Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.027
Filter
1.
Biomed Phys Eng Express ; 10(4)2024 May 10.
Article in English | MEDLINE | ID: mdl-38697044

ABSTRACT

Objective.The aim of this work was to develop a Phase I control chart framework for the recently proposed multivariate risk-adjusted Hotelling'sT2chart. Although this control chart alone can identify most patients receiving extreme organ-at-risk (OAR) dose, it is restricted by underlying distributional assumptions, making it sensitive to extreme observations in the sample, as is typically found in radiotherapy plan quality data such as dose-volume histogram (DVH) points. This can lead to slightly poor-quality plans that should have been identified as out-of-control (OC) to be signaled in-control (IC).Approach. We develop a robust iterative control chart framework to identify all OC patients with abnormally high OAR dose and improve them via re-optimization to achieve an IC sample prior to establishing the Phase I control chart, which can be used to monitor future treatment plans.Main Results. Eighty head-and-neck patients were used in this study. After the first iteration, P14, P67, and P68 were detected as OC for high brainstem dose, warranting re-optimization aimed to reduce brainstem dose without worsening other planning criteria. The DVH and control chart were updated after re-optimization. On the second iteration, P14, P67, and P68 were IC, but P40 was identified as OC. After re-optimizing P40's plan and updating the DVH and control chart, P40 was IC, but P14* (P14's re-optimized plan) and P62 were flagged as OC. P14* could not be re-optimized without worsening target coverage, so only P62 was re-optimized. Ultimately, a fully IC sample was achieved. Multiple iterations were needed to identify and improve all OC patients, and to establish a more robust control limit to monitor future treatment plans.Significance. The iterative procedure resulted in a fully IC sample of patients. With this sample, a more robust Phase I control chart that can monitor OAR doses of new plans was established.


Subject(s)
Organs at Risk , Quality Control , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Head and Neck Neoplasms/radiotherapy , Algorithms
2.
Technol Cancer Res Treat ; 23: 15330338241256594, 2024.
Article in English | MEDLINE | ID: mdl-38808514

ABSTRACT

Purpose: Intensity-modulated radiotherapy (IMRT) is currently the most important treatment method for nasopharyngeal carcinoma (NPC). This study aimed to enhance prediction accuracy by incorporating dose information into a deep convolutional neural network (CNN) using a multichannel input method. Methods: A target conformal plan (TCP) was created based on the maximum planning target volume (PTV). Input data included TCP dose distribution, images, target structures, and organ-at-risk (OAR) information. The role of target conformal plan dose (TCPD) was assessed by comparing the TCPD-CNN (with dose information) and NonTCPD-CNN models (without dose information) using statistical analyses with the ranked Wilcoxon test (P < .05 considered significant). Results: The TCPD-CNN model showed no statistical differences in predicted target indices, except for PTV60, where differences in the D98% indicator were < 0.5%. For OARs, there were no significant differences in predicted results, except for some small-volume or closely located OARs. On comparing TCPD-CNN and NonTCPD-CNN models, TCPD-CNN's dose-volume histograms closely resembled clinical plans with higher similarity index. Mean dose differences for target structures (predicted TCPD-CNN and NonTCPD-CNN results) were within 3% of the maximum prescription dose for both models. TCPD-CNN and NonTCPD-CNN outcomes were 67.9% and 54.2%, respectively. 3D gamma pass rates of the target structures and the entire body were higher in TCPD-CNN than in the NonTCPD-CNN models (P < .05). Additional evaluation on previously unseen volumetric modulated arc therapy plans revealed that average 3D gamma pass rates of the target structures were larger than 90%. Conclusions: This study presents a novel framework for dose distribution prediction using deep learning and multichannel input, specifically incorporating TCPD information, enhancing prediction accuracy for IMRT in NPC treatment.


Subject(s)
Deep Learning , Nasopharyngeal Carcinoma , Nasopharyngeal Neoplasms , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Nasopharyngeal Carcinoma/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Nasopharyngeal Neoplasms/radiotherapy , Organs at Risk/radiation effects , Radiometry/methods , Neural Networks, Computer
3.
J Radiat Res ; 65(3): 393-401, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38739893

ABSTRACT

Hyaluronate gel injection (HGI) in the rectovaginal septum and vesicovaginal septum is effective in the setting of high-dose-rate image-guided adaptive brachytherapy (IGABT) for cervical cancer. We aimed to retrospectively investigate optimal conditions for HGI to achieve optimal dose distribution with a minimum number of HGI. We classified 50 IGABT plans of 13 patients with cervical cancer who received IGABT both with and without HGI in the rectovaginal septum and vesicovaginal septum into the following two groups: plan with (number of plans = 32) and plan without (number of plans = 18) HGI. The irradiation dose parameters of high-risk clinical target volume (CTVHR) and organs at risk per fraction were compared between these groups. We also developed the adjusted dose score (ADS), reflecting the overall irradiation dose status for four organs at risk and CTVHR in one IGABT plan and investigated its utility in determining the application of HGI. HGI reduced the maximum dose to the most exposed 2.0 cm3 (D2.0 cm3) of the bladder while increasing the minimum dose covering 90% of CTVHR and the percentage of CTVHR receiving 100% of the prescription dose in one IGABT plan without causing any associated complications. An ADS of ≥2.60 was the optimum cut-off value to decide whether to perform HGI. In conclusion, HGI is a useful procedure for improving target dose distribution while reducing D2.0 cm3 in the bladder in a single IGABT plan. The ADS can serve as a useful indicator for the implementation of HGI.


Subject(s)
Brachytherapy , Gels , Hyaluronic Acid , Radiotherapy Dosage , Uterine Cervical Neoplasms , Humans , Female , Hyaluronic Acid/administration & dosage , Brachytherapy/methods , Uterine Cervical Neoplasms/radiotherapy , Uterine Cervical Neoplasms/diagnostic imaging , Middle Aged , Aged , Radiotherapy, Image-Guided/methods , Injections , Adult , Organs at Risk/radiation effects , Dose-Response Relationship, Radiation , Radiotherapy Planning, Computer-Assisted/methods , Time Factors , Retrospective Studies
4.
Int J Radiat Oncol Biol Phys ; 119(2): 669-680, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38760116

ABSTRACT

The Pediatric Normal Tissue Effects in the Clinic (PENTEC) consortium has made significant contributions to understanding and mitigating the adverse effects of childhood cancer therapy. This review addresses the role of diagnostic imaging in detecting, screening, and comprehending radiation therapy-related late effects in children, drawing insights from individual organ-specific PENTEC reports. We further explore how the development of imaging biomarkers for key organ systems, alongside technical advancements and translational imaging approaches, may enhance the systematic application of imaging evaluations in childhood cancer survivors. Moreover, the review critically examines knowledge gaps and identifies technical and practical limitations of existing imaging modalities in the pediatric population. Addressing these challenges may expand access to, minimize the risk of, and optimize the real-world application of, new imaging techniques. The PENTEC team envisions this document as a roadmap for the future development of imaging strategies in childhood cancer survivors, with the overarching goal of improving long-term health outcomes and quality of life for this vulnerable population.


Subject(s)
Radiation Injuries , Humans , Child , Radiation Injuries/diagnostic imaging , Cancer Survivors , Organs at Risk/diagnostic imaging , Organs at Risk/radiation effects , Neoplasms/radiotherapy , Neoplasms/diagnostic imaging , Radiotherapy/adverse effects , Diagnostic Imaging/methods
6.
Int J Radiat Oncol Biol Phys ; 119(2): 338-353, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38760115

ABSTRACT

At its very core, radiation oncology involves a trade-off between the benefits and risks of exposing tumors and normal tissue to relatively high doses of ionizing radiation. This trade-off is particularly critical in childhood cancer survivors (CCS), in whom both benefits and risks can be hugely consequential due to the long life expectancy if the primary cancer is controlled. Estimating the normal tissue-related risks of a specific radiation therapy plan in an individual patient relies on predictive mathematical modeling of empirical data on adverse events. The Pediatric Normal-Tissue Effects in the Clinic (PENTEC) collaborative network was formed to summarize and, when possible, to synthesize dose-volume-response relationships for a range of adverse events incident in CCS based on the literature. Normal-tissue clinical radiation biology in children is particularly challenging for many reasons: (1) Childhood malignancies are relatively uncommon-constituting approximately 1% of new incident cancers in the United States-and biologically heterogeneous, leading to many small series in the literature and large variability within and between series. This creates challenges in synthesizing data across series. (2) CCS are at an elevated risk for a range of adverse health events that are not specific to radiation therapy. Thus, excess relative or absolute risk compared with a reference population becomes the appropriate metric. (3) Various study designs and quantities to express risk are found in the literature, and these are summarized. (4) Adverse effects in CCS often occur 30, 50, or more years after therapy. This limits the information content of series with even very extended follow-up, and lifetime risk estimates are typically extrapolations that become dependent on the mathematical model used. (5) The long latent period means that retrospective dosimetry is required, as individual computed tomography-based radiation therapy plans gradually became available after 1980. (6) Many individual patient-level factors affect outcomes, including age at exposure, attained age, lifestyle exposures, health behaviors, other treatment modalities, dose, fractionation, and dose distribution. (7) Prospective databases with individual patient-level data and radiation dosimetry are being built and will facilitate advances in dose-volume-response modeling. We discuss these challenges and attempts to overcome them in the setting of PENTEC.


Subject(s)
Cancer Survivors , Dose-Response Relationship, Radiation , Humans , Cancer Survivors/statistics & numerical data , Child , Radiation Injuries , Organs at Risk/radiation effects , Neoplasms/radiotherapy , Risk Assessment , Neoplasms, Radiation-Induced/etiology , Radiotherapy Dosage
7.
Int J Radiat Oncol Biol Phys ; 119(2): 697-707, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38760117

ABSTRACT

The major aim of Pediatric Normal Tissue Effects in the Clinic (PENTEC) was to synthesize quantitative published dose/-volume/toxicity data in pediatric radiation therapy. Such systematic reviews are often challenging because of the lack of standardization and difficulty of reporting outcomes, clinical factors, and treatment details in journal articles. This has clinical consequences: optimization of treatment plans must balance between the risks of toxicity and local failure; counseling patients and their parents requires knowledge of the excess risks encountered after a specific treatment. Studies addressing outcomes after pediatric radiation therapy are particularly challenging because: (a) survivors may live for decades after treatment, and the latency time to toxicity can be very long; (b) children's maturation can be affected by radiation, depending on the developmental status of the organs involved at time of treatment; and (c) treatment regimens frequently involve chemotherapies, possibly modifying and adding to the toxicity of radiation. Here we discuss: basic reporting strategies to account for the actuarial nature of the complications; the reporting of modeling of abnormal development; and the need for standardized, comprehensively reported data sets and multivariate models (ie, accounting for the simultaneous effects of radiation dose, age, developmental status at time of treatment, and chemotherapy dose). We encourage the use of tools that facilitate comprehensive reporting, for example, electronic supplements for journal articles. Finally, we stress the need for clinicians to be able to trust artificial intelligence models of outcome of radiation therapy, which requires transparency, rigor, reproducibility, and comprehensive reporting. Adopting the reporting methods discussed here and in the individual PENTEC articles will increase the clinical and scientific usefulness of individual reports and associated pooled analyses.


Subject(s)
Neoplasms , Radiation Injuries , Humans , Child , Neoplasms/radiotherapy , Radiation Injuries/prevention & control , Radiation Injuries/etiology , Organs at Risk/radiation effects , Radiotherapy/adverse effects , Radiotherapy/standards , Cancer Survivors , Radiotherapy Dosage , Research Design/standards , Child, Preschool
8.
Radiat Environ Biophys ; 63(2): 297-306, 2024 May.
Article in English | MEDLINE | ID: mdl-38722389

ABSTRACT

For locally advanced cervical cancer, the standard therapeutic approach involves concomitant chemoradiation therapy, supplemented by a brachytherapy boost. Moreover, an external beam radiotherapy (RT) boost should be considered for treating gross lymph node (LN) volumes. Two boost approaches exist with Volumetric Intensity Modulated Arc Therapy (VMAT): Sequential (SEQ) and Simultaneous Integrated Boost (SIB). This study undertakes a comprehensive dosimetric and radiobiological comparison between these two boost strategies. The study encompassed ten patients who underwent RT for cervical cancer with node-positive disease. Two sets of treatment plans were generated for each patient: SIB-VMAT and SEQ-VMAT. Dosimetric as well as radiobiological parameters including tumour control probability (TCP) and normal tissue complication probability (NTCP) were compared. Both techniques were analyzed for two different levels of LN involvement - only pelvic LNs and pelvic with para-aortic LNs. Statistical analysis was performed using SPSS software version 25.0. SIB-VMAT exhibited superior target coverage, yielding improved doses to the planning target volume (PTV) and gross tumour volume (GTV). Notably, SIB-VMAT plans displayed markedly superior dose conformity. While SEQ-VMAT displayed favorable organ sparing for femoral heads, SIB-VMAT appeared as the more efficient approach for mitigating bladder and bowel doses. TCP was significantly higher with SIB-VMAT, suggesting a higher likelihood of successful tumour control. Conversely, no statistically significant difference in NTCP was observed between the two techniques. This study's findings underscore the advantages of SIB-VMAT over SEQ-VMAT in terms of improved target coverage, dose conformity, and tumour control probability. In particular, SIB-VMAT demonstrated potential benefits for cases involving para-aortic nodes. It is concluded that SIB-VMAT should be the preferred approach in all cases of locally advanced cervical cancer.


Subject(s)
Radiotherapy Dosage , Radiotherapy, Intensity-Modulated , Uterine Cervical Neoplasms , Humans , Uterine Cervical Neoplasms/radiotherapy , Uterine Cervical Neoplasms/pathology , Female , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiometry , Middle Aged , Organs at Risk/radiation effects , Lymphatic Metastasis/radiotherapy
9.
Radiat Oncol ; 19(1): 54, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702761

ABSTRACT

BACKGROUND: Stereotactic ablative body radiotherapy (SABR) is an emerging treatment alternative for patients with localized low and intermediate risk prostate cancer patients. As already explored by some authors in the context of conventional moderate hypofractionated radiotherapy, focal boost of the index lesion defined by magnetic resonance imaging (MRI) is associated with an improved biochemical outcome. The objective of this phase II trial is to determine the effectiveness (in terms of biochemical, morphological and functional control), the safety and impact on quality of life, of prostate SABR with MRI guided focal dose intensification in males with intermediate and high-risk localized prostate cancer. METHODS: Patients with intermediate and high-risk prostate cancer according to NCCN definition will be treated with SABR 36.25 Gy in 5 fractions to the whole prostate gland with MRI guided simultaneous integrated focal boost (SIB) to the index lesion (IL) up to 50 Gy in 5 fractions, using a protocol of bladder trigone and urethra sparing. Intra-fractional motion will be monitored with daily cone beam computed tomography (CBCT) and intra-fractional tracking with intraprostatic gold fiducials. Androgen deprivation therapy (ADT) will be allowed. The primary endpoint will be efficacy in terms of biochemical and local control assessed by Phoenix criteria and post-treatment MRI respectively. The secondary endpoints will encompass acute and late toxicity, quality of life (QoL) and progression-free survival. Finally, the subgroup of high-risk patients will be involved in a prospective study focused on immuno-phenotyping. DISCUSSION: To the best of our knowledge, this is the first trial to evaluate the impact of post-treatment MRI on local control among patients with intermediate and high-risk prostate cancer undergoing SABR and MRI guided focal intensification. The results of this trial will enhance our understanding of treatment focal intensification through the employment of the SABR technique within this specific patient subgroup, particularly among those with high-risk disease, and will help to clarify the significance of MRI in monitoring local responses. Hopefully will also help to design more personalized biomarker-based phase III trials in this specific context. Additionally, this trial is expected to be incorporated into a prospective radiomics study focused on localized prostate cancer treated with radiotherapy. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT05919524; Registered 17 July 2023. TRIAL SPONSOR: IRAD/SEOR (Instituto de Investigación de Oncología Radioterápica / Sociedad Española de Oncología Radioterápica). STUDY SETTING: Clinicaltrials.gov identifier: NCT05919524; Registered 17 July 2023. TRIAL STATUS: Protocol version number and date: v. 5/ 17 May-2023. Date of recruitment start: August 8, 2023. Date of recruitment completion: July 1, 2024.


Subject(s)
Prostatic Neoplasms , Radiosurgery , Radiotherapy, Image-Guided , Aged , Humans , Male , Middle Aged , Magnetic Resonance Imaging/methods , Organ Sparing Treatments/methods , Organs at Risk/radiation effects , Prospective Studies , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Prostatic Neoplasms/pathology , Quality of Life , Radiosurgery/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Urinary Bladder/radiation effects , Clinical Trials, Phase II as Topic
10.
J Cancer Res Clin Oncol ; 150(5): 280, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38802664

ABSTRACT

PROPOSE: To evaluate the advantage of the manual adaptive plans comparing to the scheduled plans, and explored clinical factors predicting patients suitable for adaptive strategy. METHODS AND MATERIALS: Eighty two patients with weekly online cone-beam computed tomography (CBCT) were enrolled. The re-CT simulation was performed after 15 fractions and a manual adaptive plan was developed if a significant deviation of the planning target volume (PTV) was found. To evaluate the dosimetric benefit, D98, homogeneity index (HI) and conformity index (CI) for the planning target volume (PTV), as well as D2cc of the bowel, bladder, sigmoid and rectum were compared between manual adaptive plans and scheduled ones. The clinical factors influencing target motion during radiotherapy were analyzed by chi-square test and logistic regression analysis. RESULTS: The CI and HI of the manual adaptive plans were significantly superior to the scheduled ones (P = 0.0002, 0.003, respectively), demonstrating a better dose coverage of the target volume. Compared to the scheduled plans, D98 of the manual adaptive plans increased by 3.3% (P = 0.0002), the average of D2cc to the rectum, bladder decreased 0.358 Gy (P = 0.000034) and 0.240 Gy (P = 0.03), respectively. In addition, the chi-square test demonstrated that age, primary tumor volume, and parametrial infiltration were the clinical factors influencing target motion during radiotherapy. Multivariate analysis further identified the large tumor volume (≥ 50cm3, OR = 3.254, P = 0.039) and parametrial infiltration (OR = 3.376, P = 0.018) as the independent risk factors. CONCLUSION: We found the most significant organ motion happened after 15 fractions during treatment. The manual adaptive plans improved the dose coverage and decreased the OAR doses. Patients with bulky mass or with parametrial infiltration were highly suggested to adaptive strategy during definitive radiotherapy due to the significant organ motion.


Subject(s)
Cone-Beam Computed Tomography , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Uterine Cervical Neoplasms , Humans , Female , Radiotherapy Planning, Computer-Assisted/methods , Uterine Cervical Neoplasms/radiotherapy , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/pathology , Middle Aged , Aged , Adult , Cone-Beam Computed Tomography/methods , Radiometry/methods , Organs at Risk/radiation effects , Aged, 80 and over
11.
Phys Med ; 121: 103369, 2024 May.
Article in English | MEDLINE | ID: mdl-38669811

ABSTRACT

PURPOSE: In radiotherapy it is often necessary to transfer a patient's DICOM (Digital Imaging and COmmunications in Medicine) dataset from one system to another for re-treatment, plan-summation or registration purposes. The aim of the study is to evaluate effects of dataset transfer between treatment planning systems. MATERIALS AND METHODS: Twenty-five patients treated in a 0.35T MR-Linac (MRidian, ViewRay) for locally-advanced pancreatic cancer were enrolled. For each patient, a nominal dose distribution was optimized on the planning MRI. Each plan was daily re-optimized if needed to match the anatomy and exported from MRIdian-TPS (ViewRay Inc.) to Eclipse-TPS (Siemens-Varian). A comparison between the two TPSs was performed considering the PTV and OARs volumes (cc), as well as dose coverages and clinical constraints. RESULTS: From the twenty-five enrolled patients, 139 plans were included in the data comparison. The median values of percentage PTV volume variation are 10.8 % for each fraction, while percentage differences of PTV coverage have a mean value of -1.4 %. The median values of the percentage OARs volume variation are 16.0 %, 7.0 %, 10.4 % and 8.5 % for duodenum, stomach, small and large bowel, respectively. The percentage variations of the dose constraints are 41.0 %, 52.7 % and 49.8 % for duodenum, stomach and small bowel, respectively. CONCLUSIONS: This study has demonstrated a non-negligible variation in size and dosimetric parameters when datasets are transferred between TPSs. Such variations should be clinically considered. Investigations are focused on DICOM structure algorithm employed by the TPSs during the transfer to understand the cause of such variations.


Subject(s)
Pancreatic Neoplasms , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy Planning, Computer-Assisted/methods , Humans , Pancreatic Neoplasms/radiotherapy , Pancreatic Neoplasms/diagnostic imaging , Organs at Risk/radiation effects , Magnetic Resonance Imaging
12.
Phys Med ; 121: 103346, 2024 May.
Article in English | MEDLINE | ID: mdl-38608421

ABSTRACT

Partial breast irradiation for the treatment of early-stage breast cancer patients can be performed by means of Intra Operative electron Radiation Therapy (IOeRT). One of the main limitations of this technique is the absence of a treatment planning system (TPS) that could greatly help in ensuring a proper coverage of the target volume during irradiation. An IOeRT TPS has been developed using a fast Monte Carlo (MC) and an ultrasound imaging system to provide the best irradiation strategy (electron beam energy, applicator position and bevel angle) and to facilitate the optimisation of dose prescription and delivery to the target volume while maximising the organs at risk sparing. The study has been performed in silico, exploiting MC simulations of a breast cancer treatment. Ultrasound-based input has been used to compute the absorbed dose maps in different irradiation strategies and a quantitative comparison between the different options was carried out using Dose Volume Histograms. The system was capable of exploring different beam energies and applicator positions in few minutes, identifying the best strategy with an overall computation time that was found to be completely compatible with clinical implementation. The systematic uncertainty related to tissue deformation during treatment delivery with respect to imaging acquisition was taken into account. The potential and feasibility of a GPU based full MC TPS implementation of IOeRT breast cancer treatments has been demonstrated in-silico. This long awaited tool will greatly improve the treatment safety and efficacy, overcoming the limits identified within the clinical trials carried out so far.


Subject(s)
Breast Neoplasms , Monte Carlo Method , Radiotherapy Planning, Computer-Assisted , Breast Neoplasms/radiotherapy , Breast Neoplasms/diagnostic imaging , Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Electrons/therapeutic use , Time Factors , Computer Graphics , Female , Organs at Risk/radiation effects
13.
Radiat Oncol ; 19(1): 53, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38689338

ABSTRACT

PURPOSE: The number of older adults with head and neck squamous cell carcinoma (HNSCC) is continuously increasing. Older HNSCC patients may be more vulnerable to radiotherapy-related toxicities, so that extrapolation of available normal tissue complication probability (NTCP) models to this population may not be appropriate. Hence, we aimed to investigate the correlation between organ at risk (OAR) doses and chronic toxicities in older patients with HNSCC undergoing definitive radiotherapy. METHODS: Patients treated with definitive radiotherapy, either alone or with concomitant systemic treatment, between 2009 and 2019 in a large tertiary cancer center were eligible for this analysis. OARs were contoured based on international consensus guidelines, and EQD2 doses using α/ß values of 3 Gy for late effects were calculated based on the radiation treatment plans. Treatment-related toxicities were graded according to Common Terminology Criteria for Adverse Events version 5.0. Logistic regression analyses were carried out, and NTCP models were developed and internally validated using the bootstrapping method. RESULTS: A total of 180 patients with a median age of 73 years fulfilled the inclusion criteria and were analyzed. Seventy-three patients developed chronic moderate xerostomia (grade 2), 34 moderate dysgeusia (grade 2), and 59 moderate-to-severe (grade 2-3) dysphagia after definitive radiotherapy. The soft palate dose was significantly associated with all analyzed toxicities (xerostomia: OR = 1.028, dysgeusia: OR = 1.022, dysphagia: OR = 1.027) in the multivariable regression. The superior pharyngeal constrictor muscle was also significantly related to chronic dysphagia (OR = 1.030). Consecutively developed and internally validated NTCP models were predictive for the analyzed toxicities (optimism-corrected AUCs after bootstrapping: AUCxerostomia=0.64, AUCdysgeusia=0.60, AUCdysphagia=0.64). CONCLUSIONS: Our data suggest that the dose to the soft palate is associated with chronic moderate xerostomia, moderate dysgeusia and moderate-to-severe dysphagia in older HNSCC patients undergoing definitive radiotherapy. If validated in external studies, efforts should be undertaken to reduce the soft palate dose in these patients.


Subject(s)
Head and Neck Neoplasms , Organs at Risk , Palate, Soft , Radiation Injuries , Radiotherapy Dosage , Squamous Cell Carcinoma of Head and Neck , Humans , Aged , Female , Male , Head and Neck Neoplasms/radiotherapy , Organs at Risk/radiation effects , Palate, Soft/radiation effects , Radiation Injuries/etiology , Aged, 80 and over , Middle Aged , Squamous Cell Carcinoma of Head and Neck/radiotherapy , Retrospective Studies , Radiotherapy Planning, Computer-Assisted/methods
14.
Acta Oncol ; 63: 240-247, 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38682458

ABSTRACT

BACKGROUND AND PURPOSE: Doses to the coronary arteries in breast cancer (BC) radiotherapy (RT) have been suggested to be a risk predictor of long-term cardiac toxicity after BC treatment. We investigated the dose-risk relationships between near maximum doses (Dmax) to the right coronary artery (RCA) and left anterior descending coronary artery (LAD) and ischemic heart disease (IHD) mortality after BC RT. PATIENTS AND METHODS: In a cohort of 2,813 women diagnosed with BC between 1958 and 1992 with a follow-up of at least 10 years, we identified 134 cases of death due to IHD 10-19 years after BC diagnosis. For each case, one control was selected within the cohort matched for age at diagnosis. 3D-volume and 3D-dose reconstructions were obtained from individual RT charts. We estimated the Dmax to the RCA and the LAD and the mean heart dose (MHD). We performed conditional logistic regression analysis comparing piecewise spline transformation and simple linear modeling for best fit. RESULTS: There was a linear dose-risk relationship for both the Dmax to the RCA (odds ratio [OR]/Gray [Gy] 1.03 [1.01-1.05]) and the LAD (OR/Gy 1.04 [1.02-1.06]) in a multivariable model. For MHD there was a linear dose-risk relationship (1,14 OR/Gy [1.08-1.19]. For all relationships, simple linear modelling was superior to spline transformations. INTERPRETATION: Doses to both the RCA and LAD are independent risk predictors of long-term cardiotoxicity after RT for BC In addition to the LAD, the RCA should be regarded as an organ at risk in RT planning.


Subject(s)
Breast Neoplasms , Coronary Vessels , Myocardial Ischemia , Humans , Female , Breast Neoplasms/radiotherapy , Breast Neoplasms/mortality , Case-Control Studies , Middle Aged , Coronary Vessels/radiation effects , Coronary Vessels/pathology , Myocardial Ischemia/etiology , Myocardial Ischemia/mortality , Aged , Adult , Radiation Injuries/etiology , Radiation Injuries/epidemiology , Radiation Injuries/mortality , Radiotherapy Dosage , Dose-Response Relationship, Radiation , Organs at Risk/radiation effects , Follow-Up Studies , Cohort Studies
15.
J Egypt Natl Canc Inst ; 36(1): 11, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38584227

ABSTRACT

BACKGROUND: The moderate deep inspiratory breath hold (mDIBH) is a modality famed for cardiac sparing. Prospective studies based on this are few from the eastern part of the world and India. We intend to compare the dosimetry between mDIBH and free-breathing (FB) plans. METHODS: Thirty-two locally advanced left breast cancer patients were taken up for the study. All patients received a dose of 50 Gy in 25 fractions to the chest wall/intact breast, followed by a 10-Gy boost to the lumpectomy cavity in the case of breast conservation surgery. All the patients were treated in mDIBH using active breath coordinator (ABC). The data from the two dose volume histograms were compared regarding plan quality and the doses received by the organs at risk. Paired t-test was used for data analysis. RESULTS: The dose received by the heart in terms of V5, V10, and V30 (4.55% vs 8.39%) and mean dose (4.73 Gy vs 6.74 Gy) were statistically significant in the ABC group than that in the FB group (all p-values < 0.001). Also, the dose received by the LADA in terms of V30 (19.32% vs 24.87%) and mean dose (32.99 Gy vs 46.65 Gy) were significantly less in the ABC group. The mean treatment time for the ABC group was 20 min, while that for the free-breathing group was 10 min. CONCLUSIONS: Incorporating ABC-mDIBH for left-sided breast cancer radiotherapy significantly reduces the doses received by the heart, LADA, and left and right lung, with no compromise in plan quality but with an increase in treatment time.


Subject(s)
Breast Neoplasms , Unilateral Breast Neoplasms , Humans , Female , Breath Holding , Unilateral Breast Neoplasms/radiotherapy , Breast Neoplasms/radiotherapy , Prospective Studies , Heart , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Organs at Risk
16.
Technol Cancer Res Treat ; 23: 15330338241242654, 2024.
Article in English | MEDLINE | ID: mdl-38584413

ABSTRACT

Purpose: Deep learning (DL) is widely used in dose prediction for radiation oncology, multiple DL techniques comparison is often lacking in the literature. To compare the performance of 4 state-of-the-art DL models in predicting the voxel-level dose distribution for cervical cancer volumetric modulated arc therapy (VMAT). Methods and Materials: A total of 261 patients' plans for cervical cancer were retrieved in this retrospective study. A three-channel feature map, consisting of a planning target volume (PTV) mask, organs at risk (OARs) mask, and CT image was fed into the three-dimensional (3D) U-Net and its 3 variants models. The data set was randomly divided into 80% as training-validation and 20% as testing set, respectively. The model performance was evaluated on the 52 testing patients by comparing the generated dose distributions against the clinical approved ground truth (GT) using mean absolute error (MAE), dose map difference (GT-predicted), clinical dosimetric indices, and dice similarity coefficients (DSC). Results: The 3D U-Net and its 3 variants DL models exhibited promising performance with a maximum MAE within the PTV 0.83% ± 0.67% in the UNETR model. The maximum MAE among the OARs is the left femoral head, which reached 6.95% ± 6.55%. For the body, the maximum MAE was observed in UNETR, which is 1.19 ± 0.86%, and the minimum MAE was 0.94 ± 0.85% for 3D U-Net. The average error of the Dmean difference for different OARs is within 2.5 Gy. The average error of V40 difference for the bladder and rectum is about 5%. The mean DSC under different isodose volumes was above 90%. Conclusions: DL models can predict the voxel-level dose distribution accurately for cervical cancer VMAT treatment plans. All models demonstrated almost analogous performance for voxel-wise dose prediction maps. Considering all voxels within the body, 3D U-Net showed the best performance. The state-of-the-art DL models are of great significance for further clinical applications of cervical cancer VMAT.


Subject(s)
Deep Learning , Radiotherapy, Intensity-Modulated , Uterine Cervical Neoplasms , Female , Humans , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/radiotherapy , Retrospective Studies , Organs at Risk
17.
J Appl Clin Med Phys ; 25(5): e14345, 2024 May.
Article in English | MEDLINE | ID: mdl-38664894

ABSTRACT

PURPOSE: To establish the clinical applicability of deep-learning organ-at-risk autocontouring models (DL-AC) for brain radiotherapy. The dosimetric impact of contour editing, prior to model training, on performance was evaluated for both CT and MRI-based models. The correlation between geometric and dosimetric measures was also investigated to establish whether dosimetric assessment is required for clinical validation. METHOD: CT and MRI-based deep learning autosegmentation models were trained using edited and unedited clinical contours. Autosegmentations were dosimetrically compared to gold standard contours for a test cohort. D1%, D5%, D50%, and maximum dose were used as clinically relevant dosimetric measures. The statistical significance of dosimetric differences between the gold standard and autocontours was established using paired Student's t-tests. Clinically significant cases were identified via dosimetric headroom to the OAR tolerance. Pearson's Correlations were used to investigate the relationship between geometric measures and absolute percentage dose changes for each autosegmentation model. RESULTS: Except for the right orbit, when delineated using MRI models, the dosimetric statistical analysis revealed no superior model in terms of the dosimetric accuracy between the CT DL-AC models or between the MRI DL-AC for any investigated brain OARs. The number of patients where the clinical significance threshold was exceeded was higher for the optic chiasm D1% than other OARs, for all autosegmentation models. A weak correlation was consistently observed between the outcomes of dosimetric and geometric evaluations. CONCLUSIONS: Editing contours before training the DL-AC model had no significant impact on dosimetry. The geometric test metrics were inadequate to estimate the impact of contour inaccuracies on dose. Accordingly, dosimetric analysis is needed to evaluate the clinical applicability of DL-AC models in the brain.


Subject(s)
Brain Neoplasms , Deep Learning , Magnetic Resonance Imaging , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Tomography, X-Ray Computed , Humans , Organs at Risk/radiation effects , Magnetic Resonance Imaging/methods , Tomography, X-Ray Computed/methods , Brain Neoplasms/radiotherapy , Brain Neoplasms/diagnostic imaging , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Radiometry/methods , Image Processing, Computer-Assisted/methods
18.
J Appl Clin Med Phys ; 25(5): e14366, 2024 May.
Article in English | MEDLINE | ID: mdl-38669190

ABSTRACT

PURPOSE: Skin collimation is a useful tool in electron beam therapy (EBT) to decrease the penumbra at the field edge and minimize dose to nearby superficial organs at risk (OARs), but manually fabricating these collimation devices in the clinic to conform to the patient's anatomy can be a difficult and time intensive process. This work compares two types of patient-specific skin collimation (in-house 3D printed and vendor-provided machined brass) using clinically relevant metrics. METHODS: Attenuation measurements were performed to determine the thickness of each material needed to adequately shield both 6 and 9 MeV electron beams. Relative and absolute dose planes at various depths were measured using radiochromic film to compare the surface dose, flatness, and penumbra of the different skin collimation materials. RESULTS: Clinically acceptable thicknesses of each material were determined for both 6 and 9 MeV electron beams. Field width, flatness, and penumbra results between the two systems were very similar and significantly improved compared to measurements performed with no surface collimation. CONCLUSION: Both skin collimation methods investigated in this work generate sharp penumbras at the field edge and can minimize dose to superficial OARs compared to treatment fields with no surface collimation. The benefits of skin collimation are greatest for lower energy electron beams, and the benefits decrease as the measurement depth increases. Using bolus with skin collimation is recommended to avoid surface dose enhancement seen with collimators placed on the skin surface. Ultimately, the appropriate choice of material will depend on the desire to create these devices in-house or outsource the fabrication to a vendor.


Subject(s)
Electrons , Organs at Risk , Printing, Three-Dimensional , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Skin , Humans , Electrons/therapeutic use , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk/radiation effects , Skin/radiation effects , Phantoms, Imaging , Neoplasms/radiotherapy , Particle Accelerators/instrumentation
19.
Asian Pac J Cancer Prev ; 25(4): 1383-1390, 2024 04 01.
Article in English | MEDLINE | ID: mdl-38680000

ABSTRACT

BACKGROUND: The study aims to investigate potential dosimetric benefits between non-coplanar and coplanar beam arrangements of Volumetric-Modulated Arc Therapy (VMAT) plans for liver stereotactic body radiotherapy (SBRT). METHODS: Thirteen patients who had undergone liver SBRT treatment in our department were chosen retrospectively for the study. Two sets of SBRT-VMAT plans namely, non-coplanar (NC-VMAT) and Coplanar (C-VMAT) were generated in Monaco(v5.11) planning system for Elekta Versa HD Linac using unflatten 6MV photon. The NC-VMAT plans were created by two/three non-coplanar partial arcs with couch rotation of ±150 and had an arc span of 1300 to 1600 whereas the C-VMAT plans consisted of a full arc. Both plans were compared by statistically analyzing various dosimetric and technical parameters. RESULTS: There is no statistically significant difference observed between the C-VMAT and NC-VMAT plans for planning target volume (PTV) coverage. However, the spine dose (D1cc) was much less in the NC-VMAT plan compared to the C-VMAT plan, with mean values of 6.127 ± 3.08Gy and 9.058 ± 4.76Gy, respectively (p-value=0.002). The low dose spillage to the healthy tissue was compared by the volume receiving 5Gy (V5Gy) and 10Gy (V10Gy). V5Gy of the NC-VMAT plan was 2399.23±1870.76cc while that of C-VMAT plans was 2835.36±1930.20cc with the p-value <0.001. Moreover, the monitor units(MU) were less with NC-VMAT than with C-VMAT SBRT plans (p=0.015). CONCLUSION: The plan quality of NC-VMAT plans was favorable compared to C-VMAT plans for liver SBRT especially in reducing spine dose, low dose spillage to healthy tissue, and MU.


Subject(s)
Liver Neoplasms , Organs at Risk , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Liver Neoplasms/radiotherapy , Liver Neoplasms/surgery , Retrospective Studies , Organs at Risk/radiation effects , Prognosis , Male , Female , Follow-Up Studies , Aged , Middle Aged
20.
Phys Med Biol ; 69(11)2024 May 20.
Article in English | MEDLINE | ID: mdl-38688290

ABSTRACT

Objective. Lowering treatment costs and improving treatment quality are two primary goals for next-generation proton therapy (PT) facilities. This work will design a compact large momentum acceptance superconducting (LMA-SC) gantry beamline to reduce the footprint and expense of the PT facilities, with a novel mixed-size spot scanning method to improve the sparing of organs at risk (OAR).Approach. For the LMA-SC gantry beamline, the movable energy slit is placed in the middle of the last achromatic bending section, and the beam momentum spread of delivered spots can be easily changed during the treatment. Simultaneously, changing the collimator size can provide spots with various lateral spot sizes. Based on the provided large-size and small-size spot models, the treatment planning with mixed spot scanning is optimized: the interior of the target is irradiated with large-size spots (to cover the uniform-dose interior efficiently), while the peripheral of the target is irradiated with small-size spots (to shape the sharp dose falloff at the peripheral accurately).Main results. The treatment plan with mixed-size spot scanning was evaluated and compared with small and large-size spot scanning for thirteen clinical prostate cases. The mixed-size spot plan had superior target dose homogeneities, better protection of OAR, and better plan robustness than the large-size spot plan. Compared to the small-size spot plan, the mixed-size spot plan had comparable plan quality, better plan robustness, and reduced plan delivery time from 65.9 to 40.0 s.Significance. The compact LMA-SC gantry beamline is proposed with mixed-size spot scanning, with demonstrated footprint reduction and improved plan quality compared to the conventional spot scanning method.


Subject(s)
Prostatic Neoplasms , Proton Therapy , Radiotherapy Planning, Computer-Assisted , Proton Therapy/instrumentation , Proton Therapy/methods , Humans , Radiotherapy Planning, Computer-Assisted/methods , Prostatic Neoplasms/radiotherapy , Male , Superconductivity , Radiotherapy Dosage , Organs at Risk/radiation effects
SELECTION OF CITATIONS