Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.286
Filter
1.
Sci Rep ; 14(1): 13019, 2024 06 06.
Article in English | MEDLINE | ID: mdl-38844492

ABSTRACT

In recent years functional multiphoton (MP) imaging of vital mouse tissues and stimulation emission depletion (STED) imaging of optically cleared tissues allowed new insights into kidney biology. Here, we present a novel workflow where MP imaging of calcium signals can be combined with super-resolved STED imaging for morphological analysis of the slit diaphragm (SD) within the same glomerulus. Mice expressing the calcium indicator GCaMP3 in podocytes served as healthy controls or were challenged with two different doses of nephrotoxic serum (NTS). NTS induced glomerular damage in a dose dependent manner measured by shortening of SD length. In acute kidney slices (AKS) intracellular calcium levels increased upon disease but showed a high variation between glomeruli. We could not find a clear correlation between intracellular calcium levels and SD length in the same glomerulus. Remarkably, analysis of the SD morphology of glomeruli selected during MP calcium imaging revealed a higher percentage of completely disrupted SD architecture than estimated by STED imaging alone. Our novel co-imaging protocol is applicable to a broad range of research questions. It can be used with different tissues and is compatible with diverse reporters and target proteins.


Subject(s)
Calcium , Kidney Glomerulus , Microscopy, Fluorescence, Multiphoton , Podocytes , Animals , Podocytes/metabolism , Calcium/metabolism , Mice , Kidney Glomerulus/metabolism , Kidney Glomerulus/ultrastructure , Microscopy, Fluorescence, Multiphoton/methods
2.
Sci Rep ; 14(1): 10954, 2024 05 13.
Article in English | MEDLINE | ID: mdl-38740797

ABSTRACT

Temporal focusing two-photon microscopy has been utilized for high-resolution imaging of neuronal and synaptic structures across volumes spanning hundreds of microns in vivo. However, a limitation of temporal focusing is the rapid degradation of the signal-to-background ratio and resolution with increasing imaging depth. This degradation is due to scattered emission photons being widely distributed, resulting in a strong background. To overcome this challenge, we have developed multiline orthogonal scanning temporal focusing (mosTF) microscopy. mosTF captures a sequence of images at each scan location of the excitation line. A reconstruction algorithm then reassigns scattered photons back to their correct scan positions. We demonstrate the effectiveness of mosTF by acquiring neuronal images of mice in vivo. Our results show remarkable improvements in in vivo brain imaging with mosTF, while maintaining its speed advantage.


Subject(s)
Brain , Animals , Brain/diagnostic imaging , Brain/metabolism , Mice , Algorithms , Microscopy, Fluorescence, Multiphoton/methods , Neurons/metabolism , Image Processing, Computer-Assisted/methods
3.
Anal Chem ; 96(21): 8467-8473, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38723271

ABSTRACT

Lipid droplets (LDs) store energy and supply fatty acids and cholesterol. LDs are a hallmark of chronic nonalcoholic fatty liver disease (NAFLD). Recently, studies have focused on the role of hepatic macrophages in NAFLD. Green fluorescent protein (GFP) is used for labeling the characteristic targets in bioimaging analysis. Cx3cr1-GFP mice are widely used in studying the liver macrophages such as the NAFLD model. Here, we have developed a tool for two-photon microscopic observation to study the interactions between LDs labeled with LD2 and liver capsule macrophages labeled with GFP in vivo. LD2, a small-molecule two-photon excitation fluorescent probe for LDs, exhibits deep-red (700 nm) fluorescence upon excitation at 880 nm, high cell staining ability and photostability, and low cytotoxicity. This probe can clearly observe LDs through two-photon microscopy (TPM) and enables the simultaneous imaging of GFP+ liver capsule macrophages (LCMs) in vivo in the liver capsule of Cx3cr1-GFP mice. In the NAFLD mouse model, Cx3cr1+ LCMs and LDs increased with the progress of fatty liver disease, and spatiotemporal changes in LCMs were observed through intravital 3D TPM images. LD2 will aid in studying the interactions and immunological roles of hepatic macrophages and LDs to better understand NAFLD.


Subject(s)
Lipid Droplets , Liver , Macrophages , Animals , Lipid Droplets/chemistry , Lipid Droplets/metabolism , Mice , Macrophages/metabolism , Liver/diagnostic imaging , Liver/metabolism , Liver/pathology , Green Fluorescent Proteins/metabolism , Green Fluorescent Proteins/chemistry , Non-alcoholic Fatty Liver Disease/diagnostic imaging , Non-alcoholic Fatty Liver Disease/pathology , Non-alcoholic Fatty Liver Disease/metabolism , Microscopy, Fluorescence, Multiphoton/methods , Fluorescent Dyes/chemistry , Mice, Inbred C57BL
4.
BMC Cancer ; 24(1): 652, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38811917

ABSTRACT

BACKGROUND: Pancreatic ductal adenocarcinoma (PDAC) ranks among the deadliest types of cancer, and it will be meaningful to search for new biomarkers with prognostic value to help clinicians tailor therapeutic strategies. METHODS: Here we tried to use an advanced optical imaging technique, multiphoton microscopy (MPM) combining second-harmonic generation (SHG) and two-photon excited fluorescence (TPEF) imaging, for the label-free detection of PDAC tissues from a cohort of 149 patients. An automated image processing method was used to extract collagen features from SHG images and the Kaplan-Meier survival analysis and Cox proportional hazards regression were used to assess the prognostic value of collagen signatures. RESULTS: SHG images clearly show the different characteristics of collagen fibers in tumor microenvironment. We gained eight collagen morphological features, and a Feature-score was derived for each patient by the combination of these features using ridge regression. Statistical analyses reveal that Feature-score is an independent factor, and can predict the overall survival of PDAC patients as well as provide well risk stratification. CONCLUSIONS: SHG imaging technique can potentially be a tool for the accurate diagnosis of PDAC, and this optical biomarker (Feature-score) may help clinicians make more approximate treatment decisions.


Subject(s)
Carcinoma, Pancreatic Ductal , Collagen , Pancreatic Neoplasms , Humans , Carcinoma, Pancreatic Ductal/diagnostic imaging , Carcinoma, Pancreatic Ductal/pathology , Carcinoma, Pancreatic Ductal/mortality , Carcinoma, Pancreatic Ductal/metabolism , Prognosis , Female , Male , Collagen/metabolism , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/pathology , Pancreatic Neoplasms/metabolism , Pancreatic Neoplasms/mortality , Pancreatic Neoplasms/diagnosis , Middle Aged , Aged , Second Harmonic Generation Microscopy/methods , Biomarkers, Tumor/metabolism , Biomarkers, Tumor/analysis , Kaplan-Meier Estimate , Microscopy, Fluorescence, Multiphoton/methods , Adult , Tumor Microenvironment
5.
Nano Lett ; 24(22): 6706-6713, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38775232

ABSTRACT

Three-photon fluorescence microscopy (3PFM) is a promising brain research tool with submicrometer spatial resolution and high imaging depth. However, only limited materials have been developed for 3PFM owing to the rigorous requirement of the three-photon fluorescence (3PF) process. Herein, under the guidance of a band gap engineering strategy, CdTe/CdSe/ZnS quantum dots (QDs) emitting in the near-infrared window are designed for constructing 3PF probes. The formation of type II structure significantly increased the three-photon absorption cross section of QDs and caused the delocalization of electron-hole wave functions. The time-resolved transient absorption spectroscopy confirmed that the decay of biexcitons was significantly suppressed due to the appropriate band gap alignment, which further enhanced the 3PF efficiency of QDs. By utilizing QD-based 3PF probes, high-resolution 3PFM imaging of cerebral vasculature was realized excited by a 1600 nm femtosecond laser, indicating the possibility of deep brain imaging with these 3PF probes.


Subject(s)
Brain , Quantum Dots , Quantum Dots/chemistry , Brain/diagnostic imaging , Photons , Animals , Microscopy, Fluorescence, Multiphoton/methods , Cadmium Compounds/chemistry , Sulfides/chemistry , Mice , Zinc Compounds/chemistry , Tellurium/chemistry , Selenium Compounds/chemistry , Humans
6.
J Vis Exp ; (206)2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38709031

ABSTRACT

Complications after lung transplantation are largely related to the host immune system responding to the graft. Such immune responses are regulated by crosstalk between donor and recipient cells. A better understanding of these processes relies on the use of preclinical animal models and is aided by an ability to study intra-graft immune cell trafficking in real-time. Intravital two-photon microscopy can be used to image tissues and organs for depths up to several hundred microns with minimal photodamage, which affords a great advantage over single-photon confocal microscopy. Selective use of transgenic mice with promoter-specific fluorescent protein expression and/or adoptive transfer of fluorescent dye-labeled cells during intravital two-photon microscopy allows for the dynamic study of single cells within their physiologic environment. Our group has developed a technique to stabilize mouse lungs, which has enabled us to image cellular dynamics in naïve lungs and orthotopically transplanted pulmonary grafts. This technique allows for detailed assessment of cellular behavior within the vasculature and in the interstitium, as well as for examination of interactions between various cell populations. This procedure can be readily learned and adapted to study immune mechanisms that regulate inflammatory and tolerogenic responses after lung transplantation. It can also be expanded to the study of other pathogenic pulmonary conditions.


Subject(s)
Intravital Microscopy , Lung Transplantation , Animals , Mice , Intravital Microscopy/methods , Lung Transplantation/methods , Lung/immunology , Lung/diagnostic imaging , Mice, Transgenic , Microscopy, Fluorescence, Multiphoton/methods
7.
Elife ; 132024 May 29.
Article in English | MEDLINE | ID: mdl-38808733

ABSTRACT

The flow of neural activity across the neocortex during active sensory discrimination is constrained by task-specific cognitive demands, movements, and internal states. During behavior, the brain appears to sample from a broad repertoire of activation motifs. Understanding how these patterns of local and global activity are selected in relation to both spontaneous and task-dependent behavior requires in-depth study of densely sampled activity at single neuron resolution across large regions of cortex. In a significant advance toward this goal, we developed procedures to record mesoscale 2-photon Ca2+ imaging data from two novel in vivo preparations that, between them, allow for simultaneous access to nearly all 0f the mouse dorsal and lateral neocortex. As a proof of principle, we aligned neural activity with both behavioral primitives and high-level motifs to reveal the existence of large populations of neurons that coordinated their activity across cortical areas with spontaneous changes in movement and/or arousal. The methods we detail here facilitate the identification and exploration of widespread, spatially heterogeneous neural ensembles whose activity is related to diverse aspects of behavior.


Subject(s)
Behavior, Animal , Neurons , Wakefulness , Animals , Mice , Wakefulness/physiology , Neurons/physiology , Behavior, Animal/physiology , Neocortex/physiology , Neocortex/diagnostic imaging , Male , Calcium/metabolism , Microscopy, Fluorescence, Multiphoton/methods
8.
Spectrochim Acta A Mol Biomol Spectrosc ; 316: 124342, 2024 Aug 05.
Article in English | MEDLINE | ID: mdl-38676981

ABSTRACT

Two spirobifluene-based fluorescent probes SPF1 and SPF2, were designed and synthesized. The probes displayed "turn-on" fluorescence response for Cysteine. One of the challenges in developing a Cysteine probe is to secure high selectivity. SPF1/SPF2 can discriminate Cysteine from GSH as well as Hcy, and showed high substrate selectivity. The detection limit of SPF1 is 36 nM, which is excellent comparing with other optical sensors for Cysteine. The sensing mechanism of SPF1/SPF2 was verified by experimental data and theoretical calculations. There was a good linear relationship between the fluorescence intensity of SPF1/SPF2 and the concentration of Cysteine. The MTT tests indicated that SPF1/SPF2 had low cytotoxicity and good biocompatibility. Theoretical calculations demonstrated that SPF1, SPF2, and their related reaction products with Cysteine exhibited good two-photon absorption properties. Finally, SPF1/SPF2 had been successfully applied to the imaging of Cysteine in living cells under two-photon excitation.


Subject(s)
Cysteine , Fluorescent Dyes , Spiro Compounds , Fluorescent Dyes/chemistry , Fluorescent Dyes/chemical synthesis , Cysteine/analysis , Humans , Spiro Compounds/chemistry , HeLa Cells , Optical Imaging/methods , Limit of Detection , Photons , Microscopy, Fluorescence, Multiphoton/methods , Spectrometry, Fluorescence/methods
9.
J Biomed Opt ; 29(3): 036501, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38487259

ABSTRACT

Significance: Label-free nonlinear optical microscopy has become a powerful tool for biomedical research. However, the possible photodamage risk hinders further clinical applications. Aim: To reduce these adverse effects, we constructed a new platform of simultaneous label-free autofluorescence multi-harmonic (SLAM) microscopy, featuring four-channel multimodal imaging, inline photodamage monitoring, and pulse repetition-rate tuning. Approach: Using a large-core birefringent photonic crystal fiber for spectral broadening and a prism compressor for pulse pre-chirping, this system allows users to independently adjust pulse width, repetition rate, and energy, which is useful for optimizing imaging conditions towards no/minimal photodamage. Results: It demonstrates label-free multichannel imaging at one excitation pulse per image pixel and thus paves the way for improving the imaging speed by a faster optical scanner with a low risk of nonlinear photodamage. Moreover, the system grants users the flexibility to autonomously fine-tune repetition rate, pulse width, and average power, free from interference, ensuring the discovery of optimal imaging conditions with high SNR and minimal phototoxicity across various applications. Conclusions: The combination of a stable laser source, independently tunable ultrashort pulse, photodamage monitoring features, and a compact design makes this new system a robust, powerful, and user-friendly imaging platform.


Subject(s)
Lasers , Photons , Nonlinear Optical Microscopy , Microscopy, Fluorescence, Multiphoton/methods
10.
Am J Physiol Heart Circ Physiol ; 326(5): H1291-H1303, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38517228

ABSTRACT

Increasing evidence indicates the role of mitochondrial and vascular dysfunction in aging and aging-associated pathologies; however, the exact mechanisms and chronological processes remain enigmatic. High-energy demand organs, such as the brain, depend on the health of their mitochondria and vasculature for the maintenance of normal functions, therefore representing vulnerable targets for aging. This methodology article describes an analysis pipeline for three-dimensional (3-D) mitochondria-associated signal geometry of two-photon image stacks of brain vasculature. The analysis methods allow the quantification of mitochondria-associated signals obtained in real time in their physiological environment. In addition, signal geometry results will allow the extrapolation of fission and fusion events under normal conditions, during aging, or in the presence of different pathological conditions, therefore contributing to our understanding of the role mitochondria play in a variety of aging-associated diseases with vascular etiology.NEW & NOTEWORTHY Analysis pipeline for 3-D mitochondria-associated signal geometry of two-photon image stacks of brain vasculature.


Subject(s)
Imaging, Three-Dimensional , Mitochondria , Mitochondria/metabolism , Animals , Microscopy, Fluorescence, Multiphoton/methods , Endothelial Cells/metabolism , Mitochondrial Dynamics , Brain/blood supply , Brain/metabolism , Mice , Aging/metabolism
11.
Chemistry ; 30(31): e202400009, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38446718

ABSTRACT

An effective, GFP-inspired fluorescent Zn2+ sensor is developed for two-photon microscopy and related biological application that features an 8-methoxyquinoline moiety. Excellent photophysical characteristics including a 37-fold fluorescence enhancement with excitation and emission maxima at 440 nm and 505 nm, respectively, as well as a high two-photon cross-section of 73 GM at 880 nm are reported. Based on the experimental data, the relationship between the structure and properties was elucidated and explained backed up by DFT calculations, particularly the observed PeT phenomenon for the turn-on process. Biological validation and detailed experimental and theoretical characterization of the free and the zinc-bound compounds are presented.


Subject(s)
Fluorescent Dyes , Green Fluorescent Proteins , Quinolines , Zinc , Zinc/chemistry , Fluorescent Dyes/chemistry , Quinolines/chemistry , Green Fluorescent Proteins/chemistry , Humans , Density Functional Theory , Microscopy, Fluorescence, Multiphoton/methods , Photons
12.
Commun Biol ; 7(1): 364, 2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38531976

ABSTRACT

For generations researchers have been observing the dynamic processes of life through the lens of a microscope. This has offered tremendous insights into biological phenomena that span multiple orders of time- and length-scales ranging from the pure magic of molecular reorganization at the membrane of immune cells, to cell migration and differentiation during development or wound healing. Standard fluorescence microscopy techniques offer glimpses at such processes in vitro, however, when applied in intact systems, they are challenged by reduced signal strengths and signal-to-noise ratios that result from deeper imaging. As a remedy, two-photon excitation (TPE) microscopy takes a special place, because it allows us to investigate processes in vivo, in their natural environment, even in a living animal. Here, we review the fundamental principles underlying TPE aimed at basic and advanced microscopy users interested in adopting TPE for intravital imaging. We focus on applications in neurobiology, present current trends towards faster, wider and deeper imaging, discuss the combination with photon counting technologies for metabolic imaging and spectroscopy, as well as highlight outstanding issues and drawbacks in development and application of these methodologies.


Subject(s)
Intravital Microscopy , Microscopy, Fluorescence, Multiphoton , Animals , Microscopy, Fluorescence, Multiphoton/methods , Microscopy, Fluorescence/methods , Spectrum Analysis , Photons
13.
Microsc Microanal ; 30(2): 342-358, 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38525887

ABSTRACT

Deviation of blood flow from an optimal range is known to be associated with the initiation and progression of vascular pathologies. Important open questions remain about how the abnormal flow drives specific wall changes in pathologies such as cerebral aneurysms where the flow is highly heterogeneous and complex. This knowledge gap precludes the clinical use of readily available flow data to predict outcomes and improve treatment of these diseases. As both flow and the pathological wall changes are spatially heterogeneous, a crucial requirement for progress in this area is a methodology for acquiring and comapping local vascular wall biology data with local hemodynamic data. Here, we developed an imaging pipeline to address this pressing need. A protocol that employs scanning multiphoton microscopy was developed to obtain three-dimensional (3D) datasets for smooth muscle actin, collagen, and elastin in intact vascular specimens. A cluster analysis was introduced to objectively categorize the smooth muscle cells (SMC) across the vascular specimen based on SMC actin density. Finally, direct quantitative comparison of local flow and wall biology in 3D intact specimens was achieved by comapping both heterogeneous SMC data and wall thickness to patient-specific hemodynamic results.


Subject(s)
Extracellular Matrix , Hemodynamics , Microscopy, Fluorescence, Multiphoton , Microscopy, Fluorescence, Multiphoton/methods , Myocytes, Smooth Muscle/physiology , Myocytes, Smooth Muscle/cytology , Actins/metabolism , Animals , Collagen/metabolism , Humans , Elastin/metabolism , Elastin/analysis , Imaging, Three-Dimensional/methods , Arteries
14.
Anal Chem ; 96(8): 3535-3543, 2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38353024

ABSTRACT

Currently, in situ monitoring of the adenosine triphosphate (ATP) level in lysosomes is critical to understand their involvement in various biological processes, but it remains difficult due to the interferences of limited targeting and low resolution of fluorescent probes. Herein, we report a classic Mn(II) probe (FX2-MnCl2) with near-infrared (NIR) nonlinear (NLO) properties, accompanied by three-four photon transition and fivefold fluorescence enhancement in the presence of ATP. FX2-MnCl2 combines with ATP through dual recognition sites of diethoxy and manganese ions to reflect slightly fluorescence lifetime change. Through the synergy of multiphoton fluorescence imaging (MP-FI) and multiphoton fluorescence lifetime imaging microscopy (MP-FLIM), it is further demonstrated that FX2-MnCl2 displays lysosome-specific targeting behavior, which can monitor lysosome-related ATP migration under NIR laser light. This work provides a novel multiphoton transformation fluorescence complex, which might be a potential candidate as a simple and straightforward biomarker of lysosome ATP in vitro for clinical diagnosis.


Subject(s)
Fluorescent Dyes , Lysosomes , Microscopy, Fluorescence/methods , Optical Imaging , Photons , Microscopy, Fluorescence, Multiphoton/methods
15.
Int J Mol Sci ; 25(3)2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38338948

ABSTRACT

Two-photon excitation microscopy (TPM) and multiphoton fluorescence microscopy (MPM) are advanced forms of intravital high-resolution functional microscopy techniques that allow for the imaging of dynamic molecular processes and resolve features of the biological tissues of interest. Due to the cornea's optical properties and the uniquely accessible position of the globe, it is possible to image cells and tissues longitudinally to investigate ocular surface physiology and disease. MPM can also be used for the in vitro investigation of biological processes and drug kinetics in ocular tissues. In corneal immunology, performed via the use of TPM, cells thought to be intraepithelial dendritic cells are found to resemble tissue-resident memory T cells, and reporter mice with labeled plasmacytoid dendritic cells are imaged to understand the protective antiviral defenses of the eye. In mice with limbal progenitor cells labeled by reporters, the kinetics and localization of corneal epithelial replenishment are evaluated to advance stem cell biology. In studies of the conjunctiva and sclera, the use of such imaging together with second harmonic generation allows for the delineation of matrix wound healing, especially following glaucoma surgery. In conclusion, these imaging models play a pivotal role in the progress of ocular surface science and translational research.


Subject(s)
Cornea , Sclera , Animals , Mice , Microscopy, Fluorescence , Microscopy, Fluorescence, Multiphoton/methods , Conjunctiva
16.
J Biophotonics ; 17(4): e202300422, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38211977

ABSTRACT

Multiphoton microscopy (MPM) enables deep brain imaging. Three optical windows: NIR-I, NIR-II, and NIR-III are widely used. Recently, NIR-IV (the 2200 nm window) has been demonstrated to be the last and longest window for deep tissue MPM. However, so far MPM covers only two optical windows labeled by single fluorescent probe, one for emission and one for excitation. Here we demonstrate in vivo deep brain MPM covering three optical windows, with emission at NIR-I, NIR-II, and excitation at NIR-IV, labeled by ICG. The innovations include: (1) characterizing both 3-photon excitation and emission properties of ICG emitting at both NIR-I and NIR-II, in water, plasma, and circulating blood; (2) a home-built multiphoton microscope with simultaneous dual channel detection, with which we demonstrate deep brain MPM 950 µm (NIR-I) and 850 µm (NIR-II) into the mouse brain in vivo, verifying that multi-optical window MPM is promising for deep brain imaging.


Subject(s)
Brain , Microscopy, Fluorescence, Multiphoton , Mice , Animals , Microscopy, Fluorescence, Multiphoton/methods , Brain/diagnostic imaging , Fluorescent Dyes , Optical Imaging/methods , Spectroscopy, Near-Infrared/methods
17.
J Biophotonics ; 17(4): e202300417, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38221649

ABSTRACT

Pancreatic intraepithelial neoplasia (PanIN) is the most common precursor lesion that has the potential to progress to invasive pancreatic cancer, and early and rapid detection may offer patients a chance for treatment before the development of invasive carcinoma. Therefore, the identification of PanIN holds significant clinical importance. In this study, we first used multiphoton microscopy (MPM) combining two-photon excitation fluorescence and second-harmonic generation imaging to label-free detect PanIN and attempted to differentiate between normal pancreatic ducts and different grades of PanIN. Then, we also developed an automatic image processing strategy to extract eight morphological features of collagen fibers from MPM images to quantify the changes in collagen fibers surrounding the ducts. Experimental results demonstrate that the combination of MPM and quantitative information can accurately identify normal pancreatic ducts and different grades of PanIN. This study may contribute to the rapid diagnosis of pancreatic diseases and may lay the foundation for further clinical application of MPM.


Subject(s)
Microscopy , Pancreatic Neoplasms , Humans , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/pathology , Pancreas , Collagen , Microscopy, Fluorescence, Multiphoton/methods
18.
Lab Invest ; 104(4): 100324, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38220044

ABSTRACT

Meningiomas rank among the most common intracranial tumors, and surgery stands as the primary treatment modality for meningiomas. The precise subtyping and diagnosis of meningiomas, both before and during surgery, play a pivotal role in enabling neurosurgeons choose the optimal surgical program. In this study, we utilized multiphoton microscopy (MPM) based on 2-photon excited fluorescence and second-harmonic generation to identify 5 common meningioma subtypes. The morphological features of these subtypes were depicted using the MPM multichannel mode. Additionally, we developed 2 distinct programs to quantify collagen content and blood vessel density. Furthermore, the lambda mode of the MPM characterized architectural and spectral features, from which 3 quantitative indicators were extracted. Moreover, we employed machine learning to differentiate meningioma subtypes automatically, achieving high classification accuracy. These findings demonstrate the potential of MPM as a noninvasive diagnostic tool for meningioma subtyping and diagnosis, offering improved accuracy and resolution compared with traditional methods.


Subject(s)
Meningeal Neoplasms , Meningioma , Humans , Meningioma/diagnostic imaging , Collagen , Microscopy, Fluorescence, Multiphoton/methods , Meningeal Neoplasms/diagnostic imaging , Computers
19.
Methods Mol Biol ; 2773: 125-135, 2024.
Article in English | MEDLINE | ID: mdl-38236542

ABSTRACT

Intravital microscopy allows a direct visualization of cells' behavior in their environment in a living organism with all its complexity. With appropriated models, longitudinal studies of structural and functional changes can be followed in the same animal on long period. In the field of cancer, the dorsal window chamber model is the model of choice for tumor events such as cells migration, vessels growth, and their permeability or interactions between cells and vessels. Coupled with wide-field, confocal, or multiphoton fluorescence microscopes, high spatial and temporal resolutions of the cellular events can be analyzed in vivo.


Subject(s)
Intravital Microscopy , Microscopy, Fluorescence, Multiphoton , Animals , Cell Movement , Permeability
20.
Sensors (Basel) ; 24(2)2024 Jan 20.
Article in English | MEDLINE | ID: mdl-38276359

ABSTRACT

The intrinsic fluorescence of bacterial samples has a proven potential for label-free bacterial characterization, monitoring bacterial metabolic functions, and as a mechanism for tracking the transport of relevant components through vesicles. The reduced scattering and axial confinement of the excitation offered by multiphoton imaging can be used to overcome some of the limitations of single-photon excitation (e.g., scattering and out-of-plane photobleaching) to the imaging of bacterial communities. In this work, we demonstrate in vivo multi-photon microscopy imaging of Streptomyces bacterial communities, based on the excitation of blue endogenous fluorophores, using an ultrafast Yb-fiber laser amplifier. Its parameters, such as the pulse energy, duration, wavelength, and repetition rate, enable in vivo multicolor imaging with a single source through the simultaneous two- and three-photon excitation of different fluorophores. Three-photon excitation at 1040 nm allows fluorophores with blue and green emission spectra to be addressed (and their corresponding ultraviolet and blue single-photon excitation wavelengths, respectively), and two-photon excitation at the same wavelength allows fluorophores with yellow, orange, or red emission spectra to be addressed (and their corresponding green, yellow, and orange single-photon excitation wavelengths). We demonstrate that three-photon excitation allows imaging over a depth range of more than 6 effective attenuation lengths to take place, corresponding to an 800 micrometer depth of imaging, in samples with a high density of fluorescent structures.


Subject(s)
Fluorescent Dyes , Photons , Fluorescent Dyes/chemistry , Microscopy, Confocal/methods , Lasers , Light , Microscopy, Fluorescence, Multiphoton/methods
SELECTION OF CITATIONS