1.
Sensors (Basel) ; 24(9)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38732798

ABSTRACT

Photoplethysmography (PPG) is a non-invasive method used for cardiovascular monitoring, with multi-wavelength PPG (MW-PPG) enhancing its efficacy by using multiple wavelengths for improved assessment. This study explores how contact force (CF) variations impact MW-PPG signals. Data from 11 healthy subjects are analyzed to investigate the still understudied specific effects of CF on PPG signals. The obtained dataset includes simultaneous recording of five PPG wavelengths (470, 525, 590, 631, and 940 nm), CF, skin temperature, and the tonometric measurement derived from CF. The evolution of raw signals and the PPG DC and AC components are analyzed in relation to the increasing and decreasing faces of the CF. Findings reveal individual variability in signal responses related to skin and vasculature properties and demonstrate hysteresis and wavelength-dependent responses to CF changes. Notably, all wavelengths except 631 nm showed that the DC component of PPG signals correlates with CF trends, suggesting the potential use of this component as an indirect CF indicator. However, further validation is needed for practical application. The study underscores the importance of biomechanical properties at the measurement site and inter-individual variability and proposes the arterial pressure wave as a key factor in PPG signal formation.


Subject(s)
Photoplethysmography , Humans , Photoplethysmography/methods , Male , Adult , Female , Signal Processing, Computer-Assisted , Skin Temperature/physiology , Young Adult
2.
Sensors (Basel) ; 24(9)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38732827

ABSTRACT

Arterial blood pressure (ABP) serves as a pivotal clinical metric in cardiovascular health assessments, with the precise forecasting of continuous blood pressure assuming a critical role in both preventing and treating cardiovascular diseases. This study proposes a novel continuous non-invasive blood pressure prediction model, DSRUnet, based on deep sparse residual U-net combined with improved SE skip connections, which aim to enhance the accuracy of using photoplethysmography (PPG) signals for continuous blood pressure prediction. The model first introduces a sparse residual connection approach for path contraction and expansion, facilitating richer information fusion and feature expansion to better capture subtle variations in the original PPG signals, thereby enhancing the network's representational capacity and predictive performance and mitigating potential degradation in the network performance. Furthermore, an enhanced SE-GRU module was embedded in the skip connections to model and weight global information using an attention mechanism, capturing the temporal features of the PPG pulse signals through GRU layers to improve the quality of the transferred feature information and reduce redundant feature learning. Finally, a deep supervision mechanism was incorporated into the decoder module to guide the lower-level network to learn effective feature representations, alleviating the problem of gradient vanishing and facilitating effective training of the network. The proposed DSRUnet model was trained and tested on the publicly available UCI-BP dataset, with the average absolute errors for predicting systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean blood pressure (MBP) being 3.36 ± 6.61 mmHg, 2.35 ± 4.54 mmHg, and 2.21 ± 4.36 mmHg, respectively, meeting the standards set by the Association for the Advancement of Medical Instrumentation (AAMI), and achieving Grade A according to the British Hypertension Society (BHS) Standard for SBP and DBP predictions. Through ablation experiments and comparisons with other state-of-the-art methods, the effectiveness of DSRUnet in blood pressure prediction tasks, particularly for SBP, which generally yields poor prediction results, was significantly higher. The experimental results demonstrate that the DSRUnet model can accurately utilize PPG signals for real-time continuous blood pressure prediction and obtain high-quality and high-precision blood pressure prediction waveforms. Due to its non-invasiveness, continuity, and clinical relevance, the model may have significant implications for clinical applications in hospitals and research on wearable devices in daily life.


Subject(s)
Blood Pressure , Photoplethysmography , Humans , Photoplethysmography/methods , Blood Pressure/physiology , Algorithms , Signal Processing, Computer-Assisted , Neural Networks, Computer , Blood Pressure Determination/methods
3.
Sensors (Basel) ; 24(9)2024 May 03.
Article in English | MEDLINE | ID: mdl-38733031

ABSTRACT

This study aimed to propose a portable and intelligent rehabilitation evaluation system for digital stroke-patient rehabilitation assessment. Specifically, the study designed and developed a fusion device capable of emitting red, green, and infrared lights simultaneously for photoplethysmography (PPG) acquisition. Leveraging the different penetration depths and tissue reflection characteristics of these light wavelengths, the device can provide richer and more comprehensive physiological information. Furthermore, a Multi-Channel Convolutional Neural Network-Long Short-Term Memory-Attention (MCNN-LSTM-Attention) evaluation model was developed. This model, constructed based on multiple convolutional channels, facilitates the feature extraction and fusion of collected multi-modality data. Additionally, it incorporated an attention mechanism module capable of dynamically adjusting the importance weights of input information, thereby enhancing the accuracy of rehabilitation assessment. To validate the effectiveness of the proposed system, sixteen volunteers were recruited for clinical data collection and validation, comprising eight stroke patients and eight healthy subjects. Experimental results demonstrated the system's promising performance metrics (accuracy: 0.9125, precision: 0.8980, recall: 0.8970, F1 score: 0.8949, and loss function: 0.1261). This rehabilitation evaluation system holds the potential for stroke diagnosis and identification, laying a solid foundation for wearable-based stroke risk assessment and stroke rehabilitation assistance.


Subject(s)
Neural Networks, Computer , Photoplethysmography , Stroke Rehabilitation , Stroke , Humans , Stroke Rehabilitation/instrumentation , Stroke Rehabilitation/methods , Photoplethysmography/methods , Photoplethysmography/instrumentation , Stroke/physiopathology , Male , Female , Middle Aged , Adult , Plethysmography/methods , Plethysmography/instrumentation , Equipment Design , Wearable Electronic Devices , Algorithms
4.
Sensors (Basel) ; 24(10)2024 May 09.
Article in English | MEDLINE | ID: mdl-38793858

ABSTRACT

Inertial signals are the most widely used signals in human activity recognition (HAR) applications, and extensive research has been performed on developing HAR classifiers using accelerometer and gyroscope data. This study aimed to investigate the potential enhancement of HAR models through the fusion of biological signals with inertial signals. The classification of eight common low-, medium-, and high-intensity activities was assessed using machine learning (ML) algorithms, trained on accelerometer (ACC), blood volume pulse (BVP), and electrodermal activity (EDA) data obtained from a wrist-worn sensor. Two types of ML algorithms were employed: a random forest (RF) trained on features; and a pre-trained deep learning (DL) network (ResNet-18) trained on spectrogram images. Evaluation was conducted on both individual activities and more generalized activity groups, based on similar intensity. Results indicated that RF classifiers outperformed corresponding DL classifiers at both individual and grouped levels. However, the fusion of EDA and BVP signals with ACC data improved DL classifier performance compared to a baseline DL model with ACC-only data. The best performance was achieved by a classifier trained on a combination of ACC, EDA, and BVP images, yielding F1-scores of 69 and 87 for individual and grouped activity classifications, respectively. For DL models trained with additional biological signals, almost all individual activity classifications showed improvement (p-value < 0.05). In grouped activity classifications, DL model performance was enhanced for low- and medium-intensity activities. Exploring the classification of two specific activities, ascending/descending stairs and cycling, revealed significantly improved results using a DL model trained on combined ACC, BVP, and EDA spectrogram images (p-value < 0.05).


Subject(s)
Accelerometry , Algorithms , Machine Learning , Photoplethysmography , Humans , Photoplethysmography/methods , Accelerometry/methods , Male , Adult , Signal Processing, Computer-Assisted , Female , Human Activities , Galvanic Skin Response/physiology , Wearable Electronic Devices , Young Adult
5.
Dokl Biochem Biophys ; 516(1): 107-110, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38795243

ABSTRACT

The dynamics of the pulse wave (PW) associated with the PW transit time variability (PWTTV) determines the peripheral pulse rate variability, which is used as a surrogate for heart rate variability (HRV). The aim of the work is to analyze the frequency-dependent dynamics of PWTTV and to identify the possible frequency-phase modulation of PW velocity oscillations on the transit from the heart to the soft tissues of the distal parts of the upper extremities. RR-interval recordings and synchronous records of photoplethysmograms of 12 conditionally healthy subjects from the PhysioNet open database were used in this work. Using the Hilbert-Huang transform 3 spectral components of PWTTV and HRV were identified. It was shown that the amplitudes of PWTTV oscillations were many times (up to 8.4 times) smaller than the amplitudes of HRV, and the peaks of PWTTV spectral components were shifted towards higher frequencies than those of HRV. Functional relations between PWTTV and HRV, which can determine the phase modulation of periodic changes in the PW propagation velocity, were revealed.


Subject(s)
Heart Rate , Pulse Wave Analysis , Humans , Pilot Projects , Heart Rate/physiology , Male , Adult , Female , Photoplethysmography
6.
Biosensors (Basel) ; 14(5)2024 May 16.
Article in English | MEDLINE | ID: mdl-38785725

ABSTRACT

Peripheral artery disease (PAD) is a common circulatory disorder characterized by the accumulation of fats, cholesterol, and other substances in the arteries that restrict blood flow to the extremities, especially the legs. The ankle brachial index (ABI) is a highly reliable and valid non-invasive test for diagnosing PAD. However, the traditional method has limitations. These include the time required, the need for Doppler equipment, the training of clinical staff, and patient discomfort. PWV refers to the speed at which an arterial pressure wave propagates along the arteries, and this speed is conditioned by arterial elasticity and stiffness. To address these limitations, we have developed a system that uses electrocardiogram (ECG) and photoplethysmography (PPG) signals to calculate pulse wave velocity (PWV). We propose determining the ABI based on this calculation. Validation was performed on 22 diabetic patients, and the results demonstrate the accuracy of the system, maintaining a margin of ±0.1 compared with the traditional method. This confirms the correlation between PWV and ABI and positions this technique as a promising alternative to overcome some of the limitations of the conventional method.


Subject(s)
Ankle Brachial Index , Photoplethysmography , Pulse Wave Analysis , Humans , Peripheral Arterial Disease/diagnosis , Peripheral Arterial Disease/physiopathology , Electrocardiography , Male , Female , Middle Aged
7.
Physiol Meas ; 45(5)2024 May 28.
Article in English | MEDLINE | ID: mdl-38749458

ABSTRACT

Objective.Diagnosis of incipient acute hypovolemia is challenging as vital signs are typically normal and patients remain asymptomatic at early stages. The early identification of this entity would affect patients' outcome if physicians were able to treat it precociously. Thus, the development of a noninvasive, continuous bedside monitoring tool to detect occult hypovolemia before patients become hemodynamically unstable is clinically relevant. We hypothesize that pulse oximeter's alternant (AC) and continuous (DC) components of the infrared light are sensitive to acute and small changes in patient's volemia. We aimed to test this hypothesis in a cohort of healthy blood donors as a model of slight hypovolemia.Approach.We planned to prospectively study blood donor volunteers removing 450 ml of blood in supine position. Noninvasive arterial blood pressure, heart rate, and finger pulse oximetry were recorded. Data was analyzed before donation, after donation and during blood auto-transfusion generated by the passive leg-rising (PLR) maneuver.Main results.Sixty-six volunteers (44% women) accomplished the protocol successfully. No clinical symptoms of hypovolemia, arterial hypotension (systolic pressure < 90 mmHg), brady-tachycardia (heart rate <60 and >100 beats-per-minute) or hypoxemia (SpO2< 90%) were observed during donation. The AC signal before donation (median 0.21 and interquartile range 0.17 a.u.) increased after donation [0.26(0.19) a.u;p< 0.001]. The DC signal before donation [94.05(3.63) a.u] increased after blood extraction [94.65(3.49) a.u;p< 0.001]. When the legs' blood was auto-transfused during the PLR, the AC [0.21(0.13) a.u.;p= 0.54] and the DC [94.25(3.94) a.u.;p= 0.19] returned to pre-donation levels.Significance.The AC and DC components of finger pulse oximetry changed during blood donation in asymptomatic volunteers. The continuous monitoring of these signals could be helpful in detecting occult acute hypovolemia. New pulse oximeters should be developed combining the AC/DC signals with a functional hemodynamic monitoring of fluid responsiveness to define which patient needs fluid administration.


Subject(s)
Blood Donors , Fingers , Photoplethysmography , Humans , Pilot Projects , Female , Male , Adult , Fingers/blood supply , Hemorrhage/diagnosis , Middle Aged , Hypovolemia/diagnosis , Hypovolemia/physiopathology , Oximetry , Acute Disease , Young Adult , Heart Rate
8.
Biosensors (Basel) ; 14(4)2024 Apr 20.
Article in English | MEDLINE | ID: mdl-38667198

ABSTRACT

Wearable health devices (WHDs) are rapidly gaining ground in the biomedical field due to their ability to monitor the individual physiological state in everyday life scenarios, while providing a comfortable wear experience. This study introduces a novel wearable biomedical device capable of synchronously acquiring electrocardiographic (ECG), photoplethysmographic (PPG), galvanic skin response (GSR) and motion signals. The device has been specifically designed to be worn on a finger, enabling the acquisition of all biosignals directly on the fingertips, offering the significant advantage of being very comfortable and easy to be employed by the users. The simultaneous acquisition of different biosignals allows the extraction of important physiological indices, such as heart rate (HR) and its variability (HRV), pulse arrival time (PAT), GSR level, blood oxygenation level (SpO2), and respiratory rate, as well as motion detection, enabling the assessment of physiological states, together with the detection of potential physical and mental stress conditions. Preliminary measurements have been conducted on healthy subjects using a measurement protocol consisting of resting states (i.e., SUPINE and SIT) alternated with physiological stress conditions (i.e., STAND and WALK). Statistical analyses have been carried out among the distributions of the physiological indices extracted in time, frequency, and information domains, evaluated under different physiological conditions. The results of our analyses demonstrate the capability of the device to detect changes between rest and stress conditions, thereby encouraging its use for assessing individuals' physiological state. Furthermore, the possibility of performing synchronous acquisitions of PPG and ECG signals has allowed us to compare HRV and pulse rate variability (PRV) indices, so as to corroborate the reliability of PRV analysis under stationary physical conditions. Finally, the study confirms the already known limitations of wearable devices during physical activities, suggesting the use of algorithms for motion artifact correction.


Subject(s)
Electrocardiography , Fingers , Galvanic Skin Response , Heart Rate , Photoplethysmography , Wearable Electronic Devices , Humans , Monitoring, Physiologic/instrumentation , Signal Processing, Computer-Assisted , Male , Adult , Female
9.
Physiol Meas ; 45(5)2024 May 07.
Article in English | MEDLINE | ID: mdl-38604181

ABSTRACT

Objective. Monitoring changes in human heart rate variability (HRV) holds significant importance for protecting life and health. Studies have shown that Imaging Photoplethysmography (IPPG) based on ordinary color cameras can detect the color change of the skin pixel caused by cardiopulmonary system. Most researchers employed deep learning IPPG algorithms to extract the blood volume pulse (BVP) signal, analyzing it predominantly through the heart rate (HR). However, this approach often overlooks the inherent intricate time-frequency domain characteristics in the BVP signal, which cannot be comprehensively deduced solely from HR. The analysis of HRV metrics through the BVP signal is imperative. APPROACH: In this paper, the transformation invariant loss function with distance equilibrium (TIDLE) loss function is applied to IPPG for the first time, and the details of BVP signal can be recovered better. In detail, TIDLE is tested in four commonly used IPPG deep learning models, which are DeepPhys, EfficientPhys, Physnet and TS_CAN, and compared with other three loss functions, which are mean absolute error (MAE), mean square error (MSE), Neg Pearson Coefficient correlation (NPCC). MAIN RESULTS: The experiments demonstrate that MAE and MSE exhibit suboptimal performance in predicting LF/HF across the four models, achieving the Statistic of Mean Absolute Error (MAES) of 25.94% and 34.05%, respectively. In contrast, NPCC and TIDLE yielded more favorable results at 13.51% and 11.35%, respectively. Taking into consideration the morphological characteristics of the BVP signal, on the two optimal models for predicting HRV metrics, namely DeepPhys and TS_CAN, the Pearson coefficients for the BVP signals predicted by TIDLE in comparison to the gold-standard BVP signals achieved values of 0.627 and 0.605, respectively. In contrast, the results based on NPCC were notably lower, at only 0.545 and 0.533, respectively. SIGNIFICANCE: This paper contributes significantly to the effective restoration of the morphology and frequency domain characteristics of the BVP signal.


Subject(s)
Photoplethysmography , Signal Processing, Computer-Assisted , Photoplethysmography/methods , Humans , Deep Learning , Heart Rate/physiology , Algorithms , Image Processing, Computer-Assisted/methods
10.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38630867

ABSTRACT

AIMS: Photoplethysmography- (PPG) based smartphone applications facilitate heart rate and rhythm monitoring in patients with paroxysmal and persistent atrial fibrillation (AF). Despite an endorsement from the European Heart Rhythm Association, validation studies in this setting are lacking. Therefore, we evaluated the accuracy of PPG-derived heart rate and rhythm classification in subjects with an established diagnosis of AF in unsupervised real-world conditions. METHODS AND RESULTS: Fifty consecutive patients were enrolled, 4 weeks before undergoing AF ablation. Patients used a handheld single-lead electrocardiography (ECG) device and a fingertip PPG smartphone application to record 3907 heart rhythm measurements twice daily during 8 weeks. The ECG was performed immediately before and after each PPG recording and was given a diagnosis by the majority of three blinded cardiologists. A consistent ECG diagnosis was exhibited along with PPG data of sufficient quality in 3407 measurements. A single measurement exhibited good quality more often with ECG (93.2%) compared to PPG (89.5%; P < 0.001). However, PPG signal quality improved to 96.6% with repeated measurements. Photoplethysmography-based detection of AF demonstrated excellent sensitivity [98.3%; confidence interval (CI): 96.7-99.9%], specificity (99.9%; CI: 99.8-100.0%), positive predictive value (99.6%; CI: 99.1-100.0%), and negative predictive value (99.6%; CI: 99.0-100.0%). Photoplethysmography underestimated the heart rate in AF with 6.6 b.p.m. (95% CI: 5.8 b.p.m. to 7.4 b.p.m.). Bland-Altman analysis revealed increased underestimation in high heart rates. The root mean square error was 11.8 b.p.m. CONCLUSION: Smartphone applications using PPG can be used to monitor patients with AF in unsupervised real-world conditions. The accuracy of AF detection algorithms in this setting is excellent, but PPG-derived heart rate may tend to underestimate higher heart rates.


Subject(s)
Atrial Fibrillation , Humans , Atrial Fibrillation/diagnosis , Smartphone , Photoplethysmography , Heart Rate , Predictive Value of Tests , Electrocardiography/methods , Algorithms
11.
Sci Rep ; 14(1): 8145, 2024 04 08.
Article in English | MEDLINE | ID: mdl-38584229

ABSTRACT

Photoplethysmography (PPG) uses light to detect volumetric changes in blood, and is integrated into many healthcare devices to monitor various physiological measurements. However, an unresolved limitation of PPG is the effect of skin pigmentation on the signal and its impact on PPG based applications such as pulse oximetry. Hence, an in-silico model of the human finger was developed using the Monte Carlo (MC) technique to simulate light interactions with different melanin concentrations in a human finger, as it is the primary determinant of skin pigmentation. The AC/DC ratio in reflectance PPG mode was evaluated at source-detector separations of 1 mm and 3 mm as the convergence rate (Q), a parameter that quantifies the accuracy of the simulation, exceeded a threshold of 0.001. At a source-detector separation of 3 mm, the AC/DC ratio of light skin was 0.472 times more than moderate skin and 6.39 than dark skin at 660 nm, and 0.114 and 0.141 respectively at 940 nm. These findings are significant for the development of PPG-based sensors given the ongoing concerns regarding the impact of skin pigmentation on healthcare devices.


Subject(s)
Melanins , Photoplethysmography , Humans , Photoplethysmography/methods , Monte Carlo Method , Oximetry/methods , Fingers/physiology
12.
Sensors (Basel) ; 24(7)2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38610312

ABSTRACT

Electrocardiogram (ECG) reconstruction from contact photoplethysmogram (PPG) would be transformative for cardiac monitoring. We investigated the fundamental and practical feasibility of such reconstruction by first replicating pioneering work in the field, with the aim of assessing the methods and evaluation metrics used. We then expanded existing research by investigating different cycle segmentation methods and different evaluation scenarios to robustly verify both fundamental feasibility, as well as practical potential. We found that reconstruction using the discrete cosine transform (DCT) and a linear ridge regression model shows good results when PPG and ECG cycles are semantically aligned-the ECG R peak and PPG systolic peak are aligned-before training the model. Such reconstruction can be useful from a morphological perspective, but loses important physiological information (precise R peak location) due to cycle alignment. We also found better performance when personalization was used in training, while a general model in a leave-one-subject-out evaluation performed poorly, showing that a general mapping between PPG and ECG is difficult to derive. While such reconstruction is valuable, as the ECG contains more fine-grained information about the cardiac activity as well as offers a different modality (electrical signal) compared to the PPG (optical signal), our findings show that the usefulness of such reconstruction depends on the application, with a trade-off between morphological quality of QRS complexes and precise temporal placement of the R peak. Finally, we highlight future directions that may resolve existing problems and allow for reliable and robust cross-modal physiological monitoring using just PPG.


Subject(s)
Electrocardiography , Photoplethysmography , Feasibility Studies , Benchmarking , Electricity
13.
Sensors (Basel) ; 24(7)2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38610471

ABSTRACT

The adoption of telehealth has soared, and with that the acceptance of Remote Patient Monitoring (RPM) and virtual care. A review of the literature illustrates, however, that poor device usability can impact the generated data when using Patient-Generated Health Data (PGHD) devices, such as wearables or home use medical devices, when used outside a health facility. The Pi-CON methodology is introduced to overcome these challenges and guide the definition of user-friendly and intuitive devices in the future. Pi-CON stands for passive, continuous, and non-contact, and describes the ability to acquire health data, such as vital signs, continuously and passively with limited user interaction and without attaching any sensors to the patient. The paper highlights the advantages of Pi-CON by leveraging various sensors and techniques, such as radar, remote photoplethysmography, and infrared. It illustrates potential concerns and discusses future applications Pi-CON could be used for, including gait and fall monitoring by installing an omnipresent sensor based on the Pi-CON methodology. This would allow automatic data collection once a person is recognized, and could be extended with an integrated gateway so multiple cameras could be installed to enable data feeds to a cloud-based interface, allowing clinicians and family members to monitor patient health status remotely at any time.


Subject(s)
Gait , Photoplethysmography , Humans , Data Collection , Monitoring, Physiologic , Radar
14.
IEEE J Transl Eng Health Med ; 12: 328-339, 2024.
Article in English | MEDLINE | ID: mdl-38444399

ABSTRACT

OBJECTIVE: The aim of this study was to assess how the photoplethysmogram frequency and amplitude responses to arousals from sleep differ between arousals caused by apneas and hypopneas with and without blood oxygen desaturations, and spontaneous arousals. Stronger arousal causes were hypothesized to lead to larger and faster responses. METHODS AND PROCEDURES: Photoplethysmogram signal segments during and around respiratory and spontaneous arousals of 876 suspected obstructive sleep apnea patients were analyzed. Logistic functions were fit to the mean instantaneous frequency and instantaneous amplitude of the signal to detect the responses. Response intensities and timings were compared between arousals of different causes. RESULTS: The majority of the studied arousals induced photoplethysmogram responses. The frequency response was more intense ([Formula: see text]) after respiratory than spontaneous arousals, and after arousals caused by apneas compared to those caused by hypopneas. The amplitude response was stronger ([Formula: see text]) following hypopneas associated with blood oxygen desaturations compared to those that were not. The delays of these responses relative to the electroencephalogram arousal start times were the longest ([Formula: see text]) after arousals caused by apneas and the shortest after spontaneous arousals and arousals caused by hypopneas without blood oxygen desaturations. CONCLUSION: The presence and type of an airway obstruction and the presence of a blood oxygen desaturation affect the intensity and the timing of photoplethysmogram responses to arousals from sleep. CLINICAL IMPACT: The photoplethysmogram responses could be used for detecting arousals and assessing their intensity, and the individual variation in the response intensity and timing may hold diagnostically significant information.


Subject(s)
Photoplethysmography , Sleep Apnea, Obstructive , Humans , Sleep , Sleep Apnea, Obstructive/diagnosis , Arousal , Oxygen
15.
Physiol Meas ; 45(3)2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38430568

ABSTRACT

Objective. In previous studies, the factors affecting the accuracy of imaging photoplethysmography (iPPG) heart rate (HR) measurement have been focused on the light intensity, facial reflection angle, and motion artifacts. However, the factor of specularly reflected light has not been studied in detail. We explored the effect of specularly reflected light on the accuracy of HR estimation and proposed an estimation method for the direction of specularly radiated light.Approach. To study the HR measurement accuracy influenced by specularly reflected light, we control the component of specularly reflected light by controlling its angle. A total of 100 videos from four different reflected light angles were collected, and 25 subjects participated in the dataset collection. We extracted angles and illuminations for 71 facial regions, fitting sample points through interpolation, and selecting the angle corresponding to the maximum weight in the fitted curve as the estimated reflected angle.Main results. The experimental results show that higher specularly reflected light compromises HR estimation accuracy under the same value of light intensity. Notably, at a 60° angle, the HR accuracy (ACC) increased by 0.7%, while the signal-to-noise ratio and Pearson correlation coefficient increased by 0.8 dB and 0.035, respectively, compared to 0°. The overall root mean squared error, standard deviation, and mean error of our proposed reflected light angle estimation method on the illumination multi-angle incidence (IMAI) dataset are 1.173°, 0.978°, and 0.773°. The average Pearson value is 0.8 in the PURE rotation dataset. In addition, the average ACC of HR measurements in the PURE dataset is improved by 1.73% in our method compared to the state-of-the-art traditional methods.Significance. Our method has great potential for clinical applications, especially in bright light environments such as during surgery, to improve accuracy and monitor blood volume changes in blood vessels.


Subject(s)
Photoplethysmography , Signal Processing, Computer-Assisted , Humans , Heart Rate/physiology , Photoplethysmography/methods , Rotation , Artifacts , Algorithms
16.
Sensors (Basel) ; 24(5)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38475146

ABSTRACT

Various sensing modalities, including external and internal sensors, have been employed in research on human activity recognition (HAR). Among these, internal sensors, particularly wearable technologies, hold significant promise due to their lightweight nature and simplicity. Recently, HAR techniques leveraging wearable biometric signals, such as electrocardiography (ECG) and photoplethysmography (PPG), have been proposed using publicly available datasets. However, to facilitate broader practical applications, a more extensive analysis based on larger databases with cross-subject validation is required. In pursuit of this objective, we initially gathered PPG signals from 40 participants engaged in five common daily activities. Subsequently, we evaluated the feasibility of classifying these activities using deep learning architecture. The model's performance was assessed in terms of accuracy, precision, recall, and F-1 measure via cross-subject cross-validation (CV). The proposed method successfully distinguished the five activities considered, with an average test accuracy of 95.14%. Furthermore, we recommend an optimal window size based on a comprehensive evaluation of performance relative to the input signal length. These findings confirm the potential for practical HAR applications based on PPG and indicate its prospective extension to various domains, such as healthcare or fitness applications, by concurrently analyzing behavioral and health data through a single biometric signal.


Subject(s)
Neural Networks, Computer , Photoplethysmography , Humans , Photoplethysmography/methods , Prospective Studies , Electrocardiography/methods , Human Activities
17.
Sensors (Basel) ; 24(5)2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38475217

ABSTRACT

Age-related vessel deterioration leads to changes in the structure and function of the heart and blood vessels, notably stiffening of vessel walls, increasing the risk of developing cardiovascular disease (CVD), which accounts for 17.9 million global deaths annually. This study describes the fabrication of custom-made silicon vessels with varying mechanical properties (arterial stiffness). The primary objective of this study was to explore how changes in silicone formulations influenced vessel properties and their correlation with features extracted from signals obtained from photoplethysmography (PPG) reflectance sensors in an in vitro setting. Through alterations in the silicone formulations, it was found that it is possible to create elastomers exhibiting an elasticity range of 0.2 MPa to 1.22 MPa. It was observed that altering vessel elasticity significantly impacted PPG signal morphology, particularly reducing amplitude with increasing vessel stiffness (p < 0.001). A p-value of 5.176 × 10-15 and 1.831 × 10-14 was reported in the red and infrared signals, respectively. It has been concluded in this study that a femoral artery can be recreated using the silicone material, with the addition of a softener to achieve the required mechanical properties. This research lays the foundation for future studies to replicate healthy and unhealthy vascular systems. Additional pathologies can be introduced by carefully adjusting the elastomer materials or incorporating geometrical features consistent with various CVDs.


Subject(s)
Cardiovascular Diseases , Vascular Stiffness , Humans , Photoplethysmography , Silicones , Arteries , Elastomers
18.
Opt Lett ; 49(5): 1137-1140, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38426957

ABSTRACT

The work considers a theranostic system that implements a multimodal approach allowing the simultaneous generation of singlet oxygen and visualization of the various parameters of the vascular bed. The system, together with the developed data processing algorithm, has the ability to assess architectural changes in the vascular network and its blood supply, as well as to identify periodic signal changes associated with mechanisms of blood flow oscillation of various natures. The use of this system seems promising in studying the effect of laser-induced singlet oxygen on the state of the vascular bed, as well as within the framework of the theranostic concept of treatment and diagnosis of oncological diseases and non-oncological vascular anomalies.


Subject(s)
Precision Medicine , Singlet Oxygen , Photoplethysmography , Diagnostic Imaging , Lasers , Optical Imaging
19.
Physiol Meas ; 45(4)2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38530307

ABSTRACT

Objective. Atrial fibrillation (AF) is a prevalent cardiac arrhythmia associated with significant health ramifications, including an elevated susceptibility to ischemic stroke, heart disease, and heightened mortality. Photoplethysmography (PPG) has emerged as a promising technology for continuous AF monitoring for its cost-effectiveness and widespread integration into wearable devices. Our team previously conducted an exhaustive review on PPG-based AF detection before June 2019. However, since then, more advanced technologies have emerged in this field.Approach. This paper offers a comprehensive review of the latest advancements in PPG-based AF detection, utilizing digital health and artificial intelligence (AI) solutions, within the timeframe spanning from July 2019 to December 2022. Through extensive exploration of scientific databases, we have identified 57 pertinent studies.Significance. Our comprehensive review encompasses an in-depth assessment of the statistical methodologies, traditional machine learning techniques, and deep learning approaches employed in these studies. In addition, we address the challenges encountered in the domain of PPG-based AF detection. Furthermore, we maintain a dedicated website to curate the latest research in this area, with regular updates on a regular basis.


Subject(s)
Atrial Fibrillation , Wearable Electronic Devices , Humans , Atrial Fibrillation/diagnosis , Photoplethysmography , Artificial Intelligence , Machine Learning , Electrocardiography/methods
20.
Physiol Meas ; 45(4)2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38478997

ABSTRACT

Objective.Photoplethysmography is a non-invasive optical technique that measures changes in blood volume within tissues. It is commonly and being increasingly used for a variety of research and clinical applications to assess vascular dynamics and physiological parameters. Yet, contrary to heart rate variability measures, a field which has seen the development of stable standards and advanced toolboxes and software, no such standards and limited open tools exist for continuous photoplethysmogram (PPG) analysis. Consequently, the primary objective of this research was to identify, standardize, implement and validate key digital PPG biomarkers.Approach.This work describes the creation of a standard Python toolbox, denotedpyPPG, for long-term continuous PPG time-series analysis and demonstrates the detection and computation of a high number of fiducial points and digital biomarkers using a standard fingerbased transmission pulse oximeter.Main results.The improved PPG peak detector had an F1-score of 88.19% for the state-of-the-art benchmark when evaluated on 2054 adult polysomnography recordings totaling over 91 million reference beats. The algorithm outperformed the open-source original Matlab implementation by ∼5% when benchmarked on a subset of 100 randomly selected MESA recordings. More than 3000 fiducial points were manually annotated by two annotators in order to validate the fiducial points detector. The detector consistently demonstrated high performance, with a mean absolute error of less than 10 ms for all fiducial points.Significance.Based on these fiducial points,pyPPGengineered a set of 74 PPG biomarkers. Studying PPG time-series variability usingpyPPGcan enhance our understanding of the manifestations and etiology of diseases. This toolbox can also be used for biomarker engineering in training data-driven models.pyPPGis available onhttps://physiozoo.com/.


Subject(s)
Photoplethysmography , Signal Processing, Computer-Assisted , Heart Rate/physiology , Photoplethysmography/methods , Polysomnography , Algorithms , Biomarkers