Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.945
Filter
1.
Article in English | MEDLINE | ID: mdl-38727533

ABSTRACT

Preoperative calculations showed that the 9-mm inlet, 6-mm outlet, 25-cc pump chambers and 65-73 bpm would be optimal for a 5-year-old patient suffering from restrictive cardiomyopathy, with a body surface area of 0.59 m2 (1.5 L/min flow for a cardiac index of 2.5). After re-sternotomy and standard bicaval cannulation for cardiopulmonary bypass, the procedure was performed under normothermic conditions and on the beating heart. Biventricular support was established with the Berlin Heart Excor using biatrial cannulation. For left atrial cannulation, induced ventricular fibrillation was used. The 9-mm inlet cannulas were inserted into the left and right atria, respectively. The 6-mm outlet cannulas were implanted using 8-mm interposition vascular grafts for the aorta and the main pulmonary artery, respectively. Cannulas were tunnelled through the epigastric space, with systems crossing outside of the body. The 25-cc chambers were used for both right ventricular assist device and left ventricular assist device support, which subsequently showed full emptying and filling.


Subject(s)
Cardiomyopathy, Restrictive , Heart-Assist Devices , Humans , Cardiomyopathy, Restrictive/surgery , Cardiomyopathy, Restrictive/diagnosis , Male , Child, Preschool , Heart Atria/surgery , Cardiac Catheterization/methods , Cardiac Catheterization/instrumentation , Heart Failure/surgery , Prosthesis Implantation/methods
2.
Otolaryngol Pol ; 78(3): 1-5, 2024 Jun 30.
Article in English | MEDLINE | ID: mdl-38808636

ABSTRACT

<b><br>Introduction:</b> In an era of wide accessibility to various systems for hearing impairment prosthetics, there exists a broad spectrum of surgical techniques facilitating system implantation.</br> <b><br>Aim:</b> The aim of the study is to present the technique of vertical incision in the implantation of the Baha Attract magnetic system as an alternative incision, maintaining a compromise between optimizing the surgical procedure and preserving the functionality and quality of life of the patient.</br> <b><br>Materials and methods:</b> The vertical incision technique is presented based on 5 patients treated between December 2022 and March 2023 diagnosed with conductive or mixed hearing loss.</br> <b><br>Results:</b> There were no adverse consequences or complications resulting from the performed surgical incision. All patients experienced uncomplicated healing. Patients are using sound processor magnets ranging from 4-5 in strength and Baha<sup></sup> 6 Max sound processors weighing 11.5 g.</br> <b><br>Conclusions:</b> The vertical incision technique serves as an alternative to the C-shaped perimeter incision, allowing for the optimization and standardization of the surgical procedure, resulting in a smooth scar formation and maintaining good audiological and aesthetic outcomes.</br>.


Subject(s)
Hearing Aids , Humans , Female , Male , Adult , Hearing Loss, Conductive/surgery , Middle Aged , Prosthesis Implantation/methods , Treatment Outcome
3.
Int J Cardiol ; 407: 132113, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38697398

ABSTRACT

BACKGROUND: Axillary vein puncture (AVP) is a valid alternative to Subclavan vein puncture for leads insertion in cardiac implantable electronic device implantation, that may reduce acute and delayed complications. Very few data are available about ICD recipients. A simplified AVP technique is described. METHODS: All the patients who consecutively underwent "de novo" ICD implantation, from March 2006 to December 2020 at the University of Verona, were considered. Leads insertion was routinely performed through an AVP, according to a simplified technique. Outcome and complications have been retrospectively analyzed. RESULTS: The study population consisted of 1711 consecutive patients. Out of 1711 patients, 38 (2.2%) were excluded because they were implanted with Medtronic Sprint Fidelis lead. Out of 1673 ICD implantations, 963 (57.6%) were ICD plus cardiac resynchronization therapy, 434 (25.9%) were dual-chamber defibrillators, and 276 (16.5%) were single-chamber defibrillators, for a total of 3879 implanted leads. The AVP success rate was 99.4%. Acute complications occurred in 7/1673 (0.42%) patients. Lead failure (LF) occurred in 20/1673 (1.19%) patients. Comparing the group of patients with lead failure with the group without LF, the presence of three leads inside the vein was significantly associated with LF, and the multivariate analysis confirmed three leads in place as an independent predictor of LF. CONCLUSION: AVP, according to our simplified technique, is safe, effective, has a high success rate, and a very low complication rate. The incidence of LF was exceptionally low. The advantages of AVP are maintained over time in a population of ICD recipients.


Subject(s)
Axillary Vein , Defibrillators, Implantable , Punctures , Humans , Defibrillators, Implantable/adverse effects , Male , Female , Retrospective Studies , Aged , Middle Aged , Axillary Vein/diagnostic imaging , Prosthesis Implantation/methods , Prosthesis Implantation/adverse effects , Prosthesis Implantation/instrumentation , Treatment Outcome , Time Factors
4.
Otol Neurotol ; 45(5): 556-563, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38693091

ABSTRACT

OBJECTIVE: To investigate the feasibility of early sound processor loading with two separate bone-anchored hearing aid implants 1 to 2 weeks after implantation. Secondary endpoints included registration of any postoperative complications, skin reactions, and any adverse events. STUDY DESIGN: Prospective, nonrandomized, noncontrolled, multicenter clinical trial. SETTING: Tertiary referral center. PATIENTS: Sixty adult patients, eligible for bone-anchored hearing aid surgery, were enrolled. INTERVENTION: Implantation of the bone-anchored hearing aid implants were done using minimally invasive surgery with tissue preservation. MAIN OUTCOME MEASURE: Implant stability quotient (ISQ) values were recorded using resonance frequency analysis. Follow-ups were scheduled 5 to 12 days, 4 to 8 weeks, 6 months, and 12 months postoperatively. Differences between the lowest ISQ values (ISQ low) over time were analyzed by paired-samples t test with a significance level of 0.05. Skin and soft tissue reactions were assessed according to Holger's classification. RESULTS: Loading time of the Ponto Wide implant was 11.6 ± 1.4 days (SD) in average (median, 12 d; range, 7-19 d). Loading of the Ponto BHX implant was done 9.7 ± 3.5 days (SD) postoperatively (median, 9 d; range, 5-19 d). The implant stability increased significantly during the 12-month study period with both implants. One Ponto BHX implant was lost. Skin and soft tissue reactions were few in both groups. Across all planned follow-up visits, no skin and soft tissue reactions were observed in 86% (Ponto BHX implant) and 85% (Ponto Wide implant). CONCLUSION: Very early loading of sound processors after percutaneous bone-anchored hearing system surgery is safe already 1 to 2 weeks postoperatively.


Subject(s)
Hearing Aids , Humans , Male , Female , Middle Aged , Adult , Aged , Prospective Studies , Treatment Outcome , Suture Anchors , Bone-Anchored Prosthesis , Prosthesis Implantation/methods , Young Adult , Aged, 80 and over
5.
J Orthop Surg Res ; 19(1): 273, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38698477

ABSTRACT

BACKGROUND: Talar malignant tumor is extremely rare. Currently, there are several alternative management options for talus malignant tumor including below-knee amputation, tibio-calcaneal arthrodesis, and homogenous bone transplant while their shortcomings limited the clinical application. Three-dimensional (3D) printed total talus prosthesis in talus lesion was reported as a useful method to reconstruct talus, however, most researches are case reports and its clinical effect remains unclear. Therefore, the current study was to explore the application of 3D printed custom-made modular prosthesis in talus malignant tumor. METHODS: We retrospectively analyzed the patients who received the 3D printed custom-made modular prosthesis treatment due to talus malignant tumor in our hospital from February 2016 to December 2021. The patient's clinical data such as oncology outcome, operation time, and volume of blood loss were recorded. The limb function was evaluated with the Musculoskeletal Tumor Society 93 (MSTS-93) score, The American Orthopedic Foot and Ankle Society (AOFAS) score; the ankle joint ranges of motion as well as the leg length discrepancy were evaluated. Plain radiography and Tomosynthesis-Shimadzu Metal Artefact Reduction Technology (T-SMART) were used to evaluate the position of prosthesis and the osseointegration. Postoperative complications were recorded. RESULTS: The average patients' age and the follow-up period were respectively 31.5 ± 13.1 years; and 54.8 months (range 26-72). The medium operation time was 2.4 ± 0.5 h; the intraoperative blood loss was 131.7 ± 121.4 ml. The mean MSTS-93 and AOFAS score was 26.8 and 88.5 respectively. The average plantar flexion, dorsiflexion, varus, and valgus were 32.5, 9.2, 10.8, and 5.8 degree respectively. One patient had delayed postoperative wound healing. There was no leg length discrepancy observed in any patient and good osseointegration was observed on the interface between the bone and talus prosthesis in all subjects. CONCLUSION: The modular structure of the prosthesis developed in this study seems to be convenient for prosthesis implantation and screws distribution. And the combination of solid and porous structure improves the initial stability and promotes bone integration. Therefore, 3D printed custom-made modular talus prosthesis could be an alternative option for talus reconstruction in talus malignant tumor patients.


Subject(s)
Bone Neoplasms , Printing, Three-Dimensional , Prosthesis Design , Talus , Humans , Talus/surgery , Talus/diagnostic imaging , Male , Adult , Female , Bone Neoplasms/surgery , Bone Neoplasms/diagnostic imaging , Retrospective Studies , Middle Aged , Young Adult , Prosthesis Implantation/methods , Prosthesis Implantation/instrumentation , Adolescent , Ankle Joint/surgery , Ankle Joint/diagnostic imaging , Osseointegration , Treatment Outcome , Range of Motion, Articular , Prostheses and Implants
6.
Isr Med Assoc J ; 26(5): 278-282, 2024 May.
Article in English | MEDLINE | ID: mdl-38736341

ABSTRACT

BACKGROUND: Long-term support with a HeartMate 3 (HM3) left ventricular assist device (LVAD) has improved outcomes of patients with end-stage heart failure. However, there is a paucity of data on the outcomes of patients who underwent concomitant cardiac surgical procedure (CCSP) during HM3-LVAD implantation. OBJECTIVES: To assess our single-center experience with patients who underwent CCSP during the implantation of an HM3-LVAD. METHODS: From December 2016 until April 2022, 131 adult patients underwent HM3-LVAD implantation. A total of 23 patients underwent CCSP during the HM3-LVAD implantation+CCSP, and 108 underwent only HM3-LVAD implantation (HM3-only). RESULTS: The median age was 59 ± 11 years (range 54-67), 82% (n=108) were male, and 76% (n=100) were implanted as a bridge-to-transplant. The concomitant procedures performed during the implantation included 8 aortic valve repairs/replacements, 14 tricuspid valve repairs, 4 patent foramen ovales or atrial septal defect closures, and 3 other cardiac procedures. The mean cardiopulmonary bypass time was 113 ± 58 minutes for the HM3-only group and 155 ± 47 minutes for the HM3+CCSP group (P = 0.007). The mortality rates at 30 days, 6 months, and 12 months post-implantation were 2 (9%), 5 (22%), and 6 (26%) respectively for the HM3+CCSP group, and 7 (6%), 18 (17%), and 30 (28%) for the HM3-only group (P = 0.658, 0.554, and 1.000). CONCLUSIONS: Our experience demonstrated no significant difference in the 30-day, 6-month, and 12-month mortality rates for patients who underwent a CCSP during HM3-LVAD implantation compared to patients who did not undergo CCSP during HM3-LVAD implantation.


Subject(s)
Cardiac Surgical Procedures , Heart Failure , Heart-Assist Devices , Humans , Heart-Assist Devices/statistics & numerical data , Male , Female , Middle Aged , Heart Failure/surgery , Heart Failure/mortality , Heart Failure/therapy , Aged , Cardiac Surgical Procedures/methods , Retrospective Studies , Treatment Outcome , Prosthesis Implantation/methods
7.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Article in Russian | MEDLINE | ID: mdl-38742501

ABSTRACT

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Subject(s)
Contact Lenses , Keratoconus , Sclera , Visual Acuity , Humans , Keratoconus/surgery , Keratoconus/diagnosis , Keratoconus/physiopathology , Keratoconus/therapy , Female , Male , Adult , Sclera/surgery , Prosthesis Implantation/methods , Prosthesis Implantation/instrumentation , Treatment Outcome , Corneal Topography , Prostheses and Implants , Young Adult , Prosthesis Fitting/methods , Adolescent , Corneal Stroma/surgery
9.
Indian J Ophthalmol ; 72(Suppl 3): S495-S500, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38648457

ABSTRACT

PURPOSE: This retrospective longitudinal study evaluated the biomechanical E-staging in KC corneas before and after intracorneal ring segment (ICRS) implantation (Intacs® SK, Addition Technology, Illinois, United States). METHODS: Biomechanical E-staging for ectatic corneal diseases was applied retrospectively on 49 KC corneas of 41 patients who underwent ICRS implantation. The main outcome parameters included the Corvis Biomechanical Factor (CBiF, the linearized Corvis Biomechanical Index and the biomechanical parameters included), the resulting biomechanical E-staging, the stress-strain index, thinnest corneal thickness (TCT), maximal anterior keratometry (Kmax), and the anterior radius of curvature (ARC). They were evaluated at 1.9 ± 1.1 months preoperatively and postoperatively after 2.8 ± 0.7, 5.8 ± 1.0, and 10.6 ± 2.3 months. RESULTS: The CBiF decreased (4.9 ± 0.5 | 4.7 ± 0.5, P = 0.0013), and the E-staging increased significantly (2.8 ± 0.8 | 3.1 ± 0.9, P = 0.0012, paired t-test) from preoperatively to the first postoperative follow-up. The difference remained significant after 6 months; however, there was no more difference after 11 months. TCT was stable, whereas Kmax and ARC significantly decreased after ICRS implantation (TCT: 464 ± 49, 470 ± 51, 467 ± 38, 461 ± 48; Kmax: 56.3 ± 4.5, 54.7 ± 4.5, 54.2 ± 4.8, 54.1 ± 4.3; ARC: 51.5 ± 3.4, 48.3 ± 3.8, 48.6 ± 3.0, 48.6 ± 3.2 preoperatively and 3, 6, and 11 months postoperatively, respectively). Besides Kmax and ARC, Ambrósio's relational thickness to the horizontal profile (ARTh) was the only parameter that was significantly lower than preoperatively at any follow-up (P ≤ 0.0024, Wilcoxon matched-pairs test). CONCLUSION: Intacs® SK implantation results in an increasing biomechanical E-staging in the first postoperative months with stabilization near preoperative values after 1 year. Significantly lower ARTh values at any follow-up document the ICRS effect and contribute to a slightly higher postoperative biomechanical E-staging value.


Subject(s)
Cornea , Corneal Stroma , Corneal Topography , Keratoconus , Prostheses and Implants , Prosthesis Implantation , Visual Acuity , Humans , Keratoconus/surgery , Keratoconus/diagnosis , Keratoconus/physiopathology , Retrospective Studies , Female , Male , Adult , Prosthesis Implantation/methods , Cornea/pathology , Follow-Up Studies , Corneal Stroma/pathology , Corneal Stroma/surgery , Visual Acuity/physiology , Biomechanical Phenomena , Young Adult , Middle Aged , Refraction, Ocular/physiology , Prosthesis Design , Adolescent
10.
Arq Bras Oftalmol ; 87(6): e2021, 2024.
Article in English | MEDLINE | ID: mdl-38597522

ABSTRACT

Implantation of glaucoma drainage devices is a valuable therapeutic option, particularly in children with glaucoma refractory to primary surgical treatment. Glaucoma drainage devices are typically used when conjunctival scarring hampers filtration surgery or prior angle procedures are not effective in controlling intraocular pressure. Despite known complications, the use of glaucoma drainage devices in children has increased in recent years, even as the primary surgical option. In this review, we evaluate the results of recent studies involving the implantation of glaucoma drainage devices in children, discussing new advances, and comparing the success rates and complications of different devices.


Subject(s)
Conjunctival Diseases , Glaucoma Drainage Implants , Glaucoma , Child , Humans , Glaucoma Drainage Implants/adverse effects , Glaucoma/surgery , Intraocular Pressure , Prosthesis Implantation/methods , Retrospective Studies , Treatment Outcome
11.
Arq Bras Oftalmol ; 87(4): e2022, 2024.
Article in English | MEDLINE | ID: mdl-38656019

ABSTRACT

We present a case report detailing the successful phacoemulsification surgery with artificial iris implantation for two individuals with oculocutaneous albinism. These women suffered from cataracts, resulting in reduced visual acuity and heightened photophobia due to iris pigmentary epithelium deficiency. The patients underwent phacoemulsification along with prosthetic artificial iris implantation into the posterior chamber. This intervention resulted in improved visual acuity, reduced photophobia and glare, and an overall enhanced quality of life. Our report highlights two cases of successful phacoemulsification and artificial iris implantation in patients with oculocutaneous albinism and cataracts, leading to improved visual acuity, reduced photophobia, and enhanced quality of life. Notably, there are no prior records in South American literature of cataract surgery combined with artificial iris implantation for oculocutaneous albinism patients up to the time of this publication.


Subject(s)
Albinism, Oculocutaneous , Iris , Phacoemulsification , Visual Acuity , Humans , Albinism, Oculocutaneous/surgery , Albinism, Oculocutaneous/complications , Female , Iris/surgery , Phacoemulsification/methods , Treatment Outcome , Cataract/complications , Cataract/congenital , Quality of Life , Adult , Artificial Organs , Prosthesis Implantation/methods , Middle Aged , Photophobia/surgery , Photophobia/etiology
13.
Arch Ital Urol Androl ; 96(1): 12214, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38572722

ABSTRACT

INTRODUCTION AND OBJECTIVES: Artificial urinary sphincter (AUS) is a treatment option for women with stress urinary incontinence (SUI) after failure of previous surgery or as a primary procedure in severe intrinsic sphincter deficiency (ISD). The aim of the study was to assess the long-term efficacy and risk factors for surgical revision and definitive explantation of AUS laparoscopic implantation in female patients. METHODS: A retrospective review of all women submitted to AUS implantation between April 2005 and March 2023 was conducted. The AUS was implanted via transperitoneal laparoscopic approach, by two experienced surgeons. The primary endpoint was postoperative continence. Continence was defined as no leakage and no pad usage or leakage and/or pad usage with no impact on social life and failure as leakage and/or pad usage impacting social life. As secondary outcomes, clinical predictive factors for AUS revision and definitive explantation were evaluated. RESULTS: In the last 18 years, females with a mean age of 68±12 years-old were submitted to laparoscopic implantation of AUS. Early overall complication rate was 16%, but only one case was Clavien-Dindo ≥3. After a median follow-up of 67 months, 22.2% of the patients needed a device revision, the majority due to mechanical device dysfunction. AUS definitive explantation was performed in 16%, mainly due to urethral/vaginal erosion (9.9%) and infection (6.2%). Patients with age ≥70 years and follow-up ≥10 years significantly predisposed for device revision. At the time of the last follow-up, 72% of the patients were keeping the urinary continency. CONCLUSIONS: Laparoscopic AUS implantation in females is an effective treatment for SUI due to ISD. Meanwhile, adequate patient selection, multidisciplinary evaluation and careful expectation management are essential to achieving good results, concerning their significant complication rate.


Subject(s)
Laparoscopy , Urethral Diseases , Urinary Incontinence, Stress , Urinary Sphincter, Artificial , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Urinary Sphincter, Artificial/adverse effects , Treatment Outcome , Urinary Incontinence, Stress/surgery , Urinary Incontinence, Stress/etiology , Laparoscopy/adverse effects , Urethra/surgery , Urethral Diseases/surgery , Prosthesis Implantation/methods , Retrospective Studies
14.
J Orthop Surg Res ; 19(1): 210, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38561755

ABSTRACT

OBJECTIVE: This study aims to biomimetic design a new 3D-printed lattice hemipelvis prosthesis and evaluate its clinical efficiency for pelvic reconstruction following tumor resection, focusing on feasibility, osseointegration, and patient outcomes. METHODS: From May 2020 to October 2021, twelve patients with pelvic tumors underwent tumor resection and subsequently received 3D-printed lattice hemipelvis prostheses for pelvic reconstruction. The prosthesis was strategically incorporated with lattice structures and solid to optimize mechanical performance and osseointegration. The pore size and porosity were analyzed. Patient outcomes were assessed through a combination of clinical and radiological evaluations. RESULTS: Multiple pore sizes were observed in irregular porous structures, with a wide distribution range (approximately 300-900 µm). The average follow-up of 34.7 months, ranging 26 from to 43 months. One patient with Ewing sarcoma died of pulmonary metastasis 33 months after surgery while others were alive at the last follow-up. Postoperative radiographs showed that the prosthesis's position was consistent with the preoperative planning. T-SMART images showed that the host bone was in close and tight contact with the prosthesis with no gaps at the interface. The average MSTS score was 21 at the last follow-up, ranging from 18 to 24. There was no complication requiring revision surgery or removal of the 3D-printed hemipelvis prosthesis, such as infection, screw breakage, and prosthesis loosening. CONCLUSION: The newly designed 3D-printed lattice hemipelvis prosthesis created multiple pore sizes with a wide distribution range and resulted in good osteointegration and favorable limb function.


Subject(s)
Bone Neoplasms , Pelvic Neoplasms , Humans , Prosthesis Design , Biomimetics , Titanium , Prosthesis Implantation/methods , Pelvic Neoplasms/surgery , Bone Neoplasms/diagnostic imaging , Bone Neoplasms/surgery , Bone Neoplasms/pathology , Retrospective Studies , Treatment Outcome , Printing, Three-Dimensional
15.
Sci Rep ; 14(1): 5867, 2024 03 11.
Article in English | MEDLINE | ID: mdl-38467756

ABSTRACT

To illustrate the surgical technique and explore clinical outcomes of the reconstruction for the malignant and metastatic bone tumour of proximal femur with metallic modular intercalary prosthesis. Sixteen patients who underwent modular intercalary prosthetic reconstruction after tumour resection were included from April 2012 and October 2020. Prosthesis and screws parameters, resected bone length and residual bone length, clinical outcomes and survivorship were analyzed. All patients were followed up for an average of 19 months (range 1-74). In our series, 12 patients died of the progression of the primary disease at the final follow-up. The cumulative survivorship since the treatment of proximal femoral metastasis was 78.6% (11 patients) at 6 months and 38.5% (5 patients) at 1 year. The mean MSTS score was 22.25 ± 4.55 among all patients. There were no cases of loosening or breakage of the prostheses, plates or screws, despite the various measurements of prostheses and residual bones. Modular intercalary prosthetic reconstruction was an effective method for malignant tumour of the proximal femur, including the advantages of providing early pain relief, quickly restoring postoperative function, required a short operation time, and preserving the adjacent joints.


Subject(s)
Bone Neoplasms , Femur , Humans , Treatment Outcome , Femur/pathology , Lower Extremity , Prosthesis Implantation/methods , Bone Neoplasms/pathology , Retrospective Studies
16.
Artif Organs ; 48(6): 655-664, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38459775

ABSTRACT

OBJECTIVES: Right ventricular failure following implantation of a durable left ventricular assist device (LVAD) is a major driver of mortality. Reported survival following biventricular (BiVAD) or total artificial heart (TAH) implantation remains substantially inferior to LVAD alone. We report our outcomes with LVAD and BiVAD HeartMate 3 (HM3). METHODS: Consecutive patients undergoing implantation of an HM3 LVAD between November 2014 and December 2021, at The Alfred, Australia were included in the study. Comparison was made between the BiVAD and LVAD alone groups. RESULTS: A total of 86 patients, 65 patients with LVAD alone and 21 in a BiVAD configuration underwent implantation. The median age of the LVAD and BiVAD groups was 56 years (Interquartile range 46-62) and 49 years (Interquartile range 37-55), respectively. By 4 years after implantation, 54% of LVAD patients and 43% of BiVAD patients had undergone cardiac transplantation. The incidence of stroke in the entire experience was 3.5% and pump thrombosis 5% (all in the RVAD). There were 14 deaths in the LVAD group and 1 in the BiVAD group. The actuarial survival for LVAD patients at 1 year was 85% and BiVAD patients at 1 year was 95%. CONCLUSIONS: The application of HM 3 BiVAD support in selected patients appears to offer a satisfactory solution to patients requiring biventricular support.


Subject(s)
Heart Failure , Heart-Assist Devices , Humans , Middle Aged , Male , Female , Heart Failure/surgery , Heart Failure/mortality , Heart Failure/therapy , Adult , Retrospective Studies , Treatment Outcome , Heart Transplantation/methods , Australia/epidemiology , Prosthesis Implantation/instrumentation , Prosthesis Implantation/adverse effects , Prosthesis Implantation/methods
17.
Pacing Clin Electrophysiol ; 47(4): 496-502, 2024 04.
Article in English | MEDLINE | ID: mdl-38462721

ABSTRACT

BACKGROUND: Inappropriate shock (IAS) caused by subcutaneous air entrapment (AE) in an early period after subcutaneous implantable cardioverter defibrillator (S-ICD) implantation has been reported, however, no detailed data on air volume are available. We evaluated the subcutaneous air volume after implantation and its absorption rate one week after implantation. METHODS: Patients who underwent S-ICD implantation in our hospital received chest CT scans immediately after implantation and followed up 1 week later. The total subcutaneous air volume, air around the generator, the distal electrode, and the proximal electrode within 3 cm were calculated using a three-dimensional workstation. Fat areas at the level of the lower edge of the generator were also analyzed. RESULT: Fifteen patients received CT immediately after implantation. The mean age was 45.6 ± 17.9 (66.7% of men), and the mean body mass index was 24.3 ± 3.3. The three-incision technique was applied in seven patients and two-incision technique was in the latter eight patients. The mean total subcutaneous air volume was 18.54 ± 7.50 mL. Air volume around the generator, the distal electrode, and the proximal electrode were 11.05 ± 5.12, 0.72 ± 0.72, and 0.88 ± 0.87 mL, respectively. Twelve patients received a follow-up CT 1 week later. The mean total subcutaneous air was 0.25 ± 0.45 mL, showing a 98.7% absorption rate. CONCLUSION: Although subcutaneous air was observed in all patients after S-ICD implantation, most of the air was absorbed within 1 week, suggesting a low occurrence of AE-related IAS after a week postoperation.


Subject(s)
Defibrillators, Implantable , Male , Humans , Adult , Middle Aged , Defibrillators, Implantable/adverse effects , Electric Countershock , Prosthesis Implantation/adverse effects , Prosthesis Implantation/methods , Tomography, X-Ray Computed , Tomography , Treatment Outcome
18.
Acta Ophthalmol ; 102(4): e443-e451, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38376121

ABSTRACT

To compare the safety and efficacy of the Preserflo Microshunt with trabeculectomy in the treatment of patients with glaucoma. A systematic review and meta-analysis was conducted. The primary outcome measures recorded as a measure of efficacy of the interventions were intra-ocular pressure (IOP) at final follow-up and IOP reduction (IOPR). Secondary outcomes recorded to measure efficacy were reduction in the number of glaucoma medications and reinterventions. To assess safety profile, the proportions of patients with post-operative complications were recorded. Seven articles were included in this study. A total of 1353 eyes were included in this review (Preserflo: 812, trabeculectomy: 541). Post-operative IOP (mean difference [MD] = 0.78 [0.66, 0.90], p < 0.001) results are significantly lower for trabeculectomy than Preserflo. The IOPR (MD = -1.20 [-2.30, -0.09], p = 0.034) results significantly favour trabeculectomy over Preserflo Microshunt. The reduction in topical glaucoma medications (MD = -0.32 [-0.58, -0.07], p = 0.014) is significantly higher for trabeculectomy. There is no statistically significant difference in levels of hypotony (risk ratio [RR] = -0.05 [-0.47, 0.37], p = 0.806), choroidal effusion/detachment (RR = -0.12 [-0.42, 0.19], p = 0.444), hyphaema (RR = 0.20 [-0.11, 0.51], p = 0.216) and flat anterior chamber (RR = 0.49 [-1.02, 0.03], p = 0.066). There are significantly more bleb-related complications in the trabeculectomy groups than Preserflo groups (RR = -0.63 [-1.01, -0.24], p = 0.001). There were statistically more reinterventions required in the trabeculectomy groups than Preserflo groups (RR = -0.48 [-0.65, -0.30], p < 0.001). Compared to trabeculectomy, the Preserflo Microshunt is not as effective in lowering intra-ocular pressure, has a similar safety profile and has a lower reintervention rate. Further research is required given the lack of randomised controlled trials within this study and resulting low strength of evidence.


Subject(s)
Glaucoma , Intraocular Pressure , Trabeculectomy , Humans , Glaucoma/surgery , Glaucoma/physiopathology , Glaucoma Drainage Implants , Hyaluronic Acid/administration & dosage , Intraocular Pressure/physiology , Prosthesis Implantation/methods , Trabeculectomy/methods , Treatment Outcome
19.
Ophthalmologie ; 121(4): 298-307, 2024 Apr.
Article in German | MEDLINE | ID: mdl-38363380

ABSTRACT

BACKGROUND: The eyeWatch System (EWS) (Rheon Medical, Lausanne, Switzerland) was developed as a glaucoma drainage device (GDD) to precisely control intraocular pressure (IOP) and thus prevent the development of postoperative hypotension and its complications. OBJECTIVE: To report 1­year outcomes from a single-center cohort undergoing EWS surgery. MATERIAL AND METHODS: Retrospective review of patients undergoing EWS surgery at the University Eye Hospital Bonn, Germany from May 2021 to September 2022. RESULTS: A total of 5 eyes of the first 5 consecutive patients treated with the EWS were included in this study. The mean preoperative IOP was 34.6 mm Hg (23-45 mm Hg) which was reduced to 12.2 mm Hg (9-18 mm Hg) with a mean reduction of 60%. Local pressure-lowering therapy was reduced from 2.8 agents preoperatively (1-4) to 0.6 agents after 1 year. All patients achieved the target IOP of below 21 mm Hg including 4 patients without any medication. The complication rate was low. One patient had to undergo two surgical revisions as the IOP was elevated to over 30 mm Hg after surgery and tube exposure became apparent during the course of the follow-up so that a second donor patch was sutured on. The same patient had an elevated IOP >30 mm Hg after a cMRI examination, so that a reduction of IOP by adjusting the EWS using the eyeWatch pen (EWP) was performed. IOP adjustments with the eyeWatch pen (EWP) were performed in 4 of 5 patients in the first year after surgery; the mean IOP before adjustment was 21.33 mm Hg (15-37 mm Hg) which was reduced to a mean of 8.58 mm Hg (4-16 mm Hg). CONCLUSION: The EWS effectively lowers IOP and the amount of necessary pressure-lowering therapy. With the EWP postoperative adjustments of IOP are possible without further invasive measures.


Subject(s)
Glaucoma , Prosthesis Implantation , Humans , Treatment Outcome , Prosthesis Implantation/methods , Postoperative Complications/surgery , Glaucoma/surgery , Intraocular Pressure
20.
PLoS One ; 19(2): e0288181, 2024.
Article in English | MEDLINE | ID: mdl-38319899

ABSTRACT

OBJECTIVES: To identify predictive factors and to construct predictive models using epidemiological and clinical preoperative factors for the visual acuity change after intracorneal ring segment (ICRS) implantation in patients with keratoconus. METHODS: The medical records of 287 keratoconic eyes of 230 patients implanted with ICRS at Chula Refractive Surgery Center of a tertiary university hospital (Bangkok, Thailand) between January 2012 and March 2022 were retrospectively reviewed for epidemiological and clinical preoperative variables, including those derived from Scheimpflug tomography. After randomly excluding one eye for each bilateral case, the remaining 230 eyes were randomized into two groups: a training group (184 eyes) and a validation group (46 eyes). In the training group, the correlation between the interesting variables and postoperative uncorrected and corrected distance visual acuity change (ΔUDVA and ΔCDVA; logMAR scale) at 6 months was explored, and then the multiple linear regression analysis was used to develop the predictive models. The obtained models were tested using the validation group. RESULTS: There were 5 and 14 preoperative variables that statistically correlated with ΔUDVA and ΔCDVA respectively. Only the preoperative corrected distance visual acuity (CDVAp) strongly correlated with ΔCDVA (Beta = -0.746). Using multiple regression, the preoperative uncorrected distance visual acuity (UDVAp) and front mean keratometry were selected in the proposed model for ΔUDVA (adjusted R2 = 38.8%), while the CDVAp and index of surface variance (ISV) were selected in the model [Formula: see text] (adjusted R2 = 48.9%). The ΔUDVA and ΔCDVA models were correct in 47.83% and 63.4% of the validation group within 0.20 logMAR, respectively. CONCLUSIONS: Potential predictive factors and models for ICRS-induced changes in visual acuity are proposed as adjunctive tools for clinicians. Such tools could be used for case selection and during counselling before ICRS implantation to maximize surgical outcomes.


Subject(s)
Keratoconus , Humans , Corneal Stroma/surgery , Corneal Topography , Eye, Artificial , Keratoconus/surgery , Prostheses and Implants , Prosthesis Implantation/methods , Refraction, Ocular , Retrospective Studies , Thailand
SELECTION OF CITATIONS
SEARCH DETAIL
...