Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 16.826
Filter
1.
Mikrochim Acta ; 191(6): 309, 2024 05 07.
Article in English | MEDLINE | ID: mdl-38714599

ABSTRACT

Copper-doped carbon dots and aminated carbon nanotubes (Cu-CDs/NH2-CNTs) nanocomposites were synthesized by a one-step growth method, and the composites were characterized for their performance. An electrochemical sensor for sensitive detection of bisphenol A (BPA) was developed for using Cu-CDs/NH2-CNTs nanocomposites modified with glassy carbon electrodes (GCE). The sensor exhibited an excellent electrochemical response to BPA in 0.2 M PBS (pH 7.0) under optimally selected conditions. The linear range of the sensor for BPA detection was 0.5-160 µM, and the detection limit (S/N = 3) was 0.13 µM. Moreover, the sensor has good interference immunity, stability and reproducibility. In addition, the feasibility of the practical application of the sensor was demonstrated by the detection of BPA in bottled drinking water and Liu Yang River water.


Subject(s)
Benzhydryl Compounds , Copper , Electrochemical Techniques , Electrodes , Limit of Detection , Nanotubes, Carbon , Phenols , Water Pollutants, Chemical , Benzhydryl Compounds/analysis , Phenols/analysis , Phenols/chemistry , Nanotubes, Carbon/chemistry , Copper/chemistry , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Water Pollutants, Chemical/analysis , Drinking Water/analysis , Quantum Dots/chemistry , Carbon/chemistry , Rivers/chemistry
2.
Sci Rep ; 14(1): 10117, 2024 05 02.
Article in English | MEDLINE | ID: mdl-38698033

ABSTRACT

In this research, the hydrophilic structure of multi-walled carbon nanotubes (MWCNTs) was modified by synthesizing polycitric acid (PCA) and attaching folic acid (FA) to create MWCNT-PCA-FA. This modified nanocomplex was utilized as a carrier for the lipophilic compound curcumin (Cur). Characterization techniques including TGA, TEM, and UV-visible spectrophotometry were used to analyze the nanocomplex. The mechanism of cancer cell death induced by MWCNT-PCA-FA was studied extensively using the MTT assay, colony formation analysis, cell cycle assessment via flow cytometry, and apoptosis studies. Furthermore, we assessed the antitumor efficacy of these targeted nanocomplexes following exposure to laser radiation. The results showed that the nanocomposites and free Cur had significant toxicity on melanoma cancer cells (B16F10 cells) while having minimal impact on normal cells (NHDF cells). This selectivity for cancerous cells demonstrates the potential of these compounds as therapeutic agents. Furthermore, MWCNT-PCA-FA/Cur showed superior cytotoxicity compared to free Cur alone. Colony formation studies confirmed these results. The researchers found that MWCNT-FA-PCA/Cur effectively induced programmed cell death. In photothermal analysis, MWCNT-PCA-FA/Cur combined with laser treatment achieved the highest mortality rate. These promising results suggest that this multifunctional therapeutic nanoplatform holds the potential for combination cancer therapies that utilize various established therapeutic methods.


Subject(s)
Curcumin , Nanotubes, Carbon , Curcumin/pharmacology , Curcumin/chemistry , Nanotubes, Carbon/chemistry , Cell Line, Tumor , Humans , Mice , Animals , Folic Acid/chemistry , Apoptosis/drug effects , Melanoma/drug therapy , Melanoma/pathology , Melanoma/therapy , Photothermal Therapy/methods , Antineoplastic Agents/pharmacology , Antineoplastic Agents/chemistry , Drug Carriers/chemistry , Cell Survival/drug effects
3.
PLoS One ; 19(5): e0303359, 2024.
Article in English | MEDLINE | ID: mdl-38728321

ABSTRACT

As-produced carbon nanotubes contain impurities which can dominate the properties of the material and are thus undesired. Herein we present a multi-step purification treatment that combines the use of steam and hydrochloric acid in an iterative manner. This allows the reduction of the iron content down to 0.2 wt. % in samples of single-walled carbon nanotubes (SWCNTs). Remarkably, Raman spectroscopy analysis reveals that this purification strategy does not introduce structural defects into the SWCNTs' backbone. To complete the study, we also report on a simplified approach for the quantitative assessment of iron using UV-Vis spectroscopy. The amount of metal in SWCNTs is assessed by dissolving in HCl the residue obtained after the complete combustion of the sample. This leads to the creation of hexaaquairon(III) chloride which allows the determination of the amount of iron, from the catalyst, by UV-Vis spectroscopy. The main advantage of the proposed strategy is that it does not require the use of additional complexing agents.


Subject(s)
Hydrochloric Acid , Iron , Nanotubes, Carbon , Spectrophotometry, Ultraviolet , Spectrum Analysis, Raman , Steam , Nanotubes, Carbon/chemistry , Iron/analysis , Iron/chemistry , Hydrochloric Acid/chemistry , Spectrum Analysis, Raman/methods
4.
J Nanobiotechnology ; 22(1): 239, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38735951

ABSTRACT

Widespread distribution of porcine epidemic diarrhea virus (PEDV) has led to catastrophic losses to the global pig farming industry. As a result, there is an urgent need for rapid, sensitive and accurate tests for PEDV to enable timely and effective interventions. In the present study, we develop and validate a floating gate carbon nanotubes field-effect transistor (FG CNT-FET)-based portable immunosensor for rapid identification of PEDV in a sensitive and accurate manner. To improve the affinity, a unique PEDV spike protein-specific monoclonal antibody is prepared by purification, and subsequently modified on FG CNT-FET sensor to recognize PEDV. The developed FET biosensor enables highly sensitive detection (LoD: 8.1 fg/mL and 100.14 TCID50/mL for recombinant spike proteins and PEDV, respectively), as well as satisfactory specificity. Notably, an integrated portable platform consisting of a pluggable FG CNT-FET chip and a portable device can discriminate PEDV positive from negative samples and even identify PEDV and porcine deltacoronavirus within 1 min with 100% accuracy. The portable sensing platform offers the capability to quickly, sensitively and accurately identify PEDV, which further points to a possibility of point of care (POC) applications of large-scale surveillance in pig breeding facilities.


Subject(s)
Biosensing Techniques , Nanotubes, Carbon , Porcine epidemic diarrhea virus , Porcine epidemic diarrhea virus/isolation & purification , Animals , Swine , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Nanotubes, Carbon/chemistry , Limit of Detection , Immunoassay/methods , Immunoassay/instrumentation , Antibodies, Monoclonal/immunology , Transistors, Electronic , Swine Diseases/diagnosis , Swine Diseases/virology , Spike Glycoprotein, Coronavirus/immunology , Spike Glycoprotein, Coronavirus/analysis , Coronavirus Infections/diagnosis , Coronavirus Infections/veterinary , Coronavirus Infections/virology , Antibodies, Viral/immunology , Equipment Design
5.
ACS Appl Mater Interfaces ; 16(19): 25404-25414, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38692284

ABSTRACT

Liquid crystal elastomers (LCEs), as a classical two-way shape-memory material, are good candidates for developing artificial muscles that mimic the contraction, expansion, or rotational behavior of natural muscles. However, biomimicry is currently focused more on the actuation functions of natural muscles dominated by muscle fibers, whereas the tactile sensing functions that are dominated by neuronal receptors and synapses have not been well captured. Very few studies have reported the sensing concept for LCEs, but the signals were still donated by macroscopic actuation, that is, variations in angle or length. Herein, we develop a conductive porous LCE (CPLCE) using a solvent (dimethyl sulfoxide (DMSO))-templated photo-cross-linking strategy, followed by carbon nanotube (CNT) incorporation. The CPLCE has excellent reversible contraction/elongation behavior in a manner similar to the actuation functions of skeletal muscles. Moreover, the CPLCE shows excellent pressure-sensing performance by providing real-time electrical signals and is capable of microtouch sensing, which is very similar to natural tactile sensing. Furthermore, macroscopic actuation and tactile sensation can be integrated into a single system. Proof-of-concept studies reveal that the CPLCE-based artificial muscle is sensitive to external touch while maintaining its excellent actuation performance. The CPLCE with tactile sensation beyond reversible actuation is expected to benefit the development of versatile artificial muscles and intelligent robots.


Subject(s)
Elastomers , Liquid Crystals , Nanotubes, Carbon , Liquid Crystals/chemistry , Elastomers/chemistry , Nanotubes, Carbon/chemistry , Porosity , Solvents/chemistry , Touch/physiology , Artificial Organs , Muscle, Skeletal/physiology , Muscle, Skeletal/chemistry , Humans
6.
Int J Mol Sci ; 25(9)2024 May 04.
Article in English | MEDLINE | ID: mdl-38732243

ABSTRACT

This study presents the functionalization of silk fabric with SWCNT ink. The first step was the formation of a polydopamine (PDA) thin coating on the silk fabric to allow for effective bonding of SWCNTs. PDA formation was carried out directly on the fabric by means of polymerization of dopamine in alkali conditions. The Silk/PDA fabric was functionalized with SWCNT ink of different SWCNT concentrations by using the dip-coating method. IR and Raman analyses show that the dominant ß-sheet structure of silk fibroin after the functionalization process remains unchanged. The heat resistance is even slightly improved. The hydrophobic silk fabric becomes hydrophilic after functionalization due to the influence of PDA and the surfactant in SWCNT ink. The ink significantly changes the electrical properties of the silk fabric, from insulating to conductive. The volume resistance changes by nine orders of magnitude, from 2.4 × 1012 Ω to 2.3 × 103 Ω for 0.12 wt.% of SWCNTs. The surface resistance changes by seven orders of magnitude, from 2.1 × 1012 Ω to 2.4 × 105 Ω for 0.17 wt.% of SWCNTs. The volume and surface resistance thresholds are determined to be about 0.05 wt.% and 0.06 wt.%, respectively. The low value of the percolation threshold indicates efficient functionalization, with high-quality ink facilitating the formation of percolation paths through SWCNTs and the influence of the PDA linker.


Subject(s)
Electric Conductivity , Indoles , Ink , Nanotubes, Carbon , Polymers , Silk , Indoles/chemistry , Polymers/chemistry , Silk/chemistry , Nanotubes, Carbon/chemistry , Textiles , Hydrophobic and Hydrophilic Interactions
7.
Sci Rep ; 14(1): 10826, 2024 05 11.
Article in English | MEDLINE | ID: mdl-38734799

ABSTRACT

Sequencing the DNA nucleobases is essential in the diagnosis and treatment of many diseases related to human genes. In this article, the encapsulation of DNA nucleobases with some of the important synthesized chiral (7, 6), (8, 6), and (10, 8) carbon nanotubes were investigated. The structures were modeled by applying density functional theory based on tight binding method (DFTB) by considering semi-empirical basis sets. Encapsulating DNA nucleobases on the inside of CNTs caused changes in the electronic properties of the selected chiral CNTs. The results confirmed that van der Waals (vdW) interactions, π-orbitals interactions, non-bonded electron pairs, and the presence of high electronegative atoms are the key factors for these changes. The result of electronic parameters showed that among the CNTs, CNT (8, 6) is a suitable choice in sequencing guanine (G) and cytosine (C) DNA nucleobases. However, they are not able to sequence adenine (A) and thymine (T). According to the band gap energy engineering approach and absorption energy, the presence of G and C DNA nucleobases decreased the band gap energy of CNTs. Hence selected CNTs suggested as biosensor substrates for sequencing G and C DNA nucleobases.


Subject(s)
DNA , Guanine , Nanotubes, Carbon , Nanotubes, Carbon/chemistry , DNA/chemistry , Guanine/chemistry , Density Functional Theory , Adenine/chemistry , Cytosine/chemistry , Thymine/chemistry , Sequence Analysis, DNA/methods , Electrons , Models, Molecular , Humans
8.
Biosens Bioelectron ; 258: 116350, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38705075

ABSTRACT

Early monitoring of cardiovascular disease (CVD) is crucial for its treatment and prognosis. Hence, highly specific and sensitive detection method is urgently needed. In this study, we propose a novel herringbone microfluid chip with aptamer functionalized core-shell photonic crystal (PhC) barcode integration for high throughput multiplex CVD detection. Based on the PhC derived from co-assembled carboxylated single-wall carbon nanotubes and silicon dioxide nanoparticles, we obtain core-shell PhC barcodes by hydrogel replicating and partially etching. These core-shell PhC barcodes not only retain the original structural colors coding element, but also fully expose a large number of carboxyl elements in the ore for the probe immobilization. We further combine the functionalized barcodes with herringbone groove microfluidic chip to elucidate its acceptability in testing clinical sample. It is demonstrated that the special design of microfluidic chip can significantly enhance fluid vortex resistance and contact frequency, improving the sample capture efficiency and detection sensitivity. These features indicate that our core-shell PhC barcodes-integrated herringbone microfluidic system possesses great potential for multiplex biomarker detection in clinical application.


Subject(s)
Biomarkers , Biosensing Techniques , Lab-On-A-Chip Devices , Nanotubes, Carbon , Nanotubes, Carbon/chemistry , Humans , Biosensing Techniques/instrumentation , Equipment Design , Aptamers, Nucleotide/chemistry , Silicon Dioxide/chemistry , Photons , Nanoparticles/chemistry , Microfluidic Analytical Techniques/instrumentation
9.
Biosens Bioelectron ; 258: 116358, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38718634

ABSTRACT

Wearable sensors for sweat glucose monitoring are gaining massive interest as a patient-friendly and non-invasive way to manage diabetes. The present work offers an alternative on-body method employing an all-printed flexible electrochemical sensor to quantify the amount of glucose in human sweat. The working electrode of the glucose sensor was printed using a custom-formulated ink containing multi-walled carbon nanotube (MWCNT), poly (3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOPT: PSS), and iron (II, III) oxide (Fe3O4) nanoparticles. This novel ink composition has good conductivity, enhanced catalytic activity, and excellent selectivity. The working electrode was modified using Prussian blue (PB) nanoparticles and glucose oxidase enzyme (GOx). The sensor displayed a linear chronoamperometric response to glucose from 1 µM to 400 µM, with a precise detection limit of ∼0.38 µM and an impressive sensitivity of ∼4.495 µAµM-1cm-2. The sensor stored at 4 °C exhibited excellent stability over 60 days, high selectivity, and greater reproducibility. The glucose detection via the standard addition method in human sweat samples acquired a high recovery rate of 96.0-98.6%. Examining human sweat during physical activity also attested to the biosensor's real-time viability. The results also show an impressive correlation between glucose levels obtained from a commercial blood glucose meter and sweat glucose concentrations. Remarkably, the present results outperform previously published printed glucose sensors in terms of detection range, low cost, ease of manufacturing, stability, selectivity, and wearability.


Subject(s)
Biosensing Techniques , Glucose Oxidase , Glucose , Limit of Detection , Nanocomposites , Nanotubes, Carbon , Sweat , Wearable Electronic Devices , Humans , Biosensing Techniques/instrumentation , Nanotubes, Carbon/chemistry , Sweat/chemistry , Nanocomposites/chemistry , Glucose/analysis , Glucose Oxidase/chemistry , Ink , Electrochemical Techniques , Ferric Compounds/chemistry , Ferrocyanides/chemistry , Polymers/chemistry , Reproducibility of Results , Bridged Bicyclo Compounds, Heterocyclic/chemistry , Polystyrenes
10.
ACS Appl Mater Interfaces ; 16(20): 25601-25609, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38727578

ABSTRACT

We report an ultrasensitive sandwich-type electrochemical immunosensor to detect the breast cancer biomarker CA 15-3. Amine-functionalized composite of reduced graphene oxide and Fe3O4 nanoparticles (MRGO-NH2) was used as an electrochemical sensing platform material to modify the electrodes. The nanocomposite comprising Pt and Fe3O4 nanoparticles (NPs) anchored on multiwalled carbon nanotubes (Pt-Fe3O4-MWCNTs-NH2) was utilized as a pseudoenzymatic signal-amplifying label. Compared to reduced graphene oxide, the composite MRGO-NH2 platform material demonstrated a higher electrochemical signal. In the Pt-Fe3O4-MWCNTs-NH2 label, multiwalled carbon nanotubes provided the substratum to anchor abundant catalytic Pt and Fe3O4 NPs. The nanocomposites were thoroughly characterized using transmission electron microscopy, Fourier transform infrared spectroscopy, X-ray diffraction, scanning electron microscopy, and X-ray photoelectron spectroscopy. An electroanalytical study and prevalidation of the immunosensor was carried out. The immunosensor exhibited exceptional capabilities in detecting CA 15-3, offering a wider linear range of 0.0005-100 U mL-1 and a lower detection limit of 0.00008 U mL-1. Moreover, the designed immunosensor showed good specificity, reproducibility, and acceptable stability. The sensor was successfully applied to analyze samples from breast cancer patients, yielding reliable results.


Subject(s)
Biomarkers, Tumor , Breast Neoplasms , Electrochemical Techniques , Nanocomposites , Nanotubes, Carbon , Platinum , Humans , Nanotubes, Carbon/chemistry , Breast Neoplasms/diagnosis , Nanocomposites/chemistry , Electrochemical Techniques/methods , Biomarkers, Tumor/analysis , Biomarkers, Tumor/blood , Female , Platinum/chemistry , Biosensing Techniques/methods , Graphite/chemistry , Amines/chemistry , Mucin-1/analysis , Mucin-1/blood , Immunoassay/methods , Limit of Detection
11.
ACS Nano ; 18(20): 13214-13225, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38717114

ABSTRACT

Facing the escalating threat of viruses worldwide, the development of efficient sensor elements for rapid virus detection has never been more critical. Traditional point-of-care (POC) sensors struggle due to their reliance on fragile biological receptors and limited adaptability to viral strains. In this study, we introduce a nanosensor design for receptor-free virus recognitions using near-infrared (NIR) fluorescent single-walled carbon nanotubes (SWCNTs) functionalized with a poly(ethylene glycol) (PEG)-phospholipid (PEG-lipid) array. Three-dimensional (3D) corona interfaces of the nanosensor array enable selective and sensitive detection of diverse viruses, including Ebola, Lassa, H3N2, H1N1, Middle East respiratory syndrome (MERS), severe acute respiratory syndrome coronavirus 1 (SARS-CoV-1), and SARS-CoV-2, even without any biological receptors. The PEG-lipid components, designed considering chain length, fatty acid saturation, molecular weight, and end-group moieties, allow for precise quantification of viral recognition abilities. High-throughput automated screening of the array demonstrates how the physicochemical properties of the PEG-lipid/SWCNT 3D corona interfaces correlate with viral detection efficiency. Utilizing molecular dynamics and AutoDock simulations, we investigated the impact of PEG-lipid components on 3D corona interface formation, such as surface coverage and hydrodynamic radius and specific molecular interactions based on chemical potentials. Our findings not only enhance detection specificity across various antigens but also accelerate the development of sensor materials for promptly identifying and responding to emerging antigen threats.


Subject(s)
Nanotubes, Carbon , Polyethylene Glycols , SARS-CoV-2 , Nanotubes, Carbon/chemistry , Polyethylene Glycols/chemistry , SARS-CoV-2/isolation & purification , Humans , COVID-19/virology , Phospholipids/chemistry , Biosensing Techniques/methods , Viruses/chemistry , Polymers/chemistry
12.
Chemosphere ; 358: 142277, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38719118

ABSTRACT

Peracetic acid (PAA) has garnered significant attention as a novel disinfectant owing to its remarkable oxidative capacity and minimal potential to generate byproducts. In this study, we prepared a novel catalyst, denoted as cobalt modified nitrogen-doped carbon nanotubes (Co@N-CNTs), and evaluated it for PAA activation. Modification with cobalt nanoparticles (∼4.8 nm) changed the morphology and structure of the carbon nanotubes, and greatly improved their ability to activate PAA. Co@N-CNTs/PAA catalytic system shows outstanding catalytic degradation ability of antiviral drugs. Under neutral conditions, with a dosage of 0.05 g/L Co@N-CNT-9.8 and 0.25 mM PAA, the removal efficiency of acyclovir (ACV) reached 98.3% within a mere 10 min. The primary reactive species responsible for effective pollutant degradation were identified as acetylperoxyl radicals (CH3C(O)OO•) and acetyloxyl radicals (CH3C(O)O•). In addition, density functional theory (DFT) proved that Co nanoparticles, as the main catalytic sites, were more likely to adsorb PAA and transfer more electrons than N-doped graphene. This study explored the feasibility of PAA degradation of antiviral drugs in sewage, and provided new insights for the application of heterogeneous catalytic PAA in environmental remediation.


Subject(s)
Antiviral Agents , Cobalt , Nanotubes, Carbon , Nitrogen , Peracetic Acid , Nanotubes, Carbon/chemistry , Nitrogen/chemistry , Cobalt/chemistry , Peracetic Acid/chemistry , Catalysis , Antiviral Agents/chemistry , Water Pollutants, Chemical/chemistry , Acyclovir/chemistry , Adsorption
13.
Langmuir ; 40(20): 10634-10647, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38723623

ABSTRACT

Hematin, an iron-containing porphyrin compound, plays a crucial role in various biological processes, including oxygen transport, storage, and functionality of the malarial parasite. Specifically, hematin-Fe interacts with the nitrogen atom of antimalarial drugs, forming an intermediate step crucial for their function. The electron transfer functionality of hematin in biological systems has been scarcely investigated. In this study, we developed a biomimicking electrical wiring of hematin-Fe with a model N-drug system, represented as {hematin-Fe---N-drug}. We achieved this by immobilizing hematin on a multiwalled carbon nanotube (MWCNT)/N-graphene quantum dot (N-GQD) modified electrode (MWCNT/N-GQD@Hemat). N-GQD serves as a model molecular drug system containing nitrogen atoms to mimic the {hematin-Fe---N-drug} interaction. The prepared bioelectrode exhibited a distinct redox peak at a measured potential (E1/2) of -0.410 V vs Ag/AgCl, accompanied by a surface excess value of 3.54 × 10-9 mol cm-2. This observation contrasts significantly with the weak or electroinactive electrochemical responses documented in literature-based hematin systems. We performed a comprehensive set of physicochemical and electrochemical characterizations on the MWCNT/N-GQD@Hemat system, employing techniques including FESEM, TEM, Raman spectroscopy, IR spectroscopy, and AFM. To evaluate the biomimetic electrode's electroactivity, we investigated the selective-mediated reduction of H2O2 as a model system. As an important aspect of our research, we demonstrated the use of scanning electrochemical microscopy to visualize the in situ electron transfer reaction of the biomimicking electrode. In an independent study, we showed enzyme-less electrocatalytic reduction and selective electrocatalytic sensing of H2O2 with a detection limit of 319 nM. We achieved this using a batch injection analysis-coupled disposable screen-printed electrode system in physiological solution.


Subject(s)
Hemin , Hydrogen Peroxide , Nanotubes, Carbon , Oxidation-Reduction , Hydrogen Peroxide/chemistry , Hemin/chemistry , Nanotubes, Carbon/chemistry , Electrodes , Graphite/chemistry , Quantum Dots/chemistry , Nitrogen/chemistry , Surface Properties , Electrochemical Techniques/methods , Catalysis
14.
J Chem Inf Model ; 64(10): 3992-4001, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38739914

ABSTRACT

Owing to the value of DNA-wrapped single-walled carbon nanotube (SWNT)-based sensors for chemically specific imaging in biology, we explore machine learning (ML) predictions DNA-SWNT serotonin sensor responsivity as a function of DNA sequence based on the whole SWNT fluorescence spectra. Our analysis reveals the crucial role of DNA sequence in the binding modes of DNA-SWNTs to serotonin, with a smaller influence of SWNT chirality. Regression ML models trained on existing data sets predict the change in the fluorescence emission in response to serotonin, ΔF/F, at over a hundred wavelengths for new DNA-SWNT conjugates, successfully identifying some high- and low-response DNA sequences. Despite successful predictions, we also show that the finite size of the training data set leads to limitations on prediction accuracy. Nevertheless, incorporating entire spectra into ML models enhances prediction robustness and facilitates the discovery of novel DNA-SWNT sensors. Our approaches show promise for identifying new chemical systems with specific sensing response characteristics, marking a valuable advancement in DNA-based system discovery.


Subject(s)
DNA , Machine Learning , Nanotubes, Carbon , Serotonin , Nanotubes, Carbon/chemistry , DNA/chemistry , Spectrometry, Fluorescence , Biosensing Techniques/methods , Base Sequence
15.
Environ Sci Pollut Res Int ; 31(24): 35651-35665, 2024 May.
Article in English | MEDLINE | ID: mdl-38740683

ABSTRACT

In the present study, two iron phthalocyanine (FePc)-based nanocatalysts were synthesized and fully characterized. The carbon nanotubes (CNT) functionalized in an easy way with either Fe(II)Pc or Fe(III)Pc exhibit a very good catalytical activity. The activity in real wastewater effluent was comparable with the activity in distilled water. The procedure of modeling and optimizing with the assistance of chemometrics, utilizing design of experiments (DOE) and response surface methodology (RSM), revealed the conditions of optimum for decaying Reactive Yellow 84 on the nanocatalysts FePc_CNT. These optimal conditions included a catalyst dose of 1.70 g/L and an initial concentration (C0) of 20.0 mg/L. Under the indicated optimal conditions, the experimental findings verified that the removal efficiency was equal to Y = 98.92%, representing the highest observed value in this study. Under UVA light, after only 15 min of reaction, over 94% of dye was removed using both catalysts. The reuse experiments show that the activity of both nanohybrid material based on FePc-CNT slightly decreases over four consecutive runs. The quenching experiments show that RY84 was removed through radical pathways (O2•- and •OH) as well as non-radical pathways (1O2 and direct electron transfer).


Subject(s)
Indoles , Nanotubes, Carbon , Water Pollutants, Chemical , Nanotubes, Carbon/chemistry , Catalysis , Indoles/chemistry , Water Pollutants, Chemical/chemistry , Iron/chemistry , Isoindoles , Wastewater/chemistry , Ferrous Compounds
16.
ACS Appl Mater Interfaces ; 16(21): 27102-27113, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38745465

ABSTRACT

Interleukin-6 (IL-6) is known to play a critical role in the progression of inflammatory diseases such as cardiovascular disease, cancer, sepsis, viral infection, neurological disease, and autoimmune diseases. Emerging diagnostic and prognostic tools, such as optical nanosensors, experience challenges in translation to the clinic in part due to protein corona formation, dampening their selectivity and sensitivity. To address this problem, we explored the rational screening of several classes of biomolecules to be employed as agents in noncovalent surface passivation as a strategy to screen interference from nonspecific proteins. Findings from this screening were applied to the detection of IL-6 by a fluorescent-antibody-conjugated single-walled carbon nanotube (SWCNT)-based nanosensor. The IL-6 nanosensor exhibited highly sensitive and specific detection after passivation with a polymer, poly-l-lysine, as demonstrated by IL-6 detection in human serum within a clinically relevant range of 25 to 25,000 pg/mL, exhibiting a limit of detection over 3 orders of magnitude lower than prior antibody-conjugated SWCNT sensors. This work holds potential for the rapid and highly sensitive detection of IL-6 in clinical settings with future application to other cytokines or disease-specific biomarkers.


Subject(s)
Biosensing Techniques , Interleukin-6 , Nanotubes, Carbon , Interleukin-6/blood , Interleukin-6/analysis , Humans , Nanotubes, Carbon/chemistry , Biosensing Techniques/methods , Limit of Detection , Polylysine/chemistry
17.
Int J Biol Macromol ; 269(Pt 1): 131962, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38692550

ABSTRACT

Carbon nanotubes are promising materials for biomedical applications like delivery systems and tissue scaffolds. In this paper, magnetic carbon nanotubes (M-CNTs) covered with bovine serum albumin (M-CNTs-BSA) or functionalized with hydrophilic monomers (M-CNTs-HL) were synthesized, characterized, and evaluated concerning their interaction with Caco-2 cells. There is no comparison between these two types of functionalization, and this study aimed to verify their influence on the material's interaction with the cells. Different concentrations of the nanotubes were applied to investigate cytotoxicity, cell metabolism, oxidative stress, apoptosis, and capability to cross biomimetic barriers. The materials showed cytocompatibility up to 100 µg mL-1 and a hemolysis rate below 2 %. Nanotubes' suspensions were allowed to permeate Caco-2 monolayers for up to 8 h under the effect of the magnetic field. Magnetic nanoparticles associated with the nanotubes allowed estimation of permeation through the monolayers, with values ranging from 0.50 to 7.19 and 0.27 to 9.30 × 10-3 µg (equivalent to 0.43 to 6.22 and 0.23 to 9.54 × 10-2 % of the initially estimated mass of magnetic nanoparticles) for cells exposed and non-exposed to the magnets, respectively. Together, these results support that the developed materials are promising for applications in biomedical and biotechnological fields.


Subject(s)
Hydrophobic and Hydrophilic Interactions , Nanotubes, Carbon , Serum Albumin, Bovine , Nanotubes, Carbon/chemistry , Humans , Caco-2 Cells , Serum Albumin, Bovine/chemistry , Permeability , Animals , Hemolysis/drug effects , Cell Survival/drug effects , Magnetite Nanoparticles/chemistry , Magnetite Nanoparticles/toxicity , Oxidative Stress/drug effects , Apoptosis/drug effects , Materials Testing , Cattle
18.
Sci Rep ; 14(1): 12073, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38802442

ABSTRACT

Carbon nanotubes (CNTs) have the potential to serve as delivery systems for medicinal substances and gene treatments, particularly in cancer treatment. Co-delivery of curcumin (CUR) and Methotrexate (MTX) has shown promise in cancer treatment, as it uses fewer drugs and has fewer side effects. This study used MTX-conjugated albumin (BSA)-based nanoparticles (BSA-MTX) to enhance and assess the efficiency of CUR. In-vitro cytotoxicity tests, DLS, TEM, FTIR, UV/Vis, SEM, and DSC studies assessed the formulations' physical and chemical properties. The Proteinase K enzyme was used to severe amidic linkages between MTX and BSA. The findings demonstrated the efficacy of using ƒ-MWCNT-CUR-BSA-MTX as a vehicle for efficient co-delivery of CUR and MTX in cancer treatment. The MTT colorimetric method was used to evaluate the effect of chemical and medicinal compounds. Cell division was studied using the MTT method to investigate the effect of pure MWCNT, pure CUR, MTX-BSA, and ƒ-MWCNT-CUR-MTX-BSA. Studies on cell lines have shown that the combination of curcumin and MTX with CNT can increase and improve the effectiveness of both drugs against cancer. A combination of drugs curcumin and methotrexate simultaneously had a synergistic effect on MCF-7 cells, which indicated that these drugs could potentially be used as a strategy for both prevention and treatment of breast cancer. Also, ƒ-MWCNT-CUR-MTX-BSA was found to have a significant effect on cancer treatment with minimal toxicity compared to pure curcumin, pure MTX-BSA, MTX, and ƒ-MWCNT alone. Unique properties such as a high ratio of specific surface area to volume, high chemical stability, chemical adsorption ability, high capacity of drug and biomolecules of carbon nanotubes, as well as multiple drug loading at the same time The combination of ƒ-MWCNT-CUR-BSA MTX significantly impacts cancer therapy), are desirable as an alternative option for targeted drug delivery and high therapeutic efficiency.


Subject(s)
Curcumin , Methotrexate , Nanotubes, Carbon , Nanotubes, Carbon/chemistry , Methotrexate/chemistry , Methotrexate/pharmacology , Methotrexate/administration & dosage , Humans , Curcumin/pharmacology , Curcumin/chemistry , Curcumin/administration & dosage , Nanoparticles/chemistry , Drug Delivery Systems , Serum Albumin, Bovine/chemistry , Antineoplastic Agents/pharmacology , Antineoplastic Agents/chemistry , Antineoplastic Agents/administration & dosage , MCF-7 Cells , Drug Carriers/chemistry , Cell Survival/drug effects , Cell Line, Tumor
19.
Mikrochim Acta ; 191(6): 344, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38802523

ABSTRACT

A molecularly imprinted electrochemiluminescent sensor is developed for the sensitive detection of tetracycline in environmental and food samples. The sensor uses an ionic liquid (i.e. [APMIM]Br) modified graphene-carbon nanotube composite (GMI) material as substrate, a double-layered core-shell metal-organic framework NH2-UiO-66@ZIF-8 (NUZ) loaded bipyridyl ruthenium (NUZ@Ru) as luminescent material, and a molecularly imprinted copolymer of o-phenylenediamine and hydroquinone as recognition element. The ionic liquid-modified graphene-carbon nanotube composite has a favorable three-dimensional structure, high specific surface area, and good hydrophilicity; the core-shell structured metal-organic framework has high stability and plentiful reaction sites for loading; the molecularly imprinted copolymer film has enhanced stability and recognition effect. Hence, the resulting sensor combines the merits of several materials and presents improved performance. Under the optimum detection conditions, it shows a wide linear range of 0.05 µM - 1 mM, a low detection limit of 20 nM, high selectivity, and excellent stability. It has been successfully applied to the detection of tetracycline in different samples.


Subject(s)
Electrochemical Techniques , Limit of Detection , Luminescent Measurements , Metal-Organic Frameworks , Molecularly Imprinted Polymers , Tetracycline , Tetracycline/analysis , Tetracycline/chemistry , Molecularly Imprinted Polymers/chemistry , Metal-Organic Frameworks/chemistry , Luminescent Measurements/methods , Electrochemical Techniques/methods , Graphite/chemistry , Nanotubes, Carbon/chemistry , Food Contamination/analysis , Ionic Liquids/chemistry , Anti-Bacterial Agents/analysis , Anti-Bacterial Agents/chemistry , Water Pollutants, Chemical/analysis , Molecular Imprinting
20.
Mikrochim Acta ; 191(5): 247, 2024 04 08.
Article in English | MEDLINE | ID: mdl-38587580

ABSTRACT

Alumina inorganic molecularly imprinted polymer (MIP) modified multi-walled carbon nanotubes (MWCNTs) on a glassy carbon electrode (MWCNTs-Al2O3-MIP/GCE) was firstly designed and fabricated by one-step electro deposition technique for the detection of uric acid (UA) in sweat. The UA templates were embedded within the inorganic MIP by co-deposition with Al2O3. Through the evaluation of morphology and structure by Field Emission Scanning Electron Microscope (SEM), Energy Dispersive X-ray Spectroscopy (EDS), X-ray Photoelectron Spectroscopy (XPS) and Transmission Electron Microscopy (TEM), it was verified that the specific recognition sites can be fabricated in the electrodeposited Al2O3 molecular imprinted layer. Due to the high selectivity of molecular imprinting holes, the MWCNTs-Al2O3-MIP/GCE electrode demonstrated an impressive imprinting factor of approximately 2.338 compared to the non-molecularly imprinted glassy carbon electrode (MWCNTs-Al2O3-NIP/GCE) toward uric acid detection. Moreover, it exhibited a remarkable limit of detection (LOD) of 50 nM for UA with wide detection range from 50 nM to 600 µM. The MWCNTs-Al2O3-MIP/GCE electrode also showed strong interference resistance against common substances found in sweat. These results highlight the excellent interference resistance and selectivity of MWCNTs-Al2O3-MIP/GCE sensor, positioning it as a novel sensing platform for non-invasive uric acid detection in human sweat.


Subject(s)
Nanotubes, Carbon , Phosphates , Sweat , Humans , Molecularly Imprinted Polymers , Uric Acid , Aluminum Oxide
SELECTION OF CITATIONS
SEARCH DETAIL
...