1.
Pain Manag Nurs ; 20(2): 158-163, 2019 04.
Article in English | MEDLINE | ID: mdl-30442567

ABSTRACT

BACKGROUND: Effective acute pain management following injury is critical to improve short-and long-term patient outcomes. Analgesics can effectively reduce pain intensity, yet half of injury patients report moderate to severe pain during hospitalization. PURPOSE: The primary aim of this study was to identify the analgesic, different analgesic combinations, or analgesic and adjuvant analgesic combination that generated the largest percent change from pre- to post-analgesic pain score. DESIGN: This was a descriptive retrospective cohort study of 129 adults admitted with lower extremity fractures to a trauma center. METHODS: Name, dose, and frequency of analgesics and adjuvant analgesics administered from admission to discharge were collected from medical records. Percent change was calculated from pain scores documented on the 0-10 numeric rating scale. RESULTS: The analgesic with largest percent change from pre- to post-administration pain score was hydromorphone 2 mg IV (53%) for the emergency department and morphine 4 mg IV (54%) for the in-patient unit. All analgesics administered in the emergency department and ∼50% administered on the in-patient unit produced a minimal (15%) decrease in pain score. CONCLUSIONS: This study revealed that few analgesics administered in the emergency department and the in-patient unit to patients with lower extremity fractures provide adequate pain relief. In the emergency department, all analgesics administered resulted in at least minimal improvement of pain. On the in-patient unit 13 analgesic doses resulted at least minimal improvement in pain while nine doses did not even reach 20% change in pain. Findings from this study can be used guide the treatment of fracture pain in the hospital.


Subject(s)
Analgesics/standards , Fractures, Bone/drug therapy , Pain Measurement/statistics & numerical data , Adult , Amitriptyline/analogs & derivatives , Amitriptyline/standards , Amitriptyline/therapeutic use , Analgesics/therapeutic use , Anticonvulsants/standards , Anticonvulsants/therapeutic use , Antidepressive Agents/standards , Antidepressive Agents/therapeutic use , Baclofen/standards , Baclofen/therapeutic use , Bones of Lower Extremity/drug effects , Bones of Lower Extremity/injuries , Cohort Studies , Duloxetine Hydrochloride/standards , Duloxetine Hydrochloride/therapeutic use , Female , Gabapentin/standards , Gabapentin/therapeutic use , Hospitalization/statistics & numerical data , Humans , Male , Middle Aged , Muscle Relaxants, Central/standards , Muscle Relaxants, Central/therapeutic use , Pain Management/methods , Pain Management/standards , Pain Measurement/methods , Pregabalin/standards , Pregabalin/therapeutic use , Retrospective Studies
2.
Neuromodulation ; 20(4): 397-404, 2017 Jun.
Article in English | MEDLINE | ID: mdl-27767242

ABSTRACT

BACKGROUND: Commercial baclofen formulations used with infusion pumps are available at therapeutic concentrations of 0.5-2.0 mg/mL. However, patients who receive higher daily doses of baclofen may benefit from products with greater baclofen concentrations since their refill frequency would be reduced (up to a maximum of 180 days). We evaluated baclofen solubility, baclofen 3 mg/mL intrathecal (IT) formulation stability, and chemical and physical compatibility with Medtronic SynchroMed® II and Codman Medstream® programmable IT infusion pumps. METHODS: For solubility evaluations, baclofen powder was dissolved into isotonic saline and tested at 5°C, 25°C, and 40°C. To demonstrate drug product stability, both physical and chemical stability attributes of baclofen 3 mg/mL in prefilled syringes were evaluated over 36 months with storage at 25°C. For a simulated in-use stability (compatibility) study, a 3 mg/mL baclofen IT formulation was placed in SynchroMed II and Codman Medstream pumps at 37ºC for study durations, and evaluated at different flow rates. Pump effluent was collected at various times and analyzed by high-performance liquid chromatography for baclofen content. On completion of the in-use stability study, pumps exposed to baclofen 3 mg/mL were dissected and visually evaluated for signs of deterioration. RESULTS: Baclofen solubility was found to be 3.2 mg/mL at 5°C, 3.6 mg/mL at 25°C, and 3.9 mg/mL at 40°C. During the 36-month stability study of prefilled syringes stored at 25°C, baclofen content remained unchanged and no precipitation was observed. The simulated in-use pump study performed at 37ºC showed that a baclofen 3 mg/mL IT formulation was stable at different flow rates and throughout different expected residence times for both pump models. Components from both pumps exhibited no noticeable deterioration after exposure to the 3 mg/mL formulation. CONCLUSION: Baclofen 3 mg/mL IT formulation was stable during long-term storage at 25°C and remained stable under conditions matching those encountered in clinical practice (37°C).


Subject(s)
Baclofen/chemistry , Baclofen/standards , Infusion Pumps, Implantable/standards , Muscle Relaxants, Central/chemistry , Muscle Relaxants, Central/standards , Baclofen/administration & dosage , Drug Compounding , Drug Stability , Drug Storage/standards , Humans , Injections, Spinal/methods , Injections, Spinal/standards , Solubility
3.
PM R ; 4(3): 182-9, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22322047

ABSTRACT

OBJECTIVE: To compare the quality of intrathecal baclofen obtained from a national compounding pharmacy (AnazaoHealth) with the manufactured product (Lioresal) with regard to accuracy and precision of baclofen concentration, and the content of the baclofen degradation product, 4-(4-chlorophenyl)-2-pyrrolidinone (PYR). DESIGN: Samples of baclofen used for refilling intrathecal pumps were placed in 1.2-mL silicone gasket-sealed cryogenic vials and stored at or lower than -25°C. Each sample was a different lot number (Lioresal) or prescription number (AnazaoHealth). The laboratory was blinded to the source of the solutions. Coupled with electrospray ionization-mass spectrometry analyte confirmation, quantitation of baclofen and PYR in each sample was performed in duplicate by using high-performance liquid chromatography with ultraviolet detection via a photodiode array detector. SETTING: Outpatient clinic. PARTICIPANTS: Patients with intrathecal baclofen pumps. MAIN OUTCOME MEASURES: Accuracy and precision of baclofen concentration, and concentration of PYR. RESULTS: The difference of mean concentrations from expected concentrations of 500 and 2000 µg/mL were significantly greater for samples from AnazaoHealth compared with Lioresal. Values are shown as mean (± standard error), with n the number samples, for AnazaoHealth compared with Lioresal: (537.1 ± 6.7 µg/mL [n = 8] versus 515.6 ± 0.82 µg/mL [n = 5]; P = .034, respectively) and (2211.4 ± 21.6 µg/mL [n = 12] versus 2055.3 ± 8.7 µg/mL [n = 4]; P = .004, respectively). AnazaoHealth samples with expected concentration of 4000 µg/mL were 3987.7 ± 79.9 µg/mL, n = 7. All 9 Lioresal samples were within 5% of the expected concentration. Of 27 AnazaoHealth samples, 22 were more than 5%, and 8 were more than 10% different from the expected concentration. No PYR was detected in any sample from AnazaoHealth. All samples of Lioresal contained PYR, but all solutions contained less PYR than 1% of the baclofen concentration. CONCLUSIONS: Lioresal was more accurate in concentration and more precise among batches than compounded intrathecal baclofen but had higher levels of PYR.


Subject(s)
Baclofen/standards , Muscle Relaxants, Central/standards , Muscle Spasticity/drug therapy , Adult , Baclofen/administration & dosage , Baclofen/chemistry , Chromatography, High Pressure Liquid , Female , Humans , Infusion Pumps , Injections, Spinal , Middle Aged , Muscle Relaxants, Central/administration & dosage , Muscle Relaxants, Central/chemistry , Reproducibility of Results , Spectrometry, Mass, Electrospray Ionization
4.
J Neurosurg ; 104(4 Suppl): 233-9, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16619633

ABSTRACT

In March 2004, a multidisciplinary conference, "ITB Therapy Best Practice Forum," was held in Minneapolis, Minnesota. The goal of the conference was to develop recommendations for techniques to implant intrathecal baclofen (ITB) pump and catheter systems more effectively and with fewer complications. The authors present the techniques for optimal pump and catheter implantation, including subfascial pump placement; insertion of the Tuohy needle in an oblique, paramedian trajectory; and positioning of the catheter tip at levels commensurate with the therapeutic indication: approximately T10-12 for spastic diplegia, C5-T2 for spastic tetraparesis, and C1-4 for generalized secondary dystonia. Techniques to minimize the incidence of cerebrospinal fluid leakage are described, including the identification of preoperative occult hydrocephalus and the use of a suture ligature around the Tuohy needle at its exit site from the fascia. Techniques to minimize surgery-related infection are also detailed; most involve the use of iodine solutions multiple times intraoperatively. Techniques to insert intrathecal catheters during spinal fusion are addressed, particularly the technique of inserting the catheter cephalad to the fusion site. Panel members advocate the aforementioned techniques to improve the efficacy of and decrease the morbidity associated with ITB therapy.


Subject(s)
Baclofen/administration & dosage , Catheters, Indwelling/standards , Cerebral Palsy/drug therapy , Dystonia/drug therapy , GABA Agonists/administration & dosage , Infusion Pumps, Implantable/standards , Injections, Spinal/standards , Muscle Relaxants, Central/standards , Quadriplegia/drug therapy , Quality Assurance, Health Care/standards , Child , Equipment Design , Humans , Muscle Spasticity/drug therapy , Postoperative Complications/drug therapy , Spinal Fusion
5.
Rev. colomb. anestesiol ; 24(3): 265-8, jul.-sept. 1996. tab
Article in Spanish | LILACS | ID: lil-218079

ABSTRACT

En el presente artículo se hace una revisión de la técnica de dosificación de los relajantes musculares por medio de los estimuladores de nervios periféricos; de las características de la estimulación; de la manera como se efectúa la reversión del bloqueo neuromuscular y algunas indicaciones importantes de la técnica. También se describe la utilización de la contracción única (Single twitch) ó "SI"; de la serie de cuatro (Train of four) ó "S4"; de la serie de dos (Double burst) ó "S2" del estímulo tetánico; y de algunas pautas para aprovechar al máximo esta ayuda diagnóstica


Subject(s)
Humans , Monitoring, Physiologic , Muscle Relaxants, Central , Muscle Relaxants, Central/adverse effects , Muscle Relaxants, Central/standards