Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30.062
Filter
1.
Rev Assoc Med Bras (1992) ; 70(4): e20230998, 2024.
Article in English | MEDLINE | ID: mdl-38716936

ABSTRACT

OBJECTIVE: The use of cardiac implantable electronic devices has increased in recent years. It has also brought some issues. Among these, the complications of cardiac implantable electronic devices infection and pocket hematoma are difficult to manage. It can be fatal with the contribution of patient-related risk factors. In this study, we aimed to find mortality rates in patients who developed cardiac implantable electronic devices infection and pocket hematoma over 5 years. We also investigated the risk factors affecting mortality in patients with cardiac implantable electronic devices. METHODS: A total of 288 cardiac implantable electronic devices patients were evaluated. Demographic details, history, and clinical data of all patients were recorded. Cardiac implantable electronic devices infection was defined according to the modified Duke criteria. The national registry was used to ascertain the mortality status of the patients. The patients were divided into two groups (exitus and survival groups). In addition, the pocket hematoma was defined as significant bleeding at the pocket site after cardiac implantable electronic devices placement. RESULTS: The cardiac implantable electronic devices infection was similar in both groups (p=0.919), and the pocket hematoma was higher in the exitus group (p=0.019). The exitus group had higher usage of P2Y12 inhibitors (p≤0.001) and novel oral anticoagulants (p=0.031). The Cox regression analysis, including mortality-related factors, revealed that renal failure is the most significant risk factor for mortality. Renal failure was linked to a 2.78-fold higher risk of death. CONCLUSION: No correlation was observed between cardiac implantable electronic devices infection and mortality, whereas pocket hematoma was associated with mortality. Furthermore, renal failure was the cause of the highest mortality rate in patients with cardiac implantable electronic devices.


Subject(s)
Defibrillators, Implantable , Hematoma , Pacemaker, Artificial , Humans , Female , Male , Defibrillators, Implantable/adverse effects , Risk Factors , Aged , Middle Aged , Pacemaker, Artificial/adverse effects , Hematoma/etiology , Hematoma/mortality , Prosthesis-Related Infections/mortality , Prosthesis-Related Infections/etiology , Retrospective Studies , Time Factors , Aged, 80 and over
2.
Sci Rep ; 14(1): 10440, 2024 05 07.
Article in English | MEDLINE | ID: mdl-38714750

ABSTRACT

A wide variety of treatments have been developed to improve respiratory function and quality of life in patients with bilateral vocal fold paresis (BVFP). One experimental method is the electrical activation of the posterior cricoarytenoid (PCA) muscle with a laryngeal pacemaker (LP) to open the vocal folds. We used an ovine (sheep) model of unilateral VFP to study the long-term effects of functional electrical stimulation on the PCA muscles. The left recurrent laryngeal nerve was cryo-damaged in all animals and an LP was implanted except for the controls. After a reinnervation phase of six months, animals were pooled into groups that received either no treatment, implantation of an LP only, or implantation of an LP and six months of stimulation with different duty cycles. Automated image analysis of fluorescently stained PCA cross-sections was performed to assess relevant muscle characteristics. We observed a fast-to-slow fibre type shift in response to nerve damage and stimulation, but no complete conversion to a slow-twitch-muscle. Fibre size, proportion of hybrid fibres, and intramuscular collagen content were not substantially altered by the stimulation. These results demonstrate that 30 Hz burst stimulation with duty cycles of 40% and 70% did not induce PCA atrophy or fibrosis. Thus, long-term stimulation with an LP is a promising approach for treating BVFP in humans without compromising muscle conditions.


Subject(s)
Disease Models, Animal , Electric Stimulation Therapy , Laryngeal Muscles , Vocal Cord Paralysis , Animals , Sheep , Vocal Cord Paralysis/therapy , Vocal Cord Paralysis/physiopathology , Electric Stimulation Therapy/methods , Laryngeal Muscles/physiopathology , Humans , Pacemaker, Artificial/adverse effects , Vocal Cords/physiopathology , Vocal Cords/pathology , Female
3.
Card Electrophysiol Clin ; 16(2): 139-142, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749632

ABSTRACT

This case report discusses a 42-year-old male with dextro-transposition of the great arteries (D-TGA) status post Mustard repair and sick sinus syndrome status post dual-chamber pacemaker implant, who developed symptomatic superior vena cava (SVC) baffle stenosis. He was treated with a combined pacemaker extraction and subsequent SVC baffle stenting. The case highlights the complexities of treating SVC baffle stenosis in the presence of cardiac implantable devices and demonstrates the efficacy of this combined approach. Furthermore, the authors delve into the intricacies of D-TGA, its surgical history, and the long-term complications associated with atrial switch procedures.


Subject(s)
Device Removal , Pacemaker, Artificial , Stents , Transposition of Great Vessels , Humans , Transposition of Great Vessels/surgery , Male , Adult , Pacemaker, Artificial/adverse effects , Superior Vena Cava Syndrome/surgery , Superior Vena Cava Syndrome/etiology , Sick Sinus Syndrome/therapy , Sick Sinus Syndrome/surgery
4.
Card Electrophysiol Clin ; 16(2): 143-147, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749633

ABSTRACT

We present a complex case of cardiac implantable electronic device infection and extraction in the setting of bacteremia, large lead vegetation, and patent foramen ovale. Following a comprehensive preprocedural workup including transesophageal echocardiogram and computed tomography lead extraction protocol, in addition to the involvement of multiple subspecialties, an open chest approach to extraction was deemed a safer option for eradication of the patient's infection. Despite percutaneous techniques having evolved as the preferred extraction method during the last few decades, this case demonstrates the importance of a thorough evaluation at an experienced center to determine the need for open chest extraction.


Subject(s)
Defibrillators, Implantable , Device Removal , Pacemaker, Artificial , Prosthesis-Related Infections , Humans , Device Removal/methods , Defibrillators, Implantable/adverse effects , Prosthesis-Related Infections/surgery , Prosthesis-Related Infections/diagnostic imaging , Pacemaker, Artificial/adverse effects , Male , Echocardiography, Transesophageal , Tomography, X-Ray Computed , Aged , Foramen Ovale, Patent/surgery , Foramen Ovale, Patent/diagnostic imaging , Female , Middle Aged
5.
Card Electrophysiol Clin ; 16(2): 117-124, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749629

ABSTRACT

Transvenous laser lead extraction poses a risk of major complications (0.19%-1.8%), notably injury to the superior vena cava (SVC) in 0.19% to 0.96% of cases. Various factors contribute to SVC injury, which can be categorized as patient-related (such as female gender, low body mass index, diabetes, renal problems, anemia, and reduced ejection fraction), device-related (including the number, dwell time, and type of leads), or procedural-related (such as reason for extraction, venous obstructions, and bilateral lead placements).


Subject(s)
Device Removal , Laser Therapy , Vena Cava, Superior , Humans , Vena Cava, Superior/injuries , Vena Cava, Superior/surgery , Female , Device Removal/adverse effects , Male , Laser Therapy/adverse effects , Middle Aged , Aged , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects
6.
Card Electrophysiol Clin ; 16(2): 149-155, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749634

ABSTRACT

Leadless pacemaker systems (LPs) were developed as an alternative to traditional transvenous permanent pacemakers (TV-PPM) due to increasing rates of device and procedural related complications, leading to a high-cost burden to our health-care system. LPs were initially indicated for single-chamber ventricular pacing; however, recent developments have allowed for dual-chamber pacing too. These systems have demonstrated highly successful implant rates with stable pacing performance. This article describes the retrieval techniques of the Micra LPs and ways to mitigate challenges encountered during the retrieval process.


Subject(s)
Device Removal , Pacemaker, Artificial , Humans , Cardiac Pacing, Artificial/methods
7.
J Cardiothorac Surg ; 19(1): 296, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38778360

ABSTRACT

BACKGROUND: There is little literature on the use of temporary pacemakers in children with fulminant myocarditis. Therefore, we summarized the use of temporary cardiac pacemakers in children with fulminant myocarditis in our hospital. METHODS: The clinical data of children with fulminant myocarditis treated with temporary pacemakers in Wuhan Children's Hospital from January 2017 to May 2022 were retrospectively analyzed. RESULTS: A total of 6 children were enrolled in the study, including 4 boys and 2 girls, with a median age of 50 months and a median weight of 15 kg. The average time from admission to pacemaker placement was 2.75 ± 0.4 h. The electrocardiogram showed that all 6 children had third-degree atrioventricular block (III°AVB). The initial pacing voltage, the sensory sensitivity of the ventricle and the pacing frequency were set to 5-10 mV, 5 V and 100-120 bpm respectively. The sinus rhythm was recovered in 5 patients within 61 h (17-134) h, and the median time of using temporary pacemaker was 132 h (63-445) h. One of the children had persistent III°AVB after the temporary pacemaker. With parental consent, the child was fitted with a permanent pacemaker on the 12th day of his illness. CONCLUSIONS: When fulminant myocarditis leads to severe bradycardia or atrioventricular block in children, temporary pacemakers have the characteristics of high safety to improve the heart function.


Subject(s)
Atrioventricular Block , Myocarditis , Pacemaker, Artificial , Humans , Myocarditis/therapy , Myocarditis/physiopathology , Male , Female , Child, Preschool , Retrospective Studies , Child , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Infant , Electrocardiography , Cardiac Pacing, Artificial/methods , Bradycardia/therapy , Bradycardia/physiopathology , Treatment Outcome
9.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38749619

ABSTRACT

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/surgery , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/adverse effects , Severity of Illness Index
10.
Card Electrophysiol Clin ; 16(2): 157-161, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749635

ABSTRACT

Cardiac implantable electronic device leads can contribute to tricuspid regurgitation and also complicate surgical and transcatheter interventions to manage tricuspid regurgitation. Here we present a case of a patient with sinus node dysfunction and complete heart block who underwent extraction of a right ventricular pacing lead before tricuspid valve surgery. We review the data regarding the contribution of leads to tricuspid regurgitation and the benefits of lead extraction, risks of jailing leads during tricuspid interventions, and pacing considerations around tricuspid valve procedures.


Subject(s)
Pacemaker, Artificial , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/surgery , Pacemaker, Artificial/adverse effects , Male , Aged , Heart Block/therapy , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Female
11.
Card Electrophysiol Clin ; 16(2): 133-138, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749631

ABSTRACT

Persistent left superior vena cava (PLSVC) is an anatomic variant that is relatively uncommon in the general population. Lead extraction through PLSVC is extremely rare. Due to unusual anatomy, the procedure carries challenges that require special considerations and careful planning. The authors report a case of lead extraction through a PLSVC with occluded right superior vena cava and highlight the challenges and outcomes of the procedure.


Subject(s)
Device Removal , Superior Vena Cava Syndrome , Vena Cava, Superior , Humans , Vena Cava, Superior/abnormalities , Vena Cava, Superior/surgery , Vena Cava, Superior/diagnostic imaging , Superior Vena Cava Syndrome/surgery , Superior Vena Cava Syndrome/diagnostic imaging , Persistent Left Superior Vena Cava/surgery , Persistent Left Superior Vena Cava/diagnostic imaging , Male , Defibrillators, Implantable , Pacemaker, Artificial , Female
12.
Arq Bras Cardiol ; 121(4): e20230386, 2024 Apr.
Article in Portuguese, English | MEDLINE | ID: mdl-38695408

ABSTRACT

BACKGROUND: The use of artificial cardiac pacemakers has grown steadily in line with the aging population. OBJECTIVES: To determine the rates of hospital readmissions and complications after pacemaker implantation or pulse generator replacement and to assess the impact of these events on annual treatment costs from the perspective of the Unified Health System (SUS). METHODS: A prospective registry, with data derived from clinical practice, collected during index hospitalization and during the first 12 months after the surgical procedure. The cost of index hospitalization, the procedure, and clinical follow-up were estimated according to the values reimbursed by SUS and analyzed at the patient level. Generalized linear models were used to study factors associated with the total annual treatment cost, adopting a significance level of 5%. RESULTS: A total of 1,223 consecutive patients underwent initial implantation (n=634) or pulse generator replacement (n=589). Seventy episodes of complication were observed in 63 patients (5.1%). The incidence of hospital readmissions within one year was 16.4% (95% CI 13.7% - 19.6%) after initial implants and 10.6% (95% CI 8.3% - 13.4%) after generator replacements. Chronic kidney disease, history of stroke, length of hospital stays, need for postoperative intensive care, complications, and hospital readmissions showed a significant impact on the total annual treatment cost. CONCLUSIONS: The results confirm the influence of age, comorbidities, postoperative complications, and hospital readmissions as factors associated with increased total annual treatment cost for patients with pacemakers.


FUNDAMENTO: O uso de marca-passos cardíacos artificiais tem crescido constantemente, acompanhando o envelhecimento populacional. OBJETIVOS: Determinar as taxas de readmissões hospitalares e complicações após implante de marca-passo ou troca de gerador de pulsos e avaliar o impacto desses eventos nos custos anuais do tratamento sob a perspectiva do Sistema Único de Saúde (SUS). MÉTODOS: Registro prospectivo, com dados derivados da prática clínica assistencial, coletados na hospitalização índice e durante os primeiros 12 meses após o procedimento cirúrgico. O custo da hospitalização índice, do procedimento e do seguimento clínico foram estimados de acordo com os valores reembolsados pelo SUS e analisados ao nível do paciente. Modelos lineares generalizados foram utilizados para estudar fatores associados ao custo total anual do tratamento, adotando-se um nível de significância de 5%. RESULTADOS: No total, 1.223 pacientes consecutivos foram submetidos a implante inicial (n= 634) ou troca do gerador de pulsos (n= 589). Foram observados 70 episódios de complicação em 63 pacientes (5,1%). A incidência de readmissões hospitalares em um ano foi de 16,4% (IC 95% 13,7% - 19,6%) após implantes iniciais e 10,6% (IC 95% 8,3% - 13,4%) após trocas de geradores. Doença renal crônica, histórico de acidente vascular encefálico, tempo de permanência hospitalar, necessidade de cuidados intensivos pós-operatórios, complicações e readmissões hospitalares mostraram um impacto significativo sobre o custo anual total do tratamento. CONCLUSÕES: Os resultados confirmam a influência da idade, comorbidades, complicações pós-operatórias e readmissões hospitalares como fatores associados ao incremento do custo total anual do tratamento de pacientes com marca-passo.


Subject(s)
Pacemaker, Artificial , Patient Readmission , Humans , Pacemaker, Artificial/economics , Pacemaker, Artificial/adverse effects , Female , Male , Aged , Middle Aged , Patient Readmission/statistics & numerical data , Patient Readmission/economics , Time Factors , Aged, 80 and over , Prospective Studies , Postoperative Complications/economics , Brazil , Health Care Costs/statistics & numerical data , Risk Factors , Length of Stay/economics
14.
Sci Rep ; 14(1): 11130, 2024 05 15.
Article in English | MEDLINE | ID: mdl-38750100

ABSTRACT

CMR at 3.0T in the presence of active cardiac implants remains a challenge due to susceptibility artifacts. Beyond a signal void that cancels image information, magnetic field inhomogeneities may cause distorted appearances of anatomical structures. Understanding influencing factors and the extent of distortion are a first step towards optimizing the image quality of CMR with active implants at 3.0T. All measurements were obtained at a clinical 3.0T scanner. An in-house designed phantom with a 3D cartesian grid of water filled spheres was used to analyze the distortion caused by four representative active cardiac devices (cardiac loop recorder, pacemaker, 2 ICDs). For imaging a gradient echo (3D-TFE) sequence and a turbo spin echo (2D-TSE) sequence were used. The work defines metrics to quantify the different features of distortion such as changes in size, location and signal intensity. It introduces a specialized segmentation technique based on a reaction-diffusion-equation. The distortion features are dependent on the amount of magnetic material in the active implants and showed a significant increase when measured with the 3D TFE compared to the 2D TSE. This work presents a quantitative approach for the evaluation of image distortion at 3.0T caused by active cardiac implants and serves as foundation for both further optimization of sequences and devices but also for planning of imaging procedures.


Subject(s)
Imaging, Three-Dimensional , Magnetic Resonance Imaging , Phantoms, Imaging , Humans , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Artifacts , Pacemaker, Artificial
16.
Forensic Sci Int ; 359: 112001, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38714107

ABSTRACT

BACKGROUND: Cardiac implantable electronic devices (CIED) are a heterogeneous group of medical devices with increasingly sophisticated diagnostic capabilities, which could be exploited in forensic investigations. However, current guidelines are lacking clear recommendations on the topic. The first aim of this systematic review is to provide an updated assessment of the role of postmortem CIED interrogation, and to give practical recommendations, which can be used in daily practice. Secondly, the authors aim to determine the rates of postmortem CIED interrogation and autopsy investigations, the type of final rhythm detected close to death (with a focus on the significance of documented arrhythmias), as well as the role of postmortem CIED interrogation in the determination of final cause/time of death, and any potentially fatal device malfunctions. METHODS: A systematic search in MEDLINE and Scopus aiming to identify reports concerning postmortem human CIED interrogation was performed, including a systematic screening of reference lists. Case reports, letters to the editors, commentaries, review articles or guidelines were excluded, along with studies related to cardiac devices other than CIED. All data were pooled and analyzed using fixed-effects meta-analysis models, and the I2 statistic was used to assess heterogeneity. RESULTS: A total of 25 articles were included in the systematic review, enrolling 3194 decedent CIED carriers. Ten studies (40%) had a 100% autopsy rate, whereas in further 6 studies autopsy findings were variably reported; CIED interrogation was available from 22 studies (88%), and it was never performed prior to autopsy. The overall rate of successful postmortem CIED interrogation was 89%, with high heterogeneity among studies, mainly due to device deactivation/battery discharge. Twenty-four percent of CIED carriers experienced sudden cardiac death (SCD), whereas non-sudden cardiac and non-cardiac death (NSCD, NCD) were reported in 37% and 30% of decedents, respectively. Ventricular tachyarrhythmias were recorded in 34% of overall successfully interrogated CIED, and in 62% of decedents who experienced a SCD; of all ventricular tachyarrhythmias recorded, 40% was found in NSCD or NCD. A clear interpretation of the etiological role of recorded arrhythmias in the causation of death required integration with autopsy findings. Overall, potentially fatal device malfunctions were detected in 12% of cases. CONCLUSIONS: Postmortem CIED interrogation is a valuable tool for the determination of the cause of death, and may complement autopsy. Forensic pathologists need to know the potential utility, pitfalls, and limitations of this diagnostic examination to make this tool as much reliable as possible.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Pacemaker, Artificial/adverse effects , Arrhythmias, Cardiac , Equipment Failure
18.
Med Sci Monit ; 30: e944114, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38776271

ABSTRACT

BACKGROUND Long-term right ventricular (RV) pacing has been linked to left atrial enlargement (LAE). The incidence and risk factors associated with significant LAE after RV pacing remain unknown. This retrospective study included 461 patients requiring RV pacing at 2 centers between 2012 and 2020 and aimed to evaluate the incidence, risk factors, outcomes, and complications of LAE. MATERIAL AND METHODS A total of 461 patients with normal-sized pre-implant left atrial dimension and dual-chamber pacing pacemaker implantation for complete atrioventricular block were enrolled. Patients were grouped based on a ≥20% increase from their baseline left atrial dimension by echocardiography, indicating significant LAE, and initial characteristics, echocardiographic data, and outcomes were compared. RESULTS During a mean 7.0±4.9 years follow-up period, 96 patients (20.8%) developed significant LAE, whereas 365 patients did not. In multivariate logistic regression analysis, smaller pre-implant left atrial dimension (OR, 0.776; 95% CI, 0.728-0.828; P<0.001), lower post-implant left ventricular ejection fraction (OR, 0.976; 95% CI, 0.957-0.995; P=0.014), post-implant development of moderate to severe mitral regurgitation (OR, 2.357; 95% CI, 1.172-4.740; P=0.016), and RV pacing duration ≥3.3 years (OR, 1.576; 95% CI, 1.039-2.646; P=0.045) were independent predictors of significant LAE after RV-dependent pacing. There was a significant difference in the incident stroke events between patients without and with significant LAE (9.9% vs 17.7%; log-rank P=0.047). CONCLUSIONS Long-term RV pacing was linked to significant LAE in 20.8% of patients with complete atrioventricular block, with those affected experiencing a higher stroke rate during follow-up.


Subject(s)
Cardiac Pacing, Artificial , Echocardiography , Heart Atria , Heart Ventricles , Humans , Female , Male , Retrospective Studies , Risk Factors , Incidence , Aged , Heart Atria/physiopathology , Cardiac Pacing, Artificial/methods , Cardiac Pacing, Artificial/adverse effects , Middle Aged , Heart Ventricles/physiopathology , Echocardiography/methods , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Cardiomegaly/physiopathology , Pacemaker, Artificial , Treatment Outcome , Aged, 80 and over
19.
Herz ; 49(3): 233-246, 2024 Jun.
Article in German | MEDLINE | ID: mdl-38709278

ABSTRACT

Cardiac device therapy provides not only treatment options for bradyarrhythmia but also advanced treatment for heart failure and preventive measures against sudden cardiac death. In heart failure treatment it enables synergistic reverse remodelling and reduces pharmacological side effects. Cardiac resynchronization therapy (CRT) has revolutionized the treatment of reduced left ventricular ejection fraction (LVEF) and left bundle branch block by decreasing the mortality and morbidity with improvement of the quality of life and resilience. Conduction system pacing (CSP) as an alternative method of physiological stimulation can improve heart function and reduce the risk of pacemaker-induced cardiomyopathy. Leadless pacers and subcutaneous/extravascular defibrillators offer less invasive options with lower complication rates. The prevention of infections through preoperative and postoperative strategies enhances the safety of these therapies.


Subject(s)
Defibrillators, Implantable , Heart Failure , Humans , Heart Failure/therapy , Heart Failure/prevention & control , Pacemaker, Artificial , Treatment Outcome , Evidence-Based Medicine , Death, Sudden, Cardiac/prevention & control , Cardiac Resynchronization Therapy/methods
20.
Isr Med Assoc J ; 26(5): 273-277, 2024 May.
Article in English | MEDLINE | ID: mdl-38736340

ABSTRACT

BACKGROUND: Cardiac implantable electronic devices (CIEDs) are increasingly being used; thus, there is an increasing need for transvenous lead extraction (TLE). OBJECTIVES: To summarize our experience with TLE at single referral center in northern Israel. METHODS: The study included all patients who underwent TLE at our center between 2019 and 2022, regardless of the indication. RESULTS: The cohort included 50 patients. The mean age was 69 ± 10.36 years; 78% were males. A total of 99 electrodes were targeted. The mean number of electrodes was 1.96 (range 1-4) per patient. The time between lead implantation and extraction ranged between 1.1 and 34 years with an average of 8.14 ± 5.71 years (median of 7.5 years). Complete lead removal was achieved in 98% of patients and in 98.99% of leads. The complete procedural success rate as well as the clinical procedural success rate was 96%. The procedural failure rate was 4% (1 patient died 2 days after the index procedure and 1 patient remained with large portion of lead). The indication for TLE was infection in 78% of the cohort group. Powered mechanical sheaths were used in 36 patients (72%), laser sheaths in 27 (54%), and a combination of laser and mechanical sheaths in 16 (32%). CONCLUSIONS: The clinical and procedural success rates of TLE, primarily for CEID-related infection, were high. A combination of laser and mechanical sheaths was needed in one-third of patients.


Subject(s)
Defibrillators, Implantable , Device Removal , Pacemaker, Artificial , Humans , Device Removal/methods , Device Removal/statistics & numerical data , Male , Israel/epidemiology , Female , Aged , Retrospective Studies , Treatment Outcome , Middle Aged , Electrodes, Implanted , Aged, 80 and over
SELECTION OF CITATIONS
SEARCH DETAIL
...