Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 8.847
Filter
1.
Circ Cardiovasc Imaging ; 17(5): e016267, 2024 May.
Article in English | MEDLINE | ID: mdl-38771899

ABSTRACT

BACKGROUND: Aortic valve calcification (AVC) indexation to the aortic annulus (AA) area measured by Doppler echocardiography (AVCdEcho) provides powerful prognostic information in patients with aortic stenosis (AS). However, the indexation by AA measured by multidetector computed tomography (AVCdCT) has never been evaluated. The aim of this study was to compare AVC, AVCdCT, and AVCdEcho with regard to hemodynamic correlations and clinical outcomes in patients with AS. METHODS: Data from 889 patients, mainly White, with calcific AS who underwent Doppler echocardiography and multidetector computed tomography within the same episode of care were retrospectively analyzed. AA was measured both by Doppler echocardiography and multidetector computed tomography. AVCdCT severity thresholds were established using receiver operating characteristic curve analyses in men and women separately. The primary end point was the occurrence of all-cause mortality. RESULTS: Correlations between gradient/velocity and AVCd were stronger (both P≤0.005) using AVCdCT (r=0.68, P<0.001 and r=0.66, P<0.001) than AVC (r=0.61, P<0.001 and r=0.60, P<0.001) or AVCdEcho (r=0.61, P<0.001 and r=0.59, P<0.001). AVCdCT thresholds for the identification of severe AS were 334 Agatston units (AU)/cm2 for women and 467 AU/cm2 for men. On a median follow-up of 6.62 (6.19-9.69) years, AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict all-cause mortality in multivariate analyses (hazard ratio [HR], 1.59 [95% CI, 1.26-2.00]; P<0.001 versus HR, 1.53 [95% CI, 1.11-1.65]; P=0.003 versus HR, 1.27 [95% CI, 1.11-1.46]; P<0.001; all likelihood test P≤0.004). AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict survival under medical treatment in multivariate analyses (HR, 1.80 [95% CI, 1.27-1.58]; P<0.001 compared with HR, 1.55 [95% CI, 1.13-2.10]; P=0.007; HR, 1.28 [95% CI, 1.03-1.57]; P=0.01; all likelihood test P<0.03). AVCdCT ratio predicts mortality in all subgroups of patients with AS. CONCLUSIONS: AVCdCT appears to be equivalent or superior to AVC and AVCdEcho to assess AS severity and predict all-cause mortality. Thus, it should be used to evaluate AS severity in patients with nonconclusive echocardiographic evaluations with or without low-flow status. AVCdCT thresholds of 300 AU/cm2 for women and 500 AU/cm2 for men seem to be appropriate to identify severe AS. Further studies are needed to validate these thresholds, especially in diverse populations.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Calcinosis , Echocardiography, Doppler , Multidetector Computed Tomography , Predictive Value of Tests , Severity of Illness Index , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Male , Female , Multidetector Computed Tomography/methods , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Retrospective Studies , Aged , Calcinosis/diagnostic imaging , Calcinosis/physiopathology , Calcinosis/mortality , Echocardiography, Doppler/methods , Aged, 80 and over , Prognosis , ROC Curve , Hemodynamics , Middle Aged , Risk Factors
2.
Tomography ; 10(5): 727-737, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38787016

ABSTRACT

PURPOSE: The purpose of this study was to analyze the prevalence of and complications resulting from temporal bone fractures in adult and pediatric patients evaluated for cranio-facial trauma in an emergency setting. METHODS: A retrospective blinded analysis of CT scans of a series of 294 consecutive adult and pediatric patients with cranio-facial trauma investigated in the emergency setting was conducted. Findings were compared between the two populations. Preliminary reports made by on-call residents were compared with the retrospective analysis, which was performed in consensus by two experienced readers and served as reference standard. RESULTS: CT revealed 126 fractures in 116/294 (39.5%) patients, although fractures were clinically suspected only in 70/294 (23.8%); p < 0.05. Fractures were longitudinal, transverse and mixed in 69.5%, 10.3% and 19.8% of cases, respectively. Most fractures were otic-sparing fractures (95.2%). Involvement of the external auditory canal, ossicular chain and the osseous structures surrounding the facial nerve was present in 72.2%, 8.7% and 6.3% of cases, respectively. Temporal bone fractures extended into the venous sinuses/jugular foramen and carotid canal in 18.3% and 17.5% of cases, respectively. Vascular injuries (carotid dissection and venous thrombosis) were more common in children than in adults (13.6% versus 5.3%); however, the observed difference did not reach statistical significance. 79.5% of patients with temporal bone fractures had both brain injuries and fractures of the facial bones and cranial vault. Brain injuries were more common in adults (90.4%) than in children (63.6%), p = 0.001. Although on-call residents reliably detected temporal bone fractures (sensitivity = 92.8%), they often missed trauma-associated ossicular dislocation (sensitivity = 27.3%). CONCLUSIONS: Temporal bone fractures and related complications are common in patients with cranio-facial trauma and need to be thoroughly looked for; the pattern of associated injuries is slightly different in children and in adults.


Subject(s)
Skull Fractures , Temporal Bone , Humans , Temporal Bone/diagnostic imaging , Temporal Bone/injuries , Male , Female , Adult , Child , Retrospective Studies , Skull Fractures/diagnostic imaging , Skull Fractures/complications , Adolescent , Middle Aged , Child, Preschool , Aged , Young Adult , Aged, 80 and over , Infant , Multidetector Computed Tomography/methods , Facial Injuries/diagnostic imaging , Prevalence , Emergency Service, Hospital , Craniocerebral Trauma/diagnostic imaging , Craniocerebral Trauma/complications , Tomography, X-Ray Computed/methods
3.
Clin Chest Med ; 45(2): 237-248, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38816085

ABSTRACT

The pericardium comprises a double-walled fibrous-serosal sac that encloses the heart. Reflections of the serosal layer form sinuses and recesses. With advances in multidetector computed tomography (CT) technology, pericardial recesses are frequently detected with thin-section CT. Knowledge of pericardial anatomy on imaging is crucial to avoid misinterpretation of fluid-filled pericardial sinuses and recesses as adenopathy/pericardial metastasis or aortic dissection, which can impact patient management and treatment decisions. The authors offer a comprehensive review of pericardial anatomy and its variations observed on CT, potential pitfalls in image interpretation, and implications for the pulmonologist with respect to unnecessary diagnostic procedures or interventions.


Subject(s)
Pericardium , Humans , Pericardium/diagnostic imaging , Tomography, X-Ray Computed , Pulmonologists , Multidetector Computed Tomography/methods
4.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38691562

ABSTRACT

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Septum , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Ventricular Septum/diagnostic imaging , Aged, 80 and over , Risk Factors , Aged , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnostic imaging , Heart Conduction System/physiopathology , Heart Conduction System/diagnostic imaging , Treatment Outcome , Predictive Value of Tests , Risk Assessment , Severity of Illness Index , Retrospective Studies , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Multidetector Computed Tomography , Tomography, X-Ray Computed , Action Potentials
5.
J Am Heart Assoc ; 13(10): e034776, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38726920

ABSTRACT

BACKGROUND: The determinants and prognostic value of high-sensitivity cardiac troponin T (hs-cTnT) among patients with a systemic right ventricle are largely unknown. METHODS AND RESULTS: Ninety-eight patients from the randomized controlled SERVE (Effect of Phosphodiesterase-5 Inhibition With Tadalafil on Systemic Right Ventricular Size and Function) trial were included. The correlation between baseline hs-cTnT concentrations and biventricular volumes and function quantified by cardiac magnetic resonance or cardiac multirow detector computed tomography was assessed by adjusted linear regression models. The prognostic value of hs-cTnT was assessed by adjusted Cox proportional hazards models, survival analysis, and concordance statistics. The primary outcome was time to the composite of clinically relevant arrhythmia, hospitalization for heart failure, or all-cause death. Median age was 39 (interquartile range, 32-48) years, and 32% were women. Median hs-cTnT concentration was 7 (interquartile range, 4-11) ng/L. Coefficients of determination for the relationship between hs-cTnT concentrations and right ventricular end-systolic volume index and right ventricular ejection fraction (RVEF) were +0.368 (P=0.046) and -0.381 (P=0.018), respectively. The sex- and age-adjusted hazard ratio for the primary outcome of hs-cTnT at 2 and 4 times the reference level (5 ng/L) were 2.89 (95% CI, 1.14-7.29) and 4.42 (95% CI, 1.21-16.15), respectively. The prognostic performance quantified by the concordance statistics for age- and sex-adjusted models based on hs-cTnT, right ventricular ejection fraction, and peak oxygen uptake predicted were comparable: 0.71% (95% CI, 0.61-0.82), 0.72% (95% CI, 0.59-0.84), and 0.71% (95% CI, 0.59-0.83), respectively. CONCLUSIONS: Hs-cTnT concentration was significantly correlated with right ventricular ejection fraction and right ventricular end-systolic volume index in patients with a systemic right ventricle. The prognostic accuracy of hs-cTnT was comparable to that of right ventricular ejection fraction and peak oxygen uptake predicted. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03049540.


Subject(s)
Biomarkers , Stroke Volume , Troponin T , Ventricular Dysfunction, Right , Ventricular Function, Right , Humans , Troponin T/blood , Female , Male , Middle Aged , Adult , Ventricular Function, Right/physiology , Stroke Volume/physiology , Prognosis , Ventricular Dysfunction, Right/physiopathology , Ventricular Dysfunction, Right/blood , Ventricular Dysfunction, Right/diagnosis , Biomarkers/blood , Phosphodiesterase 5 Inhibitors/therapeutic use , Heart Failure/blood , Heart Failure/physiopathology , Heart Failure/drug therapy , Heart Failure/diagnosis , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Predictive Value of Tests , Multidetector Computed Tomography , Proportional Hazards Models
6.
Medicina (Kaunas) ; 60(5)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38792878

ABSTRACT

Background and Objectives: The pancreas, ensconced within the abdominal cavity, requires a plethora of sophisticated imaging modalities for its comprehensive evaluation, with ultrasonography serving as a primary investigative technique. A myriad of pancreatic pathologies, encompassing pancreatic neoplasia and a spectrum of inflammatory diseases, are detectable through these imaging strategies. Nevertheless, the intricate anatomical confluence and the pancreas's deep-seated topography render the visualization and accurate diagnosis of its pathologies a formidable endeavor. The objective of our paper is to review the best diagnostic imagistic tools for the pancreas. Materials and Methods: we have gathered several articles using Prisma guidelines to determine the best imagistic methods. The imperative of pancreatic scanning transcends its diagnostic utility, proving to be a pivotal element in a multitude of clinical specialties, notably surgical oncology. Within this domain, multidetector computed tomography (MDCT) of the pancreas holds the distinction of being the paramount imaging modality, endorsed for its unrivaled capacity to delineate the staging and progression of pancreatic carcinoma. In synergy with MDCT, there has been a notable advent of avant-garde imaging techniques in recent years. These advanced methodologies, including ultrasonography, endoscopic ultrasonography, contrast-enhanced ultrasonography, and magnetic resonance imaging (MRI) conjoined with magnetic resonance cholangiopancreatography (MRCP), have broadened the horizon of tumor characterization, offering unparalleled depth and precision in oncological assessment. Other emerging diagnostic techniques, such as elastography, also hold a lot of potential and promise for the future of pancreatic imaging. Fine needle aspiration (FNA) is a quick, minimally invasive procedure to evaluate lumps using a thin needle to extract tissue for analysis. It is less invasive than surgical biopsies and usually performed as an outpatient with quick recovery. Its accuracy depends on sample quality, and the risks include minimal bleeding or discomfort. Results, guiding further treatment, are typically available within a week. Elastography is a non-invasive medical imaging technique that maps the elastic properties and stiffness of soft tissue. This method, often used in conjunction with ultrasound or MRI, helps differentiate between hard and soft areas in tissue, providing valuable diagnostic information. It is particularly useful for assessing liver fibrosis, thyroid nodules, breast lumps, and musculoskeletal conditions. The technique is painless and involves applying gentle pressure to the area being examined. The resulting images show tissue stiffness, indicating potential abnormalities. Elastography is advantageous for its ability to detect diseases in early stages and monitor treatment effectiveness. The procedure is quick, safe, and requires no special preparation, with results typically available immediately. Results: The assembled and gathered data shows the efficacy of various techniques in discerning the nature and extent of neoplastic lesions within the pancreas. Conclusions: The most common imaging modalities currently used in diagnosing pancreatic neoplasms are multidetector computed tomography (MDCT), endoscopic ultrasound (EUS), and magnetic resonance imaging (MRI), alongside new technologies, such as elastography.


Subject(s)
Pancreatic Neoplasms , Humans , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/diagnosis , Ultrasonography/methods , Magnetic Resonance Imaging/methods , Multidetector Computed Tomography/methods , Pancreas/diagnostic imaging , Pancreas/pathology
7.
J Forensic Odontostomatol ; 42(1): 38-57, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38742571

ABSTRACT

OBJECTIVES: This meta-analysis addresses the use of mandibular computed tomography (CT) scans for age and/or sex determination in forensic science. METHODS: Six databases were searched until June 2023, using the keyword "mandible" combined with keywords related to "multislice computed tomography" (MCT) or "cone-beam computed tomography" (CBCT) and keywords related to "skeletal age determination" or "sex determination analysis." MAIN RESULTS: Among the 23 studies included, 11 used MCT and 12 used CBCT to perform forensic assessments. Age determination was the aim of a single study, sex and agedeterminations were the objective of five studies, and the other studies investigated the determination of sex only. Metaanalysis could be performed only for sex determination. CONCLUSIONS: Mandible measurements are useful in sex determination, as the bicondylar and bigonial breadth are larger in males than in females. For the mandible angle, the meta-analysis results confirm sex dimorphism in CBCT scans but not in MCT scans. For age estimation, further studies are needed to prove that the mandible hole is a reliable parameter for age estimation. PROSPERO registration number: CRD42021260967.


Subject(s)
Age Determination by Skeleton , Cone-Beam Computed Tomography , Mandible , Sex Determination by Skeleton , Humans , Mandible/diagnostic imaging , Mandible/anatomy & histology , Sex Determination by Skeleton/methods , Age Determination by Skeleton/methods , Multidetector Computed Tomography , Forensic Anthropology/methods
8.
Medicina (Kaunas) ; 60(5)2024 May 10.
Article in English | MEDLINE | ID: mdl-38792977

ABSTRACT

Background and Objectives: Myocardial bridging (MB) is still not yet considered a significant finding in Indonesia both radiographically and clinically. Hence, this article aims to assess the prevalence of MB using multi-detector computed tomography (MDCT) and look at factors contributing to stenosis amongst patients with MB. Materials and Methods: This study is cross-sectional in a single centre, with consecutive sampling, looking at all patients who underwent a multi-detector computed tomography (MDCT) scan from February 2021 until February 2023. GraphPad Prism version 9.0.0 for Windows (GraphPad Software, Boston, MA, USA) was used to analyse the results. Results: There are 1029 patients with an MB, yielding a prevalence of 44.3% (95%CI 42.3-46.4). The left anterior descending vessel is the most commonly implicated, with 99.6%. Among those with stenosis, the middle portion of the bridging vessel is the most common site of stenosis (n = 269), followed by the proximal portion (n = 237). The severity of stenosis is more often moderate, with 30-50% (n = 238). Females (odds ratio [OR] of 1.8, 95%CI 1.4-2.3; p-value < 0.0001), older age (t-value 5.6, p-value < 0.0001), symptomatic patients (OR 1.4, 95% CI 1.1-1.9; p-value = 0.013), and higher mean coronary artery calcium score (t-value 11.3, p-value < 0.0001) are more likely to have stenosis. The degree of stenosis is significantly higher in the proximal stenosis group than in the middle stenosis group (t-value 27, p-value < 0.0001). Conclusions: Our research demonstrates that MB may prevent atheromatosis of the coronary segment distal to the MB and predispose the development of atherosclerosis in the section proximal to the bridge.


Subject(s)
Multidetector Computed Tomography , Myocardial Bridging , Humans , Indonesia/epidemiology , Female , Male , Middle Aged , Cross-Sectional Studies , Prevalence , Myocardial Bridging/epidemiology , Myocardial Bridging/diagnostic imaging , Multidetector Computed Tomography/methods , Adult , Aged , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/epidemiology
9.
Catheter Cardiovasc Interv ; 103(6): 995-1003, 2024 May.
Article in English | MEDLINE | ID: mdl-38662126

ABSTRACT

BACKGROUND: Limited data exists regarding incidence, progression, and predictors of left atrial appendage (LAA) sealing after transcatheter LAA closure. We aimed to evaluate the incidence, progression, and predictive factors associated with LAA sealing after LAA closure. METHODS: This study includes patients who underwent successful LAA closure with Watchman FLX device and had both pre- and postprocedural computed tomography (CT). Postprocedural CT was performed 45 days after LAA closure and used to evaluate residual LAA patency. Patient who had residual LAA patency at 45 days underwent 1-year follow-up CT. RESULTS: A total of 105 patients (mean age: 75.2 ± 9.6 years; 53.3% female) who underwent successful LAA closure with Watchman FLX device and had pre- and postprocedural CT at 45 days were included. Residual patency was observed in 35 (33.3%) patients: 21 (20.0%) patients showed complete contrast opacification in LAA (complete LAA patency) while 14 (13.3%) patients showed contrast opacification only in the distal LAA (distal LAA patency). Among patients with residual LAA patency at 45 days, the rate of LAA sealing at 1 year was significantly higher in the distal LAA patency group than in the complete LAA patency group (75.0% vs. 16.7%; p = 0.019). Increased depth oversizing was associated with both distal LAA patency and complete LAA patency. CONCLUSION: Postprocedural CT at 45 days detected patent LAA in one-third of patients after LAA closure. LAA sealing was more frequently observed at 1 year among the distal LAA patency group than the complete LAA patency group.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Catheterization , Predictive Value of Tests , Prosthesis Design , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Female , Male , Aged , Aged, 80 and over , Risk Factors , Treatment Outcome , Time Factors , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/therapy , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Retrospective Studies , Incidence , Tomography, X-Ray Computed , Multidetector Computed Tomography
11.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38652090

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using very high-power short-duration (vHPSD) radiofrequency (RF) ablation proved to be safe and effective. However, vHPSD applications result in shallower lesions that might not be always transmural. Multidetector computed tomography-derived left atrial wall thickness (LAWT) maps could enable a thickness-guided switching from vHPSD to the standard-power ablation mode. The aim of this randomized trial was to compare the safety, the efficacy, and the efficiency of a LAWT-guided vHPSD PVI approach with those of the CLOSE protocol for PAF ablation (NCT04298177). METHODS AND RESULTS: Consecutive patients referred for first-time PAF ablation were randomized on a 1:1 basis. In the QDOT-by-LAWT arm, for LAWT ≤2.5 mm, vHPSD ablation was performed; for points with LAWT > 2.5 mm, standard-power RF ablation titrating ablation index (AI) according to the local LAWT was performed. In the CLOSE arm, LAWT information was not available to the operator; ablation was performed according to the CLOSE study settings: AI ≥400 at the posterior wall and ≥550 at the anterior wall. A total of 162 patients were included. In the QDOT-by-LAWT group, a significant reduction in procedure time (40 vs. 70 min; P < 0.001) and RF time (6.6 vs. 25.7 min; P < 0.001) was observed. No difference was observed between the groups regarding complication rate (P = 0.99) and first-pass isolation (P = 0.99). At 12-month follow-up, no significant differences occurred in atrial arrhythmia-free survival between groups (P = 0.88). CONCLUSION: LAWT-guided PVI combining vHPSD and standard-power ablation is not inferior to the CLOSE protocol in terms of 1-year atrial arrhythmia-free survival and demonstrated a reduction in procedural and RF times.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Atria , Multidetector Computed Tomography , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Female , Male , Catheter Ablation/methods , Middle Aged , Aged , Heart Atria/surgery , Heart Atria/diagnostic imaging , Time Factors , Treatment Outcome , Recurrence , Heart Rate , Action Potentials
12.
Yonsei Med J ; 65(5): 257-264, 2024 May.
Article in English | MEDLINE | ID: mdl-38653564

ABSTRACT

PURPOSE: In a preclinical study using a swine myocardial infarction (MI) model, a delayed enhancement (DE)-multi-detector computed tomography (MDCT) scan was performed using a hybrid system alongside diagnostic invasive coronary angiography (ICA) without the additional use of a contrast agent, and demonstrated an excellent correlation in the infarct area compared with histopathologic specimens. In the present investigation, we evaluated the feasibility and diagnostic accuracy of a myocardial viability assessment by DE-MDCT using a hybrid system comprising ICA and MDCT alongside diagnostic ICA without the additional use of a contrast agent. MATERIALS AND METHODS: We prospectively enrolled 13 patients (median age: 67 years) with a previous MI (>6 months) scheduled to undergo ICA. All patients underwent cardiac magnetic resonance (CMR) imaging before diagnostic ICA. MDCT viability scans were performed concurrently with diagnostic ICA without the use of additional contrast. The total myocardial scar volume per patient and average transmurality per myocardial segment measured by DE-MDCT were compared with those from DE-CMR. RESULTS: The DE volume measured by MDCT showed an excellent correlation with the volume measured by CMR (r=0.986, p<0.0001). The transmurality per segment by MDCT was well-correlated with CMR (r=0.900, p<0.0001); the diagnostic performance of MDCT in differentiating non-viable from viable myocardium using a 50% transmurality criterion was good with a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 87.5%, 99.5%, 87.5%, 99.5%, and 99.1%, respectively. CONCLUSION: The feasibility of the DE-MDCT viability assessment acquired simultaneously with conventional ICA was proven in patients with chronic MI using DE-CMR as the reference standard.


Subject(s)
Coronary Angiography , Myocardial Infarction , Humans , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/pathology , Aged , Coronary Angiography/methods , Male , Female , Middle Aged , Prospective Studies , Magnetic Resonance Imaging/methods , Tomography, X-Ray Computed/methods , Multidetector Computed Tomography/methods
13.
J Craniofac Surg ; 35(4): e380-e385, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38651860

ABSTRACT

OBJECTIVE: The neck region is a common site for solitary cystic neck mass (SCNM) of various etiologies, including congenital, inflammatory, and neoplastic. In adults, the primary focus is excluding malignancy. The objective of this study was to retrospectively analyze the accuracy of available diagnostic technologies for the differentiation of benign and malignant SCNM in adult patients. The study aimed to develop new clinical practice guidelines for evaluating and managing SCNM. METHODS: The primary predictive variables were the diagnostic utilities of fine-needle aspiration cytology (FNAC), ultrasound (U/S), multislice computed tomography, and magnetic resonance imaging. The study's endpoint was the overall diagnostic accuracy in differentiating between benign and malignant SCNM. The final diagnosis was based on histopathology. RESULTS: The study included 79 adult patients: 55 (69.62%) male and 24 (30.38%) female ( P <0.05). The mean age at presentation was 42.1 years (range: 18-84 years). Solitary cystic neck mass was distributed in the anterior neck region in 30 (37.97%) patients and the posterolateral neck regions in 49 (62.03%) patients ( P <0.05). The posterolateral neck regions had a significantly higher rate of malignant SCNM than the anterior neck region [19/49 (38.78%) versus 1/30 (3.33%)] ( P <0.05). There was no statistically significant difference between the U/S+FNAC and U/S+FNAC+multislice computed tomography and/or magnetic resonance imaging groups in differentiating benign and malignant SCNM (40/42 versus 36/37, P >0.05). "Violated neck" was recorded in 2 cases. CONCLUSION: A systematic investigation protocol should be applied to evaluate adult patients with SCNM.


Subject(s)
Head and Neck Neoplasms , Magnetic Resonance Imaging , Ultrasonography , Humans , Male , Female , Adult , Middle Aged , Head and Neck Neoplasms/pathology , Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/therapy , Aged , Retrospective Studies , Aged, 80 and over , Adolescent , Biopsy, Fine-Needle , Diagnosis, Differential , Neck/diagnostic imaging , Neck/pathology , Practice Guidelines as Topic , Multidetector Computed Tomography , Young Adult , Cysts/diagnostic imaging , Cysts/pathology
14.
Radiographics ; 44(5): e230115, 2024 May.
Article in English | MEDLINE | ID: mdl-38662586

ABSTRACT

Adrenal vein sampling (AVS) is the standard method for distinguishing unilateral from bilateral sources of autonomous aldosterone production in patients with primary aldosteronism. This procedure has been performed at limited specialized centers due to its technical complexity. With recent advances in imaging technology and knowledge of adrenal vein anatomy in parallel with the development of adjunctive techniques, AVS has become easier to perform, even at nonspecialized centers. Although rare, anatomic variants of the adrenal veins can cause sampling failure or misinterpretation of the sampling results. The inferior accessory hepatic vein and the inferior emissary vein are useful anatomic landmarks for right adrenal vein cannulation, which is the most difficult and crucial step in AVS. Meticulous assessment of adrenal vein anatomy on multidetector CT images and the use of a catheter suitable for the anatomy are crucial for adrenal vein cannulation. Adjunctive techniques such as intraprocedural cortisol assay, cone-beam CT, and coaxial guidewire-catheter techniques are useful tools to confirm right adrenal vein cannulation or to troubleshoot difficult blood sampling. Interventional radiologists should be involved in interpreting the sampling results because technical factors may affect the results. In rare instances, bilateral adrenal suppression, in which aldosterone-to-cortisol ratios of both adrenal glands are lower than that of the inferior vena cava, can be encountered. Repeat sampling may be necessary in this situation. Collaboration with endocrinology and laboratory medicine services is of great importance to optimize the quality of the samples and for smooth and successful operation. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material.


Subject(s)
Adrenal Glands , Hyperaldosteronism , Humans , Adrenal Glands/blood supply , Adrenal Glands/diagnostic imaging , Aldosterone/blood , Anatomic Landmarks , Hepatic Veins/diagnostic imaging , Hyperaldosteronism/diagnostic imaging , Multidetector Computed Tomography/methods , Radiography, Interventional/methods , Veins/diagnostic imaging
16.
Radiology ; 310(3): e231429, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38530172

ABSTRACT

Background Differentiating between benign and malignant vertebral fractures poses diagnostic challenges. Purpose To investigate the reliability of CT-based deep learning models to differentiate between benign and malignant vertebral fractures. Materials and Methods CT scans acquired in patients with benign or malignant vertebral fractures from June 2005 to December 2022 at two university hospitals were retrospectively identified based on a composite reference standard that included histopathologic and radiologic information. An internal test set was randomly selected, and an external test set was obtained from an additional hospital. Models used a three-dimensional U-Net encoder-classifier architecture and applied data augmentation during training. Performance was evaluated using the area under the receiver operating characteristic curve (AUC) and compared with that of two residents and one fellowship-trained radiologist using the DeLong test. Results The training set included 381 patients (mean age, 69.9 years ± 11.4 [SD]; 193 male) with 1307 vertebrae (378 benign fractures, 447 malignant fractures, 482 malignant lesions). Internal and external test sets included 86 (mean age, 66.9 years ± 12; 45 male) and 65 (mean age, 68.8 years ± 12.5; 39 female) patients, respectively. The better-performing model of two training approaches achieved AUCs of 0.85 (95% CI: 0.77, 0.92) in the internal and 0.75 (95% CI: 0.64, 0.85) in the external test sets. Including an uncertainty category further improved performance to AUCs of 0.91 (95% CI: 0.83, 0.97) in the internal test set and 0.76 (95% CI: 0.64, 0.88) in the external test set. The AUC values of residents were lower than that of the best-performing model in the internal test set (AUC, 0.69 [95% CI: 0.59, 0.78] and 0.71 [95% CI: 0.61, 0.80]) and external test set (AUC, 0.70 [95% CI: 0.58, 0.80] and 0.71 [95% CI: 0.60, 0.82]), with significant differences only for the internal test set (P < .001). The AUCs of the fellowship-trained radiologist were similar to those of the best-performing model (internal test set, 0.86 [95% CI: 0.78, 0.93; P = .39]; external test set, 0.71 [95% CI: 0.60, 0.82; P = .46]). Conclusion Developed models showed a high discriminatory power to differentiate between benign and malignant vertebral fractures, surpassing or matching the performance of radiology residents and matching that of a fellowship-trained radiologist. © RSNA, 2024 See also the editorial by Booz and D'Angelo in this issue.


Subject(s)
Deep Learning , Spinal Fractures , Humans , Female , Male , Aged , Reproducibility of Results , Retrospective Studies , Spinal Fractures/diagnostic imaging , Multidetector Computed Tomography , Hospitals, University
17.
Zhonghua Wei Chang Wai Ke Za Zhi ; 27(3): 268-273, 2024 Mar 25.
Article in Chinese | MEDLINE | ID: mdl-38532589

ABSTRACT

Objective: To evaluate the relationships between the location and extent of diffusion of free intraperitoneal air by multi-slice spiral CT (MSCT) and between the location and size of acute gastrointestinal perforation. Methods: This was a descriptive case series. We examined abdominal CT images of 33 patients who were treated for intraoperatively confirmed gastrointestinal perforation (excluding appendiceal perforation) in the Department of General Surgery, Nanfang Hospital between January and September 2022. We identified five locations of intraperitoneal air: the subphrenic space, hepatic portal space, mid-abdominal wall, mesenteric space, and pelvic cavity. We allocated the 33 patients to an upper gastrointestinal perforation (n=23) and lower gastrointestinal perforation group (n=10) base on intraoperative findings and analyzed the relationships between the locations of free gas and of gastrointestinal perforation. Additionally, we established two models for analyzing the extent of diffusion of free gas in the abdominal cavity and constructed receiver operating characteristic (ROC) curves to analyze the relationships between the two models and the size of the gastrointestinal perforation. Results: In the upper gastrointestinal perforation group, free gas was located around the hepatic portal area in 91.3% (21/23) of patients: this is a significantly greater proportion than that found in the lower gastrointestinal perforation group (5/10) (P=0.016). In contrast, free gas was located in the mesenteric interspace in 8/10 patients in the lower gastrointestinal perforation group; this is a significantly greater proportion than was found in the upper gastrointestinal perforation group (8.7%, 2/23) (P<0.010). The sensitivity of diagnosis of upper gastrointestinal perforation base on the presence of hepatic portal free gas was 84.8% and the specificity 71.4%. Further, the sensitivity of diagnosis of lower gastrointestinal perforation base on the presence of mesenteric interspace free gas was 80.0% and the specificity 91.3%. The rates of presence of free gas in the subdiaphragmatic area, mid-abdominal wall, and pelvic cavity did not differ significantly between the two groups (all P>0.05). Receiver operating characteristic curves showed that when free gas was present in four or more of the studied locations in the abdominal cavity, the optimal cutoff for perforation diameter was 2 cm, the corresponding sensitivity 66.7%, and the specificity 100%, suggesting that abdominal free gas diffuses extensively when the diameter of the perforation is >2 cm. Another model revealed that when free gas is present in three or more of the studied locations, the optimal cutoff for perforation diameter is 1 cm, corresponding to a sensitivity of 91.7% and specificity of 76.2%; suggesting that free gas is relatively confined in the abdominal cavity when the diameter of the perforation is <1 cm. Conclusion: Identifying which of five locations in the abdominal cavity contains free intraperitoneal air by examining MSCT images can be used to assist in the diagnosis of the location and size of acute gastrointestinal perforations.


Subject(s)
Abdominal Cavity , Intestinal Perforation , Upper Gastrointestinal Tract , Humans , Multidetector Computed Tomography , Tomography, Spiral Computed , Liver , Retrospective Studies
18.
JACC Cardiovasc Interv ; 17(6): 715-726, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38456886

ABSTRACT

BACKGROUND: Coronary alignment is proposed as an alternative to commissural alignment for reducing coronary overlap during transcatheter aortic valve replacement (TAVR). However, largescale studies are lacking. OBJECTIVES: This study aimed to determine the incidence of coronary overlap with commissural vs coronary alignment using computed tomography (CT) simulation in patients undergoing TAVR evaluation. METHODS: In 1,851 CT scans of native aortic stenosis patients undergoing TAVR evaluation (April 2018 to December 2022),virtual valves simulating commissural and coronary alignment were superimposed on axial aortic root images. Coronary overlap was assessed based on the angular gap between coronary artery origin and the nearest transcatheter heart valve commissure, categorized as severe (≤15°), moderate (15°-30°), mild (30°-45°), and no-overlap (45°-60°). RESULTS: The overall incidence of moderate/severe and severe overlap with either coronary artery remained rare with either coronary or commissural alignment (coronary 0.52% left, 0.52% right; commissural 0.30% left, 3.27% right). Comparing techniques, coronary alignment reduced moderate/severe overlap only for the right coronary artery (0.38% vs 2.97%; P <0.0001). For the left coronary artery, both techniques showed similar moderate/severe overlap, but commissural alignment had significantly higher no-overlap rates (91.1% vs 84.9%; P < 0.0001). Fluoroscopic angle during valve deployment was strongly correlated between commissural and coronary alignment (r = 0.80; P < 0.001). CONCLUSIONS: Using CT simulation, the incidence of coronary overlap with transcatheter heart valve-commissure is rare with commissural alignment. Coronary alignment reduced right coronary overlap, whereas commissural alignment had higher rates of no left coronary overlap. Coronary alignment should be reserved only when commissural alignment results in severe coronary overlap.


Subject(s)
Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Treatment Outcome , Multidetector Computed Tomography
19.
J Am Heart Assoc ; 13(6): e033233, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38497463

ABSTRACT

BACKGROUND: Nonobstructive general angioscopy (NOGA) can identify vulnerable plaques in the aortic lumen that serve as potential risk factors for cardiovascular events such as embolism. However, the association between computed tomography (CT) images and vulnerable plaques detected on NOGA remains unknown. METHODS AND RESULTS: We investigated 101 patients (67±11 years; women, 13.8%) who underwent NOGA and contrast-enhanced CT before or after 90 days in our hospital. On CT images, the aortic wall thickness, aortic wall area (AWA), and AWA in the vascular area were measured at the thickest point from the 6th to the 12th thoracic vertebral levels. Furthermore, the association between these measurements and the presence or absence of NOGA-derived aortic plaque ruptures (PRs) at the same vertebral level was assessed. NOGA detected aortic PRs in the aortic lumens at 145 (22.1%) of the 656 vertebral levels. The presence of PRs was significantly associated with greater aortic wall thickness (3.3±1.7 mm versus 2.1±1.2 mm), AWA (1.33±0.68 cm2 versus 0.89±0.49 cm2), and AWA in the vascular area (23.2%±9.3% versus 17.2%±7.6%) (P<0.001 for all) on the CT scans compared with the absence of PRs. The frequency of PRs significantly increased as the aortic wall thickness increased. Notably, a few NOGA-derived PRs were detected on CT in near-normal intima. CONCLUSIONS: The presence of NOGA-derived PRs was strongly associated with increased aortic wall thickness, AWA, and AWA in the vascular area, measured using CT. NOGA can detect PRs in the intima that appear almost normal on CT scans.


Subject(s)
Multidetector Computed Tomography , Plaque, Atherosclerotic , Humans , Female , Angioscopy/methods , Aorta, Thoracic , Aorta
20.
Radiol Clin North Am ; 62(3): 419-434, 2024 May.
Article in English | MEDLINE | ID: mdl-38553178

ABSTRACT

The range of potential transcatheter solutions to valve disease is increasing, bringing treatment options to those in whom surgery confers prohibitively high risk. As the range of devices and their indications grow, so too will the demand for procedural planning. Computed tomography will continue to enable this growth through the provision of accurate device sizing and procedural risk assessment.


Subject(s)
Aortic Valve , Tomography, X-Ray Computed , Humans , Aortic Valve/surgery , Tomography, X-Ray Computed/methods , Risk Assessment , Treatment Outcome , Multidetector Computed Tomography/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...