Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.223
Filter
1.
Commun Biol ; 7(1): 538, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38714799

ABSTRACT

Human adolescent and adult skeletons exhibit sexual dimorphism in the pelvis. However, the degree of sexual dimorphism of the human pelvis during prenatal development remains unclear. Here, we performed high-resolution magnetic resonance imaging-assisted pelvimetry on 72 human fetuses (males [M]: females [F], 34:38; 21 sites) with crown-rump lengths (CRL) of 50-225 mm (the onset of primary ossification). We used multiple regression analysis to examine sexual dimorphism with CRL as a covariate. Females exhibit significantly smaller pelvic inlet anteroposterior diameters (least squares mean, [F] 8.4 mm vs. [M] 8.8 mm, P = 0.036), larger subpubic angle ([F] 68.1° vs. [M] 64.0°, P = 0.034), and larger distance between the ischial spines relative to the transverse diameters of the greater pelvis than males. Furthermore, the sacral measurements indicate significant sex-CRL interactions. Our study suggests that sexual dimorphism of the human fetal pelvis is already apparent at the onset of primary ossification.


Subject(s)
Fetus , Osteogenesis , Pelvis , Sex Characteristics , Humans , Female , Male , Pelvis/embryology , Pelvis/anatomy & histology , Pelvis/diagnostic imaging , Fetus/anatomy & histology , Fetus/diagnostic imaging , Magnetic Resonance Imaging , Pelvic Bones/anatomy & histology , Pelvic Bones/diagnostic imaging , Pelvic Bones/embryology , Crown-Rump Length , Fetal Development , Pelvimetry/methods
2.
Sci Rep ; 14(1): 12258, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38806582

ABSTRACT

With the recent increase in traffic accidents, pelvic fractures are increasing, second only to skull fractures, in terms of mortality and risk of complications. Research is actively being conducted on the treatment of intra-abdominal bleeding, the primary cause of death related to pelvic fractures. Considerable preliminary research has also been performed on segmenting tumors and organs. However, studies on clinically useful algorithms for bone and pelvic segmentation, based on developed models, are limited. In this study, we explored the potential of deep-learning models presented in previous studies to accurately segment pelvic regions in X-ray images. Data were collected from X-ray images of 940 patients aged 18 or older at Gachon University Gil Hospital from January 2015 to December 2022. To segment the pelvis, Attention U-Net, Swin U-Net, and U-Net were trained, thereby comparing and analyzing the results using five-fold cross-validation. The Swin U-Net model displayed relatively high performance compared to Attention U-Net and U-Net models, achieving an average sensitivity, specificity, accuracy, and dice similarity coefficient of 96.77%, of 98.50%, 98.03%, and 96.32%, respectively.


Subject(s)
Deep Learning , Fractures, Bone , Pelvic Bones , Humans , Fractures, Bone/diagnostic imaging , Pelvic Bones/diagnostic imaging , Pelvic Bones/injuries , Male , Female , Adult , Middle Aged , Algorithms , Aged , Pelvis/diagnostic imaging , Image Processing, Computer-Assisted/methods , Adolescent , Young Adult
3.
Zhongguo Gu Shang ; 37(5): 438-44, 2024 May 25.
Article in Chinese | MEDLINE | ID: mdl-38778525

ABSTRACT

OBJECTIVE: To compare the clinical efficacy of intraoperative slide rail CT combined with C-arm X-ray assistance and just C-arm for percutaneous screw in the treatment of pelvic posterior ring injury. METHODS: A retrospective analysis was performed on the patient data of 76 patients with posterior pelvic ring injury admitted to the Department of Orthopedic Trauma from December 2018 to February 2022. Among them, 39 patients in the CT group were treated with C-arm combined with slide rail CT-assisted inline fixation including 23 males and 16 females with an average age of (44.98±7.33) years old;and the other 37 patients in the C-arm group were treated with intraline fixation treatment under only C-arm fluoroscopy including 24 males and 13 females with an average age of (44.37±10.82) years old. Among them, 42 patients with anterior ring fractures were treated with percutaneous inferior iliac spines with internal fixation (INFIX) or suprapubic support screws to fix the anterior pelvic ring. Postoperative follow-up time, operation time, complications of the two groups were compared. Results of Matta reduction criteria, Majed efficacy evaluation, the CT grading and the rate of secondary surgical revision were compared. RESULTS: The nailing time of (32.63±7.33) min in CT group was shorter than that of (52.95±10.64) min in C-arm group (t=-9.739, P<0.05). The follow-up time between CT group (11.97±1.86) months and C-arm group (12.03±1.71) months were not statistically significant(P>0.05). The postoperative complication rates between two groups were not statistically significant (χ2=0.159, P>0.05). Results of Matta reduction criteria (Z=2.79, P<0.05), Majeed efficacy evaluation(Z=2.79, P<0.05), CT grading (Z=2.83, P<0.05) in CT group were better than those in C-arm group(P<0.05); the secondary surgical revision rate in the CT group was significantly lower than that in the C-arm group (χ2=5.641, P<0.05). CONCLUSION: Compared with traditional C-arm fluoroscopy, intraoperative slide rail CT combined with C-arm assisted percutaneous sacroiliac joint screw placement surgery has the characteristics of short operation time, high accuracy and safety, and significant decrease in postoperative secondary revision rate, and is one of the effective methods for re-establishing the stability of the posterior ring of pelvic fracture.


Subject(s)
Bone Screws , Fracture Fixation, Internal , Pelvic Bones , Sacroiliac Joint , Tomography, X-Ray Computed , Humans , Male , Female , Adult , Retrospective Studies , Middle Aged , Pelvic Bones/injuries , Pelvic Bones/surgery , Pelvic Bones/diagnostic imaging , Sacroiliac Joint/surgery , Sacroiliac Joint/injuries , Fracture Fixation, Internal/methods , Fractures, Bone/surgery
4.
BMC Musculoskelet Disord ; 25(1): 384, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755628

ABSTRACT

BACKGROUND: Customized 3D-printed pelvic implants with a porous structure have revolutionized periacetabular pelvic defect reconstruction after tumor resection, offering improved osteointegration, long-term stability, and anatomical fit. However, the lack of an established classification system hampers implementation and progress. METHODS: We formulated a novel classification system based on pelvic defect morphology and 3D-printed hemipelvis endoprostheses. It integrates surgical approach, osteotomy guide plate and prosthesis design, postoperative rehabilitation plans, and perioperative processes. RESULTS: Retrospectively analyzing 60 patients (31 males, 29 females), we classified them into Type A (15 patients: Aa = 6, Ab = 9), Type B (27 patients: Ba = 15, Bb = 12), Type C (17 patients). All underwent customized osteotomy guide plate-assisted tumor resection and 3D-printed hemipelvic endoprosthesis reconstruction. Follow-up duration was median 36.5 ± 15.0 months (range, 6 to 74 months). The mean operating time was 430.0 ± 106.7 min, intraoperative blood loss 2018.3 ± 1305.6 ml, transfusion volume 2510.0 ± 1778.1 ml. Complications occurred in 13 patients (21.7%), including poor wound healing (10.0%), deep prosthesis infection (6.7%), hip dislocation (3.3%), screw fracture (1.7%), and interface loosening (1.7%). VAS score improved from 5.5 ± 1.4 to 1.7 ± 1.3, MSTS-93 score from 14.8 ± 2.5 to 23.0 ± 5.6. Implant osseointegration success rate was 98.5% (128/130), with one Type Ba patient experiencing distal prosthesis loosening. CONCLUSION: The West China classification may supplement the Enneking and Dunham classification, enhancing interdisciplinary communication and surgical outcomes. However, further validation and wider adoption are required to confirm clinical effectiveness.


Subject(s)
Acetabulum , Bone Neoplasms , Printing, Three-Dimensional , Prosthesis Design , Humans , Female , Male , Retrospective Studies , Adult , Middle Aged , Acetabulum/surgery , Acetabulum/diagnostic imaging , Bone Neoplasms/surgery , Bone Neoplasms/diagnostic imaging , Young Adult , Osteotomy/methods , Plastic Surgery Procedures/methods , Plastic Surgery Procedures/instrumentation , Adolescent , Aged , Treatment Outcome , Postoperative Complications/etiology , Follow-Up Studies , Pelvic Bones/surgery , Pelvic Bones/diagnostic imaging
5.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38788049

ABSTRACT

CASE: A 25-year-old man sustained a stable lateral compression Type I (LC I) pelvic ring injury upon missing the landing of a downhill ski jump. He presented with painful voiding from a displaced bony fragment, partially impaling the bladder wall. With operative fixation of the fracture and urologic co-management, the patient had excellent outcomes at 1-year follow-up. CONCLUSION: We describe a rare urologic injury in the setting of an LC I pelvic ring injury. In the setting of an otherwise stable pelvic ring injury, careful review of imaging, detailed clinical history, and physical examination remain critical to optimizing patient outcomes.


Subject(s)
Pelvic Bones , Humans , Male , Adult , Pelvic Bones/injuries , Pelvic Bones/surgery , Pelvic Bones/diagnostic imaging , Urinary Bladder/surgery , Urinary Bladder/injuries , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging , Fracture Fixation, Internal/methods
6.
BMC Geriatr ; 24(1): 461, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38797837

ABSTRACT

BACKGROUND: Fragility fractures of the pelvis (FFPs) represent a significant health burden, particularly for the elderly. The role of sarcopenia, an age-related loss of muscle mass and function, in the development and impact of these fractures is not well understood. This study aims to investigate the prevalence and impact of osteoporosis and sarcopenia in patients presenting with FFPs. METHODS: This retrospective study evaluated 140 elderly patients with FFPs. The diagnosis of sarcopenia was assessed by psoas muscle area (PMA) and the height-adjusted psoas muscle index (PMI) measured on computed tomography (CT) scans. Clinical data, radiological findings and functional outcomes were recorded and compared with the presence or absence of sarcopenia and osteoporosis. RESULTS: Our study cohort comprised 119 female (85.0%) and 21 (15.0%) male patients. The mean age at the time of injury or onset of symptoms was 82.26 ± 8.50 years. Sarcopenia was diagnosed in 68.6% (n = 96) patients using PMA and 68.8% (n = 88) using PMI. 73.6% (n = 103) of our study population had osteoporosis and 20.0% (n = 28) presented with osteopenia. Patients with sarcopenia and osteoporosis had longer hospital stays (p < 0.04), a higher rate of complications (p < 0.048) and functional recovery was significantly impaired, as evidenced by a greater need for assistance in daily living (p < 0.03). However, they were less likely to undergo surgery (p < 0.03) and the type of FFP differed significantly (p < 0.04). There was no significant difference in mortality rate, pre-hospital health status, age or gender. CONCLUSION: Our study highlights the important role of sarcopenia in FFPs in terms of the serious impact on health and quality of life in elderly patients especially when osteoporosis and sarcopenia occur together. Identifying and targeting sarcopenia in older patients may be an important strategy to reduce pelvic fractures and improve recovery. Further research is needed to develop effective prevention and treatment approaches that target muscle health in the elderly.


Subject(s)
Sarcopenia , Humans , Sarcopenia/epidemiology , Male , Female , Retrospective Studies , Aged, 80 and over , Aged , Risk Factors , Pelvic Bones/injuries , Pelvic Bones/diagnostic imaging , Osteoporosis/epidemiology , Osteoporosis/complications , Psoas Muscles/diagnostic imaging , Osteoporotic Fractures/epidemiology , Tomography, X-Ray Computed/methods , Prevalence , Fractures, Bone/epidemiology , Fractures, Bone/complications
7.
Jt Dis Relat Surg ; 35(2): 455-461, 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38727129

ABSTRACT

Case reports of plexopathy after prostate cancer are usually neoplastic. Radiation-induced lumbosacral plexopathy and insufficiency fractures have clinical significance due to the need to differentiate them from tumoral invasions, metastases, and spinal pathologies. Certain nuances, including clinical presentation and screening methods, help distinguish radiation-induced plexopathy from tumoral plexopathy. This case report highlights the coexistence of these two rare clinical conditions. Herein, we present a 78-year-old male with a history of radiotherapy for prostate cancer who developed right foot drop, severe lower back and right groin pain, difficulty in standing up and walking, and tingling in both legs over the past month during remission. The diagnosis of lumbosacral plexopathy and pelvic insufficiency fracture was made based on magnetic resonance imaging, positron emission tomography, and electroneuromyography. The patient received conservative symptomatic treatment and was discharged with the use of a cane for mobility. Radiation-induced lumbosacral plexopathy following prostate cancer should be kept in mind in patients with neurological disorders of the lower limbs. Pelvic insufficiency fracture should also be considered if the pain does not correspond to the clinical findings of plexopathy. These two pathologies, which can be challenging to diagnose, may require surgical or complex management approaches. However, in this patient, conservative therapies led to an improvement in quality of life and a reduction in the burden of illness.


Subject(s)
Fractures, Stress , Lumbosacral Plexus , Prostatic Neoplasms , Radiation Injuries , Humans , Male , Prostatic Neoplasms/radiotherapy , Aged , Lumbosacral Plexus/injuries , Lumbosacral Plexus/radiation effects , Lumbosacral Plexus/pathology , Fractures, Stress/etiology , Fractures, Stress/diagnostic imaging , Radiation Injuries/etiology , Radiation Injuries/diagnostic imaging , Pelvic Bones/injuries , Pelvic Bones/pathology , Pelvic Bones/diagnostic imaging , Pelvic Bones/radiation effects , Peripheral Nervous System Diseases/etiology , Magnetic Resonance Imaging , Radiotherapy/adverse effects
8.
Gait Posture ; 111: 22-29, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38615565

ABSTRACT

BACKGROUND: Pelvic incidence (PI)-lumbar lordosis (LL) mismatch has a significant destabilizing effect on the center of gravity sway in the static standing position. However, the association between spinopelvic alignment and balance during gait in healthy volunteers is poorly understood. RESEARCH QUESTION: The degree of PI-LL mismatch and trunk anterior tilt in the static standing posture influences dynamic balance during gait. METHODS: In this study, 131 healthy volunteers were divided into two groups: harmonious group (PI - LL ≤ 10°; n = 91) and unharmonious group (PI - LL > 10°; n = 40). A two-point accelerometer system was used for gait analysis; accelerometers were attached to the pelvis and upper trunk to measure acceleration in the forward-backward, right-left, and vertical directions so that sagittal (front-back) deviation width, coronal (right-left) width, and vertical width and their ratios were calculated. Measurements were compared between the two groups, and correlations between alignment and accelerometer data were examined. RESULTS: The harmonious group showed a negative correlation between pelvic sagittal width and PI - LL, pelvic tilt (PT), and sagittal vertical axis (SVA) (correlation coefficient ρ = -0.42, -0.38, and -0.4, respectively), and a positive correlation between sagittal ratio and PI - LL (ρ = 0.35). The unharmonious group showed a positive correlation between pelvic sagittal width and PI and PT (ρ = 0.43 and 0.33, respectively) and between sagittal ratio and SVA (ρ = 0.32). The unharmonious group showed a positive correlation between upper trunk sagittal width and PI - LL and PT (ρ = 0.38 and 0.36, respectively). SIGNIFICANCE: The association between spinal alignment and gait parameters differs depending on the presence or absence of PI-LL mismatch. The degree of pelvic compensation and trunk anterior tilt during static standing were associated with unstable gait balance.


Subject(s)
Accelerometry , Gait , Lordosis , Pelvis , Postural Balance , Humans , Male , Adult , Female , Postural Balance/physiology , Gait/physiology , Pelvis/physiology , Lordosis/diagnostic imaging , Lordosis/physiopathology , Healthy Volunteers , Lumbar Vertebrae/diagnostic imaging , Young Adult , Gait Analysis , Middle Aged , Spine/physiology , Standing Position , Pelvic Bones/diagnostic imaging , Pelvic Bones/physiology , Radiography
9.
J Orthop Surg Res ; 19(1): 271, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38689343

ABSTRACT

BACKGROUND: Precise and minimally invasive closed reduction is the premise of minimally invasive internal fixation. This paper aims to explore the safety and efficacy of a robot-assisted fracture reduction system (RAFR) in the treatment of pelvic fractures and to analyze its clinical advantages and existing problems. METHODS: The RAFR system intelligently designed the optimal reduction path and target position based on a preoperative three-dimensional(3D) CT scan of the patient. The reduction robotic arm automatically reduced the affected hemipelvis according to the pre-planned reduction path. RESULTS: The average residual displacement was the 6.65 ± 3.59 mm. According to Matta's criteria, there were 7 excellent, 10 good, and 3 fair, and the excellent and good rate was 85%. No postoperative complications occurred. CONCLUSION: In our study, the RAFR system could complete accurate and minimally invasive closed reduction for most patients with unstable pelvic fractures, which could achieve good fracture reduction quality and short-term efficacy.


Subject(s)
Fractures, Bone , Pelvic Bones , Robotic Surgical Procedures , Humans , Pelvic Bones/injuries , Pelvic Bones/surgery , Pelvic Bones/diagnostic imaging , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging , Robotic Surgical Procedures/methods , Male , Female , Adult , Middle Aged , Young Adult , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Tomography, X-Ray Computed , Treatment Outcome , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/instrumentation , Aged
10.
Sci Rep ; 14(1): 9747, 2024 04 28.
Article in English | MEDLINE | ID: mdl-38679649

ABSTRACT

The study aimed to explore an extra-articular screw placement strategy in Stoppa approach. Radiographic data of patients who underwent pelvic computed tomography from January 2016 to June 2017 were imported into Materiaise's interactive medical image control system software for three-dimensional reconstruction. Superior and lower margins of acetabulum and ipsilateral pelvic brim could be observed simultaneously through inlet-obturator view. A horizontal line from superior acetabular margin intersected pelvic brim at point "A" and another vertical line from lower margin intersected pelvic brim at point "B" were drawn, respectively. Lengths form sacroiliac joint to "A" (a), "A" to "B" (b), and "B" to pubic symphysis (c) were measured. Patients were divided into four groups depending on gender and side difference of measured hemi-pelvis: male left, male right, female left, and female right. Lengths of adjacent holes (d) and spanning different holes (e) of different plates were also measured. Mean lengths of a, b, c in four groups were 40.94 ± 1.85 mm, 40.09 ± 1.93 mm, 41.78 ± 3.62 mm, and 39.77 ± 2.23 mm (P = 0.078); 40.65 ± 1.58 mm, 41.48 ± 1.64 mm, 40.40 ± 1.96 mm, and 40.66 ± 1.70 mm (P = 0.265); 57.03 ± 3.41 mm, 57.51 ± 3.71 mm, 57.84 ± 4.40 mm, and 59.84 ± 4.35 mm (P = 0.165), respectively. Mean d length of different plates was 12.23 mm. Average lengths spanning 1, 2, 3 and 4 holes were 19.33 mm, 31.58 mm, 43.80 mm, and 55.93 mm. Our data showed that zones a and c could be safely inserted three and four screws. Penetration into hip joint could be avoided when vacant 3-hole drilling was conducted in zone b. Fracture line in zone b could serve as a landmark for screw placement.


Subject(s)
Bone Screws , Imaging, Three-Dimensional , Tomography, X-Ray Computed , Humans , Female , Male , Imaging, Three-Dimensional/methods , Middle Aged , Adult , Fracture Fixation, Internal/methods , Aged , Pelvic Bones/surgery , Pelvic Bones/diagnostic imaging , Acetabulum/surgery , Acetabulum/diagnostic imaging , Sacroiliac Joint/surgery , Sacroiliac Joint/diagnostic imaging , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging
11.
Bone Joint J ; 106-B(5 Supple B): 3-10, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38688494

ABSTRACT

Aims: The aim of this study was to investigate whether anterior pelvic plane-pelvic tilt (APP-PT) is associated with distinct hip pathomorphologies. We asked: is there a difference in APP-PT between young symptomatic patients being evaluated for joint preservation surgery and an asymptomatic control group? Does APP-PT vary among distinct acetabular and femoral pathomorphologies? And does APP-PT differ in symptomatic hips based on demographic factors? Methods: This was an institutional review board-approved, single-centre, retrospective, case-control, comparative study, which included 388 symptomatic hips in 357 patients who presented to our tertiary centre for joint preservation between January 2011 and December 2015. Their mean age was 26 years (SD 2; 23 to 29) and 50% were female. They were allocated to 12 different morphological subgroups. The study group was compared with a control group of 20 asymptomatic hips in 20 patients. APP-PT was assessed in all patients based on supine anteroposterior pelvic radiographs using validated HipRecon software. Values in the two groups were compared using an independent-samples t-test. Multiple regression analysis was performed to examine the influences of diagnoses and demographic factors on APP-PT. The minimal clinically important difference (MCID) for APP-PT was defined as > 1 SD. Results: There were no significant differences in APP-PT between the control group and the overall group (1.1° (SD 3.0°; -4.9° to 5.9°) vs 1.8° (SD 3.4°; -6.9° to 13.2°); p = 0.323). Acetabular retroversion and overcoverage groups showed higher mean APP-PTs compared with the control group (p = 0.001 and p = 0.014) and were the only diagnoses with a significant influence on APP-PT in the stepwise multiple regression analysis. All differences were below the MCID. The age, sex, height, weight, and BMI showed no influence on APP-PT. Conclusion: APP-PT showed no radiologically significant variation across different pathomorphologies of the hip in patients being assessed for joint-preserving surgery.


Subject(s)
Acetabulum , Humans , Female , Acetabulum/diagnostic imaging , Male , Adult , Retrospective Studies , Case-Control Studies , Young Adult , Femur/diagnostic imaging , Hip Joint/diagnostic imaging , Hip Joint/physiopathology , Radiography , Pelvic Bones/diagnostic imaging
12.
Injury ; 55(6): 111520, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38594084

ABSTRACT

INTRODUCTION: Fragility fractures without significant trauma of the pelvic ring in older patients have an increasing incidence due to demographic change. Influencing factors other than osteoporotic bone quality that lead to an insufficiency fracture are not yet known. However, it is suspected that the pelvic tilt (PT) has an effect on the development of such an insufficiency fracture. This study explores the influence of the PTs in patients with insufficiency fractures of the posterior pelvic ring. MATERIALS AND METHODS: A total of 49 geriatric patients with fragility fractures of the pelvic ring were treated at a university hospital level-1 trauma center during a period between February and December 2023, and their fractures were classified according to the FFP classification of Rommens and Hofmann. Complete sets of computer tomography (CT) and radiological images were available to determine the PT angle of the patients. RESULTS: 34 FFP type 2 and 15 FFP type 3 classified patients were included in the study. Significant difference was seen in the pelvic tilt (PT) angle between the patient group with insufficiency fractures (n= 49; mean age: 78.02 ± 11.80) and the control group with lumbago patients (n= 53; mean age: 69.23 ± 11.23). The PT was significantly higher in the patients with insufficiency fractures (25.74° ± 4.76; p⁎⁎⁎⁎ ≤ 0.0001). CONCLUSIONS: The study demonstrates a significant extension of the PT angle of individuals with insufficiency fractures when compared to those with lumbago. The result suggests a potential association between pelvic tilt and fracture susceptibility. TRIAL REGISTRATION: A retrospective study about the influence of sagittal balance of the spine on insufficiency fractures of the posterior pelvic ring measured by the "pelvic tilt angle", DRKS00032120. Registered 20th June 2023 - Prospectively registered. Trial registration number DRKS00032120.


Subject(s)
Fractures, Stress , Pelvic Bones , Sacrum , Tomography, X-Ray Computed , Humans , Female , Aged , Male , Pelvic Bones/injuries , Pelvic Bones/diagnostic imaging , Aged, 80 and over , Fractures, Stress/diagnostic imaging , Fractures, Stress/epidemiology , Fractures, Stress/physiopathology , Sacrum/diagnostic imaging , Sacrum/injuries , Prevalence , Osteoporotic Fractures/physiopathology , Osteoporotic Fractures/epidemiology , Osteoporotic Fractures/diagnostic imaging , Retrospective Studies , Spinal Fractures/physiopathology , Spinal Fractures/diagnostic imaging , Spinal Fractures/epidemiology , Spinal Fractures/complications , Middle Aged , Posture/physiology
13.
Injury ; 55(6): 111518, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38614834

ABSTRACT

INTRODUCTION: Post-operative pelvic & acetabular fixation patients are conventionally imaged using 3-view radiographs (AP, inlet and outlet). The efficacy of such radiographs is inconsistent due to technical difficulties capturing an adequate view, often necessitating repeat radiographs and therefore increasing radiation exposure. Radiographs can be difficult to interpret, limiting the assessment of fracture reduction and fixation, especially with respect to metalwork positioning around articular surfaces. Traditionally, post-operative pelvic & acetabular fixation patients undergo repeat 3-view radiographs post-operatively, at 6 weeks, followed by at 3, 6, 12, 18 and 24 months. We propose a new pathway, in which patients have one low-dose pelvic CT immediately post-operatively, followed by one radiograph (AP pelvis) at the same time points. METHODS: A new pelvic CT protocol was created to provide high quality 3D imaging whilst delivering a 5 times lower radiation dose (compared to normal pelvic CT). Data for all pelvic radiographs and CTs between January 2021 and March 2022 was exported. Using dose area product values, effective radiation dose and attributable lifetime cancer risk were calculated. RESULTS: There were 42 patients included in the analysis (age range 15 to 87).The average effective dose for the 3-view pelvic X-rays was 0.6mSv (range 0.2 to 2.8mSv), and 1.1mSv (range 0.5 to 2.2mSv) for the low-dose pelvic CT. Traditional 7 × 3-view post-operative radiographs: 7 × 0.6mSv = 4.2mSv (corresponding to 1 in 11,000 cancer risk) Low dose post-operative CT and 6 × 1-view radiographs: 1.1mSv + (6 × 0.6mSv / 3) = 2.3mSv (corresponding to 1 in 20,000 cancer risk) CONCLUSION: Low-dose CT scanning (in conjunction with 1-view radiographs) is an effective and safe imaging modality in the post-operative assessment of pelvic & acetabular fracture fixation, conferring a lower radiation burden, easier logistics, and higher quality images when compared to the traditional pathway of 3-view radiographs.


Subject(s)
Acetabulum , Fracture Fixation, Internal , Fractures, Bone , Pelvic Bones , Radiation Dosage , Tomography, X-Ray Computed , Humans , Acetabulum/surgery , Acetabulum/diagnostic imaging , Acetabulum/injuries , Female , Male , Middle Aged , Adult , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Aged , Pelvic Bones/diagnostic imaging , Pelvic Bones/injuries , Pelvic Bones/surgery , Adolescent , Aged, 80 and over , Fracture Fixation, Internal/methods , Young Adult , Imaging, Three-Dimensional , Postoperative Care/methods , Retrospective Studies , Postoperative Period , Radiation Exposure
14.
BMC Surg ; 24(1): 105, 2024 Apr 13.
Article in English | MEDLINE | ID: mdl-38614998

ABSTRACT

BACKGROUND: Most 3D-printed guiding templates require dissection of soft tissues to match the corresponding surfaces of the guiding templates. This study sought to explore the accuracy and acceptability of the novel 3D printed individualized guiding templates based on cutaneous fiducial markers in minimally invasive screw placement for pelvic fractures. METHODS: The printed template was tested on five high-fidelity biomimetic phantom models of the bony pelvis and its surrounding soft tissues as well as on two fresh frozen cadavers. Four cutaneous fiducial markers were transfixed on each phantom model prior to performing CT scans to reconstruct their 3D models. Personalized templates for guiding screw insertion were designed based on the positions of the fiducial markers and virtually planned target screw channels after scanning, followed by 3D printing of the guide. Phase 1 consisted of five expert surgeons inserting one anterograde supra-pubic screw and one sacroiliac screw percutaneously into each phantom model using the 3D-printed guide. The deviation of screw positions between the pre-operative planned and post-operative actual ones was measured after registering their 3D modelling. A Likert scale questionnaire was completed by the expert surgeons to assess their satisfaction and acceptability with the guiding template. Phase 2 consisted of repeating the same procedures on the fresh frozen cadavers in order to demonstrate face, content and concurrent validity. RESULTS: In Phase 1, all ten screws were successfully implanted with the assistance of the guiding template. Postoperative CT scans confirmed that all screws were safely positioned within the bony pelvic channels without breaching the far cortex. The mean longitudinal deviation at the bony entry point and screw tip between the pre-operative planned and post-operative actual screw paths were 2.83 ± 0.60 mm and 3.12 ± 0.81 mm respectively, with a mean angular deviation of 1.25 ± 0.41°. Results from the Likert questionnaire indicated a high level of satisfaction for using the guiding template among surgeons. In Phase 2, results were similar to those in Phase 1. CONCLUSIONS: The 3D-printed guiding template based on cutaneous fiducial markers shows potential for assisting in the accurate insertion of percutaneous screws in the pelvis.


Subject(s)
Pelvic Bones , Surgeons , Humans , Fiducial Markers , Pelvis , Pelvic Bones/diagnostic imaging , Pelvic Bones/surgery , Cadaver
15.
Eur J Orthop Surg Traumatol ; 34(4): 2205-2211, 2024 May.
Article in English | MEDLINE | ID: mdl-38554164

ABSTRACT

Pelvic fixation is commonly used in correcting pelvic obliquity in pediatric patients with neuromuscular scoliosis and in preserving stability in adult patients with lumbosacral spondylolisthesis or instances of traumatic or osteoporotic fracture. S2-alar-iliac screws are commonly used in this role and have been proposed to reduce implant prominence when compared to traditional pelvic fusion utilizing iliac screws. The aim of this technical note is to describe a technique for robotically navigated placement of S2-alar-iliac screws in pediatric patients with neuromuscular scoliosis, which (a) minimizes the significant exposure needed to identify a bony start point, (b) aids in instrumenting the irregular anatomy often found in patients with neuromuscular scoliosis, and (c) allows for greater precision than traditional open or fluoroscopic techniques. We present five cases that underwent posterior spinal fusion to the pelvis with this technique that demonstrate the safety and efficacy of this procedure.


Subject(s)
Bone Screws , Robotic Surgical Procedures , Scoliosis , Spinal Fusion , Humans , Scoliosis/surgery , Spinal Fusion/methods , Spinal Fusion/instrumentation , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Female , Child , Adolescent , Male , Ilium/surgery , Pelvic Bones/surgery , Pelvic Bones/diagnostic imaging , Pelvic Bones/injuries , Sacrum/surgery , Sacrum/diagnostic imaging , Neuromuscular Diseases/complications , Neuromuscular Diseases/surgery , Lumbar Vertebrae/surgery , Lumbar Vertebrae/diagnostic imaging , Surgery, Computer-Assisted/methods
16.
J Orthop Trauma ; 38(6): 299-305, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38470146

ABSTRACT

OBJECTIVES: To estimate the prevalence of suboptimal fluoroscopy of sacral outlet images due to anatomic and equipment dimensions. Pelvic retroversion is hypothesized to mitigate this issue. DESIGN: In silico simulations using retrospectively collected computed tomography (CT) data from human patients. SETTING: Level I trauma center. PATIENT SELECTION CRITERIA: Adults with OTA/AO 61 pelvic ring disruptions treated with posterior pelvic fixation between July and December 2021. OUTCOME MEASURES AND COMPARISONS: C-arm tilt angles required to obtain 3 optimal fluoroscopic sacral outlet images, defined as vectors from pubic symphysis to S2 and parallel to the first and second sacral neural foramina, were calculated from sagittal CT images. A suboptimal view was defined as collision of the C-arm radiation source or image intensifier with the patient/operating table at the required tilt angle simulated using the dimensions of 5 commercial C-arm models and trigonometric calculations. Incidence of suboptimal outlet views and pelvic retroversion necessary to obtain optimal views without collision, which may be obtained by placement of a sacral bump, was determined for each view for all patients and C-arm models. RESULTS: CT data from 72 adults were used. Collision between patient and C-arm would occur at the optimal tilt angle for 17% of simulations and at least 1 view in 68% of patients. Greater body mass index was associated with greater odds of suboptimal imaging (standard outlet: odds ratio [OR] 0.84, confidence interval [CI] 0.79-0.89, P < 0.001; S1: OR 0.91, CI 0.87-0.97, P = 0.002; S2: OR 0.85, CI 0.80-0.91, P < 0.001). S1 anterior sacral slope was associated with suboptimal S1 outlet views (OR 1.12, Cl 1.07-1.17, P < 0.001). S2 anterior sacral slope was associated with suboptimal standard outlet (OR 1.07, Cl 1.02-1.13, P = 0.004) and S2 outlet (OR 1.16, Cl 1.09-1.23, P < 0.001) views. Retroversion of the pelvis 15-20 degrees made optimal outlet views possible without collision in 95%-99% of all simulations, respectively. CONCLUSIONS: Suboptimal outlet imaging of the sacrum is associated with greater body mass index and sacral slope at S1 and S2. Retroversion of the pelvis by 15-20 degrees with a bump under the distal sacrum may offer a low-tech solution to ensure optimal fluoroscopic imaging for percutaneous fixation of the posterior pelvic ring. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Pelvic Bones , Sacrum , Tomography, X-Ray Computed , Humans , Sacrum/diagnostic imaging , Fluoroscopy , Male , Female , Pelvic Bones/diagnostic imaging , Retrospective Studies , Adult , Middle Aged , Tomography, X-Ray Computed/methods , Computer Simulation , Fractures, Bone/diagnostic imaging , Aged
17.
Arch Orthop Trauma Surg ; 144(5): 1945-1953, 2024 May.
Article in English | MEDLINE | ID: mdl-38554202

ABSTRACT

INTRODUCTION: The optimal positioning of the hip prosthesis components is influenced by the mobility and balance of the spine. The present study classifies patients with pathology of the spino-pelvic-hip complex, showing possible methods of preventing hip dislocations after arthroplasty. HYPOTHESIS: Hip-Spine Classification helps arthroplasty surgeons to implant components in more patient-specific position. MATERIALS AND METHODS: The group of 100 patients treated with total hip arthroplasty. Antero-posterior (AP) X-rays of the pelvis in a standing position, lateral spine (standing and sitting) and AP of the pelvis (supine after the procedure) were analyzed. We analyzed a change in sacral tilt value when changing from standing to sitting (∆SS), Pelvic Incidence (PI), Lumbar Lordosis (LL) Mismatch, sagittal lumbar pelvic balance (standing position). Patients were classified according to the Hip-Spine Classification. Postoperatively, the inclination and anteversion of the implanted acetabular component were measured. RESULTS: In our study 1 A was diagnosed in 61% of all cases, 1B in 18%, 2 A in 16%, 2B in 5%. 50 out of 61 (82%) in group 1 A were placed within the Levinnek "safe zone". In 1B, 2 A, 2B, the position of the acetabular component was influenced by both the spinopelvic mobility and sagittal spinal balance. The mean inclination was 43.35° and the anteversion was 17.4°. CONCLUSIONS: Categorizing patients according to Hip-Spine Classification one can identify possible consequences the patients at risk. Pathology of the spino-pelvic-hipcomplex can lead to destabilization or dislocation of hip after surgery even though implanted according to Lewinnek's indications. Our findings suggest that Lewinnek safe zone should be abandoned in favor of the concept of functional safe zones.


Subject(s)
Arthroplasty, Replacement, Hip , Humans , Arthroplasty, Replacement, Hip/methods , Male , Female , Aged , Middle Aged , Pelvic Bones/diagnostic imaging , Pelvis/diagnostic imaging , Lumbar Vertebrae/surgery , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/physiopathology , Aged, 80 and over , Spine/surgery , Spine/diagnostic imaging , Hip Prosthesis , Hip Joint/diagnostic imaging , Hip Joint/physiopathology , Hip Joint/surgery , Hip Dislocation/diagnostic imaging , Hip Dislocation/prevention & control , Hip Dislocation/surgery , Hip Dislocation/physiopathology , Adult
18.
Arch Orthop Trauma Surg ; 144(5): 2381-2389, 2024 May.
Article in English | MEDLINE | ID: mdl-38554208

ABSTRACT

INTRODUCTION: This study aimed to investigate the accuracy of cup position and assess the changes in pelvic tilt during primary total hip arthroplasty (THA) in the lateral decubitus position using a new computed tomography (CT)-based navigation system with augmented reality (AR) technology. MATERIALS AND METHODS: There were 37 cementless THAs performed using a CT-based navigation system with AR technology in the lateral decubitus position and 63 cementless THAs performed using manual implant techniques in the lateral decubitus position in this retrospective study. Postoperative cup radiographic inclination and anteversion were measured using postoperative CT, and the proportion of hips within Lewinnek's safe zone was analyzed and compared between the two groups. The mean absolute values of navigation error were assessed. Intraoperative pelvic tilt angles were also recorded using navigation system. RESULTS: The percentage of cups inside Lewinnek's safe zone was 100% in the navigation group and 35% in the control group (p < 0.001). The mean absolute values of navigation error in inclination and anteversion were 2.9° ± 2.1° and 3.3° ± 2.4°, respectively. The mean abduction angle of the pelvis was 5.1° ± 4.8° after placing the patients in the lateral decubitus position and 4.1° ± 6.0° after cup placement. The mean posterior tilt angle was 6.8° ± 5.1° after placing the patients in the lateral decubitus position and 9.3° ± 5.9° after cup placement. The mean internal rotation angle was 14.8° ± 7.4° after cup placement. There were no correlations between the navigation error in inclination or anteversion and the absolute values of changes of the pelvic tilt angle at any phase. CONCLUSIONS: Although progressive pelvic motion occurred in THA in the lateral decubitus position, especially during cup placement, the CT-based navigation system with AR technology improved cup placement accuracy.


Subject(s)
Arthroplasty, Replacement, Hip , Patient Positioning , Tomography, X-Ray Computed , Humans , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Female , Male , Tomography, X-Ray Computed/methods , Retrospective Studies , Middle Aged , Aged , Patient Positioning/methods , Hip Prosthesis , Augmented Reality , Surgical Navigation Systems , Surgery, Computer-Assisted/methods , Pelvis/diagnostic imaging , Pelvic Bones/diagnostic imaging , Pelvic Bones/surgery
19.
J Surg Res ; 296: 310-315, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38306936

ABSTRACT

INTRODUCTION: Although low-energy pelvic fractures seldom present with significant hemorrhage, early recognition of at-risk patients is essential. We aimed to identify predictors of transfusion requirements in this cohort. METHODS: A 7-y retrospective chart review was performed. Low-energy mechanism was defined as falls of ≤5 feet. Fracture pattern was classified using the Orthopedic Trauma Association/Arbeitsgemeinschaft für Osteosynthesefragen system as A, B, or C. Primary outcome was transfusion of ≥2 units of packed red blood cells in the first 48 h. Univariable analysis and logistic regression analysis were performed. A P value ≤0.05 was considered significant. RESULTS: Five hundred forty six patients were included with median (interquartile range) age of 86 (79-91) and median (interquartile range) Injury Severity Score of 5 (4-8). Five hundred forty one (99%) had type A fractures. Twenty six (5%) had the primary outcome and 17 (3%) died. Logistic regression found that systolic blood pressure <100 mmHg at any time in the Emergency Department, Injury Severity Score, and pelvic angiography were predictors of the primary outcome. Seventeen percent of those who had the primary outcome died compared with 2% who did not (P = 0.0004). Three hundred sixty four (67%) received intravenous contrast for computerized tomography scans and of these, 44 (12%) had contrast extravasation (CE). CE was associated with the primary outcome but not mortality. CONCLUSIONS: Hypotension at any time in the Emergency Department and CE on computerized tomography predicted transfusion of ≥2 units packed red blood cells in the first 48 h in patients with low-energy pelvic fractures.


Subject(s)
Fractures, Bone , Hypotension , Pelvic Bones , Humans , Retrospective Studies , Pelvic Bones/diagnostic imaging , Pelvic Bones/injuries , Fractures, Bone/diagnostic imaging , Fractures, Bone/therapy , Fractures, Bone/complications , Hypotension/etiology , Extravasation of Diagnostic and Therapeutic Materials/diagnostic imaging , Extravasation of Diagnostic and Therapeutic Materials/epidemiology , Extravasation of Diagnostic and Therapeutic Materials/etiology , Emergency Service, Hospital , Injury Severity Score , Blood Transfusion , Tomography
20.
Unfallchirurgie (Heidelb) ; 127(4): 273-282, 2024 Apr.
Article in German | MEDLINE | ID: mdl-38302736

ABSTRACT

Insufficiency fractures of the pelvis have increased in recent years, primarily due to the demographic change and the incidence will continue to rise. In addition to conventional X­rays, the diagnostics always require slice imaging. Unlike high-energy trauma magnetic resonance imaging (MRI) plays an important role in insufficiency fractures. Once the fracture has been diagnosed, in addition to the extent of instability in the anterior and posterior pelvic rings, the pain symptoms are crucial for the decision on surgical treatment. The basic principle is to stabilize as little as possible but as much as necessary. There are currently a variety of procedures that can be applied as a minimally invasive procedure, especially for the often slightly or displaced insufficiency fractures. The decisive factor for treatment is that it enables early mobilization of the patients. All of these measures must be accompanied by thorough diagnostics of osteoporosis and the appropriate treatment.


Subject(s)
Fractures, Stress , Osteoporosis , Pelvic Bones , Humans , Fractures, Stress/diagnosis , Pelvic Bones/diagnostic imaging , Pelvis/injuries , Osteoporosis/complications , Radiography
SELECTION OF CITATIONS
SEARCH DETAIL
...