Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.834
Filter
1.
BMC Oral Health ; 24(1): 650, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38824555

ABSTRACT

BACKGROUND: The formation of white spots, which represent early carious lesions, is a major issue with fixed orthodontics. The addition of remineralizing agents to orthodontic adhesives may prevent the formation of white spots. The aim of this study was to produce a composite orthodontic adhesive combined with nano-bioactive glass-silver (nBG@Ag) for bracket bonding to enamel and to investigate its cytotoxicity, antimicrobial activity, remineralization capability, and bond strength. METHODS: nBG@Ag was synthesized using the sol-gel method, and characterized using transmission electron microscopy (TEM), X-ray diffraction (XRD), and Fourier-transform infrared spectroscopy with an attenuated total reflectance attachment (ATR-FTIR). The cytotoxicity test (MTT) and antimicrobial activity of adhesives containing 1%, 3%, and 5% (wt/wt) nBG@Ag were evaluated, and the shear bond strength of the adhesives was measured using a universal testing machine. Remineralization was assessed through microhardness testing with a Vickers microhardness tester and scanning electron microscopy (SEM). Statistical analyses were conducted using the Shapiro-Wilk test, Levene test, one-way ANOVA, Robust-Welch test, Tukey HSD method, and two-way ANOVA. RESULTS: The biocompatibility of the adhesives was found to be high, as confirmed by the lack of significant differences in the cytotoxicity between the sample and control groups. Discs made from composites containing nBG@Ag exhibited a significant reduction in the growth of Streptococcus mutans (p < 0.05), and the antibacterial activity increased with higher percentages of nBG@Ag. The shear bond strength of the adhesives decreased significantly (p < 0.001) after the addition of nanoparticles, but it remained above the recommended value. The addition of nBG@Ag showed improvement in the microhardness of the teeth, although the differences in microhardness between the study groups were not statistically significant. The formation of hydroxyapatite deposits on the tooth surface was confirmed through SEM and energy-dispersive X-ray spectroscopy (EDX). CONCLUSION: Adding nBG@Ag to orthodontic adhesives can be an effective approach to enhance antimicrobial activity and reduce enamel demineralization around the orthodontic brackets, without compromising biocompatibility and bond strength.


Subject(s)
Anti-Bacterial Agents , Dental Cements , Orthodontic Brackets , Silver , Tooth Remineralization , Anti-Bacterial Agents/pharmacology , Silver/pharmacology , Tooth Remineralization/methods , Dental Cements/pharmacology , Materials Testing , Nanostructures/therapeutic use , Streptococcus mutans/drug effects , Microscopy, Electron, Scanning , Spectroscopy, Fourier Transform Infrared , X-Ray Diffraction , Glass/chemistry , Microscopy, Electron, Transmission , Ceramics , Humans , Composite Resins/pharmacology , Composite Resins/chemistry , Shear Strength , Hardness , Dental Bonding/methods , Dental Enamel/drug effects
2.
IET Nanobiotechnol ; 2024: 4391833, 2024.
Article in English | MEDLINE | ID: mdl-38863970

ABSTRACT

The massive growth of various microorganisms on the orthodontic bracket can form plaques and cause diseases. A novel amine-terminated hyperbranched zirconium-polysiloxane (HPZP) antimicrobial coating was developed for an orthodontic stainless steel tank (SST). After synthesizing HPZP and HPZP-Ag coatings, their structures were characterized by nuclear magnetic resonance spectroscopy, scanning electron microscopy, thickness measurement, contact angle detection, mechanical stability testing, and corrosion testing. The cell toxicity of the two coatings to human gingival fibroblasts (hGFs) and human oral keratinocytes (hOKs) was detected by cell counting kit eight assays, and SST, HPZP@SST, and HPZP-Ag@SST were cocultured with Staphylococcus aureus, Escherichia coli, and Streptococcus mutans for 24 hr to detect the antibacterial properties of the coatings, respectively. The results show that the coatings are about 10 µm, and the water contact angle of HPZP coating is significantly higher than that of HPZP-Ag coating (P < 0.01). Both coatings can be uniformly and densely distributed on SST and have good mechanical stability and corrosion resistance. The cell counting test showed that HPZP coating and HPZP-Ag coating were less toxic to cells compared with SST, and the toxicity of HPZP-Ag coating was greater than that of HPZP coating, with the cell survival rate greater than 80% after 72 hr cocultured with hGFs and hOKs. The antibacterial test showed that the number of bacteria on the surface of different materials was ranked from small to large: HPZP@SST < HPZP-Ag@SST < SST and 800 µg/mL HPZP@SST showed a better bactericidal ability than 400 µg/mL after cocultured with S. aureus, E. coli, and S. mutans, respectively (all P < 0.05). The results showed that HPZP coating had a better effect than HPZP-Ag coating, with effective antibacterial and biocompatible properties, which had the potential to be applied in orthodontic process management.


Subject(s)
Anti-Bacterial Agents , Coated Materials, Biocompatible , Orthodontic Brackets , Siloxanes , Stainless Steel , Zirconium , Stainless Steel/chemistry , Stainless Steel/pharmacology , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Humans , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Orthodontic Brackets/microbiology , Zirconium/chemistry , Zirconium/pharmacology , Siloxanes/chemistry , Siloxanes/pharmacology , Fibroblasts/drug effects , Materials Testing , Amines/chemistry , Amines/pharmacology , Staphylococcus aureus/drug effects , Surface Properties , Escherichia coli/drug effects , Keratinocytes/drug effects , Cell Survival/drug effects , Gingiva/cytology , Gingiva/drug effects
3.
Lasers Med Sci ; 39(1): 156, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38869676

ABSTRACT

The risk of enamel deterioration that frequently coexists with debonding of orthodontic teeth brackets elevates the mandate for finding an optimum approach for debonding them without harmful effects. This in-vitro study is intended to compare the effects of two different laser modes (scanning and circular) and a conventional method on the enamel surface after debonding orthodontic brackets. 66 extracted premolars were assigned into 3 groups. After that, light-cure composite resin was used to attach the ceramic brackets to the teeth. Amongst the test groups, Group I: specimens that were debonded using conventional debonding using pliers; Group 2: specimens that were debonded using Er, Cr: YSGG laser applications using the circular motion method; and Group 3: specimens that were debonded using Er, Cr: YSGG laser applications using the scanning motion method. Adhesive Remnant Index (ARI) assessment, intra-pulpal temperature increase, enamel surface roughness after polishing, and assessment of the microstructure of enamel were carried out with scanning electron microscopy. The gathered information was examined statistically. The conventional debonding method had a significantly higher proportion of adhesive remnant index (ARI) scores of 2 and 3 in comparison to the circular (p < .004) and scanning laser groups (p < .001). There was no significant difference in ARI scores between the circular and scanning laser groups (p > .05). Moreover, the circular and scanning laser debonding methods resulted in a significantly higher proportion of Enamel Surface Roughness (ESR) scores of 0 and a lower proportion of ESR scores of 3 compared to the conventional technique group (p < .001). However, there was no significant difference in ESR scores between the circular and scanning laser methods (p = .945). Lastly, the average intra-pulpal temperature was significantly higher in the circular laser group (1.9 ± 0.5 ) compared to the scanning laser group (0.9 ± 0.2) with p < .001. Er, Cr: YSGG laser irradiation is a tool that shows promise for debonding ceramic brackets with minimal harm to the enamel surface. The scanning laser technique is more desirable due to the lower intra-pulpal temperature increase.


Subject(s)
Ceramics , Dental Debonding , Dental Enamel , Lasers, Solid-State , Orthodontic Brackets , Surface Properties , Humans , Dental Enamel/radiation effects , Dental Debonding/methods , Dental Debonding/instrumentation , Lasers, Solid-State/therapeutic use , In Vitro Techniques , Microscopy, Electron, Scanning , Bicuspid
4.
BMC Oral Health ; 24(1): 680, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38867181

ABSTRACT

BACKGROUND: To investigate the effect of a 50% ascorbic acid with 50% citric acid solution on the immediate shear bond strength (SBS) of metallic brackets after tooth bleaching. The enamel etching pattern and the required quantity of these combined acids as antioxidants following 35% hydrogen peroxide (HP) bleaching were also determined. METHODS: The stability of the solution at room temperature was assessed at various time intervals. Fifty teeth were randomly divided into five groups: non-bleached (G1), bleached then acid etched (G2), bleached followed by a 10-minute treatment with 10% sodium ascorbate and acid etched (G3), 5-minute treatment with 50% ascorbic acid (G4), and 5-minute treatment with a combination of 50% ascorbic acid and 50% citric acid (G5). Groups G2, G3, G4 and G5 were bleached by 35% HP gel for a total of 32 min. Acid etching in groups G1, G2, and G3 was performed using 37% phosphoric acid (Ormco®, Orange, CA, USA) for 15 s. In all groups, metal brackets were immediately bonded using Transbond™ XT primer and Transbond™ PLUS adhesive, with light curing for 40 s. The SBS was tested with a universal testing machine, and statistical analysis was conducted using one-way ANOVA followed by Tukey's HSD test. The level of significance was set at p < 0.05 for all statistical tests. RESULTS: Stability tests demonstrated that the combined acids remained effective for up to 21 days. Group G5 significantly increased the SBS of bleached teeth to the level of G1 (p < 0.05), while G3 did not achieve the same increase in SBS (p > 0.05). SEM analysis revealed enamel etching patterns similar to those of both control groups (G1 and G2). Kinetic studies at 6 min indicated that the antioxidation in G5 reacted 0.2 mmole lower than in G3 and G4. CONCLUSION: 5-minute application of the combined acids enhanced the SBS of bleached teeth comparable to unbleached teeth. The combined acids remain stable over two weeks, presenting a time-efficient, single-step solution for antioxidant application and enamel etching in orthodontic bracket bonding.


Subject(s)
Ascorbic Acid , Citric Acid , Dental Bonding , Dental Enamel , Orthodontic Brackets , Shear Strength , Tooth Bleaching , Ascorbic Acid/pharmacology , Citric Acid/pharmacology , Citric Acid/chemistry , Tooth Bleaching/methods , Humans , Pilot Projects , Dental Enamel/drug effects , Dental Bonding/methods , Acid Etching, Dental , Antioxidants/pharmacology , Surface Properties , Time Factors , Hydrogen Peroxide/chemistry , Tooth Bleaching Agents/chemistry , Phosphoric Acids , Dental Stress Analysis
5.
Med Sci Monit ; 30: e944255, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38843112

ABSTRACT

Orthodontic treatments, while essential for achieving optimal oral health, present challenges in infection control due to the propensity for bacterial adhesion and biofilm formation on orthodontic appliances. Silver-coated orthodontic materials have emerged as a promising solution, leveraging the potent antimicrobial properties of silver nanoparticles (AgNPs). Antibacterial coatings are used in orthodontics to prevent the formation of bacterial biofilms. This systematic review evaluated the literature on antimicrobial silver coatings on fixed orthodontic appliances, including archwires, brackets, and microimplants. Two evaluators, working independently, rigorously conducted a comprehensive search of various databases, including PubMed, PubMed Central, Embase, Scopus and Web of Science. This systematic review comprehensively examined in vitro studies investigating the antimicrobial efficacy of silver-coated orthodontic archwires, brackets, and microimplants. The review registered in PROSPERO CRD42024509189 synthesized findings from 18 diverse studies, revealing consistent and significant reductions in bacterial adhesion, biofilm formation, and colony counts with the incorporation of AgNPs. Key studies demonstrated the effectiveness of silver-coated archwires and brackets against common oral bacteria, such as Streptococcus mutans and Staphylococcus aureus. Microimplants coated with AgNPs also exhibited notable antimicrobial activity against a range of microorganisms. The systematic review revealed potential mechanisms underlying these antimicrobial effects, highlighted implications for infection prevention in orthodontic practice, and suggested future research avenues. Despite some study heterogeneity and limitations, the collective evidence supports the potential of silver-coated orthodontic materials in mitigating bacterial complications, emphasizing their relevance in advancing infection control measures in orthodontics.


Subject(s)
Biofilms , Metal Nanoparticles , Orthodontic Brackets , Silver , Silver/pharmacology , Humans , Biofilms/drug effects , Orthodontic Brackets/microbiology , Orthodontic Wires/microbiology , Orthodontic Appliances, Fixed , Anti-Infective Agents/pharmacology , Coated Materials, Biocompatible/pharmacology , Anti-Bacterial Agents/pharmacology , Streptococcus mutans/drug effects , Bacterial Adhesion/drug effects , Staphylococcus aureus/drug effects
6.
Prog Orthod ; 25(1): 24, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38880839

ABSTRACT

INTRODUCTION: Metallic and elastomeric ligatures are widely used in orthodontics to secure the archwire within the bracket slots, but elastomeric ligatures have traditionally been associated with increased microbial colonization, which could adversely affect periodontal health. AIM: This systematic review compares the periodontal effects of elastomeric and steel ligatures used for orthodontic fixed appliances. METHODS: Unrestricted literature search of 7 databases (MEDLINE, Scopus, Web of Science, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, and Virtual Health Library) up to July 2023 were performed for randomized / non-randomized clinical studies on humans comparing the two ligation methods during fixed-appliance therapy. After duplicate study selection, data extraction, and risk-of-bias assessment with the Risk of Bias (RoB) 2 or the Risk Of Bias In Non-randomized Studies - of Interventions (ROBINS-I) tool, random-effects meta-analyses of Mean Differences (MD) or Standardized Mean Differences (SMD) and their 95% confidence intervals (CIs) were carried out, followed by assessment of certainty of existing evidence with the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) approach. RESULTS: A total of 11 studies (3 randomized / 8 non-randomized) with 354 patients (mean age 14.7 years and 42% male) were included. No statistically significant differences were seen for plaque index (5 studies; SMD = 0.48; 95% CI = -0.03 to 1.00; P = 0.07), gingival index (2 studies; MD = 0.01; 95% CI = -0.14 to 0.16; P = 0.89), probing pocket depth (2 studies; MD = 0; 95% CI = -0.17 to 0.16; P = 0.97), or Streptococcus mutans counts (4 studies; SMD = 0.40; 95% CI=-0.41 to 1.20; P = 0.21). Elastomeric ligatures were associated with moderately increased total bacterial load (3 studies; SMD = 0.43; 95% CI = 0.10 to 0.76; P = 0.03). Confidence in these estimates was low in all instances due to the inclusion of non-randomized studies with high risk of bias. CONCLUSIONS: Existing low quality evidence indicates that ligature method does not seem to influence the periodontal health during fixed treatment, even if elastomeric ligatures are associated with a moderate increase of bacterial load. REGISTRATION: PROSPERO (CRD42023444383).


Subject(s)
Elastomers , Orthodontic Appliances, Fixed , Humans , Steel , Periodontal Index , Orthodontic Brackets , Ligation
7.
Biomed Res Int ; 2024: 7457900, 2024.
Article in English | MEDLINE | ID: mdl-38884017

ABSTRACT

Objective: To evaluate the enamel bonding ability and orthodontic adhesive resin degree of conversion using the experimental bracket design. Material and Methods. Thirteen bovine teeth were used in the study. The experimental bracket was modified with a translucent region in the center of its body. After enamel etching, Orthocem orthodontic adhesive (FGM, Joinville, Brazil) was applied on the bracket base for bonding. The groups were divided as follows (n = 10 per group): (1) control (CB) with standard brackets and (2) spot bracket (SB) with experimental brackets featuring a 0.8 mm translucent region at the center using carbide bur. Shear bond strength (SBS) was evaluated after 24 hours in a universal testing machine and adhesive remnant index (ARI). The degree of conversion (DC) was analyzed using Raman spectroscopy (n = 3 per group). Data were then analyzed using Student's t-test and Mann-Whitney statistical methods. Results: The SB group exhibited a higher mean SBS (10.33 MPa) compared to the CB Group (8.77 MPa). However, there was no statistical difference between the groups (p = 0.376). Both SB and CB groups had a mean ARI score of 1. Raman analysis revealed a higher degree of conversion in the SB group (49.3%) compared to the CB group (25.9%). Conclusions: The experimental support showed a higher degree of adhesive conversion, although there was no significant increase in bond strength.


Subject(s)
Composite Resins , Dental Bonding , Dental Enamel , Orthodontic Brackets , Polymerization , Shear Strength , Animals , Cattle , Dental Bonding/methods , Dental Enamel/chemistry , Composite Resins/chemistry , Materials Testing , Dental Cements/chemistry , Resin Cements/chemistry
8.
Clin Oral Investig ; 28(6): 338, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38797781

ABSTRACT

OBJECTIVES: To clinically compare the effects of broader archwires to standard archwires, using conventional brackets in both cases, on the transverse and incisor changes in maxillary and mandibular arches during leveling and alignment. MATERIALS AND METHODS: Fifty-two patients presenting with crowding were allocated into two groups; one group received the broad Damon archwires while the other received standard 3M OrthoForm III Ovoid archwires. All participants were treated with conventional brackets using similar archwire sequences (0.014, 0.018, 0.016 × 0.022/0.016 × 0.025, 0.019 × 0.025 NiTi/CuNiTi archwires). Digital casts were obtained from alginate impressions before treatment (T0) and six weeks after inserting 0.019 × 0.025 NiTi archwires (T1). Pretreatment (T0) and post-alignment (T1) lateral cephalograms were obtained for each patient. The primary outcomes were the changes in the transverse arch dimensions and incisor inclination. The secondary outcomes were the horizontal and vertical linear changes in incisor position. RESULTS: Complete data were collected for 47 patients. There was a significant increase in arch width during treatment within each group, except for upper inter-molar width in 3M group (P = 0.071). Damon wire induced a statistically significant increase in maxillary inter-second premolar width (P = 0.042), and mandibular inter-first premolar (P = 0.043), inter-second premolar (P = 0.008) and inter-molar widths (P = 0.033) compared to 3M group. The increase in incisor proclination and the linear change in incisor position were significant within each group, with less mandibular incisor proclination (P = 0.004) and horizontal advancement (P = 0.038) in the Damon group. CONCLUSIONS: Damon archwires created a comparatively greater increase in the maxillary inter-second premolar width and the mandibular inter-first premolar, inter-second premolar, and inter-molar widths, and less proclination and horizontal advancement in mandibular incisors. The study provides invaluable evidence that using broad archwires with self-ligating brackets is the reason behind any greater expansion observed in this system rather than the unique mechanical and biological features exerted by the self-ligating system. CLINICAL RELEVANCE: Our results suggest that Damon archwire might be a better alternative compared to the narrower standard archwires that are usually used with conventional brackets, especially in the mandibular arch, in cases where mild to moderate crowding is planned to be resolved with a non-extraction approach. However, as arch expansion in the absence of posterior crossbites raises the question of long-term stability, the reported advantage of the use of wide wires should be interpreted with caution and should be considered in the retention phase, bearing in mind that achieving a good post-treatment occlusion is important for enhancing post-treatment stability.


Subject(s)
Cephalometry , Incisor , Malocclusion , Orthodontic Appliance Design , Orthodontic Brackets , Orthodontic Wires , Humans , Female , Male , Malocclusion/therapy , Adolescent , Nickel/chemistry , Dental Arch , Titanium/chemistry , Treatment Outcome , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Copper
9.
J Dent ; 146: 105073, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38782176

ABSTRACT

OBJECTIVES: Evaluate, in vitro, the effect of incorporating nano-sized sodium trimetaphosphate (TMPnano) and phosphorylated chitosan (Chi-Ph) into resin-modified glass ionomer cement (RMGIC) used for orthodontic bracket cementation, on mechanical, fluoride release, antimicrobial and cytotoxic properties. METHODS: RMGIC was combined with Chi-Ph (0.25%/0.5%) and/or TMPnano (14%). The diametral compressive/tensile strength (DCS/TS), surface hardness (SH) and degree of conversion (%DC) were determined. For fluoride (F) release, samples were immersed in des/remineralizing solutions. Antimicrobial/antibiofilm activity was evaluated by the agar diffusion test and biofilm metabolism (XTT). Cytotoxicity in fibroblasts was assessed with the resazurin method. RESULTS: After 24 h, the RMGIC-14%TMPnano group showed a lower TS value (p < 0.001); after 7 days the RMGIC-14%TMPnano-0.25%Chi-Ph group showed the highest value (p < 0.001). For DCS, the RMGIC group (24 h) showed the highest value (p < 0.001); after 7 days, the highest value was observed for the RMGIC-14%TMPnano-0.25%Chi-Ph (p < 0.001). RMGIC-14%TMPnano, RMGIC-14%TMPnano-0.25%Chi-Ph, RMGIC-14%TMPnano-0.5%Chi-Ph showed higher and similar release of F (p > 0.001). In the SH, the RMGIC-0.25%Chi-Ph; RMGIC-0.5%Chi-Ph; RMGIC-14%TMPnano-0.5%Chi-Ph groups showed similar results after 7 days (p > 0.001). The RMGIC-14%TMPnano-0.25%Chi-Ph group showed a better effect on microbial/antibiofilm growth, and the highest efficacy on cell viability (p < 0.001). After 72 h, only the RMGIC-14%TMPnano-0.25%Chi-Ph group showed cell viability (p < 0.001). CONCLUSION: The RMGIC-14%TMPnano-0.25%Chi-Ph did not alter the physical-mechanical properties, was not toxic to fibroblasts and reduced the viability and metabolism of S. mutans. CLINICAL RELEVANCE: The addition of phosphorylated chitosan and organic phosphate to RMGIC could provide an antibiofilm and remineralizing effect on the tooth enamel of orthodontic patients, who are prone to a high cariogenic challenge due to fluctuations in oral pH and progression of carious lesions.


Subject(s)
Anti-Bacterial Agents , Biofilms , Chitosan , Fibroblasts , Fluorides , Glass Ionomer Cements , Materials Testing , Chitosan/pharmacology , Anti-Bacterial Agents/pharmacology , Glass Ionomer Cements/pharmacology , Glass Ionomer Cements/chemistry , Biofilms/drug effects , Fibroblasts/drug effects , Phosphorylation , Fluorides/pharmacology , Hardness , Tensile Strength , Surface Properties , Compressive Strength , Nanoparticles , Resin Cements/chemistry , Polyphosphates/pharmacology , Dental Cements/pharmacology , Dental Cements/chemistry , Cell Survival/drug effects , Streptococcus mutans/drug effects , Animals , Phosphates/pharmacology , Humans , Orthodontic Brackets
10.
Clin Oral Investig ; 28(6): 323, 2024 May 18.
Article in English | MEDLINE | ID: mdl-38761310

ABSTRACT

OBJECTIVES: White spot lesions are the most common iatrogenic effect observed during orthodontic treatment. This study aimed to compare the surface characteristics and antibacterial action of uncoated and coated orthodontic brackets. MATERIALS AND METHODS: Sixty commercially available stainless steel brackets were coated with TiO2 nanotubes and methacryloyloxyethylphosphorylcholine. The sample was divided into Group 1: uncoated orthodontic brackets, Group 2: Stainless steel brackets with TiO2 nanotubes coating, Group 3: Stainless steel brackets with methacryloyloxyethylphosphorylcholine coating, and Group 4: Stainless steel brackets with TiO2 nanotubes combined with methacryloyloxyethylphosphorylcholine coating. Surface characterization was assessed using atomic force microscopy and scanning electron microscopy. Streptococcus mutans was selected to test the antibacterial ability of the orthodontic brackets, total bacterial adhesion and bacterial viability were assessed. The brackets were subjected to scanning electron microscopy to detect the presence of biofilm. RESULTS: The surface roughness was the greatest in Group 1 and least in Group 2 followed by Group 4 and Group 3 coated brackets. The optical density values were highest in Group 1 and lowest in Group 4. Comparison of colony counts revealed high counts in Group 1 and low counts in Group 4. A positive correlation between surface roughness and colony counts was obtained, however, was not statistically significant. CONCLUSIONS: The coated orthodontic brackets exhibited less surface roughness than the uncoated orthodontic brackets. Group 4 coated orthodontic brackets showed the best antibacterial properties. CLINICAL RELEVANCE: Coated orthodontic brackets prevent adhesion of streptococcus mutans and reduces plaque accumulation around the brackets thereby preventing formation of white spot lesions during orthodontic treatment.


Subject(s)
Anti-Bacterial Agents , Bacterial Adhesion , Microscopy, Electron, Scanning , Nanotubes , Orthodontic Brackets , Phosphorylcholine , Streptococcus mutans , Surface Properties , Titanium , Titanium/chemistry , Phosphorylcholine/analogs & derivatives , Phosphorylcholine/pharmacology , Phosphorylcholine/chemistry , Streptococcus mutans/drug effects , Anti-Bacterial Agents/pharmacology , Nanotubes/chemistry , Bacterial Adhesion/drug effects , Microscopy, Atomic Force , Materials Testing , Stainless Steel/chemistry , Methacrylates/pharmacology , Methacrylates/chemistry , Biofilms/drug effects , Coated Materials, Biocompatible/pharmacology , Coated Materials, Biocompatible/chemistry
11.
BMC Oral Health ; 24(1): 609, 2024 May 25.
Article in English | MEDLINE | ID: mdl-38796434

ABSTRACT

BACKGROUND: High speed electric handpieces have recently been growing in popularity among dental professionals. Advantages include smoother surface preparation and increased cutting efficiency. AIM: The primary objective was to compare enamel surface roughness following resin cleanup after bracket debonding using highspeed air turbine versus electric handpiece. The secondary objective was to record the time needed for resin-clean up. METHOD: Forty deidentified freshly extracted human premolars were cleaned and sectioned at the cement-enamel junction. The crowns were embedded in acrylic blocks. Enamel surface roughness parameters (Ra, Rz, Rp and Rv) were measured using a stylus profilometer. Brackets were bonded using a light-cure orthodontic adhesive and stored in distilled water for 24 h. Following bracket debonding, the specimens were randomly divided into 2 groups: First group: resin clean-up was carried out using a 12-fluted carbide bur mounted on a high-speed air turbine; and second group: where an electric handpiece was used. Surface roughness parameters were measured following resin clean up and after polishing using pumice and a rubber cup. Time needed for resin clean-up was recorded. Differences in enamel surface roughness and time between groups were compared using repeated measures ANOVA and independent samples t-test, respectively at P ≤ 0.05. RESULTS: The electric handpiece groups showed significantly higher values for Ra, Rz and Rp both following resin cleanup and polishing. Time taken for resin cleanup was significantly longer for the electric handpiece group. CONCLUSION: Considering both surface roughness and time, electric handpiece do not seem to add greater effectiveness or efficiency to resin cleanup following orthodontic bracket debonding.


Subject(s)
Dental Debonding , Dental Enamel , Dental High-Speed Equipment , Surface Properties , Humans , Dental Debonding/methods , In Vitro Techniques , Resin Cements/chemistry , Orthodontic Brackets , Time Factors , Bicuspid , Dental Polishing/methods
13.
J Clin Pediatr Dent ; 48(3): 31-36, 2024 May.
Article in English | MEDLINE | ID: mdl-38755979

ABSTRACT

The purpose of this study was to quantitatively evaluate adhesive remnants on the enamel surface following bracket debonding using a freezing element. Thirty-six sound premolars were used in this study. In each case, a bracket was bonded onto each tooth with conventional light-cured composite resin and de-bonded after one week. Freezing of the underlying composite through the bracket was performed immediately before debonding with a portable cryosurgical system (-55 °C). Specimens were divided into three groups according to the duration of freezing: a control group without freezing was used as a reference and two interventional groups with different durations of freezing (15 or 40 s). Brackets were removed by using debonding pliers to squeeze the wings of the bracket in an occluso-gingival manner. Adhesive remnants on the tooth were then quantitatively evaluated by stereo-microscopy. Pearson's Chi-squared test was used to investigate the relationship between the proportion of remaining resin and the group of teeth. In the control group, 100% of the composite remained on the enamel surface of all specimens. Significantly less adhesive remnants were found in the intervention groups (p = 0.001 for the 15 s group and p = 0.043 for the 40 s group). There was no significant difference between the two interventions (p = 0.165) in terms of the proportion of remaining adhesive remnants. Freezing of the bracket and the underlying adhesive resin prior to bracket debonding may favorably alter the behavioral pattern of composite fracture, thus reducing the extent of adhesive remnants on the enamel. Increasing the freezing time from 15 to 40 s did not exert significant effects on adhesive remnants following debonding. Further research now needs to investigate the effect of freezing on the mechanical properties of the adhesive remnants and its in-vivo effect on pulp vitality over both short- and long-terms.


Subject(s)
Composite Resins , Dental Debonding , Freezing , Orthodontic Brackets , Humans , Dental Debonding/methods , Composite Resins/chemistry , Dental Enamel , In Vitro Techniques , Resin Cements/chemistry , Dental Cements/chemistry , Bicuspid , Materials Testing
14.
Clin Oral Investig ; 28(6): 308, 2024 May 11.
Article in English | MEDLINE | ID: mdl-38733458

ABSTRACT

AIMS: This study aimed to evaluate the visual improvement of resin infiltration of white spot lesions (WSL) during orthodontic treatment with the multibracket appliance (MBA) compared to fluoride varnish. METHODS: Patients aged 12-17 years with at least one WSL with an International Caries Detection and Assessment System (ICDAS) score of 1-2 during an active MBA treatment were included and randomized to receive either resin infiltration (Icon) or fluoride application (Flairesse). Standardized digital images were obtained before, one-day, one-week, one-month, three-months and six-months after treatment using a DSLR camera and a matching polarization filter. A grey reference card was used for color standardization. A Matlab routine was used to measure the color difference between adjacent healthy enamel and treated WSL. The independent-samples t-test was used for intergroup and paired-samples t-test for intragroup comparison. RESULTS: Images of 116 teeth from 36 patients were analyzed. The ΔE for the "Icon" treated WSL was smaller (T1ICON = 5.0 ± 1.4) than in the fluoride group (T1Fluoride = 8.4 ± 3.2). Caries infiltration significantly improved the aesthetic appearance of WSL (p < 0.001), which remained satisfactory at six months (T5ICON = 5.2 ± 1.6). CONCLUSION: WSL infiltration management during orthodontic treatment was superior to topical fluoridation in not only arresting the enamel lesions but also significantly improving the aesthetic appearance of demineralized regions around the brackets. CLINICAL RELEVANCE: WSL treatment in orthodontic patients is usually initiated after debonding. Research has shown that the earlier WSL is treated, the better the aesthetic outcome. There is limited data on the efficacy of resin infiltration of WSL during orthodontic treatment.


Subject(s)
Cariostatic Agents , Dental Caries , Fluorides, Topical , Orthodontic Brackets , Adolescent , Child , Female , Humans , Male , Cariostatic Agents/therapeutic use , Dental Caries/therapy , Dental Caries/prevention & control , Fluorides, Topical/therapeutic use , Resins, Synthetic/therapeutic use , Treatment Outcome
15.
BMC Oral Health ; 24(1): 555, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38735948

ABSTRACT

OBJECTIVE: This study aimed to evaluate the effect of fence tray matching care (FTMC) in bracket bonding by measuring excess adhesive, as well as linear and angular deviations, and by comparing it with the half-wrapped tray (HWT). MATERIALS AND METHODS: An intraoral scanner was used to acquire data on the maxillary dental arch of a patient with periodontitis.Furthermore, 20 maxillary dental arch models were 3D printed. Using 3Shape, PlastyCAD software, and 3D printing technology, 10 FTMC (method I) and HWT (method II) were obtained. By preoperative preparation, intraoperative coordination, and postoperative measurement, the brackets were transferred from the trays to the 3D-printed maxillary dental arch models. Additionally, the bracket's excess adhesive as well as linear and angular deviations were measured, and the differences between the two methods were analyzed. RESULTS: Excess adhesive was observed in both methods, with FTMC showing less adhesive (P< 0.001), with a statistical difference. Furthermore, HWT's vertical, tip and torque, which was significantly greater than FTMC (P< 0.05), with no statistical difference among other respects. The study data of incisors, canines, and premolars, showed that the premolars had more adhesive residue and were more likely to have linear and angular deviations. CONCLUSIONS: The FTMC had higher bracket bonding effect in comparison to HWT, and the adhesive residue, linear and angular deviations are smaller. The fence tray offers an intuitive view of the precise bonding of the bracket, and can remove excess adhesive to prevent white spot lesions via care, providing a different bonding method for clinical applications.


Subject(s)
Dental Bonding , Orthodontic Brackets , Humans , Dental Bonding/methods , In Vitro Techniques , Models, Dental , Adhesives , Printing, Three-Dimensional , Dental Cements , Dental Arch
16.
Clin Exp Dent Res ; 10(3): e888, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38712436

ABSTRACT

OBJECTIVE: To evaluate the effects of metal primer II (MP II) on the shear bond strength (SBS) of orthodontic brackets bonded to teeth and bis-acryl composite provisional material (Bis-Acryl). MATERIAL AND METHODS: Twenty extracted human premolars specimens and 20 premolar shaped Bis-Acryl specimens were obtained and randomly divided into two surface groups. The first group consisted of human premolars (T) bonded to brackets in the conventional way while in the second (T-MP) MP II was applied on the bracket base before bonding. Similarly, one group of provisional material (PM) was prepared according to conventional treatment and another with the application of MP-II metal bonder (PM-MP). In all cases Ortho-brackets (Victory Series, 3 M) were bonded employing Transbond XT resin cement. Then the brackets were debonded under shear and the results were statistically analyzed by two-way analysis of variance and Holm Sidak at α = .05. The debonded surfaces of all specimens were examined by light microscopy and the Adhesive Remnant Index (ARI) was recorded. RESULTS: The SBS results exhibited significant differences er (p < .001). For both the T and TM the application of MP-II increased the SBS compared to respective control groups (p < .001). The T-C group was found inferior compared to PM-C (p < .001) and the same is true for the comparison between T-MP and PM-MP (p < .001). ARI indexes demonstrated that the tooth groups were characterized by a predominantly adhesive failure at the resin-dentin interface. In contrast, the control group for provisional crowns (PM-C) showed a predominantly cohesive failure mode, which moved to predominantly adhesive after the application of MP II. CONCLUSION: The application of MP II enhances the SBS on both, human enamel and provisional crown materials.


Subject(s)
Dental Bonding , Orthodontic Brackets , Resin Cements , Shear Strength , Surface Properties , Humans , Resin Cements/chemistry , Dental Bonding/methods , Bicuspid , Dental Stress Analysis , Materials Testing , Acrylic Resins/chemistry , Composite Resins/chemistry , Acid Etching, Dental/methods , Dental Enamel/chemistry , Dental Enamel/drug effects
17.
J Dent ; 145: 104992, 2024 06.
Article in English | MEDLINE | ID: mdl-38599563

ABSTRACT

OBJECTIVES: The objective of this study was to synthesize arginine loaded mesoporous silica nanoparticles (Arg@MSNs), develop a novel orthodontic adhesive using Arg@MSNs as modifiers, and investigate the adhesive performance, antibacterial activity, and biocompatibility. METHODS: Arg@MSNs were synthesized by immobilizing arginine into MSNs and characterized using transmission electron microscope (TEM), dynamic light scattering (DLS), and Fourier Transform Infrared Spectrometer (FT-IR). Arg@MSNs were incorporated into Transbond XT adhesive with different mass fraction to form functional adhesives. The degree of conversion (DC), arginine release behavior, adhesive performance, antibacterial activity against Streptococcus mutans biofilm, and cytotoxicity were comprehensively evaluated. RESULTS: TEM, DLS, and FT-IR characterizations confirmed the successful preparation of Arg@MSNs. The incorporation of Arg@MSNs did not significantly affect DC and exhibited clinically acceptable bonding strength. Compared to the commercial control, the Arg@MSNs modified adhesives greatly suppressed the metabolic activity and polysaccharide production while increased the biofilm pH values. The cell counting kit (CCK)-8 test indicated no cytotoxicity. CONCLUSIONS: The novel orthodontic adhesive containing Arg@MSNs exhibited significantly enhanced antibacterial activities and inhibitory effects on acid production compared to the commercial adhesive without compromising their bonding strength or biocompatibility. CLINICAL SIGNIFICANCE: The novel orthodontic adhesive containing Arg@MSNs exhibits potential clinical benefits in preventing demineralization of enamel surfaces around or beneath orthodontic brackets due to its enhanced antibacterial activities and acid-producing inhibitory effects.


Subject(s)
Anti-Bacterial Agents , Arginine , Biofilms , Nanoparticles , Resin Cements , Silicon Dioxide , Streptococcus mutans , Arginine/chemistry , Arginine/pharmacology , Silicon Dioxide/chemistry , Nanoparticles/chemistry , Streptococcus mutans/drug effects , Biofilms/drug effects , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Spectroscopy, Fourier Transform Infrared , Resin Cements/chemistry , Humans , Dental Cements/chemistry , Dental Cements/pharmacology , Porosity , Materials Testing , Microscopy, Electron, Transmission , Dental Bonding , Orthodontic Brackets , Hydrogen-Ion Concentration , Biocompatible Materials/chemistry
18.
Clin Oral Investig ; 28(5): 271, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38658431

ABSTRACT

OBJECTIVES: This in vitro study evaluated the effect of different colouring solutions and primer systems used in the bonding of brackets on enamel colour change and bond strength. MATERIALS AND METHODS: 120 premolar teeth were divided into four main groups; brackets were bonded with 37% orthophosphoric acid + Transbond XT Primer in Group 1, 3 M Single Bond Universal in Group 2, Transbond Plus SEP in Group 3, and G-Premio Bond in Group 4. Each group was divided into three subgroups, and the teeth were placed in a cup containing coffee and tea mixture, in a cup containing cola and in distilled water. A bond strength test was applied to all teeth. Colour measurements of all teeth were performed at 2 different times: before bonding and after the bond strength test. RESULTS: The average bond strength of the 37% orthophosphoric acid group was higher than that of the other groups. The effect of primer and solution groups on colour change was statistically significant (p = 0.001 and p = 0.023, respectively). CONCLUSIONS: In this study, the bond strength was clinically sufficient in all primer groups. The highest colour change was observed when the tea-coffee solution and Transbond Plus SEP primer were used. CLINICAL RELEVANCE: This study has identified enamel discoloration and bond strength from different colouring solutions and primer systems used for bonding braces, which can be used to inform clinicians and patients to achieve better treatment results.


Subject(s)
Bicuspid , Bisphenol A-Glycidyl Methacrylate , Dental Bonding , Orthodontic Brackets , Resin Cements , Shear Strength , Humans , Dental Bonding/methods , In Vitro Techniques , Resin Cements/chemistry , Color , Coloring Agents , Materials Testing , Dental Enamel/chemistry , Dental Stress Analysis , Phosphoric Acids/chemistry , Surface Properties , Tea/chemistry , Acid Etching, Dental
19.
Clin Oral Investig ; 28(5): 280, 2024 Apr 27.
Article in English | MEDLINE | ID: mdl-38671235

ABSTRACT

OBJECTIVES: The aim of this study was to compare the effect of office bleaching of teeth bonded with Transbond XTTM (3M Unitek, Monrovia, CA, USA) (TRXT) and the use of color change resistant Orthocem (FGM, Joinville, Brazil) in bracket bonding on coffee-induced enamel discoloration. MATERIALS AND METHODS: Eighty premolars were distributed in equal numbers (n = 20) to group 1 (TRXT + distilled water), group 2 (TRXT + coffee solution), group 3 (TRXT + coffee solution + bleaching), and group 4 (Orthocem + coffee solution). Color was measured using a SpectroShade Micro (MHT, International, Verona, Italy) device at the beginning (T0), after coloring (T1), after bleaching (T1B), and after debonding (T2). ΔE color change values were calculated as T1-T0, T1B-T0 and T2-T0 differences. The conformity of the data to the normal distribution was examined with the Shapiro-Wilk test. Multiple comparisons were made with Tamhane's T2 test and Tukey's HSD test using one-way analysis of variance in the comparison of normally distributed data, and multiple comparisons were made with Dunn's test using the Kruskal-Wallis H test for comparison of non-normally distributed data. The significance level was set at p < 0.050. RESULTS: A statistically significant (p < 0.001) difference was found between the T1-T0 and T2-T0 stages for group 1-4 ΔE values. A statistically significant (p < 0.001) difference was also found when the T1B-T0 ΔE values of group 3 were compared with the T1-T0 ΔE values of groups 1, 2, and 4. CONCLUSIONS: After coffee-induced enamel discoloration, bleaching of teeth bonded with TRXT produced acceptable color difference of the incisal, middle, and gingival regions of the crown. In teeth bonded with Orthocem, acceptable color difference was seen only in the middle of the crown. CLINICAL RELEVANCE: The presented study will guide the clinician on how enamel discoloration side effect of fixed orthodontic appliance can reduce.


Subject(s)
Orthodontic Brackets , Tooth Bleaching , Tooth Discoloration , Humans , In Vitro Techniques , Tooth Bleaching/methods , Tooth Bleaching/adverse effects , Tooth Discoloration/chemically induced , Surface Properties , Bicuspid , Tooth Bleaching Agents/chemistry , Coffee , Resin Cements/chemistry , Color , Dental Bonding/methods , Materials Testing
20.
Dental Press J Orthod ; 29(1): e2423133, 2024.
Article in English | MEDLINE | ID: mdl-38567922

ABSTRACT

OBJECTIVE: This study aimed to assess the frequency with which orthodontic patients decided to shift to another type of orthodontic appliance, among conventional metal brackets, ceramic brackets, lingual brackets and clear aligner, based on their personal experiences of pain, ulcers, bad breath, hygiene issues and social difficulties. MATERIAL AND METHODS: This study comprises of patients seeking orthodontic treatment. The sample (n = 500; age group = 19-25 years) was divided equally into four groups based on the treatment modality: conventional metal brackets, ceramic brackets, lingual brackets and clear aligner. Patients rated the questionnaire using a visual analogue scale, to assess variables (such as pain, ulcer etc) that impact various treatment modalities. Subsequently, patients from all groups provided feedback regarding their treatment experiences, and expressed their preference for an alternative modality. Intergroup comparison among the four groups was done using one-way analysis of variance with Tukey's HSD post-hoc test (p ≤ 0.05). RESULTS: Patients who received lingual brackets reported higher levels of pain and ulceration, as compared to those who received clear aligners. All four groups showed statistically significant differences for ulcers during treatment (p ≤ 0.05). Of the 125 patients who received conventional metal brackets, 28% expressed a preference for clear aligner therapy, while 20% preferred ceramic brackets. In the lingual group, 56% of 125 patients preferred clear aligner therapy, and 8% preferred ceramic brackets to complete their treatment. In the ceramic group, 83% did not want to switch, whereas 17% desired to switch to clear aligner, while in aligner group no patient desired to switch. CONCLUSIONS: A higher percentage of patients from lingual brackets group chose to shift to clear aligners, followed by conventional metal brackets group and by ceramic brackets group, in this descending order. The clear aligner group demonstrated fewer issues than the other treatment modalities.


Subject(s)
Orthodontic Brackets , Ulcer , Humans , Young Adult , Adult , Orthodontic Appliances , Ceramics , Pain
SELECTION OF CITATIONS
SEARCH DETAIL
...