Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Am J Obstet Gynecol ; 223(6): 907.e1-907.e13, 2020 12.
Article in English | MEDLINE | ID: mdl-32497609

ABSTRACT

BACKGROUND: It is crucial to interpret fetal heart rate patterns with a focus on the pattern evolution during labor to estimate the relationship between cerebral palsy and delivery. However, nationwide data are not available. OBJECTIVE: The aim of our study was to demonstrate the features of fetal heart rate pattern evolution and estimate the timing of fetal brain injury during labor in cerebral palsy cases. STUDY DESIGN: In this longitudinal study, 1069 consecutive intrapartum fetal heart rate strips from infants with severe cerebral palsy at or beyond 34 weeks of gestation, were analyzed. They were categorized as follows: (1) continuous bradycardia (Bradycardia), (2) persistently nonreassuring, (3) reassuring-prolonged deceleration, (4) Hon's pattern, and (5) persistently reassuring. The clinical factors underlying cerebral palsy in each group were assessed. RESULTS: Hypoxic brain injury during labor (those in the reassuring-prolonged deceleration and Hon's pattern groups) accounted for 31.5% of severe cerebral palsy cases and at least 30% of those developed during the antenatal period. Of the 1069 cases, 7.86% were classified as continuous bradycardia (n=84), 21.7% as persistently nonreassuring (n=232), 15.6% as reassuring-prolonged deceleration (n=167), 15.9% as Hon's pattern (n=170), 19.8% as persistently reassuring (n=212), and 19.1% were unclassified (n=204). The overall interobserver agreement was moderate (kappa 0.59). Placental abruption was the most common cause (31.9%) of cerebral palsy, accounting for almost 90% of cases in the continuous bradycardia group (64 of 73). Among the cases in the Hon's pattern group (n=67), umbilical cord abnormalities were the most common clinical factor for cerebral palsy development (29.9%), followed by placental abruption (20.9%), and inappropriate operative vaginal delivery (13.4%). CONCLUSION: Intrapartum hypoxic brain injury accounted for approximately 30% of severe cerebral palsy cases, whereas a substantial proportion of the cases were suspected to have either a prenatal or postnatal onset. Up to 16% of cerebral palsy cases may be preventable by placing a greater focus on the earlier changes seen in the Hon's fetal heart rate progression.


Subject(s)
Bradycardia/physiopathology , Cerebral Palsy , Fetal Distress/physiopathology , Fetal Hypoxia/physiopathology , Heart Rate, Fetal , Hypoxia, Brain/physiopathology , Nuchal Cord/physiopathology , Obstetric Labor Complications/physiopathology , Adult , Cardiotocography , Cohort Studies , Female , Fetal Blood , Humans , Infant, Newborn , Male , Nuchal Cord/epidemiology , Pregnancy , Umbilical Cord/abnormalities
2.
J Obstet Gynaecol ; 40(3): 316-323, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31976797

ABSTRACT

Analysing antepartum and intrapartum computerised cardiotocographic (cCTG) parameters in physiological term pregnancies with nuchal (NC) or body cord (BC), in order to correlate them with labour events and neonatal outcome. We enrolled 808 pregnant women, composed of 264 with 'one NC', 121 with 'multiple NCs', 39 with BC and 384 with 'no NC', were monitored from the 37th week of gestation before labour, while 49 pregnant women with 'one or more NCs' and 47 with 'no NCs' were analysed during labour. No differences in maternal characteristics, foetal pH at birth and 5-min Apgar score were observed. The birth weight was significantly lower in the 'multiple NCs' group, while 1-minute Apgar score was lower in the BC group than the other groups, respectively. No relevant differences in cCTG parameters were observed, except for LTI, Delta and number of variable decelerations in antepartum period and only variable deceleration in intrapartum period.Impact statementWhat is already known on this subject? Ultrasound cannot predict which foetuses with NCs are likely to have problem during labour. The question arose if single or multiple NC could affects FHR monitoring prior and during labour.What do the results of this study add? Computerised cardiotocography (cCTG) is a standardised method developed to reduce inter- and intra-observer variability and the poor reproducibility of visual analysis. Few studies have investigated the influence of NCs on FHR variability and, to our knowledge, no one has evaluated its linear and nonlinear characteristics in antepartum and intrapartum period using a computerised analysis system. No differences in maternal characteristics, foetal pH at birth and 5-min Apgar score were observed. Birth weight was significantly lower in the 'multiple NCs' group, while 1-min Apgar score was lower in the BC group than the other groups, respectively. Foetuses with 'one or more NCs' evidenced a larger number of prolonged second stage and meconium-stained liquor cases, while the operative vaginal delivery and emergency caesarean section rates were unchanged. No relevant differences in cCTG parameters were observed, except for LTI, Delta and number of variable decelerations in antepartum period and only variable deceleration in intrapartum period.What are the implications of these findings for clinical practice and/or further research? cCTG monitoring results confirmed their usefulness for assessing the state of good oxygenation for all foetuses investigated.


Subject(s)
Cardiotocography/statistics & numerical data , Heart Rate, Fetal/physiology , Labor, Obstetric/physiology , Nuchal Cord/physiopathology , Term Birth/physiology , Birth Weight , Delivery, Obstetric/methods , Delivery, Obstetric/statistics & numerical data , Female , Humans , Infant, Newborn , Observer Variation , Pregnancy , Reproducibility of Results , Retrospective Studies
3.
Am J Perinatol ; 37(4): 378-383, 2020 03.
Article in English | MEDLINE | ID: mdl-30818403

ABSTRACT

OBJECTIVE: This study aimed to determine the association between nuchal cord, electronic fetal monitoring parameters, and adverse neonatal outcomes. STUDY DESIGN: This was a prospective cohort study of 8,580 singleton pregnancies. Electronic fetal monitoring was interpreted, and patients with a nuchal cord at delivery were compared with those without. The primary outcome was a composite neonatal morbidity index. Logistic regression was used to adjust for confounders. RESULT: Of 8,580 patients, 2,071 (24.14%) had a nuchal cord. There was no difference in the risk of neonatal composite morbidity in patients with or without a nuchal cord (8.69 vs. 8.86%; p = 0.81). Nuchal cord was associated with category II fetal heart tracing and operative vaginal delivery (OVD) (6.4 vs. 4.3%; p < 0.01). CONCLUSION: Nuchal cord is associated with category II electronic fetal monitoring parameters, which may drive increased rates of OVD. However, there is no significant association with neonatal morbidity.


Subject(s)
Cardiotocography , Heart Rate, Fetal , Nuchal Cord , Adult , Delivery, Obstetric , Female , Humans , Infant, Newborn , Infant, Newborn, Diseases/etiology , Maternal Age , Nuchal Cord/complications , Nuchal Cord/physiopathology , Pregnancy , Pregnancy Complications , Pregnancy Outcome , Prospective Studies , Young Adult
4.
Medicina (Kaunas) ; 55(12)2019 Dec 09.
Article in English | MEDLINE | ID: mdl-31835374

ABSTRACT

Background and objectives: The objective of this study was to contribute to the evaluation of the newborn (NB) cry as a means of communication and diagnosis. Materials and Methods: The study implied the recording of the spontaneous cry of 101 NBs with no intrapartum events (control sample), and of 72 NBs with nuchal cord (study sample) from the "Bega" University Clinic of Obstetrics-Gynecology and Neonatology of Timisoara, Romania. The sound analysis was based upon: Imagistic highlighting methods, descriptive statistics, and data mining techniques. Results: The differences between the cry of NBs with no intrapartum events and that of NBs affected by nuchal cord are statistically significant regarding the volume unit meter (VUM) (p = 0.0021) and the peak point meter (PPM) (p = 0.041). Conclusions: While clinically there are no differences between the two groups, the cry recorded from the study group (nuchal cord group) shows distinctive characteristics compared to the cry recorded from the control group (eventless intrapartum NBs group).


Subject(s)
Crying/physiology , Nuchal Cord/physiopathology , Sound Spectrography/methods , Video Recording/instrumentation , Algorithms , Apgar Score , Communication , Data Mining/methods , Female , Gestational Age , Humans , Infant, Newborn , Pregnancy , Romania/epidemiology , Software
5.
Clín. investig. ginecol. obstet. (Ed. impr.) ; 40(5): 207-212, sept.-oct. 2013. ilus, tab
Article in Spanish | IBECS | ID: ibc-115864

ABSTRACT

Objetivo: Se determinaron los valores de la frecuencia cardiaca y la incidencia de dips tipos i y ii en los fetos con circular de cordón. Diseño del estudio La muestra la integraron 40 pacientes, se dividió en 2 grupos: Grupo 1: 20 pacientes embarazadas con diagnóstico de circular de cordón o grupo problema; Grupo 2: 20 pacientes con embarazo normal o grupo testigo. Se practicaron registros de frecuencia cardiaca fetal y contractilidad uterina durante 2 h. Para el análisis estadístico se utilizaron el programa SPSS® y las pruebas t de Student y Z. Resultados En el grupo problema la frecuencia cardiaca fetal (FCF) fue de 138 latidos por minuto (lat/min) y en el testigo de 135 lat/min. En el primer grupo, esta se incrementó 3 lat. Se calculó si la diferencia entre medias era o no significativa. Se utilizaron las pruebas de Z-score cuyo valor fue de 8,65 y p < 0,01: esta fue significativa. En los 2 grupos se calcularon los valores de la amplitud de las aceleraciones. Estas fueron semejantes: 24 lat. La diferencia entre medias no fue significativa. El análisis comparativo entre el peso y la talla de los recién nacidos en el grupo problema fue de 3.100 g y la talla de 50,72 cm. En el testigo fue de 2.960 g y 49,77 cm respectivamente. La diferencia entre medias no fue significativa. A los recién nacidos se les valoró con la prueba de Apgar. En el grupo problema, durante el primer minuto la calificación tuvo un rango de 7-9 y en el quinto de 8-9. En el grupo testigo las calificaciones fueron semejantes. Se cuantificaron los dips tipos i y ii . De los primeros dips se registraron 3 y de los segundos 2, uno con gran amplitud y duración. No se registraron dips tipo iii . En ninguno de los partos hubo presencia de meconio. Conclusiones En la circular de cordón floja: no hubo cambios significativos en la FCF. Circular de cordón apretada produjo: dips tipo ii de gran amplitud (AU)


Objective: To determine heart rate and the frequency of type i and ii dips in fetuses with coiling of funis. Study design: There were 40 patients in the sample, divided in two groups: group 1: consisted of 20 pregnant women with a diagnosis of coiling of funis; group ii consisted of 20 patients with a normal pregnancy. Fetal heart rate (HR) and uterine contractility were recorded for 2 hours. For the statistical analysis, the SPSS® package, Z-score and Student’s t-test were used. Results: Fetal HR was 138 beats/min in group 1 and 135 beats/min in group ii. The difference between medians (Z-score) was 8.65, which was significant (P<.01).Amplitude and accelerations were calculated in both groups, with similar results (24 beats).The difference in means was not significant. The mean weight and height were compared in the two groups. Mean weight was 3,100 g in group 1 and 2,960 in group 1, while mean height was 50.72 cm in group i and 49.77 in group 2.The difference in means was not significant. Apgar tests were performed in both groups. In group 1, Apgar scores ranged from 7-9 at1 minute and from 8-9 at 5 minutes. Values were similar in group 2.Type i dips gave a reading of 3, and type ii dips a reading of 2 (one with marked height and duration). No type iii dips were observed. No meconium was found in any of the deliveries. Conclusions: In pregnancies with loosely coiled funises, there were no significant changes in fetal HR. In pregnancies with tightly coiled funises, type ii dips with wide amplitude and marked duration were found (AU)


Subject(s)
Humans , Female , Pregnancy , Nuchal Cord/physiopathology , Heart Rate, Fetal/physiology , Fetal Hypoxia/physiopathology , Uterine Contraction/physiology , Case-Control Studies , Risk Factors , Obstetric Labor Complications
6.
J Obstet Gynaecol Res ; 38(2): 358-63, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22176493

ABSTRACT

AIM: The purpose of the present study was to compare and analyze differences in antepartal fetal heart rate (FHR) parameters during pregnancy and pregnancy outcomes in normal fetuses and fetuses with nuchal cord (NC). MATERIAL AND METHODS: We surveyed all non-stress test (NST) data acquired using a computerized FHR analysis system at Hanyang University Hospital between 2005 and 2008, and selected 150 cases that had NC. NSTs were performed between 37 and 42 weeks of gestation. Subjects were divided into three groups by the number of NCs: no NC and normal (n = 300), single (n = 124) and multiple NCs (n = 26). Neonatal outcomes were compared, and FHR parameters analyzed using computerized fetal monitoring system. RESULTS: FHR variability, with respect to amplitude (AMP) and mean minute range (MMR), was lower in the multiple NCs group than in the normal group (18.04 ± 0.38 vs 14.54 ± 1.10 bpm, P = 0.0207; 55.69 ± 1.22 vs 44.35 ± 3.41 ms, P = 0.0145, respectively). There were no other statistically significant differences of FHR parameters between the three groups. Baby weight was significantly lower in the multiple NCs group than in the normal group (3317 ± 24 vs 3054 ± 55; P = 0.0008), and there were no other significant differences between the groups. CONCLUSION: Computerized analysis of FHR would be helpful to assess fetal status, especially in cases of multiple NCs. Multiple NCs may be a subliminal risk factor for the babies even though they present no complications at delivery.


Subject(s)
Heart Rate, Fetal , Nuchal Cord/physiopathology , Female , Humans , Pregnancy , Retrospective Studies , Risk Factors
7.
Prog. obstet. ginecol. (Ed. impr.) ; 54(3): 136-139, mar. 2011. ilus
Article in Spanish | IBECS | ID: ibc-86183

ABSTRACT

La gestación gemelar monocorial monoamniótica presenta alto riesgo de muerte fetal en relación a complicaciones generales de las gestaciones gemelares así como específicas de la monoamniocidad, siendo la más grave la muerte fetal por entrecruzamiento de cordones, el cual se presenta en prácticamente la totalidad de los casos. En el manejo de la gestación monocorial monoamniótica es fundamental un correcto diagnóstico precoz ecográfico, así como un manejo y vigilancia estricta para detectar signos de entrecruzamiento de cordones que permitan evitar la progresión a muerte fetal intraútero. La necesidad de hospitalización y el momento de finalización de la gestación siguen generando controversia en la literatura médica (AU)


Monochorial monoamniotic twins are at high risk of fetal death due to the general complications seen in multiple gestations, as well as those specific to this type of pregnancy. The most severe complication in these pregnancies is fetal death due to cord entanglement, which occurs in almost all cases. Early ultrasonographic diagnosis and intensive prenatal surveillance are essential for the early detection of cord entanglement and the prevention of fetal death. The need for in-hospital management and the exact gestational age for delivery continue to generate controversy in the literature (AU)


Subject(s)
Humans , Female , Pregnancy , Adult , Nuchal Cord/complications , Nuchal Cord/diagnosis , Nuchal Cord/surgery , Pregnancy Complications/diagnosis , Pregnancy Complications/surgery , Fetal Mortality/trends , Nuchal Cord/mortality , Nuchal Cord/physiopathology , Indicators of Morbidity and Mortality , Fetal Death/prevention & control , Fetal Death/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...