Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 8.864
Filter
1.
World J Gastroenterol ; 30(23): 3005-3015, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38946876

ABSTRACT

BACKGROUND: Gastric cancer (GC) is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide. The disease poses a serious public health problem in China, ranking fifth for incidence and third for mortality. Knowledge of the invasive depth of the tumor is vital to treatment decisions. AIM: To evaluate the diagnostic performance of double contrast-enhanced ultrasonography (DCEUS) for preoperative T staging in patients with GC by comparing with multi-detector computed tomography (MDCT). METHODS: This single prospective study enrolled patients with GC confirmed by preoperative gastroscopy from July 2021 to March 2023. Patients underwent DCEUS, including ultrasonography (US) and intravenous contrast-enhanced ultrasonography (CEUS), and MDCT examinations for the assessment of preoperative T staging. Features of GC were identified on DCEUS and criteria developed to evaluate T staging according to the 8th edition of AJCC cancer staging manual. The diagnostic performance of DCEUS was evaluated by comparing it with that of MDCT and surgical-pathological findings were considered as the gold standard. RESULTS: A total of 229 patients with GC (80 T1, 33 T2, 59 T3 and 57 T4) were included. Overall accuracies were 86.9% for DCEUS and 61.1% for MDCT (P < 0.001). DCEUS was superior to MDCT for T1 (92.5% vs 70.0%, P < 0.001), T2 (72.7% vs 51.5%, P = 0.041), T3 (86.4% vs 45.8%, P < 0.001) and T4 (87.7% vs 70.2%, P = 0.022) staging of GC. CONCLUSION: DCEUS improved the diagnostic accuracy of preoperative T staging in patients with GC compared with MDCT, and constitutes a promising imaging modality for preoperative evaluation of GC to aid individualized treatment decision-making.


Subject(s)
Contrast Media , Multidetector Computed Tomography , Neoplasm Staging , Stomach Neoplasms , Ultrasonography , Humans , Stomach Neoplasms/diagnostic imaging , Stomach Neoplasms/pathology , Stomach Neoplasms/surgery , Middle Aged , Male , Female , Contrast Media/administration & dosage , Prospective Studies , Aged , Ultrasonography/methods , Ultrasonography/statistics & numerical data , Multidetector Computed Tomography/methods , Adult , China/epidemiology , Gastroscopy/methods , Stomach/diagnostic imaging , Stomach/pathology , Stomach/surgery , Aged, 80 and over
2.
BMC Surg ; 24(1): 190, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38886699

ABSTRACT

INTRODUCTION: To explore the diagnostic value of high-resolution ultrasound combined with multi-slice computer tomography (MSCT) for pediatric intra-abdominal hernias (IAHs), and to analyze the potential causes for missed diagnosis and misdiagnosis of IAHs in children. METHODS: A retrospective analysis was conducted on 45 children with surgically confirmed IAHs. The diagnostic rate of IAHs by preoperative high-resolution ultrasound combined with MSCT was compared with that of intraoperative examination, and the potential causes for missed diagnosis and misdiagnosis by the combination method were analyzed. RESULTS: Forty-five cases of pediatric IAHs were categorized into primary (25/45, 55.5%) and acquired secondary hernias (20/45, 44.5%). Among children with primary hernias, mesenteric defects were identified as the predominant subtype (40%). Acquired secondary hernias typically resulted from abnormal openings in the abdominal wall or band adhesions due to trauma, surgery, or inflammation. In particular, adhesive band hernias were the major type in children with acquired secondary hernias (40%). The diagnostic rate of high-resolution ultrasound was 77.8%, with "cross sign" as a characteristic ultrasonic feature. Among 10 cases of missed diagnosis or misdiagnosis, 5 were finally diagnosed as IAHs by multi-slice computer tomography (MSCT). Overall, the diagnostic rate of pediatric IAHs by preoperative ultrasound combined with radiological imaging reached 88.9%. DISCUSSION: IAHs in children, particularly mesenteric defects, are prone to strangulated intestinal obstruction and necrosis. High-resolution ultrasound combined with MSCT greatly enhances the diagnostic accuracy of pediatric IAHs.


Subject(s)
Hernia, Abdominal , Multidetector Computed Tomography , Ultrasonography , Humans , Retrospective Studies , Male , Female , Child, Preschool , Ultrasonography/methods , Child , Hernia, Abdominal/diagnostic imaging , Hernia, Abdominal/diagnosis , Infant , Multidetector Computed Tomography/methods , Adolescent
3.
Acta Odontol Latinoam ; 37(1): 79-87, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38920129

ABSTRACT

Differentiating orofacial odontogenic pain/disorders from pain/disorders associated with maxillary sinusitis is important to avoid unnecessary dentalprocedures and to properly refer patients to colleagues/dentists and vice versa. AIM: To analyze the association between apical lesions and sinus changes and to evaluate the agreement between the diagnoses of an endodontist, a radiologist, an oral and maxillofacial surgeon, and an otolaryngologist. MATERIALS AND METHOD: 385 axial, coronal, and sagittal MSCT scans were selected using an image archiving andcommunication system (PACS). The examinations had been performed between 2018 and 2022. RESULTS: Apical lesions were observed in 36.10% of sinusitis cases, 73.8% of unilateralsinusitis cases, 48.7% of sinus floor discontinuity cases, and 67.2% of cases in which endodontic treatment had been performed. Agreement between the diagnoses made by the endodontist and those made by the other investigators was high for most study variables (k > 0.60). The exceptions were mucosal thickening, for which agreement between the endodontist and the other investigators was intermediate (k=0.397), and the presence of periapicallesions (k=0.010), previous endodontic treatment (k=0.013), and mucosal thickness (k=0.024), for which agreement between endodontists and radiologists was low. Conclusions: There was an association between sinus changes and apical lesions.


Diferenciar a dor/desordens odontogénicas orofaciais da dor/desordens as sociadas á sinusite maxilar é importante para evitar procedimentos odontológicos desnecessários e para encaminhar adequadamente os pacientes aos colegas/dentistas e vice-versa. OBJETIVO: Analisar a associagdo entre lesoes apicais e alteragóes sinusais e avaliar a concordáncia entre os diagnósticos de um endodontista, um radiologista, um cirurgido bucomaxilofacial e um otorrinolaringologista. MATERIAL E MÉTODO: foram avaliadas 385 imagens. RESULTADOS: Aslesoes apicais foram observadas em 36,10% dos casos de sinusite, em 73,8% dos casos de sinusite unilateral, em 48,7% dos casos de descontinuidade do assoalho do seio e em 67,2%odos casos em que o tratamento endodontico havia sido realizado. A concordancia entre os diagnósticos feitos pelo endodontista e os feitos pelos outros pesquisadores foi alta para a maioria das variáveis do estudo (k > 0,60). As excegoes foram o espessamento da mucosa, para o qual a concordáncia entre o endodontista e os outros pesquisadores foi intermediária (k=0,397) e a presenga delesoes periapicais (k=0,010), tratamento endodontico prévio (k=0,013) e espessura da mucosa (k=0,024), para os quais a concordáncia entre endodontistas e radiologistas foi baixa. CONCLUSÕES: Houve uma associagdo entre as alteragóes sinusais e aslesoes apicais.


Subject(s)
Multidetector Computed Tomography , Humans , Female , Male , Middle Aged , Multidetector Computed Tomography/methods , Adult , Periapical Diseases/diagnostic imaging , Maxillary Sinusitis/diagnostic imaging , Aged , Young Adult , Adolescent , Diagnosis, Differential
4.
Otol Neurotol ; 45(6): 662-670, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38865722

ABSTRACT

INTRODUCTION: Cochlear duct length (CDL) measurement plays a role in the context of individualized cochlear implant (CI) surgery regarding an individualized selection and implantation of the CI electrode carrier and an efficient postoperative anatomy-based fitting process. The level of detail of the preoperative temporal bone CT scan depends on the imaging modality with major impact on CDL measurements and CI electrode contact position determination. The aim of this study was to evaluate the accuracy of perioperative CDL measurements and electrode contact determination in photon-counting CT (PCCT). METHODS: Ten human fresh-frozen petrous bone specimens were examined with a first-generation PCCT. A clinically applicable radiation dose of 27.1 mGy was used. Scans were acquired before and after CI insertion. Postoperative measurement of the CDL was conducted using an otological planning software and 3D-curved multiplanar reconstruction. Investigation of electrode contact position was performed by two respective observers. Measurements were compared with a conventional multislice CT and to a high-resolution flat-panel volume CT with secondary reconstructions. RESULTS: Pre- and postoperative CDL measurements in PCCT images showed no significant difference to high-resolution flat-panel volume CT. Postoperative CI electrode contact determination was also as precise as the flat-panel CT-based assessment. PCCT and flat-panel volume CT were equivalent concerning interobserver variability. CONCLUSION: CDL measurement with PCCT was equivalent to flat-panel volume CT with secondary reconstructions. PCCT enabled highly precise postoperative CI electrode contact determination with substantial advantages over conventional multislice CT scanners.


Subject(s)
Cochlear Implantation , Humans , Cochlear Implantation/methods , Cochlear Duct/diagnostic imaging , Cochlear Duct/surgery , Tomography, X-Ray Computed/methods , Cochlear Implants , Photons , Petrous Bone/diagnostic imaging , Petrous Bone/surgery , Multidetector Computed Tomography/methods , Angiography/methods
5.
Sensors (Basel) ; 24(11)2024 May 30.
Article in English | MEDLINE | ID: mdl-38894336

ABSTRACT

The paranasal sinuses, a bilaterally symmetrical system of eight air-filled cavities, represent one of the most complex parts of the equine body. This study aimed to extract morphometric measures from computed tomography (CT) images of the equine head and to implement a clustering analysis for the computer-aided identification of age-related variations. Heads of 18 cadaver horses, aged 2-25 years, were CT-imaged and segmented to extract their volume, surface area, and relative density from the frontal sinus (FS), dorsal conchal sinus (DCS), ventral conchal sinus (VCS), rostral maxillary sinus (RMS), caudal maxillary sinus (CMS), sphenoid sinus (SS), palatine sinus (PS), and middle conchal sinus (MCS). Data were grouped into young, middle-aged, and old horse groups and clustered using the K-means clustering algorithm. Morphometric measurements varied according to the sinus position and age of the horses but not the body side. The volume and surface area of the VCS, RMS, and CMS increased with the age of the horses. With accuracy values of 0.72 for RMS, 0.67 for CMS, and 0.31 for VCS, the possibility of the age-related clustering of CT-based 3D images of equine paranasal sinuses was confirmed for RMS and CMS but disproved for VCS.


Subject(s)
Imaging, Three-Dimensional , Paranasal Sinuses , Horses , Animals , Cluster Analysis , Paranasal Sinuses/diagnostic imaging , Imaging, Three-Dimensional/methods , Multidetector Computed Tomography/methods , Algorithms
6.
Int Ophthalmol ; 44(1): 267, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38913238

ABSTRACT

PURPOSE: To assist in surgical planning in endoscopic approaches, we analyzed the morphometric measurements of the superior orbital fissure (SOF) and optic canal (OC) by three-dimensional multislice computed tomography (3D MDCT) and evaluated them according to age, gender, and lateralization. METHODS: The study analyzed 219 MDCT images (114 women, 105 men) from individuals aged 18-90. Measurements of SOF and OC were performed on 3D MDCT images in the axial plane and with 3D-Slicer software. RESULTS: The distance between the infraorbital foramen and the anterior entrance of the maxillary sinus (CBW) (p < 0.001), the distance between the CBW and the lateral point of the SOF (p = 0.001), and the Angle 1 (p = 0.028) were higher in women than in men. While the SOF length and on 3D the SOF width were higher in women than men (p < 0.001 and (p = 0.001, respectively), the lateral wall length OC was higher in men than women (p = 0.045). According to SOF classification, SOF length was highest in type II and lowest in type VIII (p = 0.025), SOF width was highest in type I and lowest in type VI (p < 0.001). No significant difference was found based on age groups and lateralization in all parameters. CONCLUSION: We found that as the SOF width increased, the SOF length also increased, and there was a statistically strong positive correlation. These findings can contribute to a more effective and safe operation by improving and updating surgeons' knowledge about safe distances to SOF in endoscopic procedures from a 3D MDCT perspective.


Subject(s)
Imaging, Three-Dimensional , Multidetector Computed Tomography , Orbit , Humans , Male , Female , Adult , Adolescent , Orbit/diagnostic imaging , Orbit/anatomy & histology , Young Adult , Middle Aged , Imaging, Three-Dimensional/methods , Aged , Multidetector Computed Tomography/methods , Aged, 80 and over , Retrospective Studies , Endoscopy/methods
7.
Sci Rep ; 14(1): 14269, 2024 06 20.
Article in English | MEDLINE | ID: mdl-38902369

ABSTRACT

Condylar resorption occurs in some cases after orthognathic surgery, and the risk factors associated with postoperative condylar head resorption have been extensively described. Nevertheless, even in cases with a combination of risk factors, postoperative condylar resorption may not appear. This study analyzed the microstructure and three-dimensional positional change of the condylar bone via imaging in patients who have undergone bimaxillary orthognathic surgery to determine whether the microstructure or condylar position differs between patients with and without postoperative condylar resorption. Among asymptomatic patients who underwent bimaxillary surgery between April 2021 and March 2022 at our department, 17 patients were analyzed, limited to "female," "skeletal Class II," and "high-angle cases," which are known risk factors for mandibular head resorption. Multidetector computed tomography was performed on these patients before and 6 months after surgery, and the bone microstructure of the condylar head and the three-dimensional positional changes of the condylar bone and the proximal bony fragments were compared with the presence of postoperative condyle resorption using the bone morphology software TRI/3D-BON. Patients with condylar bone abnormalities before surgery and those with high trabecular bone density can develop postoperative resorption if the condyle is misaligned by surgery.


Subject(s)
Bone Resorption , Mandibular Condyle , Orthognathic Surgical Procedures , Humans , Female , Mandibular Condyle/diagnostic imaging , Mandibular Condyle/pathology , Male , Adult , Bone Resorption/etiology , Bone Resorption/diagnostic imaging , Bone Resorption/pathology , Orthognathic Surgical Procedures/adverse effects , Young Adult , Orthognathic Surgery/methods , Multidetector Computed Tomography , Imaging, Three-Dimensional , Postoperative Complications/etiology , Postoperative Complications/diagnostic imaging
8.
Ital J Pediatr ; 50(1): 122, 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38926831

ABSTRACT

BACKGROUND: Arterial switch operation (ASO) is the standard surgical choice for D-transposition of great arteries (D-TGA). However, the implications of ASO on pulmonaries, coronaries, and aorta have not been adequately investigated. The current study evaluates arterial morphologic changes post-ASO at intermediate-term surveillance. METHODS: From May 2021 to May 2022, patients with D-TGA who underwent ASO for more than six months were recruited. Preoperative and operative data were collected. Patients were assessed using echocardiography (ECHO) and multislice CT angiography (MSCT) to evaluate pulmonary, coronary, and aortic arterial anatomy. RESULTS: Twenty patients were included with median age of 11 (10-23.25) days at ASO and 14 (7.25-32.75) months on last follow-up. Neo-aortic regurgitation was detected in 12(60%) and neo-pulmonary regurgitation in 3 (15%). Using ECHO, complete evaluation of pulmonary arteries (PAs) was not achieved in 35% and incomplete coronaries assessment in 40% of cases. No stenosis was detected in coronaries using MSCT, although coronary anomalies were found in 9/20 (45%). Dilated Aortic annulus was detected in 16/20 (80%), dilated aortic root in 18/20 (90%), and dilated sinotubular junction in 70%. Right PA stenosis was diagnosed in 10/20 (50%) and left PA(LPA) stenosis in 7/20 (35%). Although Z-score of PAs did not correlate with aortic data, LPA bending angle was positively correlated to neo-aortic root diameter and Z-score (rho = 0.65,p = 0.016; rho = 0.69,p = 0.01), respectively. CONCLUSION: Echocardiography alone is not a conclusive surveillance tool for detecting late post-ASO anatomic changes in D-TGA patients. Cardiac MSCT should be considered for comprehensive evaluation on the intermediate-term follow-up post-ASO to accurately track morphologic abnormalities in the aorta, pulmonary, and coronary arteries.


Subject(s)
Arterial Switch Operation , Echocardiography , Multidetector Computed Tomography , Pulmonary Artery , Transposition of Great Vessels , Humans , Male , Female , Transposition of Great Vessels/diagnostic imaging , Transposition of Great Vessels/surgery , Infant , Infant, Newborn , Arterial Switch Operation/adverse effects , Pulmonary Artery/diagnostic imaging , Child, Preschool , Coronary Vessels/diagnostic imaging , Aorta/diagnostic imaging , Retrospective Studies , Computed Tomography Angiography , Follow-Up Studies
9.
Int J Cardiovasc Imaging ; 40(6): 1377-1388, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38722507

ABSTRACT

To assess the impact of low-dose contrast media (CM) injection protocol with deep learning image reconstruction (DLIR) algorithm on image quality in coronary CT angiography (CCTA). In this prospective study, patients underwent CCTA were prospectively and randomly assigned to three groups with different contrast volume protocols (at 320mgI/mL concentration and constant flow rate of 5ml/s). After pairing basic information, 210 patients were enrolled in this study: Group A, 0.7mL/kg (n = 70); Group B, 0.6mL/kg (n = 70); Group C, 0.5mL/kg (n = 70). All patients were examined via a prospective ECG-triggered scan protocol within one heartbeat. A high level DLIR (DLIR-H) algorithm was used for image reconstruction with a thickness and interval of 0.625mm. The CT values of ascending aorta (AA), descending aorta (DA), three main coronary arteries, pulmonary artery (PA), and superior vena cava (SVC) were measured and analyzed for objective assessment. Two radiologists assessed the image quality and diagnostic confidence using a 5-point Likert scale. The CM doses were 46.81 ± 6.41mL, 41.96 ± 7.51mL and 34.65 ± 5.38mL for Group A, B and C, respectively. The objective assessments on AA, DA and the three main coronary arteries and the overall subjective scoring showed no significant difference among the three groups (all p > 0.05). The subjective assessment proved that excellent CCTA images can be obtained from the three different contrast media protocols. There were no significant differences in intracoronary attenuation values between the higher HR subgroup and the lower HR subgroup among three groups. CCTA reconstructed with DLIR could be realized with adequate enhancement in coronary arteries, excellent image quality and diagnostic confidence at low contrast dose of a 0.5mL/kg. The use of lower tube voltages may further reduce the contrast dose requirement.


Subject(s)
Cardiac-Gated Imaging Techniques , Computed Tomography Angiography , Contrast Media , Coronary Angiography , Coronary Artery Disease , Coronary Vessels , Deep Learning , Electrocardiography , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted , Humans , Coronary Angiography/methods , Prospective Studies , Contrast Media/administration & dosage , Male , Female , Middle Aged , Aged , Coronary Vessels/diagnostic imaging , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Reproducibility of Results , Heart Rate , Radiation Dosage , Multidetector Computed Tomography
10.
J Am Heart Assoc ; 13(10): e034776, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38726920

ABSTRACT

BACKGROUND: The determinants and prognostic value of high-sensitivity cardiac troponin T (hs-cTnT) among patients with a systemic right ventricle are largely unknown. METHODS AND RESULTS: Ninety-eight patients from the randomized controlled SERVE (Effect of Phosphodiesterase-5 Inhibition With Tadalafil on Systemic Right Ventricular Size and Function) trial were included. The correlation between baseline hs-cTnT concentrations and biventricular volumes and function quantified by cardiac magnetic resonance or cardiac multirow detector computed tomography was assessed by adjusted linear regression models. The prognostic value of hs-cTnT was assessed by adjusted Cox proportional hazards models, survival analysis, and concordance statistics. The primary outcome was time to the composite of clinically relevant arrhythmia, hospitalization for heart failure, or all-cause death. Median age was 39 (interquartile range, 32-48) years, and 32% were women. Median hs-cTnT concentration was 7 (interquartile range, 4-11) ng/L. Coefficients of determination for the relationship between hs-cTnT concentrations and right ventricular end-systolic volume index and right ventricular ejection fraction (RVEF) were +0.368 (P=0.046) and -0.381 (P=0.018), respectively. The sex- and age-adjusted hazard ratio for the primary outcome of hs-cTnT at 2 and 4 times the reference level (5 ng/L) were 2.89 (95% CI, 1.14-7.29) and 4.42 (95% CI, 1.21-16.15), respectively. The prognostic performance quantified by the concordance statistics for age- and sex-adjusted models based on hs-cTnT, right ventricular ejection fraction, and peak oxygen uptake predicted were comparable: 0.71% (95% CI, 0.61-0.82), 0.72% (95% CI, 0.59-0.84), and 0.71% (95% CI, 0.59-0.83), respectively. CONCLUSIONS: Hs-cTnT concentration was significantly correlated with right ventricular ejection fraction and right ventricular end-systolic volume index in patients with a systemic right ventricle. The prognostic accuracy of hs-cTnT was comparable to that of right ventricular ejection fraction and peak oxygen uptake predicted. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03049540.


Subject(s)
Biomarkers , Stroke Volume , Troponin T , Ventricular Dysfunction, Right , Ventricular Function, Right , Humans , Troponin T/blood , Female , Male , Middle Aged , Adult , Ventricular Function, Right/physiology , Stroke Volume/physiology , Prognosis , Ventricular Dysfunction, Right/physiopathology , Ventricular Dysfunction, Right/blood , Ventricular Dysfunction, Right/diagnosis , Biomarkers/blood , Phosphodiesterase 5 Inhibitors/therapeutic use , Heart Failure/blood , Heart Failure/physiopathology , Heart Failure/drug therapy , Heart Failure/diagnosis , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Predictive Value of Tests , Multidetector Computed Tomography , Proportional Hazards Models
11.
Circ Cardiovasc Imaging ; 17(5): e016267, 2024 May.
Article in English | MEDLINE | ID: mdl-38771899

ABSTRACT

BACKGROUND: Aortic valve calcification (AVC) indexation to the aortic annulus (AA) area measured by Doppler echocardiography (AVCdEcho) provides powerful prognostic information in patients with aortic stenosis (AS). However, the indexation by AA measured by multidetector computed tomography (AVCdCT) has never been evaluated. The aim of this study was to compare AVC, AVCdCT, and AVCdEcho with regard to hemodynamic correlations and clinical outcomes in patients with AS. METHODS: Data from 889 patients, mainly White, with calcific AS who underwent Doppler echocardiography and multidetector computed tomography within the same episode of care were retrospectively analyzed. AA was measured both by Doppler echocardiography and multidetector computed tomography. AVCdCT severity thresholds were established using receiver operating characteristic curve analyses in men and women separately. The primary end point was the occurrence of all-cause mortality. RESULTS: Correlations between gradient/velocity and AVCd were stronger (both P≤0.005) using AVCdCT (r=0.68, P<0.001 and r=0.66, P<0.001) than AVC (r=0.61, P<0.001 and r=0.60, P<0.001) or AVCdEcho (r=0.61, P<0.001 and r=0.59, P<0.001). AVCdCT thresholds for the identification of severe AS were 334 Agatston units (AU)/cm2 for women and 467 AU/cm2 for men. On a median follow-up of 6.62 (6.19-9.69) years, AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict all-cause mortality in multivariate analyses (hazard ratio [HR], 1.59 [95% CI, 1.26-2.00]; P<0.001 versus HR, 1.53 [95% CI, 1.11-1.65]; P=0.003 versus HR, 1.27 [95% CI, 1.11-1.46]; P<0.001; all likelihood test P≤0.004). AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict survival under medical treatment in multivariate analyses (HR, 1.80 [95% CI, 1.27-1.58]; P<0.001 compared with HR, 1.55 [95% CI, 1.13-2.10]; P=0.007; HR, 1.28 [95% CI, 1.03-1.57]; P=0.01; all likelihood test P<0.03). AVCdCT ratio predicts mortality in all subgroups of patients with AS. CONCLUSIONS: AVCdCT appears to be equivalent or superior to AVC and AVCdEcho to assess AS severity and predict all-cause mortality. Thus, it should be used to evaluate AS severity in patients with nonconclusive echocardiographic evaluations with or without low-flow status. AVCdCT thresholds of 300 AU/cm2 for women and 500 AU/cm2 for men seem to be appropriate to identify severe AS. Further studies are needed to validate these thresholds, especially in diverse populations.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Calcinosis , Echocardiography, Doppler , Multidetector Computed Tomography , Predictive Value of Tests , Severity of Illness Index , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Male , Female , Multidetector Computed Tomography/methods , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Retrospective Studies , Aged , Calcinosis/diagnostic imaging , Calcinosis/physiopathology , Calcinosis/mortality , Echocardiography, Doppler/methods , Aged, 80 and over , Prognosis , ROC Curve , Hemodynamics , Middle Aged , Risk Factors
12.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38691562

ABSTRACT

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Septum , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Ventricular Septum/diagnostic imaging , Aged, 80 and over , Risk Factors , Aged , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnostic imaging , Heart Conduction System/physiopathology , Heart Conduction System/diagnostic imaging , Treatment Outcome , Predictive Value of Tests , Risk Assessment , Severity of Illness Index , Retrospective Studies , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Multidetector Computed Tomography , Tomography, X-Ray Computed , Action Potentials
13.
Tomography ; 10(5): 727-737, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38787016

ABSTRACT

PURPOSE: The purpose of this study was to analyze the prevalence of and complications resulting from temporal bone fractures in adult and pediatric patients evaluated for cranio-facial trauma in an emergency setting. METHODS: A retrospective blinded analysis of CT scans of a series of 294 consecutive adult and pediatric patients with cranio-facial trauma investigated in the emergency setting was conducted. Findings were compared between the two populations. Preliminary reports made by on-call residents were compared with the retrospective analysis, which was performed in consensus by two experienced readers and served as reference standard. RESULTS: CT revealed 126 fractures in 116/294 (39.5%) patients, although fractures were clinically suspected only in 70/294 (23.8%); p < 0.05. Fractures were longitudinal, transverse and mixed in 69.5%, 10.3% and 19.8% of cases, respectively. Most fractures were otic-sparing fractures (95.2%). Involvement of the external auditory canal, ossicular chain and the osseous structures surrounding the facial nerve was present in 72.2%, 8.7% and 6.3% of cases, respectively. Temporal bone fractures extended into the venous sinuses/jugular foramen and carotid canal in 18.3% and 17.5% of cases, respectively. Vascular injuries (carotid dissection and venous thrombosis) were more common in children than in adults (13.6% versus 5.3%); however, the observed difference did not reach statistical significance. 79.5% of patients with temporal bone fractures had both brain injuries and fractures of the facial bones and cranial vault. Brain injuries were more common in adults (90.4%) than in children (63.6%), p = 0.001. Although on-call residents reliably detected temporal bone fractures (sensitivity = 92.8%), they often missed trauma-associated ossicular dislocation (sensitivity = 27.3%). CONCLUSIONS: Temporal bone fractures and related complications are common in patients with cranio-facial trauma and need to be thoroughly looked for; the pattern of associated injuries is slightly different in children and in adults.


Subject(s)
Skull Fractures , Temporal Bone , Humans , Temporal Bone/diagnostic imaging , Temporal Bone/injuries , Male , Female , Adult , Child , Retrospective Studies , Skull Fractures/diagnostic imaging , Skull Fractures/complications , Adolescent , Middle Aged , Child, Preschool , Aged , Young Adult , Aged, 80 and over , Infant , Multidetector Computed Tomography/methods , Facial Injuries/diagnostic imaging , Prevalence , Emergency Service, Hospital , Craniocerebral Trauma/diagnostic imaging , Craniocerebral Trauma/complications , Tomography, X-Ray Computed/methods
14.
Medicina (Kaunas) ; 60(5)2024 May 10.
Article in English | MEDLINE | ID: mdl-38792977

ABSTRACT

Background and Objectives: Myocardial bridging (MB) is still not yet considered a significant finding in Indonesia both radiographically and clinically. Hence, this article aims to assess the prevalence of MB using multi-detector computed tomography (MDCT) and look at factors contributing to stenosis amongst patients with MB. Materials and Methods: This study is cross-sectional in a single centre, with consecutive sampling, looking at all patients who underwent a multi-detector computed tomography (MDCT) scan from February 2021 until February 2023. GraphPad Prism version 9.0.0 for Windows (GraphPad Software, Boston, MA, USA) was used to analyse the results. Results: There are 1029 patients with an MB, yielding a prevalence of 44.3% (95%CI 42.3-46.4). The left anterior descending vessel is the most commonly implicated, with 99.6%. Among those with stenosis, the middle portion of the bridging vessel is the most common site of stenosis (n = 269), followed by the proximal portion (n = 237). The severity of stenosis is more often moderate, with 30-50% (n = 238). Females (odds ratio [OR] of 1.8, 95%CI 1.4-2.3; p-value < 0.0001), older age (t-value 5.6, p-value < 0.0001), symptomatic patients (OR 1.4, 95% CI 1.1-1.9; p-value = 0.013), and higher mean coronary artery calcium score (t-value 11.3, p-value < 0.0001) are more likely to have stenosis. The degree of stenosis is significantly higher in the proximal stenosis group than in the middle stenosis group (t-value 27, p-value < 0.0001). Conclusions: Our research demonstrates that MB may prevent atheromatosis of the coronary segment distal to the MB and predispose the development of atherosclerosis in the section proximal to the bridge.


Subject(s)
Multidetector Computed Tomography , Myocardial Bridging , Humans , Indonesia/epidemiology , Female , Male , Middle Aged , Cross-Sectional Studies , Prevalence , Myocardial Bridging/epidemiology , Myocardial Bridging/diagnostic imaging , Multidetector Computed Tomography/methods , Adult , Aged , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/epidemiology
15.
Medicina (Kaunas) ; 60(5)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38792878

ABSTRACT

Background and Objectives: The pancreas, ensconced within the abdominal cavity, requires a plethora of sophisticated imaging modalities for its comprehensive evaluation, with ultrasonography serving as a primary investigative technique. A myriad of pancreatic pathologies, encompassing pancreatic neoplasia and a spectrum of inflammatory diseases, are detectable through these imaging strategies. Nevertheless, the intricate anatomical confluence and the pancreas's deep-seated topography render the visualization and accurate diagnosis of its pathologies a formidable endeavor. The objective of our paper is to review the best diagnostic imagistic tools for the pancreas. Materials and Methods: we have gathered several articles using Prisma guidelines to determine the best imagistic methods. The imperative of pancreatic scanning transcends its diagnostic utility, proving to be a pivotal element in a multitude of clinical specialties, notably surgical oncology. Within this domain, multidetector computed tomography (MDCT) of the pancreas holds the distinction of being the paramount imaging modality, endorsed for its unrivaled capacity to delineate the staging and progression of pancreatic carcinoma. In synergy with MDCT, there has been a notable advent of avant-garde imaging techniques in recent years. These advanced methodologies, including ultrasonography, endoscopic ultrasonography, contrast-enhanced ultrasonography, and magnetic resonance imaging (MRI) conjoined with magnetic resonance cholangiopancreatography (MRCP), have broadened the horizon of tumor characterization, offering unparalleled depth and precision in oncological assessment. Other emerging diagnostic techniques, such as elastography, also hold a lot of potential and promise for the future of pancreatic imaging. Fine needle aspiration (FNA) is a quick, minimally invasive procedure to evaluate lumps using a thin needle to extract tissue for analysis. It is less invasive than surgical biopsies and usually performed as an outpatient with quick recovery. Its accuracy depends on sample quality, and the risks include minimal bleeding or discomfort. Results, guiding further treatment, are typically available within a week. Elastography is a non-invasive medical imaging technique that maps the elastic properties and stiffness of soft tissue. This method, often used in conjunction with ultrasound or MRI, helps differentiate between hard and soft areas in tissue, providing valuable diagnostic information. It is particularly useful for assessing liver fibrosis, thyroid nodules, breast lumps, and musculoskeletal conditions. The technique is painless and involves applying gentle pressure to the area being examined. The resulting images show tissue stiffness, indicating potential abnormalities. Elastography is advantageous for its ability to detect diseases in early stages and monitor treatment effectiveness. The procedure is quick, safe, and requires no special preparation, with results typically available immediately. Results: The assembled and gathered data shows the efficacy of various techniques in discerning the nature and extent of neoplastic lesions within the pancreas. Conclusions: The most common imaging modalities currently used in diagnosing pancreatic neoplasms are multidetector computed tomography (MDCT), endoscopic ultrasound (EUS), and magnetic resonance imaging (MRI), alongside new technologies, such as elastography.


Subject(s)
Pancreatic Neoplasms , Humans , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/diagnosis , Ultrasonography/methods , Magnetic Resonance Imaging/methods , Multidetector Computed Tomography/methods , Pancreas/diagnostic imaging , Pancreas/pathology
16.
Clin Chest Med ; 45(2): 237-248, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38816085

ABSTRACT

The pericardium comprises a double-walled fibrous-serosal sac that encloses the heart. Reflections of the serosal layer form sinuses and recesses. With advances in multidetector computed tomography (CT) technology, pericardial recesses are frequently detected with thin-section CT. Knowledge of pericardial anatomy on imaging is crucial to avoid misinterpretation of fluid-filled pericardial sinuses and recesses as adenopathy/pericardial metastasis or aortic dissection, which can impact patient management and treatment decisions. The authors offer a comprehensive review of pericardial anatomy and its variations observed on CT, potential pitfalls in image interpretation, and implications for the pulmonologist with respect to unnecessary diagnostic procedures or interventions.


Subject(s)
Pericardium , Humans , Pericardium/diagnostic imaging , Tomography, X-Ray Computed , Pulmonologists , Multidetector Computed Tomography/methods
17.
J Forensic Odontostomatol ; 42(1): 38-57, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38742571

ABSTRACT

OBJECTIVES: This meta-analysis addresses the use of mandibular computed tomography (CT) scans for age and/or sex determination in forensic science. METHODS: Six databases were searched until June 2023, using the keyword "mandible" combined with keywords related to "multislice computed tomography" (MCT) or "cone-beam computed tomography" (CBCT) and keywords related to "skeletal age determination" or "sex determination analysis." MAIN RESULTS: Among the 23 studies included, 11 used MCT and 12 used CBCT to perform forensic assessments. Age determination was the aim of a single study, sex and agedeterminations were the objective of five studies, and the other studies investigated the determination of sex only. Metaanalysis could be performed only for sex determination. CONCLUSIONS: Mandible measurements are useful in sex determination, as the bicondylar and bigonial breadth are larger in males than in females. For the mandible angle, the meta-analysis results confirm sex dimorphism in CBCT scans but not in MCT scans. For age estimation, further studies are needed to prove that the mandible hole is a reliable parameter for age estimation. PROSPERO registration number: CRD42021260967.


Subject(s)
Age Determination by Skeleton , Cone-Beam Computed Tomography , Mandible , Sex Determination by Skeleton , Humans , Mandible/diagnostic imaging , Mandible/anatomy & histology , Sex Determination by Skeleton/methods , Age Determination by Skeleton/methods , Multidetector Computed Tomography , Forensic Anthropology/methods
18.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38652090

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using very high-power short-duration (vHPSD) radiofrequency (RF) ablation proved to be safe and effective. However, vHPSD applications result in shallower lesions that might not be always transmural. Multidetector computed tomography-derived left atrial wall thickness (LAWT) maps could enable a thickness-guided switching from vHPSD to the standard-power ablation mode. The aim of this randomized trial was to compare the safety, the efficacy, and the efficiency of a LAWT-guided vHPSD PVI approach with those of the CLOSE protocol for PAF ablation (NCT04298177). METHODS AND RESULTS: Consecutive patients referred for first-time PAF ablation were randomized on a 1:1 basis. In the QDOT-by-LAWT arm, for LAWT ≤2.5 mm, vHPSD ablation was performed; for points with LAWT > 2.5 mm, standard-power RF ablation titrating ablation index (AI) according to the local LAWT was performed. In the CLOSE arm, LAWT information was not available to the operator; ablation was performed according to the CLOSE study settings: AI ≥400 at the posterior wall and ≥550 at the anterior wall. A total of 162 patients were included. In the QDOT-by-LAWT group, a significant reduction in procedure time (40 vs. 70 min; P < 0.001) and RF time (6.6 vs. 25.7 min; P < 0.001) was observed. No difference was observed between the groups regarding complication rate (P = 0.99) and first-pass isolation (P = 0.99). At 12-month follow-up, no significant differences occurred in atrial arrhythmia-free survival between groups (P = 0.88). CONCLUSION: LAWT-guided PVI combining vHPSD and standard-power ablation is not inferior to the CLOSE protocol in terms of 1-year atrial arrhythmia-free survival and demonstrated a reduction in procedural and RF times.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Atria , Multidetector Computed Tomography , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Female , Male , Catheter Ablation/methods , Middle Aged , Aged , Heart Atria/surgery , Heart Atria/diagnostic imaging , Time Factors , Treatment Outcome , Recurrence , Heart Rate , Action Potentials
19.
Catheter Cardiovasc Interv ; 103(6): 995-1003, 2024 May.
Article in English | MEDLINE | ID: mdl-38662126

ABSTRACT

BACKGROUND: Limited data exists regarding incidence, progression, and predictors of left atrial appendage (LAA) sealing after transcatheter LAA closure. We aimed to evaluate the incidence, progression, and predictive factors associated with LAA sealing after LAA closure. METHODS: This study includes patients who underwent successful LAA closure with Watchman FLX device and had both pre- and postprocedural computed tomography (CT). Postprocedural CT was performed 45 days after LAA closure and used to evaluate residual LAA patency. Patient who had residual LAA patency at 45 days underwent 1-year follow-up CT. RESULTS: A total of 105 patients (mean age: 75.2 ± 9.6 years; 53.3% female) who underwent successful LAA closure with Watchman FLX device and had pre- and postprocedural CT at 45 days were included. Residual patency was observed in 35 (33.3%) patients: 21 (20.0%) patients showed complete contrast opacification in LAA (complete LAA patency) while 14 (13.3%) patients showed contrast opacification only in the distal LAA (distal LAA patency). Among patients with residual LAA patency at 45 days, the rate of LAA sealing at 1 year was significantly higher in the distal LAA patency group than in the complete LAA patency group (75.0% vs. 16.7%; p = 0.019). Increased depth oversizing was associated with both distal LAA patency and complete LAA patency. CONCLUSION: Postprocedural CT at 45 days detected patent LAA in one-third of patients after LAA closure. LAA sealing was more frequently observed at 1 year among the distal LAA patency group than the complete LAA patency group.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Catheterization , Predictive Value of Tests , Prosthesis Design , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Female , Male , Aged , Aged, 80 and over , Risk Factors , Treatment Outcome , Time Factors , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/therapy , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Retrospective Studies , Incidence , Tomography, X-Ray Computed , Multidetector Computed Tomography
20.
Int J Cardiovasc Imaging ; 40(6): 1201-1209, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38630211

ABSTRACT

This study assesses the agreement of Artificial Intelligence-Quantitative Computed Tomography (AI-QCT) with qualitative approaches to atherosclerotic disease burden codified in the multisociety 2022 CAD-RADS 2.0 Expert Consensus. 105 patients who underwent cardiac computed tomography angiography (CCTA) for chest pain were evaluated by a blinded core laboratory through FDA-cleared software (Cleerly, Denver, CO) that performs AI-QCT through artificial intelligence, analyzing factors such as % stenosis, plaque volume, and plaque composition. AI-QCT plaque volume was then staged by recently validated prognostic thresholds, and compared with CAD-RADS 2.0 clinical methods of plaque evaluation (segment involvement score (SIS), coronary artery calcium score (CACS), visual assessment, and CAD-RADS percent (%) stenosis) by expert consensus blinded to the AI-QCT core lab reads. Average age of subjects were 59 ± 11 years; 44% women, with 50% of patients at CAD-RADS 1-2 and 21% at CAD-RADS 3 and above by expert consensus. AI-QCT quantitative plaque burden staging had excellent agreement of 93% (k = 0.87 95% CI: 0.79-0.96) with SIS. There was moderate agreement between AI-QCT quantitative plaque volume and categories of visual assessment (64.4%; k = 0.488 [0.38-0.60]), and CACS (66.3%; k = 0.488 [0.36-0.61]). Agreement between AI-QCT plaque volume stage and CAD-RADS % stenosis category was also moderate. There was discordance at small plaque volumes. With ongoing validation, these results demonstrate a potential for AI-QCT as a rapid, reproducible approach to quantify total plaque burden.


Subject(s)
Artificial Intelligence , Computed Tomography Angiography , Coronary Angiography , Coronary Artery Disease , Coronary Stenosis , Plaque, Atherosclerotic , Predictive Value of Tests , Severity of Illness Index , Vascular Calcification , Humans , Female , Middle Aged , Male , Aged , Reproducibility of Results , Vascular Calcification/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted , Multidetector Computed Tomography , Observer Variation
SELECTION OF CITATIONS
SEARCH DETAIL
...