Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Chromatogr ; 34(11): e4928, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32567713

ABSTRACT

A practical, sensitive, and robust UPLC-MS/MS method was developed and validated to quantify lacosamide in human plasma. A simple one-step protein precipitation was used to extract lacosamide and labeled lacosamide-13C, D3 as an internal standard (IS) from 150-µL plasma. The extracts were analyzed on an Eclipse Plus C18 column (50 × 2.1 mm, 1.8 µm) using 0.1% formic acid in water and methanol:acetonitrile (50:50, v/v) under gradient conditions. The extracts were quantified on LCMS-8040 using electrospray ionization source operated in positive ionization and multiple reaction monitoring modes. The method showed good linearity from 0.02 to 20 µg/mL, which was adequate to cover lacosamide concentration assayed in formulations with different strengths. The bioanalytical assay was fully validated as per current regulatory guidelines. The intra-batch and inter-batch precision values of lacosamide were less than 4.6%. Lacosamide was found to be stable at different storage conditions. The extraction recoveries and IS-normalized matrix factors for lacosamide ranged from 97.17 to 99.68% and from 0.973 to 1.012, respectively. The validated method was successfully applied to a pharmacokinetic study with three lacosamide formulations (50, 100, and 200 mg) in 36 healthy subjects. The assay reliability was determined by reanalysis of 81 subject samples.


Subject(s)
Chromatography, High Pressure Liquid/methods , Lacosamide/blood , Lacosamide/pharmacokinetics , Spectrometry, Mass, Electrospray Ionization/methods , Adult , Humans , Lacosamide/chemistry , Limit of Detection , Linear Models , Male , Middle Aged , Reproducibility of Results
2.
Neurotherapeutics ; 17(1): 309-328, 2020 01.
Article in English | MEDLINE | ID: mdl-31486023

ABSTRACT

In our recent studies, we identified compound N-benzyl-2-(2,5-dioxopyrrolidin-1-yl)propanamide (AS-1) as a broad-spectrum hybrid anticonvulsant which showed potent protection across the most important animal acute seizure models such as the maximal electroshock (MES) test, the subcutaneous pentylenetetrazole (s.c. PTZ) test, and the 6-Hz (32 mA) test in mice. Therefore, AS-1 may be recognized as a candidate for new anticonvulsant effective in different types of human epilepsy with a favorable safety margin profile determined in the rotarod test in mice. In the aim of further pharmacological evaluation of AS-1, in the current study, we examined its activity in the 6-Hz (44 mA) test, which is known as the model of drug-resistant epilepsy. Furthermore, we determined also the antiseizure activity in the kindling model of epilepsy induced by repeated injection of pentylenetetrazole (PTZ) in mice. As a result, AS-1 revealed relatively potent protection in the 6-Hz (44 mA) test, as well as delayed the progression of kindling induced by repeated injection of PTZ in mice at doses of 15 mg/kg, 30 mg/kg, and 60 mg/kg. Importantly, the isobolographic analysis showed that a combination of AS-1 and valproic acid (VPA) at the fixed ratio of 1:1 displayed a supra-additive (synergistic) interaction against PTZ-induced seizures in mice. Thus, AS-1 may be potentially used in an add-on therapy with VPA. Moreover, incubation of zebrafish larvae with AS-1 substantially decreased the number, cumulative but not the mean duration of epileptiform-like events in electroencephalographic assay. Finally, the in vitro ADME-Tox studies revealed that AS-1 is characterized by a very good permeability in the parallel artificial membrane permeability assay test, excellent metabolic stability on human liver microsomes (HLMs), no significant influence on CYP3A4/CYP2D6 activity, and moderate inhibition of CYP2C9 in a concentration of 10 µM, as well as no hepatotoxic properties in HepG2 cells (concentration of 10 µM).


Subject(s)
Anticonvulsants/administration & dosage , Anticonvulsants/chemistry , Epilepsy/drug therapy , Seizures/drug therapy , Animals , Behavior, Animal/drug effects , Dose-Response Relationship, Drug , Epilepsy/chemically induced , Ethosuximide/chemistry , Lacosamide/chemistry , Levetiracetam/chemistry , Male , Mice , Pentylenetetrazole/administration & dosage , Pyrrolidines/administration & dosage , Pyrrolidines/chemistry , Seizures/chemically induced , Valproic Acid/administration & dosage , Zebrafish
3.
Biomed Chromatogr ; 33(9): e4554, 2019 Sep.
Article in English | MEDLINE | ID: mdl-30985932

ABSTRACT

A simple and highly sensitive ultra-high-performance liquid chromatographic-diode array (UHPLC-DAD) detection method was developed and validated for the simultaneous estimation of levetiracetam (LEV) and lacosamide (LAC). It was clinically proven that the combination of LEV and LAC exhibits a synergistic effect against refractory seizures in mice, which was the motivation for the analysis of this binary mixture both in bulk and in human urine samples. The binary mixture was resolved on a Hypersil BDS C18 analytical column, utilizing a mobile phase of 0.050 mol L-1 phosphate buffer (pH 5.60), methanol and acetonitrile in the ratio (80:10:10 v/v/v) using catechol as an internal standard. The mobile phase was pumped at a flow rate of 1.2 mL min-1 with diode array detection at 205 nm for both drugs and 270 nm for IS. Calibration curves were linear with correlation coefficient >0.9990 over the studied concentration range of 0.1-70.0 µg mL-1 for both drugs. The developed method was reproducible with low relative standard deviation values for intra- and inter-day precision (<2.0%). Both drugs were determined in bulk, pharmaceutical formulations and human urine samples without any interference from complex matrices.


Subject(s)
Anticonvulsants/urine , Chromatography, High Pressure Liquid/methods , Lacosamide/urine , Levetiracetam/urine , Adult , Anticonvulsants/chemistry , Anticonvulsants/pharmacokinetics , Drug Synergism , Female , Humans , Lacosamide/chemistry , Lacosamide/pharmacokinetics , Levetiracetam/chemistry , Levetiracetam/pharmacokinetics , Limit of Detection , Linear Models , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...