Medicine (Baltimore) ; 103(27): e38391, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38968465

ABSTRACT

The objective was to assess the diagnostic efficacy of Doppler ultrasound in detecting cervical lymph nodes in patients diagnosed with laryngeal and hypopharyngeal cancers. Patients undergoing surgery for laryngeal and hypopharyngeal cancers in the Otolaryngology Department from January 2021 to January 2023 were included. Two groups, with equal numbers, underwent ultrasound examination and intensive CT examination in the experimental and control groups, respectively, along with routine cervical lymph node dissection. A resident with over 6 years of clinical experience in the otolaryngology department performed routine bilateral cervical lymph node palpation. Sensitivity, specificity, and validity were compared among different examination methods. The McNemar test assessed specificity and sensitivity between palpation, color Doppler ultrasonography, and enhanced CT, while the Kappa concordance test evaluated the concordance between the 2 examination methods. Data were statistically analyzed using SPSS 23.0. Palpation showed a diagnostic sensitivity (DS) of 52.83% and specificity of 91.11% for all patients with cervical lymph node metastasis. Ultrasonography demonstrated a DS of 77.78% and specificity of 81.82% in patients with cervical lymph node metastasis, while intensive CT had a DS of 75.86% and specificity of 60.00%. Statistical significance (P < .05) was observed in the sensitivity between palpation and ultrasonography, and between palpation and enhanced CT. The specificity between enhanced CT and ultrasonography (P = .021) and between palpation and enhanced CT scan (P = .003) both showed statistical significance (P < .05). Doppler ultrasound yields diagnostic results highly consistent with pathological diagnoses in patients with laryngeal and hypopharyngeal cancers. Utilizing Doppler ultrasound can enhance the accuracy of diagnosing these cancers, aiding physicians in devising more suitable treatment plans for patients.


Subject(s)
Hypopharyngeal Neoplasms , Laryngeal Neoplasms , Lymph Nodes , Lymphatic Metastasis , Neck , Sensitivity and Specificity , Humans , Hypopharyngeal Neoplasms/diagnostic imaging , Hypopharyngeal Neoplasms/pathology , Male , Female , Middle Aged , Lymphatic Metastasis/diagnostic imaging , Laryngeal Neoplasms/diagnostic imaging , Laryngeal Neoplasms/pathology , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Neck/diagnostic imaging , Aged , Ultrasonography, Doppler/methods , Ultrasonography, Doppler, Color/methods , Palpation , Adult , Tomography, X-Ray Computed/methods
2.
Clin Exp Rheumatol ; 42(6): 1272-1279, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38966943

ABSTRACT

OBJECTIVES: To examine the prevalence of temporomandibular disorders (TMD) in patients with juvenile fibromyalgia syndrome (JFS) and identify TMD characteristics specifically associated to JFS. METHODS: Signs and symptoms of TMD were assessed using a novel clinical tool specifically devised for children that consists of: 1. a self-report multiple-choice questionnaire; 2. a protocol for the clinical examination of the orofacial region. Multivariate logistic regression model was used to identify TMD features associated with JFS. RESULTS: Thirty JFS patients (median age 15.5 years) and 45 healthy controls (median age 15.0 years) were included in this cross-sectional study. Orofacial pain was reported by 26 of 30 JFS patients (86.7%) and by 3 of 45 controls (6.7%; p<0.001). Pain on TMJ palpation was present in 18 of 30 JFS patients (60%) and in 5 of 45 controls (11.1%; p<0.001). Median values of maximum spontaneous mouth opening, voluntary active opening and assisted passive opening were significantly higher in JFS patients than in controls. On multiple regression analysis spontaneous orofacial pain (OR: 21.0; p=0.005), diffuse tenderness on palpation of the masticatory muscles (OR: 14.9; p=0.026) and TMJ hypermobility (OR 1.42; p=0.008) were independently associated with JFS. CONCLUSIONS: The high prevalence of TMD in JFS highlights the need for a broader interdisciplinary evaluation of JFS patients. TMJ hypermobility, in addition to orofacial and masticatory muscle pain, is an important clue for the diagnosis of TMD in adolescents with JFS. Elucidating the link between these disorders will advance individualised management and improve treatment efficacy.


Subject(s)
Facial Pain , Fibromyalgia , Pain Measurement , Temporomandibular Joint Disorders , Humans , Fibromyalgia/epidemiology , Fibromyalgia/diagnosis , Fibromyalgia/physiopathology , Adolescent , Facial Pain/epidemiology , Facial Pain/diagnosis , Facial Pain/physiopathology , Facial Pain/etiology , Female , Temporomandibular Joint Disorders/epidemiology , Temporomandibular Joint Disorders/diagnosis , Temporomandibular Joint Disorders/physiopathology , Prevalence , Male , Cross-Sectional Studies , Child , Case-Control Studies , Logistic Models , Predictive Value of Tests , Palpation , Multivariate Analysis , Surveys and Questionnaires , Age Factors , Odds Ratio , Temporomandibular Joint/physiopathology , Self Report , Risk Factors
4.
Clin Neurol Neurosurg ; 243: 108355, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38843621

ABSTRACT

OBJECTIVE: to provide anatomic confirmation that standard methods which practitioners skilled in palpation use, can reliably identify the most likely site of emergence of the greater occipital nerve in most patients. The location and frequency of subcutaneous emergence of the greater occipital nerve and occipital artery with respect to the external occipital protuberance-mastoid line are reported. METHODS: The external occipital protuberance and the mastoid processes were identified by palpation bilaterally on 57 body donors and the medial trisection point of a line connecting these bony landmarks was identified. A 4 cm circular dissection guide divided into 4 quadrants was centered on the trisection point and used to guide the removal of a circle of skin. The in-situ location of the nerve and artery were exposed by deep dissection within the circle. The frequency of the emergence and occurrence of the nerve and artery by quadrant were analyzed. RESULTS: In 114 total dissections the greater occipital nerve was found to emerge within the circle 96 times (84%) and the occipital artery 100 times (88%). The nerve (90%) and artery (81%) emerged from the two inferior quadrants most of the time with no difference noted between male and female donors. The greater occipital nerve and occipital artery were found to emerge together most commonly in inferior lateral quadrant. Branches of the nerve and artery traveled together most frequently through the two lateral quadrants. CONCLUSION: This study confirmed that the medial trisection point of the external occipital protuberance-mastoid line can be located via palpation and reliably used to pinpoint the subcutaneous emergence of the greater occipital nerve and occipital artery in most individuals. When relying on palpation alone to identify the trisection point in the clinic, infusion of nerve block inferior and lateral to this point is most likely to bathe the greater occipital nerve in anesthetic.


Subject(s)
Cadaver , Occipital Bone , Palpation , Humans , Male , Female , Occipital Bone/innervation , Aged , Anatomic Landmarks , Spinal Nerves/anatomy & histology , Middle Aged , Aged, 80 and over , Mastoid/innervation
5.
PLoS One ; 19(6): e0304743, 2024.
Article in English | MEDLINE | ID: mdl-38917106

ABSTRACT

This observational study aimed to evaluate the intra- and inter-operator reliability of a digital palpation device in measuring compressive stiffness of the patellar tendon at different knee angles in talent and elite volleyball players. Second aim was to examine differences in reliability when measuring at different knee angles, between dominant and non-dominant knees, between sexes, and with age. Two operators measured stiffness at the midpoint of the patellar tendon in 45 Dutch volleyball players at 0°, 45° and 90° knee flexion, on both the dominant and non-dominant side. We found excellent intra-operator reliability (ICC>0.979). For inter-operator reliability, significant differences were found in stiffness measured between operators (p<0.007). The coefficient of variance significantly decreased with increasing knee flexion (2.27% at 0°, 1.65% at 45° and 1.20% at 90°, p<0.001). In conclusion, the device appeared to be reliable when measuring compressive stiffness of the patellar tendon in elite volleyball players, especially at 90° knee flexion. Inter-operator reliability appeared to be questionable. More standardized positioning and measurement protocols seem necessary.


Subject(s)
Palpation , Patellar Ligament , Volleyball , Humans , Volleyball/physiology , Male , Female , Patellar Ligament/physiology , Palpation/instrumentation , Palpation/methods , Reproducibility of Results , Young Adult , Adult , Range of Motion, Articular/physiology , Knee Joint/physiology , Adolescent , Biomechanical Phenomena , Observer Variation
6.
PLoS One ; 19(5): e0304571, 2024.
Article in English | MEDLINE | ID: mdl-38814967

ABSTRACT

INTRODUCTION: Clinicians commonly use manual therapy to treat low back pain by palpating the spine to identify the spinous processes. This study aims to evaluate the ability of experienced clinicians to consistently locate the spinous processes from S1 to T12 through palpation. The results will be compared to topographical data representing the lumbar lordosis at baseline and four follow-up time points. MATERIALS AND METHODS: In a prior prospective randomized trial, experienced clinicians used palpation to locate the lumbar spinous processes (S1-T12) and then digitized these locations in three-dimensional space. The same digitizing equipment was then used to continuously collect three-dimensional position data of a wheel that rolled along the back's surface through a trajectory that connected the previously digitized locations of the spinous processes. This process was repeated at 4 days, 1, 4, and 12 weeks. The resulting lordosis trajectories were plotted and aligned using the most anterior point in the lordosis to compare the locations of the spinous processes identified in different trials. This way, spinous palpation points could be compared to surface topography over time. Intra- and interrater reliability and agreement were estimated using intraclass correlations of agreement and Bland-Altman limits of agreement. RESULTS: Five clinicians palpated a total of 119 participants. The results showed a large degree of variation in precision estimates, with a mean total value of 13 mm (95%CI = 11;15). This precision error was consistent across all time points. The smallest precision error was found at L5, followed by S1 File, after which the error increased superiorly. Intra- and interrater reliability was poor to moderate. CONCLUSIONS: Comparison of palpation results to a topographic standard representing the lumbar lordosis is a new approach for evaluating palpation. Our results confirm the results of prior studies that find palpation of lumbar spinous processes imprecise, even for experienced clinicians.


Subject(s)
Lordosis , Lumbar Vertebrae , Palpation , Humans , Palpation/methods , Lumbar Vertebrae/diagnostic imaging , Female , Male , Lordosis/diagnostic imaging , Adult , Low Back Pain/diagnosis , Low Back Pain/physiopathology , Prospective Studies , Middle Aged
7.
Am J Speech Lang Pathol ; 33(4): 1802-1810, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38573246

ABSTRACT

PURPOSE: This study retrospectively examined patient-reported symptoms, quality of life, and swallowing kinematics in individuals with presumed muscle tension dysphagia (MTDg). METHOD: Twenty-six individuals met the inclusion criteria. Data were gathered from patient-reported outcome measures (PROs), symptomology, clinician reports of palpation, and hyolaryngeal and hyoid movements measured on a 20-ml thin liquid bolus during videofluoroscopic swallowing studies. RESULTS: All PROs were outside of typical limits, except for the Voice Handicap Index-10. Mean hyoid excursion was 1.52 cm (SD = 0.46, range: 0.76-2.43), and hyolaryngeal excursion was 0.77 cm (SD = 0.44, range: -0.42-1.68). A minority of participants (4%-19%) demonstrated atypical hyoid and/or hyolaryngeal excursion compared to the available normative reference value sets. CONCLUSIONS: Individuals demonstrated abnormalities in the clinical evaluation of the areas of palpation and reported perilaryngeal discomfort and symptoms of laryngeal hyperresponsiveness, with a negative impact on their quality of life across various PROs. Atypical hyoid and/or hyolaryngeal excursion during swallowing was rare when compared to available normative reference values. The clinical evaluation of MTDg may be enhanced by including components related to muscle tension and laryngeal hyperresponsiveness in order to differentiate MTDg from idiopathic functional dysphagia and lead the patient to the otolaryngology/speech-language pathology clinic for intervention and management.


Subject(s)
Deglutition Disorders , Deglutition , Muscle Tonus , Quality of Life , Humans , Deglutition Disorders/physiopathology , Deglutition Disorders/diagnosis , Male , Female , Middle Aged , Deglutition/physiology , Biomechanical Phenomena , Aged , Retrospective Studies , Adult , Muscle Tonus/physiology , Hyoid Bone/physiopathology , Patient Reported Outcome Measures , Aged, 80 and over , Fluoroscopy , Video Recording , Palpation , Laryngeal Muscles/physiopathology
8.
Int J Comput Assist Radiol Surg ; 19(6): 1147-1155, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38598140

ABSTRACT

PURPOSE: This paper evaluates user performance in telesurgical tasks with the da Vinci Research Kit (dVRK), comparing unilateral teleoperation, bilateral teleoperation with force sensors and sensorless force estimation. METHODS: A four-channel teleoperation system with disturbance observers and sensorless force estimation with learning-based dynamic compensation was developed. Palpation experiments were conducted with 12 users who tried to locate tumors hidden in tissue phantoms with their fingers or through handheld or teleoperated laparoscopic instruments with visual, force sensor, or sensorless force estimation feedback. In a peg transfer experiment with 10 users, the contribution of sensorless haptic feedback with/without learning-based dynamic compensation was assessed using NASA TLX surveys, measured free motion speeds and forces, environment interaction forces as well as experiment completion times. RESULTS: The first study showed a 30% increase in accuracy in detecting tumors with sensorless haptic feedback over visual feedback with only a 5-10% drop in accuracy when compared with sensor feedback or direct instrument contact. The second study showed that sensorless feedback can help reduce interaction forces due to incidental contacts by about 3 times compared with unilateral teleoperation. The cost is an increase in free motion forces and physical effort. We show that it is possible to improve this with dynamic compensation. CONCLUSION: We demonstrate the benefits of sensorless haptic feedback in teleoperated surgery systems, especially with dynamic compensation, and that it can improve surgical performance without hardware modifications.


Subject(s)
Robotic Surgical Procedures , Humans , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Phantoms, Imaging , Equipment Design , Telemedicine/instrumentation , Palpation/methods , Palpation/instrumentation , User-Computer Interface , Feedback , Robotics/instrumentation , Robotics/methods , Laparoscopy/methods , Laparoscopy/instrumentation
9.
J ISAKOS ; 9(3): 348-352, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38492848

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate the validity and reliability of two techniques, palpation and fluoroscopy, for assessing medial patellofemoral ligament (MPFL) reconstruction femoral tunnel position accuracy. METHODS: Twenty-one fresh frozen cadaveric knees had an MPFL femoral tunnel drilled and filled with a metal screw. Tunnels were created in a nonstandard fashion to ensure the sample included a range of tunnel positions from poor to ideal. Six experienced sport medicine and arthroscopy surgeons evaluated the placement of the femoral tunnel by palpating the screw in relation to anatomic landmarks and by fluoroscopy related to Schöttle's Point. They evaluated 1) the accuracy of femoral tunnel placement, 2) the direction of tunnel error, and 3) the clinical acceptability of the tunnel position. Validity measures included sensitivity, specificity, and correlation to clinical acceptability, which were calculated for the palpation and fluoroscopic assessments. Reliability measures included interrater reliability (ICC 2,k) for femoral tunnel accuracy and percent agreement of the raters' tunnel direction assessment. RESULTS: The palpation method demonstrated a sensitivity of 0.79 and specificity of 0.84 for assessing the accuracy of femoral tunnel placement, while the fluoroscopic method showed a sensitivity of 0.83 and specificity of 0.92. Pearson correlation coefficients for clinical acceptability of tunnel position were high, with both techniques ranging from .589 to .854. Interrater reliability for the palpation and fluoroscopic techniques for assessment of tunnel accuracy were 0.31 and 0.55 (ICC 2,k), respectively. Assessment of the direction of tunnel error was good with the fluoroscopic technique slightly more accurate than palpation. CONCLUSION: This study demonstrated that both palpation and fluoroscopy are valid techniques for assessing femoral tunnel position after MPFL reconstruction. Despite demonstrating good validity, the accuracy of assessing tunnel position was unreliable in a group of six experienced knee surgeons. Further research into MPFL reconstruction femoral tunnel assessment techniques, including patient-specific reference standards, is warranted. LEVEL OF EVIDENCE: Level 2.


Subject(s)
Cadaver , Femur , Palpation , Patellofemoral Joint , Humans , Fluoroscopy/methods , Palpation/methods , Reproducibility of Results , Femur/surgery , Femur/diagnostic imaging , Patellofemoral Joint/surgery , Patellofemoral Joint/diagnostic imaging , Male , Female , Plastic Surgery Procedures/methods , Middle Aged , Sensitivity and Specificity , Aged , Bone Screws
10.
Asian J Surg ; 47(6): 2606-2612, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38548542

ABSTRACT

BACKGROUND: The accurate evaluation of surgical margins holds crucial importance in determining the success of breast-conserving surgery (BCS). The aim of this study was to introduce a novel technique for the positioning of surgical margins in BCS while highlighting its advantages. METHODS: This study included a cohort of breast cancer patients who underwent BCS. The patients were categorized into two groups: one group underwent BCS with the traditional palpation-guided method, and the other with the 3D-MPT technique. The study assessed and compared the feasibility, advantages, and outcomes in terms of quality of life between the two groups. RESULTS: A total of 80 patients were successfully enrolled in the study. No significant differences in clinicopathological features were observed between the two groups. The 3D-MPT technique was found to be feasible and offered several advantages over the palpation-guided method. The utilization of guide wires by experienced radiologists to position the margins before surgery enabled precise and swift specimen removal, resulting in the conservation of valuable time and a reduction in the need for re-excision. Furthermore, the 3D-MPT technique exhibited the potential to enhance cosmetic outcomes and elevate patient satisfaction, particularly in cases with uncertain tumor boundaries detectable by palpation. CONCLUSION: The 3D-MPT technique proves to be an effective and safe approach for reducing tumor positivity rates in initial surgical margins, thereby improving the quality of life for patients undergoing breast-conserving surgery in comparison to the conventional method.


Subject(s)
Breast Neoplasms , Feasibility Studies , Margins of Excision , Mastectomy, Segmental , Palpation , Quality of Life , Humans , Mastectomy, Segmental/methods , Breast Neoplasms/surgery , Breast Neoplasms/pathology , Female , Palpation/methods , Middle Aged , Aged , Adult , Cohort Studies , Treatment Outcome , Imaging, Three-Dimensional , Patient Satisfaction
11.
Gastrointest Endosc ; 100(2): 317.e1-317.e9, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38431106

ABSTRACT

BACKGROUND AND AIMS: Endoscopic liver "palpation" can be performed by indenting the liver surface under EUS. Indentation depth is measured with the use of sonographic calipers. We hypothesized that fibrotic livers are more difficult to indent, and that indentation can accurately predict liver fibrosis staging. We compared EUS-guided liver palpation and conventional screening modalities in patients with suspected metabolic dysfunction-associated steatotic liver disease. METHODS: This was a cross-sectional pilot study. Consecutive patients at 3 hospitals from 2021 to 2023 underwent EUS-guided palpation with liver biopsy. Liver palpation was compared with fibrosis-4 index (FIB-4), aspartate transaminase to platelet ratio index (APRI), nonalcoholic fatty liver disease fibrosis score (NFS), and transient elastography in predicting fibrosis staging on histology. Area under the receiver operating characteristic curve analysis was performed. RESULTS: Seventy-three patients were included. Mean age was 49.1 years, and 71.2% were female. Mean body mass index was 41.1 kg/m.2 Indentation depth was negatively correlated with fibrosis stage (Kruskal-Willis test, P < .0001). EUS palpation demonstrated c-statistics of 0.79 and 0.95 in discriminating advanced fibrosis and cirrhosis, respectively. EUS liver palpation was superior to NFS in predicting advanced fibrosis (P = .0057) and superior to APRI and NFS in predicting cirrhosis (P = .0099 and P = .045, respectively). EUS palpation was not significantly different from FIB-4. EUS palpation was superior to transient elastography in predicting cirrhosis (P = .045). When optimal cutoffs were used, indentation measurement ≤3.5 mm yielded 100% predictive value for ruling in advanced fibrosis, and ≥4.0 mm yielded 100% predictive value for ruling out cirrhosis. CONCLUSIONS: EUS liver palpation is a novel, accurate, and easy-to-use screening tool for advanced fibrosis and cirrhosis in patients with metabolic dysfunction-associated steatotic liver disease.


Subject(s)
Elasticity Imaging Techniques , Endosonography , Liver Cirrhosis , Palpation , Humans , Female , Pilot Projects , Male , Middle Aged , Liver Cirrhosis/complications , Liver Cirrhosis/diagnostic imaging , Liver Cirrhosis/pathology , Cross-Sectional Studies , Elasticity Imaging Techniques/methods , Adult , Endosonography/methods , Non-alcoholic Fatty Liver Disease/diagnostic imaging , Non-alcoholic Fatty Liver Disease/complications , Non-alcoholic Fatty Liver Disease/pathology , ROC Curve , Platelet Count , Liver/diagnostic imaging , Liver/pathology , Biopsy , Aspartate Aminotransferases/blood , Aspartate Aminotransferases/metabolism , Severity of Illness Index , Aged
12.
J Bodyw Mov Ther ; 37: 1-10, 2024 01.
Article in English | MEDLINE | ID: mdl-38432788

ABSTRACT

BACKGROUND: Static palpation of vertebral spinous process deviations from the midline are often utilized by manual therapists as a means to determine area for treatment of manipulable lesions. Previous research has discussed the diagnostic validity of this technique, but no correlation to vertebral morphology has been presented. AIM: To evaluate the frequency and presentation of vertebral spinous process deviations and their relationship with articular morphology, and the impact this may have in terms of static palpation techniques in the upper thoracic spine. SETTING: This study was conducted on human T1-T6 vertebrae. METHOD: A skeletal sample consisting of 58 humans T1-T6 vertebrae were photographed and linear and angular measurements taken utilizing ImageJ software and non-metric visual observations. RESULTS: Spinous process deviations in the entire sample group (n = 348) were found to occur in a frequency ranging from 19% (n = 11) at T1 to 41.4% (n = 24) at T3. However, when evaluated in terms of frequency within an individual's T1-T6, 83.3% (n = 25) of males and 67.86% (n = 19) of females demonstrated this feature, with an overall incidence of 77.59% (n = 45). Age of individuals did not show an increase in frequency, and no clear pattern could be identified regarding metric measurements and its presence. CONCLUSION: Spinous process deviations in the upper thoracic spine are most probably the result of random normal variations between individuals and are more frequent in males. Static palpation without pain criteria is not a reliable diagnostic technique to determine areas needing manual treatment, as these may be considered normal osseous anatomical variations.


Subject(s)
Thoracic Vertebrae , Thoracic Wall , Female , Male , Humans , Allied Health Personnel , Pain , Palpation
13.
J Emerg Nurs ; 50(3): 373-380, 2024 May.
Article in English | MEDLINE | ID: mdl-38530698

ABSTRACT

INTRODUCTION: Radial artery puncture has been performed by palpation as a standard method in many emergency departments and intensive care units. Nurses play an important role in the care of patients in various settings. Ultrasonography can be performed and interpreted not only by physicians but also by nurses. This study aimed to evaluate whether emergency nurses would be more successful in radial artery puncture procedure by using ultrasonography instead of palpation. METHODS: This single-center, prospective, randomized controlled study was conducted in the emergency department. The patients included in the study were randomized into 2 groups as ultrasonography and palpation groups. Data were recorded on the number of interventions, the duration of the procedure in seconds, total time in seconds, whether the puncture was successfully placed, whether there were complications, the types of complications (hematoma, bleeding, and infection), or whether it was necessary to switch to an alternative technique. RESULTS: A total of 72 patients, 36 patients in the ultrasonography group and 36 patients in the palpation group, participated in the study. The success rate at the first attempt was statistically significantly higher in the ultrasonography group. Although hematoma formation among the complications occurred in the entire palpation group, it was observed in 72.2% of the ultrasonography group. Puncture time and total time were statistically significantly lower in the ultrasonography group. DISCUSSION: Our study shows that emergency nurses can use bedside ultrasonography for radial artery puncture successfully.


Subject(s)
Emergency Nursing , Emergency Service, Hospital , Radial Artery , Ultrasonography, Interventional , Humans , Radial Artery/diagnostic imaging , Female , Male , Prospective Studies , Emergency Nursing/methods , Middle Aged , Ultrasonography, Interventional/methods , Adult , Palpation/nursing , Palpation/methods , Aged , Punctures/methods , Catheterization, Peripheral/methods , Catheterization, Peripheral/nursing
14.
Medicina (Kaunas) ; 60(3)2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38541197

ABSTRACT

Background and Objectives: This study examined how a history of thyroid surgery impacts the precision of cricothyroid membrane (CTM) identification through palpation (validated by ultrasound) in female patients visiting the operating room for surgeries unrelated to neck procedures. Materials and Methods: This prospective observational cohort study enrolled adult female patients undergoing elective non-neck surgery, dividing them into control (no thyroid surgery history; n = 40) and experimental (with thyroid surgery history; n = 40) groups. CTM identification was performed by palpation and confirmed via ultrasound. Results: There were no significant differences between two groups in the demographic characteristics of the patients. The success rate and accuracy of CTM identification through palpation were significantly higher in the control group compared to the experimental group (90% vs. 42.5%, respectively; p < 0.001). For female patients with a history of thyroid surgery, the sensitivity of successful CTM palpation was 42.5%, and the specificity was 10%. These figures are based on the calculated true positives (17), false positives (36), true negatives (4), and false negatives (23). Conclusions: Thyroid surgery history in female patients may hinder the accurate palpation-based identification of the CTM, suggesting a need for enhanced clinical practices and considerations during airway management training.


Subject(s)
Cricoid Cartilage , Thyroid Gland , Adult , Humans , Female , Prospective Studies , Cricoid Cartilage/diagnostic imaging , Cricoid Cartilage/surgery , Thyroid Cartilage/surgery , Thyroid Cartilage/diagnostic imaging , Ultrasonography , Palpation/methods
15.
Urol Oncol ; 42(6): 176.e1-176.e7, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38508941

ABSTRACT

PURPOSE: To evaluate the value of examination under anesthesia (EUA) in the assessment of bladder resectability during cystectomy. MATERIALS AND METHODS: This prospective study included consecutive patients undergoing cystectomy for bladder cancer at a single center between June 2017 and October 2020. EUA was conducted before cystectomy by two urologists who assessed the bladder for limited mobility. One examiner was blinded to the imaging results. Soft tissue surgical margin status in the pathological evaluation of a cystectomy specimen served as a measure of resectability. We used multivariable logistic regression models to assess whether EUA performed by blinded or non-blinded examiners is associated with soft tissue positive surgical margins (PSMs) and to calculate the fraction of new information added by such an examination in addition to selected clinical variables. RESULTS: Among the 134 patients analyzed, limited bladder mobility was indicated by the blinded and non-blinded examiners in 23 (17.2%) and 21 (15.7%) cases, respectively. PSMs were identified in 22 (16.4%) patients, more often in patients with limited bladder mobility as assessed by the blinded (odds ratio [OR] 6.7; 95% confidence interval [CI], 1.9-24.2) and non-blinded examiners (OR 12.9; 95% CI, 2.9-57.5). The fraction of new information added by the blinded and non-blinded examiners was 48.6% and 57.7%, respectively. The enrichment of patients who underwent pure laparoscopic cystectomy (n = 102; 76%) and the inclusion of patients for emergent surgery may limit the generalizability of our findings. CONCLUSIONS: The identification of limited bladder mobility during preoperative EUA yielded prognostic information on surgical margin status. Our findings suggest that EUA has the potential to provide valuable insights in the assessment of bladder resectability. However, further research in a larger cohort of patients is warranted to validate and expand on these findings.


Subject(s)
Cystectomy , Laparoscopy , Palpation , Urinary Bladder Neoplasms , Humans , Cystectomy/methods , Urinary Bladder Neoplasms/surgery , Urinary Bladder Neoplasms/pathology , Prospective Studies , Female , Male , Aged , Laparoscopy/methods , Middle Aged
16.
Catheter Cardiovasc Interv ; 103(5): 722-730, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38469945

ABSTRACT

BACKGROUND: The radial first approach in cardiac catheterization is preferred for its benefits in patient comfort and recovery time. Yet, challenges persist due to characteristics like small, deep, calcified, and mobile radial arteries. Utilizing ultrasound before and during procedures can improve success rates. However, the adoption of its use is still limited and subject to debate. AIM: To utilize routine preprocedural ultrasound (US) and compare US guided with palpation guided radial access, focusing on operator efficiency and outcomes. METHODS AND RESULTS: Consenting adult patients undergoing elective radial cardiac catheterization were divided into palpation and US groups. Routine preprocedural assessment of radial artery characteristics was performed using handheld US. Baseline data, US findings, procedural outcomes, and clinical outcomes were compared in 182 participants (91 in each group). US guided radial access had significantly higher first pass success rates (76.92% vs. 49.45%, p 0.0001), fewer number of attempts (1.46 ± 1 vs. 1.99 ± 1.46, p 0.004), and shorter amount of time (93.62 ± 44.04 vs. 120.44 ± 67.1, p 0.002) compared with palpation guidance. The palpation group had significantly higher incidence of spasm (15.38% vs. 3.3%, p 0.0052). Subgroup analysis indicated consistent benefits of US guidance, especially in calcified radial arteries. CONCLUSION: This prospective, nonrandomized, single-center study demonstrated that real-time procedural US improved the operator's time and effort and enhanced patient comfort compared with palpation. US guidance use was particularly favorable in the presence of calcifications observed on baseline preoperative US.


Subject(s)
Catheterization, Peripheral , Adult , Humans , Prospective Studies , Treatment Outcome , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/methods , Palpation/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Radial Artery/diagnostic imaging , Radial Artery/surgery , Ultrasonography, Interventional/methods
17.
Comput Biol Med ; 170: 108074, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38330826

ABSTRACT

Traditional Chinese medicine (TCM) is an essential part of the Chinese medical system and is recognized by the World Health Organization as an important alternative medicine. As an important part of TCM, TCM diagnosis is a method to understand a patient's illness, analyze its state, and identify syndromes. In the long-term clinical diagnosis practice of TCM, four fundamental and effective diagnostic methods of inspection, auscultation-olfaction, inquiry, and palpation (IAOIP) have been formed. However, the diagnostic information in TCM is diverse, and the diagnostic process depends on doctors' experience, which is subject to a high-level subjectivity. At present, the research on the automated diagnosis of TCM based on machine learning is booming. Machine learning, which includes deep learning, is an essential part of artificial intelligence (AI), which provides new ideas for the objective and AI-related research of TCM. This paper aims to review and summarize the current research status of machine learning in TCM diagnosis. First, we review some key factors for the application of machine learning in TCM diagnosis, including data, data preprocessing, machine learning models, and evaluation metrics. Second, we review and summarize the research and applications of machine learning methods in TCM IAOIP and the synthesis of the four diagnostic methods. Finally, we discuss the challenges and research directions of using machine learning methods for TCM diagnosis.


Subject(s)
Artificial Intelligence , Medicine, Chinese Traditional , Humans , Medicine, Chinese Traditional/methods , Smell , Machine Learning , Palpation
18.
Int Urogynecol J ; 35(4): 823-830, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38329494

ABSTRACT

INTRODUCTION AND HYPOTHESIS: Involuntary pelvic floor muscle (PFM) contractions are thought to occur during an increase in intra-abdominal pressure (IAP). Although no studies have assessed their presence in women with normal pelvic floor (PF) function, existing literature links the absence of involuntary PFM contractions to various PF dysfunctions. This study rectifies this lacuna by evaluating involuntary PFM contractions during IAP in healthy nulliparous women with no PF dysfunction, using visual observation and vaginal palpation. Results were compared with the literature and the IUGA/ICS Terminology Reports. METHODS: Nulliparous (n=149) women performed three sets of three maximal coughs. Visual observation and vaginal palpation were conducted in the standing and supine positions. The women were not instructed to contract their PFMs. Occurrence rates were calculated for each assessment method and position; differences between positions were analyzed using the Chi-squared test. RESULTS: Rates of occurrence of involuntary PFM contraction were low across both assessments and positions (5-17%). Significant differences were found between standing (5%) and supine (15%) positions for visual observation, but not vaginal palpation (15%, 17% respectively). Occurrence rates also differed compared with the literature and terminology reports. CONCLUSIONS: Contrary to clinical expectations, rates of occurrence of involuntary PFM contraction among our cohort of nulliparous women were extremely low. Digital palpation results showed high agreement with the terminology reports, but only partial agreement was observed for the visual observation results. Our study underscores the need for more research aimed at defining normal involuntary PF functions, a review of our understanding of involuntary PFM contractions, and better standardized guidelines for involuntary PFM assessment methods.


Subject(s)
Muscle Contraction , Pelvic Floor , Humans , Female , Adult , Pelvic Floor/physiopathology , Muscle Contraction/physiology , Young Adult , Terminology as Topic , Palpation
19.
Acad Med ; 99(4S Suppl 1): S89-S94, 2024 04 01.
Article in English | MEDLINE | ID: mdl-38207081

ABSTRACT

PURPOSE: Successful implementation of precision education systems requires widespread adoption and seamless integration of new technologies with unique data streams that facilitate real-time performance feedback. This paper explores the use of sensor technology to quantify hands-on clinical skills. The goal is to shorten the learning curve through objective and actionable feedback. METHOD: A sensor-enabled clinical breast examination (CBE) simulator was used to capture force and video data from practicing clinicians (N = 152). Force-by-time markers from the sensor data and a machine learning algorithm were used to parse physicians' CBE performance into periods of search and palpation and then these were used to investigate distinguishing characteristics of successful versus unsuccessful attempts to identify masses in CBEs. RESULTS: Mastery performance from successful physicians showed stable levels of speed and force across the entire CBE and a 15% increase in force when in palpation mode compared with search mode. Unsuccessful physicians failed to search with sufficient force to detect deep masses ( F [5,146] = 4.24, P = .001). While similar proportions of male and female physicians reached the highest performance level, males used more force as noted by higher palpation to search force ratios ( t [63] = 2.52, P = .014). CONCLUSIONS: Sensor technology can serve as a useful pathway to assess hands-on clinical skills and provide data-driven feedback. When using a sensor-enabled simulator, the authors found specific haptic approaches that were associated with successful CBE outcomes. Given this study's findings, continued exploration of sensor technology in support of precision education for hands-on clinical skills is warranted.


Subject(s)
Palpation , Physicians , Humans , Male , Female , Mass Screening , Hand
20.
IEEE Trans Biomed Eng ; 71(6): 1958-1968, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38261510

ABSTRACT

OBJECTIVE: Robot-assisted minimally invasive surgery remains limited by the absence of haptic feedback, which surgeons routinely rely on to assess tissue stiffness. This limitation hinders surgeons' ability to identify and treat abnormal tissues, such as tumors, during robotic surgery. METHODS: To address this challenge, we developed a robotic tissue palpation device capable of rapidly and non-invasively quantifying the stiffness of soft tissues, allowing surgeons to make objective and data-driven decisions during minimally invasive procedures. We evaluated the effectiveness of our device by measuring the stiffness of phantoms as well as lung, heart, liver, and skin tissues obtained from both rats and swine. RESULTS: Results demonstrated that our device can accurately determine tissue stiffness and identify tumor mimics. Specifically, in swine lung, we determined elastic modulus (E) values of 9.1 ± 2.3, 16.8 ± 1.8, and 26.0 ± 3.6 kPa under different internal pressure of the lungs (PIP) of 2, 25, and 45 cmH2O, respectively. Using our device, we successfully located a 2-cm tumor mimic embedded at a depth of 5 mm in the lung subpleural region. Additionally, we measured E values of 33.0 ± 5.4, 19.2 ± 2.2, 33.5 ± 8.2, and 22.6 ± 6.0 kPa for swine heart, liver, abdominal skin, and muscle, respectively, which closely matched existing literature data. CONCLUSION/SIGNIFICANCE: Results suggest that our robotic palpation device can be utilized during surgery, either as a stand-alone or additional tool integrated into existing robotic surgical systems, to enhance treatment outcomes by enabling accurate intraoperative identification of abnormal tissue.


Subject(s)
Equipment Design , Minimally Invasive Surgical Procedures , Palpation , Robotic Surgical Procedures , Animals , Swine , Robotic Surgical Procedures/instrumentation , Robotic Surgical Procedures/methods , Rats , Palpation/instrumentation , Palpation/methods , Minimally Invasive Surgical Procedures/instrumentation , Minimally Invasive Surgical Procedures/methods , Phantoms, Imaging , Lung/surgery , Lung/physiology , Elastic Modulus , Liver/surgery , Liver/diagnostic imaging
SELECTION OF CITATIONS