Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.644
Filter
1.
J Feline Med Surg ; 26(5): 1098612X241243134, 2024 May.
Article in English | MEDLINE | ID: mdl-38717791

ABSTRACT

CASE SERIES SUMMARY: A total of 13 cases of cats with a caudal mandibular fracture treated with a novel surgical technique using the Ramus Anatomical Plate system were reviewed. Preoperative, immediate postoperative and a minimum of 8 weeks postoperative CT images were required as inclusion criteria. The outcome and complications were determined from clinical data and radiographic follow-up examinations. All cases achieved adequate anatomical reduction, resulting in a functional and atraumatic occlusion postoperatively. No intraoperative complications were reported. Time to voluntary food intake was in the range of 1-25 days. No evidence of disruptions to the implants or screw loosening was observed in the 8-week postoperative CT imaging, with radiographic evidence of complete osseous union in all fractures. The most common postoperative complication was swelling at the surgical site. Two cats had postoperative exophthalmos due to retrobulbar haemorrhage, and one cat exhibited partial wound dehiscence 5 days postoperatively, which resolved with medical management. Longer-term complications included intraoral plate exposure in one cat, which required plate removal 10 months postoperatively. RELEVANCE AND NOVEL INFORMATION: In this case series, rigid internal fixation of caudal mandibular fractures using the Ramus Anatomical Plate osteosynthesis system was associated with a minimal complication rate, and satisfactory radiographic and clinical outcomes. The reported outcomes of this novel technique are favourable when compared with previous techniques described for the management of these fracture types.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Mandibular Fractures , Cats/injuries , Animals , Bone Plates/veterinary , Fracture Fixation, Internal/veterinary , Fracture Fixation, Internal/methods , Mandibular Fractures/veterinary , Mandibular Fractures/surgery , Male , Female , Treatment Outcome , Postoperative Complications/veterinary , Tomography, X-Ray Computed/veterinary , Cat Diseases/surgery
2.
Cir Cir ; 92(2): 211-218, 2024.
Article in English | MEDLINE | ID: mdl-38782385

ABSTRACT

OBJECTIVES: The aim of the study was to investigate the clinical effect of stainless-steel wire fixation on the early mouth-opening movement of an intracapsular fracture involving the condylar process. MATERIALS AND METHODS: In this study, patients who underwent mandibular condylar intracapsular fracture surgery in our hospital from 2012 to 2020 were selected as research subjects. A total of 44 patients received steel wire internal fixation treatment, 32 patients received titanium plate-and-nail rigid internal fixation, and 28 patients underwent conservative non-surgical treatment. RESULTS: For the patients in the stainless-steel wire group, the degree of mouth opening reached normal levels of 3.7 cm approximately 10 days after surgery. The recovery time for the patients in the titanium plate-and-nail rigid internal-fixation group was 21 days, while the patients in the conservative treatment group needed 60 days to recover. CONCLUSION: The treatment of fixation with a stainless-steel wire for intracapsular condylar fracture reduced the time taken to perform mouth-opening exercises and improved the recovery rate of patients.


OBJETIVO: Explorar el efecto clínico de la fijación de alambre de acero inoxidable en el movimiento temprano de apertura de la boca en la fractura interna del cóndilo. MÉTODO: Este estudio seleccionó a pacientes que se sometieron a cirugía de fractura intracapsular de cóndilo en nuestro hospital de 2012 a 2020 como sujetos de investigación. Un total de 44 pacientes recibieron tratamiento de fijación interna de alambre de acero, 32 recibieron placa de titanio y fijación interna con clavos, y 28 recibieron tratamiento conservador no quirúrgico. RESULTADOS: En los pacientes del grupo de alambre de acero inoxidable, alrededor de 10 días después de la cirugía el grado de apertura de la boca alcanzó un valor normal de 3.7 cm. El tiempo de recuperación de los pacientes en el grupo de fijación interna con clavos y placa de titanio fue de 21 días, mientras que los pacientes en el grupo de tratamiento conservador tardaron 60 días en recuperarse. CONCLUSIONES: La fijación con alambre de acero inoxidable para el tratamiento de la fractura intracapsular del cóndilo acorta el tiempo hasta la apertura de la boca y mejora la tasa de recuperación de los pacientes.


Subject(s)
Bone Plates , Bone Wires , Fracture Fixation, Internal , Mandibular Condyle , Mandibular Fractures , Stainless Steel , Humans , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Mandibular Fractures/surgery , Mandibular Condyle/injuries , Mandibular Condyle/surgery , Male , Female , Adult , Middle Aged , Titanium , Range of Motion, Articular , Bone Nails , Young Adult , Retrospective Studies
3.
J Int Med Res ; 52(5): 3000605241257446, 2024 May.
Article in English | MEDLINE | ID: mdl-38819092

ABSTRACT

Isolated coronoid process fractures are uncommon, and iatrogenic isolated fractures are extremely rare. This case describes a displaced fracture of an isolated coronoid process thought to be due to excessive force applied by a dentist that had been overlooked and left untreated for about a month. The patient was a woman in her late 50's and she had undergone a molar extraction. Her dentist had confused her symptoms of trismus, pain, and facial oedema with the complex tooth extraction procedure. Following a cone-beam computed tomography (CBCT) scan we showed that the mandibular coronoid process on her right side had suffered a longitudinal fracture, and the fractured fragment had rotated upwards and inwards. Following successful surgical elimination of the fragmented coronoid process, the patient received targeted physiotherapy sessions that yielded excellent results. At the five-month follow-up, the ability of the patient to open her mouth had improved enormously, and her facial appearance almost recovered to its original state.


Subject(s)
Cone-Beam Computed Tomography , Tooth Extraction , Humans , Female , Tooth Extraction/adverse effects , Middle Aged , Molar/surgery , Molar/injuries , Mandibular Fractures/surgery , Mandibular Fractures/diagnostic imaging , Mandible/surgery , Mandible/diagnostic imaging , Mandible/pathology
4.
Sci Rep ; 14(1): 11795, 2024 05 23.
Article in English | MEDLINE | ID: mdl-38782942

ABSTRACT

The clinical finite element analysis (FEA) application in maxillofacial surgery for mandibular fracture is limited due to the lack of a validated FEA model. Therefore, this study aims to develop a validated FEA model for mandibular fracture treatment, by assessing non-comminuted mandibular fracture fixation. FEA models were created for mandibles with single simple symphysis, parasymphysis, and angle fractures; fixated with 2.0 mm 4-hole titanium miniplates located at three different configurations with clinically known differences in stability, namely: superior border, inferior border, and two plate combinations. The FEA models were validated with series of Synbone polymeric mandible mechanical testing (PMMT) using a mechanical test bench with an identical test set-up. The first outcome was that the current understanding of stable simple mandibular fracture fixation was reproducible in both the FEA and PMMT. Optimal fracture stability was achieved with the two plate combination, followed by superior border, and then inferior border plating. Second, the FEA and the PMMT findings were consistent and comparable (a total displacement difference of 1.13 mm). In conclusion, the FEA and the PMMT outcomes were similar, and hence suitable for simple mandibular fracture treatment analyses. The FEA model can possibly be applied for non-routine complex mandibular fracture management.


Subject(s)
Bone Plates , Finite Element Analysis , Fracture Fixation, Internal , Mandible , Mandibular Fractures , Mandibular Fractures/surgery , Humans , Mandible/surgery , Mandible/physiology , Biomechanical Phenomena , Fracture Fixation, Internal/methods , Mechanical Tests , Titanium , Stress, Mechanical , Polymers/chemistry
5.
J Craniofac Surg ; 35(4): 1120-1124, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38713082

ABSTRACT

PURPOSE: The training and preferences of surgeons influence the type of surgical treatment for mandibular fractures. This multicentre prospective study analyzed the current treatment strategies and outcomes for mandibular fractures with open reduction and internal fixation (ORIF). MATERIAL AND METHODS: This prospective study included patients aged ≥16 years who underwent ORIF for mandibular fractures in 12 European maxillofacial centers. Age, sex, pretrauma dental status, fracture cause, site and type, associated facial fractures, surgical approach, plate number and thickness (≤1.4 or ≥1.5 mm), duration of postoperative maxillomandibular fixation, occlusal and infective complications at 6 weeks and 3 months, and revision surgeries were recorded. RESULTS: Between May 1, 2021 and April 30, 2022, 425 patients (194 single, 182 double, and 49 triple mandibular fractures) underwent ORIF for 1 or more fractures. Rigid osteosynthesis was performed for 74% of fractures and was significantly associated with displaced ( P =0.01) and comminuted ( P =0.03) fractures and with the number of nonsurgically treated fracture sites ( P =0.002). The angle was the only site associated with nonrigid osteosynthesis ( P <0.001). Malocclusions (5.6%) and infective complications (5.4%) were not associated with osteosynthesis type. CONCLUSION: Rigid osteosynthesis was the most frequently performed treatment at all fracture sites, except the mandibular angle, and was significantly associated with displaced and comminuted fractures and the number of nonsurgically treated fracture sites. No significant differences were observed regarding postoperative malocclusion or infections among osteosynthesis types.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Mandibular Fractures , Humans , Mandibular Fractures/surgery , Prospective Studies , Male , Female , Fracture Fixation, Internal/methods , Adult , Middle Aged , Europe , Adolescent , Aged , Postoperative Complications , Open Fracture Reduction , Young Adult , Treatment Outcome , Aged, 80 and over
6.
Gen Dent ; 72(3): 50-55, 2024.
Article in English | MEDLINE | ID: mdl-38640006

ABSTRACT

The objective of this retrospective study was to assess the bone quality of healing mandibular fracture sites by measuring the Hounsfield units (HU) on computed tomographic (CT) images obtained presurgery and postsurgery in patients treated with rigid internal fixation (RIF). The HU values of healing fracture sites were compared to those of corresponding nonfractured (control) sites on the opposing side and cervical vertebrae sites in the same patients. In total, 31 patients with 45 mandibular fractures treated with RIF underwent presurgical and postsurgical CT examinations. The scans performed after surgery (1, 3, 6, 12, or 18 months) were taken only when there was a need for radiographic evaluation due to a complaint of discomfort from the patient or when the surgeon needed to verify the postsurgical outcome, and each patient underwent only a single postsurgical CT. At the presurgical CT examination, the HU values were lower in the fracture sites than in the control sites. At 3 months postsurgery, the HU values in the fracture sites had increased as the mandibular bone healed. At 6 months postsurgery, the HU values in the fracture sites were higher than those of the control sites. At 12 and 18 months postsurgery, the HU values of both sites were similar. The HU values of the cervical vertebrae remained constant with time. These results suggest that, in patients who have been treated with RIF for mandibular bone fracture, HU values measured by CT vary across time, expressing the physiologic bone healing process.


Subject(s)
Bone Density , Mandibular Fractures , Humans , Retrospective Studies , Bone Density/physiology , Mandibular Fractures/diagnostic imaging , Mandibular Fractures/surgery , Tomography, X-Ray Computed/methods , Tomography
8.
Br J Oral Maxillofac Surg ; 62(4): 349-360, 2024 May.
Article in English | MEDLINE | ID: mdl-38604919

ABSTRACT

This review examines the prevailing modalities for fractures of the anterior mandible, which represent a significant proportion of the maxillofacial injuries commonly treated by oral and maxillofacial surgeons. The article traces the historical shift from conservative techniques to the dominant management strategies of open reduction and fixation. Encompassing a range of studies, the review, in accordance with PRISMA 2020 recommendations, meticulously examines various fixation methods, assessing their efficacy in achieving stability of fracture, early healing, and mobilisation. The comparison of these methods highlights their unique advantages and limitations, and demonstrates the need for more nuanced and precise approaches. The review emphasises evidence-based methodology in the management of anterior mandibular fractures (AMF), highlighting the benefits offered by innovative techniques such as 3D miniplates. It also acknowledges the advantages provided by older fixation devices such as lag screws. The importance of postoperative outcomes and the need for tailored treatment strategies are recognised, considering the complex nature of these fractures.


Subject(s)
Fracture Fixation, Internal , Mandibular Fractures , Humans , Bone Plates , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Mandibular Fractures/surgery , Mandibular Fractures/therapy
9.
J Craniomaxillofac Surg ; 52(5): 636-643, 2024 May.
Article in English | MEDLINE | ID: mdl-38580559

ABSTRACT

The purpose of this study was to elucidate the effects of mandibular anatomy and osteotomy technique on lingual fracture patterns in SSRO. The predictor variables were: length of horizontal medial osteotomy; type of border osteotomy; buccolingual width; and vertical length of the basal cortex. The outcome variable was the type of lingual split pattern. This was categorized into four types according to a lingual split scale (LSS): LSS 1, true Hunsuck; LSS 2, fracture line to posterior border of the ramus; LSS 3, through to mandibular canal; LSS 4, unfavorable fracture pattern. Data were analyzed using analysis of variance and the Pearson χ2 test. Values of p < 0.05 were considered statistically significant. The study sample comprised 312 lingual split patterns in 156 patients. The most common type of lingual split pattern was LSS 1 (n = 204). There was a significant relationship between inferior border osteotomy type and LSS type (p = 0.001). Whilst LSS 1 was the most common among all border osteotomy types. LSS 4 was most frequently observed in cases where the lower border osteotomy remained in the buccal surface. According to the results of this study, the likelihood of an unfavorable split pattern increases when the lower border osteotomy remains in the buccal surface.


Subject(s)
Osteotomy, Sagittal Split Ramus , Humans , Osteotomy, Sagittal Split Ramus/methods , Male , Female , Adult , Mandible/surgery , Young Adult , Adolescent , Mandibular Fractures/surgery , Middle Aged , Retrospective Studies
10.
J Craniomaxillofac Surg ; 52(5): 622-629, 2024 May.
Article in English | MEDLINE | ID: mdl-38582680

ABSTRACT

Fractures of the mandibular condyle account for a significant proportion of mandibular fractures. The specific functional loads require particular specifications for the implant design used for open reduction and internal fixation of such fractures. The clinical and radiographic outcomes in patients treated using a single rhombic 3D condylar fracture plate for open reduction and internal fixation at a single institution, and who fulfilled the inclusion and exclusion criteria, are presented. The primary outcome variables were: occlusion, maximum interincisal distance and mandibular excursion at 1, 3, and 6 months postoperatively, and radiographic measurements for mandibular height and gonion angle. In total, 263 patients were included, of whom 173 (65.8%) were male and 90 (34.2%) female. The mean age was 40.4 ± 18.9 years. There was satisfactory occlusion in 98.9% of patients at the 6-month follow-up, and a significant improvement in all parameters for mandibular excursion (p < 0.001), with a reduced ramus height and an increase in the gonion angle on the fractured side. Excellent clinical and radiographic results were achieved using the rhombic-shaped implant, deeming it appropriate for the osteosynthesis of mandibular condyle fractures.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Mandibular Condyle , Mandibular Fractures , Open Fracture Reduction , Humans , Mandibular Fractures/surgery , Mandibular Fractures/diagnostic imaging , Female , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Mandibular Condyle/injuries , Mandibular Condyle/surgery , Mandibular Condyle/diagnostic imaging , Male , Adult , Retrospective Studies , Middle Aged , Open Fracture Reduction/methods , Treatment Outcome , Young Adult , Adolescent , Aged
11.
J Craniomaxillofac Surg ; 52(4): 397-405, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38458893

ABSTRACT

This study aimed to evaluate the feasibility and accuracy of a combined virtual surgical planning (VPS) and short-segment drilling guides (SSDGs) workflow for the treatment of complex mandibular fractures. Consecutive patients with complex mandibular fractures underwent treatment using the VPS and SSDGs workflow from August 2020 to April 2022. Various mandibular landmarks were compared between the preoperative virtual surgical plan and postoperative data, including condylar distance (CoD), mandibular angle width (GoL-GoR), GoMeGo angle (∠GoL-Me-GoR), the difference in mandibular angles between the left and right sides (Δ∠Co-Go-Me), and the difference in length between the left and right mandibular body (ΔGo-Me). Additionally, preoperative preparation time and surgical duration were retrospectively analyzed and compared to conventional surgery. All 14 consecutive patients with complex mandibular fractures achieved successful reduction using the VPS and SSDGs workflow. Three-dimensional comparison revealed a mean deviation distance of 0.91 ± 0.50 mm and a root-mean-square deviation of 1.75 ± 0.47 mm between the preoperative designed mandible model and the postoperative mandible model. The percentage of points with deviation distances less than 2 mm, 1 mm, and 0.5 mm between preoperative and postoperative models were 78.47 ± 8.87 %, 60.02 ± 14.28 %, and 38.64 ± 15.48 %, respectively. There were no significant differences observed in CoD, GoL-GoR, ∠GoL-Me-GoR, Δ∠Co-Go-Me, and ΔGo-Me between preoperative virtual surgical planning and postoperative measurements. Furthermore, no significant differences were found in the injury-to-surgery interval, admission-to-surgery interval, and surgical duration between the workflow and conventional surgery. The combined VPS and SSDGs workflow proved to be an accurate and feasible method for treating complex mandibular fractures. It offers advantages such as minimal preoperative preparation time and the ability to precise transfer screw positions of the pre-bent reconstruction plate during surgery. This approach is particularly suitable for managing complex mandibular fractures.


Subject(s)
Mandibular Fractures , Mandibular Reconstruction , Surgery, Computer-Assisted , Humans , Mandibular Fractures/diagnostic imaging , Mandibular Fractures/surgery , Retrospective Studies , Tomography, X-Ray Computed/methods , Surgery, Computer-Assisted/methods , Mandible/surgery , Mandibular Reconstruction/methods
12.
J Plast Reconstr Aesthet Surg ; 92: 79-86, 2024 May.
Article in English | MEDLINE | ID: mdl-38507862

ABSTRACT

BACKGROUND: Open reduction with internal fixation is the preferred treatment option for displaced facial bone fractures. The superior mechanical properties of metallic plates have made them the most widely used material in existing bone fixation systems. However, after the healing period, these permanent plates can cause various problems. Alternative bioresorbable materials are being investigated to reduce these potential problems. This study compares bone stability and viability by using graphene oxide (GO)-doped poly-lactic-co-glycolic acid (PLGA) nanofiber plates and titanium plates for rats with fractured mandibles. MATERIALS AND METHODS: The study included 20 male Sprague-Dawley rats, divided into four groups: a control group (Group I), a mandibular fracture group with no additional application (Group II), a mandibular fracture group repaired with titanium plates (Group III), and a mandibular fracture group repaired with GO-PLGA plates (Group IV). After 2 months, all of the rats were euthanized. A bone compression test was performed to assess bone stability, and a histological examination was performed to evaluate bone healing. RESULTS: The osteocyte lacunae, Haversian ducts, canaliculi, and vascular structures of Group IV were found to be higher. In the compression test, vertical compression was applied to the bone axis, and Group IV had a higher maximum load and maximum stretch. GO-PLGA plates were found to be statistically superior to titanium plates in terms of both bone stability and bone healing (p < 0.05). CONCLUSIONS: The present study found that GO-PLGA plates are more effective than titanium plates for the treatment of mandibular corpus fractures.


Subject(s)
Absorbable Implants , Bone Plates , Fracture Fixation, Internal , Graphite , Mandibular Fractures , Nanofibers , Polylactic Acid-Polyglycolic Acid Copolymer , Rats, Sprague-Dawley , Titanium , Animals , Male , Rats , Mandibular Fractures/surgery , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fracture Healing
13.
J Plast Reconstr Aesthet Surg ; 92: 151-176, 2024 May.
Article in English | MEDLINE | ID: mdl-38520780

ABSTRACT

PURPOSE: Currently, there are several methods of achieving maxillomandibular fixation (MMF), each with its unique operative considerations and subsequent patient outcomes and complications. In this study, we reviewed the literature to evaluate and compare all MMF methods. METHODS: A systematic review of all MMF types was conducted and post-operative outcome data were analyzed and compared among the different types. Conventional Erich arch bars were compared to hybrid arch bars, MMF screws, and eyelet interdental wiring. A random-effects meta-analysis was used to determine the mean differences, and 95% confidence intervals (CIs) with a statistical significance of P < 0.05. RESULTS: Among the 4234 articles identified, 24 were included, and 17 were meta-analyzed. Time to achieve MMF (-43.38 min; 95% CI, -58.20 to -28.56; P < 0.001), total operative time (-30.33 min; 95% CI, -61.05 to 0.39; P = 0.05), incidence of wire puncture injuries and glove perforations (0.11; 95% CI, 0.04 to 0.30; P < 0.001), and incidence of poor oral hygiene (0.08; 95% CI, 0.02 to 0.28; P < 0.001) were lower for alternative MMF interventions compared to those of the conventional Erich arch bars. CONCLUSIONS: Alternative MMF methods required shorter operative time to achieve MMF and demonstrated other increased efficiencies of practice such as shorter total operative time and decreased glove perforations, when compared to conventional Erich arch bars. If a patient is a candidate for MMF, the presented alternative MMF techniques should be considered depending on the clinical context and availability of institutional resources.


Subject(s)
Jaw Fixation Techniques , Postoperative Complications , Humans , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Jaw Fixation Techniques/instrumentation , Mandibular Fractures/surgery , Treatment Outcome , Operative Time
14.
J Craniofac Surg ; 35(4): 1289-1291, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38483294

ABSTRACT

OBJECTIVE: An improved method of treating inwardly dislocated mandibular extracapsular condylar fracture-three times titanium plate gradual fixation method was introduced, and the clinical efficacy of this method was evaluated. METHODS: Twenty patients with extracapsular condylar fractures who underwent surgical treatment using the three times titanium plate gradual restoration and fixation method in the Department of Oral Craniomaxillofacial Surgery of the Ninth People's Hospital of Shanghai from November 2020 to June 2023 were selected as the study subjects. RESULTS: After condylar restoration 22 sides reached healing and 1 side was basically healed; in 3 months after the operation, the degree of opening the mouth and the type of the opening of the mouth reached normal, and 1 case had mildly poor occlusion, which required to be further adjusted through orthodontics, and there was no temporomandibular function disorder or facial nerve function damage. CONCLUSION: Three times of gradual fixation with a titanium plate can make the condylar process achieve precise and stable repositioning, and make the surgical process orderly, and it is a kind of reliable fixation method for extracapsular condylar fractures.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Mandibular Condyle , Mandibular Fractures , Titanium , Humans , Mandibular Fractures/surgery , Mandibular Condyle/injuries , Mandibular Condyle/surgery , Male , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Female , Adult , Middle Aged , Treatment Outcome , Young Adult , Adolescent
15.
J Oral Maxillofac Surg ; 82(4): 449-460, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38336352

ABSTRACT

PURPOSE: This study investigates whether the intraoral approach to mandibular open reduction and internal fixation, through exposure to the oral cavity's microbiome, results in higher infection rates compared to the extraoral approach, thus addressing a critical public health concern, potentially offering an opportunity to reduce health-care costs, and aiming to guide effective clinical practice. METHODS: In this systematic review with meta-analyses, a review of the literature was conducted in accordance with the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines. A comprehensive literature search was conducted using Embase and PubMed for articles published between 1989 and 2023. Inclusion criteria targeted studies on open reduction and internal fixation mandibular fractures comparing intraoral and extraoral approaches and reporting infection rates. Exclusion criteria eliminated non-English articles, case reports, and studies with insufficient approach-specific data. The primary outcome was the postoperative infection rate, with surgical approach as the predictor. Covariates such as age, sex, diabetes, and smoking status were included when reported. Data were analyzed using R software, employing random-effects models due to anticipated heterogeneity (I2 statistics). RESULTS: From 61 studies, 11 provided direct comparisons involving 1,317 patients-937 intraoral and 380 extraoral. Infection rates were 5.9% for intraoral and 10% for extraoral approaches. Pooled relative risk was 0.94 [95% confidence interval, 0.63, 1.39], suggesting no significant risk difference. Prevalence of infections was estimated at 9% for intraoral and 6.1% for extraoral procedures, with significant heterogeneity (I2 = 84% for intraoral and 56% for extraoral). CONCLUSION: Our meta-analysis found no significant difference in infection rates between the two approaches. There is opportunity to expand on reporting complication rates comparing the various approaches to mandibular fixation. Until these data are presented, surgeon preference may dictate the operative approach to expose the mandible for reduction and fixation.


Subject(s)
Mandibular Fractures , Humans , Mandibular Fractures/surgery , Mandible/surgery , Fracture Fixation, Internal/methods , Open Fracture Reduction , Postoperative Complications
16.
J Oral Maxillofac Surg ; 82(5): 538-545, 2024 May.
Article in English | MEDLINE | ID: mdl-38373697

ABSTRACT

BACKGROUND: Poorly controlled postoperative pain results in prolonged length of stay (LOS). The use of liposome bupivacaine injectable suspension (LB) for postoperative pain control is a relatively recent practice. PURPOSE: The purpose of this study was to investigate the following. In patients undergoing open reduction and internal fixation of mandibular fracture(s), does the use of LB reduce LOS compared with regular bupivacaine? STUDY DESIGN, SETTING, SAMPLE: We implemented a retrospective cohort study of consecutive patients with mandibular fracture(s) presented to Grady Memorial Hospital in Atlanta, GA, from January 2021 to January 2022. Adult patients diagnosed with 1 or more isolated mandibular fracture(s) and treated by open reduction and internal fixation were included. We excluded patients with non-isolated mandibular fracture(s), isolated condyle, infected, previously treated fractures, and documented allergy to amide local anesthetics and/or its preservatives. PREDICTOR/EXPOSURE/INDEPENDENT VARIABLE: Primary predictor variable was local anesthetic (regular bupivacaine alone or LB/regular bupivacaine). MAIN OUTCOME VARIABLE(S): Primary outcome variable was LOS, defined as the number of days from surgical procedure until discharge. Secondary outcome variables were number of opioid prescription refill(s) and postoperative pain at discharge, determined with visual analogue scale. COVARIATES: The covariates were Demographics, American Society of Anesthesiologists classification, smoking, alcohol exposure, illicit drug use, etiology, location, laterality, number of fracture(s), surgical approach, and method of maxillomandibular fixation. ANALYSES: Univariate and bivariate analyses were calculated. Statistical significance was P < .05. RESULTS: Sixty-two subjects met the inclusion criteria (31 subjects in each group). The mean ages in LB/regular bupivacaine and regular bupivacaine alone groups were 33.3 (±12) and 35.1 (±15.6), respectively (P = .94), the mean LOS in days was 0.23 (±0.44) in LB/regular bupivacaine and 1.48 (±1.77) in regular bupivacaine alone (P= < .001), and the mean VAS pain scores for LB/regular bupivacaine and regular bupivacaine alone groups were 0.53 (±1.07) and 1.87 (±2.66), respectively (P = .02). Mean number of opioid prescription refill(s) was 0 in LB/regular bupivacaine and 1 in regular bupivacaine alone group, respectively (P = .01). CONCLUSION AND RELEVANCE: The use of LB/regular bupivacaine for mandibular fracture(s) results in decrease in LOS and number of opioid refills compared to regular bupivacaine alone.


Subject(s)
Anesthetics, Local , Bupivacaine , Fracture Fixation, Internal , Length of Stay , Liposomes , Mandibular Fractures , Pain, Postoperative , Humans , Bupivacaine/administration & dosage , Mandibular Fractures/surgery , Retrospective Studies , Male , Female , Anesthetics, Local/administration & dosage , Pain, Postoperative/drug therapy , Pain, Postoperative/prevention & control , Adult , Fracture Fixation, Internal/methods , Middle Aged , Open Fracture Reduction/methods , Pain Measurement
17.
J Craniofac Surg ; 35(4): e316-e321, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38421202

ABSTRACT

OBJECTIVE: The decision to retain or extract teeth in the line of mandibular fractures has been a subject of debate in much of the scientific literature, and there is a need for further evidence to clear this issue. Thus, the aim of this study was to investigate both the positive and negative effects of teeth in the line of mandibular fractures provide more evidence in this field, as well as take into consideration patients' quality of life after the surgery. METHODS: Patients after trauma with teeth in the line of mandibular fractures were included in this study. Open reduction and rigid internal fixation, elastic intermaxillary reduction were expected to achieve a satisfactory occlusion and/or anatomical reduction in the fragments as assessed by orthopantomogram, computed tomography scans, and clinical examination. The remaining cases had maxillomandibular fixation (MMF) with an arch bar and bridle wire. All the patients included in this study will take the Visual Analog Scale score evaluation before and after surgery subjectively to further verify the impact on their life qualify, as well as the further treatment needed. RESULTS: A total of 78 patients with teeth in the line of mandibular fractures were included in this study. Open reduction and rigid internal fixation was used in 37 patients, whereas another 35 patients accepted elastic intermaxillary reduction. Six cases underwent MMF. The number of involved teeth was 83. Three of the 83 teeth involved in the fracture lines healed with complications. In the cases where the teeth had been removed before fracture treatment, or in cases of delayed extractions, no complications were noted. The majority of the patients felt good about the whole treatment, however, 4 in the MMF group complained about worry about their oral health due to MMF leading to mouth open limitation. CONCLUSION: The factors that should be considered for removal include the condition of the teeth and alveolar bone, the timing and the type of treatment, as well as the patients' desire, if possible. This is an individual-based decision that needs to consider more objective and subjective potential risks to avoid complications.


Subject(s)
Fracture Fixation, Internal , Mandibular Fractures , Quality of Life , Radiography, Panoramic , Humans , Mandibular Fractures/surgery , Mandibular Fractures/diagnostic imaging , Male , Female , Fracture Fixation, Internal/methods , Adult , Tomography, X-Ray Computed , Jaw Fixation Techniques , Tooth Extraction , Middle Aged , Treatment Outcome , Tooth Injuries , Open Fracture Reduction/methods
18.
J Craniomaxillofac Surg ; 52(3): 279-282, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38320919

ABSTRACT

This retrospective analysis aimed to investigate the necessity of removing the wisdom tooth in cases of angle fractures of the mandible. The study retrieved 595 mandible fractures from January 2006 to December 2021 through the Hospital Inpatient Enquiry System, of which 303 involved a fracture through the angle of the mandible, including the wisdom tooth socket. Of these, 203 (66.9%) underwent open reduction and internal fixation with retention of the third molar. The authors found that only four (2%) patients returned for the removal of plates and the retained third molar during the follow-up period. Therefore, the authors concluded that wisdom teeth removal should remain an exception during open reduction and internal fixation of mandibular angle fractures unless they hinder fracture reduction, pose a potential infection risk, or interfere with occlusal stability.


Subject(s)
Mandibular Fractures , Tooth, Impacted , Humans , Mandibular Fractures/surgery , Molar, Third/surgery , Retrospective Studies , Mandible/surgery , Fracture Fixation , Tooth Extraction , Tooth, Impacted/surgery
19.
Oral Maxillofac Surg ; 28(2): 839-847, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38286958

ABSTRACT

PURPOSE: To clarify reasons for infections, surgical techniques, and occurrence of postoperative surgical site complications in infected mandibular fractures. METHODS: Patients with clinically infected mandibular fracture of the dentate part without preceding surgery were studied retrospectively. Clinical infection was defined to occur if pus, abscess, or a fistula in the fracture area was present. Patient-, fracture-, and surgery-related variables were evaluated, and predictors for postoperative complications were analysed. RESULTS: Of 908 patients with surgically treated fracture in the dentate part of the mandible, 41 had infected fracture at the time of surgery (4.5%). Of these patients, 46.3% were alcohol or drug abusers. Median delay from injury to surgery was 9 days. Patient-related factors were the most common cause for delayed surgery (n = 30, 73.2%), followed by missed diagnosis by a health care professional (n = 8, 19.5%). Twenty-two fractures were treated via extraoral approach (53.7%) and the remaining 19 intraorally (46.3%). Postoperative surgical site complications were found in 13 patients (31.7%), with recurrent surgical site infections predominating. Notable differences between total complication rates between intraoral and extraoral approaches were not detected. Secondary osteosynthesis for non-union was conducted for one patient treated intraorally. CONCLUSIONS: Postoperative surgical site complications are common after treatment of infected mandibular fractures, and these occur despite the chosen surgical approach. Infected mandibular fractures heal mainly without bone grafting, and non-union is a rare complication. Due to the high complication rate, careful perioperative and postoperative care is required for these patients.


Subject(s)
Mandibular Fractures , Surgical Wound Infection , Humans , Mandibular Fractures/surgery , Adult , Male , Female , Surgical Wound Infection/etiology , Middle Aged , Retrospective Studies , Adolescent , Aged , Young Adult , Fracture Fixation, Internal , Postoperative Complications/etiology , Time-to-Treatment , Substance-Related Disorders/complications , Delayed Diagnosis
20.
J Oral Maxillofac Surg ; 82(1): 47-55, 2024 01.
Article in English | MEDLINE | ID: mdl-38164998

ABSTRACT

BACKGROUND: Scientific evidence of nonsurgical site-related complications in mandibular fracture patients is limited. PURPOSE: The purpose was to measure the frequency of nonsurgical site complications in patients with mandible fractures, describe the types of complications, and identify the risk factors associated with these complications. STUDY DESIGN, SETTING, SAMPLE: A retrospective cohort study was conducted at the Helsinki University hospital between 2018 and 2021. Patients undergoing surgery with open reduction and internal fixation of mandibular fracture(s) were evaluated. Patients under 16 years of age were excluded. PREDICTOR VARIABLE: Primary predictor variable was age. Patient-related predictor variables were sex, long-term disease(s), smoking, and alcohol and/or drug abuse. Injury and fracture-related variables were injury mechanism, type and site of facture, combined craniofacial fracture(s), and associated injury(s). MAIN OUTCOME VARIABLE(S): The primary outcome variable was nonsurgical site-related postoperative complication. The secondary outcome variable was type of complication. COVARIATES: Not applicable. ANALYSES: The main outcome variable was cross tabulated for pairwise comparisons with predictor variables. Multivariate logistic regression was performed for statistically significant (P < .05) variables. RESULTS: The data included 314 patients (age range: 16 to 89 years; mean age: 38 years old; median age: 33 years old); most (78.3%) were men. Nonsurgical site-related postoperative complications occurred in 6.7% of patients. The most common complication type was pulmonary complication (36.0%), followed by urinary complication (20.0%) and general infection (16.0%). Nonsurgical site-related postoperative complications were most likely to occur in patients who were elderly (adjusted odds ratio [aOR] 5.55; 95% CI 1.92 to 16.21; P = .002), had combined craniofacial fractures (aOR 2.92; 95% CI 1.06 to 8.03; P = .038), and abused alcohol or drugs (aOR 4.51; 95% CI 1.70 to 11.96; P = .003). Pulmonary complications occurred more often in elderly patients, whereas urinary complications were more common in younger patients. CONCLUSIONS AND RELEVANCE: The types of nonsurgical site complications in mandibular fracture patients increase and vary according to the patient's age. Awareness of possible complications related to different age groups helps anticipate and identify these in clinical work, and to consider the overall treatment of the patient beyond the fracture.


Subject(s)
Mandibular Fractures , Male , Humans , Aged , Adult , Adolescent , Young Adult , Middle Aged , Aged, 80 and over , Female , Mandibular Fractures/surgery , Mandibular Fractures/etiology , Retrospective Studies , Treatment Outcome , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Fracture Fixation, Internal/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...