Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters











Database
Language
Publication year range
1.
Circ Arrhythm Electrophysiol ; 13(1): e007273, 2020 01.
Article in English | MEDLINE | ID: mdl-31937120

ABSTRACT

BACKGROUND: Atrial fibrillation ablation-related atrial tachycardia (AT) is complex and may demonstrate several forms: anatomic macroreentrant AT (AMAT), non-AMAT, and focal AT. We aimed to elucidate the recurrence rate and mechanisms of atrial fibrillation ablation-related AT recurrence. METHODS: Among 147 patients with ATs treated with the Rhythmia system, 68 (46.3%) had recurrence at mean 4.2 (2.9-11.6) months, and 44 patients received a redo procedure. AT circuits in the first procedure were compared with those in the redo procedure. RESULTS: Although mappable ATs were not observed in 7 patients, 68 ATs were observed in 37 patients during the first procedure: perimitral flutter (PMF) in 26 patients, roof-dependent macroreentrant AT (RMAT) in 18, peritricuspid flutter in 10, non-AMAT in 14, and focal AT in 3. During the redo AT ablation procedure, 54 ATs were observed in 41/44 patients: PMF in 24, RMAT in 14, peritricuspid flutter in 1, non-AMAT in 14, and focal AT in 1. Recurrence of PMF and RMAT was observed in 15 of 26 (57.7%) and 8 of 18 (44.4%) patients, respectively, while peritricuspid flutter did not recur. Neither the same focal AT nor the same non-AMAT were observed except in 1 case with septal scar-related biatrial AT. Epicardial structure-related ATs were involved in 18 of 24 (75.0%) patients in PMF, 4 of 14 (28.6%) in RMAT, and 4 of 14 (28.6%) in non-AMAT. Of 21 patients with a circuit including epicardial structures, 6 patients treated with ethanol infusion in the vein of Marshall did not show any AT recurrence, although 8 of 15 (53.3%) treated with radiofrequency showed AT recurrence (P=0.04). CONCLUSIONS: Although high-resolution mapping may lead to correct diagnosis and appropriate ablation in the first procedure, the recurrence rate is still high. The main mechanism of atrial fibrillation ablation-related AT is the recurrence of PMF and RMAT or non-AMAT different from the first procedure. Epicardial structures (eg, coronary sinus/vein of Marshall system) are often involved, and ethanol infusion in the vein of Marshall may be an additional treatment.


Subject(s)
Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Flutter/diagnostic imaging , Catheter Ablation/adverse effects , Magnetocardiography/methods , Age Distribution , Aged , Analysis of Variance , Atrial Flutter/epidemiology , Atrial Flutter/surgery , Body Surface Potential Mapping/methods , Catheter Ablation/methods , Cohort Studies , Databases, Factual , Female , Follow-Up Studies , Humans , Incidence , Magnetocardiography/adverse effects , Male , Middle Aged , Postoperative Complications/diagnostic imaging , Postoperative Complications/epidemiology , Recurrence , Reoperation/methods , Risk Assessment , Severity of Illness Index , Sex Distribution , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL