Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.340
Filter
1.
Sensors (Basel) ; 24(9)2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38732777

ABSTRACT

Optical fiber sensors are extensively employed for their unique merits, such as small size, being lightweight, and having strong robustness to electronic interference. The above-mentioned sensors apply to more applications, especially the detection and monitoring of vital signs in medical or clinical. However, it is inconvenient for daily long-term human vital sign monitoring with conventional monitoring methods under the uncomfortable feelings generated since the skin and devices come into direct contact. This study introduces a non-invasive surveillance system that employs an optical fiber sensor and advanced deep-learning methodologies for precise vital sign readings. This system integrates a monitor based on the MZI (Mach-Zehnder interferometer) with LSTM networks, surpassing conventional approaches and providing potential uses in medical diagnostics. This could be potentially utilized in non-invasive health surveillance, evaluation, and intelligent health care.


Subject(s)
Deep Learning , Optical Fibers , Vital Signs , Humans , Vital Signs/physiology , Monitoring, Physiologic/methods , Monitoring, Physiologic/instrumentation , Neural Networks, Computer
2.
Anal Methods ; 16(20): 3263-3270, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38738477

ABSTRACT

To detect redox potential evolution during the initial stage of an acute wound, a redox-sensitive SERS-active optical fiber was fabricated by integrating redox-sensitive SERS probes in a hole of an optical fiber. The redox-sensitive SERS-active optical fibers carried redox-sensitive SERS probes into the inside of a wound to sense its redox potential. The laser was transmitted to the redox-sensitive SERS probes in the body by optical fibers, and the SERS signals of the redox-sensitive SERS probes were transferred out of the body by optical fibers to indicate the redox potentials in the wound. The redox-sensitive SERS probes dynamically sensed the redox potential in vivo, and their SERS signals were collected constantly to indicate the redox potentials. The assessments in vivo and in vitro proved the responsiveness of redox-sensitive SERS-active optical fibers. The redox potential evolution during the initial stage of an acute wound with the treatments of different concentrations of glucose was detected to verify the feasibility of redox-sensitive SERS-active optical fibers to dynamically detect redox potentials in vivo. The redox-sensitive SERS-active optical fiber would be a versatile tool to explore the roles of redox potentials in living organisms.


Subject(s)
Optical Fibers , Oxidation-Reduction , Spectrum Analysis, Raman , Spectrum Analysis, Raman/methods , Animals , Wound Healing , Male , Mice
3.
Water Res ; 257: 121682, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38718654

ABSTRACT

Photocatalyst-coated optical fibers (P-OFs) using UV-A LEDs offer a highly promising solution for the degradation of micropollutants within municipal, reuse, industrial or home distribution systems, by integrating P-OFs into water storage tanks. P-OFs have photocatalysts attached to bundles of optical fibers, enabling their direct deployment within tanks. This eliminates the necessity for photocatalyst slurries, which would require additional membrane or separation systems. However, a current limitation of P-OFs is light management, specifically light oversaturation of the coated photocatalysts and short light transmission distances along fibers. This study overcomes this limitation and reveals strategies to improve the light dissipation uniformity along P-OFs, and demonstrates the performance of P-OFs on degrading a model micropollutant, carbamazepine (CBZ). Key tunable variables of fibers and light emission conditions, including photocatalyst coating patchiness (p), minimum light incident angles (θm), radiant flux launched to fibers (Φi), and fiber diameters (D), were modeled to establish their relationships with the light dissipation uniformity in TiO2-coated quartz optical fibers (TiO2-QOFs). We then validated modeling insights by conducting experiments to examine how these variables influence the generation of evanescent waves which are localized energy on fiber surfaces, leading to either photocatalyst activation or the recapture of unused light back into fibers. We observed substantial enhancements in evanescent waves generation by decreasing p and increasing θm, resulting in uniform light dissipation which reduces light oversaturation and improves light transmission distances. Moreover, these optimizations led to a remarkable three-fold improvement in CBZ degradation rates and a 65% reduction in energy consumption. Such improvement substantially reduces the capital and operational cost and enhances practicality of energy-efficient photocatalysis without additional chemical oxidants for micropollutant degradation in water storage tanks.


Subject(s)
Optical Fibers , Quartz , Titanium , Water Pollutants, Chemical , Titanium/chemistry , Quartz/chemistry , Water Pollutants, Chemical/chemistry , Catalysis , Water Purification/methods , Carbamazepine/chemistry
4.
Int J Mol Sci ; 25(10)2024 May 17.
Article in English | MEDLINE | ID: mdl-38791532

ABSTRACT

The development of photocurable compositions is in high demand for the manufacture of functional materials for electronics, optics, medicine, energy, etc. The properties of the final photo-cured material are primarily determined by the initial mixture, which needs to be tuned for each application. In this study we propose to use simple systems based on di(meth)acrylate, polyimide and photoinitiator for the preparation of new photo-curable compositions. It was established that a fluorinated cardo copolyimide (FCPI) based on 2,2-bis-(3,4-dicarboxydiphenyl)hexafluoropropane dianhydride, 9,9-bis-(4-aminophenyl)fluorene and 2,2-bis-(4-aminophenyl)hexafluoropropane (1.00:0.75:0.25 mol) has excellent solubility in di(met)acrylates. This made it possible to prepare solutions of FCPI in such monomers, to study the effect of FCPI on the kinetics of their photopolymerization in situ and the properties of the resulting polymers. According to the obtained data, the solutions of FCPI (23 wt.%) in 1,4-butanediol diacrylate (BDDA) and FCPI (15 wt.%) in tetraethylene glycol diacrylate were tested for the formation of the primary protective coatings of the silica optical fibers. It was found that the new coating of poly(BDDA-FCPI23%) can withstand prolonged annealing at 200 °C (72 h), which is comparable or superior to the known most thermally stable photo-curable coatings. The proposed approach can be applied to obtain other functional materials.


Subject(s)
Optical Fibers , Polymerization , Silicon Dioxide , Silicon Dioxide/chemistry , Solubility , Imides/chemistry , Temperature , Acrylates/chemistry , Polymers/chemistry , Halogenation , Photochemical Processes
5.
Anal Chim Acta ; 1309: 342665, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38772653

ABSTRACT

BACKGROUND: The concentration of cytochrome C is demonstrated to be an effective indicator of the microbial corrosion strength of metals. Traditional cytochrome C sensor can detect cytochrome C with a low detection limit, but their use is limited by their high cost, cumbersome operation, and susceptibility to malignant environments. In addition, studies on the monitoring of cytochrome C in the field of microbial corrosion has still not been carried out. Therefore, there is a need for a highly sensitive, selective, low-cost, anti-interference, and stable cytochrome C sensor with online monitoring and remote sensing capabilities for in-situ measurement of microbial corrosion strength. RESULTS: This paper proposed a highly sensitive label-free fiber-optic sensor based on Mach-Zehnder interferometer (MZI) for in-situ measurement of the microbial corrosion marker cytochrome C. Two-dimensional Ti2C-MXene material is uniformly immobilized onto the surface of the sensing area to improve the sensitivity, hydrophilicity, and specific surface area of the sensing area, as well as to facilitate the immobilization of specific sensitive materials. The cytochrome C antibody is modified on the surface of Ti2C-MXene to specifically recognize cytochrome C, whose concentration variation can be measured by monitoring the spectral shift of MZI sensor. Results demonstrate a measurement sensitivity of 1.428 nm/µM for cytochrome C concentrations ranging from 0 to 7.04 µM. The detection limit of the sensor is calculated to be 0.392 µM with remarkable performance, including selectivity, stability, and reliability. Besides, the measurement result of the proposed sensor in real microbial corrosive environment is consistent with that of the ideal environment. SIGNIFICANCE AND NOVELTY: This is the first instance of achieving in-situ and label-free measurement of cytochrome C by using a fiber-optic MZI sensor, which undoubtedly provides a feasible solution for the effective monitoring of microbial metal corrosion in the environment.


Subject(s)
Cytochromes c , Fiber Optic Technology , Interferometry , Titanium , Cytochromes c/analysis , Cytochromes c/metabolism , Titanium/chemistry , Biosensing Techniques/methods , Limit of Detection , Optical Fibers , Corrosion
6.
Biosens Bioelectron ; 257: 116312, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38657380

ABSTRACT

Pre-eclampsia (PE) is a life-threatening complication that occurs during pregnancy, affecting a large number of pregnant women and newborns worldwide. Rapid, on-site and affordable screening of PE at an early stage is necessary to ensure timely treatment and minimize both maternal and neonatal morbidity and mortality rates. Placental growth factor (PlGF) is an angiogenic blood biomarker used for PE diagnosis. Herein, we report the plasmonic fiber optic absorbance biosensor (P-FAB) strategy for detecting PlGF at femtomolar concentration using polymethyl methacrylate (PMMA) based U-bent polymeric optical fiber (POF) sensor probes. A novel poly(amidoamine) (PAMAM) dendrimer based PMMA surface modification is established to obtain a greater immobilization of the bioreceptors compared to a linear molecule like hexamethylenediamine (HMDA). Plasmonic sandwich immunoassay was realized by immobilizing the mouse anti-PlGF (3H1) on the U-bent POF sensor probe surface and gold nanoparticles (AuNP) labels conjugated with mouse anti-PlGF (6H9). The POF sensor probes could measure PlGF within 30 min using the P-FAB strategy. The limit-of-detection (LoD) was found to be 0.19 pg/mL and 0.57 pg/mL in phosphate-buffered saline and 10× diluted serum, respectively. The clinical sample testing, with eleven positive and eleven negative preeclamptic pregnancy samples, successfully confirmed the accuracy, reliability, specificity, and sensitivity of the P-FAB based POF sensor platform, thereby paving the way for cost-effective technology for PlGF detection and its potential for pre-eclampsia diagnosis.


Subject(s)
Biosensing Techniques , Dendrimers , Gold , Metal Nanoparticles , Optical Fibers , Placenta Growth Factor , Pre-Eclampsia , Pre-Eclampsia/diagnosis , Pre-Eclampsia/blood , Pregnancy , Female , Humans , Dendrimers/chemistry , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Placenta Growth Factor/blood , Gold/chemistry , Metal Nanoparticles/chemistry , Limit of Detection , Immunoassay/methods , Immunoassay/instrumentation , Fiber Optic Technology/instrumentation , Animals , Mice , Polymethyl Methacrylate/chemistry
7.
J Dent ; 145: 104998, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38636650

ABSTRACT

OBJECTIVES: The study aimed to introduce a novel two-step optical fiber-based photo-activation of dental resin-based composites (RBCs) for reducing polymerization shrinkage stress (PSS). METHODS: Proposed protocol design - in the first step, two flexible plastic optical fibers connected to a dental light curing unit (LCU), were used as light guides inserted into the filling to initiate low-irradiance polymerization from within; in the second step, fibers were extracted and remaining voids were filled with RBC, followed by conventional high-irradiance curing to finalize polymerization. Three bulk-fill RBCs were tested (Beautifil-Bulk Restorative, Filtek Bulk-fill Posterior, Tetric PowerFill) using tooth cavity models. Three non-invasive examination techniques were employed: Digital Holographic Interferometry, Infrared Thermography, and Raman spectroscopy for monitoring model deformation, RBC temperature change, and degree of conversion (DC), respectively. A control group (for each examined RBC) underwent conventional photo-activation. RESULTS: The experimental protocol significantly reduced model deformation by 15 - 35 %, accompanied by an 18 - 54 % reduction in RBC temperature change, emphasizing the impact of thermal shrinkage on PSS. Real-time measurements of deformation and temperature provided indirect insights into reaction dynamics and illuminated potential mechanisms underlying PSS reduction. After a 24-hour dark-storage period, DC outcomes comparable to conventional curing were observed, affirming the clinical applicability of the method. CONCLUSIONS: Protocol involving the use of two 1.5 mm fibers in the first step (300 mW/cm2 x 10 s), followed by a second conventional curing step (1000 mW/cm2 x 10 s), is recommended to achieve the desired PSS reduction, while maintaining adequate DC and ensuring efficient clinical application. CLINICAL SIGNIFICANCE: Obtained PSS reduction offers promise in potentially improving the performance of composite restorations. Additionally, leveraging the flexibility of optical fibers improves light guide approach for restorations on posterior teeth. Meanwhile, implementation in clinical practice is easily achievable by coupling the fibers with commercial dental LCUs using the provided plastic adapter.


Subject(s)
Composite Resins , Materials Testing , Optical Fibers , Polymerization , Composite Resins/chemistry , Composite Resins/radiation effects , Humans , Curing Lights, Dental , Dental Materials/chemistry , Dental Materials/radiation effects , Temperature , Spectrum Analysis, Raman , Light-Curing of Dental Adhesives/methods , Stress, Mechanical , Surface Properties
8.
Biosensors (Basel) ; 14(4)2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38667166

ABSTRACT

Heart failure (HF) is a clinical entity included in cardiovascular diseases affecting millions of people worldwide, being a leading cause of hospitalization of older adults, and therefore imposing a substantial economic burden on healthcare systems. HF is characterized by dyspnea, fatigue, and edema associated with elevated blood levels of natriuretic peptides, such as N Terminal pro-B-type Natriuretic Peptide (NT-proBNP), for which there is a high demand for point of care testing (POCT) devices. Optical fiber (OF) biosensors offer a promising solution, capable of real-time detection, quantification, and monitoring of NT-proBNP concentrations in serum, saliva, or urine. In this study, immunosensors based on plasmonic uncladded OF tips were developed using OF with different core diameters (200 and 600 µm). The tips were characterized to bulk refractive index (RI), anddetection tests were conducted with NT-proBNP concentrations varying from 0.01 to 100 ng/mL. The 200 µm sensors showed an average total variation of 3.6 ± 2.5 mRIU, an average sensitivity of 50.5 mRIU/ng·mL-1, and a limit of detection (LOD) of 0.15 ng/mL, while the 600 µm sensors had a response of 6.1 ± 4.2 mRIU, a sensitivity of 102.8 mRIU/ng·mL-1, and an LOD of 0.11 ng/mL. Control tests were performed using interferents such as uric acid, glucose, and creatinine. The results show the potential of these sensors for their use in biological fluids.


Subject(s)
Biosensing Techniques , Natriuretic Peptide, Brain , Optical Fibers , Peptide Fragments , Natriuretic Peptide, Brain/blood , Humans , Peptide Fragments/blood , Peptide Fragments/analysis , Heart Failure/diagnosis , Limit of Detection
9.
Anal Chem ; 96(18): 6906-6913, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38656893

ABSTRACT

Glycerol tributyrate as a low-density lipoprotein plays a crucial role in drug development and food safety. In this work, a novel high-stability fiber optic sensor for glyceryl tributyrate based on the poly(acrylic acid) (PAA) and chitosan (CS) composite hydrogel embedding method is first proposed. Compared with traditional functionalization, the lipase in a polymer network structure used in this article can not only avoid chemical reactions that cause damage to the enzyme structure but also avoid the instability of ionic bonds and physical adsorption. Therefore, the PAA/CS hydrogel method proposed in this article can effectively retain enzyme structure. First, the impact of different layers (one to five layers) of PAA/CS on pH sensing performance was explored, and it was determined that layers 1-3 could be used for subsequent sensing experiments. Within the linear detection range of 0.5-10 mM, the detection sensitivities of the one to three layers of the biosensor are divided into 0.65, 0.95, and 1.51 nm/mM, respectively, with the three layers having the best effect. When the number of coating layers is three, the detection limit of the sensor is 0.47 mM, meeting the millimole level detection standard for anticancer requirement. Furthermore, the stability and selectivity of the sensor (in the presence of hemoglobin, urea, cholesterol, acetylcholine, and glucose) were analyzed. The three-layer sensor is used for sample detection. At concentrations of 1-10 mM, the absolute value of the recovery percentage (%) is 82-99%, which can accurately detect samples. The sensor proposed in this paper has the advantages of low sample consumption, high sensitivity, simple structure, and label-free measurement. The enzyme-embedding method provides a new route for rapid and reliable glyceryl tributyrate detection, which has potential applications in food safety as well as the development of anticancer drugs.


Subject(s)
Acrylic Resins , Chitosan , Optical Fibers , Surface Plasmon Resonance , Acrylic Resins/chemistry , Chitosan/chemistry , Hydrogels/chemistry , Limit of Detection , Lipase/chemistry , Lipase/metabolism , Biosensing Techniques/methods
10.
Sci Rep ; 14(1): 9446, 2024 04 24.
Article in English | MEDLINE | ID: mdl-38658694

ABSTRACT

To validate the feasibility of a fiber-optic pressure sensor-based pressure measurement device for monitoring intrarenal pressure and to analyze the effects of ureteral acess sheath (UAS) type, surgical location, perfusion flow rate, and measurement location on intrarenal pressure (IRP). The measurement deviations and response times to transient pressure changes were compared between a fiber-optic pressure sensing device and a urodynamic device IRP in an in vitro porcine kidney and in a water tank. Finally, pressure measurements were performed in anesthetized female pigs using fiber-optic pressure sensing device with different UAS, different perfusion flow rates, and different surgical positions at different renal calyces and ureteropelvic junctions (UPJ). According to our operation, the result is fiber optic pressure sensing devices are highly accurate and sensitive. Under the same conditions, IRP varied among different renal calyces and UPJ (P < 0.05). IRP was lowest at 50 ml/min and highest at 150 ml/min (P < 0.05). Surgical position had a significant effect on IRP (P < 0.05). 12/14 Fr UAS had a lower IRP than 11/13 Fr UAS. Therefore fiber optic pressure sensing devices are more advantageous for IRP measurements. In ureteroscopy, the type of ureteral sheath, the surgical position, the perfusion flow rate, and the location of the measurement all affect the intrarenal pressure value.


Subject(s)
Fiber Optic Technology , Kidney , Pressure , Ureteroscopy , Animals , Fiber Optic Technology/instrumentation , Swine , Female , Kidney/physiology , Ureteroscopy/instrumentation , Ureteroscopy/methods , Optical Fibers , Urodynamics
11.
Anal Chem ; 96(14): 5446-5454, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38556805

ABSTRACT

In this study, a novel integrated photoelectrochemical (PEC) sensor platform was proposed, utilizing an optical fiber (OF) as the working electrode for guided in situ light. A CdS quantum dots (QDs)/ZnO nanosheets (NSs) n-n heterojunction was quickly and easily constructed on the OF surface by successive ionic layer adsorption and reaction (SILAR). Au nanoparticles (NPs)@dsDNA as a capturing probe were modified on the CdS QDs/ZnO NSs@OF (CZ@OF). Due to the energy transfer between Au NPs@dsDNA and CdS QDs, the resultant opto-electrode has a lower background near zero, enabling the "signal-on" detection of biomarkers (interleukin-6 (IL-6) as a model). The OF-PEC biosensor demonstrated a wide linear range from 1 to 100 pg mL-1 with a regression coefficient (R2) of 0.9958 and an impressive detection limit (LOD) of 0.19 pg mL-1. More significantly, the proposed OF-PEC can be successfully used for the detection of IL-6 in serum samples from patients with pulmonary arterial hypertension, and it showed consistency and is more sensitive to trace concentrations compared to BD FACSCanto II flow cytometry used at the hospital. This holds significance for an early disease diagnosis. Therefore, the proposed OF-PEC not only achieves integration of the light source and sensing interface but also enables sensitive and accurate "signal-on" detection of IL-6. Furthermore, due to the flexibility and remote detection capabilities of OF, the application of OF-PEC is expected to be expanded more widely. This approach opens up possibilities for advances in PEC sensing.


Subject(s)
Biosensing Techniques , Metal Nanoparticles , Quantum Dots , Zinc Oxide , Humans , Electrochemical Techniques , Cytokines , Interleukin-6 , Gold , Adsorption , Optical Fibers , Electrodes , Limit of Detection
12.
J Biomed Opt ; 29(4): 046001, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38585417

ABSTRACT

Significance: Endoscopic screening for esophageal cancer (EC) may enable early cancer diagnosis and treatment. While optical microendoscopic technology has shown promise in improving specificity, the limited field of view (<1 mm) significantly reduces the ability to survey large areas efficiently in EC screening. Aim: To improve the efficiency of endoscopic screening, we propose a novel concept of end-expandable endoscopic optical fiber probe for larger field of visualization and for the first time evaluate a deep-learning-based image super-resolution (DL-SR) method to overcome the issue of limited sampling capability. Approach: To demonstrate feasibility of the end-expandable optical fiber probe, DL-SR was applied on simulated low-resolution microendoscopic images to generate super-resolved (SR) ones. Varying the degradation model of image data acquisition, we identified the optimal parameters for optical fiber probe prototyping. The proposed screening method was validated with a human pathology reading study. Results: For various degradation parameters considered, the DL-SR method demonstrated different levels of improvement of traditional measures of image quality. The endoscopists' interpretations of the SR images were comparable to those performed on the high-resolution ones. Conclusions: This work suggests avenues for development of DL-SR-enabled sparse image reconstruction to improve high-yield EC screening and similar clinical applications.


Subject(s)
Barrett Esophagus , Deep Learning , Esophageal Neoplasms , Humans , Optical Fibers , Esophageal Neoplasms/diagnostic imaging , Barrett Esophagus/pathology , Image Processing, Computer-Assisted
13.
Biomed Phys Eng Express ; 10(3)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38626737

ABSTRACT

A novel fiber optic biosensor was purposed for a new approach to monitor amyloid beta protein fragment 1-42 (Aß42) for Alzheimer's Disease (AD) early detection. The sensor was fabricated by etching a part of fiber from single mode fiber loop in pure hydrofluoric acid solution and utilized as a Local Optical Refractometer (LOR) to monitor the change Aß42 concentration in Artificial Cerebrospinal Fluid (ACSF). The Fiber Loop Ringdown Spectroscopy (FLRDS) technique is an ultra-sensitive measurement technique with low-cost, high sensitivity, real-time measurement, continuous measurement and portability features that was utilized with a fiber optic sensor for the first time for the detection of a biological signature in an ACSF environment. Here, the measurement is based on the total optical loss detection when specially fabricated sensor heads were immersed into ACSF solutions with and without different concentrations of Aß42 biomarkers since the bulk refractive index change was performed. Baseline stability and the reference ring down times of the sensor head were measured in the air as 0.87% and 441.6µs ± 3.9µs, respectively. Afterward, the total optical loss of the system was measured when the sensor head was immersed in deionized water, ACSF solution, and ACSF solutions with Aß42 in different concentrations. The lowest Aß42 concentration of 2 ppm was detected by LOR. Results showed that LOR fabricated by single-mode fibers for FLRDS system design are promising candidates to be utilized as fiber optic biosensors after sensor head modification and have a high potential for early detection applications of not only AD but possibly also several fatal diseases such as diabetes and cancer.


Subject(s)
Alzheimer Disease , Amyloid beta-Peptides , Biosensing Techniques , Early Diagnosis , Fiber Optic Technology , Peptide Fragments , Spectrum Analysis , Alzheimer Disease/diagnosis , Amyloid beta-Peptides/analysis , Humans , Fiber Optic Technology/methods , Peptide Fragments/analysis , Biosensing Techniques/methods , Spectrum Analysis/methods , Optical Fibers , Biomarkers/analysis , Refractometry , Equipment Design
14.
Opt Express ; 32(6): 10077-10092, 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38571228

ABSTRACT

Every year, millions of people suffer some form of illness associated with the consumption of contaminated food. Escherichia coli (E. coli), found in the intestines of humans and other animals, is commonly associated with various diseases, due to the existence of pathogenic strains. Strict monitoring of food products for human consumption is essential to ensure public health, but traditional cell culture-based methods are associated with long waiting times and high costs. New approaches must be developed to achieve cheap, fast, and on-site monitoring. Thus, in this work, we developed optical fiber sensors based on surface plasmon resonance. Gold and cysteamine-coated fibers were functionalized with anti-E. coli antibody and tested using E. coli suspensions with concentrations ranging from 1 cell/mL to 105 cells/mL. An average logarithmic sensitivity of 0.21 ± 0.01 nm/log(cells/mL) was obtained for three independent assays. An additional assay revealed that including molybdenum disulfide resulted in an increase of approximately 50% in sensitivity. Specificity and selectivity were also evaluated, and the sensors were used to analyze contaminated water samples, which verified their promising applicability in the aquaculture field.


Subject(s)
Biosensing Techniques , Surface Plasmon Resonance , Animals , Humans , Surface Plasmon Resonance/methods , Escherichia coli , Optical Fibers , Biosensing Techniques/methods , Immunoassay
15.
Biosens Bioelectron ; 253: 116191, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38460209

ABSTRACT

To alleviate the discomfort associated with frequent blood glucose detection in diabetic patients, a novel non-invasive tear glucose biosensor has been developed. This involved the design and preparation of a photoelectrochemical probe based on an optical fiber and biological enzymes. One end of the optical fiber connects to a light source, acting as an energy source and imparting, self-powered capability to the biosensor. The opposite end is loaded with nanomaterials and glucose oxidase, designed for insertion into the sample to realize photoelectrochemical sensing. This innovative configuration not only improves the integration of the biosensor but is also suitable for analyzing minuscule voluminal samples. The results show that the proposed biosensor exhibits a linear range from 10 nM to 100 µM, possesses a low detection limit of 4.1 nM and a short response time of 0.7 s. Benefiting from the high selectivity of the enzyme, the proposed biosensor demonstrates excellent resistance to the interference of common tear components. In summary, this work provides a more effective method for non-invasive glucose detection and affords valuable ideas for the design and fabrication of non-invasive and self-powered biosensors.


Subject(s)
Biosensing Techniques , Optical Fibers , Humans , Biosensing Techniques/methods , Glucose , Blood Glucose , Glucose Oxidase
16.
Sensors (Basel) ; 24(6)2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38544254

ABSTRACT

The accuracy and efficacy of medical treatment would be greatly improved by the continuous and real-time monitoring of protein biomarkers. Identification of cancer biomarkers in patients with solid malignant tumors is receiving increasing attention. Existing techniques for detecting cancer proteins, such as the enzyme-linked immunosorbent assay, require a lot of work, are not multiplexed, and only allow for single-time point observations. In order to get one step closer to clinical usage, a dynamic platform for biosensing the cancer biomarker CD44 using a single-mode optical fiber-based ball resonator biosensor was designed, constructed and evaluated in this work. The main novelty of the work is an in-depth study of the capability of an in-house fabricated optical fiber biosensor for in situ detection of a cancer biomarker (CD44 protein) by conducting several types of experiments. The main results of the work are as follows: (1) Calibration of the fabricated fiber-optic ball resonator sensors in both static and dynamic conditions showed similar sensitivity to the refractive index change demonstrating its usefulness as a biosensing platform for dynamic measurements; (2) The fabricated sensors were shown to be insensitive to pressure changes further confirming their utility as an in situ sensor; (3) The sensor's packaging and placement were optimized to create a better environment for the fabricated ball resonator's performance in blood-mimicking environment; (4) Incubating increasing protein concentrations with antibody-functionalized sensor resulted in nearly instantaneous signal change indicating a femtomolar detection limit in a dynamic range from 7.1 aM to 16.7 nM; (5) The consistency of the obtained signal change was confirmed by repeatability studies; (6) Specificity experiments conducted under dynamic conditions demonstrated that the biosensors are highly selective to the targeted protein; (7) Surface morphology studies by AFM measurements further confirm the biosensor's exceptional sensitivity by revealing a considerable shift in height but no change in surface roughness after detection. The biosensor's ability to analyze clinically relevant proteins in real time with high sensitivity offers an advancement in the detection and monitoring of malignant tumors, hence improving patient diagnosis and health status surveillance.


Subject(s)
Biosensing Techniques , Neoplasms , Humans , Biomarkers, Tumor , Biosensing Techniques/methods , Fiber Optic Technology/methods , Optical Fibers , Proteins , Neoplasms/diagnosis , Hyaluronan Receptors
17.
Biosens Bioelectron ; 254: 116189, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38507927

ABSTRACT

Plasmonic optical fiber-based biosensors are currently in their early stages of development as practical and integrated devices, gradually making their way towards the market. While the majority of these biosensors operate using white light and multimode optical fibers (OFs), our approach centers on single-mode OFs coupled with tilted fiber Bragg gratings (TFBGs) in the near-infrared wavelength range. Our objective is to enhance surface sensitivity and broaden sensing capabilities of OF-based sensors to develop in situ sensing with remote interrogation. In this study, we comprehensively assess their performance in comparison to the gold-standard plasmonic reference, a commercial device based on the Kretschmann-Raether prism configuration. We present their refractive index sensitivity and their capability for insulin sensing using a dedicated microfluidics approach. By optimizing a consistent surface biotrapping methodology, we elucidate the dynamic facets of both technologies and highlight their remarkable sensitivity to variations in bulk and surface properties. The one-to-one comparison between both technologies demonstrates the reliability of optical fiber-based measurements, showcasing similar experimental trends obtained with both the prismatic configuration and gold-coated TFBGs, with an even enhanced limit of detection for the latter. This study lays the foundation for the detection of punctual molecular interactions and opens the way towards the detection of spatially and temporally localized events on the surface of optical probes.


Subject(s)
Biosensing Techniques , Optical Fibers , Biosensing Techniques/methods , Insulin , Benchmarking , Reproducibility of Results
18.
Biosens Bioelectron ; 254: 116232, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38520984

ABSTRACT

Healthcare system is undergoing a significant transformation from a traditional hospital-centered to an individual-centered one, as a result of escalating chronic diseases, ageing populations, and ever-increasing healthcare costs,. Wearable sensors have become widely used in health monitoring systems since the COVID-19 pandemic. They enable continuous measurement of important health indicators like body temperature, wrist pulse, respiration rate, and non-invasive bio fluids like saliva and perspiration. Over the last few decades, the development has mostly concentrated on electrochemical and electrical wearable sensors. However, due to the drawbacks of such sensors, such as electronic waste, electromagnetic interference, non-electrical security, and poor performance, researchers are exhibiting a strong interest in optical principle-based systems. Fiber-based optical wearables are among the most promising healthcare systems because of advancements in high-sensitivity, durable, multiplexed sensing, and simple integration with flexible materials to improve wearability and simplicity. We present an overview of recent developments in optical fiber-based wearable sensors, focusing on two mechanisms: wavelength interrogation and intensity modulation for the detection of body temperature, pulse rate, respiration rate, body movements, and biomedical noninvasive fluids, with a thorough examination of their benefits and drawbacks. This review also focuses on improving working performance and application techniques for healthcare systems, including the integration of nanomaterials and the usage of the Internet of Things (IoT) with signal processing. Finally, the review concludes with a discussion of the future possibilities and problems for optical fiber-based wearables.


Subject(s)
Biosensing Techniques , Wearable Electronic Devices , Humans , Biosensing Techniques/methods , Optical Fibers , Pandemics , Monitoring, Physiologic/methods
19.
Biosens Bioelectron ; 255: 116237, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38537429

ABSTRACT

Scintillation-based fiber dosimeters are a powerful tool for minimally invasive localized real-time monitoring of the dose rate during Low Dose Rate (LDR) and High Dose Rate (HDR) brachytherapy (BT). This paper presents the design, fabrication, and characterization of such dosimeters, consisting of scintillating sensor tips attached to polymer optical fiber (POF). The sensor tips consist of inorganic scintillators, i.e. Gd2O2S:Tb for LDR-BT, and Y2O3:Eu+4YVO4:Eu for HDR-BT, dispersed in a polymer host. The shape and size of the tips are optimized using non-sequential ray tracing simulations towards maximizing the collection and coupling of the scintillation signal into the POF. They are then manufactured by means of a custom moulding process implemented on a commercial hot embossing machine, paving the way towards series production. Dosimetry experiments in water phantoms show that both the HDR-BT and LDR-BT sensors feature good consistency in the magnitude of the average photon count rate and that the photon count rate signal is not significantly affected by variations in sensor tip composition and geometry. Whilst individual calibration remains necessary, the proposed dosimeters show great potential for in-vivo dosimetry for brachytherapy.


Subject(s)
Biosensing Techniques , Brachytherapy , Radiation Dosimeters , Optical Fibers , Polymers
20.
PLoS One ; 19(2): e0298329, 2024.
Article in English | MEDLINE | ID: mdl-38412183

ABSTRACT

Monitoring the temperature to determine the fire source locations is essential for controlling the spontaneous combustion in the goaf. Optical fiber sensors are employed to measure the temperature distribution in the goaf. However, due to changes in the geological conditions and the influence of the falling rocks in the goaf, only sensors on the upper side of the uncompacted goaf, due to inclination and coal pillar, may remain. Unilateral sensors are located on the upper side of the goaf, while fire occurs in the center. To investigate the issue with linear unilateral sensors, a two-dimensional inverse method has been developed to determine the location of fire sources by considering heat transfer after a fire inside the goaf. The equations were theoretically solved using Green's function method to obtain the internal temperature distribution of the physical model of the goaf. Sensitivity analysis identified the most crucial parameters in the process of spontaneous heating at different temperature. The fire source location can be determined using a loop method based on the model calculations. We considered a case to validate the model. Accurately identifying the fire source location in the goaf using the unilateral sensors has an essential theoretical and practical significance for fire prevention and fighting.


Subject(s)
Coal Mining , Fires , Optical Fibers , Coal Mining/methods , Spontaneous Combustion , Coal
SELECTION OF CITATIONS
SEARCH DETAIL
...