Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 13.431
Filter
1.
Sci Rep ; 14(1): 12850, 2024 06 04.
Article in English | MEDLINE | ID: mdl-38834618

ABSTRACT

This study aimed to compare the IOP-lowering effectiveness and safety of standalone Preserflo MicroShunt and iStent 1st generation implantation combined with phacoemulsification in Caucasian patients with a 12-month follow-up period. This retrospective study analyzed the medical histories of patients undergoing antiglaucoma surgery at the Department of Ophthalmology, Medical University of Bialystok, between January 2019 and January 2022. The main outcome measures were success rates (complete: proportion of eyes with IOP < 18 mmHg (criterion A) and < 15 mmHg (criterion B) or 20% reduction in IOP without any glaucoma medication; qualified: proportion of eyes achieving IOPs < 18 mmHg and < 15 mmHg or 20% reduction in IOP from baseline with or without medications), mean reduction (%) in IOP, medication burden, number of complications and additional interventions. In both groups, a significant decrease in IOP and medication burden were observed at 6 and 12 months when compared with baseline. At 12 months, qualified surgical success in criterion A was recorded in 67.4% and 85.7% of patients in the Preserfo and iStent groups, respectively (p = 0.045). Complete surgical success in criterion B at 12 months accounted to 61.4% of patients from Prserflo group and 32.7% patients in iStent group (p = 0.04). Surgical failure at 12 months was documented in 30.2% and 6.3% of patients, respectively (p = 0.003). There was a significant difference between groups in %IOP reduction after 12 months. Greater reduction was observed in Preserflo group, MD = - 8.41 CI95 [- 15.88; - 0.95], p = 0.028, (- 33.49% ± 21.59 vs - 25.07% ± 14.15 in iStent group). Both procedures effectively reduced IOP and postoperative use of antiglaucoma medications in glaucoma patients.


Subject(s)
Glaucoma , Intraocular Pressure , Minimally Invasive Surgical Procedures , Humans , Male , Female , Retrospective Studies , Minimally Invasive Surgical Procedures/methods , Aged , Glaucoma/surgery , Middle Aged , Treatment Outcome , Phacoemulsification/methods , Phacoemulsification/adverse effects , Glaucoma Drainage Implants , Aged, 80 and over
2.
Zhonghua Yan Ke Za Zhi ; 60(6): 511-517, 2024 Jun 11.
Article in Chinese | MEDLINE | ID: mdl-38825950

ABSTRACT

Objective: To assess the impact of femtosecond laser-assisted phacoemulsification on corneal endothelial characteristics and prognosis among patients with type 2 diabetes and age-related cataracts, considering varying nuclear hardness. Methods: This non-randomized controlled trial involved 161 patients (161 eyes) with type 2 diabetes undergoing cataract extraction at Weifang Eye Hospital between March 2020 and December 2022. The cohort comprised 73 males and 88 females, with an average age of (65.9±5.23) years. Based on patient preference, 101 individuals underwent conventional phacoemulsification (group A), while 60 chose femtosecond laser-assisted phacoemulsification (group B). Patients were further stratified based on Emery-Little grade of lens nuclei into A1/B1 (grade Ⅰ and Ⅱ), A2/B2 (grade Ⅲ), and A3/B3 (grade Ⅳ) subgroups. The study compared effective phacoemulsification time (EPT), cumulative energy release of phacoemulsification (CDE), central corneal thickness (CCT), endothelial cell density (ECD), coefficient of variation (CV), and hexagon cell ratio (HEX) before and after surgery at 1 day, 1 week, 1 month, and 3 months. Results: The intraoperative EPT of patients in groups A and B were (6.52±4.93) and (5.63±4.31)s, respectively, and the CDE were 11.57%±5.21% and 10.68%±6.02%, respectively. The differences between them were not statistically significant (all P>0.05).There were no significant differences in EPT and CDE between groups A1 and B1 (all P>0.05), and there were statistically significant differences between groups A2 and B2, A3 and B3 (all P<0.05).The postoperative CCT was increased in both groups.There were no statistically significant differences in CCT between A1 and B1 groups at different time after surgery (all P>0.05), and there were statistically significant differences in CCT between A2 and B2, A3 and B3 groups at 1 day and 1 week after surgery (all P<0.05), and group B was significantly lower than group A.There was no significant difference between 1 month and 3 months after surgery (P>0.05).ECD was reduced in both groups.There was no statistically significant difference in ECD at different time of operation between A1 and B1 groups (all P>0.05), while there was statistically significant difference in ECD at 1 day, 1 week, 1 month and 3 months after operation in A2 and B2, A3 and B3 groups (all P<0.05). Group B was significantly better than group A. There was no significant difference in coefficient of variation and HEX between the two groups at different time after surgery (P>0.05). Conclusion: Femtosecond laser-assisted phacoemulsification demonstrates benefits in preserving corneal endothelial cells, reducing early postoperative corneal edema, and minimizing corneal injury in type 2 diabetes patients with cataracts of high nuclear hardness.


Subject(s)
Cataract , Diabetes Mellitus, Type 2 , Endothelium, Corneal , Phacoemulsification , Humans , Male , Female , Aged , Phacoemulsification/methods , Diabetes Mellitus, Type 2/complications , Prognosis , Laser Therapy/methods , Lens Implantation, Intraocular/methods , Cataract Extraction/methods , Middle Aged
3.
Medicine (Baltimore) ; 103(23): e37584, 2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38847669

ABSTRACT

PURPOSE: To evaluate the clinical effects between dexamethasone and triamcinolone acetonide (TA) after phacoemulsification and intraocular lens implantation among cataract patients. METHODS: Pubmed, Embase, and the Cochrane Library were searched for studies published up to August 2020. The primary outcome was intraocular pressure. The secondary outcomes were the logarithm of the minimum angle of resolution (logMAR), anterior chamber cell, and anterior chamber flare. The pooled effect sizes were expressed as weighted mean differences (WMDs) or standardized mean differences (SMDs) of 95% confidence intervals (95% CIs). Cochrane Collaboration risk of bias tool and Newcastle-Ottawa scale criteria were used for the quality assessment of included studies. RESULTS: Seven relevant studies met the inclusion criteria. For the primary outcome, there was no significant difference between TA injection and dexamethasone in comparing intraocular pressure (IOP) (SMD = 0.22, 95% confidence interval [CI] [-0.29, 0.73], P = .408; I²â€…= 86.9%) in the first day after treatment and last day of assessment. For the secondary outcomes, the logMAR (WMD = 0.01, 95% CI [-0.06, 0.08]) and the anterior chamber flare (SMD = 0.08, 95% CI [-0.01, 0.18], P = .087; I²â€…= 0%) showed no differences. However, the amount of anterior chamber cells (SMD = -0.21, 95% CI [-0.42, -0.01], P = .044; I²â€…= 0%) in the TA injection on the first day postoperative was higher than for dexamethasone. After treatment, there was no difference between the 2 groups. CONCLUSIONS: This study supports that there were no differences in IOP, logMAR, and anterior chamber flare between TA injection and dexamethasone among cataract patients. TA injection treatment on the first day showed higher amounts of anterior chamber cells than with dexamethasone.


Subject(s)
Dexamethasone , Glucocorticoids , Triamcinolone Acetonide , Humans , Dexamethasone/administration & dosage , Dexamethasone/therapeutic use , Triamcinolone Acetonide/administration & dosage , Triamcinolone Acetonide/therapeutic use , Glucocorticoids/administration & dosage , Glucocorticoids/therapeutic use , Phacoemulsification/methods , Intraocular Pressure/drug effects , Lens Implantation, Intraocular , Treatment Outcome , Cataract Extraction/methods
4.
J Refract Surg ; 40(6): e354-e361, 2024 May.
Article in English | MEDLINE | ID: mdl-38848053

ABSTRACT

PURPOSE: To assess the predictive accuracy of new-generation online intraocular lens (IOL) power formulas in eyes with previous myopic laser refractive surgery (LRS) and to evaluate the influence of corneal asphericity on the predictive accuracy. METHODS: The authors retrospectively evaluated 52 patients (78 eyes) with a history of laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) who subsequently underwent cataract surgery. Refractive prediction errors were calculated for 12 no-history new online formulas: 8 formulas with post-LRS versions (Barrett True-K, EVO 2.0, Hoffer QST, and Pearl DGS) using keratometry and posterior/total keratometry measured by IOLMaster 700 and 4 formulas without post-LRS versions (Cooke K6 and Kane) using keratometry and total keratometry. The refractive prediction error, mean absolute error (MAE), and percentages of eyes with prediction errors of ±0.25, ±0.50, ±0.75, ±1.00, and ±1.50 diopters (D) were compared. RESULTS: The MAEs of the 12 formulas were significantly different (F = 83.66, P < .001). The MAEs ranged from 0.62 to 0.94 D and from 1.07 to 1.84 D in the formulas with and without post-LRS versions, respectively. The EVO formula produced the lowest MAE (0.60) and MedAE (0.47), followed by the Barrett True-K (0.69 and 0.50, respectively). Each percentage of eyes with refractive prediction error was also significantly different among the 12 formulas (P < .001). CONCLUSIONS: The EVO and Barrett True-K formulas demonstrate comparable performance to the other existing formulas in eyes with a history of myopic LASIK/PRK. Surgeons should use these formulas with post-LRS versions and input keratometric values whenever possible. [J Refract Surg. 2024;40(6):e354-e361.].


Subject(s)
Keratomileusis, Laser In Situ , Lens Implantation, Intraocular , Lenses, Intraocular , Myopia , Optics and Photonics , Photorefractive Keratectomy , Refraction, Ocular , Visual Acuity , Humans , Retrospective Studies , Myopia/surgery , Myopia/physiopathology , Female , Male , Refraction, Ocular/physiology , Middle Aged , Photorefractive Keratectomy/methods , Keratomileusis, Laser In Situ/methods , Adult , Visual Acuity/physiology , Lasers, Excimer/therapeutic use , Cornea/surgery , Cornea/physiopathology , Reproducibility of Results , Biometry/methods , Phacoemulsification , Aged
5.
J Refract Surg ; 40(6): e407-e419, 2024 May.
Article in English | MEDLINE | ID: mdl-38848051

ABSTRACT

PURPOSE: To assess clinical outcomes after cataract surgery with bilateral implantation of a new bi-aspheric diffractive intraocular lens (IOL). METHODS: Thirty patients underwent bilateral implantation of the Asqelio Trifocal Toric IOL (AST Products, Inc) and were evaluated 3 months postoperatively. Main outcomes included refractive error, photopic monocular and binocular uncorrected and corrected distance (UDVA, CDVA), intermediate (UIVA, CDIVA) at 60 cm, and near (UNVA, CDNVA) at 40 cm visual acuities. Mesopic monocular and binocular CDNVA were also measured. Defocus curves, binocular contrast sensitivity under photopic and mesopic conditions with and without glare and rotational stability were determined. Patients completed Catquest-9SF and visual symptoms questionnaires. RESULTS: Average values of binocular photopic CDVA, CDIVA, and CDNVA, and mesopic CDNVA were -0.04 ± 0.06, 0.02 ± 0.08, 0.02 ± 0.07, and 0.22 ± 0.11 logMAR, respectively. All patients achieved cumulative CDVA ⩾ 20/25, and CDIVA and CDNVA of 20/32 or better. Binocular depth of focus was approximately 3.25 diopters (D). Mean postoperative spherical equivalent was -0.08 ± 0.26 D, with 95% of eyes within ±0.50 D. Mean postoperative refractive cylinder was -0.22 ± 0.27 D, with 91.67% of eyes within 0.50 D or less, respectively. IOL rotation averaged 0.25 ± 0.65 degrees, all eyes having rotation of less than 5 degrees. Contrast sensitivity was within or above normal levels under photopic and mesopic conditions, with or without glare, except for 12 cpd under mesopic conditions with glare. Questionnaire responses indicated 96.67% of patients were satisfied or very satisfied with postoperative vision, and 80.00% to 96.67% reported no difficulty in different daily activities. CONCLUSIONS: The Asqelio Trifocal Toric IOL demonstrated favorable outcomes, providing excellent visual performance at all distances, precise refractive results, and remarkable rotational stability. Patients reported high satisfaction levels and minimal difficulty in daily activities. [J Refract Surg. 2024;40(6):e407-e419.].


Subject(s)
Contrast Sensitivity , Lens Implantation, Intraocular , Multifocal Intraocular Lenses , Patient Satisfaction , Phacoemulsification , Prosthesis Design , Pseudophakia , Refraction, Ocular , Vision, Binocular , Visual Acuity , Humans , Visual Acuity/physiology , Vision, Binocular/physiology , Male , Female , Aged , Refraction, Ocular/physiology , Pseudophakia/physiopathology , Middle Aged , Contrast Sensitivity/physiology , Surveys and Questionnaires , Prospective Studies , Aged, 80 and over , Lenses, Intraocular , Treatment Outcome
6.
J Refract Surg ; 40(6): e398-e406, 2024 May.
Article in English | MEDLINE | ID: mdl-38848057

ABSTRACT

PURPOSE: To assess the visual and refractive outcomes of patients implanted with a toric extended depth-of-focus (EDOF) intraocular lens (IOL) following cataract surgery. METHODS: A total of 44 eyes implanted with the EDOF LuxSmart toric IOL were evaluated 4 to 6 months postoperatively. The main outcomes measurements evaluated were refractive error, rotational stability, distance, intermediate, and near visual acuities, defocus curve, photopic and mesopic contrast sensitivity, wavefront aberrations, and modulation transfer function, and the Catquest-9SF-questionnaire. RESULTS: The mean postoperative spherical equivalent and cylinder were -0.02 ± 0.26 and -0.17 ± 0.29 diopters (D), respectively. A total of 90.45% and 100% of the eyes had a postoperative spherical equivalent within ±0.50 and ±1.00 D, respectively (this being 93.18% and 100% for the refractive cylinder). The mean rotational stability was 0.61 ± 1.61 degrees. The mean binocular corrected distance visual acuity (CDVA), corrected distance intermediate visual acuity (CDIVA), and corrected distance near visual acuity (CDNVA) were -0.02 ± 0.06, 0.07 ± 0.08, and 0.26 ± 0.09 logMAR, respectively. The CDVA was 20/25 or better in 95.45% of patients, CDIVA was 20/25 or better in 72.73%, and CDNVA was 20/40 or better in 72.73%. The defocus curve showed good visual acuity at distance and intermediate vergences. The contrast sensitivity and optical quality outcomes were good with mean higher order, spherical, and coma aberration values of 0.161 ± 0.155, -0.019 ± 0.048, and 0.080 ± 0.065 µm, respectively. A total of 90.9% of patients were either fairly satisfied or very satisfied with their vision after the surgery, and 77.7% of patients reported no difficulties when reading text in newspapers. CONCLUSIONS: Implantation of the toric pure refractive EDOF technology IOL provides good refractive, optical, and visual quality at different distances, with high levels of patient satisfaction being reported. [J Refract Surg. 2024;40(6):e398-e406.].


Subject(s)
Contrast Sensitivity , Corneal Wavefront Aberration , Depth Perception , Lens Implantation, Intraocular , Lenses, Intraocular , Phacoemulsification , Prosthesis Design , Pseudophakia , Refraction, Ocular , Vision, Binocular , Visual Acuity , Humans , Visual Acuity/physiology , Female , Male , Middle Aged , Aged , Contrast Sensitivity/physiology , Pseudophakia/physiopathology , Refraction, Ocular/physiology , Corneal Wavefront Aberration/physiopathology , Depth Perception/physiology , Vision, Binocular/physiology , Surveys and Questionnaires , Prospective Studies , Patient Satisfaction , Aged, 80 and over , Treatment Outcome
7.
Int Ophthalmol ; 44(1): 211, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38696090

ABSTRACT

PURPOSE: To evaluate the effects of sodium hyaluronate drops on dry eye parameters and corneal epithelial thickness following cataract surgery. METHODS: The study included 84 patients who underwent uncomplicated phacoemulsification. In Group A, 0.15% sodium hyaluronate drops were added to the postoperative antibiotic/anti-inflammatory treatment. In Group B, only antibiotic/anti-inflammatory treatment was applied. Preoperatively and at 1 week and 1 month postoperatively, all the patients were evaluated in respect of tear break-up time (TBUT), the Schirmer test under anesthesia, the corneal fluorescein staining (CFS) score, mean central corneal thickness (CCT) and mean central corneal epithelial thickness (CCET), and the two groups were compared. RESULTS: A statistically significant difference was determined between the two groups at postoperative 1 month in respect of TBUT, Schirmer test, CFS score, and CCET (p < 0.01). In Group A, a statistically significant increase was determined in the TBUT and Schirmer values at 1 month postoperatively (p < 0.01, p = 0.01, respectively) and in Group B, these values were decreased compared to preoperatively (p < 0.01). The CCET was determined to be significantly thinner in Group B 1 month postoperatively (p < 0.01). A significant increase in CCT was observed in both groups at postoperative 1 week (p < 0.01) and preoperative values were reached at 1 month postoperatively. CONCLUSION: In the patient group using sodium hyaluronate, significant differences were determined in all dry eye parameters and CCET. The use of hyaluronate sodium drops after cataract surgery was seen to improve dry eye parameters and contribute to a healthy ocular surface by ensuring continuity of the corneal epithelium.


Subject(s)
Dry Eye Syndromes , Epithelium, Corneal , Hyaluronic Acid , Ophthalmic Solutions , Phacoemulsification , Humans , Hyaluronic Acid/administration & dosage , Dry Eye Syndromes/drug therapy , Dry Eye Syndromes/diagnosis , Female , Male , Aged , Epithelium, Corneal/drug effects , Epithelium, Corneal/pathology , Middle Aged , Ophthalmic Solutions/administration & dosage , Phacoemulsification/methods , Viscosupplements/administration & dosage , Prospective Studies , Tears/metabolism , Postoperative Complications/prevention & control , Cataract Extraction/methods
8.
Ulster Med J ; 93(1): 12-17, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38707980

ABSTRACT

Background: The practice of immediate sequential bilateral cataract surgery (ISBCS) was more widely adopted in the UK during the COVID-19 pandemic, in response to limited surgical capacity and the risk of nosocomial infection. This study reports on a single site experience of ISBCS in Northern Ireland. Methods: Data was collected prospectively between 17th November 2020 and 30th November 2021. The ISBCS surgical protocol, recommended by RCOphth and UKISCRS, was followed. Primary outcomes measures were: postoperative visual acuity (VA), refractive prediction accuracy, intraoperative and postoperative complications. Results: Of 41 patients scheduled, 39 patients completed ISBCS and two patients underwent unilateral surgery (n=80 eyes). Mean age at the time of surgery was 71.6 years (standard deviation (SD) ±11.8 years). Median preoperative VA was 0.8 logMAR (range: PL to 0.2 logMAR). Seventeen (20.9%) eyes were highly myopic and 9 (11.1%) eyes were highly hypermetropic. Median cumulative dissipated phacoemulsification energy was 15.7 sec (range: 1.8 sec to 83.4 sec). Median case time was 10.4 min (range: 4.3 min to 37.1 min).One eye (1.3%) developed iritis secondary to a retained tiny cortical fragment. Four eyes (5.0%, n=3 patients) developed cystoid macular oedema, with full resolution. On wide field imaging, an asymptomatic unilateral peripheral suprachoroidal haemorrhage was noted in two highly myopic patients (axial lengths of 27.01mm and 25.05mm respectively). The posterior pole was spared, and both resolved spontaneously without any visual impairment. Conclusions: In our initial experience, ISBCS was found to be a safe approach to cataract surgery. Our patient cohort included eyes with dense cataracts and high ametropia. Further studies are required to assess patient reported outcome measures and the possible economic benefits of ISBCS in our local population.


Subject(s)
COVID-19 , Cataract Extraction , Visual Acuity , Humans , COVID-19/epidemiology , Aged , Male , Female , Cataract Extraction/methods , Middle Aged , Northern Ireland/epidemiology , Prospective Studies , Postoperative Complications/epidemiology , Aged, 80 and over , SARS-CoV-2 , Phacoemulsification/methods , Phacoemulsification/adverse effects , Pandemics
9.
BMC Ophthalmol ; 24(1): 206, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38711059

ABSTRACT

PURPOSE: The main objective is to quantify the lens nuclear opacity using spectral-domain optical coherence tomography (SD-OCT) and to evaluate its association with Lens Opacities Classification System III (LOCS-III) system, lens thickness (LT), and surgical parameters. The secondary objective is to assess the diagnostic model performance for hard nuclear cataract. METHODS: This study included 70 eyes of 57 adults with cataract, with 49 (70%) and 21 (30%) in training and validation cohort, respectively. Correlations of the average nuclear density (AND) /maximum nuclear density (MND) with LOCS-III scores, LT, and surgical parameters were analyzed. Univariate and multivariate logistic regression analysis, receiver operating characteristic curves and calibration curves were performed for the diagnostic of hard nuclear cataract. RESULTS: The pre-operative uncorrected distance visual acuity (UDVA), intraocular pressure (IOP), mean axial length (AL), and LT were 1.20 ± 0.47 log MAR, 15.50 ± 2.87 mmHg, 27.34 ± 3.77 mm and 4.32 ± 0.45 mm, respectively. The average nuclear opalescence (NO) and nuclear colour (NC) scores were 3.61 ± 0.94 and 3.50 ± 0.91 (ranging from 1.00 to 6.90), respectively. The average AND and MND were 137.94 ± 17.01 and 230.01 ± 8.91, respectively. NC and NO scores both significantly correlated with the AND (rNC = 0.733, p = 0.000; rNO = 0.755, p = 0.000) and MND (rNC = 0.643, p = 0.000; rNO = 0.634, p = 0.000). In the training cohort, the area under the curve (AUC) of the model was 0.769 (P < 0.001, 95%CI 0.620-0.919), which had a good degree of differentiation (Fig. 2a). The calibration curve showed good agreement between predicted and actual probability. CONCLUSION: The nuclear density measurement on SD-OCT images can serve as an objective and reliable indicator for quantifying nuclear density.


Subject(s)
Cataract , Lens Nucleus, Crystalline , Tomography, Optical Coherence , Visual Acuity , Humans , Female , Male , Tomography, Optical Coherence/methods , Cataract/diagnosis , Aged , Middle Aged , Lens Nucleus, Crystalline/pathology , Lens Nucleus, Crystalline/diagnostic imaging , Visual Acuity/physiology , ROC Curve , Retrospective Studies , Phacoemulsification , Aged, 80 and over , Adult , Lens, Crystalline/diagnostic imaging , Lens, Crystalline/pathology
10.
J Refract Surg ; 40(5): e304-e312, 2024 May.
Article in English | MEDLINE | ID: mdl-38717085

ABSTRACT

PURPOSE: To compare intraoperative performance and early postoperative outcomes following phacoemulsification with two systems using active fluidics and one using gravity-based fluidics. METHODS: In this prospective randomized trial, 200 eyes were randomized to the traditional and Active Sentry groups (n = 80 eyes each) where the Centurion Vision System was used with traditional or Active Sentry (Alcon Laboratories, Inc) hand-pieces, respectively, or the Infinit group (n = 40 eyes) where the Infiniti Vision System (Alcon Laboratories, Inc) was used. Within the traditional and Active Sentry groups, there were two subgroups with low (30 mm Hg) or high (55 mm Hg) intraocular pressure (IOP) used. Outcome measures compared were: cumulative dissipated energy (CDE), percentage change in central corneal thickness (CCT) at 1 day, 1 week, and 1 month, anterior chamber cells at 1 day and 1 week, rate of rise and fall of IOP following occlusion break, corneal endothelial cell density (ECD), and macular thickness 6 months postoperatively. RESULTS: CDE was significantly lower in group II compared to the traditional group (2.96 ± 1.4 vs 4.14 ± 2.2, P = .001). With 30 mm Hg IOP, the Active Sentry group had significantly less percentage change in CCT at 1 week postoperatively compared to the traditional handpiece group (0.01% vs 0.02%, P = .008). Incidence of anterior chamber cells less than grade 2 on day 1 was significantly higher in the Active Sentry group (82.9% vs 52%, P = .03). Percentage change in ECD was significantly lower in the Active Sentry group (-0.957 vs -0.98%, P = .005). Significantly faster rise of IOP to baseline following occlusion break was seen in the Active Sentry group. CONCLUSIONS: The use of Active Sentry handpiece was associated with lower CDE, less postoperative increase in CCT, fewer anterior chamber cells, and faster rise of IOP following occlusion break. [J Refract Surg. 2024;40(5):e304-e312.].


Subject(s)
Intraocular Pressure , Lens Implantation, Intraocular , Phacoemulsification , Visual Acuity , Humans , Prospective Studies , Intraocular Pressure/physiology , Male , Female , Aged , Visual Acuity/physiology , Middle Aged , Endothelium, Corneal/pathology , Cell Count , Postoperative Period , Tomography, Optical Coherence , Hydrodynamics , Anterior Chamber , Intraoperative Period
11.
Vestn Oftalmol ; 140(2): 34-39, 2024.
Article in Russian | MEDLINE | ID: mdl-38742496

ABSTRACT

PURPOSE: This study evaluates the accuracy of modern intraocular lens (IOL) calculation formulas using axial length (AL) data obtained by ultrasound biometry (UBM) compared to the third-generation SRK/T calculator. MATERIAL AND METHODS: The study included 230 patients (267 eyes) with severe lens opacities that prevented optical biometry, who underwent phacoemulsification (PE) with IOL implantation. IOL power calculation according to the SRK/T formula was based on AL and anterior chamber depth obtained by UBM (Tomey Biometer Al-100) and keratometry on the Topcon KR 8800 autorefractometer. To adapt AL for new generation calculators - Barrett Universal II (BUII), Hill RBF ver. 3.0 (RBF), Kane and Ladas Super Formula (LSF) - the retinal thickness (0.20 mm) was added to the axial length determined by UBM, and then the optical power of the artificial lens was calculated. The mean error and its modulus value were used as criteria for the accuracy of IOL calculation. RESULTS: A significant difference (p=0.008) in the mean IOL calculation error was found between the formulas. Pairwise analysis revealed differences between SRK/T (-0.32±0.58 D) and other formulas - BUII (-0.16±0.52 D; p=0.014), RBF (-0.17±0.51 D; p=0.024), Kane (-0.17±0.52 D; p=0.029), but not with the LSF calculator (-0.19±0.53 D; p=0.071). No significant differences between the formulas were found in terms of mean error modulus (p=0.238). New generation calculators showed a more frequent success in hitting target refraction (within ±1.00 D in more than 95% of cases) than the SRK/T formula (86%). CONCLUSION: The proposed method of adding 0.20 mm to the AL determined by UBM allows using this parameter in modern IOL calculation formulas and improving the refractive results of PE, especially in eyes with non-standard anterior segment structure.


Subject(s)
Biometry , Lenses, Intraocular , Phacoemulsification , Refraction, Ocular , Humans , Biometry/methods , Male , Female , Aged , Middle Aged , Reproducibility of Results , Refraction, Ocular/physiology , Phacoemulsification/methods , Axial Length, Eye/diagnostic imaging , Lens Implantation, Intraocular/methods , Cataract/physiopathology , Cataract/diagnosis , Optics and Photonics/methods , Microscopy, Acoustic/methods
12.
Vestn Oftalmol ; 140(2): 24-32, 2024.
Article in Russian | MEDLINE | ID: mdl-38742495

ABSTRACT

PURPOSE: This study was conducted to develop a new optimized phacoemulsification technique for Morgagnian cataract taking into account the anatomical and topographic parameters of the lens nucleus. MATERIAL AND METHODS: A working classification of Morgagnian cataract was developed based on the size of the nucleus: if the edge of the nucleus is visualized at the upper edge of the pupil or between the upper edge and the middle of the pupil, it was classified as an initial stage of Morgagnian cataract with a large nucleus; if the upper edge of the nucleus is visualized in the middle of the pupil and below, it was classified as an advanced stage of Morgagnian cataract with a small nucleus. The first group included six patients who underwent surgery using the scaffold technique with removal of the whole small nucleus into the anterior chamber. The second group included 11 patients who underwent surgery using the scaffold technique with removal of the last fragment of the nucleus into the anterior chamber. RESULTS: The use of the scaffold technique with removal of the nucleus into the anterior chamber helped reduce the number of intraoperative complications to 16.7% in the first group, compared to 27.3% in the second group, and the percentage of endothelial cell loss to 10.1% in the first group, compared to 10.7% in the second group. CONCLUSIONS: The anatomical and topographic features of the lens and the anterior segment of the eye in Morgagnian cataract with a small nucleus allow for preliminary implantation of an intraocular lens into the capsular bag to protect the posterior capsule during phacoemulsification of the nucleus with minimal mechanical, hydrodynamic and acoustic damage to the surrounding structures of the eye.


Subject(s)
Cataract , Phacoemulsification , Humans , Phacoemulsification/methods , Cataract/complications , Male , Female , Middle Aged , Treatment Outcome , Aged , Visual Acuity , Lens Nucleus, Crystalline/surgery , Lens Nucleus, Crystalline/pathology , Intraoperative Complications/prevention & control , Intraoperative Complications/etiology
13.
BMC Ophthalmol ; 24(1): 210, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38741065

ABSTRACT

BACKGROUND: Parry-Romberg syndrome (PRS) is a rare progressive degenerative disorder of unknown etiology. Here we report a rare case of PRS combined with lens subluxation in Eye and ENT hospital of Fudan University, Shanghai. To our knowledge, it is the first reported case of PRS combined with lens subluxation that has been managed surgically with phacoemulsification and CTR placement and IOL implantation in Shanghai. CASE PRESENTATION: A 60-year-old woman was referred for "right visual blur for 2 years" and had persistent right facial paralysis of unknown etiology since the age 12. She had right facial muscle atrophy and paralysis. Eye examination also showed the right eyelid pseudoptosis, enophthalmos, age-related cataract combined with lens subluxation existed in the right eye. The patient was diagnosed as age-related cataract and lens subluxation in the right eye and progressive hemifacial atrophy (Parry-Romberg syndrome). We conducted a combined phacoemulsification, IOL and CTR implantation and pupilloplasty surgery for the patient under general anesthesia and the postoperative UCVA was 20/30 and remained for 1 year's follow up. CONCLUSIONS: Here we reported a rare case of PHA combined with lens subluxation in China. After appropriate eye surgery, the patient achieved satisfying vision result in the right eye.


Subject(s)
Facial Hemiatrophy , Lens Subluxation , Phacoemulsification , Humans , Female , Facial Hemiatrophy/complications , Facial Hemiatrophy/diagnosis , Facial Hemiatrophy/surgery , Middle Aged , Lens Subluxation/surgery , Lens Subluxation/diagnosis , Lens Subluxation/etiology , Lens Implantation, Intraocular , Visual Acuity/physiology
14.
BMC Ophthalmol ; 24(1): 231, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38822280

ABSTRACT

BACKGROUND: The main purpose of this paper is to introduce a method that can accurately locate the posterior capsule of the lens to facilitate a relatively complete resection of the anterior vitreous body. METHODS: A total of 51 patients in the experimental group and control group were enrolled in this study. Phacoemulsification combined with vitrectomy was performed in all cases. After the cataract procedure was completed in the control group, the surgeon performed a conventional anterior vitrectomy with the operative eye. In the experimental group, anterior vitrectomy was performed according to the threadiness corrugation of the posterior capsule of the lens. During the operation, with the help of triamcinolone, two surgeons confirmed the resection of the anterior vitreous cortex; the best corrected visual acuity and intraocular pressure of all patients were recorded at 1 week, 1 month and 3 months after surgery. RESULTS: Fifty patients underwent phacoemulsification combined with vitrectomy, except one patient in the experimental group who was lost to follow-up. After surgery, no significant complications were observed in all patients except two patients in the control group with temporary increases in intraocular pressure. There was no significant difference in preoperative visual acuity between the two groups (t = 0.83, P = 0.25). Both groups had varying degrees of improvement in best corrected visual acuity at 1 week, 1 month and 3 months after surgery. Moreover, there was no significant difference in BCVA between the two groups at the three follow-up time points (t=-1.15, -1.65, -1.09, P = 0.53, 0.21, 0.23). After surgery, no significant complications were observed in all patients except two patients in the control group with temporary increases in intraocular pressure. Incomplete resection of the anterior vitreous cortex was observed in 2 patients in each group, but there was no significant difference (χ2 = 7.81, P > 0.05). CONCLUSION: In the process of cataract surgery combined with vitrectomy, thready corrugation appears in the posterior capsule of the lens and is an important sign of its localization. Anterior vitrectomy can be accomplished safely and effectively with the help of thread-like corrugation, and the surgical effect is almost the same as that of traditional surgery. Especially suitable for beginners in vitreous surgery.


Subject(s)
Intraocular Pressure , Phacoemulsification , Visual Acuity , Vitrectomy , Vitreous Body , Humans , Vitrectomy/methods , Phacoemulsification/methods , Female , Male , Aged , Middle Aged , Vitreous Body/surgery , Intraocular Pressure/physiology , Posterior Capsule of the Lens/surgery , Aged, 80 and over
15.
Indian J Ophthalmol ; 72(6): 916-918, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38767550

ABSTRACT

Phacoemulsification in hard cataracts is a challenge. The use of dispersive ophthalmic viscosurgical devices (OVDs) to protect the endothelium is a routine step in such scenarios. However, as OVD is transparent, it is difficult to spot within the anterior chamber. Therefore, surgeons may not be aware when the OVD coating of the endothelium disappears during surgery. Consequently, there may be too frequent OVD injections, resulting in a waste of resources. On the contrary, the surgeon may fail to inject OVD at an appropriate time, leading to greater endothelial damage. We propose a novel technique of using an air bubble as a guide that helps in identifying the time when OVD disappears from the anterior chamber, thereby suggesting the surgeon to reinject before proceeding further.


Subject(s)
Air , Phacoemulsification , Viscosupplements , Humans , Phacoemulsification/methods , Viscosupplements/administration & dosage , Hyaluronic Acid/administration & dosage , Endothelium, Corneal/pathology , Anterior Chamber
17.
BMJ Case Rep ; 17(5)2024 May 27.
Article in English | MEDLINE | ID: mdl-38802253

ABSTRACT

A female in her 20s presented with a diminution of vision in the right eye (RE) following an open globe injury (scleral penetration) and repair a year back. At the presentation, she had low intraocular pressure (IOP) of 7 mm Hg, posterior subcapsular cataract (PSC), retrolental vitreous bands incarcerated at the penetration site, disc oedema, tortuous vessels and choroidal folds. Inferotemporal and superonasal cyclodialysis clefts were detected on CASIA 2 optical coherence tomography (OCT). The diagnosis of RE repaired scleral penetration, PSC and cyclodialysis cleft with hypotony maculopathy was made. The case was managed by phacoemulsification with an intraocular lens in the bag and a capsular tension ring in the sulcus, as a tamponading agent to close the cleft. Intraoperatively on endoscopic visualisation, vitreous membrane was noticed encasing the ciliary processes causing a tractional cyclodialysis and hence single port 23G pars plana vitrectomy was performed to relieve the traction. Postsurgery, IOP was 14 mm Hg, and the repaired cleft was visualised on anterior segment OCT.


Subject(s)
Cyclodialysis Clefts , Tomography, Optical Coherence , Vitrectomy , Adult , Female , Humans , Cyclodialysis Clefts/surgery , Cyclodialysis Clefts/etiology , Endotamponade/methods , Eye Injuries, Penetrating/surgery , Eye Injuries, Penetrating/complications , Intraocular Pressure/physiology , Phacoemulsification , Sclera/surgery , Vitrectomy/methods
19.
BMC Ophthalmol ; 24(1): 212, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38750496

ABSTRACT

BACKGROUND: To evaluate differences in log MAR best-corrected visual acuity (BCVA) improvement and postoperative central foveal thickness (CFT) and choroidal thickness (CT) changes between conventional phacoemulsification surgery (CPS) and femtosecond laser-assisted cataract surgery (FLACS) for high-myopia cataracts. METHODS: This was a retrospective and observational study. One hundred and two eyes of 102 patients with high-myopia cataracts were examined. CPS was performed in 54 eyes, and FLACS was performed in 48 eyes. All eyes underwent logMAR BCVA, CFT and CT of three different sectors preoperatively and one week and six months postoperatively. RESULTS: The logMAR BCVA improved significantly after surgery in both groups (both P < 0.001), but no difference was observed in BCVA improvement between the groups (P = 0.554). Moreover, no significant differences were reflected in the changes in CFT, nasal 1 mm CT or temporal 1 mm CT between the two groups, and only subfoveal choroidal thickness (SFCT) in the CPS group decreased significantly compared with that in the FLACS group at any postoperative time (P = 0.003 and 0.026). AL, preoperative logMAR BCVA, and CT of the three regions exhibited a notable correlation with postoperative BCVA (all P < 0.05) according to univariate logistic regression analysis. However, only the AL, preoperative logMAR BCVA and SFCT remained significant in the multivariate model. Postoperative logMAR BCVA revealed a positive correlation with AL and preoperative logMAR BCVA but a negative correlation with SFCT. CONCLUSIONS: FLACS was not superior to CPS in improving BCVA but had less impact on SFCT in the treatment of high-myopia cataracts. Eyes with a longer AL, worse preoperative logMAR BCVA and thinner SFCT had a high risk of worse postoperative BCVA.


Subject(s)
Cataract , Laser Therapy , Phacoemulsification , Tomography, Optical Coherence , Visual Acuity , Humans , Retrospective Studies , Female , Male , Phacoemulsification/methods , Visual Acuity/physiology , Middle Aged , Aged , Laser Therapy/methods , Cataract/complications , Cataract/physiopathology , Tomography, Optical Coherence/methods , Macula Lutea/diagnostic imaging , Macula Lutea/pathology , Cataract Extraction/methods , Myopia, Degenerative/physiopathology , Myopia, Degenerative/surgery , Myopia, Degenerative/complications , Choroid/diagnostic imaging , Treatment Outcome
20.
Vestn Oftalmol ; 140(2. Vyp. 2): 123-128, 2024.
Article in Russian | MEDLINE | ID: mdl-38739141

ABSTRACT

Effective and atraumatic removal of a soft lens nucleus requires different surgical techniques compared to phacoemulsification of a dense nucleus. PURPOSE: This study was conducted to develop a non-ultrasound technique for emulsification of a soft lens nucleus. MATERIAL AND METHODS: Fifty-seven patients (57 eyes) underwent surgery. In 23 cases, early or immature cataracts were detected, and in 34 cases, lens removal was performed for refractive purposes in high myopia and complex myopic astigmatism. Phacoemulsifier Centurion Vision System (Alcon Laboratories, Inc., USA) was used for the surgery. Aspiration of soft lens nucleus was done using a rotational technique. The following aspects were evaluated in the course of the surgery: the volume of the required irrigation solution, and the frequency needing to involve ultrasound for complete emulsification of the lens nucleus. Intraoperative and postoperative complications were also assessed. RESULTS: The surgery was uneventful in all cases. There were no violations of the integrity of capsulorhexis edge. The need for short pulses of minimal power ultrasound during the removal of the soft lens using this technique arose only in 11 (19.3%) cases. The effective ultrasound time was less than 1 second. The required volume of irrigation solution was 33.0 (24.0; 43.0) ml, which does not differ significantly from that in ultrasonic phacoemulsification. CONCLUSIONS: The use of modern phacoemulsifiers providing a high vacuum level allows successful removal of a soft lens without using ultrasound, which prevents its negative impact on the ocular tissues. The use of adequate surgical techniques, including the optimal direction of rotation of the lens nucleus in the rotational technique, improves the efficiency of soft lens nucleus removal.


Subject(s)
Phacoemulsification , Humans , Male , Female , Phacoemulsification/methods , Middle Aged , Cataract , Treatment Outcome , Lens Nucleus, Crystalline/surgery , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...