Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 6.657
Filter
1.
Biosens Bioelectron ; 259: 116380, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38754193

ABSTRACT

Exosomes, as novel biomarker for liquid biopsy, exhibit huge important potential value for cancer diagnosis. However, various proteins show different expression levels on exosomal membrane, and the absolute concentration of exosomes in clinical samples is easily influenced by a number of factors. Here, we developed a CRISPR/Cas12a and aptamer-chemiluminescence based analysis (CACBA) for the relative abundance determination of tumor-related protein positive exosomes in plasma for breast cancer diagnosis. The total concentration of exosomes was determined through captured CD63 using a CRISPR/Cas12a-based method with the LoD of 8.97 × 103 particles/µl. Meanwhile, EpCAM and MUC1 positive exosomes were quantitatively detected by aptamer-chemiluminescence (ACL) based method with the LoD of 1.45 × 102 and 3.73 × 102 particles/µl, respectively. It showed that the percentages of EpCAM and MUC1 positive exosomes offered an excellent capability to differentiate breast cancer patients and healthy donors. The high sensitivity, strong specificity, outstanding anti-interference capability, and steady recovery rate of this approach offered higher accuracy and robustness than the commercialized method in clinical trial. In addition with good stability, easy preparation and low cost, this method not only provides a new approach to rapid analysis of exosome proteins, it may be quickly extended to the diagnoses of various cancers.


Subject(s)
Aptamers, Nucleotide , Biomarkers, Tumor , Biosensing Techniques , Breast Neoplasms , CRISPR-Cas Systems , Epithelial Cell Adhesion Molecule , Exosomes , Mucin-1 , Humans , Breast Neoplasms/diagnosis , Breast Neoplasms/blood , Breast Neoplasms/genetics , Exosomes/chemistry , Exosomes/genetics , Female , Aptamers, Nucleotide/chemistry , Biosensing Techniques/methods , Mucin-1/blood , Mucin-1/genetics , Mucin-1/analysis , Biomarkers, Tumor/blood , Biomarkers, Tumor/genetics , Epithelial Cell Adhesion Molecule/genetics , Luminescent Measurements/methods , Tetraspanin 30 , Limit of Detection
2.
Anal Chim Acta ; 1309: 342677, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38772666

ABSTRACT

BACKGROUND: Rapid and sensitive detection for acetamiprid, a kind of widely used neonicotinoid insecticide, is very meaningful for the development of modern agriculture and the protection of human health. Highly stable electrochemiluminescence (ECL) materials are one of the key factors in ECL sensing technology. ECL materials prepared by porous materials (e.g., MOFs) coated with chromophores have been used for ECL sensing detection, but these materials have poor stability because the chromophores escape when they are in aqueous solution. Therefore, the development of highly stable ECL materials is of great significance to improve the sensitivity of ECL sensing technology. RESULTS: In this work, by combining etched metal-organic frameworks (E-UIO-66-NH2) as carrier with Tris(4,4'-dicarboxylic acid-2,2'-bipyridine)Ru(II) chloride (Ru(dcbpy)32+) as signal probe via amide bonds, highly stable nanocomposites (E-UIO-66-NH2-Ru) with excellent ECL performance were firstly prepared. Then, using MoS2 loaded with AuNPs as substrate material and co-reactant promoter, a signal off-on-off ECL aptamer sensor was prepared for sensitive detection of acetamiprid. Due to the excellent catalytic activity of E-UIO-66-NH2-Ru and MoS2@Au towards K2S2O8, the ECL signals can be enhanced by multiple signal enhancement pathways, the prepared ECL aptamer sensor could achieve sensitive detection of acetamiprid in the linear range of 10-13 to10-7 mol L-1, with the limit of detection (LOD) of 2.78ⅹ10-15 mol L-1 (S/N = 3). After the evaluation of actual sample testing, this sensing platform was proven to be an effective method for the detection of acetamiprid in food and agricultural products. SIGNIFICANCE AND NOVELTY: The E-UIO-66-NH2-Ru prepared by linking Ru(dcbpy)32+ to E-UIO-66-NH2 via amide bonding has very high stability. The synergistic catalytic effect of MoS2 and AuNPs enhanced the ECL signal. By exploring the sensing mechanism and evaluating the actual sample tests, the proposed signal "on-off" ECL sensing strategy was proved to be an effective and excellent ECL sensing method for sensitive and stable detection of acetamiprid.


Subject(s)
Aptamers, Nucleotide , Electrochemical Techniques , Luminescent Measurements , Metal-Organic Frameworks , Neonicotinoids , Neonicotinoids/analysis , Electrochemical Techniques/methods , Aptamers, Nucleotide/chemistry , Luminescent Measurements/methods , Metal-Organic Frameworks/chemistry , Ruthenium/chemistry , Biosensing Techniques/methods , Limit of Detection , Coordination Complexes/chemistry , Insecticides/analysis
3.
Luminescence ; 39(5): e4776, 2024 May.
Article in English | MEDLINE | ID: mdl-38769690

ABSTRACT

The purpose of the work was to find optimal conditions for bioluminescent enzymatic analysis of saliva (based on the use of NADH:FMN oxidoreductase + luciferase) and then to determine the biological effect of using bioluminescence assay of saliva to study the physiological state of the body under normal and pathological conditions. The saliva of snowboarders and students were studied in the "rest-training" model. The saliva of patients diagnosed with acute pharyngitis was examined in the "sick-healthy" model. Bioluminescence assay was performed with a lyophilized and immobilized bi-enzyme system using cuvette, plate, and portable luminometers. The concentrations of secretory immunoglobulin A (sIgA) and cortisol were determined by enzyme immunoassay, and the total protein content was measured by spectrophotometric method. The activity of the bioluminescent system enzymes increased as the amount and volume of saliva in the sample was decreased. The cuvette and plate luminometers were sensitive to changes in the luminescence intensity in saliva assay. Luminescence intensity correlated with the concentrations of sIgA and cortisol. The integrated bioluminescent index for saliva was reduced in the "rest-training" model and increased in the "sick-healthy" model. Thus, the non-invasive bioluminescent saliva analysis may be a promising tool for assessing the health of the population.


Subject(s)
Luminescent Measurements , Saliva , Humans , Saliva/enzymology , Saliva/chemistry , Luminescent Measurements/methods , Biological Assay , Hydrocortisone/analysis , Hydrocortisone/metabolism , Luciferases/metabolism , Luciferases/chemistry , Immunoglobulin A, Secretory/analysis , Immunoglobulin A, Secretory/metabolism
4.
ACS Chem Biol ; 19(5): 1035-1039, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38717306

ABSTRACT

Red-shifted bioluminescence is highly desirable for diagnostic and imaging applications. Herein, we report a semisynthetic NanoLuc (sNLuc) based on complementation of a split NLuc (LgBiT) with a synthetic peptide (SmBiT) functionalized with a fluorophore for BRET emission. We observed exceptional BRET ratios with diverse fluorophores, notably in the red (I674/I450 > 14), with a brightness that is sufficient for naked eye detection in blood or through tissues. To exemplify its utility, LgBiT was fused to a miniprotein that binds HER2 (affibody, ZHER2), and the selective detection of HER2+ SK-BR-3 cells over HER2- HeLa cells was demonstrated.


Subject(s)
Luminescent Measurements , Humans , HeLa Cells , Luminescent Measurements/methods , Luciferases/genetics , Luciferases/metabolism , Receptor, ErbB-2/metabolism , Cell Line, Tumor , Fluorescent Dyes/chemistry
5.
Anal Methods ; 16(20): 3271-3277, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38738547

ABSTRACT

The quantification of microalgae cells is crucial for the treatment of ships' ballast water. However, achieving rapid detection of microalgae cells remains a substantial challenge. Here, we develop a new method for rapid and effective detection of microalgae concentration by utilizing upconversion nanoprobes (UCNPs) of NaYF4:Er3+,Tm3+. Three ligands, carboxylated methoxypolyethylene glycols with 5000 and 2000 molecular weights (mPEG-COOH-5, mPEG-COOH-2) and D-gluconic acid sodium salt (DGAS), were used to convert hydrophobic UCNPs into a hydrophilic state through modification. The results show that the mPEG-COOH-5 modified UCNPs present the highest stability in an aqueous solution. Fourier Transform Infrared Spectroscopy (FTIR) measurements reveal the presence of a significant number of -COOH functional groups on UCNPs after the mPEG-COOH-5 modification. These -COOH groups enhance the hydrophilicity and biocompatibility of UCNPs. The soluble UCNPs were directly mixed with microalgae, and the upconversion luminescence (UCL) spectra of the UCNPs were recorded immediately after thorough shaking. This greatly reduces the measurement time and could realize rapid onboard detection. In this sensing procedure, the UCNPs with red UCL functioned as energy donors, while microalgae with red absorption served as an energy acceptor. The UCL gradually diminishes with an increase in microalgae concentration based on the inner filter effect, thus establishing a relationship between UCL and microalgae concentration. The accuracy of the detection is further validated through the traditional microscope counting method. These findings pave the way for a novel rapid strategy to assess microalgae concentration using UCNPs.


Subject(s)
Microalgae , Microalgae/chemistry , Nanoparticles/chemistry , Polyethylene Glycols/chemistry , Yttrium/chemistry , Luminescent Measurements/methods , Fluorides/chemistry , Erbium/chemistry , Hydrophobic and Hydrophilic Interactions
6.
Luminescence ; 39(5): e4775, 2024 May.
Article in English | MEDLINE | ID: mdl-38745525

ABSTRACT

A new smartphone-based chemiluminescence method has been introduced for the quantitative analysis of CL-20 (Hexanitroazaisowuertzitan) explosive. The solvent mixture, oxidizer agent, and concentration of the reactants were optimized using statistical procedures. CL-20 explosive showed a quenching effect on the chemiluminescence intensity of the luminol-NaClO reaction in the solvent mixture of DMSO/H2O. A smartphone was used as a detector to record the light intensity of chemiluminescence reaction as a video file. The recorded video file was converted to an analytical signal as intensity luminescence-time curve by a written code in MATLAB software. Dynamic range and limit of detection of the proposed method were obtained 2.0-240.0 and 1.1 mg⋅L-1, respectively, in optimized concentrations 1.5 × 10-3 mol⋅L-1 luminol and 1.0 × 10-2 mol⋅L-1 NaClO. Precursors TADB, HBIW, and TADNIW in CL-20 explosive synthesis did not show interference in measurement the CL-20 purity. The analysis of CL-20 spiked samples of soil and water indicated the satisfactory ability of the method in the analysis of real samples. The interaction of CL-20 molecules and OCl- ions is due to quench of chemiluminescence reaction of the luminol-NaClO.


Subject(s)
Luminescent Measurements , Luminol , Smartphone , Luminescent Measurements/methods , Luminescent Measurements/instrumentation , Luminol/chemistry , Explosive Agents/analysis , Luminescence , Limit of Detection
7.
Int J Mol Sci ; 25(10)2024 May 08.
Article in English | MEDLINE | ID: mdl-38791162

ABSTRACT

Early detection of drug-induced kidney injury is essential for drug development. In this study, multiple low-dose aristolochic acid (AA) and cisplatin (Cis) injections increased renal mRNA levels of inflammation, fibrosis, and renal tubule injury markers. We applied a serum amyloid A3 (Saa3) promoter-driven luciferase reporter (Saa3 promoter-luc mice) to these two tubulointerstitial nephritis models and performed in vivo bioluminescence imaging to monitor early renal pathologies. The bioluminescent signals from renal tissues with AA or CIS injections were stronger than those from normal kidney tissues obtained from normal mice. To verify whether the visualized bioluminescence signal was specifically generated by the injured kidney, we performed in vivo bioluminescence analysis after opening the stomachs of Saa3 promoter-luc mice, and the Saa3-mediated bioluminescent signal was specifically detected in the injured kidney. This study showed that Saa3 promoter activity is a potent non-invasive indicator for the early detection of drug-induced nephrotoxicity.


Subject(s)
Aristolochic Acids , Luciferases , Promoter Regions, Genetic , Serum Amyloid A Protein , Animals , Serum Amyloid A Protein/genetics , Serum Amyloid A Protein/metabolism , Mice , Luciferases/metabolism , Luciferases/genetics , Aristolochic Acids/toxicity , Genes, Reporter , Cisplatin/toxicity , Cisplatin/adverse effects , Luminescent Measurements/methods , Male , Kidney Diseases/chemically induced , Kidney Diseases/genetics , Kidney Diseases/metabolism , Kidney Diseases/pathology , Kidney/metabolism , Kidney/drug effects , Kidney/pathology , Disease Models, Animal , Mice, Inbred C57BL
8.
Biosens Bioelectron ; 258: 116356, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38705073

ABSTRACT

In this work, the dual-ligand lanthanide metal-organic framework (MOF)-based electrochemiluminescence (ECL) sensor was constructed for the detection of miRNA-128 in glioblastoma (GBM) diagnosis. The luminescent Eu-MOF (EuBBN) was synthesized with terephthalic acid (BDC) and 2-amino terephthalic acid (BDC-NH2) as dual-ligand. Due to the antenna effect, EuBBN with conjugated-π structure exhibited strong luminescent signal and high quantum efficiency, which can be employed as ECL nanoprobe. Furthermore, the novel plasmonic CuS@Au heterostructure array has been prepared. The localized surface plasmon resonance coupling effect of the CuS@Au heterostructure array can amplify the ECL signal of EuBBN significantly. The EuBBN/CuS@Au heterostructure array-based sensing system has been prepared for the detection of miRNA-128 with a wide linear range from 1 fM to 1 nM and a detection limit of 0.24 fM. Finally, miRNA-128 in the clinic GBM tissue sample has been analysis for the distinguish of tumor grade successfully. The results demonstrated that the dual-ligand MOF/CuS@Au heterostructure array-based ECL sensor can provide important support for the development of GBM diagnosis.


Subject(s)
Biosensing Techniques , Europium , Glioblastoma , Gold , Metal-Organic Frameworks , MicroRNAs , MicroRNAs/analysis , Glioblastoma/diagnosis , Humans , Metal-Organic Frameworks/chemistry , Biosensing Techniques/methods , Gold/chemistry , Europium/chemistry , Limit of Detection , Luminescent Measurements/methods , Ligands , Electrochemical Techniques/methods , Brain Neoplasms/diagnosis , Phthalic Acids/chemistry , Metal Nanoparticles/chemistry , Copper/chemistry
9.
Viruses ; 16(5)2024 05 16.
Article in English | MEDLINE | ID: mdl-38793672

ABSTRACT

Until recently, the diagnosis of feline infectious peritonitis (FIP) in cats usually led to euthanasia, but recent research has revealed that antiviral drugs, including the nucleoside analog GS-441524, have the potential to effectively cure FIP. Alpha-1-acid glycoprotein (AGP) has been suggested as a diagnostic marker for FIP. However, AGP quantification methods are not easily accessible. This study aimed to establish a Spatial Proximity Analyte Reagent Capture Luminescence (SPARCLTM) assay on the VetBio-1 analyzer to determine the AGP concentrations in feline serum and effusion samples. Linearity was found in serial dilutions between 1:2000 and 1:32,000; the intra-run and inter-run precision was <5% and <15%, respectively; and AGP was stable in serum stored for at least 8 days at room temperature, at 4 °C and at -20 °C. Cats with confirmed FIP had significantly higher serum AGP concentrations (median: 2954 µg/mL (range: 200-5861 µg/mL)) than those with other inflammatory diseases (median: 1734 µg/mL (305-3449 µg/mL)) and clinically healthy cats (median 235 µg/mL (range: 78-616 µg/mL); pKW < 0.0001). The AGP concentrations were significantly higher in the effusions from cats with FIP than in those from diseased cats without FIP (pMWU < 0.0001). The AGP concentrations in the serum of cats with FIP undergoing GS-441524 treatment showed a significant drop within the first seven days of treatment and reached normal levels after ~14 days. In conclusion, the VetBio-1 SPARCLTM assay offers a precise, fast and cost-effective method to measure the AGP concentrations in serum and effusion samples of feline patients. The monitoring of the AGP concentration throughout FIP treatment provides a valuable marker to evaluate the treatment's effectiveness and identify potential relapses at an early stage.


Subject(s)
Biomarkers , Feline Infectious Peritonitis , Luminescent Measurements , Orosomucoid , Cats , Animals , Feline Infectious Peritonitis/diagnosis , Feline Infectious Peritonitis/drug therapy , Feline Infectious Peritonitis/virology , Feline Infectious Peritonitis/blood , Biomarkers/blood , Orosomucoid/analysis , Orosomucoid/metabolism , Luminescent Measurements/methods , Prognosis , Antiviral Agents/therapeutic use , Female , Male , Coronavirus, Feline/isolation & purification
10.
Food Chem ; 451: 139461, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38701733

ABSTRACT

Copper as a widely applied element in food supply chain can cause serious contamination issues that threats food safety. In this research, we present a quick and visible method for trace copper ion (Cu2+) quantification in practical food samples. Polymer dots (Pdots) were firstly conjugated with a copper-specific DNA aptamer and then tailored with rhodamine B (RhB) to extinguish the electrochemiluminescence (ECL) signal through a resonance energy transfer process. The selective release of RhB leads to signal restoration when exposed to trace Cu2+ levels, achieving remarkable linearity with the logarithm of Cu2+ concentration within the range of 1 ng/L to 10 µg/L with an impressively low limit of detection at 11.8 pg/L. Most notably, our device was also applicable on visualizing and quantifying trace Cu2+ (∼0.2 µg/g) in practical Glycyrrhiza uralensis Fisch. samples, underscoring its potential as a tool for the early prevention of potential copper contamination in food samples.


Subject(s)
Copper , Electrochemical Techniques , Food Contamination , Luminescent Measurements , Copper/analysis , Copper/chemistry , Food Contamination/analysis , Luminescent Measurements/instrumentation , Luminescent Measurements/methods , Electrochemical Techniques/instrumentation , Limit of Detection , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Food Analysis/methods , Aptamers, Nucleotide/chemistry , Quantum Dots/chemistry
11.
J Am Chem Soc ; 146(19): 13406-13416, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38698549

ABSTRACT

Bioluminescent indicators are power tools for studying dynamic biological processes. In this study, we present the generation of novel bioluminescent indicators by modifying the luciferin molecule with an analyte-binding moiety. Specifically, we have successfully developed the first bioluminescent indicator for potassium ions (K+), which are critical electrolytes in biological systems. Our approach involved the design and synthesis of a K+-binding luciferin named potassiorin. Additionally, we engineered a luciferase enzyme called BRIPO (bioluminescent red indicator for potassium) to work synergistically with potassiorin, resulting in optimized K+-dependent bioluminescence responses. Through extensive validation in cell lines, primary neurons, and live mice, we demonstrated the efficacy of this new tool for detecting K+. Our research demonstrates an innovative concept of incorporating sensory moieties into luciferins to modulate luciferase activity. This approach has great potential for developing a wide range of bioluminescent indicators, advancing bioluminescence imaging (BLI), and enabling the study of various analytes in biological systems.


Subject(s)
Luciferases , Luminescent Measurements , Potassium , Potassium/metabolism , Potassium/chemistry , Animals , Luminescent Measurements/methods , Mice , Luciferases/chemistry , Luciferases/metabolism , Humans , Protein Engineering , Luminescent Agents/chemistry , Firefly Luciferin/chemistry , Firefly Luciferin/metabolism
12.
Biosens Bioelectron ; 258: 116351, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38705074

ABSTRACT

Multifunctional single-atom catalysts (SACs) have been extensively investigated as outstanding signal amplifiers in bioanalysis field. Herein, a type of Fe single-atom catalysts with Fe-nitrogen coordination sites in nitrogen-doped carbon (Fe-N/C SACs) was synthesized and demonstrated to possess both catalase and peroxidase-like activity. Utilizing Fe-N/C SACs as dual signal amplifier, an efficient bipolar electrode (BPE)-based electrochemiluminescence (ECL) immunoassay was presented for determination of prostate-specific antigen (PSA). The cathode pole of the BPE-ECL platform modified with Fe-N/C SACs is served as the sensing side and luminol at the anode as signal output side. Fe-N/C SACs could catalyze decomposition of H2O2 via their high catalase-like activity and then increase the Faraday current, which can boost the ECL of luminol due to the electroneutrality in a closed BPE system. Meanwhile, in the presence of the target, glucose oxidase (GOx)-Au NPs-Ab2 was introduced through specific immunoreaction, which catalyzes the formation of H2O2. Subsequently, Fe-N/C SACs with peroxidase-like activity catalyze the reaction of H2O2 and 4-chloro-1-naphthol (4-CN) to generate insoluble precipitates, which hinders electron transfer and then inhibits the ECL at the anode. Thus, dual signal amplification of Fe-N/C SACs was achieved by increasing the initial ECL and inhibiting the ECL in the presence of target. The assay exhibits sensitive detection of PSA linearly from 1.0 pg/mL to 100 ng/mL with a detection limit of 0.62 pg/mL. The work demonstrated a new ECL enhancement strategy of SACs via BPE system and expands the application of SACs in bioanalysis field.


Subject(s)
Biosensing Techniques , Electrochemical Techniques , Electrodes , Hydrogen Peroxide , Iron , Limit of Detection , Luminescent Measurements , Luminol , Prostate-Specific Antigen , Catalysis , Luminescent Measurements/methods , Electrochemical Techniques/methods , Hydrogen Peroxide/chemistry , Hydrogen Peroxide/analysis , Humans , Luminol/chemistry , Prostate-Specific Antigen/analysis , Prostate-Specific Antigen/blood , Iron/chemistry , Glucose Oxidase/chemistry , Immunoassay/methods , Gold/chemistry , Peroxidase/chemistry , Metal Nanoparticles/chemistry , Nitrogen/chemistry , Carbon/chemistry , Naphthols
13.
Biosens Bioelectron ; 259: 116371, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38761742

ABSTRACT

The work was based on N-(4-Aminobutyl)-N-ethylisoluminol (ABEI)-functionalized Fe-MIL-101 and gold nanoparticles (AuNPs) as sensing materials, and an electrochemiluminescence (ECL) aptasensor was constructed for detecting acetamiprid. As a metal-organic framework (MOF) material, Fe-MIL-101, was renowned for its unique three-dimensional network structure and efficient catalytic capability. ABEI, a common ECL reagent, was widely applied. ABEI was introduced into the Fe-MIL-101 structure as a luminescence functionalization reagent to form Fe-MIL-101@ABEI. This approach avoided limitations on the loading capacity of luminescent reagents imposed by modification and encapsulation methods. With character of excellent catalytic activity and ease of bioconjugation, AuNPs offered significant advantages in biosensing. Leveraging the reductive properties of ABEI, AuNPs were reduced around Fe-MIL-101@ABEI, resulting in the modified luminescent functionalized material denoted as Fe-MIL-101@ABEI@AuNPs. An aptamer was employed as a recognition element and was modified accordingly. The aptamer was immobilized on Fe-MIL-101@ABEI@AuNPs through gold-sulfur (Au-S) bonds. After capturing acetamiprid, the aptamer induced a decrease in the ECL signal intensity within the ABEI-hydrogen peroxide (H2O2) system, enabling the quantitative detection of acetamiprid. The aptasensor displayed remarkable stability and repeatability, featured a detection range of 1×10-3-1×102 nM, and had a limit of detection (LOD) of 0.3 pM (S/N=3), which underscored its substantial practical application potential.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Electrochemical Techniques , Gold , Limit of Detection , Luminescent Measurements , Metal Nanoparticles , Metal-Organic Frameworks , Neonicotinoids , Neonicotinoids/analysis , Neonicotinoids/chemistry , Metal-Organic Frameworks/chemistry , Biosensing Techniques/methods , Metal Nanoparticles/chemistry , Gold/chemistry , Aptamers, Nucleotide/chemistry , Luminescent Measurements/methods , Electrochemical Techniques/methods , Vegetables/chemistry , Luminol/chemistry , Luminol/analogs & derivatives , Pesticide Residues/analysis , Pesticide Residues/isolation & purification , Food Contamination/analysis
14.
Biosens Bioelectron ; 259: 116401, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38761743

ABSTRACT

Rapid, portable, and accurate detection tools for monitoring ochratoxin A (OTA) in food are essential for the guarantee of food safety and human health. Herein, as a proof-of-concept, this study proposed a ratiometric bioluminescence immunosensor (RBL-immunosensor) for homogeneous detection of OTA in pepper. The construct of the RBL-immunosensor consists of three components, including the large fragment of the split nanoluciferase (NanoLuc)-tagged nanobody (NLg), the small fragment of the split NanoLuc-tagged mimotope peptide heptamer (MPSm), and the calibrator luciferase (GeNL). The specific nanobody-mimotope peptide interaction between NLg and MPSm induces the reconstitution of the NanoLuc, which catalyzes the Nano-Glo substrate and produces a blue emission peak at 458 nm. Meanwhile, GeNL can produce a green emission peak at 518 nm upon substrate conversion via bioluminescent resonance energy transfer (BRET). Therefore, the concentration of OTA can be linked to the variation of the bioluminescence signal (λ458/λ518) measured by microplate reader and the variation of the blue/green ratio measured by smartphone via the competitive immunoreaction where OTA competes with MPSm to bind NLg. The immunosensor is ready-to-use and works by simply mixing the components in a one-step incubation of 10 min for readout. It has a limit of detection (LOD) of 0.98 ng/mL by a microplate reader and an LOD of 1.89 ng/mL by a smartphone. Good selectivity and accuracy were confirmed for the immunosensor by cross-reaction analysis and recovery experiments. The contents of OTA in 10 commercial pepper powder samples were tested by the RBL-immunosensor and validated by high-performance liquid chromatography. Hence, the ready-to-use RBL-immunosensor was demonstrated as a highly reliable tool for detection of OTA in food.


Subject(s)
Biosensing Techniques , Capsicum , Food Contamination , Limit of Detection , Luminescent Measurements , Ochratoxins , Ochratoxins/analysis , Biosensing Techniques/methods , Food Contamination/analysis , Luminescent Measurements/methods , Immunoassay/methods , Capsicum/chemistry , Humans
15.
Mikrochim Acta ; 191(6): 344, 2024 05 27.
Article in English | MEDLINE | ID: mdl-38802523

ABSTRACT

A molecularly imprinted electrochemiluminescent sensor is developed for the sensitive detection of tetracycline in environmental and food samples. The sensor uses an ionic liquid (i.e. [APMIM]Br) modified graphene-carbon nanotube composite (GMI) material as substrate, a double-layered core-shell metal-organic framework NH2-UiO-66@ZIF-8 (NUZ) loaded bipyridyl ruthenium (NUZ@Ru) as luminescent material, and a molecularly imprinted copolymer of o-phenylenediamine and hydroquinone as recognition element. The ionic liquid-modified graphene-carbon nanotube composite has a favorable three-dimensional structure, high specific surface area, and good hydrophilicity; the core-shell structured metal-organic framework has high stability and plentiful reaction sites for loading; the molecularly imprinted copolymer film has enhanced stability and recognition effect. Hence, the resulting sensor combines the merits of several materials and presents improved performance. Under the optimum detection conditions, it shows a wide linear range of 0.05 µM - 1 mM, a low detection limit of 20 nM, high selectivity, and excellent stability. It has been successfully applied to the detection of tetracycline in different samples.


Subject(s)
Electrochemical Techniques , Limit of Detection , Luminescent Measurements , Metal-Organic Frameworks , Molecularly Imprinted Polymers , Tetracycline , Tetracycline/analysis , Tetracycline/chemistry , Molecularly Imprinted Polymers/chemistry , Metal-Organic Frameworks/chemistry , Luminescent Measurements/methods , Electrochemical Techniques/methods , Graphite/chemistry , Nanotubes, Carbon/chemistry , Food Contamination/analysis , Ionic Liquids/chemistry , Anti-Bacterial Agents/analysis , Anti-Bacterial Agents/chemistry , Water Pollutants, Chemical/analysis , Molecular Imprinting
16.
BMC Biotechnol ; 24(1): 30, 2024 May 08.
Article in English | MEDLINE | ID: mdl-38720310

ABSTRACT

BACKGROUND: Venous thromboembolism (VTE), is a noteworthy complication in individuals with gastric cancer, but the current diagnosis and treatment methods lack accuracy. In this study, we developed a t-PAIC chemiluminescence kit and employed chemiluminescence to detect the tissue plasminogen activator inhibitor complex (t-PAIC), thrombin-antithrombin III complex (TAT), plasmin-α2-plasmin inhibitor complex (PIC) and thrombomodulin (TM), combined with D-dimer and fibrin degradation products (FDP), to investigate their diagnostic potential for venous thrombosis in gastric cancer patients. The study assessed variations in six indicators among gastric cancer patients at different stages. RESULTS: The t-PAIC reagent showed LOD is 1.2 ng/mL and a linear factor R greater than 0.99. The reagents demonstrated accurate results, with all accuracy deviations being within 5%. The intra-batch and inter-batch CVs for the t-PAIC reagent were both within 8%. The correlation coefficient R between this method and Sysmex was 0.979. Gastric cancer patients exhibited elevated levels of TAT, PIC, TM, D-D, FDP compared to the healthy population, while no significant difference was observed in t-PAIC. In the staging of gastric cancer, patients in III-IV stages exhibit higher levels of the six markers compared to those in I-II stages. The ROC curve indicates an enhancement in sensitivity and specificity of the combined diagnosis of four or six indicators. CONCLUSION: Our chemiluminescence assay performs comparably to Sysmex's method and at a reduced cost. The use of multiple markers, including t-PAIC, TM, TAT, PIC, D-D, and FDP, is superior to the use of single markers for diagnosing VTE in patients with malignant tumors. Gastric cancer patients should be screened for the six markers to facilitate proactive prophylaxis, determine the most appropriate treatment timing, ameliorate their prognosis, decrease the occurrence of venous thrombosis and mortality, and extend their survival.


Subject(s)
Luminescent Measurements , Stomach Neoplasms , Humans , Stomach Neoplasms/diagnosis , Male , Middle Aged , Luminescent Measurements/methods , Female , Aged , Antithrombin III/metabolism , Antithrombin III/analysis , Thrombomodulin/blood , Fibrin Fibrinogen Degradation Products/analysis , Fibrin Fibrinogen Degradation Products/metabolism , alpha-2-Antiplasmin/metabolism , alpha-2-Antiplasmin/analysis , Adult , Fibrinolysin/metabolism , Fibrinolysin/analysis , Venous Thromboembolism/diagnosis , Venous Thromboembolism/blood , Peptide Hydrolases
17.
Food Chem ; 452: 139549, 2024 Sep 15.
Article in English | MEDLINE | ID: mdl-38762939

ABSTRACT

The prevention of pollution requires real-time monitoring of cadmium (Cd2+) concentration in the food, as it has a dramatic impact on poultry and can pose a threat to human health. Here, we fabricate a portable workstation integrating a microfluidic chip that facilitates real-time monitoring of Cd2+ levels in real samples by utilizing the Luminol-KMnO4 chemiluminescence (CL) system. Interestingly, Cd2+ can significantly enhance the CL signal, resulting in sensitive detection of Cd2+ in the range of 0-0.18 mg/L with the limit of detection (LOD) of 0.207 µg/L. Furthermore, a remote-controlled unit is integrated into the portable workstation to form a remote-controlled portable workstation (RCPW) performing automated point-of-care testing (POCT) of Cd2+. The as-prepared strategy allows remote control of RCPW to avoid long-distance transportation of samples to achieve real-time target monitoring. Consequently, this system furnishes RCPW for monitoring Cd2+ levels in real samples, thereby holding potential for applications in preventing food pollution.


Subject(s)
Cadmium , Food Contamination , Limit of Detection , Luminescent Measurements , Cadmium/analysis , Food Contamination/analysis , Luminescent Measurements/instrumentation , Luminescent Measurements/methods , Animals , Luminescence , Point-of-Care Testing
18.
Spectrochim Acta A Mol Biomol Spectrosc ; 317: 124399, 2024 Sep 05.
Article in English | MEDLINE | ID: mdl-38718747

ABSTRACT

Herein, a novel sandwich electrochemiluminescence (ECL) aptasensor was developed based on the resonance energy transfer (RET) with iridium complex doped silicate nanoparticles (SiO2@Ir) as energy donor and gold nanoparticles modified TiVC MXene (AuNPs@TiVC) as energy acceptor. Strong anodic ECL signal of SiO2@Ir was obtained through both co-reactant pathway and annihilation pathway. Electrochemical results showed that SiO2@Ir has good electron transfer rate and large specific surface area to immobilize more aptamers. AuNPs@TiVC apparently quenched the ECL signal of SiO2@Ir due to the ECL resonance energy transfer between them. In the presence of kanamycin (KAN), a sandwich type sensor was formed with the aptamer probes as connecters between the donor and the acceptor, resulting in the decrease of ECL intensity. Under the optimal condition, KAN could be sensitively detected in the range of 0.1 pg/mL to 10 ng/mL with a low detection limit of 24.5 fg/mL. The proposed ECL system exhibited satisfactory analytical performance, which can realize the detection of various biological molecules by adopting suitable aptamer.


Subject(s)
Electrochemical Techniques , Gold , Iridium , Kanamycin , Limit of Detection , Metal Nanoparticles , Silicon Dioxide , Silicon Dioxide/chemistry , Gold/chemistry , Metal Nanoparticles/chemistry , Iridium/chemistry , Electrochemical Techniques/methods , Kanamycin/analysis , Luminescent Measurements/methods , Nanospheres/chemistry , Aptamers, Nucleotide/chemistry , Titanium/chemistry , Biosensing Techniques/methods , Energy Transfer
19.
Talanta ; 275: 126156, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38692048

ABSTRACT

The development of simple methods for the isolation and quantification of exosomes in biological samples is important. By using the typical two-dimensional (2D) nanomaterials, graphene oxide (GO), the present work first studied the interaction of liposomes with the nanocomposites formed by adsorbing HRP on the GO surface and found the presence of liposomes led to the release of HRP from the GO surface to the solution phase triggering the luminol-H2O2 chemiluminescence (CL) reaction to emit light. Benefiting from the similarity of exosomes to liposomes in both composition and morphology aspects, the GO-HRP nanocomposites with a mass ratio of 120:1 and 160:1 were employed for the quantitative detection of exosomes in 100-fold diluted serum samples. The whole detection process took about 15 min and as low as 3.2 × 102 particles µL-1 of exosomes could be sensitively detected. In addition to GO-HRP nanocomposites, the CL responses of other nanocomposites obtained from adsorbing HRP on other 2D nanomaterials such as layered MoS2 for exosomes were also tested. MoS2-HRP exhibited similar behavior and the LODs for the detection of exosomes were 5.8 × 102 particles µL-1. The proposed assays were a biomarker-independent quantitative method that achieved the quantification of exosomes in serum samples directly without an isolation process.


Subject(s)
Exosomes , Graphite , Horseradish Peroxidase , Luminescent Measurements , Nanostructures , Exosomes/chemistry , Graphite/chemistry , Horseradish Peroxidase/chemistry , Luminescent Measurements/methods , Adsorption , Humans , Nanostructures/chemistry , Luminol/chemistry , Molybdenum/chemistry , Disulfides/chemistry , Hydrogen Peroxide/chemistry , Limit of Detection , Liposomes/chemistry , Nanocomposites/chemistry
20.
Talanta ; 275: 126114, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38631265

ABSTRACT

Electrochemiluminescence (ECL) is one of the most sensitive techniques in the field of diagnostics. However, they typically require luminescent labeling and electrode surface biological modification, which is a time-consuming and laborious process involving multiple steps and may also lead to low reaction efficiency. Fabricating label/modification-free biosensors has become one of the most attractive parts for simplifying the ECL assays. In this work, the ECL luminophores carbon dots (CDs) were encapsulated in DNA hydrogel in situ by a simple rolling circle amplification (RCA) reaction. Upon binding of the target DNA, active Cas12a induces a collateral cleavage of the hydrogel's ssDNA backbone, resulting in a programmable degradation of the hydrogel and the release of CDs. By directly measuring the released CDs ECL, a simple and rapid label/modification-free detection of the target HPV-16 was realized. It is noted that this method allowed for 0.63 pM HPV-16 DNA detection without any amplification step, and it could take only ∼60 min for a fast test of a human serum sample. These results showed that our label/modification-free ECL biosensor has great potential for use in simple, rapid, and sensitive point-of-care (POC) detection.


Subject(s)
Biosensing Techniques , DNA, Viral , Electrochemical Techniques , Luminescent Measurements , Biosensing Techniques/methods , Luminescent Measurements/methods , Electrochemical Techniques/methods , Humans , DNA, Viral/analysis , DNA, Viral/blood , Bacterial Proteins/chemistry , Endodeoxyribonucleases/chemistry , Carbon/chemistry , Human papillomavirus 16/genetics , Quantum Dots/chemistry , Hydrogels/chemistry , Limit of Detection , DNA/chemistry , DNA/analysis , Nucleic Acid Amplification Techniques/methods , CRISPR-Associated Proteins
SELECTION OF CITATIONS
SEARCH DETAIL
...