Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.918
Filter
1.
Interv Cardiol Clin ; 13(3): 369-384, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38839170

ABSTRACT

Over the last 2 decades, experience with transcatheter pulmonary valve replacement (TPVR) has grown significantly and has become an effective and reliable way of treating pulmonary valve regurgitation, right ventricular outflow (RVOT) obstruction, and dysfunctional bioprosthetic valves and conduits. With the introduction of self-expanding valves and prestents, dilated native RVOT can be addressed with the transcatheter approach. In this article, the authors review the current practices, technical challenges, and outcomes of TPVR.


Subject(s)
Cardiac Catheterization , Heart Defects, Congenital , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Pulmonary Valve/surgery , Heart Defects, Congenital/surgery , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/diagnosis , Ventricular Outflow Obstruction/surgery , Prosthesis Design , Bioprosthesis
2.
Sultan Qaboos Univ Med J ; 24(2): 276-278, 2024 May.
Article in English | MEDLINE | ID: mdl-38828236

ABSTRACT

Blood-filled cysts of the heart valves are frequently reported at postpartum autopsies of infants. They are seen as round nodules mostly in the paediatric age group in infants less than 2 months of age and disappear spontaneously within 6 months of life. We report a unique case of an 11-month-old girl who presented at a tertiary healthcare hospital in 2022 with a blood-filled cyst on the posterior leaflet of the pulmonary valve that was successfully treated. This case report highlights the characteristics and course of a paediatric patient with blood-filled cysts. Further studies are yet needed to better understand the diagnostic approaches to blood-filled cysts as well as treatment modalities to fill the gap in clinical settings.


Subject(s)
Cysts , Female , Humans , Infant , Cysts/congenital , Pulmonary Valve/abnormalities
3.
BMC Cardiovasc Disord ; 24(1): 301, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38872098

ABSTRACT

BACKGROUND: Studies of transcatheter pulmonary valve replacement (TPVR) with the Melody valve have demonstrated good clinical and hemodynamic outcomes. Our study analyzes the midterm clinical and hemodynamic outcomes for patients who underwent Melody valve implantation in Southeast Asia. METHODS: Patients with circumferential conduits or bioprosthetic valves and experiencing post-operative right ventricular outflow tract (RVOT) dysfunction were recruited for Melody TPVR. RESULTS: Our cohort (n = 14) was evenly divided between pediatric and adult patients. The median age was 19 years (8-38 years), a male-to-female ratio of 6:1 with a median follow-up period of 48 months (16-79 months), and the smallest patient was an 8-year-old boy weighing 18 kg. All TPVR procedures were uneventful and successful with no immediate mortality or conduit rupture. The primary implant indication was combined stenosis and regurgitation. The average conduit diameter was 21 ± 2.3 mm. Concomitant pre-stenting was done in 71.4% of the patients without Melody valve stent fractures (MSFs). Implanted valve size included 22-mm (64.3%), 20-mm (14.3%), and 18-mm (21.4%). After TPVR, the mean gradient across the RVOT was significantly reduced from 41 mmHg (10-48 mmHg) to 16 mmHg (6-35 mmHg) at discharge, p < 0.01. Late follow-up infective endocarditis (IE) was diagnosed in 2 patients (14.3%). Overall freedom from IE was 86% at 79 months follow-up. Three patients (21.4%) developed progressive RVOT gradients. CONCLUSION: For patients in Southeast Asia with RVOT dysfunction, Melody TPVR outcomes are similar to those reported for patients in the US in terms of hemodynamic and clinical improvements. A pre-stenting strategy was adopted and no MSFs were observed. Post-implantation residual stenosis and progressive stenosis of the RVOT require long term monitoring and reintervention. Lastly, IE remained a concern despite vigorous prevention and peri-procedural bacterial endocarditis prophylaxis.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Pulmonary Valve , Recovery of Function , Humans , Male , Child , Female , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Adolescent , Pulmonary Valve/surgery , Pulmonary Valve/physiopathology , Pulmonary Valve/diagnostic imaging , Treatment Outcome , Young Adult , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Time Factors , Adult , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/diagnostic imaging , Bioprosthesis , Pulmonary Valve Stenosis/surgery , Pulmonary Valve Stenosis/physiopathology , Pulmonary Valve Stenosis/diagnostic imaging , Retrospective Studies , Risk Factors , Asia, Southeastern
4.
Rev. esp. cardiol. (Ed. impr.) ; 77(5): 408-417, mayo 2024. ilus, tab, graf
Article in Spanish | IBECS | ID: ibc-JHG-74

ABSTRACT

Introducción y objetivos: Evaluar el impacto del recambio valvular pulmonar (RVP) en pacientes con tetralogía de Fallot reparada (TFr) en la evolución de los volúmenes y función b-ventricular, y en los eventos adversos.MétodosSe identificó adultos con TFr del registro SACHER. Se evaluó los datos seriados de cardiorresonancia magnética, ecocardiografía, capacidad de ejercicio y fracción aminoterminal del propéptido natriurético cerebral (tipo B) (NT-proBNP). El objetivo primario fue la fracción de eyección del ventrículo derecho (FEVD) medida por cardiorresonancia. Los objetivos secundarios fueron volúmenes biventriculares, capacidad de ejercicio, valores de NT-proBNP y tiempo hasta eventos adversos (arritmia auricular o ventricular, endocarditis). Se analizó las asociaciones entre el RVP previo y las trayectorias longitudinales de los resultados funcionales, y el tiempo hasta los eventos cardiacos adversos con modelos lineales de efectos mixtos y modelos de riesgos proporcionales de Cox, respectivamente.ResultadosSe analizó a 308 pacientes (153 con y 155 sin RVP) con 887 visitas de estudio. No se asoció el RVP de manera significativa con la trayectoria de la FEVD (CE=-1,33; IC95%, –5,87-3,21; p=0,566). Se asoció el RVP previo con menor volumen telediastólico del ventrículo derecho, pero no tuvo efecto significativo en la fracción de eyección del ventrículo izquierdo, capacidad de ejercicio o valores de NT-proBNP. Se asoció el RVP previo con un riesgo incrementado de arritmias auriculares (HR=2,09; IC95%, 1,17-3,72; p=0,012) y endocarditis infecciosa (HR=12,72; IC95%, 4,69-34,49; p<0,0001), pero no con un riesgo aumentado de arritmias ventriculares sostenidas (HR=0,64; IC95%, 0,18-2,27; p=0,490).ConclusionesNo se asoció el RVP previo de manera significativa con la trayectoria de la FEVD, pero sí con un riesgo aumentado de arritmias auriculares y endocarditis infecciosa. (AU)


Introduction and objectives: Our aim was to assess the impact of prosthetic pulmonary valve replacement (PVR) in patients with repaired tetralogy of Fallot (rTOF) on changes in biventricular volumes and function and on adverse cardiac events.MethodsAdults with rTOF were identified from the SACHER-registry. Data from serial cardiac magnetic resonance imaging, echocardiography, exercise capacity and n-terminal pro b-type natriuretic peptide (NT-proBNP) were collected. The primary endpoint was right ventricular ejection fraction (RVEF) as measured by cardiac magnetic resonance. Secondary endpoints were biventricular volumes, left ventricular ejection fraction, exercise capacity and NT-proBNP levels, and time to adverse cardiac outcomes (atrial and ventricular arrhythmia, endocarditis). Associations between previous PVR and longitudinal changes in functional outcomes and time to adverse cardiac outcomes were analyzed using linear mixed-effects models and Cox proportional hazards models, respectively.ResultsA total of 308 patients (153 with and 155 without PVR) with 887 study visits were analyzed. Previous PVR was not significantly associated with changes in RVEF (CE, -1.33; 95%CI, -5.87 to 3.21; P=.566). Previous PVR was associated with lower right ventricular end-diastolic volume but had no significant effect on left ventricular ejection fraction, exercise capacity, or NT-proBNP-levels. Previous PVR was associated with an increased hazard of atrial arrhythmias (HR, 2.09; 95%CI, 1.17-3.72; P=.012) and infective endocarditis (HR, 12.72; 95%CI, 4.69-34.49; P<.0001) but not with an increased hazard of sustained ventricular arrhythmias (HR, 0.64; 95%CI, 0.18-2.27; P=.490).ConclusionsPrevious PVR was not significantly associated with changes in RVEF but was associated with an increased risk of atrial arrhythmias and infective endocarditis. (AU)


Subject(s)
Humans , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Echocardiography , Natriuretic Peptides/blood , Pulmonary Valve/surgery , Follow-Up Studies , Stroke Volume/physiology
5.
J Cardiothorac Surg ; 19(1): 288, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38745263

ABSTRACT

Pulmonary arterial sarcomas (PAS) are rare aggressive tumours occurring mainly in the pulmonary trunk. We report a case of PAS involving the pulmonary trunk wall and valve, with uniform wall thickening which represents an atypical imaging manifestation of this tumour. A 63-year-old male presented with vague respiratory symptoms with rapid progression. CTPA showed low density filling defects in both pulmonary arteries and PET scan showed increased uptake in the pulmonary trunk, which along with raised ESR suggested Pulmonary Vasculitis. Echo imaging showed Right ventricular hypertrophy and pulmonary stenosis. Response to steroid therapy was minimal and his symptoms worsened. A referral for second opinion was made and he was diagnosed with PAS. He underwent Pulmonary thromboendarterectomy with Pulmonary valve replacement. Post-operative histopathology confirmed the diagnosis. PAS is rare and frequently misdiagnosed. Surgical resection is not curative, but together with chemotherapy can prolong survival.


Subject(s)
Pulmonary Artery , Pulmonary Valve , Sarcoma , Vascular Neoplasms , Humans , Male , Middle Aged , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Pulmonary Artery/pathology , Sarcoma/diagnosis , Sarcoma/surgery , Pulmonary Valve/diagnostic imaging , Vascular Neoplasms/diagnosis , Vascular Neoplasms/surgery , Vascular Neoplasms/diagnostic imaging , Diagnosis, Differential , Vasculitis/diagnosis , Diagnostic Errors
6.
Sci Rep ; 14(1): 12318, 2024 05 29.
Article in English | MEDLINE | ID: mdl-38811656

ABSTRACT

Partial heart transplantation (PHT) is a novel surgical approach that involves transplantation of only the part of the heart containing a valve. The rationale for this approach is to deliver growing heart valve implants that reduce the need for future re-operations in children. However, prior to clinical application of this approach, it was important to assess it in a preclinical model. To investigate PHT short-term outcomes and safety, we performed PHT in a piglet model. Yorkshire piglets (n = 14) were used for PHT of the pulmonary valve. Donor and recipient pairs were matched based on blood types. The piglets underwent PHT at an average age of 44 days (range 34-53). Post-operatively, the piglets were monitored for a period of two months. Of the 7 recipient piglets, one mortality occurred secondary to anesthesia complications while undergoing a routine echocardiogram on post-operative day 19. All piglets had appropriate weight gain and laboratory findings throughout the post-operative period indicating a general state of good health and rehabilitation after undergoing PHT. We conclude that PHT has good short-term survival in the swine model. PHT appears to be safe for clinical application.


Subject(s)
Heart Transplantation , Animals , Heart Transplantation/methods , Heart Transplantation/adverse effects , Swine , Pulmonary Valve/surgery , Models, Animal , Disease Models, Animal
7.
Comput Biol Med ; 176: 108604, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38761502

ABSTRACT

OBJECTIVE: In young patients, aortic valve disease is often treated by placement of a pulmonary autograft (PA) which adapts to its new environment through growth and remodeling. To better understand the hemodynamic forces acting on the highly distensible PA in the acute phase after surgery, we developed a fluid-structure interaction (FSI) framework and comprehensively compared hemodynamics and wall shear-stress (WSS) metrics with a computational fluid dynamic (CFD) simulation. METHODS: The FSI framework couples a prestressed non-linear hyperelastic arterial tissue model with a fluid model using the in-house coupling code CoCoNuT. Geometry, material parameters and boundary conditions are based on in-vivo measurements. Hemodynamics, time-averaged WSS (TAWSS), oscillatory shear index (OSI) and topological shear variation index (TSVI) are evaluated qualitatively and quantitatively for 3 different sheeps. RESULTS: Despite systolic-to-diastolic volumetric changes of the PA in the order of 20 %, the point-by-point correlation of TAWSS and OSI obtained through CFD and FSI remains high (r > 0.9, p < 0.01) for TAWSS and (r > 0.8, p < 0.01) for OSI). Instantaneous WSS divergence patterns qualitatively preserve similarities, but large deformations of the PA leads to a decrease of the correlation between FSI and CFD resolved TSVI (r < 0.7, p < 0.01). Moderate co-localization between FSI and CFD is observed for low thresholds of TAWSS and high thresholds of OSI and TSVI. CONCLUSION: FSI might be warranted if we were to use the TSVI as a mechano-biological driver for growth and remodeling of PA due to varying intra-vascular flow structures and near wall hemodynamics because of the large expansion of the PA.


Subject(s)
Hemodynamics , Models, Cardiovascular , Pulmonary Artery , Hemodynamics/physiology , Pulmonary Artery/physiology , Pulmonary Artery/physiopathology , Hydrodynamics , Animals , Humans , Computer Simulation , Pulmonary Valve/surgery , Pulmonary Valve/physiology , Autografts , Stress, Mechanical
10.
JACC Cardiovasc Interv ; 17(9): 1079-1090, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38749587

ABSTRACT

Tetralogy of Fallot (TOF) is the most common form of cyanotic congenital heart disease. Palliative procedures, either surgical or transcatheter, aim to improve oxygen saturation, affording definitive procedures at a later stage. Transcatheter interventions have been used before and after surgical palliative or definitive repair in children and adults. This review aims to provide an overview of the different catheter-based interventions for TOF across all age groups, with an emphasis on palliative interventions, such as patent arterial duct stenting, right ventricular outflow tract stenting, or balloon pulmonary valvuloplasty in infants and children and transcatheter pulmonary valve replacement in adults with repaired TOF, including the available options for a large, dilated native right ventricular outflow tract.


Subject(s)
Balloon Valvuloplasty , Cardiac Catheterization , Heart Valve Prosthesis Implantation , Palliative Care , Stents , Tetralogy of Fallot , Humans , Tetralogy of Fallot/surgery , Tetralogy of Fallot/diagnostic imaging , Tetralogy of Fallot/physiopathology , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Infant , Treatment Outcome , Age Factors , Child, Preschool , Child , Adult , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Adolescent , Infant, Newborn , Young Adult , Cardiac Surgical Procedures/adverse effects , Risk Factors , Female , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Pulmonary Valve/physiopathology , Male , Hemodynamics , Middle Aged , Recovery of Function
11.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38569760

ABSTRACT

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Adult , Pulmonary Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects , Treatment Outcome , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/etiology , Registries , Prosthesis Design , Retrospective Studies
12.
Pediatr Transplant ; 28(3): e14746, 2024 May.
Article in English | MEDLINE | ID: mdl-38566335

ABSTRACT

INTRODUCTION: Partial heart transplants are a new type of pediatric transplant that replace defective heart valves with the parts of matched donor hearts containing the necessary valves. Short-term outcomes of partial heart transplants are excellent, but long-term outcomes are unknown. In order to predict the long-term outcomes of partial heart transplants, we evaluated long-term growth and function of semilunar heart valves transplanted in infancy as part of a heart transplant. METHODS: All children who underwent infant heart transplantation at a single center from 1997 to 2014 were included in this study. Children in whom echocardiograms after heart transplantation and after 10 years were not available for review were excluded. The echocardiograms were reviewed by two authors to analyze semilunar valve annulus diameters, Z-scores, peak valve gradients, and valve regurgitation. Statistical difference was determined using two-tailed, paired sample t-tests with Bonferroni correction for multiple comparisons. RESULTS: Data from 15 patients were analyzed. The aortic valve annulus averaged 1.3 cm (range 0.7-1.8 cm) immediately after transplantation and grew to an average of 1.7 cm (range 1.4-2.3 cm) after 10 years (p < .001). After 10 years, the aortic valve peak gradient avereraged 5.1 mmHg (range 2.1-15.5 mmHg) and none of the valves had more than trivial regurgitation. The pulmonary valve annulus averaged 1.5 cm (range 1.1-2.5 cm) immediately after transplantation and grew to an average of 2.1 cm (range 1.0-2.9 cm) after 10 years (p < .001). After 10 years, the pulmonary valve peak gradient averaged 4.3 mmHg (range 1.1-13.8 mmHg), and 7% of valves had moderate regurgitation. DISCUSSION: Semilunar heart valves transplanted in infancy as part of a heart transplant demonstrate statistically significant growth and excellent function after 10 years. This predicts excellent long-term outcomes of partial heart transplants.


Subject(s)
Heart Transplantation , Pulmonary Valve , Infant , Child , Humans , Aortic Valve/diagnostic imaging , Tissue Donors , Echocardiography , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/transplantation
14.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Article in English | MEDLINE | ID: mdl-38597297

ABSTRACT

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Subject(s)
Cardiac Catheterization , Finite Element Analysis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Models, Cardiovascular , Patient-Specific Modeling , Prosthesis Design , Pulmonary Valve , Humans , Pulmonary Valve/physiopathology , Pulmonary Valve/surgery , Pulmonary Valve/diagnostic imaging , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Risk Assessment , Adolescent , Treatment Outcome , Risk Factors , Male , Child , Retrospective Studies , Female , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Young Adult , Predictive Value of Tests , Hemodynamics , Stents , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Ventricular Outflow Obstruction/physiopathology , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/diagnostic imaging , Clinical Decision-Making , Adult
15.
Circ Cardiovasc Interv ; 17(5): e013889, 2024 May.
Article in English | MEDLINE | ID: mdl-38606564

ABSTRACT

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Prosthesis Design , Pulmonary Valve , Humans , Pulmonary Valve/surgery , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Treatment Outcome , Male , Female , Adolescent , Young Adult , Child , Adult , Retrospective Studies , Predictive Value of Tests , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/diagnostic imaging , Patient Selection , Clinical Decision-Making , Recovery of Function , Hemodynamics
17.
Thorac Cardiovasc Surg ; 72(S 03): e1-e6, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38688313

ABSTRACT

BACKGROUND: In patients with tetralogy of Fallot (ToF) or ToF-like anatomy, factors possibly impacting the longevity of biological valves in the pulmonary position were investigated. METHOD: Between 1997 and 2017, 79 consecutive hospital survivors with a median age of 8.7 years (range: 0.2-56.1 years; interquartile range [IQR]: 14.8 years) with ToF or ToF-like anatomy underwent surgical implantation of Contegra (n = 34), Hancock (n = 23), Perimount (n = 9), pulmonary homograft (n = 9), and miscellaneous (n = 4) conduits. The median internal graft diameter was 19 mm (range: 11-29 mm; IQR: 8 mm) which refers to a median z-score of 0.6 standard deviation (SD) (range: -1.8 to 4.0 SD; IQR: 2.1 SD). RESULTS: The median time of follow-up was 9.4 years (range: 1.1-18.8 years; IQR: 6.0 years). Thirty-nine patients (49%) underwent surgical (n = 32) or interventional (n = 7) pulmonary valve re-replacement. Univariate Cox regression revealed patient age (p = 0.018), body surface area (p = 0.004), internal valve diameter (p = 0.005), and prosthesis z-score (p = 0.018) to impact valve longevity. Multivariate Cox regression analysis, however, did not show any significant effect (likely related to multicollinearity). Subgroup analysis showed that valve-revised patients have a higher average z-score (p = 0.003) and younger average age (p = 0.007). CONCLUSION: A decreased longevity of biological valves in the pulmonary position is related to younger age, lower valve diameter, and higher z-score. Because valve size (diameter and z-score) can be predicted by age, patient age is the crucial parameter influencing graft longevity.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Prosthesis Design , Pulmonary Valve , Tetralogy of Fallot , Humans , Pulmonary Valve/surgery , Pulmonary Valve/physiopathology , Pulmonary Valve/diagnostic imaging , Male , Female , Adult , Young Adult , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Time Factors , Middle Aged , Adolescent , Infant , Risk Factors , Treatment Outcome , Child , Child, Preschool , Tetralogy of Fallot/surgery , Tetralogy of Fallot/physiopathology , Retrospective Studies , Age Factors , Prosthesis Failure , Risk Assessment , Reoperation
20.
Article in English | MEDLINE | ID: mdl-38522870

ABSTRACT

Half a century after the first pulmonary autograft operation (Ross operation), performed in 1967 by Donald Ross in central London, there is a very strong conviction that the Ross operation is the best available valve substitute today, not only for children, but also for younger and older adults. The Ross operation has stimulated a lot of science to do with tissue-engineering and biology of heart valves, which is a promising avenue for the future. For one of us (M.Y.), it has certainly been a privilege to be associated with the comeback of the Ross operation.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Pulmonary Valve , Child , Humans , Aged , Autografts/surgery , Pulmonary Valve/surgery , Transplantation, Autologous , Reoperation , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...