Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.264
Filter
1.
Opt Lett ; 49(11): 3054-3057, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38824326

ABSTRACT

Photoacoustic imaging (PAI) utilizes the photoacoustic effect to record both vascular and functional characteristics of a biological tissue. Photoacoustic signals have typically low amplitude that cannot be read efficiently by data acquisition systems. This necessitates the use of one or more amplifiers. These amplifiers are somewhat bulky (e.g., the ZFL-500LN+, Mini-Circuits, USA, or 351A-3-50-NI, Analog Modules Inc., USA). Here, we describe the fabrication and development process of a transducer with a built-in low-noise preamplifier that is encased within the transducer housing. This new, to the best of our knowledge, design could be advantageous for applications where a compact transducer + preamplifier is required. We demonstrate the performance of this compact detection unit in a laser scanning photoacoustic microscopy system by imaging a rat ear ex vivo and a rat brain vasculature in vivo.


Subject(s)
Equipment Design , Photoacoustic Techniques , Transducers , Photoacoustic Techniques/instrumentation , Photoacoustic Techniques/methods , Animals , Rats , Miniaturization , Brain/diagnostic imaging , Brain/blood supply , Ear/diagnostic imaging , Ear/blood supply , Amplifiers, Electronic
2.
ACS Appl Mater Interfaces ; 16(20): 25879-25891, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38718301

ABSTRACT

Biological imaging-guided targeted tumor therapy has been a soughtafter goal in the field of cancer diagnosis and treatment. To this end, we proposed a strategy to modulate surface plasmon resonance and endow WO3-x nanoparticles (NPs) with enzyme-like catalytic properties by doping Fe2+ in the structure of the NPs. Doping of the Fe2+ introduced oxygen vacancies into the structure of the NPs, inducing a red shift of the maximum absorption wavelength into the near-infrared II (NIR-II) region and enhancing the photoacoustic (PA) and photothermal properties of the NPs for more effective imaging-guided cancer therapy. Under NIR-II laser irradiation, the Fe-WO3-x NPs produced very strong NIR-II PA and photothermal effects, which significantly enhanced the PA imaging and photothermal treatment effects. On the other hand, Fe2+ in Fe-WO3-x could undergo Fenton reactions with H2O2 in the tumor tissue to generate ·OH for chemodynamic therapy. In addition, Fe-WO3-x can also catalyze the above reactions to produce more reactive oxygen species (ROS) and induce the oxidation of NADH to interfere with intracellular adenosine triphosphate (ATP) synthesis, thereby further improving the efficiency of cancer therapy. Specific imaging of tumor tissue and targeted synergistic therapy was achieved after ligation of a MUC1 aptamer to the surface of the Fe-WO3-x NPs by the complexing of -COOH in MUC1 with tungsten ions on the surface of the NPs. These results demonstrated that Fe-WO3-x NPs could be a promising diagnosis and therapeutic agent for cancer. Such a study opens up new avenues into the rational design of nanodiagnosis and treatment agents for NIR-II PA imaging and cancer therapy.


Subject(s)
Photoacoustic Techniques , Surface Plasmon Resonance , Tungsten , Animals , Humans , Mice , Tungsten/chemistry , Infrared Rays , Oxides/chemistry , Neoplasms/diagnostic imaging , Neoplasms/therapy , Neoplasms/drug therapy , Nanoparticles/chemistry , Nanoparticles/therapeutic use , Cell Line, Tumor , Reactive Oxygen Species/metabolism
3.
ACS Appl Mater Interfaces ; 16(20): 25856-25868, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38726921

ABSTRACT

Artificial peroxisomes (AP) with enzyme-mimetic catalytic activity and recruitment ability have drawn a great deal of attention in fabricating protocell systems for scavenging reactive oxygen species (ROS), modulating the inflammatory microenvironment, and reprogramming macrophages, which is of great potential in treating inflammatory diseases such as rheumatoid arthritis (RA). Herein, a macrophage membrane-cloaked Cu-coordinated polyphthalocyanine-based AP (CuAP) is prepared with a macrocyclic conjugated polymerized network and embedded Cu-single atomic active center, which mimics the catalytic activity and coordination environment of natural superoxide dismutase and catalase, possesses the inflammatory recruitment ability of macrophages, and performs photoacoustic imaging (PAI)-guided treatment. The results of both in vitro cellular and in vivo animal experiments demonstrated that the CuAP under ultrasound and microbubbles could efficiently scavenge excess ROS in cells and tissues, modulate microenvironmental inflammatory cytokines such as interleukin-1ß, tumor necrosis factor-α, and arginase-1, and reprogram macrophages by polarization of M1 (proinflammatory phenotype) to M2 (anti-inflammatory phenotype). We believe this study offers a proof of concept for engineering multifaceted AP and a promising approach for a PAI-guided treatment platform for RA.


Subject(s)
Arthritis, Rheumatoid , Macrophages , Photoacoustic Techniques , Animals , Macrophages/metabolism , Mice , Arthritis, Rheumatoid/diagnostic imaging , Arthritis, Rheumatoid/therapy , RAW 264.7 Cells , Reactive Oxygen Species/metabolism , Humans , Copper/chemistry , Copper/pharmacology
4.
J Environ Manage ; 359: 120954, 2024 May.
Article in English | MEDLINE | ID: mdl-38692026

ABSTRACT

Plastic products' widespread applications and their non-biodegradable nature have resulted in the continuous accumulation of microplastic waste, emerging as a significant component of ecological environmental issues. In the field of microplastic detection, the intricate morphology poses challenges in achieving rapid visual characterization of microplastics. In this study, photoacoustic imaging technology is initially employed to capture high-resolution images of diverse microplastic samples. To address the limited dataset issue, an automated data processing pipeline is designed to obtain sample masks while effectively expanding the dataset size. Additionally, we propose Vqdp2, a generative deep learning model with multiple proxy tasks, for predicting six forms of microplastics data. By simultaneously constraining model parameters through two training modes, outstanding morphological category representations are achieved. The results demonstrate Vqdp2's excellent performance in classification accuracy and feature extraction by leveraging the advantages of multi-task training. This research is expected to be attractive for the detection classification and visual characterization of microplastics.


Subject(s)
Deep Learning , Microplastics , Photoacoustic Techniques , Microplastics/analysis , Photoacoustic Techniques/methods , Environmental Monitoring/methods , Plastics
5.
Opt Lett ; 49(9): 2341-2344, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38691714

ABSTRACT

In the fields of biomedicine and microfluidics, the non-contact capture, manipulation, and spin of micro-particles hold great importance. In this study, we propose a programmable non-contact manipulation technique that utilizes photoacoustic effect to spin and transport living shrimp eggs. By directing a modulated pulsed laser toward a liquid-covered stainless-steel membrane, we can excite patterned Lamb waves within the membrane. These Lamb waves occur at the interface between the membrane and the liquid, enabling the manipulation of nearby particles. Experimental results demonstrate the successful capture, spin, and transport of shrimp eggs in diameter of 220 µm over a distance of about 5 mm. Calculations indicate that the acoustic radiation force and torque generated by our photoacoustic manipulation system are more than 299.5 nN and 41.0 nN·mm, respectively. The system surpasses traditional optical tweezers in terms of force and traditional acoustic tweezers in terms of flexibility. Consequently, this non-contact manipulation system significantly expands the possibilities for applications in various fields, including embryo screening, cell manipulation, and microfluidics.


Subject(s)
Ovum , Photoacoustic Techniques , Animals , Photoacoustic Techniques/methods , Pressure , Optical Tweezers , Penaeidae
6.
Sci Rep ; 14(1): 10597, 2024 05 08.
Article in English | MEDLINE | ID: mdl-38719924

ABSTRACT

Parotid lumps are a heterogeneous group of mainly benign but also malignant tumors. Preoperative imaging does not allow a differentiation between tumor types. Multispectral optoacoustic tomography (MSOT) may improve the preoperative diagnostics. In this first prospective pilot trial the ability of MSOT to discriminate between the two most frequent benign parotid tumors, pleomorphic adenoma (PA) and Warthin tumor (WT) as well as to normal parotid tissue was explored. Six wavelengths (700, 730, 760, 800, 850, 900 nm) and the parameters deoxygenated (HbR), oxygenated (HbO2), total hemoglobin (HbT), and saturation of hemoglobin (sO2) were analyzed. Ten patients with PA and fourteen with WT were included (12/12 female/male; median age: 51 years). For PA, the mean values for all measured wave lengths as well as for the hemoglobin parameters were different for the tumors compared to the healthy parotid (all p < 0.05). The mean MSOT parameters were all significantly higher (all p < 0.05) in the WT compared to healthy parotid gland except for HbT and sO2. Comparing both tumors directly, the mean values of MSOT parameters were not different between PA and WT (all p > 0.05). Differences were seen for the maximal MSOT parameters. The maximal tumor values for 900 nm, HbR, HbT, and sO2 were lower in PA than in WT (all p < 0.05). This preliminary MSOT parotid tumor imaging study showed clear differences for PA or WT compared to healthy parotid tissue. Some MSOT characteristics of PA and WT were different but needed to be explored in larger studies.


Subject(s)
Parotid Neoplasms , Photoacoustic Techniques , Humans , Female , Parotid Neoplasms/diagnostic imaging , Parotid Neoplasms/pathology , Middle Aged , Male , Pilot Projects , Prospective Studies , Photoacoustic Techniques/methods , Adult , Aged , Hemoglobins/analysis , Hemoglobins/metabolism , Adenolymphoma/diagnostic imaging , Adenolymphoma/pathology , Adenoma, Pleomorphic/diagnostic imaging , Adenoma, Pleomorphic/pathology , Tomography/methods , Parotid Gland/diagnostic imaging , Parotid Gland/pathology
7.
Anal Chem ; 96(22): 9132-9140, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38764163

ABSTRACT

Gold nanorods (AuNRs) have been considered highly compelling materials for early cancer diagnosis and have aroused a burgeoning fascination among the biomedical sectors. By leveraging the versatile tunable optical properties of AuNRs, herein, we have developed a novel tumor-targeted dual-modal nanoprobe (FFA) that exhibits excellent bioluminescence and photoacoustic imaging performance for early tumor diagnosis. FFA has been synthesized by anchoring the recombinant bioluminescent firefly luciferase protein (Fluc) on the folate-conjugated AuNRs via the PEG linker. TEM images and UV-vis studies confirm the nanorod morphology and successful conjugation of the biomolecules to AuNRs. The nanoprobe FFA relies on the ability of the folate module to target the folate receptor-positive tumor cells actively, and simultaneously, the Fluc module facilitates excellent bioluminescent properties in physiological conditions. The success of chemical engineering in the present study enables stronger bioluminescent signals in the folate receptor-positive cells (Skov3, Hela, and MCF-7) than in folate receptor-negative cells (A549, 293T, MCF-10A, and HepG2). Additionally, the AuNRs induced strong photoacoustic conversion performance, enhancing the resolution of tumor imaging. No apparent toxicity was detected at the cellular and mouse tissue levels, manifesting the biocompatibility nature of the nanoprobe. Prompted by the positive merits of FFA, the in vivo animal studies were performed, and a notable enhancement was observed in the bioluminescent/photoacoustic intensity of the nanoprobe in the tumor region compared to that in the folate-blocking region. Therefore, this synergistic dual-modal bioluminescent and photoacoustic imaging platform holds great potential as a tumor-targeted contrast agent for early tumor diagnosis with high-performance imaging information.


Subject(s)
Contrast Media , Gold , Luminescent Measurements , Nanotubes , Photoacoustic Techniques , Photoacoustic Techniques/methods , Humans , Nanotubes/chemistry , Gold/chemistry , Animals , Contrast Media/chemistry , Mice , Mice, Nude , Optical Imaging , Neoplasms/diagnostic imaging , Female , Luciferases/chemistry , Luciferases/metabolism
8.
Opt Lett ; 49(10): 2637-2640, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748124

ABSTRACT

Optical-resolution photoacoustic microscopy (OR-PAM) excels in precisely imaging a biological tissue based on absorption contrast. However, existing OR-PAMs are confined by fixed compromises between spatial resolution and field of view (FOV), preventing the integration of large FOV and local high-resolution within one system. Here, we present a non-telecentric OR-PAM (nTC-PAM) that empowers efficient adaptation of FOV and spatial resolution to match the multi-scale requirement of diverse biological imaging. Our method allows for a large-scale transformation in FOV and even surpassing the nominal FOV of the objective with minimal marginal degradation of the lateral resolution. We demonstrate the advantage of nTC-PAM through multi-scale imaging of the leaf phantom, mouse ear, and cortex. The results reveal that nTC-PAM can switch the FOV and spatial resolution to meet the requirements of different biological tissues, such as large-scale imaging of the whole cerebral cortex and high-resolution imaging of microvascular structures in local brain regions.


Subject(s)
Microscopy , Photoacoustic Techniques , Photoacoustic Techniques/methods , Animals , Mice , Microscopy/methods , Ear/diagnostic imaging , Ear/blood supply , Phantoms, Imaging
9.
Analyst ; 149(11): 3064-3072, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38712864

ABSTRACT

Ratiometric near-infrared fluorescent pH probes with various pKa values were innovatively designed and synthesized based on cyanine with a diamine moiety. The photochemical properties of these probes were thoroughly evaluated. Among the series, IR-PHA exhibited an optimal pKa value of approximately 6.40, closely matching the pH of cancerous tissues. This feature is particularly valuable for real-time pH monitoring in both living cells and living mice. Moreover, when administered intravenously to tumor-bearing mice, IR-PHA demonstrated rapid and significant enhancement of near-infrared fluorescence and photoacoustic signals within the tumor region. This outcome underscores the probe's exceptional capability for dual-modal cancer imaging utilizing near-infrared fluorescence (NIRF) and photoacoustic (PA) modalities. Concurrently, the application of a continuous-wave near-infrared laser efficiently ablated cancer cells in vivo, attributed to the photothermal effect induced by IR-PHA. The results strongly indicate that IR-PHA is well-suited for NIRF/PA dual-modality imaging and photothermal therapy of tumors. This makes it a promising candidate for theranostic applications involving small molecules.


Subject(s)
Fluorescent Dyes , Infrared Rays , Photoacoustic Techniques , Photothermal Therapy , Animals , Photoacoustic Techniques/methods , Humans , Mice , Fluorescent Dyes/chemistry , Fluorescent Dyes/chemical synthesis , Fluorescent Dyes/radiation effects , Photothermal Therapy/methods , Neoplasms/diagnostic imaging , Neoplasms/therapy , Hydrogen-Ion Concentration , Cell Line, Tumor , Mice, Nude , Optical Imaging/methods , Female
10.
Anal Chem ; 96(21): 8689-8695, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38748889

ABSTRACT

Tumor microenvironment-responsive phototheranostic agents are highly sought after for their ability to improve diagnostic accuracy and treatment specificity. Here, we introduce a novel single-molecule probe, POZ-NO, which is activated by nitric oxide (NO) and weak acidity, enabling dual-mode imaging and photothermal therapy (PTT) of tumors. In acidic environments with elevated NO levels, POZ-NO exhibits a distinctive ratiometric fluorescence signal shift from the red to near-infrared, accompanied by a 700 nm photoacoustic signal. Additionally, POZ-NO demonstrated potent photothermal effects upon NO and acidity activation, achieving an impressive conversion efficiency of 74.3% under 735 nm laser irradiation. In vivo studies confirm POZ-NO's ability to accurately image tumors through ratiometric fluorescence and photoacoustic modes while selectively treating tumors with PTT.


Subject(s)
Nitric Oxide , Photoacoustic Techniques , Photothermal Therapy , Tumor Microenvironment , Nitric Oxide/analysis , Nitric Oxide/metabolism , Nitric Oxide/chemistry , Animals , Humans , Mice , Optical Imaging , Hydrogen-Ion Concentration , Theranostic Nanomedicine , Mice, Inbred BALB C , Female , Fluorescent Dyes/chemistry , Fluorescence
11.
Front Immunol ; 15: 1372996, 2024.
Article in English | MEDLINE | ID: mdl-38817606

ABSTRACT

Tissue microenvironments during physiology and pathology are highly complex, meaning dynamic cellular activities and their interactions cannot be accurately modelled ex vivo or in vitro. In particular, tissue-specific resident cells which may function and behave differently after isolation and the heterogenous vascular beds in various organs highlight the importance of observing such processes in real-time in vivo. This challenge gave rise to intravital microscopy (IVM), which was discovered over two centuries ago. From the very early techniques of low-optical resolution brightfield microscopy, limited to transparent tissues, IVM techniques have significantly evolved in recent years. Combined with improved animal surgical preparations, modern IVM technologies have achieved significantly higher speed of image acquisition and enhanced image resolution which allow for the visualisation of biological activities within a wider variety of tissue beds. These advancements have dramatically expanded our understanding in cell migration and function, especially in organs which are not easily accessible, such as the brain. In this review, we will discuss the application of rodent IVM in neurobiology in health and disease. In particular, we will outline the capability and limitations of emerging technologies, including photoacoustic, two- and three-photon imaging for brain IVM. In addition, we will discuss the use of these technologies in the context of neuroinflammation.


Subject(s)
Brain , Intravital Microscopy , Animals , Intravital Microscopy/methods , Humans , Photoacoustic Techniques/methods
12.
Biomacromolecules ; 25(5): 3153-3162, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38693895

ABSTRACT

A photoacoustic (PA) imaging technique using the second near-infrared (NIR-II) window has attracted more and more attention because of its merits of deeper penetration depth and higher signal-to-noise (S/N) ratio than that using the first near-infrared (NIR-I) one. However, the design and development of high-performance PA imaging contrast agents in the NIR-II window is still a challenge. A semiconducting polymer, constructed by asymmetric units, exhibits regiorandom characteristics that effectively increase the distortion of the backbone. This increase in the degree of twist can regulate the twisted intramolecular charge transfer (TICT) effect, resulting in an enhancement of the PA signal. In this paper, an asymmetric structural acceptor strategy is developed to improve the PA signals of the resulting semiconducting polymer (PATQ-MP) in the NIR-II window with improved brightness, higher S/N ratio, and better photothermal conversion efficiency compared to polymers with the same main-chain structure containing a symmetric acceptor. DFT analysis showed that PATQ-MP containing an asymmetric acceptor monomer had a larger dihedral angle, which effectively improved the PA signal intensity by enhancing the TICT effect. The PEG-encapsulated PATQ-MP nanoparticles exhibit promising performance in the PA imaging of mouse tumors in vivo, demonstrating the clear identification of microvessels as small as 100 µm along with rapid metabolism within a span of 5 h. Therefore, this work provides a unique molecular design strategy for improving the signal intensity of PA imaging in the NIR-II window.


Subject(s)
Photoacoustic Techniques , Polymers , Semiconductors , Photoacoustic Techniques/methods , Animals , Mice , Polymers/chemistry , Quinoxalines/chemistry , Female , Humans , Thiadiazoles/chemistry , Infrared Rays , Mice, Nude , Mice, Inbred BALB C , Contrast Media/chemistry
13.
Sensors (Basel) ; 24(9)2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38732775

ABSTRACT

Photoacoustic imaging (PAI) is a rapidly developing emerging non-invasive biomedical imaging technique that combines the strong contrast from optical absorption imaging and the high resolution from acoustic imaging. Abnormal biological tissues (such as tumors and inflammation) generate different levels of thermal expansion after absorbing optical energy, producing distinct acoustic signals from normal tissues. This technique can detect small tissue lesions in biological tissues and has demonstrated significant potential for applications in tumor research, melanoma detection, and cardiovascular disease diagnosis. During the process of collecting photoacoustic signals in a PAI system, various factors can influence the signals, such as absorption, scattering, and attenuation in biological tissues. A single ultrasound transducer cannot provide sufficient information to reconstruct high-precision photoacoustic images. To obtain more accurate and clear image reconstruction results, PAI systems typically use a large number of ultrasound transducers to collect multi-channel signals from different angles and positions, thereby acquiring more information about the photoacoustic signals. Therefore, to reconstruct high-quality photoacoustic images, PAI systems require a significant number of measurement signals, which can result in substantial hardware and time costs. Compressed sensing is an algorithm that breaks through the Nyquist sampling theorem and can reconstruct the original signal with a small number of measurement signals. PAI based on compressed sensing has made breakthroughs over the past decade, enabling the reconstruction of low artifacts and high-quality images with a small number of photoacoustic measurement signals, improving time efficiency, and reducing hardware costs. This article provides a detailed introduction to PAI based on compressed sensing, such as the physical transmission model-based compressed sensing method, two-stage reconstruction-based compressed sensing method, and single-pixel camera-based compressed sensing method. Challenges and future perspectives of compressed sensing-based PAI are also discussed.


Subject(s)
Algorithms , Photoacoustic Techniques , Photoacoustic Techniques/methods , Humans , Image Processing, Computer-Assisted/methods , Diagnostic Imaging/methods , Transducers
14.
Nat Commun ; 15(1): 4228, 2024 May 18.
Article in English | MEDLINE | ID: mdl-38762498

ABSTRACT

Cross-modal analysis of the same whole brain is an ideal strategy to uncover brain function and dysfunction. However, it remains challenging due to the slow speed and destructiveness of traditional whole-brain optical imaging techniques. Here we develop a new platform, termed Photoacoustic Tomography with Temporal Encoding Reconstruction (PATTERN), for non-destructive, high-speed, 3D imaging of ex vivo rodent, ferret, and non-human primate brains. Using an optimally designed image acquisition scheme and an accompanying machine-learning algorithm, PATTERN extracts signals of genetically-encoded probes from photobleaching-based temporal modulation and enables reliable visualization of neural projection in the whole central nervous system with 3D isotropic resolution. Without structural and biological perturbation to the sample, PATTERN can be combined with other whole-brain imaging modalities to acquire the whole-brain image with both high resolution and morphological fidelity. Furthermore, cross-modal transcriptome analysis of an individual brain is achieved by PATTERN imaging. Together, PATTERN provides a compatible and versatile strategy for brain-wide cross-modal analysis at the individual level.


Subject(s)
Brain , Ferrets , Imaging, Three-Dimensional , Photoacoustic Techniques , Animals , Brain/diagnostic imaging , Photoacoustic Techniques/methods , Imaging, Three-Dimensional/methods , Mice , Algorithms , Machine Learning , Tomography/methods , Image Processing, Computer-Assisted/methods , Rats , Male
15.
Acc Chem Res ; 57(11): 1595-1607, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38759211

ABSTRACT

ConspectusHigh-precision neuromodulation plays a pivotal role in elucidating fundamental principles of neuroscience and treating specific neurological disorders. Optical neuromodulation, enabled by spatial resolution defined by the diffraction limit at the submicrometer scale, is a general strategy to achieve such precision. Optogenetics offers single-neuron spatial resolution with cellular specificity, whereas the requirement of genetic transfection hinders its clinical application. Direct photothermal modulation, an alternative nongenetic optical approach, often associates a large temperature increase with the risk of thermal damage to surrounding tissues.Photoacoustic (also called optoacoustic) neural stimulation is an emerging technology for neural stimulation with the following key features demonstrated. First, the photoacoustic approach demonstrated high efficacy without the need for genetic modification. The generated pulsed ultrasound upon ns laser pulses with energy ranging from a few µJ to tens of µJ is sufficient to activate wild-type neurons. Second, the photoacoustic approach provides sub-100-µm spatial precision. It overcomes the fundamental wave diffraction limit of ultrasound by harnessing the localized ultrasound field generated through light absorption. A spatial precision of 400 µm has been achieved in rodent brains using a fiber-based photoacoustic emitter. Single-cell stimulation in neuronal cultures in vitro and in brain slices ex vivo is achieved using tapered fiber-based photoacoustic emitters. This precision is 10 to 100 times better than that for piezo-based low-frequency ultrasound and is essential to pinpoint a specific region or cell population in a living brain. Third, compared to direct photothermal stimulation via temperature increase, photoacoustic stimulation requires 40 times less laser energy dose to evoke neuron activities and is associated with a minimal temperature increase of less than 1 °C, preventing potential thermal damage to neurons. Fourth, photoacoustics is a versatile approach and can be designed in various platforms aiming at specific applications. Our team has shown the design of fiber-based photoacoustic emitters, photoacoustic nanotransducers, soft biocompatible photoacoustic films, and soft photoacoustic lenses. Since they interact with neurons through ultrasound without the need for direct contact, photoacoustic enables noninvasive transcranial and dura-penetrating brain stimulation without compromising high precision.In this Account, we will first review the basic principles of photoacoustic and discuss the key design elements of PA transducers for neural modulation guided by the principle. We will also highlight how these design goals were achieved from a materials chemistry perspective. The design of different PA interfaces, their unique capability, and their applications in neural systems will be reviewed. In the end, we will discuss the remaining challenges and future perspectives for this technology.


Subject(s)
Neurons , Photoacoustic Techniques , Photoacoustic Techniques/methods , Animals , Humans , Optogenetics/methods , Brain/diagnostic imaging
16.
Opt Lett ; 49(7): 1725-1728, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38560847

ABSTRACT

Ultrasound coupling is one of the critical challenges for traditional photoacoustic (or optoacoustic) microscopy (PAM) techniques transferred to the clinical examination of chronic wounds and open tissues. A promising alternative potential solution for breaking the limitation of ultrasound coupling in PAM is photoacoustic remote sensing (PARS), which implements all-optical non-interferometric photoacoustic measurements. Functional imaging of PARS microscopy was demonstrated from the aspects of histopathology and oxygen metabolism, while its performance in hemodynamic quantification remains unexplored. In this Letter, we present an all-optical thermal-tagging flowmetry approach for PARS microscopy and demonstrate it with comprehensive mathematical modeling and ex vivo and in vivo experimental validations. Experimental results demonstrated that the detectable range of the blood flow rate was from 0 to 12 mm/s with a high accuracy (measurement error:±1.2%) at 10-kHz laser pulse repetition rate. The proposed all-optical thermal-tagging flowmetry offers an effective alternative approach for PARS microscopy realizing non-contact dye-free hemodynamic imaging.


Subject(s)
Photoacoustic Techniques , Remote Sensing Technology , Photoacoustic Techniques/methods , Rheology/methods , Ultrasonography/methods , Microscopy/methods
17.
J Biomed Opt ; 29(Suppl 1): S11530, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38632983

ABSTRACT

Significance: In the photoacoustic (PA) technique, the laser irradiation in the time domain (i.e., laser pulse duration) governs the characteristics of PA imaging-it plays a crucial role in the optical-acoustic interaction, the generation of PA signals, and the PA imaging performance. Aim: We aim to provide a comprehensive analysis of the impact of laser pulse duration on various aspects of PA imaging, encompassing the signal-to-noise ratio, the spatial resolution of PA imaging, the acoustic frequency spectrum of the acoustic wave, the initiation of specific physical phenomena, and the photothermal-PA (PT-PA) interaction/conversion. Approach: By surveying and reviewing the state-of-the-art investigations, we discuss the effects of laser pulse duration on the generation of PA signals in the context of biomedical PA imaging with respect to the aforementioned aspects. Results: First, we discuss the impact of laser pulse duration on the PA signal amplitude and its correlation with the lateral resolution of PA imaging. Subsequently, the relationship between the axial resolution of PA imaging and the laser pulse duration is analyzed with consideration of the acoustic frequency spectrum. Furthermore, we examine the manipulation of the pulse duration to trigger physical phenomena and its relevant applications. In addition, we elaborate on the tuning of the pulse duration to manipulate the conversion process and ratio from the PT to PA effect. Conclusions: We contribute to the understanding of the physical mechanisms governing pulse-width-dependent PA techniques. By gaining insight into the mechanism behind the influence of the laser pulse, we can trigger the pulse-with-dependent physical phenomena for specific PA applications, enhance PA imaging performance in biomedical imaging scenarios, and modulate PT-PA conversion by tuning the pulse duration precisely.


Subject(s)
Light , Photoacoustic Techniques , Spectrum Analysis , Signal-To-Noise Ratio , Acoustics , Lasers , Photoacoustic Techniques/methods
18.
Lasers Med Sci ; 39(1): 112, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38656634

ABSTRACT

PURPOSE: To measure the dynamic characteristics of the flow field in a complex root canal model activated by two laser-activated irrigation (LAI) modalities at different activation energy outputs: photon-induced photoacoustic streaming (PIPS) and microshort pulse (MSP). METHODS: A phase-locked micro-scale Particle Image Velocimetry (µPIV) system was employed to characterise the temporal variations of LAI-induced velocity fields in the root canal following a single laser pulse. The wall shear stress (WSS) in the lateral root canal was subsequently estimated from the phase-averaged velocity fields. RESULTS: Both PIPS and MSP were able to generate the 'breath mode' of the irrigant current under all tested conditions. The transient irrigation flush in the root canal peaked at speeds close to 6 m/s. However, this intense flushing effect persisted for only about 2000 µs (or 3% of a single laser-pulse activation cycle). For MSP, the maximum WSS magnitude was approximately 3.08 Pa at an activation energy of E = 20 mJ/pulse, rising to 9.01 Pa at E = 50 mJ/pulse. In comparison, PIPS elevated the WSS to 10.63 Pa at E = 20 mJ/pulse. CONCLUSION: Elevating the activation energy can boost the peak flushing velocity and the maximum WSS, thereby enhancing irrigation efficiency. Given the same activation energy, PIPS outperforms MSP. Additionally, increasing the activation frequency may be an effective strategy to improve irrigation performance further.


Subject(s)
Rheology , Humans , Dental Pulp Cavity/radiation effects , Therapeutic Irrigation/methods , Therapeutic Irrigation/instrumentation , Lasers , Root Canal Irrigants , Photoacoustic Techniques/methods , Root Canal Preparation/methods , Root Canal Preparation/instrumentation
19.
ACS Sens ; 9(4): 2166-2175, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38625680

ABSTRACT

Relying on the strong optical absorption of hemoglobin to pulsed laser energy, photoacoustic microscopy provides morphological and functional information on microvasculature label-freely. Here, we propose speckle variance photoacoustic microscopy (SV-PAM), which harnesses intrinsic imaging contrast from temporal-varied photoacoustic signals of moving red blood cells in blood vessels, for recovering three-dimension hemodynamic images down to capillary-level resolution within the microcirculatory tissue beds in vivo. Calculating the speckle variance of consecutive photoacoustic B-scan frames acquired at the same lateral position enables accurate identification of blood perfusion and occlusion, which provides interpretations of dynamic blood flow in the microvasculature, in addition to the microvascular anatomic structures. We demonstrate high-resolution hemodynamic imaging of vascular occlusion and reperfusion in the microvasculature of mice ears in vivo. The results suggest that our SV-PAM is potentially invaluable for biomedical hemodynamic investigations, for example, imaging ischemic stroke and hemorrhagic stroke.


Subject(s)
Microscopy , Photoacoustic Techniques , Photoacoustic Techniques/methods , Animals , Mice , Microscopy/methods , Hemodynamics/physiology , Ear/blood supply , Ear/diagnostic imaging , Microvessels/diagnostic imaging , Erythrocytes , Microcirculation
20.
J Biomed Opt ; 29(Suppl 1): S11529, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38650979

ABSTRACT

Significance: Compressed sensing (CS) uses special measurement designs combined with powerful mathematical algorithms to reduce the amount of data to be collected while maintaining image quality. This is relevant to almost any imaging modality, and in this paper we focus on CS in photoacoustic projection imaging (PAPI) with integrating line detectors (ILDs). Aim: Our previous research involved rather general CS measurements, where each ILD can contribute to any measurement. In the real world, however, the design of CS measurements is subject to practical constraints. In this research, we aim at a CS-PAPI system where each measurement involves only a subset of ILDs, and which can be implemented in a cost-effective manner. Approach: We extend the existing PAPI with a self-developed CS unit. The system provides structured CS matrices for which the existing recovery theory cannot be applied directly. A random search strategy is applied to select the CS measurement matrix within this class for which we obtain exact sparse recovery. Results: We implement a CS PAPI system for a compression factor of 4:3, where specific measurements are made on separate groups of 16 ILDs. We algorithmically design optimal CS measurements that have proven sparse CS capabilities. Numerical experiments are used to support our results. Conclusions: CS with proven sparse recovery capabilities can be integrated into PAPI, and numerical results support this setup. Future work will focus on applying it to experimental data and utilizing data-driven approaches to enhance the compression factor and generalize the signal class.


Subject(s)
Algorithms , Equipment Design , Image Processing, Computer-Assisted , Photoacoustic Techniques , Photoacoustic Techniques/methods , Photoacoustic Techniques/instrumentation , Image Processing, Computer-Assisted/methods , Data Compression/methods , Phantoms, Imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...