, pork sausage and chicken) and then to develop a new quantitative analytical method to detect and quantify potential markers on five types of meat simultaneously. Firstly, a new headspace-solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) method was developed to evaluate the volatile profile of five types of meat, preserved at 4 °C for 5 days. Among the 40 compounds identified, 15 were chosen and selected as potential shelf-life markers on the basis of their presence in most of meat samples or/and for their constant increasing/decreasing trend within the sample. Afterwards, a quantitative HS-SPME-GC-MS analytical method was developed to confirm which VOCs can be considered markers of shelf-life for these meat products, stored at 4 °C for 12 days. Some of the compounds analyzed attracted attention as they can be considered markers of shelf-life for at least 4 types of meat: 1-butanol, 3-methylbutanol, 1-hexanol, 2-nonanone, nonanal, 1-octen-3-ol and linalool. In conclusion, in this study a new quantitative HS-SPME-GC-MS analytical method to quantity 15 VOCs in five types of meat was developed and it was demonstrated that some of the compounds quantified can be considered markers of shelf-life for some of the meat products analyzed.


Subject(s)
Food Storage , Gas Chromatography-Mass Spectrometry , Meat Products , Solid Phase Microextraction , Volatile Organic Compounds , Volatile Organic Compounds/analysis , Gas Chromatography-Mass Spectrometry/methods , Solid Phase Microextraction/methods , Meat Products/analysis , Animals , Swine , Odorants/analysis , Cattle , Aldehydes/analysis , Chickens , Ketones/analysis , Pentanols/analysis , Acyclic Monoterpenes/analysis , Octanols
14.
Langmuir ; 40(20): 10648-10662, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38712915

ABSTRACT

This study presents new insights into the potential role of polyelectrolyte interfaces in regulating low friction and interstitial fluid pressurization of cartilage. Polymer brushes composed of hydrophilic 3-sulfopropyl methacrylate potassium salt (SPMK) tethered to a PEEK substrate (SPMK-g-PEEK) are a compelling biomimetic solution for interfacing with cartilage, inspired by the natural lubricating biopolyelectrolyte constituents of synovial fluid. These SPMK-g-PEEK surfaces exhibit a hydrated compliant layer approximately 5 µm thick, demonstrating the ability to maintain low friction coefficients (µ ∼ 0.01) across a wide speed range (0.1-200 mm/s) under physiological loads (0.75-1.2 MPa). A novel polyelectrolyte-enhanced tribological rehydration mechanism is elucidated, capable of recovering up to ∼12% cartilage strain and subsequently facilitating cartilage interstitial fluid recovery, under loads ranging from 0.25 to 2.21 MPa. This is attributed to the combined effects of fluid confinement within the contact gap and the enhanced elastohydrodynamic behavior of polymer brushes. Contrary to conventional theories that emphasize interstitial fluid pressurization in regulating cartilage lubrication, this work demonstrates that SPMK-g-PEEK's frictional behavior with cartilage is independent of these factors and provides unabating aqueous lubrication. Polyelectrolyte-enhanced tribological rehydration can occur within a static contact area and operates independently of known mechanisms of cartilage interstitial fluid recovery established for converging or migrating cartilage contacts. These findings challenge existing paradigms, proposing a novel polyelectrolyte-cartilage tribological mechanism not exclusively reliant on interstitial fluid pressurization or cartilage contact geometry. The implications of this research extend to a broader understanding of synovial joint lubrication, offering insights into the development of joint replacement materials that more accurately replicate the natural functionality of cartilage.


Subject(s)
Lubrication , Polymers , Polymers/chemistry , Animals , Polyelectrolytes/chemistry , Polyethylene Glycols/chemistry , Cartilage/chemistry , Cartilage/drug effects , Surface Properties , Benzophenones/chemistry , Cartilage, Articular/chemistry , Cartilage, Articular/physiology , Ketones/chemistry
15.
Sci Rep ; 14(1): 12186, 2024 05 28.
Article in English | MEDLINE | ID: mdl-38806564

ABSTRACT

Polyetheretherketone (PEEK) is considered as an excellent biomaterial for bone grafting and connective tissue replacement. The clinical potential is, however, limited by its bioinertness, poor osteoconduction, and weak antibacterial activity. These disadvantages can be overcome by introducing suitable additives to produce mineral-polymer composites or coatings. In this work, a PEEK-based bioactive composite has been obtained by blending the polymer with magnesium phosphate (Mg3(PO4)2) particles in amounts ranging from 1 to 10 wt.% using the hot press technique. The obtained composite exhibited improved mechanical and physical properties, above the lower limits set for bone engineering applications. The tested grafts were found to not induce cytotoxicity. The presence of magnesium phosphate induced the mineralisation process with no adverse effects on the expression of the marker crucial for osteoblastic differentiation. The most promising results were observed in the grafts containing 1 wt.% of magnesium phosphate embedded within the PEEK matrix. The improved bioactivity of grafts, together with suitable physical-chemical and mechanical properties, indicate this composite as a promising orthopaedic implant material.


Subject(s)
Benzophenones , Biocompatible Materials , Ketones , Phosphates , Polyethylene Glycols , Polymers , Ketones/chemistry , Ketones/pharmacology , Polymers/chemistry , Polyethylene Glycols/chemistry , Biocompatible Materials/chemistry , Phosphates/chemistry , Humans , Magnesium Compounds/chemistry , Magnesium Compounds/pharmacology , Materials Testing , Osteoblasts/drug effects , Osteoblasts/metabolism
16.
J Agric Food Chem ; 72(21): 11928-11937, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38753466

ABSTRACT

The discovery of structurally distinct leads is imperative in modern agrochemical science. Inspired by eudistomins Y and the framework-related pharmaceuticals, aryl heteroaryl ketone was drawn as a common model intriguing the design and divergent synthesis of 14 kinds of heteroaryl ketones aligned with their oxime derivatives. Antifungal function-oriented phenotypical screen protruded benzothiazolyl-phenyl oxime 5a as a promising model, and the concomitant modification led to benzothiazolyl oxime 5am (EC50 = 5.17 µM) as a superior lead than fluoxastrobin (EC50 = 7.54 µM) against Sclerotinia sclerotiorum. Scaffold hopping of the phenyl subunit identified benzothiazolyl-pyridyl oxime as a novel antifungal scaffold accompanied by acquiring oxime 5bm with remarkable activity (EC50 = 3.57 µM) against Pyricularia oryzae. Molecular docking showed that candidate 5am could form more hydrogen bonds with the amino acid residues of actin than metrafenone. This compound also demonstrated better curative efficacy than that of fluoxastrobin and metrafenone in controlling the plant disease caused by S. sclerotiorum. These results rationalize the discovery of antifungal candidates based on aryl heteroaryl ketone.


Subject(s)
Ascomycota , Drug Design , Fungicides, Industrial , Ketones , Molecular Docking Simulation , Plant Diseases , Fungicides, Industrial/pharmacology , Fungicides, Industrial/chemistry , Fungicides, Industrial/chemical synthesis , Ascomycota/drug effects , Ascomycota/chemistry , Ketones/chemistry , Ketones/pharmacology , Structure-Activity Relationship , Plant Diseases/microbiology , Molecular Structure , Oximes/chemistry , Oximes/pharmacology , Antifungal Agents/pharmacology , Antifungal Agents/chemistry , Antifungal Agents/chemical synthesis
17.
Sci Rep ; 14(1): 11940, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38789658

ABSTRACT

The classic ketogenic diet is an effective treatment option for drug-resistant epilepsy, but its high fat content challenges patient compliance. Optimizing liver ketone production guided by a method comparing substrates for their ketogenic potential may help to reduce the fat content of the diet without loss in ketosis induction. Here, we present a liver cell assay measuring the ß-hydroxybutyrate (ßHB) yield from fatty acid substrates. Even chain albumin-conjugated fatty acids comprising between 4 and 18 carbon atoms showed a sigmoidal concentration-ßHB response curve (CRC) whereas acetate and omega-3 PUFAs produced no CRC. While CRCs were not distinguished by their half-maximal effective concentration (EC50), they differed by maximum response, which related inversely to the carbon chain length and was highest for butyrate. The assay also suitably assessed the ßHB yield from fatty acid blends detecting shifts in maximum response from exchanging medium chain fatty acids for long chain fatty acids. The assay further detected a dual role for butyrate and hexanoic acid as ketogenic substrate at high concentration and ketogenic enhancer at low concentration, augmenting the ßHB yield from oleic acid and a fatty acid blend. The assay also found propionate to inhibit ketogenesis from oleic acid and a fatty acid blend at low physiological concentration. Although the in vitro assay shows promise as a tool to optimize the ketogenic yield of a fat blend, its predictive value requires human validation.


Subject(s)
3-Hydroxybutyric Acid , Diet, Ketogenic , Hepatocytes , Ketones , Diet, Ketogenic/methods , Humans , Hepatocytes/metabolism , Ketones/metabolism , 3-Hydroxybutyric Acid/metabolism , Epilepsy/diet therapy , Epilepsy/metabolism , Fatty Acids/metabolism , Drug Resistant Epilepsy/diet therapy , Drug Resistant Epilepsy/metabolism
18.
J Agric Food Chem ; 72(20): 11321-11330, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38714361

ABSTRACT

4-Hydroxyphenylpyruvate dioxygenase (HPPD) is a crucial target enzyme in albino herbicides. The inhibition of HPPD activity interferes with the synthesis of carotenoids, blocking photosynthesis and resulting in bleaching and necrosis. To develop herbicides with excellent activity, a series of 3-hydroxy-2-(6-substituted phenoxynicotinoyl)-2-cyclohexen-1-one derivatives were designed via active substructure combination. The title compounds were characterized via infrared spectroscopy, 1H and 13C nuclear magnetic resonance spectroscopies, and high-resolution mass spectrometry. The structure of compound III-17 was confirmed via single-crystal X-ray diffraction. Preliminary tests demonstrated that some compounds had good herbicidal activity. Crop safety tests revealed that compound III-29 was safer than the commercial herbicide mesotrione in wheat and peanuts. Moreover, the compound exhibited the highest inhibitory activity against Arabidopsis thaliana HPPD (AtHPPD), with a half-maximal inhibitory concentration of 0.19 µM, demonstrating superior activity compared with mesotrione (0.28 µM) in vitro. A three-dimensional quantitative structure-activity relationship study revealed that the introduction of smaller groups to the 5-position of cyclohexanedione and negative charges to the 3-position of the benzene ring enhanced the herbicidal activity. A molecular structure comparison demonstrated that compound III-29 was beneficial to plant absorption and conduction. Molecular docking and molecular dynamics simulations further verified the stability of the complex formed by compound III-29 and AtHPPD. Thus, this study may provide insights into the development of green and efficient herbicides.


Subject(s)
4-Hydroxyphenylpyruvate Dioxygenase , Arabidopsis , Drug Design , Enzyme Inhibitors , Herbicides , Molecular Docking Simulation , Herbicides/chemistry , Herbicides/pharmacology , Herbicides/chemical synthesis , 4-Hydroxyphenylpyruvate Dioxygenase/antagonists & inhibitors , 4-Hydroxyphenylpyruvate Dioxygenase/chemistry , 4-Hydroxyphenylpyruvate Dioxygenase/metabolism , Enzyme Inhibitors/chemistry , Enzyme Inhibitors/chemical synthesis , Enzyme Inhibitors/pharmacology , Arabidopsis/drug effects , Arabidopsis/growth & development , Structure-Activity Relationship , Molecular Structure , Ketones/chemistry , Ketones/pharmacology , Ketones/chemical synthesis , Cyclohexanones/chemistry , Cyclohexanones/pharmacology , Cyclohexanones/chemical synthesis , Triticum/chemistry , Arabidopsis Proteins/antagonists & inhibitors , Arabidopsis Proteins/chemistry , Arabidopsis Proteins/metabolism
19.
PLoS One ; 19(5): e0301041, 2024.
Article in English | MEDLINE | ID: mdl-38701088

ABSTRACT

OBJECTIVE: To evaluate the safety and performance of an implantable near-infrared (NIR) spectroscopy sensor for multi-metabolite monitoring of glucose, ketones, lactate, and ethanol. RESEARCH DESIGN AND METHODS: This is an early feasibility study (GLOW, NCT04782934) including 7 participants (4 with type 1 diabetes (T1D), 3 healthy volunteers) in whom the YANG NIR spectroscopy sensor (Indigo) was implanted for 28 days. Metabolic challenges were used to vary glucose levels (40-400 mg/dL, 2.2-22.2 mmol/L) and/or induce increases in ketones (ketone drink, up to 3.5 mM), lactate (exercise bike, up to 13 mM) and ethanol (4-8 alcoholic beverages, 40-80g). NIR spectra for glucose, ketones, lactate, and ethanol levels analyzed with partial least squares regression were compared with blood values for glucose (Biosen EKF), ketones and lactate (GlucoMen LX Plus), and breath ethanol levels (ACE II Breathalyzer). The effect of potential confounders on glucose measurements (paracetamol, aspartame, acetylsalicylic acid, ibuprofen, sorbitol, caffeine, fructose, vitamin C) was investigated in T1D participants. RESULTS: The implanted YANG sensor was safe and well tolerated and did not cause any infectious or wound healing complications. Six out 7 sensors remained fully operational over the entire study period. Glucose measurements were sufficiently accurate (overall mean absolute (relative) difference MARD of 7.4%, MAD 8.8 mg/dl) without significant impact of confounders. MAD values were 0.12 mM for ketones, 0.16 mM for lactate, and 0.18 mM for ethanol. CONCLUSIONS: The first implantable multi-biomarker sensor was shown to be well tolerated and produce accurate measurements of glucose, ketones, lactate, and ethanol. TRIAL REGISTRATION: Clinical trial identifier: NCT04782934.


Subject(s)
Ethanol , Feasibility Studies , Ketones , Lactic Acid , Spectroscopy, Near-Infrared , Humans , Ketones/analysis , Male , Ethanol/analysis , Spectroscopy, Near-Infrared/methods , Adult , Female , Lactic Acid/analysis , Lactic Acid/blood , Blood Glucose/analysis , Middle Aged , Diabetes Mellitus, Type 1/blood , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Glucose/analysis
20.
BMC Oral Health ; 24(1): 513, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38698366

ABSTRACT

BACKGROUND: This study aims to evaluate the effect of surface treatment and resin cement on the shear bond strength (SBS) and mode of failure of polyetheretherketone (PEEK) to lithium disilicate ceramic (LDC). This is suggested to study alternative veneering of PEEK frameworks with a ceramic material. METHODS: eighty discs were prepared from PEEK blank and from lithium disilicate ceramic. Samples were divided into four groups according to surface treatment: Group (A) air abraded with 110 µm Al2O3, Group (AP) air abrasion and primer application, Group (S) 98% sulfuric acid etching for 60 s, Group (SP) Sulfuric acid and primer. Each group was subdivided into two subgroups based on resin cement type used for bonding LDC:1) subgroup (L) self- adhesive resin cement and 2) subgroup (B) conventional resin cement (n = 10). Thermocycling was done for all samples. The bond strength was assessed using the shear bond strength test (SBS). Failure mode analysis was done at 50X magnification with a stereomicroscope. Samples were chosen from each group for scanning electron microscope (SEM). The three-way nested ANOVA followed by Tukey's post hoc test were used for statistical analysis of results. Comparisons of effects were done utilizing one way ANOVA and (p < 0.05). RESULTS: The highest mean of shear bond strength values was demonstrated in Group of air abrasion with primer application using conventional resin cement (APB) (12.21 ± 2.14 MPa). Sulfuric acid groups showed lower shear bond strength values and the majority failed in thermocycling especially when no primer was applied. The failure mode analysis showed that the predominant failure type was adhesive failure between cement and PEEK, while the remaining was mixed failure between cement and PEEK. CONCLUSION: The air abrasion followed by primer application and conventional resin cement used for bonding Lithium Disilicate to PEEK achieved the best bond strength. Primer application did not have an effect when self-adhesive resin cement was used in air-abraded groups. Priming step is mandatory whenever sulfuric acid etching surface treatment is utilized for PEEK.


Subject(s)
Benzophenones , Dental Bonding , Dental Porcelain , Dental Stress Analysis , Ketones , Materials Testing , Polyethylene Glycols , Polymers , Resin Cements , Shear Strength , Surface Properties , Dental Bonding/methods , Acid Etching, Dental/methods , Sulfuric Acids , Ceramics/chemistry , Air Abrasion, Dental/methods , Aluminum Oxide , Dental Veneers , Dental Etching/methods , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...