Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.958
Filter
1.
Eur Rev Med Pharmacol Sci ; 28(8): 3165-3175, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38708475

ABSTRACT

OBJECTIVE: Periprosthetic fractures following total knee replacement are rare but challenging. The goal of the treatment is to achieve the most stable fixation that allows early mobilization. Therefore, the aim of this study was to evaluate the biomechanical results of the use of different fixation systems in the treatment of distal femur periprosthetic fractures with finite element analysis. MATERIALS AND METHODS: A total knee prosthesis was implanted in Sawbone femur models. A transverse fracture line was created in the supracondylar region and was fixed in four different groups. In group 1, fracture line fixation was fixed using retrograde intramedullary nailing. In group 2, fixation was applied using a lateral anatomic distal femoral. In group 3, in addition to the fixation made in group 1, a lateral anatomic distal femoral plate was used. In group 4, in addition to the fixation made in group 2, a 3.5 mm Limited Contact Dynamic Compression Plate (LC-DCP) was applied medially. Computed Tomography (CT) scans were taken of the created models and were converted to three-dimensional models. Axial and rotational loading forces were applied to all the created models. RESULTS: The least deformation with axial loading was observed in the double plate group. Group 3 was determined to be more advantageous against rotational forces. The greatest movement in the fracture line was found in group 2. The application of the medial plate was determined to reduce the tension on the lateral plate and increase stability in the fracture line. CONCLUSIONS: Combining a lateral anatomic plate with intramedullary nailing or a medial plate was seen to be biomechanically more advantageous than using a lateral plate or intramedullary nailing alone in the treatment of distal femoral periprosthetic fractures.


Subject(s)
Arthroplasty, Replacement, Knee , Bone Nails , Bone Plates , Femoral Fractures , Finite Element Analysis , Fracture Fixation, Intramedullary , Periprosthetic Fractures , Arthroplasty, Replacement, Knee/adverse effects , Femoral Fractures/surgery , Humans , Periprosthetic Fractures/surgery , Fracture Fixation, Intramedullary/instrumentation , Bone Screws , Biomechanical Phenomena
2.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38728527

ABSTRACT

CASE: A 79-year-old woman presented with a periprosthetic fracture 8 years after a total knee arthroplasty (TKA). Radiographs demonstrated tibial implant loosening with severe osteolysis. A high-grade osteosarcoma around the prosthesis was diagnosed, and a supracondylar femoral amputation was performed. After 2 years, no complications have occurred. CONCLUSIONS: A malignant tumor around a TKA is extremely rare. Surgeons should remain vigilant with patients who present with rapidly progressive or very aggressive implant loosening with osteolysis. Owing to its complexity and potentially devastating prognosis, treatment should be guided by a specialist multidisciplinary team. Complex limb salvage procedures or amputation is usually required.


Subject(s)
Arthroplasty, Replacement, Knee , Bone Neoplasms , Osteosarcoma , Humans , Female , Osteosarcoma/surgery , Osteosarcoma/diagnostic imaging , Arthroplasty, Replacement, Knee/adverse effects , Aged , Bone Neoplasms/surgery , Bone Neoplasms/diagnostic imaging , Amputation, Surgical , Periprosthetic Fractures/etiology , Periprosthetic Fractures/surgery , Periprosthetic Fractures/diagnostic imaging , Prosthesis Failure
3.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38728526

ABSTRACT

CASE: A 58-year-old woman with medical history of a left total hip arthroplasty performed by the direct anterior (DA) approach 2 years prior presented with left hip pain. She was found to have sustained a transverse Vancouver C periprosthetic femur fracture and an unstable periprosthetic pelvic fracture. CONCLUSIONS: This patient's case represents a previously not reported injury about a total hip arthroplasty-with disruption distal to the femoral implant and proximal to the acetabular implant, with the implant-to-bone interface unaffected. This case may guide future treatment of similar injuries.


Subject(s)
Arthroplasty, Replacement, Hip , Periprosthetic Fractures , Humans , Female , Arthroplasty, Replacement, Hip/adverse effects , Middle Aged , Periprosthetic Fractures/surgery , Periprosthetic Fractures/etiology , Periprosthetic Fractures/diagnostic imaging , Femoral Fractures/surgery , Femoral Fractures/diagnostic imaging , Femoral Fractures/etiology
5.
Orthop Clin North Am ; 55(3): 311-321, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38782503

ABSTRACT

This report provides an updated analysis for patients with osteoporosis following total hip arthroplasty (THA). The comorbidities of alcohol abuse, chronic kidney disease, cerebrovascular disease, obesity, and rheumatoid arthritis continue to be significant risk factors for periprosthetic femur fracture (PPFFx) and aseptic loosening in the population with osteoporosis. Patients with dual-energy x-ray absorptiometric (DEXA) scans were at risk for PPFFx regardless of femoral fixation method, and patients with DEXA scans with cementless fixation were at risk of aseptic loosening after THA. The patient population with severe osteoporosis may have higher risks for aseptic loosening and PPFFx than previously recognized.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Osteoporosis , Periprosthetic Fractures , Prosthesis Failure , Humans , Arthroplasty, Replacement, Hip/adverse effects , Periprosthetic Fractures/etiology , Periprosthetic Fractures/epidemiology , Osteoporosis/etiology , Osteoporosis/complications , Risk Factors , Femoral Fractures/surgery , Femoral Fractures/etiology , Female , Male , Aged , Hip Prosthesis/adverse effects , Absorptiometry, Photon , Middle Aged
6.
J Orthop Surg Res ; 19(1): 303, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38769547

ABSTRACT

INTRODUCTION: The incidence of periprosthetic distal femur fractures (PDFF) is increasing as the number of total knee replacements becomes more common. This study compared the demographics, fracture characteristics, treatment, and outcomes of periprosthetic versus native distal femur fractures (NDFF). MATERIALS AND METHODS: This was a retrospective cohort study of patients ≥ 18 who underwent surgical fixation of NDFF or PDFF from 2012 to 2020 at a level-1 trauma center. The main variables collected included demographics, AO/OTA fracture classification, fixation construct, concomitant fractures, polytrauma rates, bone density, and reduction quality. Primary outcomes were unexpected return to the operating room (UROR), hospital length of stay, and quality of reduction. T-tests, Fisher's exact tests, and multivariate analyses were used for statistical analysis. RESULTS: 209 patients were identified, including 70 PDFF and 139 NDFF. PDFF patients were elderly females (81%) with isolated (80%) and comminuted (85%) 33 A.3 (71%) fractures. NDFF patients included 53% females, were commonly middle-aged, and displayed comminuted (92%) 33 C.2 fractures. 48% of NDFF patients had concomitant fractures. Intramedullary nailing was the primary fixation for both groups, followed by nail-plate combination (37%) for PDFF and lateral locking plates (21%) for NDFF. NDFF patients experienced significantly longer hospital stays, higher UROR rates, and worse quality of reduction (p < 0.05). PDFF patients had a significantly greater prevalence of low bone density (p < 0.05). CONCLUSION: PDFF occur as isolated injuries with significant metaphyseal comminution in elderly females with low bone quality. NDFF commonly occurs in younger patients with less metaphyseal comminution and concomitant fractures. Intramedullary nailing was the most common treatment for both groups, although preference for nail-plate combination fixation is increasing. NDFF type 33 C fractures are at greater risk of UROR.


Subject(s)
Femoral Fractures , Fracture Fixation, Intramedullary , Periprosthetic Fractures , Humans , Female , Male , Retrospective Studies , Femoral Fractures/surgery , Aged , Middle Aged , Periprosthetic Fractures/etiology , Periprosthetic Fractures/surgery , Periprosthetic Fractures/epidemiology , Fracture Fixation, Intramedullary/methods , Aged, 80 and over , Arthroplasty, Replacement, Knee/adverse effects , Length of Stay/statistics & numerical data , Treatment Outcome , Adult , Cohort Studies , Femoral Fractures, Distal
7.
Clin Orthop Surg ; 16(2): 294-302, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38562643

ABSTRACT

Background: There are few reports on the revision or reintervention of reverse total shoulder arthroplasty (RTSA) in South Korea. The purpose of this study was to evaluate the true incidence of complications and reintervention of RTSA and clinical and radiological outcomes based on our 14-year experience in RTSA in a Korean population. Methods: Between March 2008 and June 2022, 412 consecutive cases of RTSA were performed in 388 patients with an average age of 74.4 years at our institute. Excluding 23 patients lost to follow-up, 365 patients (373 shoulders including 8 bilateral cases) who underwent primary RTSA with more than 6 months of follow-up were enrolled in this study. We evaluated those who had complications or reintervention including revision RTSA for failed RTSA. Patient charts were reviewed, and clinical outcomes including clinical scores, complications, and reintervention and radiologic outcomes were evaluated at the last follow-up. Results: Among the 373 shoulders that underwent primary RTSA, complications were found in 50 patients (13.94%, 10 men and 40 women with a mean age of 75.9 ± 6.7 years [range, 51-87 years]). The causes of complications were as follows: 13 acromion, coracoid, or scapular spine fractures, 10 loosening (glenoid: 5, humeral stem: 5), 5 infections, 4 periprosthetic fractures, 2 instability, 2 neurologic complications, and 14 miscellaneous complications. Twenty patients (5.63%, 4 men and 16 women with a mean age of 74.2 ± 8.2 years [range, 51-87 years]) underwent reintervention. The interval to the first reintervention was 27.8 ± 23.1 months (range, 0.1-78 months). The causes of reintervention (20 cases) were 8 loosening (glenoid: 4, humeral stem: 4), 5 infections, 5 fractures, and 2 instability. Among them, 15 component revisions (4.02%) were performed. At the last follow-up, American Shoulder and Elbow Surgeons, University of California at Los Angeles, and Simple Shoulder Test scores were improved from 25.4, 12.4, and 1.6 preoperatively to 40.4, 16.2, and 3.2, respectively. Forward flexion (48° to 87°), abduction (52° to 79°), external rotation (18° to 22°), and internal rotation (buttock to L2) were improved. Conclusions: After primary RTSA in a Korean population, the complication, reintervention, and revision rates were 13.94%, 5.63%, and 4.02%, respectively. Careful evaluation of the complications and adequate treatments should be performed.


Subject(s)
Arthroplasty, Replacement, Shoulder , Periprosthetic Fractures , Shoulder Joint , Male , Humans , Female , Aged , Aged, 80 and over , Arthroplasty, Replacement, Shoulder/adverse effects , Shoulder Joint/diagnostic imaging , Shoulder Joint/surgery , Treatment Outcome , Periprosthetic Fractures/etiology , Scapula , Retrospective Studies , Range of Motion, Articular , Reoperation/adverse effects
8.
PLoS One ; 19(4): e0300956, 2024.
Article in English | MEDLINE | ID: mdl-38630711

ABSTRACT

Increasing the stem size during surgery is associated with a higher incidence of intraoperative periprosthetic fractures in cementless total hip arthroplasty with fully coated tapered wedge stems, especially in femurs of Dorr type A. If in contrast a stem is implanted and sufficient primary stability is not achieved, such preventing successful osseointegration due to increased micromotions, it may also fail, especially if the stem is undersized. Stem loosening or periprosthetic fractures due to stem subsidence can be the consequence. The adaptation of an established stem design to femurs of Dorr type A by design modifications, which increase the stem width proximally combined with a smaller stem tip and an overall shorter stem, might reduce the risk of distal locking of a proximally inadequately fixed stem and provide increased stability. The aim of this study was to investigate whether such a modified stem design provides improved primary stability without increasing the periprosthetic fracture risk compared to the established stem design. The established (Corail, DePuy Synthes, Warsaw, IN, US) and modified stem designs (Emphasys, DePuy Synthes, Warsaw, IN, US) were implanted in cadaveric femur pairs (n = 6 pairs) using the respective instruments. Broaching and implantation forces were recorded and the contact areas between the prepared cavity and the stem determined. Implanted stems were subjected to two different cyclic loading conditions according to ISO 7206-4 using a material testing machine (1 Hz, 600 cycles @ 80 to 800 N, 600 cycles @ 80 to 1600 N). Translational and rotational relative motions between stem and femur were recorded using digital image correlation. Broaching and implantation forces for the modified stem were up to 40% higher (p = 0.024), achieving a 23% larger contact area between stem and bone (R2 = 0.694, p = 0.039) resulting in a four times lower subsidence during loading (p = 0.028). The slight design modifications showed the desired effect in this in-vitro study resulting in a higher primary stability suggesting a reduced risk of loosening. The higher forces required during the preparation of the cavity with the new broaches and during implantation of the stem could bare an increased risk for intraoperative periprosthetic fractures, which did not occur in this study.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Periprosthetic Fractures , Humans , Hip Prosthesis/adverse effects , Periprosthetic Fractures/epidemiology , Prosthesis Design , Arthroplasty, Replacement, Hip/adverse effects , Osseointegration , Femur/surgery , Reoperation/adverse effects , Retrospective Studies
9.
BMC Musculoskelet Disord ; 25(1): 283, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38609884

ABSTRACT

BACKGROUND: This study aimed to report the long-term survival of fixed-bearing medial unicompartmental knee arthroplasty (UKA) with a mean of 14-year follow-up, and to determine possible risk factors of failure. METHODS: We retrospectively evaluated 337 fixed-bearing medial UKAs implanted between 2003 and 2014. Demographic and radiographic parameters were measured, including pre-operative and post-operative anatomical femorotibial angle (aFTA), posterior tibial slope (PTS), and anatomical medial proximal tibial angle (aMPTA). Multivariate logistic regression analysis was applied to figure out risk factors. RESULTS: The mean follow-up time was 14.0 years. There were 32 failures categorized into implant loosening (n = 11), osteoarthritis progression (n = 7), insert wear (n = 7), infection (n = 4), and periprosthetic fracture (n = 3). Cumulative survival was 91.6% at 10 years and 90.0% at 15 years. No statistically significant parameters were found between the overall survival and failure groups. Age and hypertension were significant factors of implant loosening with odds ratio (OR) 0.909 (p = 0.02) and 0.179 (p = 0.04) respectively. In the insert wear group, post-operative aFTA and correction of PTS showed significance with OR 0.363 (p = 0.02) and 0.415 (p = 0.03) respectively. Post-operative aMPTA was a significant factor of periprosthetic fracture with OR 0.680 (p < 0.05). CONCLUSIONS: The fixed-bearing medial UKA provides successful long-term survivorship. Tibial component loosening is the major cause of failure. Older age and hypertension were factors with decreased risk of implant loosening.


Subject(s)
Arthroplasty, Replacement, Knee , Hypertension , Periprosthetic Fractures , Humans , Survivorship , Arthroplasty, Replacement, Knee/adverse effects , Follow-Up Studies , Retrospective Studies
10.
Acta Orthop Belg ; 90(1): 135-138, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38669663

ABSTRACT

This case report describes a single patient with recurrent implant fractures of his left total hip replacement. According to our knowledge this is the first patient in literature with recurrent implant fractures. This is a rare phenomenon as reason for revision. Risk factors for implant failure of total hip replacement include a lack of proximal support, a distally well fixed stem with proximal debonding, malalignment of the stem and raised BMI.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Prosthesis Failure , Recurrence , Reoperation , Humans , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/adverse effects , Male , Hip Prosthesis/adverse effects , Periprosthetic Fractures/surgery , Periprosthetic Fractures/etiology , Aged
11.
Bone Joint J ; 106-B(5): 442-449, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38688518

ABSTRACT

Aims: Periprosthetic proximal femoral fractures (PFFs) are a major complication after total hip arthroplasty (THA). Health status after PFF is not specifically investigated. The aim of this study is to evaluate the health status pattern over two years after sustaining a PFF. Methods: A cohort of patients with PFF after THA was derived from the Brabant Injury Outcomes Surveillance (BIOS) study. The BIOS study, a prospective, observational, multicentre follow-up cohort study, was conducted to obtain data by questionnaires pre-injury and at one week, and one, three, six, 12, and 24 months after trauma. Primary outcome measures were the EuroQol five-dimension three-level questionnaire (EQ-5D-3L), the Health Utility Index 2 (HUI2), and the Health Utility Index 3 (HUI3). Secondary outcome measures were general measurements such as duration of hospital stay and mortality. Results: A total of 70 patients with a PFF were included. EQ-5D utility scores were significantly lower on all timepoints except at six months' follow-up compared to pre-injury. EuroQol visual analogue scale (EQ-VAS) scores at one month's follow-up were significantly lower compared to pre-injury. The percentage of reported problems at two years was higher for all dimensions except anxiety/depression when compared to pre-injury. The mean EQ-5D utility score was 0.26 higher in males compared to females (95% confidence interval (CI) 0.01 to 0.42; p = 0.003). The mean EQ-VAS score for males was 8.9 points higher when compared to females over all timepoints (95% CI 1.2 to 16.7; p = 0.027). Mortality was 10% after two years' follow-up. Conclusion: PFF patients are a frail population with substantial functional impairment at baseline. Post-injury, they have a significant and clinically relevant lower health status two years after trauma when compared to pre-injury. Health status improves the most between one and three months after injury. Two years after PFF, more patients experience problems in mobility, self-care, usual activities, and pain/discomfort than pre-injury.


Subject(s)
Arthroplasty, Replacement, Hip , Health Status , Periprosthetic Fractures , Humans , Male , Female , Aged , Prospective Studies , Periprosthetic Fractures/etiology , Follow-Up Studies , Middle Aged , Quality of Life , Aged, 80 and over , Surveys and Questionnaires , Proximal Femoral Fractures
12.
Arch Orthop Trauma Surg ; 144(5): 2273-2281, 2024 May.
Article in English | MEDLINE | ID: mdl-38615291

ABSTRACT

INTRODUCTION: Following total knee arthroplasty (TKA), there is a significant decline in periprosthetic bone mineral density (BMD), potentially resulting in complications such as prosthetic loosening, periprosthetic fracture, and influencing the postoperative recovery. The objective of this study was to summarize the factors influencing periprosthetic BMD in TKA from existing studies. METHODS: A comprehensive systematic search was performed in 4 databases: Pubmed, Embase, Web of Science, and Cochrane Library. The last search was carried out on October 12, 2023. We used the keywords ''total knee arthroplasty'', ''bone mineral density'' and each of them combined with ''tibia'' and ''femur'' to identify all relevant articles reporting about potential impact factors influencing the periprosthetic BMD in patients after TKA. RESULTS: Out of 1391 articles, 22 published from 2001 to 2023 were included in this systematic review. Following eligibility screening, six significant categories affecting periprosthetic BMD were recognized: prosthesis type, design of stem, coating, body weight, cement, and peg distance. CONCLUSION: Mobile-bearing prostheses, modular polyethylene design, short stems, cruciform stems, avoidance of bone cement, higher body mass index, titanium nitride coating, and a smaller medial peg distance could potentially benefit periprosthetic BMD. Comprehensive consideration of diverse factors influencing periprosthetic BMD before surgery and collaboration with post-operative drug therapy are essential. TRIAL REGISTRY: The PROSPERO registration number is CRD42023472030.


Subject(s)
Arthroplasty, Replacement, Knee , Bone Density , Knee Prosthesis , Humans , Arthroplasty, Replacement, Knee/methods , Prosthesis Design , Periprosthetic Fractures/etiology , Prosthesis Failure
14.
Eur J Orthop Surg Traumatol ; 34(4): 2155-2162, 2024 May.
Article in English | MEDLINE | ID: mdl-38565783

ABSTRACT

INTRODUCTION: Increasing interest in the use of anatomical stems has developed as the prevalence of periprosthetic fractures (PPFs) continues to increase. The primary aim of this study was to determine the long-term survivorship and PPF rate of an anatomical femoral stem in a single UK centre. PATIENTS AND METHODS: Between 2000 and 2002, 94 consecutive THAs were performed using the 170 mm Lubinus SP II anatomical femoral stem in our institution. Patient demographics, operative details and clinical outcomes were collected prospectively in an arthroplasty database. Patient records and national radiographic archives were reviewed finally at a mean of 21.5 years (SD 0.7) following surgery to identify occurrence of subsequent revision surgery, dislocation or periprosthetic fracture. RESULTS: Mean patient age at surgery was 65.8 years (SD 12.5, 34-88 years). There were 48 women (51%). Osteoarthritis was the operative indication in 88 patients (94%). Analysis of all-cause THA failure demonstrated a survivorship of 98.5% (95% confidence interval [CI], 98.0-99.3%) at 10 years and 96.7% (94.5-98.9%) at 21 years. The 20-year stem survival for aseptic loosening was 100% with no cases of significant lysis found (lucent line > 2 mm) and no stems required revision. Patient demographics did not appear to influence risk of revision (p > 0.05). There were 2 revisions in total (2 for acetabular loosening with original stems retained). There were no PPFs identified at mean 21.5 year follow-up and 5 dislocations (5%). CONCLUSIONS: The Lubinus SP II 170 mm stem demonstrated excellent survivorship and negligible PPF rates over 20 years following primary THA.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Periprosthetic Fractures , Prosthesis Failure , Reoperation , Humans , Aged , Female , Male , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis/adverse effects , Periprosthetic Fractures/etiology , Periprosthetic Fractures/surgery , Reoperation/statistics & numerical data , Adult , Follow-Up Studies , United Kingdom , Prosthesis Design , Femur/surgery , Femur/diagnostic imaging , Osteoarthritis, Hip/surgery
15.
Orthop Traumatol Surg Res ; 110(4): 103878, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38582221

ABSTRACT

INTRODUCTION: The use of cemented stems in elderly patients is associated with the risk of intraoperative embolic complications. Uncemented stems eliminate this risk, but their use is controversial because of the risk of mechanical complications, with estimated subsidence between 3.6 and 30% and periprosthetic fractures between 2.1 and 11% at 6 weeks. A retrospective multicenter comparative study was conducted using a propensity score analysis to evaluate mechanical performances of uncemented stems in femoral neck fractures in elderly patients to (1) compare the risk of mechanical complications and (2) assess the use of metaphyseal-anchored stems for this indication. HYPOTHESIS: There is no difference in the risk of mechanical complications, intraoperatively or postoperatively, between these stems. MATERIALS AND METHODS: We conducted a multicenter retrospective comparative study including 358 uncemented and 313 cemented stems. The mean age was 84.5 years [83.9-85.1]. The inclusion criteria were patients 70 years and older and a follow-up of at least 6 weeks. The primary endpoint was a composite endpoint comprised of stem subsidence≥2mm or periprosthetic fracture (up to 3 months postoperatively). The secondary endpoints were infection, stem subsidence≥2mm, and operative time. These endpoints were analyzed using a propensity score to control confounding factors. A secondary analysis used the same endpoints to compare metaphyseal-anchored (short stems) versus Corail-like stems. RESULTS: After adjusting for the propensity score, we found 11.17% mechanical complications in the uncemented group (n=40, 5.59% subsidence, and 5.59% fractures) versus 13.42% for the cemented group (n=42, 7.99% subsidence, and 5.43% fractures). There was no statistically significant difference between the 2 values (Odds Ratio [OR]=0.64 [95% Confidence Interval [CI]: 0.14-2.85] [p=0.7]). The mortality rate due to cement embolism was 1%. There was no difference in the rate of subsidence (OR=0.55 [95% CI: 0.02-12.5] [p=0.7]), periprosthetic fracture (OR=0.65 [95% CI: 0.13-3.12] [p=0.7]) or infection (OR=0.71 [95% CI: 0.32-1.55] [p=0.4]). However, the operative times were longer in the cemented group (p=0.03 for hemiarthroplasties [mean additional time 16minutes] and p=0.02 for total hip arthroplasties [mean additional time 22minutes]). No difference was observed between the metaphyseal-anchored (short stems) and Corail-like stems regarding operative time, rate of infection, and rate of stem subsidence or periprosthetic fractures. DISCUSSION: This is one of the first studies to highlight cemented stem subsidence when used for femoral neck fractures in elderly patients. Using uncemented stems in this indication is still warranted, especially since they do not bring about more mechanical complications in the first few months. Metaphyseal-anchored short stems seem to give the same results as "standard" stems. However, these findings need to be assessed in the longer term. LEVEL OF EVIDENCE: III; retrospective comparative study.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Neck Fractures , Hip Prosthesis , Prosthesis Design , Humans , Retrospective Studies , Male , Female , Aged, 80 and over , Femoral Neck Fractures/surgery , Arthroplasty, Replacement, Hip/methods , Aged , Propensity Score , Bone Cements , Cementation , Periprosthetic Fractures/surgery , Postoperative Complications/epidemiology , Treatment Outcome , Follow-Up Studies
16.
Int Orthop ; 48(5): 1171-1178, 2024 May.
Article in English | MEDLINE | ID: mdl-38443715

ABSTRACT

PURPOSE: After cemented total hip arthroplasty, the risk of periprosthetic fracture (PPF) of taper-slip stems is higher than that of composite-beam stems. We aimed to assess the conditions resulting in PPFs of taper-slip stems using a falling weight. METHODS: Taper-slip stems were fixed to five types of simulated bone models using bone cement, and the fractures were evaluated by dropping stainless-steel weights from a predetermined height onto the heads. The periprosthetic fracture height in 50% of the bone models (PPFH50) was calculated using the staircase method. RESULTS: For the fixation with 0° of flexion, the values for PPFH50 were 61 ± 11, 60 ± 13, above 110, 108 ± 49, and 78 ± 12 cm for the cobalt-chromium-molybdenum alloy, stainless steel alloy (SUS), titanium alloy (Ti), smooth surface, and thick cement mantle models, respectively; for the fixation with 10° of flexion (considering flexure), the PPFH50 values were 77 ± 5, 85 ± 9, 90 ± 2, 89 ± 5, and 81 ± 11 cm, respectively. The fracture rates of the polished-surface stems were 78.6 and 35.7% at the proximal and distal sites, respectively (p < 0.05); the fracture rates of the smooth-surface stems were 14.2 and 100%, respectively (p < 0.05). CONCLUSION: The impact tests demonstrated that the conditions that were less likely to cause PPFs were use of Ti, a smooth surface, a thick cement mantle, and probably, use of SUS.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Hip Prosthesis , Periprosthetic Fractures , Humans , Periprosthetic Fractures/epidemiology , Periprosthetic Fractures/etiology , Periprosthetic Fractures/surgery , Hip Prosthesis/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Reoperation/adverse effects , Bone Cements , Prosthesis Design , Alloys , Femoral Fractures/surgery
17.
Orthopadie (Heidelb) ; 53(4): 275-283, 2024 Apr.
Article in German | MEDLINE | ID: mdl-38528206

ABSTRACT

Complications in the early postoperative period following the implantation of a unicondylar knee arthroplasty (UKA) are both rare and rarely described in the literature. Often, only small case series or individual case reports are available. In this article, the most common complications of periprosthetic infection, periprosthetic tibial fracture, inlay dislocation and intra-articular cement residue in (loose bone cement body) are described and recommendations for conservative and surgical treatment are presented, including case examples. Ideally, surgical errors or an infection should be recognized at an early stage and revised as soon as possible.


Subject(s)
Arthroplasty, Replacement, Knee , Periprosthetic Fractures , Tibial Fractures , Humans , Arthroplasty, Replacement, Knee/adverse effects , Tibia/surgery , Tibial Fractures/surgery , Periprosthetic Fractures/surgery
18.
Bone Joint J ; 106-B(4): 344-351, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38555949

ABSTRACT

Aims: Revision total hip arthroplasty in patients with Vancouver type B3 fractures with Paprosky type IIIA, IIIB, and IV femoral defects are difficult to treat. One option for Paprovsky type IIIB and IV defects involves modular cementless, tapered, revision femoral components in conjunction with distal interlocking screws. The aim of this study was to analyze the rate of reoperations and complications and union of the fracture, subsidence of the stem, mortality, and the clinical outcomes in these patients. Methods: A total of 46 femoral components in patients with Vancouver B3 fractures (23 with Paprosky type IIIA, 19 with type IIIB, and four with type IV defects) in 46 patients were revised with a transfemoral approach using a modular, tapered, cementless revision Revitan curved femoral component with distal cone-in-cone fixation and prospectively followed for a mean of 48.8 months (SD 23.9; 24 to 112). The mean age of the patients was 80.4 years (66 to 100). Additional distal interlocking was also used in 23 fractures in which distal cone-in-cone fixation in the isthmus was < 3 cm. Results: One patient (2.2%) died during the first postoperative year. After six months, 43 patients (93.5%) had osseous, and three had fibrous consolidation of the fracture and the bony flap, 42 (91.3%) had bony ingrowth and four had stable fibrous fixation of the stem. No patient had radiolucency around the interlocking screws and no screw broke. One patient had non-progressive subsidence and two had a dislocation. The mean Harris Hip Score increased from of 57.8 points (SD 7.9) three months postoperatively to 76.1 points (SD 10.7) 24 months postoperatively. Conclusion: The 2° tapered, fluted revision femoral component with distal cone-in-cone-fixation, combined with additional distal interlocking in patients with bony deficiency at the isthmus, led to reproducibly good results in patients with a Vancouver B3 fracture and Paprosky type IIIA, IIIB, and IV defects with regard to union of the fracture, subsidence or loosening of the stem, and clinical outcomes.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Hip Prosthesis , Periprosthetic Fractures , Humans , Aged, 80 and over , Arthroplasty, Replacement, Hip/methods , Periprosthetic Fractures/surgery , Periprosthetic Fractures/etiology , Hip Prosthesis/adverse effects , Treatment Outcome , Prosthesis Design , Reoperation/methods , Femoral Fractures/surgery , Retrospective Studies
19.
J Int Med Res ; 52(3): 3000605241240946, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38534086

ABSTRACT

BACKGROUND: To compare the biomechanical stability of a novel, C-shaped nickel-titanium shape memory alloy (SMA) implant (C-clip) with traditional cerclage wiring in the fixation of a Vancouver B1 (VB1) periprosthetic femoral fracture (PFF). METHODS: In total, 18 synthetic femoral fracture models were constructed to obtain unstable VB1 fracture with an oblique fracture line 8 cm below the lesser trochanter. For each model, the distal portion was repaired using a 10-hole locking plate and four distal bi-cortical screws. The proximal portion was repaired using either three, threaded cerclage wirings or three, novel C-shaped implants. Specimens underwent biomechanical testing using axial compression, torsional and four-point bending tests. Each test was performed on three specimens. RESULTS: The C-clip was statistically significantly stronger (i.e., stiffer) than cerclage wiring in the three biomechanical tests. For axial compression, medians (ranges) were 39 (39-41) and 35 (35-35) N/mm, for the C-clip and cerclage wiring, respectively. For torsion, medians (ranges) were, 0.44 (0.44-0.45) and 0.30 (0.30-0.33) N/mm for the C-clip and cerclage wiring, respectively. For the four-point bending test, medians (ranges) were 39 (39-41) and 28 (28-31) N/mm; for the C-clip and cerclage wiring, respectively. CONCLUSION: Results from this small study show that the novel, C-shaped SMA appears to be biomechanically superior to traditional cerclage wiring in terms of stiffness, axial compression, torsion and four-point bending, and may be a valuable alternative in the repair of VB1 PFF. Further research is necessary to support these results.


Subject(s)
Femoral Fractures , Periprosthetic Fractures , Humans , Shape Memory Alloys , Femoral Fractures/surgery , Femur/surgery , Periprosthetic Fractures/surgery , Fracture Fixation, Internal/methods , Bone Plates , Biomechanical Phenomena
20.
J Pediatr Orthop ; 44(5): e452-e456, 2024.
Article in English | MEDLINE | ID: mdl-38506352

ABSTRACT

OBJECTIVE: Of children, 30% to 35% with cerebral palsy (CP) develop hip subluxation or dislocation and often require reconstructive hip surgery, including varus derotation osteotomy (VDRO). A recent literature review identified postoperative fractures as the most common complication (9.4%) of VDROs. This study aimed to assess risk factors for periprosthetic fracture after VDRO in children with CP. METHODS: A total of 347 patients (644 hips, 526 bilateral hips) with CP and hip subluxation or dislocation (129 females; mean age at index VDRO: 8.6 y, SD 3.4, range: 1.5 to 17.7; 2 Gross Motor Function Classification System (GMFCS) I, 35 GMFCS II, 39 GMFCS III, 119 GMFCS IV, 133 GMFCS V, 21 unavailable) were included in this retrospective, single-group intervention (VDRO) study at a tertiary referral center. Imaging and clinical documentation for patients age 18 years or younger at index surgery, treated with VDRO were reviewed to determine demographic data, GMFCS level, surgeon, type of hardware implanted, use of anticonvulsants and steroids, type of postoperative immobilization, presence of periprosthetic fractures, fracture location and mechanism, and time from surgery to fracture. Potential determinants of periprosthetic fractures were assessed using mixed effects logistic regression. RESULTS: Of 644 hips, 14 (2.2%, 95% CI: 1.3%, 3.6%) sustained a periprosthetic fracture, at a median of 2.1 years postoperatively (interquartile range: 4.6 y, range: 1.2 mo to 7.8 y). Patients with a fracture had a median age at index surgery of 7.3 years (interquartile range: 4.3, range: 2.8 to 17.8; 1 GMFCS II, 6 GMFCS IV, 7 GMFCS V). Periprosthetic fractures were not significantly related to age at index surgery ( P = 0.18), sex ( P = 0.30), body mass index percentile ( P = 0.87), surgery side ( P = 0.16), anticonvulsant use ( P = 0.35), type of postoperative immobilization ( P = 0.40), GMFCS level ( P = 0.31), or blade plate size ( P = 0.17). Only surgeon volume significantly related to periprosthetic fracture (odds ratio = 5.03, 95% CI: 1.53, 16.56, P = 0.008), with the highest-volume surgeon also using smaller blade plates ( P < 0.01). CONCLUSIONS: Periprosthetic fractures after VDRO surgery in children with CP are uncommon, and routine hardware removal appears unnecessary. The data suggest that the common dogma of putting in the largest blade plate possible to maximize fixation may increase the risk of periprosthetic fracture. Due to the overall low fracture rate, especially when contextualized relative to the risk of hardware removal, a reactive approach to hardware removal appears warranted. LEVEL OF EVIDENCE: Level III-retrospective study (targeting varus derotational osteotomies in children with cerebral palsy).


Subject(s)
Cerebral Palsy , Hip Dislocation , Joint Dislocations , Periprosthetic Fractures , Child , Female , Humans , Adolescent , Retrospective Studies , Periprosthetic Fractures/epidemiology , Periprosthetic Fractures/etiology , Periprosthetic Fractures/surgery , Cerebral Palsy/complications , Cerebral Palsy/epidemiology , Incidence , Hip Dislocation/epidemiology , Hip Dislocation/etiology , Hip Dislocation/surgery , Joint Dislocations/etiology , Osteotomy/adverse effects , Osteotomy/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...