Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Chem Pharm Bull (Tokyo) ; 69(1): 26-31, 2021.
Article in English | MEDLINE | ID: mdl-33390518

ABSTRACT

As a new absolute quantitation method for low-molecular compounds, quantitative NMR (qNMR) has emerged. In the Japanese Pharmacopoeia (JP), 15 compounds evaluated by qNMR are listed as reagents used as the HPLC reference standards in the assay of crude drug section of the JP. In a previous study, we revealed that humidity affects purity values of hygroscopic reagents and that (i) humidity control before and during weighing is important for a reproducible preparation and (ii) indication of the absolute amount (not purity value), which is not affected by water content, is important for hygroscopic products determined by qNMR. In this study, typical and optimal conditions that affect the determination of the purity of ginsenoside Rb1 (GRB1), saikosaponin a (SSA), and barbaloin (BB) (i.e., hygroscopic reagents) by qNMR were examined. First, the effect of humidity before and during weighing on the purity of commercial GRB1, with a purity value determined by qNMR, was examined. The results showed the importance afore-mentioned. The results of SSA, which is relatively unstable in the dissolved state, suggested that the standardization of humidity control before and during weighing for a specific time provides a practical approach for hygroscopic products. In regard to BB, its humidity control for a specific time, only before weighing, is enough for a reproducible purity determination.


Subject(s)
Anthracenes/analysis , Ginsenosides/analysis , Hygroscopic Agents/analysis , Oleanolic Acid/analogs & derivatives , Saponins/analysis , Anthracenes/standards , Ginsenosides/standards , Humidity , Hygroscopic Agents/standards , Japan , Magnetic Resonance Spectroscopy/standards , Oleanolic Acid/analysis , Oleanolic Acid/standards , Saponins/standards
2.
Yakugaku Zasshi ; 140(8): 1063-1069, 2020.
Article in Japanese | MEDLINE | ID: mdl-32741864

ABSTRACT

Quantitative NMR (qNMR) has been developed as an absolute quantitation method to determine the purity or content of organic compounds including marker compounds in crude drugs. The "qNMR test" has been introduced into the crude-drug section of the Japanese Pharmacopoeia (JP) for determining the purity of reagents used for the assay in the JP. In Supplement II to the JP 17th edition published in June 2019, fifteen compounds adopted qNMR test were listed as the reagents for the assay. To establish the "qNMR test" in the crude drug section of the JP, there were several problems to be solved. Previously, we reported that the handling impurity signals from reference substances and targeted marker compounds, chemical shifts of reference substances, and peak unity of signals of targeted marker compounds are important factors to conduct qNMR measurements with intended accuracy. In this study, we investigated that the hygroscopicity of reagents could cause the changes in the compounds' purity depending on increasing their water content. Twenty-one standard products used for the crude-drug test in JP were examined by water sorption-desorption analysis, and ginsenosides and saikosaponins were found to be hygroscopic. To prepare a sample solution of saikosaponin b2 for qNMR analysis, samples need to be maintained for 18 h at 25°C and 76% relative humidity; further, samples need to be weighed at the same humidity for the qNMR analysis.


Subject(s)
Drug Contamination/prevention & control , Hygroscopic Agents/chemistry , Hygroscopic Agents/standards , Indicators and Reagents/standards , Magnetic Resonance Spectroscopy/methods , Pharmacopoeias as Topic/standards , Ginsenosides/chemistry , Ginsenosides/standards , Humidity , Japan , Oleanolic Acid/analogs & derivatives , Oleanolic Acid/chemistry , Oleanolic Acid/standards , Psychotherapy, Brief , Saponins/chemistry , Saponins/standards , Temperature , Water/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...