Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 8.753
Filter
1.
J Cardiovasc Med (Hagerstown) ; 25(7): 529-538, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38829939

ABSTRACT

AIMS: This study assessed the outcomes of concomitant mitral valve disease and severe aortic stenosis in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS: Echocardiographic data of 813 patients with severe aortic stenosis undergoing transfemoral TAVR were collected, and clinical outcomes were analyzed for individuals with mitral stenosis and mitral regurgitation. RESULTS: The final cohort includes 788 patients with severe calcific aortic stenosis. Among single parameters of mitral stenosis, a smaller baseline mitral valve area (MVA) by the continuity equation and higher postprocedural mean mitral gradients (MMG) were associated with an increased risk of death at 1 year (P-values 0.02 and <0.01, respectively), but no correlation with outcomes was demonstrated after multivariate adjustment for major prognosticators. Mitral stenosis (based on MVA + MMG) was not associated with complications or mortality. Mitral regurgitation was present in 94.6% of the population at baseline and regressed by at least one grade post-TAVR in 28% of the patients. The improvement in mitral regurgitation was associated with a greater prosthetic effective orifice area (P-value 0.03). Significant (at least moderate) residual mitral regurgitation was correlated with short-term complications and shown to be an independent predictor of 1-year mortality (P-value 0.02, odds ratio (OR) 5.37, confidence interval 1.34-21.5). CONCLUSION: Mitral regurgitation has a greater impact on TAVR patients than mitral stenosis as assessed by functional methods.


Subject(s)
Aortic Valve Stenosis , Mitral Valve Insufficiency , Mitral Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Mitral Valve Stenosis/surgery , Mitral Valve Stenosis/diagnostic imaging , Mitral Valve Stenosis/mortality , Mitral Valve Stenosis/physiopathology , Mitral Valve Stenosis/complications , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/complications , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/complications , Aged , Treatment Outcome , Severity of Illness Index , Retrospective Studies , Prognosis , Risk Factors , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Calcinosis/mortality , Calcinosis/diagnostic imaging , Calcinosis/complications , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/physiopathology , Echocardiography
2.
Ann Card Anaesth ; 27(1): 68-69, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722126

ABSTRACT

ABSTRACT: The occurrence of pulmonary artery thrombus in association with rheumatic mitral stenosis is a rare complication. Pulmonary artery thrombus formation may worsen pulmonary artery pressures, and this may precipitate acute right heart failure. The possible mechanisms behind pulmonary artery thrombus formation during mitral valve replacement surgery could be acute coagulopathy following surgery, the presence of chronic pulmonary thromboembolism, or chronic atrial fibrillation. We report an unusual case of pulmonary artery thrombus in a patient with rheumatic MS which was diagnosed with transoesophageal echocardiography after MVR.


Subject(s)
Delayed Diagnosis , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation , Mitral Valve , Pulmonary Artery , Thrombosis , Humans , Heart Valve Prosthesis Implantation/adverse effects , Pulmonary Artery/diagnostic imaging , Echocardiography, Transesophageal/methods , Thrombosis/diagnostic imaging , Thrombosis/etiology , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve Stenosis/surgery , Female , Rheumatic Heart Disease/complications , Rheumatic Heart Disease/surgery , Pulmonary Embolism/etiology , Pulmonary Embolism/diagnostic imaging , Middle Aged
3.
Ann Card Anaesth ; 27(1): 70-75, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722127

ABSTRACT

ABSTRACT: A sub-mitral left ventricular aneurysm is a rare condition. It is a congenital outpouching of the left ventricular wall, invariably occurring adjacent to the posterior mitral leaflet. Sub-mitral aneurysm (SMA) has usually been reported as a consequence of myocardial ischemia (MI), rheumatic heart disease, tuberculosis, and infective endocarditis. Nevertheless, there have been few case reports of congenital SMA in India. It usually presents with symptoms of heart failure. We report a rare case of congenital SMA in a 27-year-old young Indian and its successful management through a trans-aneurysmal approach.


Subject(s)
Heart Aneurysm , Mitral Valve , Humans , Adult , Heart Aneurysm/surgery , Heart Aneurysm/diagnostic imaging , Heart Aneurysm/congenital , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Male , Heart Ventricles/surgery , Heart Ventricles/diagnostic imaging , Echocardiography, Transesophageal/methods , Anesthetics
5.
Braz J Cardiovasc Surg ; 39(4): e20230237, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748975

ABSTRACT

Transcatheter mitral valve-in-valve is an alternative to high-risk reoperation on a failing bioprosthesis. It entails specific challenges such as left ventricular outflow tract obstruction. We propose a patient-specific augmented imaging based on preoperative planning to assist the procedure. Valve-in-valve simulation was performed to represent the optimal level of implantation and the neo-left ventricular outflow tract. These data were combined with intraoperative images through a real-time 3D/2D registration tool. All data were collected retrospectively on one case (pre and per-procedure imaging). We present for the first time an intraoperative guidance tool in transcatheter mitral valve-in-valve procedure.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve , Surgery, Computer-Assisted , Humans , Heart Valve Prosthesis Implantation/methods , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Surgery, Computer-Assisted/methods , Cardiac Catheterization/methods , Bioprosthesis , Retrospective Studies , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Female , Male
6.
Sci Rep ; 14(1): 11745, 2024 05 23.
Article in English | MEDLINE | ID: mdl-38778204

ABSTRACT

Preclinical in vivo evaluation is an essential step in the progression of new cardiac devices into patient use, with studies predominantly performed in the domestic sheep model. A growing area of interest in cardiac device development is transcatheter mitral valve replacement (TMVR). Clinically, multimodal imaging, or computed tomography (CT) and echocardiography (echo) are used extensively to preoperatively determine mitral valve morphology prior to an intervention, but there is no description on how these modalities can be implemented to support preclinical studies. The purpose of this study is to apply clinically relevant CT and echo acquisition and assessment techniques to a large group of naive research sheep in order to analyze and report modality-related effects on mitral valve dimensional reference intervals in the sheep model. To this end, fifty-five adult domestic sheep underwent preoperative CT and echo exams and resultant images were analyzed using a landmark-based multiplanar measurement protocol and compiled into a master dataset for statistical analysis. We found moderate agreement between CT and echo-derived measurements of the mitral valve in sheep and propose the first clinically-relevant dimensional indices for the sheep's naive mitral valve which can be used to guide future studies evaluating novel TMVR devices. This study is the first of its kind in proposing a reproducible method for detailed examination of the mitral valve in the sheep model using clinically-relevant multimodal imaging. As in patients, CT and echo can reveal accurate native mitral valve dimensions in the sheep prior to preclinical TMVR studies.


Subject(s)
Echocardiography , Heart Valve Prosthesis Implantation , Mitral Valve , Multimodal Imaging , Tomography, X-Ray Computed , Animals , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Sheep , Heart Valve Prosthesis Implantation/methods , Echocardiography/methods , Tomography, X-Ray Computed/methods , Multimodal Imaging/methods , Sheep, Domestic , Cardiac Catheterization/methods
7.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38742523

ABSTRACT

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Registries , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Male , Female , Aged , Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Italy/epidemiology , Aged, 80 and over , Patient Readmission/statistics & numerical data , Treatment Failure , Heart Valve Prosthesis , Mitral Valve Annuloplasty/instrumentation , Mitral Valve Annuloplasty/adverse effects , Treatment Outcome , Time Factors , Risk Factors , Heart Failure/mortality , Heart Failure/physiopathology , Heart Failure/surgery
9.
Int J Cardiol ; 408: 132112, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38697399

ABSTRACT

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is an alternative to conventional surgery to treat severe mitral disease but its use is limited by the risk of left ventricular outflow tract obstruction (LVOTO). Screening depends on ECG-gated computed tomography (CT) that is not widely available and requires contrast. We developed and validated a transthoracic echocardiographic (TTE) method to assess the risk of LVOTO after TMVR with the Tendyne System. METHODS: We measured the LVOT longitudinal area on preoperative TTE dataset of patients screened for TMVR. The LVOT was measured as the box-area included by the aortic valve annulus, the anterior mitral leaflet (AML), the c-septum distance line, and the respective length of the AML on the interventricular septum. We analyzed the correlation between the TTE LVOT-box and the CT-measured neoLVOT area. Prediction performance for eligible patients was tested with ROC curves. RESULTS: Thirty-nine patients were screened, out of 14 patients (36%) not eligible for TMVR, 8 had risk of LVOTO. We found a linear correlation between the TTE LVOT-box and the CT-measured Neo-LVOT (r = 0.6, p = 0.002). ROC curve showed that the method is specific and sensitive and the cut-off value of the measure LVOT-box is 350 mm2. CONCLUSIONS: The proposed method is reliable to evaluate the risk of LVOTO after TMR with the Tendyne System. It is quick and easy and can be used as a first-line assessment in the outpatient clinic. Patients with LVOT-box <350 mm2 should not be further screened with ECG-gated cardiac CT.


Subject(s)
Echocardiography , Ventricular Outflow Obstruction , Humans , Female , Male , Echocardiography/methods , Aged , Risk Assessment/methods , Ventricular Outflow Obstruction/diagnostic imaging , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Middle Aged , Retrospective Studies , Cardiac Catheterization/methods , Aged, 80 and over , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery
11.
J Cardiothorac Surg ; 19(1): 281, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38715080

ABSTRACT

Injury to coronary arteries during mitral surgery is a rare but life-threatening procedural complication, an anomalous origin and course of the left circumflex artery (LCx) increase this risk. Recognizing the anomaly by the characteristic angiographic pattern and identifying its relationship with the surrounding anatomical structure using imaging techniques, mainly transesophageal echocardiography (TOE) or coronary computed tomography angiography (CCTA), is of crucial importance in setting up the best surgical strategy. We report a case of anomalous origin of a circumflex artery (LCx) from the proximal portion of the right coronary artery (RCA) with a pathway running retroaortically through the mitro-aortic space. An integrated diagnostic approach using a multidisciplinary team with a cardiologist and an imaging radiologist allowed us to decide the surgical strategy. We successfully performed a mitral valvular repair using a minimally invasive minithoracotomic approach and implanting a complete semirigid ring.


Subject(s)
Aortic Valve , Coronary Vessel Anomalies , Echocardiography, Transesophageal , Mitral Valve , Humans , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/abnormalities , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/abnormalities , Coronary Vessel Anomalies/surgery , Coronary Vessel Anomalies/diagnostic imaging , Coronary Angiography , Computed Tomography Angiography , Male , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Female , Coronary Vessels/surgery , Coronary Vessels/diagnostic imaging
12.
Clin Cardiol ; 47(5): e24272, 2024 May.
Article in English | MEDLINE | ID: mdl-38742736

ABSTRACT

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve , Prosthesis Failure , Humans , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Echocardiography, Transesophageal , Male , Treatment Outcome , Female , Aged , Reoperation
13.
Catheter Cardiovasc Interv ; 103(7): 1138-1144, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38695165

ABSTRACT

Following the introduction in the latest European and American guidelines, transcatheter edge-to-edge repair has become a valid alternative to surgery for ineligible patients. Among the available technologies, MitraClip (Abbott) was the first to be introduced for the percutaneous treatment of mitral regurgitation with the edge-to-edge technique. Although its safety and effectiveness has been widely demonstrated, the optimal procedural results are highly dependent from operators' experience. In this manuscript, we provide a full guide of advanced steering maneuvers of MitraClip in different scenarios of transseptal puncture.


Subject(s)
Cardiac Catheterization , Cardiac Catheters , Mitral Valve Insufficiency , Mitral Valve , Punctures , Humans , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Treatment Outcome , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Equipment Design , Heart Septum/surgery , Heart Septum/diagnostic imaging , Heart Valve Prosthesis
14.
J Am Heart Assoc ; 13(11): e032706, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38804217

ABSTRACT

BACKGROUND: Currently, no clear impact of sex on short- and long-term survival following transcatheter edge-to-edge mitral valve repair (TEER) is evident, although no data are available on postprocedural life expectancy. Our aim was to assess sex-specific differences in outcomes of patients with mitral regurgitation (MR) treated by TEER. METHODS AND RESULTS: Short-term and 5-year outcomes in men and women undergoing TEER between 2011 and 2018 who were included in the large, multicenter, real-world MitraSwiss registry were analyzed. Outcomes were compared stratified by sex and according to MR cause (primary versus secondary). The impact of TEER on postprocedural life expectancy was estimated by relative survival analysis. Among 1142 patients aged 60 to 89 years, 39.8% were women. They were older, with fewer cardiovascular risk factors and lower functional capacity compared with men. Thirty-day mortality was higher in men than in women (3.3% versus 1.1%; odds ratio, 3.16 [95% CI, 1.16-10.7]; P=0.020). Five-year survival was comparable in both sexes (adjusted hazard ratio for 5-year mortality in men, 1.14 [95% CI, 0.90-1.44], P=0.275). Both men and women with either primary or secondary MR showed similar clinical efficacy over time. TEER provided high relative survival estimates among all groups, and fully restored predicted life expectancy in women with primary MR (5-year relative survival estimate, 97.4% [95% CI, 85.5-107.0]). CONCLUSIONS: TEER is not associated with increased short-term mortality in women, whereas 5-year outcomes are comparable between sexes. Moreover, TEER completely restored normal life expectancy in women with primary MR. A residual excess mortality persists in secondary MR, independently of sex.


Subject(s)
Cardiac Catheterization , Mitral Valve Insufficiency , Registries , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Female , Aged , Male , Aged, 80 and over , Middle Aged , Sex Factors , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Risk Factors , Life Expectancy , Time Factors
15.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599690

ABSTRACT

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Cardiac Catheterization/methods
18.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599692

ABSTRACT

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Follow-Up Studies , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Quality of Life , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects
20.
Circ Cardiovasc Interv ; 17(4): e013196, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38626077

ABSTRACT

BACKGROUND: Various mitral repair techniques have been described. Though these repair techniques can be highly effective when performed correctly in suitable patients, limited quantitative biomechanical data are available. Validation and thorough biomechanical evaluation of these repair techniques from translational large animal in vivo studies in a standardized, translatable fashion are lacking. We sought to evaluate and validate biomechanical differences among different mitral repair techniques and further optimize repair operations using a large animal mitral valve prolapse model. METHODS: Male Dorset sheep (n=20) had P2 chordae severed to create the mitral valve prolapse model. Fiber Bragg grating force sensors were implanted to measure chordal forces. Ten sheep underwent 3 randomized, paired mitral valve repair operations: neochord repair, nonresectional leaflet remodeling, and triangular resection. The other 10 sheep underwent neochord repair with 2, 4, and 6 neochordae. Data were collected at baseline, mitral valve prolapse, and after each repair. RESULTS: All mitral repair techniques successfully eliminated regurgitation. Compared with mitral valve prolapse (0.54±0.18 N), repair using neochord (0.37±0.20 N; P=0.02) and remodeling techniques (0.30±0.15 N; P=0.001) reduced secondary chordae peak force. Neochord repair further decreased primary chordae peak force (0.21±0.14 N) to baseline levels (0.20±0.17 N; P=0.83), and was associated with lower primary chordae peak force compared with the remodeling (0.34±0.18 N; P=0.02) and triangular resectional techniques (0.36±0.27 N; P=0.03). Specifically, repair using 2 neochordae resulted in higher peak primary chordal forces (0.28±0.21 N) compared with those using 4 (0.22±0.16 N; P=0.02) or 6 neochordae (0.19±0.16 N; P=0.002). No difference in peak primary chordal forces was observed between 4 and 6 neochordae (P=0.05). Peak forces on the neochordae were the lowest using 6 neochordae (0.09±0.11 N) compared with those of 4 neochordae (0.15±0.14 N; P=0.01) and 2 neochordae (0.29±0.18 N; P=0.001). CONCLUSIONS: Significant biomechanical differences were observed underlying different mitral repair techniques in a translational large animal model. Neochord repair was associated with the lowest primary chordae peak force compared to the remodeling and triangular resectional techniques. Additionally, neochord repair using at least 4 neochordae was associated with lower chordal forces on the primary chordae and the neochordae. This study provided key insights about mitral valve repair optimization and may further improve repair durability.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve Prolapse , Humans , Male , Animals , Sheep , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Chordae Tendineae/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...